Instruction Manual ID-442 Infrared Detector 442-1A Temperature Controller Preamplifier

Similar documents
Model ID-441-C InGaAs Near Infrared Detector with Preamplifier and Thermoelectric Cooler Operating Instructions

XPIN -XT X-ray Detector Operation Manual

Indium Gallium Arsenide Detectors

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications

Photovoltaic Mercury Cadmium Telluride Detectors

CM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications

MicroSL Silicon Photomultiplier Detectors

The J22 and J23 series are high performance InGaAs detectors operating over the spectral range

DHM5150 Human Motion Sensor Module User Manual

Spectrum Detector, Inc.

Cooled Butterfly 980nm Pump Laser Module

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

IR detection module VPAC-1000F user's guide

APPLICATION NOTE. 1. Introduction Application Considerations

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Pyroelectric Infrared Sensor PIR

Preamplifier Power Supply PPS-02 user's guide

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

Model 3300 Technical Support and Installation Manual

Temperature dependent Components within the Pyroelectric Detector

DSP EC Pro. Advanced, Digital Gamma-Ray Spectrometer for HPGe Detector Systems

Product Specification

Model 5306 FAST. FOCUSED. CONTROLLED. Infrared Heaters For Controlled Concentrated Heating. Infrared Heat. Instantaneous Results.

Description. Optex Incorporated

SECTION 1: STARTING 1.1 UNPACKING AND INSPECTION

Sensor : IRA-S210ST01 Lens : IML-0685/0688 Pyro Electric Infrared Sensor Fresnel Lens Features Applications Excellent S/N Intrusion Detectors

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

DAWN Electronics, Inc.

Technical Data Sheet 5mm Infrared LED, T-1

Optical Sensor (2A) Optical Sensor Type Optical Sensor Characteristics. Young Won Lim 9/12/09

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

818 Series Low-Power Detectors

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

S/601 Controller Installation Manual

OPERATOR S MANUAL. Infinity Series Ceramic CO2 Laser: Models 15XXSB

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

IR detectors user's guide

ORTEC DSPEC LF. High-Performance Digital Signal Processor for Gamma Spectroscopy. ... in a compact package at an economical price.

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

OPERATION MANUAL MODEL & ACCELEROMETER

Exercise 1: IR Transmission and Reception

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

HGM300/RDM800 PREVENTATIVE MAINTENANCE AND TECHNICAL SUPPORT. SECTION 1 HGM300 CPU reset, RDM800 CPU reset, WARM UP notes and HGM300 Self Test

818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

Advanced Test Equipment Rentals ATEC (2832) LS-1310/1550 Laser Source. Service Information Sheet.

PONA Rack Mounted Erbium Doped Fiber Amplifier. User s Manual r001 August 30, W. Chestnut St Alhambra, CA 91803

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

EVERLIGHT ELECTRONICS CO.,LTD.

Homework 5: Theory of Operation and Hardware Design Narrative

OVEN INDUSTRIES, INC.

Measurement of Light. Photosensors

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

Electro Optical Components, Inc Skylane Boulevard, Santa Rosa, CA Toll Free: 855-EOC

OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

Tempest Hot Air Drying System. Installation Instructions. Ryobi X /98 Rev-C

SEC 2000 Millenium Infrared Gas Detector

SIL 2. Ultima X Series Gas Monitors CERTIFIED

GAMMA RAY DETECTION PROBE MODEL SO16

NIDS Dust sensor ED-N-DS-1408

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

TECHNICAL DATA OBSOLETE

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

HGM1750 Automatic Generator Module OPERATING MANUAL Smartgen Electronics

Building Name: Our Lady of Sorrows Date: July 10, 2013

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

5000 INSTALLATION GUIDE

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Air Resource Specialists, Inc.

Reflective Optical Beam Smoke Detector User Guide

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

The right fit for your high-output applications

TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY

Lamp Supply (Recommended)

Danfoss gas detection units

56W Vapor Proof LED Fixture V Dimmable - DALI Network lms - IP67 - Outdoor Applications

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

D-Tect 2 GJD300 Quad PIR Movement Detector

Model DRD-AS Conventional Infrared Flame Detector User Manual Ver. 1.0

PONA 3000 Series High Power EDFA User s Guide

Technical Data Sheet 1.6mm Side Looking Phototransistor

LCP-6144A4EDRx. 10GBASE-SR SFP+ Optical Transceiver FEATURES. Description. Applications. RoHS compliant. Compliant to SFP+ Electrical MSA SFF-8431

Thermopile Sensor TPS 230 / 3365

Motogard. Over Temperature Protection System. Installation Instructions

FUSION ALARMS TROUBLESHOOTING GUIDE CURRENT LIMIT VOLTAGE LIMIT

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

Event Detection System (EDS)

Increased safety and reducing energy consumption with the motion control RPI 01

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

OPTICAL AMPLIFIERS SELECTION GUIDE

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

Cool IR. Model C104 - Cooling System. Instruction Manual

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

Technical specifications of FT-IR Spectrometer

Transcription:

530 Main Street, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.acton-research.com Instruction Manual ID-442 Infrared Detector 442-1A Temperature Controller 442-2 Preamplifier Ver.2.0

Index: I. General Description II. III. Specifications Operation IV. Appendix A. PbS detector response characteristics B. Typical Resistance Values for a 1K Thermistor C. Connector pin descriptions

I. General Descriptions: The Acton Research Corporation ID-442 is an infrared detector assembly for the wavelength range of 1.1 to 2.9 microns. It comes complete with housing and mounting for the SpectraPro monochromators and includes a fixed bias resistor. It also includes a single stage thermoelectric cooler capable of providing a stable operating temperature to 20 degrees centigrade when used with a temperature controller such as the Acton Research Corporation 442-1A. A thermistor is provided to monitor the detector temperature and for controlling the detector cooling. The 442-1A is the optional temperature controller for the ID-441IR detector. It provides the controlled power for the thermoelectric cooler in the detector and allows setting the detector operating temperature by adjusting the thermistor resistance set point. Temperature stability is better than 0.1 degree centigrade. Both heating and cooling is provided. The 442-2 is the optional preamplifier for the ID-442 IR detector. The AC preamplifier provides a fixed gain of 100 for the detector output. It is contained in the same enclosure as the detector and signal leads are kept short to minimize noise pickup. When ordered with the 442-1 Temperature Controller, the Amplifier and Bias Power Supplies air contained in the 442-1. Otherwise, the power supplies are provided in a separate module. II. Specifications Model ID442: IR Detector Type: PbS Active Area: 5 x 5 mm Wavelength Range: 1.1 to 2.9 microns D* (Peak, 750,1): 1 x 10 11 (see curve in appendix) Max. current for thermoelectric cooler: 1.8 amps @ 0.8 volts Model 442-1A: Temperature Controller Temperature Stability: Better than 0.1 degree centigrade Provides up to 2.5 Amps of current for the thermoelectric cooler (When used with ID-442 Detector, set Current Limit to 1.8 amps) Model 442-2: Preamplifier Gain: Bandwidth: Noise: Output voltage (max): 100 (fixed) 70 Hz to 20 KHz 870 nv/hz 20 V pk pk

III. Operation Mount the ID-442 IR detector assembly to the exit slit assembly of the SpectraPro monochromator with the four cap screws provided and with the connectors on the ID- 442 toward the front of the monochromator. Connect the ID 442 IR detector assembly and optional 442-1A temperature controller as shown in Figure 1 below. The optional ID-442-2 preamplifier is factory installed inside the ID-442 detector assembly when purchased. J2 ID-442-Infrared Detector 442-2 Optional Preamplifier 442-1A Optional Temperature Controller Or Power Supply Module J1 Signal To Lock-In Amplifier The detector bias and preamplifier draw less than 10 ma of power supply and current and the power supply may remain connected to the detector with no effect on the life of the detector of preamplifier. The detector and preamplifier are meant to be operated with a chopped or alternating signal. The preamplifier output is typically connected to a lock-in amplifier. If using the 442-1A temperature controller, set the TEC CURRENT MAX SSET to 1.8 amps, the TEC TEMPERATURE SET to 7.52. This value of thermistor resistance corresponds to -20 0 C for this particular unit. If using a temperature controller other than the Acton Research 442-1A, be certain not to exceed the current and voltage ratings of the thermoelectric cooler (1.8 amps @ 0.8 volts).

IV. Appendix B: Typical Resistance Values for 1K Thermistor Temp ( 0 C) Thermistor K Temp ( 0 C) Thermistor K 0 2.558 0 2.559-1 2.666 1 2.456-2 2.779 2 2.358-3 2.897 3 2.264-4 3.021 4 2.175-5 3.151 5 2.039-6 3.288 6 2.008-7 3.431 7 1.930-8 3.581 8 1.856-9 3.739 9 1.784-10 3.905 10 1.716-11 4.079 11 1.651-12 4.261 12 1.589-13 4.453 13 1.530-14 1.654 14 1.473-15 4.866 15 1.419-16 5.088 16 1.366-17 5.322 17 1.317-18 5.567 18 1.269-19 5.826 19 1.223-20 6.097 20 1.180-21 6.383 21 1.138-22 6.683 22 1.098-23 6.999 23 1.059-24 7.332 24 1.022-25 7.681 25 0.987-26 8.049 26 0.953-27 8.437 27 0.920-28 8.845 28 0.889-29 9.275 29 0.859-30 9.727 30 0.831-31 10.204 31 0.803-32 10.705 32 0.776-33 11.235 33 0.751-34 11.792 34 0.726-35 12.379 35 0.703-36 12.998 36 0.680-37 13.651 37 0.658-38 14.339 38 0.637-39 15.065 39 0.617-40 15.830 40 0.598

IV. Appendix C: Connector Pin Descriptions: J1: Signal (BNC Connector) J2: Power / Thermoelectric Cooler 1 thermoelectric cooler + 2 thermoelectric cooler 3 thermistor 4 thermistor 5 open 6 open 7 +15volts DC 25mA 8 15 volts DC 25mA 9 ground