Skymen Cleaning Equipment Shenzhen Co., Ltd. Ultrasonic Cleaner Instruction Manual

Similar documents
Cavitator Ultrasonic Cleaner Instruction Manual Model 20G

Cavitator Ultrasonic Cleaner Instruction Manual

INSTRUCTION MANUAL. Model Number : CF-300K, CHEST FREEZER BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

PANEL RADIATOR. USER MANUAL HSDOnline.co.uk 2KW OIL FILLED POH04

Whittemore Ultrasonic Cleaner

CHEST FREEZER USER GUIDE LEC CF61LW

The Most Powerful Bench-top Ultrasonic Cleaner

INSTRUCTION SHOWER CABIN ILMA 901

OPERATIONAL & INSTRUCTION MANUAL. Models: 1000M, 1300M, 2000M and 2100M. (120v) UltraSonic LLC. P.O. Box Cincinnati, Ohio 45255

Thermoelectric wine cooler. Model No: UBWC450. Operation Manual

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

Cavitator Ultrasonic Cleaners

Cavitator Ultrasonic Cleaners

FagronLab NP-1 UV. Negative pressure workbench. User Manual

CHAPTER 1 SAFETY SUMMARY CHAPTER 2 MACHINE FAMILIARIZATION CHAPTER 3 UNPACKING AND INSTALLATION CHAPTER 4 OPERATION INSTRUCTION

FEATURES. Time set: 0~30 minutes digital timer; Temperature adjustable 20~80 digital control, Material: good quality stainless steel SUS304,

Turbo Sonic Raytech. Ultrasonic Cleaner. Operating Instructions

OPERATION INSTRUCTION

Operating Instructions

CHAPTER 1 SAFETY SUMMARY CHAPTER 2 MACHINE FAMILIARIZATION CHAPTER 3 UNPACKING AND INSTALLATION CHAPTER 4 OPERATION INSTRUCTION

4L Instant Water Boiler Instructions for Use

+ English + 1. Safety warnings

Intelligent Lead Free Soldering Station OPERATION and MAINTENANCE MANUAL

SPECIFICATIONS PART NAME

CONTENT. Precautions to Avoid Possible Exposure to Excessive Microwave Energy.. Important Safeguards... Control Panel...

16/11/218-V1 USER GUIDE ULTRA 2020 ULTRASONIC CLEANER

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

LCF Touch Modbus Datasheet Application Security Advice Caution

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

BRANSONIC Bransonic Baths

Manual Ultrasonic Cleaner PCE-UC Series

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX

Table of Contents. Notice: Any maintenance should be returned to the dealer or factory! Attention: Please read this instruction carefully before use.

15,000 BTU Portable Air Conditioner

Medical Refrigerator

G-10f/GCG-10f UPRIGHT COOLER

Ultrasonic Cleaner 13L. Instructions. ight Laser Tool. Laser

Bar Fridge USER MANUAL MB46W

INTRODUCTION UNPACKING & IMPORTANT 3-4 SAFETY INSTRUCTIONS SUGGESTED APPLICATIONS SONIC - D SERIES OPERATION INSTRUCTIONS 7-8 SONIC - MX SERIES 10-11

LCF Touch. Electronic Fan Coil Thermostat with Touch Display (Flush mounting) Datasheet. Application. Security Advice Caution.

Before digging into the 10 things you should know let s start with a brief explanation of the process.

1Byone Products Inc. USER MANUAL 400 Watt Low Lying Fog Machine Model No.: O00QL-0045

DOC JAN06 LT 200

USER MANUAL OF KL8300 SYSTEM

PRO SERIES IMPORTANT SAFETY INFORMATION

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

Operating Instructions

Operating Instructions

INSTALLATION AND OPERATION MANUAL

Superior Spa with Aqua-Aire

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

PORTABLE AIR CONDITIONER

TABLE OF CONTENTS FOR YOUR SAFETY

REFRIGERATED BATH CIRCULATOR. Instruction Manual. Covers model : LRBC-13C / LRBC-22C. Please read this manual carefully before using the instrument

HAWK SULTAN SERIES Sma rt Universa l Level Tra nsmitter And Network. Equipment types:

3KW ELECTRIC FAN HEATER

Oil Panel Heater Instructions for Use

DSSHP06G Intelligent Lead Free Soldering Station INSTRUCTION MANUAL

LED New Light Source Reflow Oven. Model: T-960

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

DOMESTIC STEAM GENERATOR Installation Instructions

Customized Industrial Products

DEUTSCH NEDERLANDS ENGLISH ESPAÑOL FRANÇAIS NR 350

Precision Ultrasonic Cleaning Equipment Buyers Guide

Antari Low Fog Machine

LCF Touch (from firmware version 1.7)

3. Thermal switch (70 o C thermostat) with a 3 m connection cable

Operating Instructions

Models: RP-10, RP-15, RP-20. User Manual

Conversion of Gazco Upgradable Controls to Battery Remote Control

Inverter Split-type Room Air Conditioner

BUILT-IN OVEN MODEL: EBO-D7080D(SS) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference.

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

USERS MANUAL FOR GAS BOILERS

Panel Fan Series Operators Manual (Galvanized and Polymer)

UL U TR LTRASONIC S ONIC SCALE ALER PIEZO MINI

Electric Salamander CHM-1200W CHM-2400W CHM-4350W. User s Manual

INSTRUCTION MANUAL FOR. Ultrasonic Cleaners AC-400H PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

- 1 - Updated on 18 March, 2010

2.8KW ELECTRIC FAN HEATER

STATIC ELIMINATOR I443A INSTRUCTION MANUAL

- 1 - Updated on 18 March, 2010

Parts introduction FRONT BACK

USER MANUAL. Content. XD W/250W Medical Cold Light source. ⅠBrief introduction...1

Instruction Manual for Bench-Top Cleaning Baths

PORTABLE AIR CONDITIONER

WATER BATH MODEL TBS451PA OPERATION MANUAL

MD-MINI Dry Bath. Instruction Manual

[FLARE CONNECTION TYPE] ATTENTION

Washing Machine OWNER S MANUAL TRWTL-70. Before using your washing machine, please read this manual carefully and keep it for future reference.

Local air conditioner

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

StatClean - Ultrasonic Cleaner

pure indoor living DIGITAL ULTRASONIC HUMIDIFIER MODEL: BU7500 INSTRUCTION MANUAL

SAVE THESE INSTRUCTIONS

Operation Manual PM-NIT-14006E

Transcription:

Skymen Cleaning Equipment Shenzhen Co., Ltd. Ultrasonic Cleaner Instruction Manual Model: JP-360ST and JP-300ST Please read the manual carefully before operation. 1

INDEX 1. Working conditions. 3 2. General.. 3 3. Structure & function... 4 4. Ultrasonic cleaning principle 6 5. Cautions. 7 6. Main parameters... 8 7. Instructions. 8 8. Maintenances 8 9. Trouble clearing.. 9 Figure (Structure diagram). 10 10. Warranty card..... 11 (The instruction manual suits for JP series ultrasonic cleaner) 2

Thanks for purchasing Skymen ultrasonic cleaner, the instruction manual note the necessary precautions during the installation and use, please read it carefully before operation and keep it for reference. Please ensure correct power and switch connect before starting the equipment. Be careful that the control panel will be corrosive under the condition of organic solution, strong acid and strong base. 1. Working Conditions Do not use the product under condition of : Where temperature fluctuate strongly Where it has high humidity and especially dew Where vibration or shock is strong Where corrosive gas or dust exist Where water, oil or chemicals splash. Where is easy to cause explosion. Machine Features: Ultrasonic power: 1800Wmax(360ST)/2400Wmax(480ST)/3000Wmax(600ST) /3600Wmax(720ST) Room temperature: -10 ~40 Room humidity: 2. General: 35~85 % Skymen JP series single tank ultrasonic cleaner are standard models in industrial field, 3

made of high quality SUS stainless steel plate, corrosion resistance and long lifespan, adopt with original South Korea ultrasonic transducer and advanced adhesive technology, high electro-acoustic conversion efficiency and strong ultrasonic power output. Equipped with automatic constant temperature heating device, heating range: room temperature~95. Skymen ultrasonic cleaner widely applied to industry of precision electronics, painting, semi-conductor, filter system, watch-clocks, glass, metal, jewelry, and medical instruments cleaning etc. 3. Str uctur e Function: Ultrasonic generator: output frequency is 40KHz (28/68/80/120/132KHZ are available for customized model).equipped with sweep function and compensation circuit, strong anti-interference ability, high output frequency precision. Transducer Convert electric power into Hi-Fi mechanical vibration energy, with broad band frequency, high power and high stability. Heating system: Automatic constant temperature heating systems, made up of heating panel, digital timer and temperature switch. Machine structure: below chart 1(on page 10) Timer: timer can be set by customer upon requirement 1-99hour Temperature: set temperature based on your demand, 20 ~ 80 can be setted. Ultrasonic control: A. ultrasonic tank: equipped with 40kHz 36-72pcs transducers. B. Ultrasonic tank: equipped with 4.5KW / 6KW/9KW/12KW heating tube. 4

C. Generator structure: Front view (Generator) 1. Current display: It shows working current or power of generator. 2. Power adjusting: adjust ultrasonic power by increasing power clockwise and decreasing power anti-clockwise, current changed accordingly. 3. Switch: it is generator power supply switch, switch on then generator starts to work. Back view (Generator) 1.Remote control: It will stop ultrasonic cleaning under uninterruptible power supply to protect the electronics wire 2: Parameters label 3.Fuse 4.Power socket: connect with 220V power 5. ultrasonic output: It is connection of generator and transducers. 5

6.Cooling fun: to cool the circuit board D. Operation panel: Temperature knob: set suitable temperature by clockwise and unclockwise. Heater ON: Heater working indicator, it turns red when heating system is working. Temp Reach: Heater indicator, it turns green when temperature reaches the setting number, heating system will stop working. Timer display: shows ultrasonic working time; Max working time is 99hours. Time can be set by hour or by minute. ON/OFF: Open or stop ultrasonic. Timer display Power off button Heater ON indicator Temp indicator light. It will auto on when temp reach set point. Temperature adjust knob 4. Ultrasonic cleaning principle: The ultrasonic cleaner uses transducers to generate sound waves; frequency is 28KHz or 40KHz. When the sound waves travel through the liquid, millions of tiny bubbles form 6

and burst continuously. This process is called a cavitation effect. The bursting bubbles scrub everywhere the liquid can penetrate. Intricate surfaces and difficult access areas, such as burs, endodontic files, serrated instrument handles, and hinged instruments, are cleaned more thoroughly and rapidly but no damage to cleaning objects. The cavitation is basic theory of ultrasonic. J P ser ies ultr asonic cleaner suits for aqueous solution, neutr al liquid is suggested. 5. Cautions befor e star t the machine: Place all buttons on OFF. Cleaning liquid is ready in tank, Empty tank working is forbidden! Don t let the liquid splash into the electronic parts, especially transducers. Start the ultrasonic when liquid temperature reaches we set. Don t start heating if no liquid or liquid level is lower than work level, or heating pad will be damaged. Don t contact the bottom directly (vibration plate), or may damage the transducers. Keep the machine in dry and cool environment. Generator power supply is 240V 50HZ and should be earthing. Cover the lid to reduce noise and attention to liquid drop and evaporation. Wash the tank if there is much deposit in the tank Don t pull inside liquid out if liquid temperature is not close to room temperature, to avoid the side tank which equip with heating tube deform. Don t move the machine when there is liquid inside tank to avoid splash. 7

Machine power supply is AC220V 50HZ must be grounded. 6. Main parameters: Type annotation: JP-600ST as example JP: Skymen standard series cleaner 600: 60pcs transducers ST: ultrasonic power adjusts series Model Tank size Ultrasonic Heating Ultrasonic Capacity Voltage power power frequency JP-360ST 600x500x450mm 1800W 4500W 40kHz 135L AC220V/50Hz JP-480ST 700x500x500mm 2400W 6000W 40kHz 175L AC220V/50Hz JP-600ST 800x600x550mm 3000W 9000W 40kHz 264L AC380V 3phase JP-720ST 1000x600x600mm 3600W 12000W 40kHz 360L AC380V 3phase 7. Instructions: Keep machine on the flat floor and must be grounded Connect power wire and ultrasonic cable correctly. Connect the drain pipe with factory drainage system Put into cleaning liquid to the working surface. Set temperature based on requirement and turn on the heater switch. Adjust ultrasonic power to Min., then start ultrasonic and adjust ultrasonic power to requirement after normal vibration. 8. Maintenance: Use high-pressure blast to clean dust of the control system regularly Clean the tank once a week at least 8

9. Trouble clear ing: Item Questions Possible reasons solutions remark A Power supply not connect Check and plug power switch B Fuse broken Check fitted power supply and fuse 1 No ultrasonic C Cable short circuit Connect fitted cable or replace a new D Transducer short circuit Inquiry our after service engineer E Other reasons Inquiry our after service engineer A Not strong ultrasonic cleaning Connect ultrasonic button and adjust B Too high too low liquid Adjust liquid into the best surface surface Adjust temperature into the most Suggestion 2 Not well cleaning C Too high too low temperature fitted 50-60 D Not suitable cleaning liquid Stop and switch off power supply, E Other reasons replace suitable liquid after the previous liquid cool down. Inquiry our after service engineer A Heating power switch bad Check heating plug to correct connect linkage Check outlet line with multimeter: B Fuse broken if OK and resistance value is few 3 No heating C Other reasons hundreds then replace fuse. Suggestion If not OK,it s short circuit, replace 50-60 heater. Inquiry our after service engineer 4 5 Temperature control failure Timer control failure A Thermostat loosen Fasten the thermostat header B Thermostat tube broken replace thermostat C Other reasons Inquiry our after service engineer A Timer knob out of control Loosen or tighten the screw B Timer failure Replace timer or digital panel C Other reasons Inquiry our after service engineer 6 Electric leakage 7 Other problems A Customer side not grounded To ensure grounded B Machine not grounded Check if machine earth wire loosen Inquiry our after service engineer 9

Structure diagram 10

10.Warranty card: Warranty card Skymen Ultrasonic Cleaner Model Out-of-factory Machine no. JP-360ST JP-480ST JP-600ST JP-720ST.. Working volt AC220~240V 50HZ AC380V 3phase Max power Ultrasonic frequency 7KW(360ST)/9KW(480ST)/12KW(600ST)/16KW(720ST) 28KHZ() 40KHZ() 68KHZ() 80KHZ() 120KHZ() Maintenances record Maintenance way Replaced parts P.I.C 01

02 03 04 05 06 07 08 09 10 11