P R O D U C T D ATA S H E E T

Similar documents
P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

TOC-20 SERIES. Refrigerant Gas Monitor. Installation and Operation Manual Version 3 IGD OLIVER CH4 NO. Document Ref: T20-V3

IGD. O p e r a t i o n a n d M a i n t e n a n c e V International Gas Detectors. Triton House Crosby Street Stockport SK2 6SH England

P R O D U C T D ATA S H E E T

IGD.CO.UK

APPLICATION DATA SHEET

APPLICATION DATA SHEET

TOCSIN 750 SERIES OLIVER IGD. Triton House Crosby Street Stockport SK2 6TS England

CH4 SO2NO2. C O2 mount options. The controller has two SPCO relays as standard with three 4-20mA outputs and an RS485 Modbus UK Design And Manufacture

GAS DETECTION International Gas Detectors CH4 NO

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Two-Channel Gas Controller

APPLICATION DATA SHEET

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

CH4 NO TOC-30A-AN1 TOC-30A-ANN TOC-30A-AN2 TOC-30A-AN3. Pepper Road Bramhall Technology Park Stockport SK7 5BW England. International Gas Detectors

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

portable gas analyser

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 8000 Stationary gas detector (EC)

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

3M Oldham OLCT 100. Description. Fixed Gas Detector

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

User Manual. PolyGard Gas Controller MGC3. Two-Channel Analog Gas Controller Serial Number _E _0907. September 2007

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Sieger Apex. Flexibility that meets your requirements

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Recalibrate the way you look at gas detection

Inc Series Digital Gas Detector/Controller. Operation Manual

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Danfoss gas detection unit Type GD Heavy Duty

Warranty Registration

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

OLC(T) 100 FIXED GAS DETECTOR

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

SIL 2. Ultima X Series Gas Monitors CERTIFIED

SUPREMATouch. Modular Fire & Gas Detection System

Frequently Asked Questions

GAS DETECTOR ST400EC PART.NO

gas monitoring system

SUPREMATouch Modular Fire & Gas Detection System

Gas Controller Module GC-06

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Multi-Gas-Controller MGC2

GAS DETECTION SYSTEMS

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

SUPREMATouch. Modular Fire & Gas Detection System

G-TECTA TM. Portable Gas Detection Instruments

portable gas analyser

Dräger Polytron 8310 IR Detection of flammable gases and vapour

MERLIN RANGE GAS DETECTION EQUIPMENT

ALTAIR 5X Multigas Detector Product Specification

HART TOCSIN 903 SINGLE CHANNEL GAS DETECTOR USER INSTRUCTIONS. Oliver IGD Limited NEW WITH OPTIONAL. 4a Pepper Road Stockport SK7 5BW England

GAS DETECTION SYSTEMS

ZXSe Range Data Sheet

Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

YOUR PARTNER IN FIRE & GAS DETECTION

Danfoss gas detection units

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

Dräger Polytron 8720 IR Detection of carbon dioxide

Excellence in Level Measurement

ALTAIR 5X Multigas Detector

Leak detector for refrigerant gases R22, R134a, R410A, R407C...

Version Inc Series Digital Gas Detector/Controller. Operation Manual

RS Pro Infrared Temperature Sensor

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Dräger Polytron 5720 IR Detection of carbon dioxide

Carbon Monoxide CO Transmitter ADT-X3-1110

Danfoss gas detection units

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Hygrometer / Air Quality Meter

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Zareba Metro Gas Detector

Addressable Carbon Monoxide Detection, Monitoring & Ventilation System

Dräger QuadGard Control System

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Transcription:

Keyless RFID Control PGF- Effective Gas Safety Proving and Gas Detection Controller RFID Gas Proving, Ventilation Control & Gas Detection, off one panel Our range of gas proving systems can be used for: - Commercial Kitchens, Natural/LPG gas supplies e Cod - laboratory Gas Supplies including CO, O, etc. 3 - Low pressure ranges 0-50mBAR - High Pressure ranges up to 0-1000mBar and 0-10 Bar. 0 F-3 PG AS G ING OV PR Y CARD KE K LOC O UN T P TA OCK TO L TAP Ensuring gas pressure integrity prior to running. The system features industry first, contactless RFID cards, to start and stop the gas proving cycle. Furthermore the PGF- gas proving controller can be used to initiate fans in case of a build up of CO. Or it can ensure fans are running in fume cabinets etc. Features at a Glance RFID to Initiate the gas proving cycle Gas Detection System RFID cards to control access to the system As well as controlling ventilation and gas proving our systems also utilise addressable gas detection on the same panel, allowing you to have up to 4 detectors on 1 interlinked cable run. enabling you to detect over 400 gases and vapours and control a wide range of third party devices. Saving you time and money on reduced cabling and additional panel purchases. Flexible Power Supply Options Wall or Panel Mounting Relay Outputs as Standard 4-0mA Output as Standard RS485 Modbus as Standard Advantages of contactless RFID over keypads and key switches: Control up to 4 Devices as Gas Detectors or I/O Modules - RFID cards limit access to the panel. Meaning only senior staff can initiate the gas proving cycle. This gives you more accountability and security over the life safety system. LCD Display With Multi Colour Backlight, Green for all okay, Flashes Red on Alarm, Flashes Yellow on Fault etc E-Stop Input (System Configurable) - It is easier to replace (and more cost effective) RFID card then it is to reset the password or replace a whole new key switch. Dedicated Interlock to Fire Systems (System Configurable) Battery Backup Option - No Password handling/storage required. Easy and simpler to use with RFID than find the correct password/key. Displays current live gas readings and pressure readings HSCO SOCO SK 6SH Fax: +44 (0) 161 484 345 REF T10-LPG-3R-V1.06

Over 400+ Hazardous, Flammable & Refrigerant Gases Detected Standard Specifications Popular Gases Detected Power 110/V AC 50/60Hz 5W Standard 4V DC Option Construction ABS Display Lines x 8 Digit LCD Display Multi-Colour Backlight (Red-Alarm, Yellow-Fault, Blue-Normal) User Jog Wheel Option Select Outputs 3 off SPCO Relays 4A Non-Inductive User Configurable 1 off 4-0mA Linear Output User Configurable Other I/O Sounder 80dB @ 100mm (Mutable) RS485 Port Modbus Dedicated E-Stop Input Dedicated Fire System Interlock Inputs Up to 4 off Addressable Series Detectors or I/O Modules Note external Booster PSU may be required Temperature -5 to 55 Deg C Humidity 0-95% RH Non-Condensing Sealing IP54 Mounting Wall Mount, Panel Mount Kit Option, Duct Mount Kit Option Weight 840g O CO CxHx CO VOC s Pressure Reading Low Range 0-50 mbar High range 0-1000 mbar HS 0-10 Bar HSCO SOCO SK 6SH Fax: +44 (0) 161 484 345 REF T10-LPG-3R-V1.06

EC Declaration of Conformity Issuers name and address: Declares that the product listed as: Oliver Limited of Crosby St,, United Kingdom PGF- Gas Proving and Gas Detection Control Panel Are in conformity with the provisions of the following European Directive(s) when installed, operated, serviced and maintained in accordance with the installation and operating instructions contained in the product documentation. 004/108/EC 014/34/EU EMC Directive Low Voltage Equipment Directive (note not applicable to 4V DC Powered Versions) And that the standards and/or technical specifications referenced below have been applied or considered. En 60079-9-1:016 Explosive Atmospheres. Gas Detectors. Performance Requirements of Detectors for Flammable Gases. **conforms to** EN 61000-6--005 Electromagnetic Compatibility (EMC). Generic Standards. Immunity for Industrial Environments EN 61000-6-4-007/A1:011 Electromagnetic Compatibility (EMC). Generic Standards. Emission Standard for Industrial Environments. EN 61000-3-: 014 Electromagnetic Compatibility (EMC). Limits for Harmonic Current Emissions (Equipment Input Current 16 A per phase) EN 61000-3-3: 013 Technical File Reference PGF-TF9 Product Markings PGF- Oliver Limited Operate and Independently assessed ATEX/IECEX QAN. Quality Assurance Certificate Number ExVeritas 16PQAN0014 Quality Assurance Notification Number: 585 ExVeritas, Units 16-18, Abenbury Way, Wrexham Industrial Estate, Wrexham, UK, LL13 9UZ S/-serial number Oliver Limited operate an independently assessed Testing Agency: ISO9001:008 Quality Management System. TUV - SUD Octagon House Concorde Way Quality Management Certificate Number PO 15 5RL FS 646773 Fareham BSI Assurance UK LTD, Chiswick High Road, London W4 4AL UK TUV Certificates and reports can be checked on-line at https://www.tuev-sued.de/industry_and_consumer_products/certificates Issued on: 0th Feb 016 At Oliver Limited,, SK 6SH, United Kingdom Signature: Declaration of Conformity in accordance with EN ISO/IEC 17050-1:010 Name Andrew J Collier M.I.O.D Position: Managing Director Date: HSCO SOCO SK 6SH 0th Feb 016 Declaration Ref: PGF-DEC- Fax: +44 (0) 161 484 345 REF T10-LPG-3R-V1.06

REAR VIEW WALL MOUNTING POINT DETAILS 4.5mm SCREWS 3 1 REAR VIEW 14 Optional Battery Backup Kit PN 5686601 108 4 REAR ENTRY KCK OUTS 0mm DIA Note this module uses the same style enclosure as thepgf- and houses batteries and charge control. It is usually mounted below the PGF- and is supplied with all required connectors. SIDE VIEW PANEL MOUNT VERSION (CLAMP) 84 79 FRONT VIEW 18 PANEL CUT OUT 141 136 Optional Panel Mounting Kit PN 5686401 Sensor Options 01 BOTTOM VIEW 4 HOLES DIA 0mm 4 196 50 PANEL CUT OUT HSCO SOCO SK 6SH Gas Pressure Air Pressure Air Flow Flammable Gases Toxic Gases Temperature Humidity Motor Current Fax: +44 (0) 161 484 345 REF T10-LPG-3R-V1.06

1 Intelligent Systems Enhanced Safety For Operators 1 Gas Proving Controllers Can be Interlocked to Prevent Gas Supply If Ventilation is not Running or Not Running at a Sufficient Level ORDER CODES PGF- Controller 110/V AC PGF--RFID- Direct Airflow Measurement PGF- Controller 4V DC PGF--RFID-4 Controller Panel Mount Kit 5686401 Battery Backup Module 5686601 Replacement RFID Cards TOC-RFID-USER For Gas Detection and Room Status Indicator options refer to TOC- Series Gas Detectors Datasheets. 3 Direct Pressure Measurement 3 103 50 93 M0 Cable Entries 75 6mm Compression Fitting FLOW TRANSDUCER PN: 597501 Range 0.5-10M/S Analogue O/P Relay O/P 4V DC M0 Cable Entries HSCO SOCO PRESSURE TRANSDUCER PN: 598701 Range 0-50mBar Analogue O/P SK 6SH Fax: +44 (0) 161 484 345 REF T10-LPG-3R-V1.06

To compliment the PGF- TOC Series Gas Detectors provide accurate measurement of the background atmosphere to measure for a specific hazardous target gas. Clean lines and easy integration into existing or newly planned control systems make the TOC Series the safety engineers device of choice. Using the latest microprocessor addressable technology and TOC--AN software TOC Series detectors are a reliable long term monitoring solution. Refer to TOC- Room Status Indicator Data Sheet TOC-A-PHC With Gas Collector Fitted TOC Series Detectors are supplied pre-calibrated ready to use and directly connect to PGF-. Order Codes TOC-A Series Detectors Gas Standard Range Order Code Typical Cell Life Flammable Gases external sensor Flammable Gases internal sensor 0-100% LEL TOC-31A-PHC >3 Years 0-100% LEL TOC-A-PHC >3 Years Carbon Monoxide 0-100ppm TOC-A-CO >5 Years Oxygen 0-% Vol TOC-A-O 5 Years+ Nitric Oxide 0-00ppm TOC-A- > Years Nitrogen Dioxide 0-0ppm TOC-A- > Years Ammonia 0-100ppm TOC-A-NH3 > Years Chlorine 0-0ppm TOC-A-CL > Years Carbon Dioxide 0-5000ppm TOC-A-NDE Allows you to control third party devices with multiple I/O TOC-A-LCO >3 Years ** can help detect over 400 Hazardous and flammable gases and vapours, please call or email if you have other gas detection requirements** Order Codes Gas Collector Cone For TOC-A-PHC Calibration Adaptor TOC-31-PHC Calibration Adaptor TOC0/ Series Code 50006701 Code 401101E Code 595701 HSCO SOCO SK 6SH TOC-A-CO Fax: +44 (0) 161 484 345 REF T10-LPG-3R-V1.06