Test Report to AS/NZS :2015. Report No. T160402_S

Similar documents
SLIP RESISTANCE TESTING OF ENDURO-MESH PANEL

Test Report. Appliance EMF Testing

Test Report for the determination of Critical Fall Height for Under Playground Surfacing with Plants

SAIME. KaleidoSeries. 300x300,300x600,600x600&450x900mm Mat(R10CP4),Roc(R12P5)&Lappato. Bianco Beige Avorio. Cappucino Cenere Fango.

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

WITH OMRON E5CC CONTROL

NEUTRAL SALT SPRAY TESTING REPORT TEST RESULTS. Kim Bray Materials Testing Officer AUTHORISED SIGNATORY. Bureau Veritas

REFRIGERATED RECIRCULATORY COOLER

Fire resistance test on fire collars protecting a concrete slab penetrated by services

FIRE-RESISTANCE TEST ON FIRE COLLARS PROTECTING A PLASTERBOARD WALL PENETRATED BY SERVICES

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

CERTIFICATION SAFETY & BEYOND

OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN

OPERATING INSTRUCTIONS FOR:

LABORATORY ILLUMINATED FLOTATION BATH

Infrastructure Technology

OPERATION & MAINTENANCE INSTRUCTIONS FOR. 230/240 VAC, 1ø, 50Hz

FIRE-RESISTANCE TEST ON DOWNLIGHT COVERS INSTALLED IN PLASTERBOARD CEILINGS

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

Australian Standard. Electroacoustics Sound calibrators AS IEC This is a free 7 page sample. Access the full version online.

Engineering Report Vibration Test for Intertek Testing Services Prepared by Approved by 9725 Girard Avenue South Minneapolis, MN 55431

Clipsal Integrated Systems International Representatives China Head Office Greece Hong Kong South Africa Offices in all States Taiwan NSW VIC

Classification of Fire Performance of Wall and Ceiling Lining Materials

Australian Standard. Functional safety of electrical/electronic/programmable electronic safety-related systems. Part 0: Functional safety and AS 61508

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Australian/New Zealand Standard

Developments in Australian Standard AS (Emergency Lighting)

AS/NZS :1995. Emergency escape lighting and exit signs for buildings AS/NZS :1995. Part 2: Inspection and maintenance

CERTIFICATE. Issued Date: Dec. 23, 2010 Report No.: 10C142R-ITCEP7V05

AS/NZS IEC :2015

Sound Pressure Level Test Report Report No. : PH2_09_ Date : 2009/6/30

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Test report no.: Plug and key - Damp heat test

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Australian/New Zealand Standard

The Icon Series. User Guide. CDV25 Version 1.0. Iconopm1.pm

Australian/New Zealand Standard

AS/NZS TR IEC :2012

OPPORTUNITY IS STEADILY GROWING.

AS/NZS :2008

GUARDIAN FIRE TESTING LABORATORIES, INC.

Changes to Certification and its Impact on Manufacturers. Des McDonell CSE-Ex Pty Ltd

Security Alarm System Owner's Guide 8 sector CDS Dialler 8-24 sector Control Dialler 8-24 sector Control Securitel Version 1.0 lcopm.

for LABORATORY REFRIGERATOR MODEL TELR-145/ L/200L CAPACITY REVISION

Drawer fronts: 16 mm particleboard Doors: 16 mm particleboard This report covers the models Nonstop, Sprinter, Genese

C-Bus Black & White MK II Desktop Touchscreen. 5000CTD2 Series. User s Guide REGISTERED DESIGN REGISTERED PATENT

AS/NZS 3133:2008 AS/NZS

OPERATING INSTRUCTIONS

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL

GBC BLIZZARD A4 & A3 Laminators. Instruction Manual

WARRANTY BOOKLET. Commercial Hot Water. Register online at

Australian Standard. Emergency escape lighting and exit signs for buildings. Part 1: System design, installation and operation AS 2293.

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 21: Particular requirements Rigid conduit systems

Australian Standard. Fire protection for mobile and transportable equipment AS AS

Australian/New Zealand Standard

Australian/New Zealand Standard

Australian/New Zealand Standard

AS/NZS 3820:2009 (Incorporating Amendment 1) Essential safety requirements for electrical equipment

M1C. Operator Manual

WARRANTY BOOKLET. EHPA Electric Heat Pump Water Heaters. Register online at

AS/NZS 4012:1999 AS/NZS

Michael J. Caron, Test Engineer. Lee R. Senne, Test Technician. Kent L. Erickson, Dynamics Division Manager

Australian Standard. Closed circuit television (CCTV) Part 4: Remote video AS AS

EVOLVE AWARDS 2010 ENTRY PACK

Push Button Electronic Timer. 31VETR Series. Installation Instructions

WARRANTY BOOKLET. Hotflo (HFE) Series. Electric Storage Water Heaters. Register online at

DCP3/ DETAILS OF THE CLIENT ADDRESS OF THE INSTALLATION

WARRANTY BOOKLET. Solar Hot Water. Register online at

AS AS Australian Standard. Potting mixes. This is a free 7 page sample. Access the full version online.

BUSHFIRE TEST ON GLAZED VERTICAL ELEMENTS

Session Four Functional safety: the next edition of IEC Mirek Generowicz Engineering Manager, I&E Systems Pty Ltd

Emergency Management Plan

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. FCC MPE REPORT

Patrick Port Botany Container Terminal Biannual Environmental Noise Compliance Monitoring May 2017

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CERTIFICATE. Issued Date: Apr. 16, 2014 Report No. : R-ITCEP11V04

Ultrasonic Clamp-On Flow Meter Testing

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

August 2013 Technical Requirements for Remote Controlled Temporary Traffic Management Signs for use on the Highways Agency Strategic Road Network

Australian/New Zealand Standard

Southern California Gas Company Customer Programs Department

HTA ACCREDITATIONS. NADCAP (Heat Treating) 2 AS 9100C 5-6 ISO NADCAP (Heat Treating) 3 AS 9100C 5-6 ISO NADCAP (Heat Treating) 4

AS/NZS :2009

GE Security. Proven. Powerful. Integrated fire and life safety solutions.

Emergency. Management. Emergency. Readiness Checklist

Australian/New Zealand Standard

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

1.7L KETTLE INSTRUCTION MANUAL 220~240V 2200W

AS/NZS :2009. Performance of household electrical appliances Refrigerating appliances AS/NZS :2009

Australian/New Zealand Standard

NOVALED. The Revolutionary downlight is re-powered

Report No.: SQE Page 2 of 11 Issued: Test Report No. : EMC -- T E S T R E P O R T SQE Equipment under Test : 24Bit Barometer

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

WYLE LABORATORIES, INC. Huntsville Facility

OPERATING INSTRUCTIONS

Transcription:

Page 1 of 6 EMC Technologies Pty Ltd ABN 82 057 105 549 Unit 3/87 Station Road Seven Hills NSW 2147 Australia Telephone +61 2 9624 2777 Facsimile +61 2 9838 4050 Email sales@emctech.com.au Test Report to AS/NZS 60950.1:2015 Report No. T160402_S Manufacturer: ITS Manufacturing, Roads and Maritime Services Test Sample Name: CBD Evacuation System Model: CBD 2007 Serial No.: N/A Date of Issue: 12 th April, 2016 EMC Technologies Pty Ltd reports apply only to the specific samples tested under stated test conditions. It is the manufacturer s responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. EMC Technologies Pty Ltd shall have no liability for any deductions; interferences or generalisations drawn by the client or others from EMC Technologies Pty Ltd issued reports. This report shall not be used to claim, constitute or imply product endorsement by EMC Technologies Pty Ltd. Accredited for compliance with ISO/IEC 17025. The results of tests, calibration and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced except in full, with the exception of the Certificate of Compliance on Page 2. Melbourne 176 Harrick Road Keilor Park Vic 3042 Tel: +61 3 9365 1000 Fax: +61 3 9331 7455 Sydney Unit 3/87 Station Road Seven Hills NSW 2147 Tel: +61 2 9624 2777 Fax: +61 2 9838 4050 Auckland (NZ) 47 MacKelvie Street Grey Lynn Auckland Tel: +64 9 360 0862 Fax: +64 9 360 0861

EMC Technologies Report No.T160402_S Page 2 of 6 EMC Technologies Report No.: T160402_S Test Sample Name: CBD Evacuation System Model: CBD 2007 Serial Number: N/A Part Number: N/A Manufacturer: ITS Manufacturing, Roads and Maritime Services Tested For: Address: ITS Manufacturing, Roads and Maritime Services 129a Orchardleigh Street, Yennora, NSW 2161, Australia Phone: +61 2 9794 4765 Fax: +61 2 9794 4894 Responsible Party: ITS Manufacturing, Roads and Maritime Services Contact: Steven Wang Test Standard/s: AS/NZS 60950.1:2015 Information technology equipment Safety Part 1: General requirements Result of Test: Power consumption of test samples were measured according to clause 1.6.2 of AS/NZS 60950.1:2015. Refer to Report no. T160402_S for full details. Test Date/s: 8 th April, 2016 Testing Officer: James Chu Authorised Signature: James Chu Safety Manager EMC Technologies Pty Ltd Issued by EMC Technologies Pty Ltd, Unit 3/87 Station Road, Seven Hills, NSW, 2147, Australia. Phone: +61 2 9624 2777 Fax: +61 2 9838 4050

EMC Technologies Report No.T160402_S Page 3 of 6 PRODUCT DESCRIPTION SUMMARY The equipment under test is an evacuation system. It consists of a display sign (Variable Message Sign Mono Single Line 15Ch, VMS Code: VMS-M-1-15) and a loudspeaker system (Wireless Announcement Unit, Unit Code: COMRW01 supplied by Open Access Pty Ltd). Both parts were tested individually in this report. TEST EQUIPMENT: The following test equipment were used during the tests. All instruments within their specified calibration periods and traceable to Australian national standards of measurement. Equipment Make/Model Measurements Calibration due date Power analyser Clarke-hess 2330 Input voltage, current, frequency, power factor and power 30 th November, 2016 Mains break out box EMCT B016 None (for connections only) -- Variac ISKRA V03 None (for voltage adjustment only) -- Isolating transformer EMCT T28 None (for isolation only) MEASUREMENT UNCERTAINTIES: Measurement uncertainties at a 95% confidence level are: AC voltage: ±0.7% AC power: ±1.2%

EMC Technologies Report No.T160402_S Page 4 of 6 TEST RESULTS OF CLAUSE 1.6.2 OF AS/NZS 60950.1:2015 1. Variable Message Sign Mono Single Line 15Ch, VMS Code: VMS-M-1-15: Test Mode Power Voltage Current Frequency Power Factor (W) (V) (A) (Hz) 1 32.5 239.9 0.199 50 0.678 2 79.2 240.0 0.383 50 0.862 Note: Test mode 1: Screen is off Idle Mode Test mode 2: A warning message is displayed repeatedly Active Mode Test conditions: In active mode, brightness setting was manually set at the maximum. The sign was scrolling horizontally displaying a line showing, Emergency Warning. A major incident has occurred in the city. Please move to the nearest Safety Site. 2. Wireless Announcement Unit, Unit Code: COMRW01 Test Mode Power Voltage Current Frequency Power Factor (W) (V) (A) (Hz) 1 28.7 240.1 0.206 50 0.585 2 28.5 240.0 0.204 50 0.582 3 35.6 240.0 0.248 50 0.596 4 43.4 240.3 0.300 50 0.602 5 62.6 240.0 0.411 50 0.631 Note: Test mode 1: No sound nor message is emitted Idle Mode Test mode 2: A warning message is spoken out repeatedly Active Mode in volume 1000 Test mode 3: A warning message is spoken out repeatedly Active Mode in volume 5000 Test mode 4: A warning message is spoken out repeatedly Active Mode in volume 13106 (the max.) Test mode 5: Siren sound, with Library key 70160, is emitted Active Mode in volume 13106 (the max.) Test conditions: In Test mode 2, 3 & 4, a message with Library key 20010 selected, was spoken by the loudspeakers saying, This is the CBD Emergency Warning System. A major incident has occurred in the city. Please move to the nearest Safety Site where more information will be provided as soon as possible.

EMC Technologies Report No.T160402_S APPENDIX I: IDENTIFICATION PHOTOGRAPHS Variable Message Sign Mono Single Line 15Ch, VMS Code: VMS-M-1-15 in Idle mode Variable Message Sign Mono Single Line 15Ch, VMS Code: VMS-M-1-15 in Active mode Page 5 of 6

EMC Technologies Report No.T160402_S Page 6 of 6 APPENDIX I: IDENTIFICATION PHOTOGRAPHS (continued) Wireless Announcement Unit, Unit Code: COMRW01