FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Similar documents
Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

395CAV Sizes 045 thru 155 Series H and J

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Upflow Furnace. Series 120 Input Capacities: 40,000 thru 135,000 Btuh

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Product Data. 58WAV WeatherMaker 8000 Energy-Efficient Deluxe Upflow Furnace. Series 150 and 160 Input Capacities: 45,000 thru 155,000 Btuh

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Deluxe Upflow Furnace

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE 3 -PASS PRIMARY HEAT EXCHANGERS FLOW -THROUGH SECONDARY HEAT EXCHANGERS MONOPORT INSHOT BURNERS

Product Data. 58GFA High-Efficiency Induced-Combustion Upflow Furnace. Heating Inputs: 65, ,000 Btuh

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE

Model PG9MAB MULTIPOISE CONDENSING GAS FURNACE SS-PG9MAB-01. Time Roman FEATURES. burners seldom, if ever, needs cleaning.

Product Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE

Product Data. 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 160

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

Product Data. 58MXA Deluxe 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace. Series 111 Input Capacities: 40,000 thru 120,000 Btuh

TECHNICAL SPECIFICATIONS

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 111 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. S QuieTecht noise reduction system. S SmartEvapt -Humidity control when using a Thermidistat Control

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

Cooling Capacity CFM in. w.c. (125 Pa)

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140, 150

Product Data. 58WAV Weathermaker 8000 High-Efficiency Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace Series 131 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. S HYBRID HEAT Dual Fuel System compatible S All models are chimney friendly when used with accessory vent kit

Product Data STANDARD FEATURES

Product Data. 340AAV 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Sizes 040 thru 140

Cooling Capacity CFM in. w.c. (125 Pa)

Gas Furnaces. Gas Furnaces. 2-Stage Variable-Speed. 2-Stage Multi-Speed Multipoise. Multipoise 80AFUE. 2-Stage Variable-Speed Multi-Speed Multipoise

Product Data. S ECM Blower Motor included S QuieTecht noise reduction system S SmartEvapt Humidity control when using a Thermidistatt Control

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

G6RC Series TECHNICAL SPECIFICATIONS

350MAV HIGHLY-EFFICIENT 4-WAY MULTIPOISE FIXED-CAPACITY DIRECT-VENT CONDENSING GAS FURNACE. Sizes 040 thru 140 Series D. Form No. PDS 350M.40.

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall

GAS FURNACES II 78% A.F.U.E. UPFLOW GAS FURNACES CRITERION

Product Data. 58MVP Deluxe 4-Way Multipoise Variable-Capacity Condensing Gas Furnace. Series 121 Input Capacities: 40,000 thru 120,000 Btuh

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

Rheem Classic Series Downflow/ Horizontal Gas Furnaces

Wt. Lbs Model Number (BTUH) Hz

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Ruud Acheiver Series Upflow Gas Furnaces

Cooling Capacity CFM range

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

TECHNICAL SPECIFICATIONS

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Cooling Capacity CFM in. w.c. (125 Pa)

GAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

GAS FURNACES CLASSIC 95% A.F.U.E. HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to kw] (All Models 90% A.F.U.E. or Above)

80% A.F.U.E. DOWNFLOW GAS FURNACES

G34M Bulletin #69/ August 2003

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

RG7D 1-Stage Heat Series

TECHNICAL SPECIFICATIONS

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

Product Data. 58MEC PERFORMANCE BOOST WAY MULTIPOISE STAGE CONDENSING GAS FURNACE Input Rates: 60,000 thru 120,000 Btuh

GAS FURNACES 90 PLUS WITH DUAL COMFORT CONTROL TWO-STAGE UPFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

TSTAT0201CW Recommended (sold separately)

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Product Data. 58STA/STX 4-WAY MULTIPOISE INDUCED-COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh THE CARRIER 58STA/STX GAS FURNACE

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

MERIT SERIES Downflow

RE9X Series Downflow, Upflow Electric Furnaces

Product Data. 58CMA Multipoise Oil Furnace. Series 120 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. 58CMA Multipoise Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

TSTAT0101SC Recommended (order separately)

8+* Bulletin No November 1997

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

58CTA/CTX PERFORMANCE 80 TWO --- STAGE WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES

Product Data. 58CTA/CTX PERFORMANCE 80 TWO-STAGE 4-WAY MULTIPOISE INDUCED-COMBUSTION FURNACE Input Capacities: 45,000 thru 155,000 Btuh

355MAV Sizes 040 thru 120 Series E

Product Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Comfort, Quality and Efficiency.

E2 Series. Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS. Features and Benefits

Product Data. 58CVA/CVX INFINITY 80 VARIABLE SPEED 4---WAY MULTIPOISE GAS FURNACE Input Capacities: 70,000 thru 155,000 Btuh Series 160

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

Product Data. 58RAV High-Efficiency Downflow/Horizontal Induced-Combustion Gas Furnace. 80% AFUE At Budget Price

Ruud Achiever Series Multi position Gas Furnaces

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

Product Data. S Unit may also be sidewall vented with an approved A S OVL units equipped with optional ECM 2.3 Variable

Transcription:

This document was created with FrameMaker 4.0.4 SIZES AVAILABLE: 024065 through 060150 EFFICIENCY: IGNITION: HEAT EXCHANGER: CONTROL BOARD: The GA1A Induced-Combustion Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE). Each furnace is equipped with a thermocouple-type continuous pilot which provides 100% shutoff of natural and propane gases. The patented 4-pass heat exchanger is made of aluminized steel and backed by a 10-year Limited Warranty. The GA1A Furnace has a control board that energizes the inducer and blower motors in sequence. The 24-v transformer is protected by a 3-amp fuse located on the front of the board for easy access. In addition, Electronic Air Cleaner (EAC) terminals are provided. FEATURES CABINET: Model GA1A The GA1A is assembled in a cabinet only 40 in. high. This simplifies installation in alcoves, attics, basements (ideal for short basement), closets, and utility rooms, especially with a taller high-efficiency cooling coil. The embossed galvanized steel with a clear coating surpasses our 200-hour high humidity test and provides superior rust and humidity protection. DRAFT SAFEGUARD: Our induced-combustion furnace has a patented draft safeguard system which stops furnace operation if the vent system becomes blocked or is not operating properly. An exclusive feature with our furnaces. INSTALLATION: The Model GA1A has many features that make installation easier: left or right gas and electrical connections, blower speed selector, matching coil sizes, thermostat low-voltage connections, EAC terminals, and many more. UPFLOW GAS FURNACE SS-GA1A-02

AIRFLOW 28 1 2 FLUE COLLAR 2 1 16 1 A D 13 16 2 1 16 1 19 OUTLET 13 16 7 8-IN. DIA HOLE POWER ENTRY 7 8-IN. DIA ACCESSORY 5 3 8 12 5 16 5 13 16 5 3 8 2 11 16 5 13 16 7 8-IN. DIA POWER ENTRY 1 1 2-IN. DIA R.H. GAS ENTRY 39 7 8 1 3 4-IN. DIA HOLE GAS ENTRY 1 2-IN. DIA HOLE THERMOSTAT WIRE ENTRY 2 3 8 2 3 8 7 8-IN. DIA ACCESSORY 1 2-IN. DIA THERMOSTAT WIRE ENTRY SIDE INLET SIDE INLET 14 1 2 1 3 4 11 16 24 5 16 AIR INLET 11 16 *Refer to the furnace Installation Instructions for proper venting procedures. 3 NOTE: 2 additional 7 8 In. Dia knockouts are located in the top plate. NOTES: E 11 16 Minimum return-air opening at furnace: 1. For 800 CFM 16-In. round or 14 1 2 x 12-In. rectangle. 2. For 1200 CFM 20-In. round or 14 1 2 x 19 1 2-In. rectangle. 3. For 1600 CFM 22-In. round or 14 1 2 x 23 1 4-In. rectangle. 4. For airflow requirements above 1800 CFM, use both side inlets, a combination of 1 side inlet and the bottom, or the bottom only. DIMENSIONS (In.) 1 23 1 4 SIDE RETURN DUCT LOCATION UNIT SIZE A D E VENT CONNECTION* SHIPPING WEIGHT 024065 14-3/16 12-9/16 11-11/16 4 124 036065 14-3/16 12-9/16 11-11/16 4 126 042086 17-1/2 15-7/8 15 4 140 048086 21 19-3/8 18-1/2 4 144 036105 17-1/2 15-7/8 15 4 150 048105 21 19-3/8 18-1/2 4 156 066105 24-1/2 22-7/8 22 4 172 048130 21 19-3/8 18-1/2 5 168 060130 24-1/2 22-7/8 22 5 182 060150 24-1/2 22-7/8 22 5 192 A88367 CLEARANCES (In.) UNIT SIZE 065 086 150 Sides Single-Wall Vent 1 0 Type B-1 Double-Wall Vent 0 0 Back 0 0 Top of Plenum 1 1 Vent Connector Single-Wall Vent 6 6 Type B-1 Double-Wall Vent 1 1 Front* Single-Wall Vent 6 6 Type B-1 Double-Wall Vent 3 3 Service 30 30 *The 3-in. front clearance is needed for combustion-air and ventilation-air entry. MEETS DOE RESIDENTIAL CONSERVATION SERVICES PROGRAM STANDARDS. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. 2

SPECIFICATIONS UNIT SIZE 024065 036065 042086 048086 RATINGS AND PERFORMANCE Input Btuh* 63,000 63,000 84,000 84,000 Capacity (Btuh) Nonweatherized ICS** 51,000 51,000 68,000 68,000 AFUE Nonweatherized ICS** 78.0 78.0 78.0 78.0 Certified Temperature Rise Range F 36 65 25 55 35 65 35 60 Certified External Static Pressure Heat/Cool 0.12/0.50 0.12/0.50 0.15/0.50 0.15/0.50 Airflow CFM Heating 830 1175 1150 1445 Cooling 950 1300 1335 1655 ELECTRICAL Unit Volts Hertz Phase 115 60 1 Operating Voltage Range Min Max 104 127 Maximum Unit Amps 7.1 8.7 9.0 10.4 Maximum Wire Length (Measured 1 Way) Ft 41 34 33 28 Minimum Wire Size 14 Maximum Fuse Size 15 Transformer (24v) 40VA External Control Heating 12VA Power Available Cooling 32VA Air Conditioning Blower Relay Standard CONTROLS Limit Control SPST Heating Blower Control Solid-State Time Operation Burners (Monoport) 3 3 4 4 Gas Connection Size 1/2-in. NPT GAS CONTROLS Gas Valve (Redundant) Honeywell Min Inlet Pressure (in. wc) 4.5 (Natural Gas) Max Inlet Pressure (in. wc) 13.6 (Natural Gas) Ignition Device Thermocouple-Type Continuous Pilot BLOWER DATA Direct-Drive Motor HP (PSC) 1/5 1/3 1/3 1/2 Motor Full Load Amps 4.9 6.5 6.8 8.2 RPM (Nominal) Speeds 1075 4 1075 4 1075 4 1075 4 Blower Wheel Diameter x Width (In.) 10 x 6 10 x 6 10 x 7 10 x 8 Filter Size (In.) Permanent Washable (Supplied) (1) 16 x 25 x 1 (1) 20 x 25 x 1 FACTORY-AUTHORIZED DEALER-INSTALLED ACCESSORIES Twinning Kit N/A KGATW0501STP Gas Conversion Kit Natural-to-Propane KGANP1801STP Gas Conversion Kit Propane-to-Natural KGAPN1301STP Side Filter Rack (With Washable Filter) (In.) KGAFR0106ALL (Filter Size 16 x 25 x 1) Return-Air Filter Cabinet (With Washable Filters) (In.) KGARP0101ALL (Filter Size 2 20 x 25 x 1) * Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 4% for each 1000 ft above sea level. Refer to National Fuel Gas Code Table F4. Capacity in accordance with U.S. Government DOE test procedures. Air delivery above 1800 CFM requires that both sides, or a combination of 1 side and bottom, or bottom only of the furnace be used for return air. A filter is required for each return-air supply. ** Isolated Combustion System DIMENSIONAL DRAWINGS OF OPTIONAL RETURN-AIR FILTER CABINET AND SIDE FILTER RACK 1 3 4 16 13 7 16 25 13 16 5 8 23 5 TYP 16 1 1 4 (TYP) 3 8 TABS 1 2 2 3 8 1 1 4 25 1 8 3 4 39 7 8 17 1 8 23 1 8 OPENING 14 1 2 OPENING 16 1 8 SIDE VIEW FRONT VIEW A93078 A80199 3

SPECIFICATIONS UNIT SIZE 036105 048105 066105 048130 060130 060150 RATINGS AND PERFORMANCE Input Btuh* 105,000 105,000 105,000 126,000 126,000 147,000 Capacity (Btuh) Nonweatherized ICS** 85,000 85,000 85,000 102,000 102,000 119,000 AFUE Nonweatherized ICS** 78.0 78.0 78.0 78.0 78.0 78.0 Certified Temperature Rise Range F 45 75 35 65 30 60 50 80 35 65 45 75 Certified External Static Pressure Heat/Cool 0.20/0.50 0.20/0.50 0.20/0.50 0.20/0.50 0.20/0.50 0.20/0.50 Airflow CFM Heating 1175 1415 1720 1385 1975 1670 Cooling 1210 1575 2210 1545 1980 1935 ELECTRICAL Unit Volts Hertz Phase 115 60 1 Operating Voltage Range Min Max 104 127 Maximum Unit Amps 8.0 10.1 14.4 10.1 13.3 13.7 Maximum Wire Length (Measured 1 Way) Ft 37 29 33 29 36 35 Minimum Wire Size 14 14 12 14 12 12 Maximum Fuse Size 15 15 20 15 20 20 Transformer (24v) 40VA External Control Heating 21VA Power Available Cooling 32VA Air Conditioning Blower Relay Standard CONTROLS Limit Control SPST Heating Blower Control Solid-State Time Operation Burners (Monoport) 5 5 5 6 6 7 Gas Connection Size 1/2-in. NPT GAS CONTROLS Gas Valve (Redundant) Honeywell Min Inlet Pressure (in. wc) 4.5 (Natural Gas) Max Inlet Pressure (in. wc) 13.6 (Natural Gas) Ignition Device Thermocouple-Type Continuous Pilot BLOWER DATA Direct-Drive Motor HP (PSC) 1/3 1/2 3/4 1/2 3/4 3/4 Motor Full Load Amps 5.8 7.9 12.2 7.9 11.1 11.5 RPM (Nominal) Speeds 1075 4 1075 4 1075 4 1075 4 1075 4 1075 4 Blower Wheel Diameter x Width (In.) 10 x 7 10 x 8 11 x 10 10 x 8 11 x 10 11 x 10 Filter Size (In.) Permanent Washable (Supplied) (1) 16 x 25 x 1 (1) 20 x 25 x 1 (1) 24 x 25 x 1 (1) 20 x 25 x 1 (1) 24 x 25 x 1 FACTORY-AUTHORIZED DEALER-INSTALLED ACCESSORIES Twinning Kit N/A KGATW0501STP Gas Conversion Kit (Natural-to-Propane) KGANP1801STP Gas Conversion Kit (Propane-to-Natural) KGAPN1301STP Side Filter Rack (With Washable Filter) (In.) KGAFR0106ALL (Filter Size 16 x 25 x 1) Return-Air Filter Cabinet (With Washable Filters) (In.) KGARP0101ALL (Filter Size 2 20 x 25 x 1) * Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 4% for each 1000 ft above sea level. Refer to National Fuel Gas Code Table F4. Capacity in accordance with U.S. Government DOE test procedures. Air delivery above 1800 CFM requires that both sides, or a combination of 1 side and bottom, or bottom only of the furnace be used for return air. A filter is required for each return-air supply. ** Isolated Combustion System 4

AIR DELIVERY CFM (WITH FILTER)* UNIT BLOWER EXTERNAL STATIC PRESSURE IN. WC SIZE MOTOR HP SPEED 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 High 1055 1030 995 950 900 830 750 024065 1/5 PSC Med-High 830 810 790 750 720 665 580 Med-Low 700 680 660 635 605 555 505 445 Low 600 575 550 520 475 450 400 340 High 1485 1430 1365 1300 1200 1140 1045 036065 1/3 PSC Med-High 1355 1305 1260 1200 1135 1055 960 Med-Low 1175 1170 1140 1110 1055 1005 950 860 Low 1025 1015 995 965 930 885 825 745 High 1585 1540 1470 1410 1335 1220 1110 980 042086 1/3 PSC Med-High 1355 1325 1280 1230 1175 1090 1015 910 Med-Low 1150 1125 1105 1085 1035 965 895 785 Low 960 950 935 910 880 815 715 580 High 1940 1875 1745 1730 1655 1545 1420 1315 048086 1/2 PSC Med-High 1665 1605 1575 1545 1490 1405 1300 1170 Med-Low 1460 1430 1395 1355 1325 1260 1165 1080 Low 1260 1240 1235 1215 1185 1115 1045 935 High 1490 1435 1370 1300 1210 1135 1020 880 036105 1/3 PSC Med-High 1375 1325 1265 1195 1125 1055 945 810 Med-Low 1205 1175 1130 1075 1025 925 830 675 Low 1045 1020 1000 960 905 820 700 565 High 1880 1815 1745 1690 1575 1500 1400 1265 048105 1/2 PSC Med-High 1660 1615 1570 1505 1435 1355 1260 1170 Med-Low 1455 1410 1375 1350 1290 1235 1145 985 Low 1265 1265 1240 1210 1180 1110 995 855 High 2475 2405 2330 2265 2210 2130 2040 1945 066105 3/4 PSC Med-High 2055 2025 2000 1965 1930 1865 1795 1720 Med-Low 1725 1720 1705 1685 1665 1630 1585 1525 Low 1500 1515 1510 1500 1480 1460 1415 1370 High 1850 1785 1710 1630 1545 1430 1320 1185 048130 1/2 PSC Med-High 1635 1595 1540 1480 1400 1300 1185 1065 Med-Low 1420 1385 1360 1295 1245 1165 1080 970 Low 1225 1200 1180 1145 1105 1055 990 870 High 2210 2130 2055 1980 1895 1795 1680 060130 3/4 PSC Med-High 2015 1975 1925 1880 1805 1735 1655 1555 Med-Low 1730 1710 1670 1635 1590 1535 1470 1385 Low 1525 1520 1495 1450 1410 1375 1315 1245 High 2220 2155 2105 2025 1935 1850 1765 1670 060150 3/4 PSC Med-High 1980 1920 1875 1815 1760 1700 1625 1530 Med-Low 1690 1670 1645 1615 1570 1520 1415 1385 Low 1445 1435 1425 1405 1365 1325 1280 1225 * Air delivery above 1800 CFM requires that both sides, or a combination of 1 side and bottom, or bottom only of the furnace to be used for return air. A filter is required for each return-air supply. Indicates unstable operating conditions. 5

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS 6 1993 RESCO P.O. Box 1667, Indianapolis, IN 46206 Catalog No. 92-32GA-1A2 PRINTED IN U.S.A. 8-93