TECHNICAL DATA. Notes: For use with Trim Charts on Pages 227b - d

Similar documents
TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TECHNICAL DATA OBSOLETE

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

TECHNICAL DATA. 319a. January 27, 2012

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE

TECHNICAL DATA DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE

TECHNICAL DATA 1. SYSTEM DESCRIPTION 2. SYSTEM OPERATION 3. INSTALLATION. Page 1 of 5

Model: 400E-5M. Bermad Hydraulically Controlled Anti-Columning Deluge Valve, with Easylock Manual Reset. Installation Operation Maintenance

BERMAD Fire Protection

TECHNICAL DATA. Factory Mutual Approval is pending for the system as a whole.

Advanced Integrated Fire Protection Systems TOTALPAC 2. Owner's Operation and Maintenance Manual FIRECYCLE III. September 2009 FM-086G-0-5E

Standard response. elo sprinklers

Deluge System. Pneumatic Release. Deluge System. Pneumatic Release

TOTALPAC2 Integrated Fire Protection System

TECHNICAL DATA OBSOLETE

SECTION SPRINKLER SYSTEMS

SECTION DRY-PIPE SPRINKLER SYSTEMS

TotalPac X Single interlock SUREFIRE system

TECHNICAL DATA. model c-2

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

TotalPac X Firecycle III Preaction Double interlock system

STANDARD RESPONSE DRY PENDENT ELO SPRINKLERS TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS

TECHNICAL DATA 1. PRODUCT NAME 2. DISTRIBUTOR 3. INTRODUCTION 4. FIELD OF APPLICATION 5. TECHNICAL DATA. Page 1 of 6

esfr dry pendent sprinkler Vk502 (k14.0)

B. Standard-Pressure Standpipe Piping: Fire-suppression standpipe piping designed to operate at working pressure 175 psig (1200 kpa) maximum.

DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA TRIM DESCRIPTION DESCRIPTION VALVE OPERATION. 82 ASTM A 216 WBC.

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed.

Worldwide Contacts.

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

SPRINKLERS TABLE OF CONTENTS

SECTION PREACTION SPRINKLER SYSTEMS

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

HERZ Regulating valve 4002

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

standard response dry horizontal sidewall sprinklers

SECTION DRY-PIPE SPRINKLER SYSTEMS

DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package. General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP1300. Worldwide Contacts

Technical Data. Working Pressure Range 20 to 250 psi (1,4 to 17,2 bar)

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Self-contained system

Copyright 2016 AIA MasterSpec Full Length 09/16 PRODUCT MASTERSPEC LICENSED BY AVITRU, LLC TO VICTAULIC COMPANY.

esfr dry pendent sprinkler Vk501 (k14.0)

Deluge & Preac tion Systems

TECHNICAL DATA. Wet 26a. February 22, 2009

TotalPac 3 Firecyle III Deluge Remote controlled system

HERZ Differential Pressure Control Valve 4002

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

freedom residential horizontal sidewall lead free sprinkler VK4840 (k4.2)

Gas Station & C Store SECTION CWM Job No

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

TECHNICAL DATA. Viking Technical Data may be found on Pip Cap: Brass UNS-C31400 or UNS-C31600

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

standard response dry horizontal sidewall sprinklers

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

standard response dry horizontal sidewall sprinklers

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

standard response large orifice dry

OPEN SPRINKLER SYSTEM

TotalPac 3 Single interlock Firecyle III Preaction Self-contained system

STEAM TRAPS

micromatic standard response Upright sprinkler VK100 (K5.6)

Copyright 2016 AIA MasterSpec Full Length 09/16 PRODUCT MASTERSPEC LICENSED BY AVITRU, LLC TO VICTAULIC COMPANY.

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS

B. Related Sections: The following Sections contain requirements that relate to this Section.

WET-PIPE SPRINKLER SYSTEMS

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers

Annual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System

Public Comment No. 2-NFPA [ Section No ]

standard response/ quick response extended coverage

TECHNICAL DATA. Viking Technical Data may be found on. The Viking Corporation s Web site at.

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

quick response Sprinkler 105a October 25, 2010

PROFESSIONAL SUPPLIER

97105 Namur direct pneumatically actuated 3/2 and 5/2 spool valves

A. This section includes design and performance information for fire protection and suppression systems.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA

quick response sprinkler vk194 Sprinkler 104j January 1, 2011

Technical Data. Approvals The 1-1/2 in. to 8 in. (DN40 to DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

North Hanover Township School District North Hanover Township, New Jersey

Technical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

N2 BLAST Datasheet SUREFIRE double interlock c/w N 2 Blast Nitrogen generating system Self contained unit

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

SECTION SPRINKLER SYSTEMS

standard response Fusible Link Upright sprinkler VK204 (K8.0)

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

DRY VERTICAL SIDEWALL SPRINKLERS TECHNICAL DATA

Transcription:

Page 1 of 7 This Trim Chart is for use with the following Viking Trim Sets Valve Size Galvanized Trim Part No. Brass Trim Part No. 3 (DN80) 14631-1 14631-2 4 (DN100) 14632-1 14632-2 6 (DN150) 14633-1 14633-2 This Trim is for use with the following Release Module Trim Kits Release Type Galvanized* Brass** Figure 1 Electric 10830 10832 Pneumatic 10809 10811 Electric/ Pneumatic Pneumatic/ Pneumatic 12661-1 12661-2 12662-1 12662-2 * Standard Trim sets for Model E Deluge Valves consist of galvanized nipples and fittings. **Refer to Technical Data describing the Halar Coated Deluge Valve and the Viking Foam Systems Engineering Design Data book for applications where brass trim is recommended. Note: Nipple lengths for brass trim may vary from those shown on this Trim Chart. Notes: For use with Trim Charts on Pages 227b - d Note: When viewing this data page online, blue text represents hyperlinks and will open the appropriate data page when clicked. General Notes: Valve must be trimmed as shown. Any deviation from trim size or arrangement may affect the proper operation of the valve. All pipe, 3/4 (20 mm) and smaller, shall be galvanized steel except when other materials are specified in the Technical Data for the Halar Coated Deluge Valve or when other materials are specified in the Viking Foam Systems Engineering and Design Data book. When Model E Deluge Valves are used on pre-mixed Foam Systems, trim piping must be of black steel pipe with cast iron or malleable iron fittings unless otherwise specified in the Technical Data for the Halar Coated Deluge Valve or the Viking Foam Systems Engineering and Design Data book. Dimensions in parentheses are millimeter and may be approximations. Note 1: 1/2 (15 mm) NPT plugged outlet provided for connecting certain optional components and associated trim. Note 2: Release System connection. Viking Deluge and Flow Control Valves are compatible with hydraulic, pneumatic, and electric release systems. A Pneumatic Actuator is required on all Viking Deluge Valves and Flow Control Valves equipped with Pneumatic Release Systems. Note 3: Alarm Connections: Connect alarm line piping to 3/4 (20 mm) NPT outlet. When using a Water Motor Alarm, a strainer is required. 1/2 (15 mm) NPT outlet is for electric Alarm Pressure Switch. Note 4: Optional non-interruptible connection for Alarm Pressure Switch to activate electric alarm panel. Note: After the Deluge Valve trips, this location cannot be shut off. Alarms may operate until the outlet chamber of the deluge valve is de-pressurized below the set point of the Alarm Pressure Switch. Note 5: Viking Drain Check Valve is manufactured with a 0.067 (1.7 mm) orifice to allow alarm line to drain. Do not substitute. Check label for proper orientation. Note 6: Inlet side of PORV is connected to the top chamber of the deluge valve. Inlet of PORV should be facing up. Outlet goes to open drain. Replaces Form No. F_012194 Rev April 15, 2011 (Added P65 Warning.)

Page 2 of 7 Refer to page 227a for General Notes and Notes 1 through 6. Figure 2 3 Deluge Valve Trim

Page 3 of 7 Refer to page 227a for General Notes and Notes 1 through 6. Figure 3 4 Deluge Valve Trim

Page 4 of 7 Refer to page 227a for General Notes and Notes 1 through 6. Figure 4 6 Deluge Valve Trim

Page 5 of 7 Figure 5a: Installation Dimensions - 3 (DN80) Valve

Page 6 of 7 Figure 5b: Installation Dimensions - 4 (DN100) Valve

Page 7 of 7 Figure 5c: Installation Dimensions - 6 (DN150) Valve Replaces Form No. F_012194 Rev April 15, 2011 (Added P65 Warning.)