3M Oldham OLCT 100. Description. Fixed Gas Detector

Similar documents
OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

OLC(T) 100 FIXED GAS DETECTOR

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

GAS DETECTOR ST400EC PART.NO

Transmitters/Sensors. OLCT Series

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Sieger Apex. Flexibility that meets your requirements

Global Gas Detection and Monitoring Solutions

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

3M Oldham MX 43 Controller

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

Meridian. Universal Gas Detector. Description. Features. Minimal drift High specificity Digital ID Broader toxic gas detection

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Monitores Personales. Personal Monitor

Detection, Protection, Innovation

OLCT 10N. Digital Gas Detector. User Manual. The Fixed Gas Detection Experts. Part Number: NPO10NEN Version: G.1

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

ESD500. ESD500 Combustible / Toxic Gas Detector

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

SIL 2. Ultima X Series Gas Monitors CERTIFIED

ESD3000 ESD200 Combustible / Toxic Gas Detector

SP-220. Features. Combustible handheld gas leakage detector

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

Series 3000 XPIS. 2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres

Model D12. Digital Gas Transmitter

P R O D U C T D ATA S H E E T

ALTAIR 5X Multigas Detector Product Specification

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

ULTIMA X5000. MSAX5000.com

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

incontrol Systems Inc. Flame and Gas Detection

S5000 Gas Monitor. GMS5000.com

Dräger Polytron 8000 Stationary gas detector (EC)

User manual CTX 300 Analogic Gas Detector

MICRO III (G202 / G202s / G212) Single Gas Detector

Dräger PEX 3000 Flammable Gas Detection

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 5720 IR Toxic Gas Detection

Toxic Gas Detection. Model F12. Toxic Gas Detection

User manual CTX 300. Analogic Gas Detector. The Fixed Gas Detection Experts. Part Number: NP300GB Revision: K.1

OLCT IR TECHNICAL MANUAL INFRARED DETECTOR FOR FLAMMABLE GASES OR CO 2. The Fixed Gas Detection Experts. Part Number : NPOIRGB Revision : E

OLCT IR TECHNICAL MANUAL INFRARED DETECTOR FOR FLAMMABLE GASES OR CO 2. The Fixed Gas Detection Experts. Part Number : NPOIRGB Revision : G.

Single Gas Detector. Long-term solution H 2 S O 2 SO 2 NH 3 PH 3. Cl 2. ClO 2 NO 2 HCN ETO O 3

Micro III (Models G203, G203S, and G213) Operation Manual

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

G-TECTA TM. Portable Gas Detection Instruments

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

ALTAIR 5X Multigas Detector

Dräger X-am 5000 Multi-Gas Detection

TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

Zareba Sensepoint Pro

Satellite XT. Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 5100 EC Detection of toxic gases and vapors

MERIDIAN UNIVERSAL GAS DETECTOR

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)

Fixed Gas & Flame Detection International Product Range Overview

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger X-am 7000 Multi-Gas Detection

An easy and flexible way to do gas detection.

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Flame 2100 Flame Detection

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Industrial Grade Gas Detection Detecting The Difference

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Ordering Information. Ordering Information. Transmitter S3KUX S3KAX

Micro IV Operation Manual

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

Warranty Registration

MICRO IV. Operation Manual. Single Gas Detector

Dräger PIR 7000 Flammable Gas Detection

Transcription:

Fixed Gas Detector Description The OLC/OLCT range of fixed detectors has been designed for detection of combustible gases, toxic gases or oxygen. Available in explosion-proof or intrinsically safe versions, the OLCT is suitable for detection of all gases in ATEX zones. The OLCT is available in a stainless steel version, offering increased resistance to corrosive elements (ideal for marine, wastewater treatment plants, food processing activities, etc). This stainless steel intrinsically safe version is certified for use in zones 0 (gas) and 20 (dust), whereas all other versions of the OLCT are certified for use in zones 1 (gas) and 21 (dust). Features Detection of Combustible, Toxic or Oxygen gases Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version Applications Steel mills Petrochemical facilities Chemical industry Pharmaceutical industry Food industry Refrigeration industry Water treatment

Our products are always application-driven, solution-oriented. Options include: OLCT transmitter with 4-20 ma output OLC detector with a Wheatstone bridge output for detection of combustible gases IR Sensor The infrared sensor provides detection of CO2 and refrigerant gases and is warranty 2 years. 2

OLCT XP Explosion-proof version is equipped with a catalytic, electrochemical or semiconductor sensor, for detection of combustible, toxic gases or oxygen. OLCT IS CO2 OLCT XP IR Intrinsically safe version is equipped with an electrochemical sensor for detection of toxic gases or oxygen. OLCT XP IR Explosion-proof IR version is equipped with an infrared sensor for detection of CO 2, SF 6 and some freons. GAS HAZARD R134a, R1234yf, R407f SF 6 Combustible Toxic or O2 OLCT XP IR OLCT XP IR OLC OLCT XP HT OLCT XP OLCT XP OLCT IS OLCT XP HT High temperature explosion-proof version for detection of combustible gases up to 200 C. High temperature cable included: 5, 10, 15 meter lengths. Reliability The OLCT is SIL 2 certified by INERIS, according to the EN 50402 standard, which corresponds to IEC/EN 61508 for gas detectors. Gas Measure SIL Capability λ DU PFD avg Test Period Combustibles (a) Catalytic (C0) SIL 2 0,189.10-6 8.3 10-4 12 months O (b)(c) 2 Electrochemical SIL 2 0.74 10-6 1.62 10-3 6 months CO (b) Electrochemical SIL 2 1.09 10-6 1.19 10-3 3 months H 2 S (b) Electrochemical SIL 2 2.98 10-6 3.26 10-3 3 months (b) NH 3 Electrochemical SIL 2 4.48 10-6 4.91 10-3 3 months (a) complete unit, according to certificate INERIS No. 93664/2012 (b) software and hardware according to certificate INERIS No. 93664/2012, sensors data according to proven in use (c) O2 sensor with 28 months life expectancy

Gas Measuring Range (ppm) XP Version IS Version Temperature Range ( C) % RH Accuracy (ppm) Average Life Expectancy (month) Response Time T 50 /T 90 (s) Storage Condition Combustible Gases Catalytic 0-% LEL -40 to +70 0-95 +/- 1% LEL (from 0 to 70% LEL) 40 6/15 (CH 4 ) (b) Catalytic High Temperature 0-% LEL -20 to +200 0-95 +/- 1% LEL (from 0 to 70% LEL) 40 6/15 (CH 4 ) (b) AsH 3 Arsine 1.00-20 to +40 20-90 +/- 0.05 18 30/120 (a) CH 2 O Formaldehyde 50.0-20 to +50 15-90 +/- 1.0 36 50/240 (a) Cl 2 Chlorine 10.0-20 to +40 10-90 +/- 0.4 24 10/60 (a) ClO 2 Chlorine dioxide 3.00-20 to +40 10-90 +/- 0.3 24 20/120 (a) CO CO 2 Carbon monoxide Carbon dioxide 300 0 0-5000ppm 0-5% vol. 0-10% vol. 0-% vol. -20 to +50 15-90 +/- 3 (range 0-) 40 15/40 (a) -20 to +40 10-90 +/- 3% 48 20/120 (a) COCl 2 Phosgene 1.00-20 to +40 15-90 +/- 0.05 12 60/180 (c) ETO Ethylene oxide -20 to +50 15-90 +/- 1.0 36 50/240 (a) H 2 Hydrogen 2000-20 to +50 15-90 +/- 5% 24 30/50 (a) H 2 S HCl Hydrogen sulfide Hydrochloric chloride 0-40 to +50 15-90 +/- 1.5 (range 0-30) 36 15/30 (a) -20 to +40 15-95 +/- 0.4 (range 0-10) 24 30/150 (a) HCN Hydrogen cyanide 10.0-40 to +40 15-95 +/- 0.3 (range 0-10) 18 30/120 (c) 0-40 to +40 15-90 +/- 20 24 -- NH 3 Ammonia 0 5000-20 to +40 15-90 +/- 5 +/- 20 +/- 150 or 10% 24 25/70 20/60 60/180 (a) NO Nitrogen monoxide 300 0-20 to +50 15-90 +/- 2 (range 0-) 36 10/30 (a) NO 2 Nitrogen dioxide 10.0-20 to +50 15-90 +/- 0.8 24 30/60 (a) O 2 Oxygen 0-30% vol -20 to +50 15-90 0.4% Vol (from 15 to 22% O 2 ) 28 6-15 0-30% vol -40 to +50 10-90 +/-1,5% 60 15/25 PH 3 Phosphine 1.00-20 to +40 20-90 +/- 0.05 18 30/120 SiH 4 Silane 50.0-20 to +40 20-95 +/- 1.0 18 25/120 (a) SO 2 Sulphur dioxide 10.0-20 to +50 15-90 +/- 0.7 (range 0-10) 36 15/45 (a) CH 3 Cl Methyl chloride 500-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) CH 2 Cl 2 Methylene chloride 500-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Freon R12 1% vol -20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Freon R22 2000-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Freon R123 2000-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) FX56 2000-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Freon R134 a 2000-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) 2000ppm (IR) -20 to +50 0-95 +/- 40ppm (from 0 to 50% range) 60 40/170 (e) Freon R11 1% vol -20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Freon R23 1% vol -20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Freon R143a 2000-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Freon R404 a 2000-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Freon R507 2000-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Freon R410a 0-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Freon R32 0-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Freon R407c 0-20 to +60 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) (a) (a) Freon R407f 0-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) 2000 (IR) -20 to +50 0-95 +/- 40ppm (from 0 to 50% range) 60 40/105 (e) Freon R408a 0-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Ethanol 500-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Toluene 500-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Isopropanol 500-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) 2-butanone (MEK) 500-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Xylene 500-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) SF6 2000 (IR) -20 to +50 0-95 +/- 40ppm (from 0 to 50% range) 60 25/120 (e) 0-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) R1234yf (HFO) 2000 (IR) - 20 to +50 0-95 +/- 40ppm (from 0 to 50% range) 60 25/120 (e) 0-% LEL (IR) - 20 to +50 0-95 +/- 2% LEL (from 0 to 50% LEL) 60 30/115 (e) R1234ze 0-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) (a) +4 C to +20 C / 20 % to 60% HR (b) -50 C to +70 C / 20 % to 60 % HR (c) +4 C to +20 C / 20 % to 60 % HR (d) -20 C to +50 C / 20 % to 60 % HR (e) -40 C to +85 C / 0-80% RH 1 bar ± 10 % / 6 month maximum 1 bar ± 10 % / 6 month maximum 1 bar ± 10 % / 3 month maximum 1 bar ± 10 % / 6 month maximum 1 bar ± 10 % / 6 month maximum

Model OLC OLCT XP OLCT XP IR OLCT XP OLCT XP HT OLCT XP OLCT IS Sensor Catalytic bead Catalytic bead Infrared Electrochemical Catalytic bead Semi-conductor Electrochemical Material Epoxy-coated aluminium housing (Inox 316L optional). 316 stainless steel sensors Dimensions (mm) (inches) 135 x 133 x 84 5.43 x 5.24 x 3.31" 135 x 133 x 84 5.43 x 5.24 x 3.31" 150 x 138 x 84 5.91 x 5.43 x 3.31" Weight (kg) 0.95 1 1.1 1.1 1.8 1.1 1.1 Ingress Protection Cable Entry Supply Voltage only by OLDHAM Controller IP66 M20 or ¾ NPT 15.5 to 32 VDC 13.5 to 32 VDC 10 to 32 VDC 15.5 to 32 VDC 15.5 to 32 VDC 15.5 to 32 VDC Average Consumption 340 ma 110 ma 60 ma 23.5 ma ma ma 23.5 ma Pressure atmospheric ± 10% Output signal Usual source encoded from 0 to 23 ma (not isolated) - linear 4 to 20 ma output, reserved for measurement - 0 ma : electronic fault or no power supply - < 1 ma: fault - 2 ma: initialization mode - > 23 ma: out of range Approvals Compliant with European directive ATEX 2014/34/EU and with IECEx schedule for explosion-proof detectors. OLC, OLCT XP, OLCT XP IR : ATEX II 2 GD / Ex d IIC T6 Gb / Ex tb IIIC T85 C Db IP66 OLCT XP HT: ATEX II 2 GD / Ex d IIC T6 Gb / Ex tb IIIC T85 C Db IP66 (for the transmitter to be installed in a cold zone) ATEX II 2 G / Ex d IIC T4..T2 Gb (for the sensor to be installed in the hot zone) OLCT IS Aluminum : ATEX II 2 GD / Ex ia IIC T4 Gb / Ex ia IIIC T135 C Db IP66 OLCT IS Stainless Steel : ATEX II 1 GD / Ex ia IIC T4 Ga / Ex ia IIIC T135 C Da IP66 SIL 2 according to EN 50402 / EN 61508 for catalytic versions, O2, CO, NH3 and H2S Metrological performances according to EN/IEC 60079-29-1 Electromagnetic compatibility according to EN 50270 Cable 2 active wires, 2 active wires,

Ordering Information The reference is broken down as follows: OLCT -XP-001-1 OLCT XP Transmitter, 0-% LEL CH 4, ATEX, M20 cable entry Range: Type: Gas: Approval and entry of cable range: OLC OLCT OLCT HT5* OLCT HT10* OLCT HT15* XP IS XPIR Codified from 1 to 999, includes gas and detection range 1 - ATEX and M20 cable entry - Aluminium 3 - ATEX and 3 / 4 NPT cable entry - Aluminium 5 - ATEX and M20 cable entry - Stainless steel 7 - ATEX and 3 / 4 NPT cable entry - Stainless steel *Sensor movable up to 5, 10, or 15 meters using a high temperature cable Accessories A Calibration cup (6331141) allows introduction of calibration gas on the sensor B Bypass adapter (6327910) allows measurement of samples C Splash guard system (6329004) protects the detector from liquid projections D Remote gas introduction head (6327911) allows introduction of gas without opening the detector E Removable protective filter (6335975) protects the sensor against projections and dust F Duct measurement kit (6793322) allows gas monitoring in a duct G Mounting bracket (6322420) allows the mounting of the detector to the ceiling H Protective cover (6123716) protects the detector against bad weather conditions or against direct sun radiations I Adapter plate (6793718) allows the replacement of another OLDHAM detector without re-drilling J Wall mounted collecting cone (6331169) for use with lighter-than-air gases K Ceiling mount collecting cone (6331168) for use with lighter-than-air gases A B C G H I D E F J K As an ISO 9001 & ISO 14001 approved company, OLDHAM quality assurance programmes demand the continuous assessment and improvement of all OLDHAM products. Information in this leaflet could thus change without notification and does not constitute a product specification. Please contact OLDHAM or their representative if you require more details. Americas - Texas (USA) 4055 Technology Forest Blvd. The Woodlands, TX 77381 Tel.: +1-800-247-7257 Fax: +1-281-292-2860 Emea ZI Est, Rue Orfila, CS 20417 62027 ARRAS CEDEX, France Tel.: +33-3-21-60-80-80 Fax: +33-3-21-60-80-00 Asia Pacific 290 Guiqiao Road Pudong, Shanghai 201206 People's Republic of China Tel.: +86-21-3127-6373 Fax: +86-21-3127-6365 Copyright 2018 3M, 3M Gas & Flame Detection. All rights reserved. gasdetection.3m.com. GF-30029G-EN