CONTINUOUS MONITORING IS ON THE RISE:

Similar documents
PD alarm system brings peace of mind in Malta

NFPA 70B and CSA Z463 Standards for Electrical Maintenance Where Does Airborne Ultrasound Fit In?

IEEE Transformer Committee PC Distribution Transformer Monitoring - User

Reducing Arc Flash Risks with Electrical Maintenance Safety Devices - Part 2

Monitoring of Electrical Equipment Failure Indicators and Alarming

Continuous, real-time detection, alarming and analysis of partial discharge events

Case Study. A Geothermal Energy Generation Facility Embraces Infrared. Polymer Window Inspections. Overview: iriss.com

Engineering Design & Testing Corp./EDT Engineers, P.C.

Delta T Alert: Wireless Temperature Monitoring of Electrical Enclosures

Case Study. Custom Solutions for High Arc Flash Incident Energy and. Interlocked Electrical Enclosures. Overview: iriss.com

Healthcare Electrical Reference Architecture for Large Hospitals in North America

DISTRIBUTION OPERATIONS AND MAINTENANCE

White Paper. Reducing Arc Flash Risks with Electrical Maintenance. Safety Devices. Abstract: iriss.com

Enhancing Current Maintenance Practices 04. Managing the Risk 06. Constant Monitoring of Electrical Enclosures 08

Frequently asked questions: Intelligent Transmitter Series

NFPA 70B and the Importance of Electrical Predictive Maintenance

Guide to Transmission Equipment Maintenance

Risk Mitigation of Aging Electrical Infrastructure

A Powerful Case for Infrared Windows

Arc Flash Mitigation Solutions: A Proactive Approach To Arc Flash Risk

Why Selective Coordination is Mandatory -- It Fills the Reliability Hole --

Emerson s Pervasive Sensing strategies enable plants to realize full potential of Industrial IoT

Predictive Maintenance Training

i-con Switchgear Condition Monitoring HV Switchgear Integrated Substation Condition Monitoring ISCM Answers for Infrastructure & Cities.

Why Should You Invest In An Access Management System?

This section applies to the use of cord- and plug-connected equipment, including cord sets (extension cords).

ENERGY PRODUCTS DIVISION. Polymeric Surge Arresters Reliable protection for power equipment upto 800kV

Why are infrared cameras indispensable for building inspections?

White Paper. Maintenance Inspection Windows on Transformers. Maintenance Inspection Windows on Transformers. Abstract: iriss.com

SIL DETERMINATION AND PROBLEMS WITH THE APPLICATION OF LOPA

Combining Old and New Systems in Existing Buildings and Other Retrofit Tales. By Paul Jewett CFAA Technician Number 11

NPS/003/030 Technical Specification for Transformer and Switchgear Cable Boxes and their associated Bushing Assemblies

Wagner Meters has been an industry leader for over 40 years, creating innovative top-of-theline moisture measurement equipment.

EEI 2018 Edison Award Nomination Submitted

MANNED GUARDING. CALL US today for a FREE Quotation on +971 (4) Dubai, UAE

Hunting the Mighty Milliwatt- The next Technology Step

The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise

White Paper Study on Refrigerator Safety and Solving Airflow Problems Are Your Refrigerators Really Safe?

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Substation Monitoring System

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

MODULAR TRACTION SUBSTATIONS CITY ELECTRIC TRANSPORT

Totally Wireless Video Security

HIGH-VOLTAGE CABLE TESTING: TYPE TEST EXPERIENCES AND NEW INSIGHTS INTO PRE-QUALIFICATION

D1000 Arc-fault Protection System

SYNERGY IN LEAK DETECTION: COMBINING LEAK DETECTION TECHNOLOGIES THAT USE DIFFERENT PHYSICAL PRINCIPLES

GMA Panels with double busbar

17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee

High Integrity Pressure Protection System

Root Cause Analysis Report Tesoro Golden Eagle Refinery Refinery Power Outage

MXSU - Selection table 3-core Kits / X-section

EE034: Electrical Maintenance for Engineers & Technicians

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

Substation Monitoring System

We can help you with the Fire Risk Assessment. What s more, we can help you put your evacuation plans in place.

Understanding and implementing an electrical safety regime in your organisation. Dispelling the myths and promoting a risk-based approach

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

THE QUICKEST WAY TO REMODEL YOUR KITCHEN

PRESENTS AQUADUCT AUTOMATED WATER-LEAK MONITORING SYSTEM A KINGPIN TECHNOLOGY

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

ABB Ability System 800xA Alarm Management

Multi-Technology Fault Identification

Guide to Gate Safety Legislation & the Machinery Directive

Dangerous Assumptions

THERMAL DIAGNOSIS OF MV SWITCHBOARDS: A COST-EFFECTIVE, DEPENDABLE SOLUTION BASED ON AN OPTICAL SENSOR

Using Infrared for Residential Energy Surveys

SEL Arc-Flash Solutions

GM Ultrasonic Gas Leak Detection Gas Detection at the Speed of Sound. How fast does your Gas Detection System detect leaks?

DoctorProAudio.com. U-Build It Enclosure Guide. UB4755 UB4770 UBSUB Horizontal Format Dual 12 + Compression Driver system. DoctorProAudio.

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

White Paper. OSHA and NFPA 70 Understanding NFPA 70 and its. Implications in Electrical Inspections Abstract: iriss.com

Power Consultancy for a Progressive Tomorrow

Air Compressor Electrical Fire

Arc Fault Protection System D1000

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

CCTV Surveillance: Business Security & Video Best Practices.

Guide to Gate Safety Legislation & the Machinery Directive. In Association with:

MRI Advanced Cooling System

COMPANY PROFILE Electrical & Instrumentation Contractor

Your computer system is the lifeblood of your business. Cyber threats are. what you hear most about today. Hacks, viruses and spyware get constant

F&G detection system for LNG plants

Risk Management Services. Electrical Safety Inspection and Testing. We can show you more.

6 things to consider. when designing your steri-center

Portable Washing Machine GPW-6

Effective Alarm Management for Dynamic and Vessel Control Systems

New requirements for IEC best practice compliance

Testing of (E)HV extruded cable systems, a necessary step to achieve system reliability

AE R1 October to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors

Work involving High Voltage (HV) Systems and Maintenance of Plant.

:: Sleeve styles :: There are three main types of crimp sleeve in common use. 1. Round section 2. Oval section 3. Double barrel

INTRODUCTION TAQQAT Global Co. Abdulla Fouad Group

Transformer On-Line Monitoring

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

OPUCN CUSTOM INCENTIVE RATE PLAN PERFORMANCE REPORT

Machine Guard Safety. Leader s Guide and Quiz

INCREASING SAFETY THROUGH THE INTRODUCTION OF AN ELECTRONICALLY-BASED CENTRALIZED BLASTING SYSTEM. P J Laubscher DetNet South Africa

CAP Series ,,,,, The Clear Choice. CAP Series Features: Who Says Infrared Windows Have to be Round? Certifications:

NFEC FIRE SAFETY SEMINAR Krish Mysore

Leak Detection and Water Loss Control. Maine Water Utilities September 9, 2010

User Detection Sensors

Transcription:

CONTINUOUS MONITORING IS ON THE RISE: CAN YOU ADAPT? BY WILLIAM HIGINBOTHAM, EA Technology LLC Electrical testing companies have traditionally built their businesses by periodically running tests on electrical assets. This reassures the end user that their equipment is in good working order and hopefully will remain that way until the next scheduled test. However, that isn t always the case, and failures can occur between tests. Given the high impact of failures and aging of medium-voltage assets, as well as the growing number of options in cost-effective monitoring solutions, a change is taking place: End users are increasingly installing 24/7 monitoring on their mediumand high-voltage assets. Potential problems are spotted when they start and are more likely rectified before failure occurs. Cost-effective monitoring systems and services for thermal increase and partial discharge (PD) are readily available. Thermal monitoring checks the health of your conductors and can replace periodic infrared scans while reducing the need for visual inspections. PD monitoring checks the health of your insulation and can replace periodic PD surveys. Test companies that rely on thermographic and PD surveying of MV and HV equipment but do not adapt to this change may suffer in the coming years. An end user who buys a 24/7 monitoring system needs less periodic testing, thereby reducing the business available to testing companies. Testing companies that adapt and offer to install and maintain monitoring systems as well as react to monitor-generated alarms could see their business increase. It is important to understand this paradigm shift and plan accordingly to ensure the success of your testing company. WHY ISN T PERIODIC TESTING ADEQUATE? Periodic testing is certainly better than no testing, but it isn t perfect. Serious loss can occur if an undetected problem reaches catastrophic failure in the period between surveys. Obviously, if you test more frequently, the chance of failure goes down. However, at some point, that becomes too labor intensive and financially onerous. 48 FALL 2018

The obvious analogy is the increasing use of 24/7 wearable EKG monitors for heart patients. Having an EKG at your annual physical is great, but you can still have an issue between visits. For most people, the inconvenience and cost of such a device makes it not worth the benefit, but as cost goes down and convenience goes up, who knows? For high-risk patients, it can be a lifesaver. On assets above 2.5 kv, partial discharge testing is typically done annually or biannually because the general belief is that PD takes at least that long to lead to failure. That is sometimes or even often true, but it is not always the case. Take the following incidents as examples. Example 1: Distribution Utility In November 2014, a UK utility installed a fulltime-only partial discharge monitor at one of their high-risk substations. The site was judged high risk due to its location near a river s edge combined with the type of switchgear operated at the location. Tragically, there was no remote communication channel available, and the system data was not reviewed during the testing period. On July 28, 2015, the switchgear failed catastrophically (Figure 1). Experts reviewed the recorded data and found that the substation had read little to no activity from installation in November 2014 until March 2015. However, from March 2015 on, there was a marked increase in PD activity. Over a week-long period, PD rose to a level that had the alarm system been installed would have triggered an alarm Figure 1: Result of Inaction Catastrophic Failure (Figure 2). This spike continued to exist until July 28, 2015, when the switchgear suffered a catastrophic failure. Although a periodic survey in early March would have found no issues, a catastrophic failure still occurred four months later. This would have been easily detected with continuous monitoring. As a direct result of downtime, the utility received Customer Minutes Lost (CML) and Customer Interruption (CI) fines totaling $700,000. Figure 2: Dramatic Rise in PD Reading NETAWORLD 49

Example 2: Petro-Chemical Plant A large manufacturing site that is home to an olefin and polymers business and a crude oil refinery operates a combined heat and power plant that supplies electricity to the site through two separate 1km-long, XLPE cable circuits known as CHP1 and CHP2. Following the detection of partial discharge in three relatively new joint pairs during routine conventional offline very-low-frequency (VLF) testing, an on-line permanent cable monitoring system was installed. Following installation, the PD activity identified during the VLF testing was confirmed in all three cables and located to the vicinity of the suspect joint pairs. This removed the need to take the CHP plant off line again to perform further periodic VLF testing to determine the severity of the problem. Avoiding just a single CHP outage in this way saved more money in terms of lost production than the entire cost of installation. The onset of PD can be seen in Figure 3 for cable CHP2-R2 over a one-month period when levels rose from 100 pc to 1,000 pc. Figure 4 shows the very clean PD pulse that enabled location of the PD. This highlights the benefit of continuous monitoring whereby trends in activity can be seen that would have been missed with spot measurements alone. All three cables where PD was identified were successfully managed until their joint pairs were replaced during the planned outage 10 months later. The suspect joint pairs were sent for forensic examination. Heatshrink Figure 3: Rapid Increase in PD in CHP2-R2 Stress Control Sleeve Figure 4: PD Current Pulse Recorded on CHP-R2 Figure 5: Partial Discharge Location 50 FALL 2018

During the forensic investigation, evidence of PD was found in one joint of the joint pairs when the outer heatshrink cover was removed from the cable stress control sleeve (Figure 5). The root cause was identified as an incorrect gap only 1 mm instead of the recommended 5 mm between the XLPE insulation and the connector. This prevented the yellow mastic from filling the gap properly, leaving a void that led to the elevated electrical stress responsible for the detected PD. Example 3: Critical Infrastructure Building in Virginia A large office building had full-time partial discharge monitoring installed due to the critical nature of its operations. Ultrasonic and TEV detection were provided for all cable termination compartments. An installation mistake common to all the potential transformer cables (Figure 6) caused partial discharge to be present almost immediately upon energization. As seen in Figure 7, the cable was energized in early March 2017, and within a month, the ultrasonic level was already four times higher than other identical cabinets where the problem was previously corrected. During the next three months, the level increased to over 100 times that of the good cabinets. Figure 6: Improperly Installed PT Cables The cable was denergized after a few months, and the damage was similar to that shown in Figure 8. This image is from another cable that was previously damaged and replaced. Figure 8: PD Damage to PT Cable Figure 7: Graph Showing Marked Increase in PD Signature NETAWORLD 51

DOES THIS MEAN PERIODIC SURVEYING IS DEAD? Periodic testing is powerful and inexpensive, so it will take a lot to kill it. For assets below 2.5KV, periodic testing will always be more cost effective. Even for medium-voltage systems, it is the cheapest way to go. When asset owners look seriously at the cost of outages and aging infrastructure, lowest testing cost shouldn t be the only consideration. Each asset failure has an impact, and the owner should do a risk and impact analysis before deciding what to do. For most applications, a mix of full-time monitoring on critical assets and periodic surveying on less critical systems will be the ideal route going forward. WHAT S INVOLVED IN FULL-TIME MONITORING? Full-time monitoring systems roughly fall into one of two categories: invasive and noninvasive. Invasive systems require full shutdown and internal access to the cubicles. They are typically hardwired with sensors like coupling capacitors. These are capacitor dividers that are connected between the conductors and ground and have a test cable connection port. High-voltage (HV) wiring is required between the sensor and HV conductors. Low-voltage (LV) wiring is required between the sensor port and the electronics portion. A Hipot test is required after installation and before energization. Invasive systems are almost always permanently installed at the same time as the original system due to the work required to remove and relocate them. Non-invasive monitor systems use the same technologies as handheld non-invasive test devices. These include ultrasonic detection and Transient Earth Voltage (TEV). The main advantage of these systems is that they can be installed on the outside of switchgear and do not require outages. Cable monitoring can be added to either system, but it does require access to the ground straps of the cables. Because of its ease of installation, non-invasive monitors can be removed and relocated periodically. Either type of system can provide local or remote access. Local access is easier to install but does not provide instant response to emerging faults. Remote access with continual monitoring provides the additional advantage of allowing experts to analyze the data. The end customer (or the service company) does not need partial discharge expertise. Going back to the wearable EKG monitor, would you rather try to interpret the charts yourself or have the data continuously streamed to the hospital where a doctor can analyze it? WHERE DO TESTING COMPANIES FIT IN? As MV asset owners make the inevitable move to more continuous testing, less periodic testing will be required. Additionally, if issues are caught before failure, fewer large repairs will be required. Testing companies that rely solely on testing and repairing failed equipment will suffer from reduced opportunities. However, a testing company that evolves can still find plenty of opportunity. Designing, installing, and maintaining monitoring systems will be required. Responding to early indications of problems and making repairs in a timely fashion will increase as well. Testing companies would be well served to become familiar with monitoring systems and their installation and maintenance requirements. A popular use for monitors is employing portable systems for several months and then removing or moving to another set of assets. This is a viable intermediate step to permanently putting monitors on all assets. Testing companies may want to purchase portable monitor systems and provide the install, remove, and relocate services as well as leasing the equipment to the asset owners. 52 FALL 2018

One last gratuitous parallel reference to the 24/7 wearable EKG monitor: If they become inexpensive enough for everyone to have one implanted, and you are a medical technician who performs routine EKGs in a doctor s office, you might want to consider a new career. I hear jobs are opening in 24/7 PD monitoring. William G. Higinbotham has been President of EA Technology LLC since 2013. His responsibilities involve general management of the company, which includes EA Technology activities in North and South America. William is also responsible for sales, service, support, and training on partial discharge instruments and conditionbased asset management. He is the author or co-author of several industry papers. Previously, William was Vice President of RFL Electronics Inc. s Research and Development Engineering Group, where his responsibilities included new product development, manufacturing engineering, and technical support. He is a senior member of IEEE and is active in the IEEE Power Systems Relaying Committee. He has co-authored a number of IEEE standards in the field of power system protection and communications, and holds one patent in this area. William received his BS degree from Rutgers, the State University of New Jersey s School of Engineering, and worked in the biomedical engineering field for five years prior to joining RFL. Prevent Equipment Failures To prevent partial discharge related failures, Astute Monitoring Services, from EA Technology offers the combined benefits of permanent and regular monitoring of assets, along with expert analysis and reporting in one simple commercial arrangement. Switchgear Cables 24 x 7 Monitoring Online No upfront costs Expert analysis EA Technology LLC www.eatechnology.com 862.261.2759 sales@eatechnologyusa.com