Certificate of Compliance

Similar documents
Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

for CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN

Certification Supplement Manual

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certification Supplement Manual

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

ccsaus certificate: for GSI 127 Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title Page

Certification Supplement Manual

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

File E Project 97SC January 21, 1998 REPORT

Certificate of Compliance

Certificate of Compliance

Field Certification Certificate of Compliance

IECEx Certificate of Conformity

standards: standards:

Certificate of Compliance

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

INSTRUCTION & SERVICE MANUAL

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

Certificate of Compliance

MICROpeL 75 Combustible Gas Sensor Part Number: PM

IECEx Certificate of Conformity

An Urgent Bulletin from CSA Group

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

IECEx Certificate of Conformity

Guide for hazardous areas

IECEx Certificate of Conformity

INSTRUCTION MANUAL (ATEX / IECEx)

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

UL HAZARDOUS LOCATIONS SERVICES

INSTRUCTION MANUAL (ATEX / IECEx)

manual addendum DELPHI Ex

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

OPERATING AND INSTALLATION

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

IECEx Certificate of Conformity

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

OPTIBAR DP 7060 Supplementary Instructions

Explosion Proof Line Powered Telephone Ringer

Fact Sheet No.4. CompEx Modules EX01R to EX04R for Gas and Vapour Environments

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

Instruction Manual. CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications. 3 rd Edition 05/2007

User s Manual YTA610 and YTA710 NEPSI Certification

UL TEST REPORT AND PROCEDURE

SOUTH AFRICAN NATIONAL STANDARD

Explosion Proof Combination Signal db (A) / 5 Joule

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

Hazardous Area Zirconia Oxygen Systems

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Overview of Standards for CO Detection Products

INTERNATIONAL STANDARD

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection

UL TEST REPORT AND PROCEDURE

Approved by: Document no.: EGT

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

IECEx Certificate of Conform ity

Understanding Hazardous Locations Concepts

OPTIWAVE X500 Supplementary Instructions

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

Intrinsically Safe Transmitters, Option Code 2n

INTERNATIONAL STANDARD

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

Technical Specification VFD

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Gas meters - Conversion devices - Part 1: Volume conversion

Guide to Hazardous Location Approvals:

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

Report on the activities of the ATEX consultant. Xavier Lefebvre. Contract : CENELEC/NA Consultant/2013-1

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

Transcription:

FF02 Certificate of Compliance Certificate: 70068210 Issued to: Cascade Technologies Ltd Glendevon House, Castle Business Park, Stirling, Scotland. UNITED KINGDOM FK9 4TZ Attention: Mr M Douglas. The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US (indicating that products have been manufactured to the requirements of both Canadian and US Standards) or with adjacent indicator 'US' for US only or without either indicator for Canada only Issued by: B Spencer PRODUCTS CLASS 2258 02 - PROCESS CONTROL EQUIPMENT for Hazardous Locations CLASS 2258 82 - PROCESS CONTROL EQUIPMENT for Hazardous Locations - Certified to US Standards Marking (Class 2258-02) Class I Division 2 Groups B, C, D T4 Ex db IIB + H2 T4 Gb Tamb = -20 C to +55 C Type 3RX, IP66 DQD 507 Rev. 2016-02-18 Page 1

Marking (Class 2258-82) Class I Division 2 Groups B, C, D T4 Class I Zone 1 AEx db IIB + H2 T4 Gb Tamb = -20 C to +55 C Type 3RX IP66 Continuous Gas Analyzer, Model CT5800 110 V to 120 V, 60 Hz 220 V to 240 V, 50 Hz 1100 W max. Class 1 permanently connected fixed equipment OVC II PD3 External Maximum operating pressure of process gas: 1 bar(g) Temperature of process gas: +4⁰C to +60⁰C Conditions of Acceptability 1. The equipment has flameproof joints with dimensions which are other than those specified in Table 2 of ANSI/UL 60079-1: 6th Edition and Table 3 of CSA C22.2 60079-1:16. These flameproof joints are not intended to be repaired but where necessary the original manufacturer shall be contacted for guidance and information on the dimensions of the flameproof joints. 2. The fasteners which secure the cover are non-standard and shall therefore only be replaced by fasteners supplied by the manufacturer for this purpose. The fasteners must always be fitted with the washer supplied by the manufacturer. 3. The equipment has non-conductive surfaces which are a potential electrostatic charging hazard see the instructions for guidance. 4. The user shall ensure that the flow of process gas is limited to a maximum flow rate of 6 litres per minute. 5. The equipment shall only be used with process gases which are in gas groups B, C or D (Divisions) or IIB + H2 (Zones) and must not contain oxygen or any other oxidizer in concentrations greater than that found in normal air. 6. This assessment does not cover reliable function, performance, or other properties of the equipment not related to safety. 7. The equipment is to be installed using wire no larger than 1mm2 (18 AWG). 8. The equipment is only to be installed by manufacturer trained personnel. 9. If at any time there is a conflict between the system safety provisions and any relevant local (national or regional) requirements, the local requirements always take precedence. 10. The equipment is not to be used with flammable liquids. DQD 507 Rev. 2016-02-18 Page 2

APPLICABLE REQUIREMENTS CAN/CSA-C22.2 No. 61010-1-12 - Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use, Part 1: General Requirements UL Std. No. 61010-1 (3rd Edition) - Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use - Part 1: General Requirements CAN/CSA-C22.2 No. 0-10 (R2015) - Canadian Electrical Code, Part II - General requirements CAN/CSA-C22.2 No. 60079-0:15 - Electrical apparatus for explosive gas atmospheres- Part 0: General requirements CAN/CSA-C22.2 No. 60079-1:16 - Explosive Atmospheres Part 1: Equipment Protection by Flameproof Enclosures d ANSI/UL 60079-0: 6 th Edition - Electrical Apparatus for Explosive Gas Atmospheres - Part 0: Equipment - General Requirements ANSI/UL 60079-1: 6 th Edition - Explosive Atmospheres - Part 1: Equipment Protection by Flameproof Enclosures d CSA C22.2 No. 94.1-15 / UL50 - Enclosures for electrical equipment, non-environmental considerations CSA C22.2 No. 94.2-15 / UL50E Enclosures for Electrical Equipment, Environmental Considerations MARKINGS The manufacturer is required to apply the following markings: Products shall be marked with the markings specified by the particular product standard. Products certified for Canada shall have all Caution and Warning markings in both English and French. Additional bilingual markings not covered by the product standard(s) may be required by the Authorities Having Jurisdiction. It is the responsibility of the manufacturer to provide and apply these additional markings, where applicable, in accordance with the requirements of those authorities. The products listed are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US (indicating that products have been manufactured to the requirements of both Canadian and U.S. Standards) or with adjacent indicator 'US' for US only or without either indicator for Canada only. - CSA Monogram for Canada and US - Manufacturer s name: Cascade Technologies Ltd - Model number in accordance with the product section of this report - Certificate number: CSA 17.70068210X - Marking in accordance with the product section of this report DQD 507 Rev. 2016-02-18 Page 3

- Electrical Rating - Date of manufacture: Month and year of manufacture or date code. If a serial number is used instead of date of manufacture, a record of serial numbers shall be kept traceable to date of manufacture. (Not related to date of sale) - The protective earthing TERMINAL is identified by the IEC 60417 No 5019 symbol adjacent to the TERMINAL - Units provided with Laser shall comply with the marking and other requirements of IEC 60825 and of Canadian and U.S. federal regulations - The warning WARNING DO NOT OPEN WHEN ENERGISED (cast into the enclosure cover) - The warning WARNING - DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT - The warning WARNING POTENTIAL ELECTROSTATIC CHARGING HAZARD SEE INSTRUCTIONS - The warning WARNING - A SEAL SHALL BE INSTALLED WITHIN 50 mm OF THE ENCLOSURE DQD 507 Rev. 2016-02-18 Page 4

Supplement to Certificate of Compliance Certificate: 70068210 The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Project Date Description Product Certification History 70068210 2017-05-25 Original Certification. DQD 507 Rev. 2016-02-18 Page 1