Firefighting Group Water Systems. 1. Spray Nozzle 2. Fire Hose Box and Fire Hose Box 3. Barrel Fire Hydrant 4. Water Monitor
|
|
- Coleen Howard
- 5 years ago
- Views:
Transcription
1
2 Firefighting Group Water Systems 1. Spray Nozzle 2. Fire Hose Box and Fire Hose Box 3. Barrel Fire Hydrant 4. Water
3 Flat Spray Nozzle Model No.7010 Size ½ to 1 NPT Flat Type The GPE tank cooling water spray nozzles are designed to produce wide angle flat spraying flows and are available in a wide range of bore sizes and materials. The 7000 series is ideally suited to the protection of storage tank shells and roofs and is widely used in process plant to protect equipment and structural members from the damaging effect of heat. The nozzle is also particularly effective in applications where a water screen is required to isolate a risk and to prevent the spread of fire or to protect escaping personnel from radiated heat. Minimizing the flow rate of spray nozzle: The minimum flow rate of each spray nozzle with any K-factor is determined with following equation: Flow (LPM) = K-Factor P =Minimum pressure = 1 BARG. (Recommended) The range of pressure = 1 to 6 BARG. 90
4 Directional Spray Nozzle Model No.7020 Medium Velocity Water spray Size ½ to1 NPT The Model 7020 spray nozzles are open (non-automatic) directional spray nozzles and are designed for use in water spray fixed systems for fire protection applications. They are external deflector type nozzles that discharge a uniformly filled cone of medium velocity water droplets. The 7020 Nozzles are effective in covering exposed vertical, horizontal, curved, and irregular shaped surfaces in a cooling spray to prevent excessive absorption of heat from an external fire and possible structural damage or spread of fire to the protected equipment. The Type 7020 nozzles are available in a wide variety of orifice sizes and spray angles (included angle of discharge) to provide versatility in system design. These spray nozzles are using in off-shore platforms, Refineries, Power Station, LPG & LNG Plants, Spherical Tanks Minimum Flow Rate of Spray Nozzle: The minimum flow rate of each spray nozzle with different K-Factor determined with following equation: Flow (Lpm) = K-Factor P =Minimum pressure = 1 Barg. (Recommended) The range of pressure = 1.0 to 5.0 Barg. Recommended Pressure 1.5 to 3.5 Barg. A= Spray Angle D =Spray Distance from wall side Theoretical Coverage Distance = (2 D) tan(a) B=Wet acoverage Distance = 0.8(2 D) tan(a) 91
5 Fire Hose Box and Hose Reel Model No Water Proof Self-Standing / Wall Mounted Indoor / Outdoor GPE fire hose/hose reel box used to store fire hose and equipment for outdoor use in industrial applications. The Hose Storage Cabinet, constructed of carbon steel or coat galvanized metal with two coats red baked enamel. Stainless steel piano hinges with chrome plated door latches mm Carbon Steel or galvanized steel sheet. Empty shelves 13 wide with 3 / 4 lip 2 slope on roof Rain trough over doors Door reinforcement at front, top and bottom Doors overlap tub at hinge side Piano hinge on both doors Door lock (R.H. door only) Chrome plated handle with 2 point catch Louvers on each end under bottom shelf (optional-please specify) Inside lips (front side) 3 at top 1 ½ at bottom 1 at sides and bottom Two coats red baked enamel Ral 3020 To Specify: Free Standing/without legs Wall Mounted (with rear lugs top & bottom) Concrete Base Mounted (with grouting lugs at bottom) Support Mounted - legs packed separately 92
6 Wet Barrel Fire Hydrant Model 7400 Group The fire hydrants provided under this category are post type, Wet barrel, class A fire hydrants. Wet Barrel hydrants are available in different model as below: Hose Connection Pumper Connection Model No Size (in) Type Size (in) Type ½ Thread 4 Thread _ ½ Thread 5 Thread _ ½ Thread 4 Flanged _ ½ Thread 5 Flanged _ ½ Thread 4 Flanged With Single Arm ½ Thread 5 Flanged With Double Arm ½ Flanged 4 Thread _ ½ Flanged 5 Thread _ ½ Flanged 4 Flanged _ ½ Flanged 5 Flanged _ ½ Flanged 4 Flanged With Single Arm ½ Flanged 5 Flanged With Double Arm fire hydrant main valve is a Butterfly Valve type. The hydrant main valve and operating parts including valve seat, valve seat insert are of bronze. Hydrant body consists of two 2½ inch hose nozzle and pumper nozzle in three sizes 4, 4½, 5 inches in tow Flanged and Threaded Types. These types of hydrants are available with water monitors. 93
7 Dry Barrel Fire Hydrant Model 7500 Group The Fire hydrants provided under this category are post type. Dry barrel hydrants are available in different models as below: Features and Benefits: s fire hydrant main valve is a manual type. The hydrant main valve and operating parts including valve seat, valve seat insert are of bronze. Hydrant body consists of two 2½ inch hose nozzle and 4½ inch pumper nozzle, all with NFPA No. 194 standard Fire Hose Coupling Screw Threads. Hose Connection Pumper Connection Model No Size Size Type Type _ (in) (in) ½ Thread 4 Thread _ ½ Thread 5 Thread _ ½ Thread 4 Flanged _ ½ Thread 5 Flanged _ ½ Thread 4 Flanged With Single Arm ½ Thread 5 Flanged With Double Arm ½ Flanged 4 Thread _ ½ Flanged 5 Thread _ ½ Flanged 4 Flanged _ ½ Flanged 5 Flanged _ ½ Flanged 4 Flanged With Single Arm ½ Flanged 5 Flanged With Double Arm 94
8 Water Model No Sizes 3 or 4 2 No. Swivel Joint Fixed Type Manual Operating The handle monitor comes with both a left/right and an up/down lock handle. To disengage lock(s), turn handle(s) counterclockwise. Move the tiller handle to direct the stream to the desired position. Turn lock handle(s) clockwise to engage lock. Corrosion resistant with brass construction; Unique configuration; Flow up to 1250 gpm; Compact -3 or 4 150# ANSI flange; Vertical movement 90 degrees above horizontal to 45 degrees below; Full, continuous 360 degree rotation; Rugged, stainless steel lock hardware;grease fittings for easy lubrication;durable Electro Statics finish. 95
CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM
SECTION 21 0000 AUTOMATIC FIRE SPRINKLER SYSTEM PART 1 GENERAL 1.1 QUALITY ASSURANCE A. Codes and Standards: 1. FBC (Florida Building Code 2015) 2. FBC (Florida Fire Code 2015) 3. NFPA #13R (Standard for
More informationDIVISION 21 FIRE SUPPRESSION FIRE SUPRESSION
DIVISION 21 FIRE SUPPRESSION 21 00 00 FIRE SUPRESSION 21 01 00 Operation and Maintenance of Fire Suppression 21 01 10 Operation and Maintenance of Water Based Fire Suppression Systems 21 01 20 Operation
More informationF Cleaning In Place. industries and NEW markets. challenges. Meeting the. of new WELCOME TO DELAVAN
F Cleaning In Place Meeting the challenges of new WELCOME TO DELAVAN industries and NEW markets SECTION INDEX TYPICAL SPRAY PATTERN Various types of fixed and rotating spray heads are specified in this
More informationGas Station & C Store SECTION CWM Job No
SECTION 21 1300 - PART 1 - GENERAL 1.1 WORK INCLUDED A. Provide labor, materials, equipment and services to perform operations required for the complete installation and related Work as required in Contract
More informationSECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section
PART 1 - GENERAL 1.00 GENERAL PROVISIONS A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section 1.01 DESCRIPTION OF WORK A. Work Included: Provide
More informationAutomatic Sprinklers
CONCEALED PENDENT SPRINKLERS MODEL: BZ007 / BZ008 STANDARD SPRAY, STANDARD / QUICK RESPONSE, 5 / 3 mm BULB TYPE, K5.6, 1/2" CONNECTING THREAD GENERAL DESCRIPTION The BZ007/BZ008 Standard/Quick Response
More informationPlumbing Solutions for Agriculture and Irrigation Applications
Plumbing Solutions for Agriculture and Irrigation Applications Watts.com Watts.com ANKA Series The ANKA Series farm-tough line includes high quality glass-filled nylon pipe fittings, quick connect fittings,
More informationWATER POWERED OSCILLATING MONITOR
WATER POWERED OSCILLATING MONITOR HD FIRE PROTECT TECHNICAL DATA MODEL VAJRA 331-S FLOW With 40U 500 or 750 or 1000 GPM. MINIMUM & MAXIMUM OPRATING PRESSURE FACTORY HYDROTESTED SWIVEL JOINT With HF40U
More informationModel F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers
Bulletin 060 Rev. A Bulletin 060 Rev. A Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers Features 1. Available in the following configurations: Pendent with standard escutcheon
More informationSECTION FIRE PROTECTION
SECTION 15300 - FIRE PROTECTION PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR
More informationmore powerful than hand-held alternatives so they do a better job of cleaning and removing deposits.
No-Entry Systems Safe and Effective Vessel Cleaning Powerful Tools Allow You to Put Safety First Safer and more effective - it s the StoneAge winning combination. We make several tools for vessel and tank
More informationTN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.
TN-25 Tunnel Fire Protection System Safer. Smarter. Tyco. Expert Fire Protection for Tunnels Tyco provides a complete fire protection solution to protect the infrastructure of tunnels. Whether it is rail,
More informationRAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description Pendent Sprinklers (TY2235)
More informationRAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description The TYCO RAPID RESPONSE Series LFII
More informationRAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description Pendent Sprinklers (TY2235)
More informationC. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.
SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.
More informationesfr dry pendent sprinkler Vk502 (k14.0)
Page 1 of 11 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Dry Pendent Sprinkler VK502 is a fast response fusible element type sprinkler designed for use in storage areas subject to freezing
More informationPage 1 of 8 DECEMBER 2018 TFP408. Worldwide Contacts.
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 6.9 K-factor, Pendent/Recessed Pendent/Concealed, NFPA 13 Optimized Wet Pipe Systems General Description The TYCO
More informationMODEL: FA003U FA004U FA005P FA006P STANDARD SPRAY, STANDARD QUICK RESPONSE, 5 3 mm BULB TYPE, K5.6, 1/2" CONNECTING THREAD
UPRIGHT SPRINKLERS AND PENDENT SPRINKLERS MODEL: FA003U FA004U FA005P FA006P STANDARD SPRAY, STANDARD QUICK RESPONSE, 5 3 mm BULB TYPE, K5.6, 1/2" CONNECTING THREAD GENERAL DESCRIPTION The FA003U/FA004U
More informationRAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description The TYCO RAPID RESPONSE Series LFII
More informationRAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems General Description The TYCO RAPID RESPONSE Series
More informationINSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA
Page 1 of 8 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Standard Coverage/Extended Coverage Flush Pendent Sprinklers are small, flush, solder link and lever sprinklers made with tamper-resistant
More informationTECHNICAL DATA OBSOLETE
June 1, 2008 Foam 138a 1. DESCRIPTION Chemguard Water Powered Oscillating Monitors are designed to automatically discharge over a specifi c design area upon system activation. These are suitable for use
More informationRAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description The TYCO RAPID RESPONSE
More informationFREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK498 (K5.8) TECHNICAL DATA
Page 1 of 5 1. DESCRIPTION Viking Freedom Residential Concealed Pendent VK498 is a small thermosensitive, glass-bulb residential sprinkler designed for installation on concealed pipe systems where the
More informationproven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential 4.9 K-factor Pendent Sprinkler Wet Pipe and Dry Pipe Systems General Description TYCO RAPID RESPONSE Series Recessed Pendent
More informationAutomatic Sprinklers
UPRIGHT SPRINKLERS AND PENDENT SPRINKLERS MODEL: BZ003 / BZ004 / BZ005 / BZ006 STANDARD SPRAY, STANDARD / QUICK RESPONSE, 5 / 3 mm BULB TYPE, K5.6, 1/2" CONNECTING THREAD GENERAL DESCRIPTION The BZ003/BZ004
More informationESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA
Page 1 of 7 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Pendent Sprinkler VK510 incorporates the capability to suppress specific high-challenge fires. The addition of a larger K-Factor
More informationS19314 Series. Combination Drench Shower and Halo Eyewash or Eye/Face Wash. Recommended Option:
Halo and SpinTec Deliver the Most Effective Shower and Eye/Face Washdown Coverage and Spray Pattern Exceeds American National Standard Z358.1 Specifications Exceeds European EN 15154-1 & EN 15154-2 Industry's
More informationS19314 Series. Combination Drench Shower and Halo Eyewash or Eye/Face Wash. Recommended Option:
Halo and SpinTec Deliver the Most Effective Shower and Eye/Face Washdown Coverage and Spray Pattern Exceeds American National Standard Z358.1 Specifications Exceeds European EN 15154-1 & EN 15154-2 Industry's
More informationModel F1 Residential Sprinklers for Design Density of.10 gpm/ft 2
Model F1 Res s engineered for the lowest flows to meet the minimum design density of.05 gpm/ft 2 Types: 1. F1 Res 49 Pendent 2. F1 Res 49 Recessed Pendent/F1 3. F1 Res 49 Recessed Pendent/FP 4. F1 Res
More informationWRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 4.4 K-factor Horizontal Sidewall Wet Pipe Systems General Description LFII Residential Horizontal Sidewall Sprinklers
More informationSECTION FIRE-SUPPRESSION STANDPIPES
PART 1 - GENERAL 1.1 DESCRIPTION Fire-suppression wet and manual dry standpipes. 1.2 SCOPE OF WORK SECTION 21 12 00 A. Design, installation and testing shall be in accordance with NFPA 14 except for specified
More informationPHIREX AUSTRALIA CATALOGUE & DATA SHEETS. April 2005, Rev 2. Fogex Water Mist Fire Protection System Components PHX-3064
CATALOGUE & S April 2005, Rev 2 PHX-3064 Fogex Water Mist Fire Protection System Components Fogex F11 Water Mist Nozzle Fogex F11 Water Mist Nozzle Features Al. Bronze construction for added safety and
More informationSECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.
SECTION 15481 COMPRESSED AIR SYSTEM PART 1 - GENERAL 1.1 SECTION INCLUDES A. Pipe and pipe fittings, including valves, unions and couplings. B. Air compressor. C. After cooler. D. Refrigerated air dryer.
More informationD. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationESCUTCHEON PLATE SEATING 3/4" NPT SURFACE. 1-1/2" (38,1 mm) CROSS SECTION PENDENT RECESSED PENDENT
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 6.9 K-factor, Pendent/Recessed Pendent/Concealed, NFPA 13 Optimized Wet Pipe Systems General Description The TYCO
More informationConstruction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA
Construction Standards Page 233423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified
More informationO-RING UPRIGHT SHIELD WRENCH FLATS WRENCH FLATS FIGURE 1 SERIES TY-B UPRIGHT (TY3153) AND PENDENT (TY3251) SPRINKLERS
Worldwide Contacts www.tyco-fire.com Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description The Series TY-B, 5.6 and 8.0 K-factor Upright
More informationB. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationSeries EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description
Worldwide Contacts www.tyco-fire.com Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K and Pendent Extended Coverage Light and Ordinary Hazard General Description TYCO Series EC-11 and EC-14 Extended
More informationA. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.
SECTION 23 21 23 - HYDRONIC PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationMIRAGE EC/QREC OH-ELO CONCEALED PENDENT SPRINKLER VK538 (K11.2) TECHNICAL DATA
Page 1 of 6 1. DESCRIPTION Viking Mirage EC/QREC ELO Concealed Pendent Sprinkler VK538 is a thermosensitive solder link spray sprinkler designed for installation on concealed pipe systems where the appearance
More informationSprinkler Identification Numbers
Worldwide Contacts www.tyco-fire.com Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K and Pendent Extended Coverage Light and Ordinary Hazard General Description Extended Coverage and Pendent Sprinklers
More informationWest District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8
City of Ottawa Project No. CR006230 Page 1 of 8 PART 1 - GENERAL 1.1 Reference Standards.1 Conform to the following:.1 Provincial and municipal building and fire regulations as approved by Provincial Fire
More informationSeries TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description
Worldwide Contacts www.tyco-fire.com Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description The Series TY-B, 5.6 and 8.0 K-factor Upright
More informationTECHNICAL. Series 18. Pump Packages
TECHNICAL S Y S T E M S Series 18 Pump Packages Series 18 Pump Packages Standard Features Close-coupled, end-suction, centrifugal pumps Mounted and wired pump starters Hand-Off-Auto switch for each pump
More informationRAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description Pendent Sprinklers (TY2524)
More informationA. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.
SECTION 23 70 00- CENTRAL HVAC EQUIPMENT PART 1: GENERAL 1.1 PURPOSE: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.
More informationModel G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler
UL Quick Response FM Standard Response ½ (13mm) Cover plate Adjustment Features 1. Flat cover plate with threaded attachment. 2. Solid or perforated cover plate available in chrome and white as Standard
More informationESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION
Worldwide Contacts www.tyco-fire.com Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K and Pendent Extended Coverage Light and Ordinary Hazard General Description Extended Coverage and Pendent Sprinklers
More informationmirage standard response concealed pendent sprinkler vk492 (K5.6)
Page 1 of 6 1. DESCRIPTION Viking Mirage Standard Response Concealed Pendent Sprinkler VK492 is a thermosensitive glass-bulb spray sprinkler designed for installation on concealed pipe systems where the
More informationTECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed.
Page 1 of 10 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Dry Pendent Sprinkler VK504 is a fast response fusible element type sprinkler designed for use in storage areas subject to freezing
More informationModel G5 Series Sprinkler Summary. Listings and Approvals. G4/G5 QR Gasket culus QR G4/G5 SR Gasket culus, FM SR G4/G5
Bulletin 034 Rev. F Model G5 Series Sprinklers Available with Solid, Perforated, or Gasket Standard Coverage, Concealed Pendent K2.8, 4.2, 5.6, & 8.0 (40, 60, 80, & 115 metric) Product Features Model G5
More informationSprinkler Identification Number (SIN)
Worldwide Contacts www.tyco-fire.com Series DS-3 Dry-Type Sprinklers 11.2K Horizontal Sidewall Standard Response, Extended Coverage General Description TYCO Series DS-3 Dry-Type Sprinklers, 11.2K Horizontal
More informationB. Related Sections: The following Sections contain requirements that relate to this Section.
SECTION 211313- FIRE-SUPPRESSION PIPING PART1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general prov1s1ons of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationModel ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage
Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage General Description
More informationWRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems General Description The TYCO RAPID RESPONSE Series
More informationFREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA
Page 1 of 5 1. DESCRIPTION Viking Freedom Residential Concealed Pendent VK494 is a small thermosensitive, glass-bulb residential sprinkler designed for installation on concealed pipe systems where the
More informationThe Series LFII (TY3596) Residential
Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series LFII Residential Concealed Pendent Sprinklers, Flat Plate 4.9 K-factor General Description The Tyco Rapid Response Series LFII (TY3596)
More informationSeries EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description
Worldwide Contacts www.tyco-fire.com Series EC-8 8.0 K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description Pendent Sprinklers are decorative glass bulb sprinklers
More informationINSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA
August 14, 2013 Sprinkler 126k 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Flush Horizontal Sidewall Sprinklers are small, flush, solder link and lever sprinklers made with tamper-resistant
More informationBAND HEATERS component parts
BAND HEATERS w w w.wat tco.com OVERVIEW WATTCO band heaters are the ideal solution for high watt densities and high operating temperature applications, especially for the plastics industry. The various
More informationesfr dry pendent sprinkler Vk501 (k14.0)
September 13, 2012 Sprinkler 122a 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Dry Pendent Sprinkler VK501 is a fast response fusible element type sprinkler designed for use in storage
More informationRAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems General Description The TYCO RAPID RESPONSE Series
More informationSECTION PLUMBING EQUIPMENT
PART 1 GENERAL 1.1 SECTION INCLUDES A. Water heaters B. Packaged water heating systems C. Water storage tanks D. Water softeners E. Pumps F. Circulators 1.2 REFERENCES SECTION 22 30 00 PLUMBING EQUIPMENT
More informationDATASHEET HIGH VOLUME LONG RANGE FOAM MONITOR GPM
DATASHEET HIGH VOLUME LONG RANGE FOAM MONITOR REV DESCRIPTION BY CHK DATE DOC. VFCPL/ONGC/SEL /500-750-1000/01 SHT No 1 of 6 A HIGH VOLUME LONG RANGE FOAM MONITOR MONITOR 1. GENERAL REQUIREMENT :- 1.1
More informationMODEL WALL MOUNT AUTOPSY STATION DOUBLE SINK
STANDARD DESIGN FEATURES Width:...29 in./74 cm. Length:...132 in./335 cm. Working Height:...34 in./86 cm. All stainless steel construction with heliarc-welded seams and joints, ground and polished to a
More informationPOWER TOWER SERIES Fiberglass Construction 45 to 540 Tons
Temperature Control Units Water & Oil 0-500 F Portable Chillers Air & Water-Cooled 0-70 F Central Chillers Air & Water-Cooled Packages & Modules 0-70 F Pump Tank Stations Chilled or Tower Water 00-00 gallons
More informationSteel Casework Acid Storage
STORAGE CABINETS Acid Storage Units (18 Deep) Acid Storage Units (22 Deep) See page E17 for vent hole locations. 15 1931011 1931211 1 18 1131011 1131211 1 24 1231011 1231211 1 30 1331011-2 36 1431011-2
More informationWALL MOUNT AUTOPSY STATION CENTER SINK
MODEL 1036-10 WALL MOUNT AUTOPSY STATION CENTER SINK STANDARD DESIGN FEATURES Width:...29 in./74 cm. Length:...114 in./289 cm. Working Height:...34 in./86 cm. All stainless steel construction with heliarc-welded
More informationesfr pendent sprinkler vk510 (k25.2)
Page 1 of 7 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Pendent Sprinkler VK510 incorporates the capability to suppress specific high-challenge fires. The addition of a larger K-Factor
More informationproven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential 4.9 K-factor Pendent Sprinkler Wet Pipe and Dry Pipe Systems General Description TYCO RAPID RESPONSE Series Recessed Pendent
More informationSECTION SPLIT-SYSTEM AIR-CONDITIONERS
SECTION 23 81 26 SPLIT-SYSTEM AIR-CONDITIONERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.
More informationStandard Spray concealed horizontal sidewall sprinkler VK481
Page 1 of 6 1. DESCRIPTION Viking Quick Response Concealed Horizontal Sidewall VK481 is a small solder link and lever spray sprinkler designed for installation on concealed pipe systems. The sprinkler
More informationculus Listed: Category VNIV Refer to the Approval Chart on page 3. VK697 Attic Upright Sprinkler Specifications:
Page 1 of 8 1. DESCRIPTION The Viking Attic Upright VK697 is a specific application attic sprinkler that provides superior fire protection in combustible and non-combustible sloped attic spaces when used
More informationDUKE UNIVERSITY CONSTRUCTION STANDARDS
1 22 40 00 Plumbing Fixtures 1. General A. Definitions 1. Section includes a. Water closets and urinals b. Lavatories, sinks, and service sinks c. Electric water coolers, drinking fountains, d. Showers
More informationA. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationB. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.
DIVISION 21 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, sleeves, escutcheons, seals, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS
More informationSECTION WET FIRE SPRINKLER SYSTEMS
SUNY GENESEO 211310-1 PART 1 - GENERAL 1.1 WORK INCLUDED A. Provide labor, materials, equipment and services to perform operations required for the complete installation and related Work as required in
More informationMicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA
Page 1 of 6 1. DESCRIPTION The Viking Fusible Element Horizontal Sidewall Sprinkler VK613 is a small thermosensitive solder link spray sprinkler available with various finishes and temperature ratings
More informationsprinkler vk538 (K11.2)
December 6, 2012 Sprinkler 89h 1. DESCRIPTION Viking Mirage EC/QREC ELO Concealed Pendent Sprinkler VK538 is a thermosensitive solder link spray sprinkler designed for installation on concealed pipe systems
More informationRAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems General Description LFII Residential Flush Horizontal Sidewall
More informationStorage Solutions. New Items Inside. High Capacity Cabinets Heavy Duty Shelf Cabinets Shop Desks Modular Mobile Cabinets Security Trucks
Storage Solutions New Items Inside Pages 9, 10 & 11 High Capacity Cabinets Order from Dick Jones Sales, Inc. P.O. Box 141 Hanover, PA 17331 Phone 800-441-9955 dickjones@dickjonessales.com Heavy Duty Shelf
More informationTMV45 & TMV80 Standard Thermostatic Mixing Valves
Reliable liquid-filled thermostat Integral strainer checkstops on inlets Adjustable set point within temperature range Accurate temperature control Positive shutoff of hot supply when cold supply is lost
More informationMIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA
Page 1 of 6 TECHNICAL DATA 1. DESCRIPTION Viking Mirage Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for
More informationMIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA
Page of 7 TECHNICAL DATA. DESCRIPTION Viking Mirage Standard and Quick Response Concealed Pendent VK6 and HP VK6 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe
More informationSTANDARD/quick. Sprinkler 42o. August 8, 2011
August 8, 2011 Sprinkler 42o 1. DESCRIPTION Viking Standard/Quick Response Concealed Fusible Element Pendent Sprinkler VK353 is a thermosensitive solder link spray sprinkler pre-assembled with a threaded
More informationUL LISTED. SPRINKLER HEADS IN STOCK: Pendent Upright Horizontal sidewall Concealed. RESPONSE Quick response Standard response
SPRINKLER HEADS SMOOTHFLOW AUSTRALIA SPRINKLER HEADS IN STOCK: Pendent Upright Horizontal sidewall Concealed RESPONSE Quick response Standard response COLOURS Natural brass Chromed Power coated white TEMPERATURE
More informationHL45, HL80 Thermostatic High-Low Valves
Lead-Free Brass Design Reliable Liquid-Filled Thermostat with 10 year warranty Integral Strainer Checkstops on Inlets Adjustable Set Point within Temperature Range Accurate Temperature Control to within
More informationSECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS
SECTION 22 34 00 (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS System shall provide a complete hot water return throughout the entire system with balancing (flow control) valves not less than 10 feet from
More informationBrown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS
SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett
More informationSECTION DOMESTIC WATER PUMPS
SECTION 22 11 23 DOMESTIC WATER PUMPS PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following all-bronze and bronze-fitted centrifugal pumps for domestic cold- and hot-water circulation: 1. Close-coupled,
More informationCO ALARMS GAS DETECTION HYDRANT BOOSTERS MOUNTS PUMP SOLUTIONS SUPPRESSION SYSTEMS. /fireprotection
FIRE PROTECTION CO ALARMS GAS DETECTION HYDRANT BOOSTERS MOUNTS SPRINKLER PUMP SOLUTIONS SUPPRESSION SYSTEMS Shop /fireprotection 1.800.323.0244 EDARLEY.COM/FIREPROTECTION FIRE PROTECTION HALOTRON I CLEAN
More informationSTANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA
Page 1 of 5 1. DESCRIPTION Viking EC/QREC Ordinary Hazard ELO Fusible Element Pendent Sprinkler VK537 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings
More informationModel ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description
Technical Services 800-381-9312 +1-401-781-8220 www.tyco-fire.com Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description The TYCO Model ESFR-17 Dry
More informationSTANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA
Page 1 of 6 1. DESCRIPTION Viking Standard/QREC Light Hazard ELO Fusible Element Pendent Sprinkler VK617 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings
More informationSprinkler Identification Number (SIN) TY4234. Page 1 of 8 APRIL 2012 TFP Technical Services
Technical Services 800-381-9312 +1-401-781-8220 www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 6.9 K-factor, Pendent/Concealed, NFPA 13 Optimized Wet Pipe Systems General Description
More informationSeries EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description
Worldwide Contacts www.tyco-fire.com Series EC-8 8.0 K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description Pendent Sprinklers are decorative glass bulb sprinklers
More informationSafety is more than just being careful: it
Remote controlled monitors - a smart and reliable answer for a safer protection Nico Zorzetto, Director Export e Marketing Sanco Spa Safety is more than just being careful: it includes knowing what is
More information