Photovoltaic Mercury Cadmium Telluride Detectors
|
|
- Osborn Lucas
- 5 years ago
- Views:
Transcription
1 Photovoltaic Mercury Cadmium Telluride s Teledyne Judson Technologies LLC Commerce Drive Montgomeryville, PA 89 USA Tel: -8-9 Fax: --7 Visit us on the web. ISO 9 Certified /
2 J9 PV MCT Operating Notes (. to. µm) General.E+.E+ -9C D* (Jones) J9 series detectors are high-quality HgCdTe (MCT) photodiodes for use in the nm to.µm spectral range. The equivalent circuit is a photon-generated current source Iph with parallel capacitance CD, shunt resistance RD, and series resistance RS. (Figure ) Figure ical D* vs Wavelength for room temperature and TE-, PV MCT,.8µm cutoff, mm, 8 FOV; FOV at -9C Figure Photodiode Equivalent Circuit -8C.E+ -C -C -C.E+ C.E Wavelength (um) Responsivity Cooling an MCT photodiode increases its shunt resistance which results in reduced noise and improved detectivity. Figures and show the relationship between detector temperature and detectivity (D*) as a function of wavelength. The D* plots in Figure are for a detector with an active size of mm, % cutoff wavelength at µm and operating from -C to -9C. The detectors are mounted on thermoelectric coolers (TEC) where one-stage (TE) is used for -C operation and subsequent stages (TE, TE and TE) are used to achieve lower temperatures. Similarly, Figure shows a series of plots for D* vs. wavelength for a detector with an active size of mm, % cutoff wavelength at.8µm and operating from room temperature (+C) to -9C. The field of view (FOV) is 8 except at -9C where the FOV is. Figure ical Spectral Response, PV MCT, µm cutoff, mm, TE-, 8 FOV..7. Responsivity (A/W) Temperature Effects Figures and show a typical spectral response for mm size, µm and.8µm cutoff, respectively. Please refer to Tables, and for further detector specifications for.8µm, µm and.µm wavelength cutoffs, respectively Wavelength Figure ical D* vs Wavelength for TE-, PV MCT, µm cutoff, mm, 8 FOV, -9C Figure ical Spectral Response, PV MCT,.8µm cutoff, mm, 8 FOV.E+.. Responsivity (A/W) D* (Jones) -9C -8C.E+ -C.9. -C. -C.E+9 Wavelength..... Wavelength (um) /
3 Thermoelectric Cooler Operation Advantages of Photovoltaic MCT Teledyne Judson offers a variety of convenient packages for room temperature and thermoelectrically (TE) cooled operation. ical power requirements for the TE, TE and TE coolers are shown in Figures 8, 9 and on page. The built in thermistor can be used to monitor or control the temperature. Figure shows typical thermistor resistance vs. temperature values. Sensitivity and cutoff wavelength are functions of temperature. temperature should be optimized for a particular application. Unlike the MCT photoconductors commonly used in the 7nm to.µm region, MCT photodiodes operate in the photovoltaic mode and can operate at zero bias. J9 detectors are a better choice for DC and low-frequency applications as they exhibit low /F noise characteristics as compared to PbS, PbSe and HgCdTe photoconductors. J9 detectors also offer superior pulse response for applications in monitoring and detecting high-speed pulsed lasers. They do not require a chopper and exhibit better linearity than photoconductive detectors. Figure ical Thermistor Curve Accessories Thermistor Resistance (K ) A thermoelectrically cooled detector requires a heat sink to dissipate the heat generated by the cooler, an amplifier to amplify the detector signal to a usable level and a temperature controller to hold the detector at a constant temperature. Teledyne Judson TE cooler accessories are designed to provide solutions for our customers. The CMAMP series is designed for customers that would like a fully integrated detector module. It includes heatsinking, detector signal amplification and temperature control. We also offer heat sink assemblies without preamps or temperature controllers. Please ask customer service for Product Bulletin PB for more information. Operating Circuit The recommended operating circuit for most applications is an operational amplifier in a negative-feedback transimpedance configuration (Figure 7) with up to.v reverse bias put across the detector. This reverse bias will increase the effective shunt impedance of the detector but will also increase the detector /F noise. Figure 7 ical Operating Circuit RF < V IDARK IS - Cooler / Preamplifier Recommendations Shunt Impedance Recommended Cooler Module Part to K CMAMP-TO-PA-LZ CMAMP-CN-PA-LZ 9 9 > K CMAMP-TO-PA-HZ CMAMP-CN-PA-HZ CMAMP assembly includes heat sink, temperature controller and transimpedance amplifier for the J9TE packages. Vo = IS RF + Isc Vos /
4 Table..8µm Cutoff Room Temperature and Thermoelectrically Cooled PV MCT, One Through Four Stages (TE-) Shunt impedence Active Size Operating % Cutoff (Ohm) Diameter Temp. Wavelength Wavelength Responsivity Part (A/W) (mm) ( C) Model J9:.8-8C-RU J9:.8-8C-RM J9TE:.8-C-RU J9TE:.8-C-RM J9TE:.8-C-RU J9TE:.8-C-RM J9TE:.8-C-RU J9TE:.8-C-RM J9TE:.8-CN-RU J9TE:.8-CN-RM J9TE:.8-VN-RU J9TE:.8-VN-RM TBA TBA E+ 7.E+.E+.E+ 7.E+ 7.E+.E+.E+.E+7.E+.E+7.E+.E+.E+.E+.E+.E+.E+ 8.E+ 8.E+.E+7.E+.E+7.E+ Dark -.V (A) Max.E-.E-.E-7.E-.E-8.E-7.E-9.E-8.E-9.E-8.E-9.E-8.E-.E-.E-.E-.E-7.E-.E-8.E-7.E-8.E-7.E-8.E-7 D* KHz.E+.E+ 7.7E+ 9.7E+.E+.7E+.7E+.9E+ 7.E+ 9.E+ 8.E+.E+.8E+.E+.E+.E+.9E+.7E+.9E+ 7.E+ 8.E+.E+ 8.E+.E+ All specs are for detector operation at V bias and 8 FOV unless otherwise specified. Maximum reverse bias voltage for all detectors is.v. Table..µm Cutoff Thermoelectrically Cooled PV MCT, One Through Four Stages (TE-) Model J9TE:-C-RU J9TE:-C-RM J9TE:-C-RU J9TE:-C-RM J9TE:-C-RU J9TE:-C-RM J9TE:-CN-RU J9TE:-CN-RM * J9TE:-VN-RU * J9TE:-VN-RM Shunt impedence Active Size Operating % Cutoff (Ohm) Diameter Temp. Wavelength Wavelength Responsivity Part.. (A/W) (mm) ( C) E+.E+.E+.E+.E+.E+.E+.E+.E+.E+.E+.E+.E+.E+.E+.E+ 7.E+ 7.E+.E+.E+ Dark -.V (A) Max.E-.E-.E-.E-.E-.E-.E-.E-.E-.E-.E-.E- 8.E- 8.E-.E-.E-.E-.E- 8.E- 8.E- D* KHz.E+9.E+9 7.E+9 7.E+9.E+.7E+.7E+.E+.8E+.8E+.E+9.7E+9.E+.E+.E+.E+.8E+.E+.E+.8E+ All specs are for detector operation at V bias and 8 FOV unless otherwise specified. * FOV. Maximum reverse bias voltage for all detectors is.v. Higher responsivity may be achieved at reverse bias. Table..µm Cutoff Thermoelectrically Cooled PV MCT, One Through Four Stages (TE-) Model Active Size Operating % Cutoff Diameter Temp. Wavelength Wavelength Responsivity Part.. (A/W) (mm) ( C) J9TE:.-C-RU J9TE:.-C-RM J9TE:.-C-RU 8 J9TE:.-C-RM 9 J9TE:.-C-RU J9TE:.-C-RM J9TE:.-CN-RU J9TE:.-CN-RM * J9TE:.-VN-RU * J9TE:.-VN-RM 9 All specs are for detector operation at Maximum reverse bias voltage for all Shunt impedence (Ohm) E+.E E+.E E+.E E+.E E+.E E+.E E+.E E+.E E+.E E+.E+ V bias and 8 FOV unless otherwise specified. * FOV. detectors is.v. Higher responsivity may be achieved at reverse bias. Dark -.V (A) Max.E-.E-.E-.E-.E-.E-.E-.E-.E-.E-.E-.E-.E-.E-.8E-.8E-.E-.E-.E-.E- D* KHz.E+9.8E+9.9E+9.9E+9.E+.E+.E+.E+.9E+.7E+.E+9.E+9 8.E+9 8.E+9.7E+.9E+.E+.E+.E+.E+ /
5 C/D Package CN Package. Thk AR Coated Sapphire Window. MAX. Top, Sealant. DIA.. Dia.. Clear Aperture Outer, Top Cap C: AR Coated Sapphire Window D: Sapphire Window. SQ.7 DIA. REF. Sealant.7 TYP Top,.. ±. MAX.8 ±..9 ± REF. 7 Side View Pin No. Designation Sleeve Color Thermistor Cathode (-) White Yellow Anode (+) Green Cooler (-) Black Cooler (+) Red N/C Clear 7 N/C Clear 8 Thermistor Yellow 7S Package 8C Package Figure 8 Temperature vs TE Cooler Current Figure 9 Temperature vs TE Cooler Current Figure Temperature vs TE Cooler Current /
6 In addition to our Photovoltaic MCT product line, Teledyne Judson Technologies offers a wide range of high performance standard, custom and space qualified detector products and accessories. Germanium detectors and arrays Indium Arsenide detectors and arrays Indium Antimonide detectors and arrays Mercury Cadmium Telluride detectors and arrays Lead Selenide detectors and arrays Lead Sulfide detectors and arrays Dewars, backfill and vacuum packages Thermoelectric, Joule Thomson and closed cycle linear and rotary coolers Preamplifiers Temperature controllers and readout electronics Please contact us for more information on these products at -8-9 or on the web at Commerce Drive Montgomeryville, PA 89 USA Tel: -8-9, Fax: November, /
Indium Gallium Arsenide Detectors
Indium Gallium Arsenide Detectors Teledyne Judson Technologies LLC 221 Commerce Drive Montgomeryville, PA 18936 USA Tel: 215-368-6900 Fax: 215-362-6107 ISO 9001 Certified Visit us on the web. www.teledynejudson.com
More informationThe J22 and J23 series are high performance InGaAs detectors operating over the spectral range
PB 4206 September 2003 CAUTION! General To avoid heat damage to the detector, use a heat sink (such as a pair of tweezers) on the pin when soldering TO-style packages. Avoid touching the package window.
More informationModel ID-441-C InGaAs Near Infrared Detector with Preamplifier and Thermoelectric Cooler Operating Instructions
15 Discovery Way, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.piacton.com Model ID-441-C InGaAs Near Infrared Detector with Preamplifier and Thermoelectric Cooler Operating Instructions
More informationInstruction Manual ID-442 Infrared Detector 442-1A Temperature Controller Preamplifier
530 Main Street, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.acton-research.com Instruction Manual ID-442 Infrared Detector 442-1A Temperature Controller 442-2 Preamplifier Ver.2.0
More informationFTIR-OEM IR source, interferometer & detector modules for modular and OEM applications
FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications The ARCoptix FTIR OEM modules have been developed for system integrators and people looking for a custom FTIR measurement
More information818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)
132 P hotonics LASER DIODE TESTING FIBER OPTIC TEST Key Features Power levels from pw to 2W Wavelengths from 190 1800 nm Proprietary detector optics Patented, matched OD3 attenuator NIST/NPL-traceable
More informationRoom Temperature MWIR FPAs: Return of the Lead Salts?
Approved for public release; distribution is unlimited. Room Temperature MWIR FPAs: Return of the Lead Salts? Steven Jost, John Kuppenheimer and Greg Dudoff Sanders, A Lockheed Martin Company, Nashua,
More informationCM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications
Cooled 980nm Pump Laser Module Features High output power, >1.0W kink free Fiber Bragg grating stabilization for wavelength locking over the entire operating conditions Hermetically sealed 10pin mini-butterfly
More informationCatalogue Photonic Solutions Ltd
Catalogue Photonic Solutions Ltd Unit., Quantum Court, Research Avenue South, HU Research Park, Edinburgh, EH AP, UK, Tel: + (0) Email sales@photonicsolutions.co.uk eb www.photonicsolutions.co.uk TABLE
More information818 Series Low-Power Detectors
1090 818 Series Low-Power Detectors Newport uses the highest quality semiconductor detector materials available in our 818 Series Low-Power Detectors. In addition, each detector arrives with a complete
More informationIR detectors user's guide
IR detectors user's guide 129/133 Poznanska St., 05-850 Ozarow Mazowiecki, Poland; tel. +48 22 733 54 20; fax +48 22 733 54 26; e-mail: info@vigo.com.pl 1 Please note: the information contained in this
More informationTECHNICAL INFORMATION SD-12 Characteristics and use of infrared detectors
TECHNICAL INFORMATION SD-12 Characteristics and use of infrared detectors Introduction Infrared radiation consists of electromagnetic waves in the wavelength region from 0.75 µm to 1000 µm, lying between
More informationLow-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics
818 Series TUTORIAL SPECTRUM ANALYZER HIGH-POWER DETECTORS INTEGRATING SPHERES LOW-POWER DETECTORS POWER & ENERGY METERS Key Features Power levels from pw to 2W Wavelengths from 190 nm to 1800 nm Proprietary
More informationOptical Sensor (2A) Optical Sensor Type Optical Sensor Characteristics. Young Won Lim 9/12/09
Optical Sensor (2A) Optical Sensor Type Optical Sensor Characteristics Copyright (c) 2009 Young W. Lim. Permission is granted to copy, distribute and/or modify this document under the terms of the GNU
More informationMicroSL Silicon Photomultiplier Detectors
MicroSL Series User Manual SensL MicroSL detectors are based on the silicon photomultiplier (SPM) concept and form a range of high gain, single-photon sensitive, visible light sensors. The MicroSL family
More informationAPPLICATION NOTE. 1. Introduction Application Considerations
GE Thermometrics Technologies APPLICATION NOTE C o n t e n t s 1. Introduction -------------------------------------------------- 1 2. Application Considerations ------------------------------ 2 3. Typical
More informationXPIN -XT X-ray Detector Operation Manual
Detectors XPIN -XT X-ray Detector XPIN-XT-AB (Angle bracket sold separately) XPIN-XT-HS (Heat sink sold separately) DET-MAN-MED00014, Rev C, Page 1 Contents XPIN-XT X-ray Detector... 3 Initial Inspection...
More informationCooled Butterfly 980nm Pump Laser Module
Cooled Butterfly 980nm Pump Laser Module Features: High output power, up to 600mW kink free Polarization maintaining fiber pigtail Fiber Bragg grating stabilization for wavelength locking over the entire
More informationTemperature dependent Components within the Pyroelectric Detector
1 Introduction This application note is offered to provide some insight into how temperature affects the various components of a typical pyroelectric detector and how the effects of ambient temperature
More informationINFRARED COMPONENTS.
INFRARED COMPONENTS www.lasercomponents.com Nearly every week I got new or improved lasers on my desk for testing. Improved or even new detectors are very rare. Peter Kaspersen Infrared Tradition Dear
More informationSpectrum Detector, Inc.
Spectrum Detector, Inc. Pyroelectric detectors design and manufacture LiTaO3/LiNO3 crystal processing thin film metallization UV photo lithorgraphy hybrid assembly and packaging black absorbing coatings
More informationThe new generation Teledyne NIR detectors for the SNAP/JDEM mission spectrograph.
The new generation Teledyne NIR detectors for the SNAP/JDEM mission spectrograph. 1 Outline The SNAP/JDEM mission The SNAP/JDEM spectrograph and the IR spectrograph detector requirements R&D program for
More informationThe Art and Science of Being Cool
2016 Princeton Instruments, Inc. All rights reserved. The Art and Science of Being Cool An Introduction to the Newest Generation of Scientific Camera Cooling Technologies Overview Many low-light imaging
More informationDescription. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1
Description The DFB-1XXX-BF-XX-CW-Fx-Hx-N127 series of Multi-Quantum Well (MQW) Distributed Feedback (DFB) lasers have been designed specifically to satisfy the requirements of the sensor application.
More informationCustomization of Optoelectronic Detectors Part Two in a Six-Part Series
Customization of Optoelectronic Detectors Part Two in a Six-Part Series Utilizing our 30 years of experience in optoelectronics, Marktech s customization process focuses on customer needs and applications.
More informationdewar or an electrically powered cooler. The sensitive detector surfaces are thus protected from moisture and condensable contaminants.
Germanium Detectors The Company Canberra Industries is the world's largest manufacturer of nuclear radiation detection and analysis systems. In order to better serve our customers worldwide, Canberra operates
More informationG155PU001S. Pigtailed 14-PIN DIL Laser Diode with TEC. FLMS Min. Typ. Max.
G155PU001S TECHNICAL DATA Pigtailed 14-PIN DIL Laser Diode with TEC Features 1 mw 1550 nm MQW Laser Diode Module with cooler 14pin DIL package with single mode fiber output Applications Optical Communication
More informationNew IR-detectors pig-tailed with IR-fibers
New IR-detectors pig-tailed with IR-fibers Viatcheslav G. Artiouchenko a)*, Galina V. Chekanova b), Ivan Yu. Lartsev b), Vladimir A. Lobachev c), Mikhail S. Nikitine b) a) A.R.T. Photonics GmbH, Schwarzschildstrasse
More informationUnderstanding total measurement uncertainty in power meters and detectors
Understanding total measurement uncertainty in power meters and detectors Jay Jeong, MKS Instruments. Inc. INTRODUCTION It is important that users of calibrated power meters and detectors understand and
More informationIR detection module VPAC-1000F user's guide
IR detection module VPAC-1000F user's guide 129/133 Poznanska St., 05-850 Ozarow Mazowiecki, Poland; tel. +48 22 733 54 20; fax +48 22 733 54 26; e-mail: info@vigo.com.pl 1 Table of Contents 1. Warranty...
More informationMeasurement of Light. Photosensors
Measurement of Light Photosensors Detection of light is a basic need for everything from devices to plants and animals. In the case of animals, light detection systems are very highly specialized, and
More informationSelection guide - September Covering a broad spectral range in the infrared region HAMAMATSU PHOTONICS K.K.
Selection guide - September 217 Infrared Detectors Covering a broad spectral range in the infrared region HAMAMATSU PHOTONICS K.K. Infrared detectors Infrared detectors are widely used in diverse field
More informationTechnical Data Sheet 5mm Infrared LED, T-1
Technical Data Sheet 5mm Infrared LED, T-1 Features High reliability 2.54mm lead spacing Low forward voltage Good spectral matching to Si photodetector Pb free The product itself will remain within RoHS
More informationOTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL
OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL Phone: (209) 586-022 (800) 545-022 Fax: (209) 586-026 E-Mail: salessupport@olsontech.com www.olsontech.com OTEB-CO-B (No SNMP) Rev. X7 /7/200 SAFETY WARNINGS
More informationPaper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 1
Page 1 Paper 3-B-01 / Cured in Place Pipeliners A New UV Sensor Method for Sewer Renovation Michael Roeling, Export Manager BKP Berolina Polyester GmbH & Co. KG, Velten, Germany Page 2 UV Curing of CIPP
More informationElectro Optical Components, Inc Skylane Boulevard, Santa Rosa, CA Toll Free: 855-EOC
Electro Optical Components, Inc. 546 Skylane Boulevard, Santa Rosa, CA 9543 Toll Free: 855-EOC-63 www.eoc-inc.com info@eoc-inc.com PROFILE BEIJING REALLIGHT TECHNOLOGY CO., LTD Address:3rd Floor, #1 Building,
More informationHOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control
Wide Gap Transmissive Sensor HOA1888 Series FEATURES Choice of phototransistor or photodarlington output Visible ambient light and dust protective filter 12 mm (0.47 in.) slot width Snap-in housing The
More informationDate: Wednesday, January 31, 2018 Time: 8:30 am 5:00 pm Location: Moscone West (Room 2018, Level 2)
Optics Lasers Detectors FREE WORKshops Date: Wednesday, January 31, 2018 Time: 8:30 am 5:00 pm Location: Moscone West (Room 2018, Level 2) The team from LASER COMPONENTS is holding a free one-day workshop
More informationOn-chip optical detectors in Standard CMOS SOI
On-chip optical detectors in Standard CMOS SOI Dr. Matthias Fertig Project Manager for New Product Development Volvo AG Advisory Engineer Microprocessor Development IBM Research and Development Outline
More informationModular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights
Product Overview LED SOLUTIONS COBRA Slim Line lights Intensity: Now up to 2900 klux Design: Slim and compact Field adjustable: focusing distance and diffusers Chip-On-Board: Extreme brightness and high
More informationHOA0880-T51. Representative photograph, actual product appearance may vary.
Representative photograph, actual product appearance may vary. HOA0880-T51 HOA Series Infrared Transmissive Sensor, Transistor Output, Two- Mounting Tabs, Plastic package Due to regional agency approval
More informationErbium-Doped Fiber Amplifier (EDFA) - MW Series
Nanovation s MW series of EDFA products is designed for applications in advanced dense wave division multiplexing (DWDM) systems where high performance and reliability are critical. They are available
More informationDated 15-Dec-2000; J. Schilz, subject to change
product data infrared sources preliminary! Infrared source 5 V, 115 ma, 3.17 mm diameter Features: - Incandescent infrared source up to 4.4 µm, - high reliability, - stable output, - short time constant.
More informationLasers Technical Seminar at Bruno Events Center on March 27 th, Next generation of SPADs - Single Photon Avalanche Detectors
Lasers Technical Seminar at Bruno Events Center on March 27 th, 2012 Next generation of SPADs - Single Photon Avalanche Detectors LASER COMPONENTS, 2012 Lasers Technical Seminar, Tel Aviv March 27 th,
More informationTechnical Data Sheet 1.5mm Side Face Infrared LED
Technical Data Sheet 1.5mm Side Face Infrared LED Features High reliability High radiant intensity Peak wavelength λp=940nm 2.54mm Lead spacing Low forward voltage Pb free This product itself will remain
More informationLECTURE 11. Dr. Teresa D. Golden University of North Texas Department of Chemistry
LECTURE 11 Dr. Teresa D. Golden University of North Texas Department of Chemistry C. Detectors Properties of Detectors -quantum counting efficiency -linearity -energy proportionality -resolution C. Detectors
More informationNIDS Dust sensor ED-N-DS-1408
SPECIFICATION (Tentative) Product Name: Dust Sensor(High Sensitivity) Model No. : SM-PWM-01A-HS SMART dust sensor for air purifier SM-PWM-01A-HS Description SM-PWM-01A-HS is a dust sensor that detects
More informationNX7363JB-BC. Data Sheet R08DS0009EJ0200 Rev.2.00 LASER DIODE. Sep 19, 2010 DESCRIPTION FEATURES
A Business Partner of Renesas Electronics Corporation. NX7363JB-BC LASER DIODE InGaAsP MQW DC-PBH PULSED LASER DIODE MODULE 1 310 nm OTDR APPLICATION Data Sheet DESCRIPTION The NX7363JB-BC is a 1 310 nm
More informationmach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes
mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes Measure every pulse at pps! Our new mach 5 Digital Joulemeter is designed to measure laser pulse energy up to 130,000 pps with
More informationThe FEL Facility Optical Diagnostics and FEL Characterization
The FEL Facility Optical Diagnostics and FEL Characterization M. Shinn, C. Behre, S. Benson, J. Coleman, R. Evans, A. Grippo, J. Gubeli, D. Hardy, K. Jordan, G. Neil, S. Zhang G. Williams Jefferson Lab
More informationProduct Specification
Product Specification M7300CD Variable Gain EDFA, 17 dbm OP, 15-30 db Gain PN: FOA-M7300CD-EVG1C-AA002 Document No.: 1213704 Revision: A00 Date: 01-Apr-14 Customer: General Product Features Variable Gain
More informationModels S310 & S310D Laser Power and Energy Meters Setup and Operating Procedures
Models S310 & S310D Laser Power and Energy Meters Setup and Operating Procedures Serial Number P/N 10190M Thank you for choosing a Scientech laser power and energy meter. Scientech, an ISO 9001 registered
More informationFABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT
FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT Sivakumar.N a*, Agathiyan.V, Dhanush.S, Gokulnath.V, Jagadhesan.R b, c, d, e UG Scholar, Department of Mechanical Engineering, Gnanamani College
More informationCOMPACTNESS 34.1 PERFORMANCE ANTICIPATION
BEAM DIAGNOSTICS SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER SOLUTIONS POWER DETECTORS ENERGY DETECTORS MONITORS PRESENTATION OVERVIEW OF THE DIFFERENT MODELS The Gentec-EO
More informationHigh Throughput Large Area Silicon Drift Detectors
KETEK GmbH High Throughput Large Area Silicon Drift Detectors J. Knobloch, T. Eggert, R. Fojt, L. Höllt, A. Pahlke, R. Stötter EPS-TIG Workshop Advanced Radiation Detectors for Industrial Use 1 Outlook
More informationarxiv:astro-ph/ v1 17 Aug 2000
Development of Gold Contacted Flip-chip Detectors with IMARAD CZT T. Narita 1, P.F. Bloser 1, J.E. Grindlay 1, J.A. Jenkins 1 1 Harvard-Smithsonian Center for Astrophysics, 6 Garden St., Cambridge, MA
More informationSOLAR CELL PRODUCTION REQUIRES EFFECTIVE METROLOGY
SOLAR CELL PRODUCTION REQUIRES EFFECTIVE METROLOGY 6/12/2010 Recent IR Thermography Developments Can Help Agenda: Infrared Cameras for Solar Cell Inspection Survey of current solar cell test methods New
More informationDust sensor SM-PWM-01A SPECIFICATION. Product Name: Dust Sensor Model No. : SM-PWM-01A 1 / 12
SPECIFICATION Product Name: Dust Sensor Model No. : SM-PWM-01A 1 / 12 SM-PWM-01A SMART dust sensor for home appliance Description SM-PWM-01A is a dust sensor that detects the dust particle concentration
More informationPower Meters Energy Meters
Power Meters Energy Meters based on Pyroelectric detectors Si-, Ge- and InGaAs- detectors Thermopile detectors especially for laser applications Advancing Measurements by Light www.polytec.com Product
More informationInstruction Manual. gray Housed Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:
gray Instruction Manual for gray Housed Detectors F: +41 44 633 13 68 info@ 2 / 10 gray Housed Detectors: Instruction Manual CONTENT 1. SHORT USER GUIDE... 4 2. THERMAL INTEGRATION OF THE DETECTOR... 5
More informationFiber Optics and Liquid Level Sensors Line Guide
Fiber Optics and Liquid Level Sensors Line Guide Excellence, through every fiber. Honeywell Sensing and Control (S&C) offers fiber optic sensors manufactured with SERCOS (Serial Real-time Communication
More informationCOMPACTNESS 34.1 PERFORMANCE ANTICIPATION
BEAM DIAGNOSTICS SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER SOLUTIONS POWER DETECTORS ENERGY DETECTORS MONITORS PRESENTATION PRODUCT CHARACTERISTICS Gentec-EO offers OEM customers
More informationto get there. together. Infrared Sources Swiss made
to get there. together. Infrared Sources Swiss made p. 2 www.axetris.com Overview Axetris infrared (IR) sources are micro-machined, electrically modulated thermal infrared emitters featuring true black
More informationDISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS
WITH INTERCONNECT Data Sheet 60.6 NO CONNECT. I / O LOW-V SET NO CONNECT. LED + SUPPLY TIMING RES. FEEDBACK 3 4 5 6 7 NC NC LOGIC OSC. & TIMING DRIVER 0 6 5 4 3 8 V SS GUARD DETECT. IN GUARD SENSITIVITY
More informationMULTI-FUNCTION InGaAs DETECTOR FOR SWIR IMAGING
OPTRO-214-293312 MULTI-FUNCTION InGaAs DETECTOR FOR SWIR IMAGING Lior Shkedy (1), Alina Koifman (1), Avihoo Giladi (1), Avi Tuito (2), Elad Ilan (1), Ilana Grimberg (1), Itay Hirsh (1), Leonid Bykov (1),
More informationMedipix PCBs and mechanics
PCBs and mechanics Sabine Lange, Sergej Smoljanin, David Pennicard, Matthias Bayer Detector Group DESY AGIPD Meeting 06.09.2011 Detector assembly on ceramic PCB Side view Sensor Readout chip Readout chip
More informationCCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800
SENSORS & SYSTEMS Authority in Displacement Measurement CCD-Precision high accuracy and resolution compact sensor design 5 khz frequency N ILD 1800 TRIANGULATOI PRINCIPLE OPTO NCDT Intelligent Laser-Optical
More informationOur photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.
PHOTO DETECTORS BEAM DIAGNOSTICS SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER SOLUTIONS POWER DETECTORS ENERGY DETECTORS MONITORS PRESENTATION OVERVIEW OF THE DIFFERENT MODELS
More informationMEAS EMITTER ASSEMBLY ELM-4000 SERIES
MEAS EMITTER ASSEMBLY ELM-4000 SERIES SpO2 optical sensor component Dual Drive Lead Frame Construction Pulse Oximetry Component Clear Epoxy Low oxygen level can put a strain on cell functioning including
More informationSpeed and Frequency Seite 1 von 7
Speed and Frequency Seite 1 von 7 E16 Systems for High Safety Speed ing, all with Triple Modular Redundancy. A choice of versions to meet various demands. Compliant with SIL3 / IEC 61508 and/or API 670.
More informationOur photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.
BEAM DIAGNOSTICS SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER SOLUTIONS POWER DETECTORS ENERGY DETECTORS MONITORS PRESENTATION OVERVIEW OF THE DIFFERENT MODELS Our photo detectors
More informationDescription. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications
Description The DFB-XXX-BF-10-EC-Fx-Hx-N126 laser modules are designed for fiber optic sensor applications. The narrow linewidth and the option of using polarization maintaining optical fiber made it specially
More informationInstruction Manual. gray Mounted Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:
gray Instruction Manual for gray Mounted Detectors F: +41 44 633 13 68 2 / 12 gray Mounted Detectors: Instruction Manual CONTENT 1. SHORT USER GUIDE... 4 2. THERMAL INTEGRATION OF THE DETECTOR... 5 2.1.
More informationInstruments Designed for POF & Fibre Optic Cable Testing
XL fibertools Series Instruments Designed for POF & Fibre Optic Cable Testing The XL fibertools are designed for the professional to perform installation and maintenance measurements on both Plastic &
More information2015 Amphenol Advanced Sensors. Jinton Industrial Park, Wujin, Changzhou, Jiangsu, China. Web:
AAS-920-668A Nov., 2015 2015 Amphenol Advanced Sensors Jinton Industrial Park, Wujin, Changzhou, Jiangsu, China Web: www.amphenol-sensors.com Table of Contents 1. Description...................................................................
More informationAutonomous Vehicles. Pushing the Boundaries of Sensors and Emitters Reader Issue Beacons of the Industry Annual Reader Poll
www.photonics.com September 2017 2017 Reader Issue Beacons of the Industry Annual Reader Poll Autonomous Vehicles Pushing the Boundaries of Sensors and Emitters A unmanned military drone using lidar for
More informationSurface Mount 905 nm Pulsed Semiconductor Lasers High Power Laser-Diode Family for Commercial Range Finding
DATASHEET Photon Detection Surface Mount 905 nm Pulsed Semiconductor Lasers Near field profile Key Features Multi cavity lasers concentrate emitting source size Quantum well structure High peak pulsed
More informationDefense Technical Information Center Compilation Part Notice
UNCLASSIFIED Defense Technical Information Center Compilation Part Notice ADP010827 TITLE: Characteristics of Infrared Detectors for Spece Applications DISTRIBUTION: Approved for public release, distribution
More informationLeuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001
Throughbeam photoelectric sensors Dimensioned drawing 15m 1-3 V DC A 2 LS Throughbeam photoelectric sensors with high performance reserve in infrared light Robust metal housing with glass cover, protection
More informationChemistry Instrumental Analysis Lecture 4. Chem 4631
Chemistry 4631 Instrumental Analysis Lecture 4 Atomic Spectroscopy Atomic Spectroscopy UV to IR Optical spectroscopy are based on: absorption fluorescence phosphorescence scattering emission chemiluminescence
More informationCatalog Pyroelectric & Multispectral Detectors uncooled highly stable high performance highest quality. multi color.
Catalog 203 multi color gas analysis Pyroelectric & Multispectral Detectors uncooled highly stable high performance highest quality Product Group Outlines 203 Group Channel Housing Aperture size [mm] Chip
More informationT2SL technology for Mid-IR detectors
T2SL technology for Mid-IR detectors Linda Höglund Minerva Workshop June, 30 th 1 Outline Introduction Tasks in MINERVA Starting point: MW detectors 320 256 on 30 µm pitch Technologies developed in MINERVA
More informationCharacterization of High Speed Optical Detectors for Purpose of OM4 Fibre Qualification: Selective Mode Detection
Characterization of High Speed Optical Detectors for Purpose of OM4 Fibre Qualification: Selective Mode Detection F. J. Achten 1 and D. Molin 2 1 Prysmian Group, Zwaanstraat 1, 5651CA Eindhoven, Netherlands
More informationUNCOOLED MICROBOLOMETER DETECTOR : RECENT DEVELOPMENTS AT ULIS
Thermogram 2005 1 UNCOOLED MICROBOLOMETER DETECTOR : RECENT DEVELOPMENTS AT ULIS J.L. Tissot, B. Fièque, C. Trouilleau, A. Crastes, O. Legras ULIS BP 27 38113 Veurey-Voroize, France jl.tissot@ulis-ir.com
More informationUtilizing Finite Element Analysis (FEA) for Flexible Heater Designs
Utilizing Finite Element Analysis (FEA) for Flexible Heater Designs Ryan Mohs, Process Engineer, All Flex. Flexible heaters are commonly utilized in many different heating applications. Generally, these
More informationAdvantages / Characteristics
Air to Air 50 W 30 W cooling capacity 163x104x144mm (LxBxH) 1,9 kg Air to Air 70 W 36 W cooling capacity 163x104x144mm (LxBxH) 1,9 kg Air to Air 75 W 30 W cooling capacity 130x109x163mm (LxBxH) 1,5 kg
More informationPD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.
PD100MF0MPx Surface Mount Type, Opaque Resin Photodiode Features 1. Compact and thin SMD package 2. Top view and side view mountable 3. Plastic mold with visible light cut-off black resin lens 4. Peak
More informationDescription. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications
Description The DFB-XXX-BF-10-EC-Fx-Hx-N126 laser modules are designed for fiber optic sensor applications. The narrow linewidth and the option of using polarization maintaining optical fiber made it specially
More informationHM1520LF Relative Humidity Module
SPECIFICATIONS Tubular form for through wall mounting Product free from Lead, Cr(6+), Cd and Hg Calibrated, linear voltage for easy electronic interface Typical 1 to 1.6 Volt DC output for 0 to 20% RH
More informationDesign of Classroom Intelligent Lighting System Based on SCM. Jiale Zheng1, a
6th International Conference on Machinery, Materials, Environment, Biotechnology and Computer (MMEBC 2016) Design of Classroom Intelligent Lighting System Based on SCM Jiale Zheng1, a 1 North China Electric
More informationLM-80V , h V LM-30V h V
Smart QuadSensors Beampositioning with Laserpad, FieldMaster, FieldMaster-GS and Ultima LabMaster Catalog Name Power Aperture Notes Spectral Accuracy For Single Shot Use with Sensor Number (mm) Range (±
More informationII-VI SUWTECH INC.
VERSION Add: F, Building 6, Hongcao Road, Shanghai,, China Tel: + 86 - - 68-978 Fax: + 86 - - 68-89 Email: Suwtech.Laser@ii-vi.com Website: www.ii-vi-suwtech.com II-VI SUWTECH INC. www.ii-vi-suwtech.com
More informationSMART Dust Sensor. Amphenol Advanced Sensors SM-PWM-01C. Application Note. Features
Application Note SMART Dust Sensor SM-PWM-01C SM-PWM-01C dust sensor detects dust particle concentration in air by using an optical sensing method. An infrared light emitting diode (IR LED) and a photo-sensor
More informationMiniature Thermoelectric Cooler Controller MTCC-01 user's guide
Miniature Thermoelectric Cooler Controller MTCC-01 user's guide 1 Table of Contents 1. Warranty... 3 2. MTCC-01-xxx overview... 4 2.1. MTCC-01-xxx specification... 4 2.2. TE cooled detector temperature
More informationTechnical Data Sheet 1.6mm Side Looking Phototransistor
Technical Data Sheet 1.6mm Side Looking Phototransistor Features Fast response time High sensitivity Small junction capacitance Pb free This product itself will remain within RoHS compliant version. Descriptions
More informationOPERATOR S MANUAL. Infinity Series Ceramic CO2 Laser: Models 15XXSB
92-3031 OPERATOR S MANUAL Infinity Series Ceramic CO2 Laser: Models 15XXSB www.iradionlaser.com Table of Contents Table of Contents... 2 Hazard Information... 3 Terms... 3 General Hazards... 4 Label Locations...
More informationICS Integrated Cryocooling System
ICS Integrated Cryocooling System ORTEC s most advanced Integrated Cryocooling System offers premium detector resolution and LN 2 -free operation, for excellence in performance, safety, reliability and
More information高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are
*Instruments for optical spectroscopy: Optical spectroscopic methods are based on 6 phenomena: 1) Absorption, 2) Fluorescence, 3) Phosphorescence, 4) Scattering, 5) Emission and 6) Chemiluminescence. Typical
More informationIR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance
IR4000 Point Infrared Combustible Gas Detection System The Reliable and Flexible Safety Solution That s Low Maintenance Multi-Point Gas Detection That s Fast Set-Up, Low Maintenance, Cost-Effective The
More informationTHE PLACE TO BE FOR AUVERGNE RHÔNE-ALPES COMMITTED FRENCH TECH MEMBER
THE PLACE TO BE FOR photonics TECHNOLOGIES The Moscone Center San Francisco, California, United States 27 January - February 208 AUVERGNE RHÔNE-ALPES COMMITTED FRENCH TECH MEMBER 5 6 2 7 F L O O R P L
More information