Design and Evaluation of a Wildfire Sprinkler

Similar documents
Use of sprinklers and aqueous gel for structure protection from wildfire

MillworkTrends 10. What s Inside. 1 Joint Quality Standards 2 LEED. 3 Sustainability. 4 Diversification. 5 Finishing. 6 Indoor Air Quality

COMMUNITY WILDFIRE PROTECTION PLAN POWELL RIVER REGIONAL DISTRICT

CANADIAN SOCIETY OF LANDSCAPE ARCHITECTS DRAFT STRATEGIC PLAN 2018_20. Approved by the CSLA Members at the date AGM

PERFORMANCE OF CLT ASSEMBLIES IN FIRE

Scope of Work Urban Design Review Framework Monitoring Program Item #7.1

Town of Oakville Streetscape Strategy

CITY OF VAUGHAN EXTRACT FROM COUNCIL MEETING MINUTES OF NOVEMBER 15, 2016

Black Creek Oyster Bay Fire Service Administration Bylaw No. 293, 2014

Energy Technology and Innovations Canada (ETIC) March 2012

Update - Home Improvement

A Canadian Initiative to advance Conservation, Connections, Collaboration and Leadership for Parks and Protected Areas

SUSTAINABLE URBAN DEVELOPMENT AND COHESION POLICY EUROPEAN COMMISSION. Urban Policy within the framework of EU Cohesion Policy

Firefighting Group Water Systems. 1. Spray Nozzle 2. Fire Hose Box and Fire Hose Box 3. Barrel Fire Hydrant 4. Water Monitor

Fixed plant and mobile equipment fires on surface coal mines

Moving to the Cloud: The Potential of Hosted Central Station Services

PROGRAM. Innovations for the future; learning from the past. November 2-4, 2010 Hinton Training Centre, Hinton, Alberta, Canada

Fire and Gas Detection and Mitigation Systems

Local Growth Planning in North Central Green Line Communities

DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA

East to West, North to South: NFPA Resources for Fire Safety

UNDERSTANDING ELECTRICAL SAFETY RISKS

COURSE TITLE. 6 Day Off Campus Water-Based Fire Protection System Plans Review Fire Prevention: Technical O0137

Burned Dozer 230. I m just glad we get to do this the RLS process so others can learn something from it. Dozer Operator

Safety Message. How long do smoke alarms last? Smoke alarms need to be replaced every 10 years, whether battery-operated or hardwired (120V).

Standard Development Timeline

THE THOMPSON MODEL A STEAMER NEW UNIT ASSEMBLY INSTRUCTIONS

SAVE: Self-organizing Air VEnt System

July 2017 Safety Meeting Fire Extinguishers Part II

EMTA regularly contributes to the European Commission consultation exercises, and takes opportunities to voice its concerns to European Institutions

Frequently Asked Questions

CITY COUNCIL AGENDA REPORT

THE SDG INDICATOR FRAMEWORK IN AFRICA

Appendix 3 Fire Suppression Systems For AASA sanctioned events V0.1

Protected Areas: Context for Planning and Management Parks Canada Perspective

BAYFRONT INDUSTRIAL AREA RENEWAL STRATEGY

Advisory Brief to Prince George City Council On the Matter of Bylaw 8727, 2013, Fire Protection and Emergency Response Bylaw

Township of North Kawartha. Report to Council Emergency Services Department

Second Revision No. 1-NFPA [ Section No. 2.2 ] Submitter Information Verification. Committee Statement

WAIPAROUS FIRESMART NEWS

ENHANCED ODOR-DETECTION SYSTEMS. A Patented System Developed by K-9 Search on Site (K-9 SOS)

SECTION : FIRE PROTECTION SYSTEMS

Optical Fibres ELEC8350

June 2013 Safety Meeting Fire Extinguishers Part II

HYDROGEN EMERGENCY RESPONSE TRAINING FOR FIRST RESPONDERS

Modelling Appliance Loads in Multi-Unit Residential Buildings

Repair & RemodelingTrends. Repair & Remodeling in a Turbulent Economy. What s Inside. Repair & Remodeling Demand Fundamentals

BCGEU JOB DESCRIPTION MINISTRY OF FORESTS

Storage Protection Using Horizontal Barriers and Large K-Factor, Extended Coverage In-Rack Sprinklers

The Pimachiowin Aki Management Plan: A case-study of collaborative planning in Canada s boreal forest.

Scope of Services. River Oaks Boulevard (SH 183) Corridor Master Plan

Inspiring Technovation

Course Outline Cover Page

Fire Sprinklers Working Group Final Report

A Building Manager s Guide to Maintaining Fire Code Compliance

Suction cups VAS/VASB

DGE 2 EUROPEAN UNION. Brussels, 20 September 2017 (OR. en) 2016/0287 (COD) PE-CONS 28/17 TELECOM 158 FC 54 CODEC 1008

Role of the fire service on the emergency management and planning team

Chubb Monitoring Solutions

National Forests in Mississippi. De Soto Ranger District. Acadian Wildland Fire. Firefighter Burn Incident - May 2, 2011

Cartridge Heater Solutions

West Chester Fire Dept. Fire Code Maintenance Handbook. Fire Prevention Saves Lives and Property

COUNTY OF BERGEN DEPARTMENT OF PUBLIC SAFETY LAW AND PUBLIC SAFETY INSTITUTE POLICE, FIRE & EMS ACADEMIES 281 Campgaw Road Mahwah, N.J.

DIVISION 21 FIRE SUPPRESSION FIRE SUPRESSION

Implementing sustainable water strategy through development industry engagement

ALBERTA FOREST PROTECTION THERMAL INFRARED PROGRAM

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

Monitoring for Ecological Integrity and State of the Parks Reporting

CENTRAL CALAVERAS FIRE AND RESCUE TRAINING DIVISION CAREER TRAINING AND DEVELOPMENT FIREFIGHTER II STANDARDS

Iron Owl Rooftop Sprinklers

quarters Building Our Cultural Quarters Together

SECURITY BLANKET Foam Fire Protection Products

Downtown Whitby Action Plan

A Better Way to Support Wildland Fire Suppression

IRO Reliability Coordinator Real-time Reliability Monitoring and Analysis Capabilities

GLOBAL ENCLOSURE STANDARDS WITHIN THE ELECTRICAL INDUSTRY

Required Materials For complete material(s) information, refer to

Prereq: FOD 131 or Instructor Permission

master plan of highways bus rapid transit amendment

Technical Paper. Functional Safety Update IEC Edition 2 Standards Update

The Role of the Landscape Contractor to Conserve Water

HALON FLIGHTLINE EXTINGUISHER EVALUATION: DATA SUPPORTING STANDARD DEVELOPMENT [INCLUDES NOVEMBER 2007 ADDENDUM]

The Monaco Patio. Please read and save these instructions

New Certification and Training Structure

EVAP Project BACKGROUND EVAP UNIT

Sprinkler Fitter Transition Plan

The Corporation of the Town of Milton

TRCA Field Staking Protocol December 2016

SAGINAW FIRE DEPARTMENT SAFER

Summary. firefighter training in Since that time the firefighter had attended semi-annual

INCIPIENT FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

Fin the revolution in standing work

The Corporation of the District of North Cowichan Fire Protection Bylaw Bylaw 3340

CITY OF FARGO PARKING RAMP SITE EVALUATION

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

The 2012 Fire Suppression Rating Schedule (FSRS)

Revised March 2015 Fire Alarm Systems Verification. Schedule I(A) Services. *Manditory Site visit required*

Capital Projects Group Fire Extinguishers Specification

CAMDEN COUNTY FIRE COORDINATOR

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

Transcription:

Design and Evaluation of a Wildfire Sprinkler September 2017 Roy Campbell Technical report no. 53 Wildfire Operational Research Group http://wildfire.fpinnovations.ca/ fpinnovations.ca

FPInnovations is a not-for-profit worldleading R&D institute that specializes in the creation of scientific solutions in support of the Canadian forest sector s global competitiveness and responds to the priority needs of its industry members and government partners. It is ideally positioned to perform research, innovate, and deliver state-of-the-art solutions for every area of the sector s value chain, from forest operations to consumer and industrial products. Its R&D laboratories are located in Québec, Montréal, and Vancouver, and it has technology transfer offices across Canada. For more information about FPInnovations, visit: www.fpinnovations.ca. Follow us on: 301012308: Design and evaluation of a new wildfire sprinkler Technical report no. 53 Abstract The goal of the project was to develop a new wildland fire sprinkler capable of stream-height adjustment. A Fire Cobra prototype was built base on a design from a team of University of Alberta Mechanical Engineering students. Through field tests, the prototype was inferior and would require additional modifications to become functional. A modified rainbird sprinkler was tested and it produced 8 m semi-vertical stream. The conclusions reached from the testing included that is possible to use an attachment kit to modify an existing kit sprinkler and farther engineering would be required to provide for a more streamlined kit design capable of sustaining the desired pressure ranges. Over the course of the project a new industrial sprinkler called the FireBozz was identified in the market place. The legs of FireBozz can be adjusted to change the stream angle height. Acknowledgements This project was financially supported by Alberta Agriculture and Forestry. The author thanks MYAC Consulting Inc. and the University of Alberta Mechanical Engineering students involved in this project. Reviewer Ray Ault Researcher Wilderness Fire Management Inc. raymond.ault@gmail.com Contact Roy Campbell, Researcher Wildfire Operations Research 403-851-0157 Roy.Campbell@fpinnovations.ca 2017 FPInnovations. All rights reserved. Unauthorized copying or redistribution prohibited. Disclosure for Commercial Application: If you require assistance to implement these research findings, please contact FPInnovations at info@fpinnovations.ca.

Table of contents 1. INTRODUCTION... 4 2. METHODS... 4 Product investigation... 4 Project planning... 5 Prototype design... 6 Prototype construction... 6 Prototype testing... 7 3. RESULTS... 7 Product investigation... 7 Prototype construction... 8 Prototype testing and evaluation... 9 Hinton test... 10 Fort Providence test... 10 Test of a modified rainbird... 10 4. DISCUSSION... 11 List of figures Figure 1. Typical sprinkler kit.... 4 Figure 2. Sprinkler trailer.... 5 Figure 3. Improvised sprinkler mounting.... 5 Figure 4. Prototype design of the Fire Cobra sprinkler.... 6 Figure 5. FireBozz sprinkler.... 8 Figure 6. Fire Cobra prototype complete with height adjustment.... 8 Figure 7. Location of the rotation spring on the Fire Cobra prototype.... 9 Figure 8. Modified rainbird kit.... 11 FPInnovations Page 3

1. INTRODUCTION Sprinkler systems are commonly used in wildland firefighting to wet fuels, protect structures, and re-enforce fireguards ahead of an on-coming fire. The type of sprinklers most commonly used in wildfire scenarios are those that can be purchased at a local hardware store. Typically, sprinklers are mounted at ground level, or they can be elevated using various attachments and improvised methods. Although off-the-shelf sprinklers meet many deployment objectives, the need to mount sprinklers to attain the desired stream height and coverage can take considerable time and effort. The new wildfire sprinkler project was proposed by Alberta Agriculture and Forestry and endorsed by FPInnovations Wildfire Advisory Committee in 2010. The original goal of the project was to develop a new wildland fire sprinkler capable of stream-height adjustment. The project s objectives included creating a prototype design, construct, test, and evaluate the prototype. Several challenges were encountered over the course of this project, which caused delays, altered the project s direction, and affected the project s outcomes. This report presents the project s methods and results, and discusses what was learned. 2. METHODS Product investigation The first step was to confirm which sprinkler models and applications were currently being used in wildfire suppression. An internet search and agency discussions indicated the most common sprinklers used in wildfire applications were over-the-counter lawn-care sprinklers. Our research also indicated that many firefighting agencies had developed their own sprinkler kits (Figure 1), and in some instances had developed sprinkler trailers in order to organize equipment and facilitate quick deployment (Figure 2). Many of these sprinkler systems were typically used for protecting structures and to reinforce wildfire or prescribed-fire control lines. In most cases these sprinklers lacked vertical height adjustment and relied on additional work and or improvisation to adjust stream height (Figure 3). Figure 1. Typical sprinkler kit. FPInnovations Page 4

Figure 2. Sprinkler trailer. Figure 3. Improvised sprinkler mounting. Project planning An FPInnovations project plan 1 was developed in March 2011 to identify project objectives, methods, safety concerns, timelines, and deliverables. Additional project planning was also completed by some mechanical engineering students, as part of the prototype design phase. As the project progressed, original plans were adjusted to meet the challenges encountered. 1 http://wildfire.fpinnovations.ca/10/wildfiresprinklerdesignprojectplan.pdf FPInnovations Page 5

Prototype design Design work was initiated through a MEC E 460 project proposal from the University of Alberta s Mechanical Engineering Department 2. In September 2011, a student design team called Alberta Genuine Design was assigned to the project, and in March 2012 the design team submitted three design concepts based on both the project criteria established within the FPInnovations project plan, and criteria layed out in the MEC E project proposal. Included within this criteria, was the specific need to design a sprinkler capable of height adjustment. From the three proposed designs, the Fire Cobra (Figure 4) was identified for continued development, and in April 2012 the design team submitted its final report for the Fire Cobra design, complete with calculations and detailed drawings. 3 Figure 4. Prototype design of the Fire Cobra sprinkler. Prototype construction Originally, prototype construction was planned as part of the students overall MEC E 460 project. Due to time constraints the team was able to complete only the design phase. Prototype construction focus then shifted to partnering with the manufacturing industry, and several attempts were made to generate interest among sprinkler manufacturers. However, due to low interest, a decision was made to construct the prototype using a local machine shop in 2015. 2 http://wildfire.fpinnovations.ca/10/mec%20e%20460_application_2012_sprinkler_system.pdf 3 http://wildfire.fpinnovations.ca/10/mec%20e%20460%20-%20phase%203.pdf FPInnovations Page 6

Prototype testing Prototype testing was originally planned as an exercise that would be integrated with on-going FPInnovations project work at the Canadian Boreal Community FireSmart Project site in Fort Providence, Northwest Territories. Additional testing options also included hazard-reduction and prescribed-burn operations in Alberta. Testing criteria included: stream height and horizontal cast measurements, and prototype comparison with a typical sprinkler from an agency sprinkler kit. Testing of the Fire Cobra prototype sprinkler was to occur in two stages: 1. Functionality testing, including attaching the prototype to a water source and observing the performance of the Fire Cobra under a range of pressures. 2. Performance testing, pending initial results of the functionality testing, and included: a. Establishing a functional pressure range. b. Measuring stream cast (height and distance) at pre-determined angles (30, 50, and 70 degrees). c. Measuring the stream-cast footprint at pre-determined angles (diameter). d. Comparing the prototype to a rainbird sprinkler (repeat of above measurements using a typical sprinkler and kit). Equipment requirements for these tests included: One Fire Cobra prototype. One water-pressure gauge. One Mark-3 pump / kit. Two lengths of 1.5-inch fire hose (approximately 30 m total). 60 m of 5/8-inch garden hose. One 5/8-inch adapter. The possibility of constructing additional prototype sprinklers to enable full kit comparisons was discussed, but the decision was deferred to such time as the prototype proved functional. 3. RESULTS Product investigation Initial investigations reaffirmed the potential for a new, innovative sprinkler, i.e., typical sprinklers found in sprinkler kits did not have height-adjustment capability. Over the course of the project a new industrial sprinkler called the FireBozz was identified in the market place (Figure 5). The legs of the FireBozz can be adjusted to change the stream angle height. FPInnovations Page 7

Figure 5. FireBozz sprinkler. Prototype construction Construction of the Fire Cobra prototype, although delayed, was completed in 2015 (Figure 6). Spray height is adjusted by moving the upper black rubber hose down the curved metal hose holder, thus changing the spray angle. Materials used in its construction were mostly heavy-gauge steel, as opposed to the proposed design materials such as aluminium, to keep manufacturing costs low through the prototype testing phase. Figure 6. Fire Cobra prototype complete with height adjustment. FPInnovations Page 8

During construction of the prototype the machine shop identified that the heavy-gauge rotation spring (Figure 7) could impede sprinkler functionality. Based on this feedback, several lighter gauge springs were purchased for testing. Rotation spring Figure 7. Location of the rotation spring on the Fire Cobra prototype. Prototype testing and evaluation Two functionality tests of the Fire Cobra prototype were completed. One took place near Hinton, Alberta in May 2016 and another took place near Fort Providence, Northwest Territories in June 2016. The Hinton test served as the initial test using a low-pressure municipal water source. This test was performed to establish a baseline for future testing at higher pressures. The Fort Providence test was conducted at higher water pressures using a local dugout and a Mark-3 pump and hose lay. The equipment used in these tests included: One Fire Cobra prototype (Hinton and Fort Providence). 60 m of 5/8-inch garden hose (Hinton). One 5/8-inch adapter (Hinton). One water-pressure gauge (Hinton and Fort Providence). One Mark-3 pump / kit (Fort Providence). Two hose lengths (approximately 30 m) of 1.5-inch fire hose (Fort Providence). FPInnovations Page 9

Hinton test The sprinkler prototype was attached to a residential outlet using a regular garden hose. The system registered a pressure of ~45 psi at the sprinkler head, which was insuffcient pressure to rotate the sprinkler. The water cast produced a light focused stream with very little spray, and the pressure was insufficient to create sufficient sideway force for sprinkler rotation. The stream carried ~8.5 m with the nozzle adjusted ~25 degrees upwards. The test was repeated using a light rotation spring with no difference in results. Our conclusion was that the prototype would not function properly under this pressure. Fort Providence test The sprinkler prototype was attached to 30 m of 1.5-inch hose using a 5/8-inch adapter and a length of 5/8-inch sprinkler hose. A Mark-3 pump generated ~85 to ~105 psi at the sprinkler head; however, no rotation was observed within this pressure range. The water stream from the sprinkler carried ~14 m. Our conclusion was that the prototype design was inferior and would require additional design modifications to become functional. Test of a modified rainbird Given the issues encountered with the Fire Cobra prototype, a simple trial was completed using improvised parts attached to a standard rainbird sprinkler (Figure 8). This was not part of the original project plan; however, an opportunity was realized and pursued. A modified rainbird kit was assembled using a ½-inch rubber hose, a nozzle, and an aluminum bracket. The hose was attached to the rainbird s rear sprinkler port and the spray height angle was adjusted using a nut-and-bolt assembly located at the top of the bracket. Given the original rainbird sprinkler had not been altered, with the exception of the added kit, water streamed through the rainbird nozzle and the kit nozzle. A rainbird sprinkler and modified rainbird kit were then attached to the Mark-3 pump and hose setup, as described above for the Fort Providence test. The horizontal stream from the rainbird nozzle was ~12 m and the semi-vertical stream from the kit nozzle was ~8 m. An additional measurement was also taken with the vertical nozzle adjusted to the horizontal position, which produced a similar stream distance in both the original rainbird nozzle and the adjusted kit nozzle. During testing the improvised kit hose separated under higher pressures. The conclusions reached from this testing included: 1. It is possible to use an attachment kit to modify an existing kit sprinkler. 2. Engineering would be required to provide for a more streamlined kit design capable of sustaining the desired pressure ranges. FPInnovations Page 10

Figure 8. Modified rainbird kit. 4. DISCUSSION The Fire Cobra sprinkler design achieved the project goal in terms of height adjustability; however, the engineered prototype clearly required additional design work and testing to achieve functionality, including: 1. An engineered solution to prototype rotation is needed. The parts related to rotation were not addressed in the original design, and although an attempt was made by the machine shop to address rotation during prototype construction, the parts added and their tolerances were loose and rotation did not function properly. Rotation arm balancing would also be required as part of the solution to the rotation issue. 2. A design for the rotation spring is required. Spring force was not defined in the design and the original spring used in the Fire Cobra was considered too stiff. Although multiple smaller springs were obtained by the machine shop, they also proved too stiff to facilitate proper rotation. 3. The materials used in construction of the prototype may have contributed to prototype s failure, i.e., in terms of weight. In testing the Fire Cobra, a simpler concept using an attachable kit was also explored. This concept could provide a more versatile and cost-effective solution. However, this design requires additional thought and engineering, e.g., regarding the use of a sacrificial stream to power the rotation, which may reduce pressure, stream distance, and overall coverage. Another concept, which was not explored during project testing, is to provide height adjustment through the placement of a swivel joint between the sprinkler stake and the rainbird. This would also require additional thought and engineering. FPInnovations Page 11

The FireBozz sprinkler (Figure 5) does provide for height adjustment and is now commercially available. However, the rainbird and FireBozz sprinklers are quite different in size, weight, and cost. Although there is some overlap in how and where they are applied, it is suspected that each may have their own application niche. This too has not been fully explored; however, additional information is being generated from an FPInnovations research project involving the FireBozz, which may be helpful once research is complete. Based on the test results obtained in this project, and considering the need for additional investment in the Fire Cobra, the kit concepts generated during testing, and the existence of an industrial height-adjustable sprinkler, we are recommending bringing this project to conclusion. Should there be interest in pursuing this work, it is recommended that a new project be formulated based on renewed objectives and the findings presented here. FPInnovations Page 12

Head Office Pointe-Claire 570, Saint-Jean Blvd. Pointe-Claire, QC Canada H9R 3J9 T 514 630-4100 Vancouver 2665 East Mall Vancouver, BC. Canada V6T 1Z4 T 604 224-3221 Québec 319, rue Franquet Québec, QC Canada G1P 4R4 T 418 659-2647