Disc Type Steam Trap TSD-42

Similar documents
Steam Trap. Assist Trap Radiator Trap Radiator Valve

13-1. Temperature Regulator

Noiseless Heater Vacuum Relief Valve

Radiator Trap Radiator Valve

CD-33/CD-33S Controlled Disc Steam Traps

Pure Performance For Steam Mains and Tracers

Pure Performance For Steam Mains and Tracers

INSTALLATION, OPERATION

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

THERMOSTATIC STEAM TRAPS

Our Know-How. Your Peace of Mind. Steam Solutions

Why steam trap survey?

Liquid Drainers LIQUID DRAINERS

Series 1140 and 1141 Temperature Regulators

INSTALLATION, OPERATION

UNIVERSAL STYLE STEAM TRAPS WU450 Series

THERMODYNAMIC STEAM TRAPS

STEAM TRAPS

INSTALLATION, OPERATION

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

LIQUIDATOR UMT-TD Series Thermodynamic

MFP14 Automatic pumps. for condensate and other industrial fluids

Hydrocarbon & Chemical Processing Solutions

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA TRIM DESCRIPTION DESCRIPTION VALVE OPERATION. 82 ASTM A 216 WBC.

Hoffman Specialty General Catalog

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

MFP14 Automatic pumps for condensate and other industrial fluids

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

Economical and simplified solutions that offer quality and optimum steam trap service.

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

General Specifications

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

STAINLESS STEEL TRAP VALVE STATION

THERMODYNAMIC STEAM TRAPS

PRODUCTS. Expansion Joints Fire Fighting. Flexible Metal Hoses. Equipments. Insulation Solutions. Steam. Valves. Level Control.

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

THE THERMOSTATIC STEAM TRAP

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION

THERMODYNAMIC STEAM TRAP

LIQUIDATOR 450 SERIES

Steam Traps and Steam Specialties

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

Silhouette. Feedwater Heater. Boiler Feedwater

Inverted bucket steam traps Type OKZ PN6/PN16

C. B. Trading Corporation

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)

Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits

The right trap for the right application.

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

LHW HIGH HEAD DRAINAGE PUMPS

Inverted Bucket Steam Traps

STEAM TRAPS FOREST PRODUCTS LIBRARY FOREST RESEARCH LABORATORY OREGON STATE UNIVERSITY. Information Reviewed and Reaffirmed. August No.

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

High Capacity Instantaneous Steam Fired Water Heater

Pamphlet M JA3D / JA Series / G8 AIR & DRAIN TRAPS. TATSU2 SS1VG / JAHSeries

Water Fuel + Air for combustion Blowdown

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS (May 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Operating and installation instructions

PUMP. Horizontal Multi-Stage Pump. Type MS SERIES DIMENSION. Model MSL MSH (2 pole motor drive) APPLICATIONS companion flange (SS) Foot valve

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

Deluge Valves. Model 68 DE\ EL. Electrically Actuated Remote-Reset Deluge Valve. Dorot Fire Protection Division. Certification & compliance by design

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS3/SS5 SERIES. Manufacturer

TITAN FLOW CONTROL, INC.

Membrane Air Dryer. Dew point indicator. Fitting to exhaust purge air for dew point checker. Purge air discharge fitting for dehumidification

.2 Section Waste Management and Disposal..5 Section Performance Verification of Mechanical Piping Systems.

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

Model: 1100 Float-Controlled Condensate Trap, PN 25

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3

UL/FM Fire Protection Products Setting the Standard

Installation and Maintenance Manual Forbes Marshall Bucket Trap FMBT50

A complete, compact steam heat exchange solution for process and domestic water heating requirements.

A. This Section includes the following domestic water piping specialties:

AUTOTROL 360 MANUAL & 361 SEMI-AUTOMATIC FILTER VALVES SERVICE MANUAL

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

Packaged Steam Fired Water Heater

Honeywell Control Valve. HFP Asia Pacific

Scroll Water Cooled Chiller

Vacuum Saving Valve. ZP2V Series. With One-touch fitting type available!

Installation and Maintenance "L" and "LS" Series

Transcription:

Disc Type TSD-42 TSD-42 is disc type steam trap for high pressure (maximum pressure: 4.2 MPa). It is compact and lightweight, and can be installed horizontally or vertically. Disc Ring By-Metal Valve seat Screen Stable operation by air insulation It prevents no-load operation or steam leakage caused by influence of outside temperature. Excellent durability Disc and valve seat has superior durability thanks to stainless steel material processed by special heat treatment. Shortened warming up time By-Metal helps shortening warming up of steam equipment by solving air-binding and efficiently discharging cold water and air at startup. TSD-42 TSD-42 TD-10NA TD-30NA -7

TSD-7,7F Bucket Float Disc Bellows Bimetal Wafer By-pass Stainless steel Connector Right to Left Down to Up Up to Down Features 1. Four functions (STOP / BY-PASS / TRAP / TEST) can be switched easily with a spanner or monkey wrench. 2. The integrated bypass function helps reduce piping and construction work costs significantly. 3. Bimetal solves air-binding problem and ensures a smooth discharge of cold condensate or air at the start of operation, enabling steam equipment to efficiently start to run. 4. Can be checked without being affected by back pressure.. The stainless steel valve disc and valve seat are subjected to special heat treatment and very durable. 6. Equipped with a built-in strainer. 7. Can be installed vertically or horizontally as desired. 8. Rain cover is available as options for outdoor use. TSD-7F TSD-7 Specifications Model Application Working pressure Allowable back pressure Maximum temperature Installation posture Body Material Disc, seat Connection TSD-7 TSD-7F Steam condensate 0.03-1.0 MPa 0% of inlet pressure 183 C At any angle between vertical and horizotal (Do not put the cover under the horizontal level.) Ductile cast iron Stainless steel (special heat treatment) JIS Rc screwed JIS 10K FF flanged Maximum Continuous Discharge Capacity Chart W: Discharge capacity L/h 800 600 400 200 Nominal size 1A-2A 0 0 0.1 0.2 0.3 0.4 0. 0.6 0.7 0.8 0.9 1.0 P: Working differential pressure MPa The discharge capacity shown on the above chart is the maximum value. In designing a system, select a steam trap with a sufficient safety factor (four to five times the regular level). That is, for example, if a discharge capacity of 100 kg/h is required, select a steam trap capable of dischargeing 400 to 00 kg/h. -34

TSD-7, 7F Dimensions (mm) and Weights (kg) Hexagon 24 TSD-7 R 3/8 Nominal size d H Weight 1A 2A Rc 1/2 Rc 3/4 Rc 1 107 109 11 2. 2.6 2.7 Hexagon 24 R 3/8 TSD-7F Nominal size 1A 2A L 16 160 160 Weight 4.1 4.6.7 Option Genuine handle It can operate safely and easily switching. Rain cover It can effect on prevention of working blank shot from wet rain. -3

Switching Mechanism and Operation STOP BY-PASS TEST AP BY- TRAP PASS TR - S BY AS P AP BY- TRAP PASS TR - S BY AS P P O ST STOP Position TRAP STOP TEST ST TE ST TE TEST OP ST Trap Operation Bellows Strainer Outlet for testing Bypass Open Conventional piping Trap Open Open Close Open (Test line) Bypass pipe Steam Close Close Close All steam traps are set at the "STOP" position when delivered. Condensate 1. STOP: Fluid does not flow into the trap and out of the bypass because the inlet, the outlet, and the bypass are closed, and the strainer can be cleaned and the bellows can be inspected. 2. BY-PASS: Fluid flows through the bypass directly to the outlet. Select this position when blowing the piping during plumbing or discharging a large quantity of condensate before starting operation. Since fluid does not flow to the trap, the strainer can be cleaned and the bellows can be inspected. 3. TRAP: In this position, the steam trap performs regular trap operation, and condensate flows from the inlet to the outlet through the trap. It does not flow out of the bypass. 4. TEST: In this position, condensate is discharged from the inlet to the outlet for testing through the trap, and the operation of the trap can be checked. This check can be carried out with the outlet closed and without being affected by back pressure. Fluid does not flow out of the bypass. Precaution for Installation Piping Example 1. Carefully blow the piping before connecting the steam trap. 2. Connect the steam trap to the piping according to its arrow indicating the direction of flow. 3. Slope the piping and place the product at as a low position as possible in order to make condensate flow into the product by its own weight. 4. Do not insulate the piping inlet and the steam trap.. To install the product in a main steam pipe, provide a drip leg at the inlet side of the product. 6. Secure enough space for switching operation of the cock and maintenance (such as cleaning the strainer and inspection of the bellows). 7. If discharge capacity is not enough, install more than one trap. In this case, connect the traps to the piping so that their inlets are in the same level. 8. Do not install the steam trap in a place where ambient temperature is higher than the condensate to be discharged. End of pipe Main piping Drip leg Horizontal piping Lateral piping Vertical piping -36

TD-10NA,30NA Bucket Float Disc Bellows Bimetal Wafer By-pass Stainless steel Connector Right to Left Down to Up Up to Down Features 1. Bimetal solves air-binding problem and ensures a smooth discharge of cold condensate or air at the start of operation, enabling steam equipment to efficiently start to run. 2. The stainless steel valve disc and valve seat, which are subjected to special heat treatment, offers excellent durability. 3. The valve disc, valve seat and bimetal can be replaced on site without disconnecting the steam trap from the piping. 4. Easy maintenance and inspection due to simple structure: the valve disc is only movable part.. Compact, lightweight and inexpensive. Applicable in wide working pressure range and adjustment-free. 6. Installable in any direction and easy to plumb. 7. Free of improper operation and steam leakage due to air insulation type. 8. Built-in strainer eliminates requirement for strainer before the product. 9. Large discharge capacity. TD-30NA TD-10NA Specifications Model Nominal size Application Working pressure Allowable back pressure Max. temperature Connection Body Material Disc, seat TD-10NA 0.03-2.0 MPa JIS Rc screwed TD-30NA 1-2A Steam condensate 0.03-1.0 MPa 0% or less of inlet pressure 220 C JIS 10K FF flanged Ductile cast iron Stainless steel (special heat treatment) 0.03-2.0 MPa JIS 20K FF flanged -37

TD-10NA, 30NA Dimensions (mm) and Weights (kg) TD-10NA Nominal size 1A 2A d Rc 1/2 Rc 3/4 Rc 1 L 90 90 90 H 1 49 3 6 H 2. 60. 62. Weight 0.9 1.2 1.4 TD-30NA Nominal size 1A 2A L 12 140 10 H 1 1 4 6 H 2 9 63 63 Weight 2.3 3.4 4.1 The dimensions of the product with JIS 10K FF flanged and the product with JIS 20K FF flanged are identical. The thickness of JIS 10K FF flanges conforms to that of JIS 20K FF flanges. Maximum Continuous Discharge Capacity Chart W: Discharge capacity L/h 1200 1000 800 600 400 200 Nominal size 1A-2A Installation Posture * The steam trap can be installed horizontally, sidlingly, or vertically. 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 P: Working differential pressure MPa * The discharge capacity shown on the above chart is the maximum value. In designing a system, select a steam trap with a sufficient safety factor (four to five times the regular level). That is, for example, if a discharge capacity of 100 kg/h is required, select a steam trap capable of discharging 400 to 00 kg/h. -38

TSD-42 Bucket Float Disc Bellows Bimetal Wafer By-pass Stainless steel Connector Right to Left Down to Up Up to Down Features 1. Stainless steel used for main parts, making a contribution to improve corrosion resistance. 2. Since it can operate under 42 C temperature and 4.2 MPa pressure conditions, it can be applied in various types of industries, such as heavy, light, and general industries. 3. Bimetal solves air-binding problem and ensures a smooth discharge of cold condensate or air at the start of operation, enabling steam equipment to efficiently start to run. 4. ''Insulation cover'' avoids frequent on-off operation.. Plumbing is easy to perform because it can be installed vertically or horizontally as desired. 6. Built-in strainer eliminates requirement for strainer before the trap. Specifications Model Application Working pressure Allowable back pressure Maximum temperature Body Material Disc, seat Connection TSD-42 Steam condensate 0.03-4.2 MPa 0% or less of inlet pressure 42 C Stainless steel (SCS2A) Stainless steel (special heat treatment) JIS Rc, NPT, BSPT screwed Dimensions (mm) and Weights (kg) Nominal size L H H1 A Weight 10A 1A 2A 78 78 8 9 76 76 79 86 23 23 24 27. 32 32 38 4 0.6 0.6 0.7 0.9-39

TSD-42 Maximum Continuous Discharge Capacity 800 W: Discharge capacity L/h 700 600 00 400 300 200 100 Nominal size 1A-2A 0 0 0. 1 1. 2 2. 3 3. 4 4. P: Working differential pressure MPa To select the product size, secure the safety factor of 4 to. For example, if you need a steam trap with a capacity of 100 kg/h, the trap with a capacity of 400 to 00 kg/h should be selected for maximum efficiency. The back pressure (outlet pressure) should be considered in selecting discharge capacity. This is because discharge capacity of a trap depends on the operating differential pressure (the difference between the inlet and the outlet pressures). For example, to find the discharge capacity obtained by the inlet pressure is 1.0 MPa and the outlet pressure is 0.2 MPa, trace up from the point of the operating differential pressure of 0.8 MPa in the above chart. Installation Posture Horizontal Vertical -40