User manual 2017 Koninklijke Philips N.V. All rights reserved.

Similar documents
User manual. Always there to help you. Question? Contact Philips AC3252 AC3254 AC3256

Register your product and get support at AC4002 AC4004. User manual

Register your product and get support at. AC4006. User manual

Register your product and get support at. AC4076. User manual

Register your product and get support at AC4091. User manual

Always there to help you. Register your product and get support at AC4373 AC4375. Question? Contact Philips.

Always there to help you Register your product and get support at AC4030/00 AC4030/10 Question? Contact Philips User manual

1. Important safety information

VK-6008D. User Manual

NANO HIPPO 50WH Air Purifier

AIR PURIFIER MODEL NO: APA240 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: GC1114

FR EN NL DE ES PT IT TR RU UK

Note: Verify that plastic bags are removed from filters, if equipped or installed, before first use (see page 8) CONTENTS

Comefresh CF-8608 Air Purifier

Coway Air Purifier AP-1008DH

Please read this manual carefully before use to ensure proper usage and save

Contents. 7 Notices 21 Electromagnetic fields (EMF) 21 Recycling Important 4

Coway Air Purifier AP-1008BH/CH

THANK YOU FOR PURCHASING THE LV-PUR131 TRUE HEPA AIR PURIFIER BY LEVOIT. GET STYLE #LevoitLove #LevoitLifestyle

Contents. 1 Important 4 Power failure backup function 7 Electromagnetic fields (EMF) 7

HP8180

English. Important Read this user manual carefully before you use the appliance and save it for future reference.

Register your product and get support at HP4944 HP4945. EN User manual

User Manual Manual del usuario Guide d utilisation. Blueair 400 Series

HD9216 HD9217. User manual

BestAir. Instruction manual

WINIX AIR PURIFIER. User Manual. Tower XQ

Straightener. EN User manual. Register your product and get support at

BestAir. Instruction manual

Always here to help you. Register your product and get support at GC4400 series. User manual

DESCRIPTION OF THE APPLIANCE SAFETEY OPERATION CAUTION MAJOR COMPONENTS. Features

THANK YOU FOR PURCHASING THE LV-H133 TOWER HEPA AIR PURIFIER BY LEVOIT! GET STYLE #LevoitLove #LevoitLifestyle

Model: AW600. Triple Action Humidifier. Winix Inc. 120 Prairie Lake Road U nit E East Dundee, IL USA

Hairdryer. Register your product and get support at HP8251 HP8250. User manual

MeacoClean CA-HEPA 119x5 Air Purifier

3 C D E 1 I A B F G H J K M L

Styler. Register your product and get support at HP4674. User manual

Air Purification System. Instruction Book CLI-AP20

OPERATING INSTRUCTIONS

THE BEAUTY OF SIMPLICITY USER MANUAL

Reverse Cycle Split System Air Conditioner

HEPA Air Purifier with Ion Flow Technology

CONTENTS CONTROLS 3-STAGE AIR PURIFICATION. X This product is suitable for 120V only. User Manual. Odor sensor. ➌ PlasmaWave

WHYNTER Eco Pure Air Purifier

DXAPV3N. Air Purifier. With. Enviro-neutralising Technology DXAPV3N

WINIX AIR CLEANER. User Manual HR950, HR951

Instruction Manual FEEL THE ENERGY. FEEL THE FRESHNESS.

HD

OWNER S MANUAL. Air Purifiers ROOM AIR PURIFIER. Operating and Servicing Instructions IMPORTANT: READ CAREFULLY BEFORE ASSEMBLY AND USE

AIR PURIFIER WITH GERMICIDAL UV LIGHT

Blueair Pro User Manual

Protect your lung health

Series HD9720-HD9727

Air Purification Unit MODEL 300/RHO2 USER GUIDE. Because You Care, Clean the Air

TPP440. owner s guide. air purifier with uv light. air purifier with uv light TP

instructions for use Air Purifier with ionizer _00/

FU-Z31E AIR PURIFIER OPERATION MANUAL PETUNJUK PENGOPERASIAN AIR PURIFIER. No. Reg. : 03/DJ-ILMEA/MG/I/2000. Free standing type Tipe Berdiri

Air Purifier H201 Air Purifier H301 INSTRUCTION MANUAL

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

Series HD HD9741. User manual

LOCK H M L REPLACE SLEEPING ANTI-POLLEN IONIZER UV-LAMP. User Manual

OVHM80 Max Air Purifier

Triple Action Humidifier Model: AW600

Register your product and get support at Hairdryer HP8260. User manual

English 6 Dansk 14. Ελληνικα 31. Français 55 Italiano 63. Norsk 79 Português 86 HP4674

TOWER AIR PURIFIER FOR THE FOLLOWING MODEL : EE-5067

Welcome to a Healthy Home

INSTRUCTION MANUAL. Remember to register your air purifier at: Multi-Tech 8500 Air Purifier

AirInstinct Air Purifier

AirPurifier LET S GET STARTED ACAMV101

7. CARE AND MAINTENANCE

Model & Replacement Pre-Filter Information Model Pre-Filter F Hunter Fan Company

The Easy To Use. Quick Start Guide To Pressure Cooking. For Models #EPC640, EPC650, EPC660, EPC640D, EPC650D & EPC660D

ELECTRIC HEATER WITH CARBON FIBER HEATING ELEMENTS

with plasma ioniser and Remote Control USER MANUAL

FU-W28J AIR PURIFIER OPERATION MANUAL. Plasmacluster is a trademark of Sharp Corporation. Free standing type ENGLISH

Dual-Hose Portable Air Conditioner User Manual

USE AND CARE GUIDE WALL MOUNTED HOOD

METAL CERAMIC FAN HEATER

Owner s Manual Super-Slim Four-Way Cassette

Instruction Leaflet AIR PURIFIER WITH AER1 TM TOTAL AIR FILTERS. pure indoor living. filter series MODEL: BAP9700-CN

FU-W53J AIR PURIFIER OPERATION MANUAL. Plasmacluster is a trademark of Sharp Corporation. Free standing type ENGLISH

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

Owner s Manual models HHPL & HHPM

USER MANUAL EAP120HC. Unit 2, The Nursery Berristow Lane South Normanton Derbyshire, DE55 2FX

User Manual C555. Model. Use & Care Guide

SAFETY INSTRUCTIONS. General Safety Instructions. Safety Instructions Operating Instructions Troubleshooting Tips Customer Service

USE & CARE INSTRUCTIONS

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

PA / PA-PRO PORTABLE AIR PURIFIER Instruction Manual

ADORABLE Air Purifiers

TOWER AIR PURIFIER FOR THE FOLLOWING MODEL : EE-5068

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

9 LITRE DESICCANT DEHUMIDIFIER INSTRUCTION MANUAL

Air conditioner. User manual. Wireless Remote Control AR-EC03E/EH03E/EC03M/EH03M. English 1

IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS AIR PURIFIER

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

PLUG-IN PERSONAL CERAMIC FAN HEATER

Induction Cooktop Product Guide (IC200B)


Transcription:

1 2 AC2887, AC2882 A C B H I J K L M N O P Q AC2887 G D E F H I J K L M N O AC2882 User manual 2017 Koninklijke Philips N.V. All rights reserved. 4241 210 93661

3 4 5 6 23 24 25 26 29 30 3s 7 8 9 10 27 28 3s 11 12 13 14 31 32 33 3s 15 16 17 18 19 20 21 22 3s 3s 34 3s

Contents English 1 Important 2 Safety 2 2 Your air purifier 5 Product overview (fig.a) 5 Controls overview (fig.b) 5 3 Getting started 6 Installing filters 6 7 Troubleshooting 13 8 Guarantee and service 15 Order parts or accessories 15 9 Notices 15 Electromagnetic fields (EMF) 15 Recycling 16 4 Using the appliance 6 Understanding the air quality light 6 Switching on and off 6 Changing the Auto mode setting 7 Changing the fan speed 7 Setting the timer 8 Using the light on/off function 8 5 Cleaning 9 Cleaning schedule 9 Cleaning the body of the appliance 9 Cleaning the air quality sensor 9 Cleaning the pre-filter (fig.v) 9 6 Replacing the filter 10 Understanding the healthy air protect lock 10 Replacing the filters (fig.y) 10 Filter force reset 11 Filter type change 11 EN 1

1 Important Safety Read this user manual carefully before you use the appliance, and save it for future reference. Danger Do not let water or any other liquid or flammable detergent enter the appliance to avoid electric shock and/or a fire hazard. Do not clean the appliance with water, any other liquid, or a (flammable) detergent to avoid electric shock and/ or a fire hazard. Do not spray any flammable materials such as insecticides or fragrance around the appliance. Warning Check if the voltage indicated on the appliance corresponds to the local power voltage before you connect the appliance. If the power cord is damaged, you must have it replaced by Philips, a service center authorized by Philips, or similarly qualified persons in order to avoid a hazard. Do not use the appliance if the plug, the power cord, or the appliance itself is damaged. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Child shall not play with the appliance. Cleaning and maintenance shall not be made by children without supervision. Do not block the air inlet and outlet, e.g. by placing items on the air outlet or in front of the air inlet. 2 EN

Make sure that foreign objects do not fall into the appliance through the air outlet. Caution This appliance is not a substitute for proper ventilation, regular vacuum cleaning, or use of an extractor hood or fan while cooking. If the power socket used to power the appliance has poor connections, the plug of the appliance becomes hot. Make sure that you plug the appliance into a properly connected power socket. Always place and use the appliance on a dry, stable, level, and horizontal surface. Leave at least 20cm free space behind and on both sides of the appliance and leave at least 30cm free space above the appliance. Do not place anything on top of the appliance. Do not sit or stand on the appliance. Sitting or standing on the appliance may lead to potential injuiry. Do not place the appliance directly below an air conditioner to prevent condensation from dripping onto the appliance. Make sure all filters are properly installed before you switch on the appliance. Only use the original Philips filters specially intended for this appliance. Do not use any other filters. Combustion of the filter may cause inreversible human hazard and/or jeopardize other lives. Do not use the filter as fuel or for similar purpose. Avoid knocking against the appliance (the air inlet and outlet in particular) with hard objects. Always lift or move the appliance by the handle on back side of the appliance. English EN 3

Do not insert your fingers or objects into the air outlet or the air inlet to prevent physical injury or malfunctioning of the appliance. Do not use this appliance when you have used indoor smoke-type insect repellents or in places with oily residues, burning incense, or chemical fumes. Do not use the appliance near gas appliances, heating devices or fireplaces. Always unplug the appliance after use and before cleaning, or carrying out other maintenance or replacing the filters. Do not use the appliance in a room with major temperature changes, as this may cause condensation inside the appliance. To prevent interference, place the appliance at least 2 meters away from electrical appliances that use airborne radio waves such as TVs, radios, and radio-controlled clocks. The appliance is only intended for household use under normal operating conditions. Do not use the appliance in wet surroundings or in surroundings with high ambient temperatures, such as the bathroom, toilet, or kitchen. The appliance does not remove carbon monoxide (CO) or radon (Rn). It cannot be used as a safety device in case of accidents with combustion processes and hazardous chemicals. If you need to move the appliance, disconnect the appliance from the power supply first. Do not move the appliance by pulling its power cord. Always cleanse your hands after changing the filters. 4 EN

2 Your air purifier Congratulations on your purchase, and welcome to Philips! To fully benefit from the support that Philips offers, register your product at www.philips.com/welcome. Product overview (fig.a) A B C D E F G Control panel Air quality light Air quality sensors NanoProtect filter HEPA Series 3 (FY2422)* NanoProtect filter AC (FY2420)* Pre-filter Front panel * Hereinafter referred to as air purification filter Controls overview (fig.b) For AC2887 H On/Off button I Light dimming button J Auto mode button K Display screen L General mode icon M Allergen mode icon N Bacteria&Virus mode icon O Fan speed button P Timer button Q Reset button For AC2882 H On/Off button I Auto mode button J Display screen K General mode icon L Allergen mode icon M Bacteria&Virus mode icon N Fan speed button O Reset button English EN 5

3 Getting started Installing filters Make sure that the appliance is unplugged before installing the filters. Before using the appliance, remove all packaging materials of the filters and place the filters into the appliance as described as follows. Make sure that the side with the tag is pointing towards you. 1 Remove all packaging materials of the air purification filters (fig.c). 2 Pull the bottom part of the front panel to remove it from the appliance (fig.d). 3 Press the two clips down and pull the pre-filter towards you (fig.e). 4 Put the unpacked air purification filters back into the appliance (fig.f). 5 Put the pre-filter back into the appliance (fig.g). Make sure that the side with the two clips is pointing towards you, and that all hooks of the pre-filter are properly attached to the purifier. 6 To reattach the front panel, mount the panel onto the top of the appliance first (1). Then, gently push the panel against the body of the appliance (2) (fig.h). 4 Using the appliance Understanding the air quality light Air quality light color Blue Blue-Purple Purple-Red Red Air quality level Good Fair Poor Very poor The air quality light automatically goes on when the appliance is switched on, and lights up all colors in sequence. In a short time the air quality sensors select the color that corresponds to the ambient air quality. Switching on and off 1 Put the plug of the appliance in the power socket. 2 Touch to switch on the appliance (fig.i). The appliance beeps. The appliance operates under the General mode by default. After measuring the air quality for a short time, the air quality sensor automatically selects the color of the air quality light. For AC2887, " " displays on the screen when the appliance is warming up. After measuring the particle matters in the air, the appliance goes to auto mode with displayed on the screen (fig. j). 6 EN

For AC2882, after measuring the particle matters in the air, the appliance goes to auto mode with displayed on the screen (fig.k). 3 Touch and hold for 3 seconds to switch off the appliance. After the appliance is switched off by the on/off button, if the plug is still in the power socket, the appliance will operate under the previous settings when it is switched on again. Changing the Auto mode setting You can choose the General mode ( ), the Allergen mode ( ) and the Bacteria&Virus mode ( ). General mode A smart auto-setting that automatically adjusts the air purifier s settings to the ideal level. Touch the Auto mode button to select the General mode (fig.k). Auto ( ) and display on the screen. Allergen mode The specially designed Allergen mode can effectively remove common allergens such as pollen and pet dander. Touch the Auto mode button to select the Allergen mode (fig.l). Auto ( ) and display on the screen. Bacteria&Virus mode This specially designed mode can help remove particles which are the size of certain bacteria and viruses. Tested with Staphylococcus albus and Influenza A (H1N1) only. Touch the Auto mode button to select the Bacteria&Virus mode (fig.m). Auto (A) and display on the screen. Changing the fan speed There are several fan speeds available. You can choose the Sleep mode ( ), speed 1, 2, 3 or Turbo mode ( ). Sleep (SL) In Sleep mode, the appliance operates quietly under very low speed. Touch the fan speed button to select the Sleep mode ( ) (fig.n). In sleep mode, " " displays on the screen for one minute. After that,all the lights will go off and the display screen will be dimmed with" " displayed. You can turn on the lights manually by touching. Manual Touch the fan speed button repeatedly to select the fan speed you need (fig.p). English EN 7

Turbo (t) In Turbo mode, the appliance operates under the highest speed. Touch the fan speed button to select the turbo mode ( ) (fig.o). Setting the timer The timer function is only applicable for AC2887. With the timer, you can let the appliance operate for a set number of hours. When the set time has elapsed, the appliance will automatically switch off. Touch the timer button repeatedly to choose the number of hours you want the appliance to operate (fig.q). The timer is available from 1 to 12 hours. To deactivate the timer, touch the timer button repeatedly until "---"displays on the screen. Using the light on/off function The light dimming function is only applicable for AC2887. With the light dimming button, you can switch on or off the air quality light, the display screen and the function indicators if needed. 1 Touch the light dimming button once, the air quality light will be dimmed. 2 Touch the light dimming button again, the air quality light will go off. The display screen and the function indicators will still be on, but the lights will be dimmed with " " displayed on the screen. 3 Touch the light dimming button for the third time, all lights will be on again. If you have set the timer once, next time when you use the timer, it starts from the previous setting time. 8 EN

5 Cleaning Always unplug the appliance before cleaning. Never immerse the appliance in water or any other liquid. Never use abrasive, aggressive, or flammable cleaning agents such as bleach or alcohol to clean any part of the appliance. Only the pre-filter is washable. The air purification filter is not washable nor vacuum cleanable. Cleaning schedule Frequency When necessary When F0 displays on the screen Every two months Cleaning method Wipe the surface of the appliance with a soft dry cloth Clean the pre-filter Clean the air quality sensors Cleaning the body of the appliance Regularly clean the inside and outside of the appliance to prevent dust from collecting. 1 Wipe away dust with a soft dry cloth from the body of the appliance. 2 Clean the air outlet with a soft dry cloth. Cleaning the air quality sensor Clean the air quality sensor every 2 months for optimal functioning of the purifier. Clean them more frequently if you use the purifier in a dusty environment. When the humidity level in the room is very high, it is possible that condensation develops on the air quality sensor. As a result, the air quality light may indicate that the air quality is bad even though it is good. In this case you have to clean the air quality sensor or use one of the manual speed settings. 1 Clean the air quality sensor inlet and outlet with a soft brush (fig.r). 2 Remove the air quality sensor cover (fig.s). 3 Clean the air quality sensor, the dust inlet and the dust outlet with a lightly moistened cotton swab (fig.t). 4 Dry them with a dry cotton swab. 5 Reattach the air quality sensor cover (fig.u). Cleaning the pre-filter (fig.v) Filter alert light status F0 displays on the screen Follow this Clean the prefilter English EN 9

1 Pull the bottom part of the front panel to remove it from the appliance (fig.d). 2 Press the two clips down and pull the pre-filter towards you (fig.e). 3 Wash the pre-filter under a running tap. If the pre-filter is very dirty, use a soft brush to brush away the dust (fig.w). 4 Air dry the pre-filter. Make sure that the pre-filter is completely dry. If it is still wet, bacteria may multiply in it and shorten the lifetime of the pre-filter. Cleanse your hands after changing the filter. 5 Put the pre-filter back into the appliance (fig.g). Make sure that the side with the two clips is pointing towards you, and that all hooks of the pre-filter are properly attached to the purifier. 6 To reattach the front panel, mount the panel onto the top of the appliance first (1). Then, gently push the panel against the body of the appliance (2) (fig.h). 7 Touch and hold the reset button for 3 seconds to reset the pre-filter cleaning time (fig.x). 6 Replacing the filter Understanding the healthy air protect lock This appliance is equipped with the healthy air protect lock to make sure that the air purification filter is in optimal condition when the appliance is operating. When the filters are almost expired, the filter code displays on the screen to indicate that you need to replace the filters. If the filters are not replaced in 14 days, the appliance will stop operating and get locked. Replacing the filters (fig.y) The air purification filters are not washable nor vacuum cleanable. Switch off the appliance before replacing the filters. 10 EN

Filter alert light status A3 displays on the screen C7 displays on the screen A3 and C7 display on the screen alternately Follow this Replace the NanoProtect filter HEPA Series 3 (FY2422) Replace the NanoProtect filter AC (FY2420) Replace both filters 2 Touch and hold for 3 seconds to force reset the filter lifetime of the NanoProtect filter HEPA Series 3 (fig.{). 3 Code (C7) of the NanoProtect filter AC displays on the screen after the lifetime of the NanoProtect filter HEPA Series 3 has been reset(fig.}). 4 Touch and hold for 3 seconds to force reset the filter lifetime of the NanoProtect filter AC and exit the filter force reset mode (fig.~). English 1 Take out the expired air purification filter according to the filter code displayed on the screen, and gently put the expired filter into the trash bin (fig.z). Do not touch the pleated filter surface, or smell the filters as they have collected pollutants from the air. 2 Remove all packaging material of the new filters (fig.c). 3 Place the new filters into the appliance (fig.f). 4 Touch and hold the reset button for 3 seconds to reset the filter lifetime counter (fig.{). Cleanse your hands after changing the filter. Filter force reset 1 Touch and simultaneously for 3 seconds to enter the filter force reset mode (fig. ). Code (A3) of the NanoProtect filter HEPA Series 3 displays on the screen. Filter type change 1 Touch and simultaneously for 3 seconds to enter the filter type change mode (fig. ). Code (A3) of the NanoProtect filter HEPA Series 3 displays on the screen. 2 Touch to select the filter code of the new filter you will use (fig.). 3 Touch and hold for 3 seconds to confirm the filter code of the new filter (fig. ). After you have selected the filter code of the new filter using the button, if you do not touch any other buttons in 10 seconds, the appliance will automatically confirm the filter code of the new filter. 4 Code (C7) of the Nanoprotect filter AC displays on the screen after the first filter type has been changed(fig.}). 5 Touch to select the new filter code of the second filter (fig.). 6 Touch and hold for 3 seconds to confirm the filter code of the EN 11

second filter and exit the filter type change mode (fig. ). After you have selected the filter code of the new filter using the button, if you do not touch any other buttons in 10 seconds, the appliance will automatically confirm the filter code of the new filter. Refer to the separate leaflet that comes with the filter for more information on different filter combinations for your choice. 12 EN

7 Troubleshooting This chapter summarizes the most common problems you could encounter with the appliance. If you are unable to solve the problem with the information below, contact the Consumer Care Center in your country. English Problem The appliance does not work even though it is plugged in. The appliance does not work even though it is switched on. The appliance accidentally powers off. The airflow that comes out of the air outlet is significantly weaker than before. The air quality does not improve, even though the appliance has been operating for a long time. The color of the air quality light always stays the same. Possible solution The filter replacement code has been displaying on the screen but you have not replaced the corresponding filter yet. The appliance will be locked if you keep using the expired filter. In this case, replace the filter and reset the filter lifetime counter. The filter replacement code has been on continuously but you have not replaced the corresponding filter, and the appliance is now locked. In this case, replace the filter and reset the filter lifetime counter. The appliance restarts automatically and goes to the previous mode when the power resumes. The pre-filter is dirty. Clean the pre-filter (see chapter "Cleaning"). One of the filters has not been placed in the appliance. Make sure that all filters are properly installed in the following order, starting with the innermost filter: 1) NanoProtect filter HEPA Series 3; 2) pre-filter. The air quality sensor is wet. The humidity level in your room is high and causes condensation. Make sure that the air quality sensor is clean and dry (see chapter "Cleaning"). The air quality sensor is dirty. Clean the air quality sensor (see chapter "Cleaning"). EN 13

Problem The appliance produces a strange smell. The appliance is extra loud. The appliance still indicates that I need to replace a filter, but I already did. Error codes "E1", "E2", "E3" or "E4" displays on the screen. Possible solution The first few times you use the appliance, it may produce a plastic smell. This is normal. However, if the appliance produces a burnt smell, contact your Philips dealer or an authorized Philips service centre. The appliance may also produce an unpleasant smell when the filter is dirty. In this case, clean or replace the filter concerned. If the appliance is too loud, you can change the fan speed to a lower fan speed level. When using the appliance in a bedroom at night, choose the sleep mode. Perhaps you did not reset the filter lifetime counter. Plug in the appliance, touch to switch on the appliance, and touch and hold the reset button for 3 seconds. The appliance has malfunctions. Contact the Consumer Care Center in your country. 14 EN

8 Guarantee and service 9 Notices English If you need information or if you have a problem, please visit the Philips website at www.philips.com or contact the Philips Consumer Care Center in your country (you find its phone number in the worldwide guarantee leaflet). If there is no Consumer Care Centre in your country, go to your local Philips dealer. Order parts or accessories If you have to replace a part or want to purchase an additional part, go to your Philips dealer or visit www.philips.com/ support. If you have problems obtaining the parts, please contact the Philips Consumer Care Center in your country (you can find its phone number in the worldwide guarantee leaflet). Electromagnetic fields (EMF) This Philips appliance complies with all applicable standards and regulations regarding exposure to electromagnetic fields. Compliance with EMF Koninklijke Philips N.V. manufactures and sells many products targeted at consumers, which, like any electronic apparatus, in general have the ability to emit and receive electromagnetic signals. One of Philips' leading Business Principles is to take all necessary health and safety measures for our products, to comply with all applicable legal requirements and to stay well within the EMF standards applicable at the time of producing the products. Philips is committed to develop, produce and market products that cause no adverse health effects. Philips confirms that if its products are handled properly for their intended use, they are safe to use according to scientific evidence available today. Philips plays an active role in the development of international EMF and safety standards, enabling Philips to anticipate further developments in standardization for early integration in its products. EN 15

Recycling Do not throw away the product with the normal household waste at the end of its life, but hand it in at an official collection point for recycling. By doing this, you help to preserve the environment. Follow your country's rules for the separate collection of electrical and electronic products. Correct disposal helps prevent negative consequences for the environment and human health. 16 EN