P R O D U C T D ATA S H E E T

Similar documents
P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

TOC-20 SERIES. Refrigerant Gas Monitor. Installation and Operation Manual Version 3 IGD OLIVER CH4 NO. Document Ref: T20-V3

IGD. O p e r a t i o n a n d M a i n t e n a n c e V International Gas Detectors. Triton House Crosby Street Stockport SK2 6SH England

IGD.CO.UK

APPLICATION DATA SHEET

CH4 SO2NO2. C O2 mount options. The controller has two SPCO relays as standard with three 4-20mA outputs and an RS485 Modbus UK Design And Manufacture

TOCSIN 750 SERIES OLIVER IGD. Triton House Crosby Street Stockport SK2 6TS England

APPLICATION DATA SHEET

GAS DETECTION International Gas Detectors CH4 NO

CH4 NO TOC-30A-AN1 TOC-30A-ANN TOC-30A-AN2 TOC-30A-AN3. Pepper Road Bramhall Technology Park Stockport SK7 5BW England. International Gas Detectors

APPLICATION DATA SHEET

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Two-Channel Gas Controller

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

portable gas analyser

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

SIL 2. Ultima X Series Gas Monitors CERTIFIED

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Sieger Apex. Flexibility that meets your requirements

gas monitoring system

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

SUPREMATouch Modular Fire & Gas Detection System

OLC(T) 100 FIXED GAS DETECTOR

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Gas Controller Module GC-06

GAS DETECTION SYSTEMS

Addressable Carbon Monoxide Detection, Monitoring & Ventilation System

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

3M Oldham OLCT 100. Description. Fixed Gas Detector

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

portable gas analyser

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Warranty Registration

GAS DETECTION SYSTEMS

Frequently Asked Questions

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Dräger Polytron 8000 Stationary gas detector (EC)

Zareba Metro Gas Detector

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Xgard. Fixed detectors For flammable, toxic or oxygen gases

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Inc Series Digital Gas Detector/Controller. Operation Manual

Leak detector for refrigerant gases R22, R134a, R410A, R407C...

GAS DETECTOR ST400EC PART.NO

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

G-TECTA TM. Portable Gas Detection Instruments

Multi-Gas-Controller MGC2

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

ALTAIR 5X Multigas Detector Product Specification

INSTALLATION AND OPERATING INSTRUCTIONS

BX444-Mc Gas Detector

Carbon Monoxide CO Transmitter ADT-X3-1110

TX6351 TX6352 Sentro 1 Universal Gas Detector Contents

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

Hygrometer / Air Quality Meter

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

ALTAIR 5X Multigas Detector

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Dräger Polytron 5720 IR Toxic Gas Detection

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

continuous emissions monitoring Combustion & Environmental Monitoring

ESD3000 ESD200 Combustible / Toxic Gas Detector

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

Safe Operation Manual. Honeywell IQ Force Gas Detector

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Danfoss gas detection unit Type GD Heavy Duty

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

HART TOCSIN 903 SINGLE CHANNEL GAS DETECTOR USER INSTRUCTIONS. Oliver IGD Limited NEW WITH OPTIONAL. 4a Pepper Road Stockport SK7 5BW England

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

LP GAS LEKAGE ALARM. M. G.. D. D. Wickramasinghe 1*, N. Abhayasinghe 2

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Danfoss gas detection units

2-WIRE SYSTEMS OLIVER IGD. 2-Wire. Version 3.2 T750-INST. Addressable. Triton House Crosby Street Stockport SK2 6SH England

Dräger Polytron 8720 IR Detection of carbon dioxide

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Intelligent Addressable Fire Alarm System

Transcription:

PGF- Effective Gas Safety Proving and Gas Detection Controller Gas Pressure Proving For use with Natural Gas LPG - or Laboratory gas supplies, both high and low pressure ensuring system integrity prior to running. Continuously Monitor For Gas Leakage Using State of the art LPG or Methane Gas detectors. Use gas leakage detectors to continuously monitor for gas leakage within the area. Control Mechanical Ventilation Rates Based on Room CO Levels. Control the area ventilation rate to minimise energy usage and ensure an optimum working environment. Interlock Mechanical Ventilation with the Gas Supply Valve Standard Specifications Power 110/V AC 50/60Hz 5W Standard 4V DC Option Construction ABS Display Ensure fume hood - cabinet extract fans are running before the gas supply is enabled. Features Flexible Power Supply Options Lines x 8 Digit LCD Display Multi-Colour Backlight (Red-Alarm, Yellow-Fault, Blue-Normal) Wall or Panel Mounting User Jog Wheel Option Select Relay Outputs as Standard Outputs 3 off SPCO Relays 4A Non-Inductive User Configurable 1 off 4-0mA Linear Output User Configurable 4-0mA Output as Standard Other I/O Sounder 80dB @ 100mm (Mutable) RS485 Port Modbus Dedicated E-Stop Input Dedicated Fire System Interlock Inputs Control up to 3 Devices as Gas Detectors or I/O Modules Up to 3 off Addressable Series Detectors or I/O Modules Note external Booster PSU may be required LCD Display With Multi Colour Backlight, Flashes Red on Alarm, Flashes Yellow on Fault etc Temperature -5 to 55 Deg C Humidity 0-95% RH Non-Condensing Sealing IP54 Mounting Wall Mount, Panel Mount Kit Option, Duct Mount Kit Option Weight RS485 Modbus as Standard E-Stop Input (System Configurable) Dedicated Interlock to Fire Systems (System Configurable) Battery Backup Option 840g HSCO SOCO SK 6TS Fax: +44 (0) 161 484 345 REF T10-LPG-3R-V1.06

EC Declaration of Conformity Issuers name and address: Declares that the product listed as: Oliver Limited of Crosby St,, United Kingdom PGF- Gas Proving and Gas Detection Control Panel Are in conformity with the provisions of the following European Directive(s) when installed, operated, serviced and maintained in accordance with the installation and operating instructions contained in the product documentation. 004/108/EC 006/95/EC EMC Directive Low Voltage Equipment Directive (note not applicable to 4V DC Powered Versions) And that the standards and/or technical specifications referenced below have been applied or considered. EN 61779-1:000 Electrical apparatus for the detection and measurement of flammable gases, general requirements and test methods. EN 5071:010 EN 61000-6--005 EN 61000-6-4-007/A1:011 EN 61000-3- A 014 EN 61000-3-3 013 Technical File Reference Electrical apparatus for the detection and measurement of combustible gases, toxic gases or Oxygen: requirements and tests for apparatus using software and or digital technologies. Excluding requirements for SIL PGF-TF9 Product Markings PGF- Oliver Limited Operate and Independently assessed ATEX/IECEX QAN. Quality Assurance Certificate Number ExVeritas 16PQAN0014 Quality Assurance Notification Number: 585 ExVeritas, Units 16-18, Abenbury Way, Wrexham Industrial Estate, Wrexham, UK, LL13 9UZ S/-serial number Oliver Limited operate an independently assessed Testing Agency: ISO9001:008 Quality Management System. TUV - SUD Octagon House Concorde Way Quality Management Certificate Number PO 15 5RL FS 646773 Fareham BSI Assurance UK LTD, Chiswick High Road, London W4 4AL UK TUV Certificates and reports can be checked on-line at https://www.tuev-sued.de/industry_and_consumer_products/certificates Issued on: 0th Feb 016 At Oliver Limited,, SK 6TS, United Kingdom Signature: Declaration of Conformity in accordance with EN ISO/IEC 17050-1:010 Name Andrew J Collier M.I.O.D Position: Managing Director Date: HSCO SOCO SK 6TS 0th Feb 016 Declaration Ref: PGF-DEC- Fax: +44 (0) 161 484 345 REF T10-LPG-3R-V1.06

REAR VIEW WALL MOUNTING POINT DETAILS 4.5mm SCREWS 3 1 REAR VIEW 14 Optional Battery Backup Kit PN 5686601 108 4 REAR ENTRY KCK OUTS 0mm DIA Note this module uses the same style enclosure as thepgf- and houses batteries and charge control. It is usually mounted below the PGF- and is supplied with all required connectors. SIDE VIEW PANEL MOUNT VERSION (CLAMP) 84 79 FRONT VIEW 18 PANEL CUT OUT 141 136 Optional Panel Mounting Kit PN 5686401 01 BOTTOM VIEW Sensor Options 4 HOLES DIA 0mm 4 196 50 PANEL CUT OUT HSCO SOCO SK 6TS Gas Pressure Air Pressure Air Flow Toxic Gases Temperature Humidity Motor Current Fax: +44 (0) 161 484 345 REF T10-LPG-3R-V1.06

1 Intelligent Systems Enhanced Safety For Operators 1 Gas Proving Controllers Can be Interlocked to Prevent Gas Supply If Ventilation is not Running or Not Running at a Sufficient Level ORDER CODES PGF- Controller 110/V AC PGF-- Direct Airflow Measurement PGF- Controller 4V DC PGF--4 Controller Panel Mount Kit 5686401 Battery Backup Module 5686601 For Gas Detection and Annunciator options refer to TOC- and TOC-0 Series Gas Detectors 3 Direct Pressure Measurement 3 103 50 93 M0 Cable Entries 75 6mm Compression Fitting FLOW TRANSDUCER PN: 597501 Range 0.5-10M/S Analogue O/P Relay O/P 4V DC M0 Cable Entries HSCO SOCO PRESSURE TRANSDUCER PN: 598701 Range 0-50mBar Analogue O/P SK 6TS Fax: +44 (0) 161 484 345 REF T10-LPG-3R-V1.06

To compliment the PGF- TOC Series Gas Detectors provide accurate measurement of the background atmosphere to measure for a specific hazardous target gas. Clean lines and easy integration into existing or newly planned control systems make the TOC Series the safety engineers device of choice. Using the latest microprocessor addressable technology and TOC--AN3 software TOC Series detectors are a reliable long term monitoring solution. Refer to TOC- Annunciator Data Sheer TOC-A-PHC With Gas Collector Fitted TOC Series Detectors are supplied pre-calibrated ready to use and directly connect to PGF-. Order Codes TOC-A Series Detectors Gas Standard Range Order Code Typical Cell Life external sensor internal sensor 0-100% LEL TOC-31A-PHC 0-100% LEL TOC-A-PHC Carbon Monoxide 0-100ppm TOC-A-CO >5 Years Oxygen 0-% Vol TOC-A-O >5 Years Nitric Oxide 0-00ppm TOC-A- > Years Nitrogen Dioxide 0-0ppm TOC-A- > Years Ammonia 0-100ppm TOC-A-NH3 > Years Chlorine 0-0ppm TOC-A-CL > Years TOC-31A-PHC Order Codes TOC-0 Series Detectors Gas Carbon Dioxide Standard Range 0-5000ppm A Order Code TOC-0A-CO Order Codes Gas Collector Cone For TOC-A-PHC Calibration Adaptor TOC-31-PHC Calibration Adaptor TOC0/ Series HSCO SOCO Code 50006701 Code 401101E Code 595701 SK 6TS TOC- Typical Cell Life TOC-A-PHC UK Design And Manufacture Fax: +44 (0) 161 484 345 REF T10-LPG-3R-V1.06