CHINOOK THE INDUSTRY S MOST COMPLETE LINE. WARM AIR GAS FURNACE DESIGNED, ENGINEERED, AND MANUFACTURED IN CANADA

Similar documents
CHINOOK WARM AIR GAS FURNACE DESIGNED, ENGINEERED AND MANUFACTURED IN CANADA INCLUDING COMPONENTS MADE IN THE USA

CHINOOK WARM AIR GAS FURNACE DESIGNED, ENGINEERED AND MANUFACTURED IN CANADA INCLUDING COMPONENTS MADE IN THE USA

G6RC Series TECHNICAL SPECIFICATIONS

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

Superior, ultra-quiet power vent water heaters

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

RHEEM 90%+ GAS FURNACES

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

RIGHT-SIZED SYSTEM SMART DUCT SYSTEM

SMART DUCT SYSTEM. Caution: Do not tamper with the unit or its controls. Call a qualified service technician.

TECHNICAL SPECIFICATIONS

FG7T (C and L Series)

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

USER S MANUAL AND INSTALLATION INSTRUCTIONS IMPORTANT

What you need to know about residential furnaces, air conditioners and heat pumps if you re NOT an HVAC professional

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

TECHNICAL SPECIFICATIONS

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Installation Instructions

Commercial Gas Water Heaters

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

COMMUNICATING TWO-STAGE VARIABLE SPEED MULTI-POSITION GAS FURNACES

GMS9/GCS9 SERIES 93% AFUE

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

TECHNICAL SPECIFICATIONS

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

Product Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

ELITE SERIES Downflow - High Efficiency Blower Motor

MULTI POSITION GAS FURNACE

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

Propane & Gas Heating

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

Multi-Position Gas Furnaces

AMVM97 (B) / ACVM97 (B)

GMH95/GCH9 MULTI-POSITION, DUAL$AVER CONVERTIBLE, MULTI-SPEED GAS FURNACE

Wt. Lbs Model Number (BTUH) Hz

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

RTHE Series R Helical Rotary Liquid Chiller Tons 60Hz

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

Rheem Prestige Series Communicating Two-Stage Variable Speed Multi-Position. Gas Furnaces

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

Multi-Position Gas Furnaces

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

Installation instructions for Plenum-mounted add-on electric heaters MODEL TU. MARCH 2011 version 7

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

Rheem Prestige Series EcoNet Enabled Modulating Upflow Gas Furnaces

Ruud Achiever Plus Series Multi-position Gas Furnaces

Cooling Capacity CFM range

GEOTHERMAL: THE SMARTER CHOICE

Ruud Ultra Series EcoNet Enabled Two-Stage Variable Speed Multi- Position Gas Furances

TSTAT0201CW Recommended (sold separately)

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

95.8. The leading name in local furnaces now has a new generation. + Performance. + Comfortable. + Economical operation. + Ease of maintenance

GMVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

MULTI POSITION GAS FURNACE

Product Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

- high efficiency - condensing gas furnace up to 10.8 eer air conditioning

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Product Data PG95XAT CONDENSING GAS FURNACE SERIES B STANDARD FEATURES

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

ComfortNet -Compatible

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

Adsorption Dryers for Compressed Air

Installation Instructions

GAS FURNACES. Visit taxcredit for complete details.

INTEGRATED HVAC & WATER HEATING

FREE JOINT MULTI. Multi-Zone Mini Split Air Conditioner. Ver quietside.com

Installation Instructions WARNING: WARNING: GAS FURNACES 95.1% AFUE. Two-Stage Condensing Furnaces With Fixed and Variable Speed Blowers

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

- high efficiency - condensing gas furnace up to 10.8 eer air conditioning

Energy Saving. Space Saving.

VICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES.

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

Product Data A {Jurisdictions where warranty benefits cannot be conditioned on registration

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Transcription:

HINOOK Ultra compact size, featuring the industry s smallest footprint Right-sized for today s more effi cient homes and new codes THE INDUSTRY S MOST OMPLETE LINE. WARM AIR GAS FURNAE DESIGNED, ENGINEERED, AND MANUFATURED IN ANADA Ideally suited to the replacement market Allows the Right-Sized System in combination with our Alizé cooling unit Stainless steel primary and secondary heat exchangers Part of our HVA in a box solution

HINOOK Benefits and differentiators Smallest footprint in the industry (height and width) Meets the existing replacement market requirements for both cooling and heating Designed for the rapidly changing new construction market which requires smaller capacity appliances due to better and tighter envelopes Zero-clearance certifi cation for new construction and renovation projects An excellent central system solution for both the multifamily and single family home markets Designed and built with input from partners across North America including : gas laboratories, utilities, builders, contractors and distributors an be installed with our Smart Duct System as well as in a traditional tional duct environment Product line features Effi ciency over 95 % (AFUE) Efficient combustion, stable at both high and low firing rates Quiet warm air and convenient heating capacities Full product line from 15,000 to 120,000 BTU/h on fi ve platforms: - Modulating (from 40 to 100%) - 2 stage PS or EM motor - Single stage PS or fi xed torque EM motor (X13) Multiposition: ready for upflow, simply modify condensate tubing for downflow and horizontal Optional propane conversion kits are available Reliable appliance that offers a safe maintenance environment Stainless steel extruded tube heat exchanger; primary (SS 409) and secondary (AL 29-4) The ID blower has a single position independent of appliance orientation (Multiposition ready) Easy access to components for maintenance No sharp edges Transparent drain trap ontrol board located in the top compartment The hinook gas furnace family can operate efficiently in a traditional duct environment or using the Smart Duct System MAXIMUM EQUIVALENT STRAIGHT VENT LENGTH FROM FURNAE TO OUTDOOR Altitude (ft) 0 to 4500 Altitude (ft) 0 to 4500 MODULATING AND 2 STAGE UNITS Unit size (BTU/h) Vent pipe diameter 2 3 15,000 300 N/A 30,000 180 N/A 45,000 70 90 60,000 70 90 75,000 70 90 105,000 15 80 120,000 10 40 1 STAGE UNIT Unit size (BTU/h) Vent pipe diameter 2 3 45,000 70 90 60,000 45 90 75,000 30 90 105,000 N/A 70 120,000 N/A 40

HINOOK A B SUPPLY OUTLET WIDTH VENT 2 19,00 9,56 AIR INTAKE 2 (RETURN OUTLET WIDTH) 33,64 15.25 13.25 11.25 1,03 RETURN OUTLET HEIGHT 1,24 Z Y X 24,00 29,18 Z Y X It s hard to beat having a homeowner come up to you thanking you for installing a furnace and air conditioner system that is so quiet they keep checking on it to see if it s working. onstant AIR RETURN Position X Y Z Furnace size 15 @ 45 000 60 @ 75 000 90 @ 120 000 temperature, high effi ciency and quieter performance are some of the benefi ts that our customers are commenting on. As I ve said before it s like swapping out your old gas guzzling tank for DIMENSIONS (inches) Furnace size A abinet width B Supply Return Filter Size a Porsche. As a new home designer, I am extremely excited to be now exploring the impact of the Smart Duct System on my floor designs. 15 k 30 k 45 k 60 k 75 k 13.50 13.50 13.50 15.75 15.75 12.50 12.50 12.50 14.75 14.75 11.50 11.50 11.50 13.75 13.75 13 x 24 13 x 24 13 x 24 15 x 24 15 x 24 90 k 21.20 20.00 15.25 17 x 24 105 k 120 k 21.20 21.20 20.00 20.00 15.25 15.25 17 x 24 17 x 24 This is a revolution in improved HVA performance offering full home comfort and energy effi ciency to the homeowners. Doug Tarry Jr Doug Tarry Homes ELETRIAL DATA DIMENSIONS (centimeters) Furnace size A abinet width B Supply Return Filter Size INPUT 15K 30K 45K 60K 75K 105K 120K 15K OMPAT SHIP WEIGHT (LB/KG) 79 / 35.8 115 / 52.2 116 / 52.6 119 / 54.0 136 / 61.7 138 / 62.6 161 / 73.0 171/ 77.6 15 k 30 k 45 k 60 k 75 k 34.29 34.29 34.29 40.00 40.00 37.46 37.46 36.83 36.83 33.02 x 60.96 33.02 x 60.96 33.02 x 60.96 38.10 x 60.96 38.10 x 60.96 90 k 53.34 50.80 41.91 33.02 x 60.96 105 k 120 k 53.34 53.34 50.80 50.80 41.91 41.91 43.18 x 60.96 43.18 x 60.96 MAXIMUM ONSUMPTION (Amps / breaker size) SUPPLY MODULATING 8.6 / 10 10.7 / 15 10.7 / 15 12.6 / 15 15.6 / 20 15.6 / 20 19.0 / 20 19.0 / 20 2 STAGE EM - - - 12.6 / 15 15.0 / 15 15.0 / 15 19.0/ 20 19.0/ 20 2 STAGE PS - - - 15.3 / 20 15.3 / 20 15.0 / 15 19.1 / 20 19.1 / 20 1 STAGE X13 1 STAGE PS - - - 11.9 / 15 11.9 / 15 13.5 / 20 16.6 / 20 16.6 / 20 - - - 15.9 / 20 15.9 / 20 15.5 / 20 19.6 / 20 19.6 / 20 115 Volts - 60 Hertz - 1 Phase

HVA in a box The right airfl ow is as important in considering the load per room, as the BTUs either in a new effi cient home or for effective renovation. The Smart Duct System can provide a system leakageage of 5% or less. In combination with the controls we developed at Dettson for this specifi c system, our HVA in a box solution is designed to run at a low-to-medium velocity and low-to-medium static pressure, offering quiet thermal comfort for homeowners and system effi cacy for the effi cient home. Our vision behind this system allows the builder to eliminate bulkheads and added expenses, while optimizing fl oor plan designs. High Performance homes benefi t from the longer cycles offered by the lower airfl ow in combination with the right BTUs. Our system offers a better air mix from the diffusor that is installed high wall, which delivers a more comfortable environment and better energy performance from the HVA system. Another benefi t of this concept includes zoning capabilities. Overall this system greatly improves the air distribution performance avoiding cold or warm rooms thus positively impacting homeowner comfort. Standard register throw Smart Duct System throw Benefits from the Smart Duct System For the builder: A uniform system from home to home; Less expensive to install being less labor intensive; Lower duct leakage below 5%, balanced room to room, fewer callbacks; Easier to install in conditioned space. For building science: Provides a solution to the building codes and voluntary program challenges; Raises the bar on old rule of thumbs for load assessments; Easy-to-design duct system. For the homeowner: Better air mix throughout the home through better distribution (addressing hot or cold rooms); System designed for central HVA effi cacy for lower energy consumption; Quieter environment in each room; Healthier home including humidity management; 35 db and less at the diffusor. For mechanical contractor: Provides a differentiator with a technical solution; Brings value-added features to builders; Ability to handle more job sites because of more effi cient and faster installs; Installation labour savings vs. traditional duct system; More consistent end product.