Model ID-441-C InGaAs Near Infrared Detector with Preamplifier and Thermoelectric Cooler Operating Instructions

Similar documents
Instruction Manual ID-442 Infrared Detector 442-1A Temperature Controller Preamplifier

Indium Gallium Arsenide Detectors

Photovoltaic Mercury Cadmium Telluride Detectors

Understanding total measurement uncertainty in power meters and detectors

The J22 and J23 series are high performance InGaAs detectors operating over the spectral range

G155PU001S. Pigtailed 14-PIN DIL Laser Diode with TEC. FLMS Min. Typ. Max.

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

MicroSL Silicon Photomultiplier Detectors

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

SECTION 1: STARTING 1.1 UNPACKING AND INSPECTION

XPIN -XT X-ray Detector Operation Manual

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications

DAWN Electronics, Inc.

818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)

Exercise 1: IR Transmission and Reception

818 Series Low-Power Detectors

Spectrum Detector, Inc.

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

CM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Table of Contents SECTION PAGE

Danfoss gas detection units

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

PM-200 Power Module Operating Instructions

DHM5150 Human Motion Sensor Module User Manual

Cooled Butterfly 980nm Pump Laser Module

Datasheet: K-22 LO Sensor

Product Specification

OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

IR detection module VPAC-1000F user's guide

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

Power Flame Incorporated

Model 3300 Technical Support and Installation Manual

Danfoss gas detection units

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

SEC 2000 Millenium Infrared Gas Detector

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Preamplifier Power Supply PPS-02 user's guide

Electro Optical Components, Inc Skylane Boulevard, Santa Rosa, CA Toll Free: 855-EOC

GAMMA RAY DETECTION PROBE MODEL SO16

CALIBRATION HOW IT WORKS

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

OFS IV Optical Fibre System

Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1

Single Channel Heater Controller

Four channel video link For low cost video transmission

Reflective Optical Beam Smoke Detector User Guide

PORTABLE DEW POINT MONITOR

RTD TEMPERATURE SENSING SYSTEM

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

Models S310 & S310D Laser Power and Energy Meters Setup and Operating Procedures

PureGain TM 2600 Variable Gain EDFA for Metropolitan Networks

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

HUM-M2 Humidity Sensor Module Description

CALIBRATION HOW IT WORKS

Model 4001 Series Single Channel Controller

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

T3/E3 Fiber Optic Line Drivers

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

FlameGard 5 MSIR HART

FIRERAY 5000 range USER GUIDE

Advanced Test Equipment Rentals ATEC (2832) LS-1310/1550 Laser Source. Service Information Sheet.

IR detectors user's guide

User s Guide. CN616 Series 1 4 DIN Economical 6-Zone PID Temperature Controllers. Shop online at omega.com SM

Model 4880 Status Output Display Module Manual

DSP EC Pro. Advanced, Digital Gamma-Ray Spectrometer for HPGe Detector Systems

EXcon zone control. Control for up to 4 individual zones _ fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

EOTec 2C32 Installation Guide

An Ambient-Light-Ignoring Infrared Active Motion Detector

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

Intelligent Fire Detection and Visual Guided Evacuation System Using Arduino and GSM

OVEN INDUSTRIES, INC.

Infrared Detectors. Special-Sensors for. Automation

Instruments Designed for POF & Fibre Optic Cable Testing

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

PAC1500Xi PORTABLE APPLIANCE CHECKER

APPLICATION NOTE. 1. Introduction Application Considerations

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Dual Channel Heater Controller

RTE-5/5B & RTE-9/9B Refrigerated Bath Circulators. NESLAB Manual P/N Installation, Operation and Service Manual

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

ESSEX ENGINEERING CORPORATION

GRID-EYE INFRARED ARRAY SENSOR

CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: _03. V-CEM5100 for waste gas velocity. TÜV Rheinland Energy GmbH

AM-806. Waste/Door Radiation Monitor OPERATIONS MANUAL

English. Italiano. Português. Françias. Español

Model 5306 FAST. FOCUSED. CONTROLLED. Infrared Heaters For Controlled Concentrated Heating. Infrared Heat. Instantaneous Results.

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

detectors UltiMate 3000 Variable Wavelength Detectors

Transcription:

15 Discovery Way, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.piacton.com Model ID-441-C InGaAs Near Infrared Detector with Preamplifier and Thermoelectric Cooler Operating Instructions Ver 2.0

Contents I. Description II. Installation A. Mounting to Monochromator B. Electrical Connections III. Operation A. Setting Detector Tempeature B. Detector Output IV. Component Manufacturers Specifications and Instructions A. Detector Specifications B. Thermistor Specifications C. Thermoelectric Cooler Instructions and Specifications

I. Description The Princeton Instruments Model ld-441-c InGaAs near infrared detector assembly consists of a 3mm diameter InGaAs detector mounted in a sealed housing with a thermoelectric cooler and thermistor. The thermoelectric cooler is controlled by an optional external module (Model 442-1A) which allows adjustment of detector operating temperature. A preamplifier is built into the detector assembly and provides a positive voltage output to the incident near IR radiation. The detector is usable over the wavelength range of 800nm to 1700nm. II. Detector Installation The InGaAs detector assembly mounts to the Princeton Instruments Acton monochromator exit slit using the four cap screws provided. For maximum transfer of signal, the detector should be mounted directly to the monochromator slit housing and not spaced away from the slit by a filter assembly or other accessory. If provided, place the 442-1A temperature controller near the detector assembly. Attach the 9 pin connector of the interface cable provided to the rear of the temperature controller and connect the 9 pin round connector of this cable to the detector assembly. The temperature controller also provides the necessary voltages for the detector preamplifier. If the optional temperature controller was not ordered, a separate plug-in supply is provided for the preamplifier. It also has a 9 pin round connector which plugs into the detector assembly. Connect the BNC output from the detector assembly using the BNC cable provided to a readout system such as the Princeton Instruments NCL or other device capable of reading 0 to +10 Volts. III. Operation The InGaAs detector assembly is sensitive to near IR radiation in the wavelength range of approximately 800nm to 1700nm. For enhanced detectivity, the InGaAs detector can be cooled down to 20 degrees C. The detector is cooled by precisely controlling the current through the thermoelectric cooler mounted inside the detector case. The maximum thermoelectric cooler current is 1.2 amps. Also mounted inside the detector case is a thermistor which monitors the detector temperature. The 442-1A temperature controller provides the thermoelectric cooler current and monitors the thermistor resistance in a closed loop setup to maintain the detector at constant temperature. The operating temperature is set by first determining the thermistor resistance corresponding to the desired operating temperature.

A thermistor calibration table is listed with the component manufacturer s date in Section IV of this manual; a typical table is listed below. Refer to the data sheets provided in Section IV for the exact values. Temperature (deg. C) Resistance (K ohms) 25.0 1.12 0.0 2.84-10.0 4.30-20.0 6.77 Set the display mode selector to TEC CURRENT MAX SET and adjust the potentiometer on the right to a maximum of 1.2 Amps. Switch the Display Mode selector on the temperature controller to TEC TEMPERATURE SET and adjust the output control until the display reads the desired thermistor resistance. Switch the Display Mode selector to TEC TEMPERATURE. The display will indicate the actual thermistor resistance and should quickly match the value selected. Refer to the instruction manual in Section IV for further instructions on use of the temperature contoller. The InGaAs detector is operated in the photovoltaic mode for lowest noise performance. The preamplifier has a fixed gain to provide +10 Volts out for 1.0x10-6 Amps input.

IV. Component Manufacturers Specifications and Instructions ID441-C TEC Specifications: Number of stages: 2 TMAX ( C): 78 QMAX(Watts): 0.39 IMAX(Amps): 1.4 VMAX(Volts): 0.8 Nominal thermistor R (KΩ ): 1.25 ID441 DATA (VR=10mV) (VR=10mV) (1300 nm) Serial No. RS (MΩ ) C (pf) R (A/W)

ID-441 Responsivity Responsivity of Short Wavelength Enhanced InGaAs Photodiodes (FD1000WX and FD3000WX Photodiodes)