Snitcher. Installation Instructions

Similar documents
GSM 3G AUTO DIALLER PLUS

1. Functions of GPS locator ETLOC-30S 3

MOBILE CALL GSM Alarm System User s Manual

GSM RFID VOICE Alarm System

Memcom Emergency Telephone

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

1. Introduction. 2. Product overview

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation

GSM CAR ALARM SYSTEM USER S MANUAL

Security GSM Alarm System

3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

Ontech GSM 9040/50. Reference Manual English -1 -

Wireless Alarm system s manual

SA 2650 Kit User Manual

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

GSM 3G AUTO DIALLER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

2G & 3G GSM Portable PIR Alarm

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

2G & 3G GSM Door Contact Alarm

1. User features of the GSM dialer

System. For a better understanding of this product, please read this user manual thoroughly before using it.

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

Fitting instructions

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

IP & SMS Alarm Communicator

Mobeye CM2410 GSM fire alarm communicator


AG HOME ALARM Quick Start Guide

Intelligent Wireless GSM Alarm System

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual

GPS Vehicle Tracker (GPS+GSM+SMS/GPRS) User Manual (V1.0)

GSM PROTECT ANTI-THEFT ALARM WITH GPS TRACKING & MOBILE PHONE ALERTS

EM8710 GSM Alarm System Starter Kit

GSM PERIMETER & INTRUDER ALARM

Elderly Care Alarm System

2G & 3G GSM Wireless Beam Alarm

My Visonic SMS App User Guide

USER MANUAL Mobeye ThermoGuard CM2200

DYGIZONE GJD910 Lighting Controller & Enunciator

Manual GPRS Data Logger PCE-GPRS 2

SMART SWITCH TECHNOLOGIES. SmartSwitch Yacht-Guard Model SMS-8 Vessel System Monitor Installation Manual

GSM SMS Controller GSM SMS Alarm Unit S130 S140 S150. User Manual

Smart GSM/GPS car alarms

EZY SWITCH. SMS-IRR-4 System Monitor Installation Manual

SMS GSM Alarm Messenger

With Magictrl, you can control MatiGard anytime & anywhere via your smartphone, even without data network.

GSM WIRELESS ALARM SYSTEM Model: GSM-0308W

Galaxy Flex V3. User Guide. Honeywell Security. This user manual is located at

LevelSET S GSM Functionalities Instructions for Commissioning and Use

Pandora Smart Pro QUICK START GUIDE. model

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard.

PiSector GSM Cellular Wireless Alarm System

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

GSM Emergency Alarm. User s Manual. For a better understanding of this porduct,please read this user manual thoroughly before using it.

User Manual & Setting Instructions

USER S MANUAL HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY

DESCRIPTION INSTALLATION

It is necessary to match all peripherals with the EVOLVEO Alarmex main unit before the first use. For safety reasons, they are not factory paired.

Kwêbeam GSM/Interface/Repeater Module

User Manual (LS-GSM-006)

Inner Range FE3000S. Serial GSM Modem. P/No: INSTALLATION MANUAL

EURO 46 V10 User Manual

WiFi GSM APP Smart Home Security System

Monitoring Solutions

SC-F3G User Manual 1.0

Contents. Contents

DigiAir QUICK GUIDE & INSTRUCTION MANUAL

T4000 Security Communicator

D3D Wi-Fi GSM Smart Alarm System -User Manual

SA 2700 Kit User Manual

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

Contents. Glossary

Sentient. Downloader Manual D4854

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

USER MANUAL CEF AP28 CONTROL PANEL

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

IRIS Touch Firmware Enhancements and Additions from Version to Version

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Installation manual: CA-1803BT Athos mode 1 for cars without an original remote control for central locking

abode Web app Functionality

WHAT HAPPENS NEXT FOR ADT SMART BUSINESS CUSTOMERS

MT-S20 USER S MANUAL. (Motor Alarm &Tracker) (Version 1.4)

New Silent Alert Fire Safe System

Memcom + Emergency Telephone

SolarSET GSM SolarSET GSM with a Beacon

Watchguard WGAP864 User Manual

MyNice Welcome to your Nice World. The intelligent solution for the integrated management of the alarm system and of the home s automations.

HELPY QUICK-TL GSM INTL

PERMACONN PM1030 Includes DI300. Installation Manual

GSM House Alarm System. User Manual. Ver 1.20 Date Issued:

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

PART NO: TSMS. Designed in Australia by. Instruction Manual. Factory Car Alarm Upgrade Providing Alarm Notification Via SMS Messaging N517


with internal sensor (channel 1) with an external sensor (channel 2) A-Editor software, Professional AK20 version (not for version AK4)

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

Transcription:

Snitcher Installation Instructions IMPORTANT: Register your Snitcher Text alert system onboard SIM before installing and/or powering up the system (see setup and operating instructions). The system must be commissioned within 24 hours of Registration. Unit location As the control unit has a remote antenna the unit can be mounted within frame work. The control unit has its own movement sensor, it is at its most effective if mounted on a flattish surface. The control unit can be fixed into position using cable ties or by using the molded pre-holed feet. When positioning take into account cable routing and access to the required connections (see: Wiring). Do not mount close to or onto machines exhaust or other components likely to generate excessive levels of heat, this will damage your Snitcher. Antenna location The antenna can be fixed into position with either its own self adhesive backing or with suitable cable ties. The antenna must not be mounted on any metal surface and must be external to any metal framework where possible. Do not mount close to or onto machines exhaust or other components likely to generate excessive levels of heat. The antenna cable length has been tuned and must therefore not be cut back or modified, and where possible try to avoid running alongside the existing motorcycle wiring loom. When the screw connection to the main unit has been made it should be protected by using self amalgamating weather resistant tape or a suitable sized heat shrink.

Wiring Basic installation Red Yellow Black Constant live Ignition controlled live Earth The basic wiring of the Snitcher requires access to a constant live, an ignition controlled live and an earth. We recommend that both the connections to the constant live and the ignition controlled live are on the fused side of each respective circuit, and that the switched live is taken from a non-run critical circuit, (e.g. the brake light circuit). The earth taken should be an electrical earth not a mechanical or frame earth. Soldered joints are recommended, protected with self amalgamating weather resistant tape or a suitable sized heat shrink. Advanced installation Green Triggered via the alarm If you have an alarm system fitted to your machine and it has an extra siren output it is possible to link this to the Snitcher so the alarm can be used as an extra trigger input. The Snitcher has to be configured to match the type of output coming from the alarm (positive or negative). The Datatool alarm system gives a POSITIVE output when sounding and this is the default setting for the Snitcher. Should your alarm system have a negative extra siren output the Snitcher can be adjusted to respond to this via a text message. It is best to commission the Snitcher and then configure the input trigger before connecting the Green wire to the siren output of the alarm. Texting #INN to the Snitcher changes the trigger input required by the unit to NEGATIVE. Texting #INP to the Snitcher reverts the trigger input required by the unit back to POSITIVE. Blue Optional siren negative (Pt. No. 02012004) This wire can be connected to a supplementary siren. A positive connection is made to the positive side of the siren (normally a red wire on the siren) and the blue should be connected to the negative side of the siren (normally a black wire on the siren). The Snitcher will sound the siren on command. The maximum output from this wire is 400mA. If the wire is not used it should be fully insulated to prevent shorting.

Registering The On Board SIM Snitcher Set Up & Operating Instructions Before calling to register, have your Snitcher paperwork and a pen to hand and be aware that a memorable password will be required. The SIM card within this unit is activated in the same way as you would activate any pay as you go mobile phone SIM. Please call 0800 0797979 to register your the SIM. Tell the operator you want to register a pay as you go SIM card. The operator will talk you through your registration step by step and also register your Orange top up card. Once registered and installed, the Snitcher will automatically log onto the network and deal with all the initiation text messages Orange send. Be sure to record your allocated mobile number and account password in the appropriate boxes at the rear of this of the user guide. Getting Started Your own mobile is referred to as the host and this must be used when communicating with the Snitcher. Once the registration has been completed and the unit fully installed, switch on the motorcycles ignition for thirty seconds. Now text #x5990a* from the host mobile (the pin code as found on the rear cover of your user guide). If successful the Snitcher will respond with a test message to the host reading Unit Programmed Successfully. Any text information sent by the Snitcher will now be sent to the host mobile. Reading Trigger Texts And Sending Instructions The Snitcher arms fifteen seconds after the ignition supply has been turned off. Any trigger from then will be sent to the host mobile as a text alert (see table 1 for an explanation of the received text). The Snitcher can also be programmed and triggered from the host (see table 2 for an explanation of the commands). This can only be done within thirty minutes of the ignition supply being switched off, within thirty minutes of the last text message or any time that the ignition supply is turned on. The unit can only receive any communication within thirty minutes of each of these actions as after this period of time it returns to a sleep mode, this mode will not affect the response to any trigger. For security reasons, please test the system every 3 4 months by triggering movement detection or the external input.

Text warning messages (Table 1) Message No. 1 Event Message Cycle How To Reset Motorcycle movement. 2 Trigger Input 3 Motorcycle battery level drops below ten volt threshold ALERT! Movement Sensor Activated. ALERT! Alarm Activation ALERT! Low Battery If movement continues this message will be sent a maximum of three times at thirty second intervals. If trigger input continues this message will be sent a maximum of three times at thirty second intervals. This message will only be sent once. The Snitcher will then switch itself off to save battery power Switch ignition supply on OR text RESET to Snitcher. Switch ignition supply on OR text RESET to Snitcher. Recharge motorcycle battery Please note: In the event of three movement or trigger output alerts the Snitcher will automatically switch on the GSM modem and enter Lock Mode. This mode increases the accuracy of the location service (see www.datatool.co.uk for details) and will allow the Snitcher to constantly update its location. Lock Mode can be cancelled by simply switching the ignition supply on or by texting RESET from the host. Text commands (Table 2) Text Action #x5990a* This is the factory set pin number for your Snitcher. When sent, this will initiate the sending mobile as the host. #x5990a*---- By substituting the ---- with your own chosen four digit number you can replace the factory set pin and personalize the Snitcher s pin number.? This will prompt a report on the signal strength. Values range from 0 to 31, 31 being the higher strength. A typical response is strength 7-15. OPN No siren output at any time. OPC Constant siren output. OPY Siren output for 30 seconds, pulsing 1 second on then 2 seconds off, then reverting to OPN. #MSY The Snitcher s internal movement sensor is enabled. #MSN The Snitcher s internal movement sensor is disabled. #MSH The Snitcher s internal movement sensor is set to its high sensitivity setting. #MSL The Snitcher s internal movement sensor is set to its lowest sensitivity. #ALN The Snitcher will ignore any input from the Green external input wire. #ALY The Snitcher will respond to any input from the Green external input wire. #INP The Snitcher is configured to respond to a POSITIVE trigger input from the Green wire #INN The Snitcher is configured to respond to a NEGATIVE trigger input from the Green wire #ALYC The Snitcher will trigger if the Green external input wire is disconnected from the external device. VALET The Snitcher will ignore the movement sensor and external input allowing the machine serviced. The unit will remain dormant until RESET has been text from the host. RESET This will clear VALET mode, the movement sensor and external input counters, the 30 second timers and switches off the #GSMP mode #GSMP The GSM module is switched on, this is for vehicle location only (see www.datatool.co.uk) The preset factory setting is #MSY (movement sensor enabled), #MSL (lowest sensitivity) and #ALY (external input enabled). #MSH is recommended for winter storage only.

Snitcher Frequently Asked Questions Snitcher will not respond to movement, why? : a. Check that the onboard SIM has been registered correctly and the account is in credit. b. The ignition must be turned off to allow the fifteen seconds before the system sets fully. c. The host mobile signal is weak or turned OFF. d. The internal movement sensor is turned off. Snitcher will not respond to the external trigger input, why? : a. As above a, b and c. b. The external input device has failed. c. The connection to the external input device has failed. How do I check the signal strength in the area? : a. Make a voice call to Snitcher, if the call diverts to voicemail as soon you call, the signal is poor. b. Text? to Snitcher and text back a signal strength if there is service. Is there a cost involved when Snitcher sends a message? : Messages from Snitcher in the U.K. are currently charged at the standard Orange rate of 12p per text (Please note this charge is controlled by Orange so may vary according to their service charges. The above charge was correct 01.10.05). Will Snitcher work when I am abroad? : Snitcher will roam, check with Orange for details on coverage and roaming charges. Can I change the Snitchers pin code to a more memorable number? : The four numbers in the pin code can be changed, text the current pin number complete followed by the four new numbers to Snitcher. Eg. #X5990A*1234 will change the pin code to #X1234A* Is the text case sensitive? : The text can be sent in upper or lower case. The message must just be constructed correctly without any spaces. If I change my host mobile how will I know if it has been programmed correctly? : After you have texted your pin code to the Snitcher you will receive a message saying unit programmed successfully. I you do not receive the confirmation text, check and resend the pin code. What if I loose my TOP UP card? : TOP UP cards are available from any Orange top up outlet, then call Orange direct on 07973 100 450 to register the new card. How can I find out how much credit I have left on the Snitcher? : Call Orange direct on 07973 100 451 and listen to the automated service.

ADD BIKE LOCATION TO YOUR TEXT ALERT FOR 29.99 BUY ON-LINE @ www.datatool.co.uk or call 0870 746 1905/06 Datatool (UK) Ltd, C/O MST Locate Ltd Unit 1, 202 Pershore Road South Kings Norton Birmingham B30 3EU U.K Tel 0870 746 1905/06

Snitcher Registration information To register your SIM card call Orange Tel No. 08000 79 79 79 IMPORTANT: Register your Snitcher onboard SIM before installing and/or powering up the system (see setup and operating instructions). The system must be commissioned within 24 hours of Registration. Please record your Snitcher telephone number here This number will be issued by Orange as you register Personal password Identity code number IMEI Number SIM Card Number