Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

Similar documents
Jul07 Rev C

Jun08 Rev C

Jun08 Rev A

Jan05 Rev A EC

Mar11 Rev B

Two Circuit Heavy Duty Burner Connector

Mar11 Rev C

Apr06 Rev A

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

Qualification Test Report LC Duplex Adapter For LC Cutouts

Jan07 Rev B

HMN-D2 Insert Series

FEB. 17 Rev. A1

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

/Oct/2014 Rev B

Plug shell and receptacle, single cavity, floating, EN Application of modular rectangular modules and shells per EN4165

/Oct/2014 Rev E

Cat 6 Shielded Patch cords

Cat 6 Unshielded Patch cords

/Mar/2014 Rev A

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

ETSI TS V1.2.1 ( )

Draft ES V1.1.1 ( )

ETSI TS V1.2.1 ( )

HOUSING ASSY 5 POS. HYBRID STD/JR POWER TIMER TAB & REC.

USB 3.0 Plug & Receptacle

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications :

APR 17 Rev A

Product Specification Qualification Test Report

MODULAR CONNECTOR 154 (58 AND 96) POS, WATERPROOF PRODUCT SPECIFICATION

JUL 18 Rev A1

INTERNATIONAL STANDARD

Product Specification CAT 6 UNSHIELDED PATCH CORDS

ITU-T L.404. Field mountable single-mode optical fibre connectors

Product Specification Mono-Shape TM Mark II - 5mm Pitch I.D.C Connectors, For TAB Contacts - RAST5

Technical Specification for the Mastic-Sealed Fiber-Optic Closure System (FOSC 300C)

Technical Specification for the Gel-Sealed Fiber-Optic Closure System (FOSC 450)

MT-RJ Optical Fiber System Field Testing

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

LOVAG TEST INSTRUCTION IEC/EN

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

CERTIFICATE of QUALITY TEST

Product Tests Report

TEST REPORT Report No.: HN80013/2011 Page: 1 of 7 Date: August 30, 2011

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links

COMITÉ EUROPÉEN DES ASSURANCES

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

23" PANEL MOUNT INDUSTRIAL MONITOR REVISION C PRODUCT RELIABILITY TEST REPORT

Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC. Philip C Longhurst Corporate Fibre Optic R & D Manager

Vibration tests on a TNAML Luminaire

17" UNIVERSAL MOUNT INDUSTRIAL MONITOR REVISION E, F & G PRODUCT RELIABILITY TEST REPORT

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

4120 Fire Alarm Network Reference

GR-326-CORE Singlemode Optical Connectors and Jumper Assemblies

ISO INTERNATIONAL STANDARD. Agricultural engineering Electrical and electronic equipment Testing resistance to environmental conditions

Qualification Test Report 1/Jul/2005 Rev. A

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

INTERNATIONAL STANDARD

Inverted Through Board Surface

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

SECTION (16460) - LOW-VOLTAGE TRANSFORMERS

ENVIRONMENTAL TEST REPORT

Hydraulic Crimping Head, PN

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2

The Rise of Tier 2 Testing

Hydraulic Crimping Heads and

INTERNATIONAL STANDARD

TEST REPORT Reliability Laboratory Report No.: HCD0203/2008

SolderSleeve Insulated Electrical Termination Devices

Special Provision No. 683S28 December 2017

SECTION GENERATOR PARALLELING CONTROLS

Hydraulic Crimping Head, PN

ECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

This is a preview - click here to buy the full publication

DRAFT TANZANIA STANDARD

Hydraulic Crimping Head, PN 69069

M7100 Pressure Transducer

SOLARLOK Interconnection System Installation Manual

SECTION ISOLATED POWER SYSTEMS

This instruction sheet covers the Hand Crimping Tools listed in Figure 1, which are used to crimp the terminal types listed in Figure 2.

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

INTERNATIONAL STANDARD

This document is a preview generated by EVS

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

Application Specification MAG-MATE* Poke-In Tab Terminals

INTERNATIONAL STANDARD

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear

Reasons for reissue are provided in Section 6, REVISION SUMMARY.

Wet alarm valve stations

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

Rules for Classification and Construction Additional Rules and Guidelines

TEMPORARY IMMERSION AND DUST TEST REPORT

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

SECTION Fluorescent Dissolved Oxygen Measuring System

Type approval testing of miscellaneous smoke and heat detectors for marine applications

INTERNATIONAL STANDARD

Transcription:

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming) 02Oct08 Rev A 1. SCOPE 1.1. Content This specification, based on IEC 61753-1 Edition 1.0 tests for Category E (Extreme Environment), covers the performance, tests and quality requirements for the Tyco Electronics EMI Shielded Duplex LC Sealed Receptacle (Open DeviceNet Vendor Association, Inc. (ODVA) Conforming). 1.2. Qualification W hen tests are performed on the subject product line, procedures specified in Figure 2 shall be used. All inspections shall be performed using the applicable inspection plan(s) and product drawing(s). 1.3. Qualification Test Results Successful qualification testing on the subject product line was completed on 24Apr08. The Qualification Test Report number for this testing is 501-682. This documentation is on file at and available from Engineering Practices and Standards (EPS). 2. APPLICABLE DOCUMENTS The following documents form a part of this specification to the extent specified herein. Unless otherwise specified, the latest edition of the document applies. In the event of conflict between requirements of this specification and the product drawing, the product drawing shall take precedence. In the event of conflict between requirements of this specification and referenced documents, this specification shall take precedence. 2.1. Tyco Electronics Documents! 102-952: Quality Specification (Qualification of Fiber Optic Connectors and Cable Assemblies)! 408-10079: Instruction Sheet (Sealed Circular LC Connector System - Plug Kit 1828618-[] and Receptacle kit 1985193-[])! 501-682: Qualification Test Report (EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)) 2.2. Commercial Standards! IEC 60068-1: Environmental Testing Part 1: General and Guidance! IEC 60529: Degrees of Protection Provided by Enclosures (IP Code)! IEC 61300: Fiber Optic Interconnecting Devices and Passive Components - Basic Test and Measurement Procedures! IEC 61726: Screening Attenuation Measurement by the Reverberation Chamber Method! IEC 61754-20: Fiber Optic Connector Interfaces - Part 20: Type LC Connector Family! TIA/EIA-455-B: Standard Test Procedure for Fiber Optic Fibers, Cables, Transducers, Sensors, Connecting and Terminating Devices, and Other Fiber Optic Components 2008 Tyco Electronics Corporation Harrisburg, PA All International Rights Reserved. * Trademark Indicates change For latest revision, visit our website at www.tycoelectronics.com\documents. For Regional Customer Service, visit our website at www.tycoelectronics.com 1 of 10 LOC B

3. REQUIREMENTS 3.1. Design and Construction Product shall be of the design, construction and physical dimensions specified on the applicable product drawing(s). 3.2. Optical Power Source Unless otherwise stated in the Qualification Test Report, the optical power source wavelength shall be 1310 ± 30 nm and 1550 ± 30 nm for singlemode. 3.3. Ratings Performance Value Singlemode Units Attenuation, typical (see Note) 0.06 db Return loss, typical (see Note) 56 db Operating temperature -40 to 85 C Storage temperature -40 to 85 C NOTE Typical values represent the median of the sample data. See Figure 2 for maximum insertion loss and minimum return loss requirements. Figure 1 3.4. Performance and Test Description Product is designed to meet the mechanical, environmental and optical performance requirements specified in Figure 2. Unless otherwise specified, all tests shall be performed at ambient environmental conditions. 3.5. Test Requirements and Procedures Summary Test Description Requirement Procedure Visual and mechanical inspection. Meets requirements of product drawing. Duplex LC receptacle complies with dimensional requirements of IEC 61754-20. No defects which would affect functionality. IEC 61300-3-1. Visual, dimensional and functional per applicable quality inspection plan. See Note (a). Rev A 2 of 10

Test Description Requirement Procedure Attenuation (new product). Return loss (new product). Change in attenuation. Singlemode: For one mated connector pair: Average attenuation for the group/lot is 0.25 db. Maximum attenuation is 0.50 db for > 97% of specimens. Maximum attenuation is 0.75 db for 100% of specimens. Singlemode: specimen is 40 db for pigtail specimens (one mated connector pair). As applicable to each test: Singlemode: Maximum change in attenuation is 0.2 db during and after test for pigtail specimens (one mated connector pair). IEC 61300-3-4. Launch and receive are both part of the pair under test and are not reference quality. Precondition by cleaning plug and adapter per manufacturer's instructions. Test at 1310 ± 30 nm and 1550 ± 30 nm for singlemode. For singlemode, only the fundamental mode shall propagate at the connector interface and at the detector. See paragraph 5.1. IEC 61300-3-6, branching device or OTDR method. Precondition by cleaning plug and adapter per manufacturer's instructions. Test at 1310 ± 30 nm and 1550 ± 30 nm for singlemode. See paragraph 5.1. IEC 61300-3-3, Method 1. Record attenuation before, during and after test as applicable to each test. Measure attenuation at 1310 ± 30 nm and 1550 ± 30 nm for singlemode, unless otherwise specified. Calculate change in attenuation during test as the difference between the maximum and minimum attenuation values recorded during test (peak-to-peak range). Calculate change in attenuation after test as the difference between the initial reference recorded at the start of each test and the final reading recorded at the end of each test. Rev A 3 of 10

Test Description Requirement Procedure Shielding effectiveness. Change of temperature. Dependent upon customer specific application. specimen is 0.50 db before, during Maximum change in attenuation for any single specimen is 0.2 db during specimen is 40 db before, during IEC 61726, 2nd edition dated 1999-11. Based on IEC 61726 guidelines, use two mode-stirred chambers designed for a minimum frequency of 3 GHz. Mount the test bezel with the adapter in a common wall. Mode stir the receive chamber at 12 RPM and the drive side at 360 RPM. Mount a sense antenna in receive chamber and mount identical drive antennas in both chambers. Measure the peak power for one complete revolution of the slower (12 RPM) mode stirrer by first driving the cable board side drive antenna and then the cable side drive antenna. Calculate the ratio of these two values and report Cabinet Ambient Shielding Effectiveness (CA-SE) in db. Plot CA-SE from 1 to 15 GHz. IEC 61300-2-22 and IEC 68-2-14, Test Nb. Maintain specimens undisturbed in the chamber at room ambient (23 ± 5 C and 20 to 70% RH) for 2 hours prior to recording initial attenuation and return loss. A minimum of 3 m [9.8 ft] cable length shall be inside the test chamber (> 1.5 m [4.9 ft] on each side of the connector for pigtail specimens). Using a ramp rate of 1 C per minute, subject specimens to 12 cycles between -40 ± 2 C and 85 ± 2 C with 1 hour dwells at each extreme. Attenuation and return loss shall be measured before test, at a maximum interval of 10 minutes throughout the exposure, Maintain specimens undisturbed for at least 2 hours after the chamber's return to ambient conditions, before measuring final attenuation and return loss. See paragraph 5.2. Rev A 4 of 10

Test Description Requirement Procedure Temperature/humidity cycling. Mixed flowing gas. specimen is 0.50 db before, during Maximum change in attenuation for any single specimen is 0.2 db during specimen is 40 db before, during specimen is 0.50 db after test. specimen is 40 db after test. See Notes (b) and (c). IEC 61300-2-21 and IEC 68-2-38, Test Z/AD with exposure to cold. After pre-conditioning, maintain specimens undisturbed in the chamber at room ambient (23 ± 5 C and 20 to 70% RH) for 2 hours prior to recording initial attenuation and return loss. A minimum of 3 m [9.8 ft] cable length shall be inside the test chamber (> 1.5 m [4.9 ft] on each side of the connector for pigtail specimens). Profile temperature extremes are -10 ± 2 C and +65 ± 2 C, with 93 ± 3% RH at the maximum temperature. Dwell at each temperature extreme for 3 hours. Perform 10 total cycles, with cold shock included in 5 of the first 9 cycles. Attenuation and return loss shall be measured before test, at a maximum interval of 10 minutes during test Maintain specimens at ambient conditions for a minimum of 24 hours, before measuring final attenuation and return loss. See paragraph 5.2. IEC 60068-2-60, Method 1. 96 hours duration, sulphur dioxide -9 (SO 2 500x10 ) and hydrogen -9 sulphide (H2S 100x10 ). The apparatus consists of a test chamber in accordance with IEC 60068-2-60, Test Ke. Corrosive monitoring copper coupons shall be used. Mount receptacle to water-tight enclosure and tighten the receptacle panel nut to the appropriate torque specified in the Instruction Sheet. Subject specimen to the test in a non-operational mode with protective cover applied to the receptacle. Upon completion of the test, the specimen shall be examined visually and all observations recorded. Measure attenuation, return loss and EMI shielding effectiveness after test. See Note (c). Rev A 5 of 10

Salt mist. Test Description Requirement Procedure Durability (bayonet). specimen is 0.50 db after test. specimen is 40 db after test. specimen is 0.50 db before, during Maximum change in attenuation for any single specimen is 0.2 db during specimen is 40 db before, during IEC 61300-2-26 and IEC 68-2-11, Test Ka. 96 hours duration, salt solution 5% NaCl (ph between 6.5 and 7.2) at 35 C. Mount receptacle to water-tight enclosure and tighten panel nut to the appropriate torque specified in the Instruction Sheet. Subject specimen to the test in a non-operational mode with protective cover applied to the receptacle. Upon completion of the test, the specimen shall be examined visually and all observations recorded. Careful attention shall be given to look for cracking and delamination of finishes and phenomena such as scratches and pitting, which are indicative of the removal of the protective coating. Measure attenuation, return loss and EMI shielding effectiveness after test. IEC 61300-2-2. Subject specimen to 500 cycles. A cycle shall consist of one full engagement and separation of the coupling mechanism to be evaluated (unmate/mate sealed circular LC ODVA plug from receptacle). The minimum time between each engagement and separation shall be 3 seconds. Attenuation and return loss readings shall be recorded every 50 matings after cleaning. Rev A 6 of 10

Dust protection. Test Description Requirement Procedure Temporary water immersion. No observable ingress of dust past the panel mounting or within the receptacle upon test completion. specimen is 0.50 db after test. specimen is 40 db after test. No accumulated ingress of water within the enclosure and connector, which could reach live parts. specimen is 0.50 db after test. specimen is 40 db after test. See Notes (b) and (c). IEC 60529, International Protection Code IP6X, Category 1, 8 hour duration, talcum powder. Specimen configuration: unmated receptacle with cap. Mount receptacle to a panel and tighten the receptacle panel nut to the appropriate torque specified in the Instruction Sheet. Subject specimen to the test in a non-operational mode with protective cover applied to the receptacle. Talcum powder used shall be able to pass through a square-meshed sieve the nominal wire diameter of which is 50 m and the nominal width of a gap between wires is 75 m. Dust circulation shall attempt to draw dust to the other side of the mounting panel. Maximum atmospheric depression 2 kpa [0.29 psi]. Upon completion of the test, the specimen shall be examined visually and all observations recorded. Measure attenuation, return loss and EMI shielding effectiveness after test. IEC 60529, International Protection Code IPX7, 30 minutes. Specimen configuration: unmated receptacle with cap. Mount receptacle to water-tight enclosure of height less than 850 mm [33.5 in], and tighten the receptacle panel nut to the appropriate torque specified in the Instruction Sheet. Subject specimen to the test in a non-operational mode with protective cover applied to the receptacle. Immerse the enclosure, such that the lowest point is located 1000 mm [39.4 in] below the water surface and the highest point of the enclosure is a minimum depth of 150 mm [5.9 in] below the water surface. Upon completion of the test, the specimen shall be examined visually and all observations recorded. Measure attenuation, return loss and EMI shielding effectiveness after test. See Note (c). Rev A 7 of 10

Impact. Vibration. Test Description Requirement Procedure specimen is 0.50 db before and after test. Maximum change in attenuation for any single specimen is 0.2 db after test. specimen is 40 db before and after test. specimen is 0.50 db before and after test. Maximum change in attenuation for any single specimen is 0.2 db after test. specimen is 40 db before and after test. IEC 61300-2-12, Method B. Subject unmated receptacle to 5 drops onto a steel plate from a height of 1.5 m [5 ft]. Randomize receptacle orientation for each drop. Measure attenuation and return loss before and after the test. Clean specimen before mating for final readings. See paragraph 5.1. IEC 61300-2-1 and IEC 68-2-6, Test Fc. Subject mated specimens to 15 sweeps over the frequency range of 10 Hz to 55 Hz and back to 10 Hz. Sweep rate shall be 1 octave per minute. Amplitude 0.75 mm. Specimen shall be vibrated in three mutually perpendicular axes. Measure attenuation and return loss before and after the test. Clean specimen before mating for final readings. See paragraph 5.1. NOTE (a) (b) (c) Dimensions not measured on actual test specimens are covered by First Article approval, which includes verification of product drawings per the dimensions specified in IEC 61754-20. Shall meet visual requirements, show no physical damage, and shall meet the requirements of additional tests as specified in the Product Qualification Test Sequence in Figure 3. Optical measurements after test may be delayed until the end of the test sequence. Figure 2 (end) Rev A 8 of 10

3.6. Product Qualification Test Sequence After visual and mechanical inspection, specimens shall first be tested for initial attenuation and return loss on new product, after which the remaining tests may be performed in any order. The groups and sequencing shown below is the suggested test plan. Test Groups (a) Test or Examination 1 2 3 4 Test Sequence (b) Visual and mechanical inspection 1 1 1 1 Attenuation 3,7 3,7 3 Return loss 4,8 4,8 4 Shielding effectiveness 2,5 2,9 2,9 2,8 Change of temperature 3 Temperature/humidity cycling 4 Mixed flowing gas 5 Salt mist 6 Durability (bayonet) 7 Dust protection 6 Temporary water immersion 5 Impact 5 Vibration 6 NOTE (a) (b) (c) Numbers indicate sequence in which tests are performed. See paragraph 4.1.A. A specimen consists of a mated duplex pair, except where noted in Figure 2 (such as a capped receptacle for sealing tests). Figure 3 4. QUALITY ASSURANCE PROVISIONS 4.1. Qualification Testing A. Specimen Selection Specimens shall be prepared in accordance with the applicable Instruction Sheets and shall be selected at random from current production. Specimen shall be defined as an EMI Shielded Duplex LC Sealed Receptacle that is ODVA conforming. B. Specimen Quantity Specimen quantity shall be a minimum of 5 for each individual test. C. Test Sequence Qualification inspection shall be verified by testing specimens as specified in Figure 3. Rev A 9 of 10

4.2. Requalification Testing If changes significantly affecting form, fit or function are made to the product or manufacturing process, product assurance shall coordinate requalification testing, consisting of all or part of the original testing sequence as determined by development/product, quality and reliability engineering. 4.3. Acceptance Acceptance is based on verification that the product meets requirements of Figure 2. Failures attributed to equipment, test setup or operator deficiencies shall not disqualify the product. When product failure occurs, corrective action shall be taken and specimens resubmitted for qualification. Testing to confirm corrective action is required before resubmittal. 4.4. Quality Conformance Inspection The applicable quality inspection plan will specify the sampling acceptable quality level to be used. Dimensional and functional requirements shall be in accordance with the applicable product drawing and this specification. 5. SPECIAL INSTRUCTIONS 5.1. Cleaning If at any time, a receptacle specimen is uncoupled from its LC connector test leads during qualification testing, the optical interfaces shall be cleaned according to the applicable Instruction Sheet prior to any subsequent optical measurements. Additional cleaning techniques deemed necessary by Product Engineering shall be described in the Test Report. If, after cleaning the connector as prescribed, loss performance exceeds the specified limit, or, if the operator suspects the presence of debris at the optical interface, perform the cleaning procedure a second time. If the resultant optical reading still exceeds the specification, clean the interface a third time and accept that reading. 5.2. Control Cables Control cables shall be subjected to climatic environmental tests. Transmittance shall be recorded each time a specimen transmittance is made. Changes in control cable power of less than 0.05 db may be neglected in the test specimen power and loss calculations. If control cable power changes by more than 0.05 db during the duration of the test or sequence of tests, change in control cable power should be included in power and loss calculations per TIA/EIA-455-20B. Rev A 10 of 10