mena s Globo series are a group of air conditioning products designed for markets where maximum ambient temperatures are not more than 43 C. These products are available in both cooling only and heatpump versions (in case of the wall mounted, the ducted and the floor-ceiling types). These series include the wall mounted, the cassette, the ducted,the floor-ceiling and the ceiling concealed split systems. Following are the product lineups. s : PC and VC s men s Globo series outdoor units with the capacity range from 9,000 48,000 have polymer casing which is corrosion-resistant ideal for sea coast application. For the 60,000 outdoor unit, the casing is made from high grade galvanized steel. Features Service-friendly design for ease of installation, service and maintenance. Factory pre-charged with refrigerant providing great convenience in installation. Powered by powerful and yet quiet and efficient rotary compressors in case of 9,000-36,000 BTU and scroll compressors for 48,000 and 60,000 Btu/Hr. Light weight,durable and corrosion-resistant, ideal for seaside installations in case of polymer outdoor unit. Controls and Their Features The controls for the wall mounted, the floor-ceiling are wireless types, but for the ducted units they are wired types. Follwoing are some of their interesting features : Dry-keep function for added comfort at sleep time. Twenty four-hour Timer On and Timer Off available. utomatic changeover function for the heat pump units. Multi-speed controls for flexible choices of comfort levels. uto-restart function when the power returns after a breakdown uto-air sweep incase of the wall mounted, the cassette, and the floor-ceiling units. ireless type remote controls for the X, SU and LC,SC models; wired controls for DNM and CM models. ireless Remote Control ired Remote Control
PC/X s : all Mounted Split System ir Conditioner mena wall mounted split system air conditioner has an indoor unit designed to be installed on the room wall for beauty and saving valuable floor space. It is very compact and light in weight. It s front fascia is quite trendy with modern flat fascia. Beside the 9,000-8,000 BTU/Hr range, mena wall mounted splits include the uniquely designed Jumbo wall mounted splits that cover the capacities from 36,000 BTU/hr - 48,000 BTU/hr with the ability to deliver an air discharge as far as metres. Following are key features of these products. Features Blue fins for hydrophilic property. High efficiency and quiet operation. Permanent anti-bacterial and antifungal filter and drain tray. Compact and light quite suitable for installation on the wall. nti-bacterial filters with nano copper, nano silver and activated charcoal (optional). Service-friendly construction facilitating disassembly for service without using any tooling. Super long air throw for fast air distribution and wide space coverage in case of 36,000 and 48,000 BTU unit.
PC/SU and VC/SU s : Floor-ceiling type Split System ir Conditioner This type of split system is also known as a universal or convertible split system air conditioner. This is so called because of its flexile installation applications, namely, on the floor, on a low wall or under the ceiling. The system is most adequate for shop houses, restaurants, schools, offices, canteens, bars,halls and so on. Here are some of its interesting features. Features ired or wireless electronic control capable. Built for ease of installation, service and maintenance. ide range of capacities catering to all cooling or heating needs. Elegant and attractive design blending well with modern interior decor. Versatile installations, namely, on a floor, on a low wall or under room ceiling. Multi-speed fan motor facilitating choices of air flow to suit each individual needs. PC/DNM and VC/DNM s : Ducted Split System ir Conditioner The indoor unit is built from high quality steels and electronically powder painted and baked for durability. It is designed especifically for easy installation and maintenance. This unit is suitable for a luxury house, a residence, a shop and light coercial installations where no obtrusive indoor unit sitting on the wall or hanging under the ceiling is unwelcome. Besides, the indoor unit is only 7 CM high (in case of DNM 8) and CM. (in case of DNM 4 to DNM 60). Here are some of the key features and benefits. Features High performance in cooling and heating. Low profile indoor unit fitting into most ceiling voids. Equipped with adequate devices for safe operation. vailable in both cooling only type and heat pump version. Five-speed indoor unit fan motor for multiple choices of optimal air flow. System is pre-charged with R- refrigerant to facilitate convenient installation. Indoor unit casing is fabricated from heavy gauge galvanized steel with oven baked electrostatic powder coating paint. Light-weight polymer outdoor unit casing for anti-corrosion and ease of transport (in case of PC8 PC 48 and steel casing for VC60.
X all Mounted Split System (T) R- (50HZ) Only Nominal Capacity Power Consumption Control Liq./Gas/Drain Max. Length L/hr EER X0MNVC-LPRZ X3MNVC-LPRZ X8MNVC-LPRZ X4MNVC-LPRZ XMNVC-LPRZ X36MNVC-LPRZ X48MNVC-LPRZ PC0RSVC-LRRZ PC3RSVC-LRRZ PC8RSVC-LRRZ PC4RSVC-LRRZ PCRSVC-LRRZ PC36RSVC-LRRZ PC48CSYC-LRRZ 9000 000 8000 00 8000 36000 6 3500 50 50 800 0550 0.33.7.74.3 3.94 3.89 4. 960 9.38 5.60 80 9.38 o6.4/9.5/od.6 o6.4/.7/od.6 5 +/-0 8.50 850 9.37.50 600 9.3 LCD ireless Remote Control. 90 9.59 o9.5/5.9/od.6 +/-5 7.0 3860 9.33 48000 0 5.6 380-/3/50 8.60 4950 9. X0MNVC-LPRZ X3MNVC-LPRZ X8MNVC-LPRZ X4MNVC-LPRZ XMNVC-LPRZ X36MNVC-LPRZ X48MNVC-LPRZ.7.3.3.7 Tube Cross Flow Motor 0. Sound Pressure Level at m. Unit Dimensions HxxD Packing Dimensions HxxD Net eight Gross eight Motor Tube Sound Pressure Level at m. Unit Dimensions HxxD Packing Dimensions HxxD Net eight /36/3/6 5 35 0 90 /37/33/7 35x84x 3x8x375 6 37 4 Gross eight capacity and electric characteristics are based on 7 C DB, 9 C B indoor temp. and 35 C outdoor temp. at highest speed. System is operative up to 43 C outdoor temp. 60 3 7 4 3 0 48//37/33 48/4/38/33 35x47x 3x00x375 6 7 6 0.x 4x 53/50/46/4 378x5x0 6 3 356x646x6 PC0RSVC-LRRZ PC3RSVC-LRRZ PC8RSVC-LRRZ PC4RSVC-LRRZ PCRSVC-LRRZ PC36RSVC-LRRZ PC48CSYC-LRRZ.38.5 0.38 0.6.5.66 7 6 380-/3/50 R- 0. 0.95..75.90.50 3. 5 660 500 0 48 60x869x35 5x93x3 755x035x378 8x48x3 7 0.x 48x 5 8 34
X all Mounted Split System (T) R- (50HZ) Heat Pump System Nominal Capacity Nominal Capacity Power Consumption Control Liq./Gas/Drain Max. Length L/hr EER COP X0MNVH-LPRZ X3MNVH-LPRZ X8MNVH-LPRZ X4MNVH-LPRZ XMNVH-LPRZ X36MNVH-LPRZ X48MNVH-LPRZ PC0RSVH-LRRZ PC3RSVH-LRRZ PC8RSVH-LRRZ PC4RSVH-LRRZ PCRSVH-LRRZ PC36RSVH-LRRZ PC48CSYH-LRRZ 9000 000 8000 00 8000 36000 48000 6 3500 50 800 0550 0 0000 500 8000 00 8000 38000 50000 9 3660 50 800 40 0.04 0.77.97.9 3.80 3.56 5. 4. 4.0 9 900 9.8. 5.50 5.00 0 50 9.84 0.87 o6.4/9.5/od.6 o6.4/.7/od.6 5 +/-0 8.60 7. 900 690 9.47 0. 380-/3/50.00.60 7.0 8.60 9.. 5. 8.00 480 900 3850 4980 00 0 3500 4600 9.7 9.66 9.35 9.64 0.95 0.37 0.86 0.87 LCD ireless Remote Control o9.5/5.9/od.6 +/-5 o.7/9.0/od.6 X0MNVH-LPRZ X3MNVH-LPRZ X8MNVH-LPRZ X4MNVH-LPRZ XMNVH-LPRZ X36MNVH-LPRZ X48MNVH-LPRZ.7.3.3.7 Tube Cross Flow Motor 0. Sound Pressure Level at m. Unit Dimensions HxxD Packing Dimensions HxxD Net eight Gross eight Motor Tube Sound Pressure Level at m. Unit Dimensions HxxD Packing Dimensions HxxD Net eight Gross eight /36/3/6 5 35 0 90 /37/33/7 35x84x 3x8x375 6 37 4 60 3 7 4 3 0 48//37/33 48/4/38/33 35x47x 3x00x375 6 7 6 0.x 4x 53/50/46/4 378x5x0 6 3 356x646x6 PC0RSVH-LRRZ PC3RSVH-LRRZ PC8RSVH-LRRZ PC4RSVH-LRRZ PCRSVH-LRRZ PC36RSVH-LRRZ PC48CSYH-LRRZ.38.5 0.38 0.6.5.66 7 6 380-/3/50 R- 0. 0.95.35.75.5.75 3. 5 660 500 0 48 60x869x35 5x93x3 755x035x378 8x48x3 7 * capacity and electric characteristics are based on 7 C DB, 9 C B indoor temp. and 35 C outdoor temp. at highest speed. System is operative up to 43 C outdoor temp. ** capacity and electric characteristics are based on 0 C DB indoor temp. and 7 C DB, 6 C B outdoor temp. at highest speed. System is operative down to -5 C outdoor temp. 0.x 48x 5 8 34
SU Floor & Ceiling Split System (T) R- (50HZ) Only Nominal Capacity Power Consumption Control Liq./Gas/Drain Max. Length L/hr EER SU3MNVC-LPRZ SU8MNVC-LPRZ SU4MNVC-LPRZ SUMNVC-LPRZ SU36MNVC-LPRZ SU48MNVC-LPRZ SU60MNVC-LPRZ PC3RSVC-LTRZ PC8RSVC-LTRZ PC4RSVC-LTRZ PCRSVC-LTRZ PC36RSVC-LTRZ PC48CSYC-LTRZ VC60CSYC-LTRZ 500 9500 00 000 36000 48000 60000 3660 50 8800 0550 0 7600 0.98.33..85.07 5.89 5.90 3 9.33 5 +/-0 9. 0 9.4. 5 9.34 4.00 0 9. LCD ireless Remote Control o9.5/5.9/od.6 +/-5 8.00 0 8.98. 380-/3/50 8.50 49 9.74 o.7/9.0/od.6 0.50 600 9.84 SU3MNVC-LPRZ SU8MNVC-LPRZ SU4MNVC-LPRZ SUMNVC-LPRZ SU36MNVC-LPRZ SU48MNVC-LPRZ SU60MNVC-LPRZ 3 Tube Double Intel Centrifugul 3 4 Motor 0.36..6.69.69x 7 93 3 00 00x 90 80 380 5 755 900 Sound Pressure Level at m. 43//37/34 48/46//4 53/49/47/4 54/5/49/47 55/54/49/47 55/54/53/5 Unit Dimensions HxxD 660x9x35 660x08x55 660x3x55 660x78x55 660x96x55 Packing Dimensions HxxD 748x94x36 748x048x36 748x34x36 748x8x36 748x946x36 Net eight 6 56 Gross eight 8 33 49 6 79 PC3RSVC-LTRZ PC8RSVC-LTRZ PC4RSVC-LTRZ PCRSVC-LTRZ PC36RSVC-LTRZ PC48CSYC-LTRZ VC60CSYC-LTRZ.38.5 Tube Motor Sound Pressure Level at m. Unit Dimensions Packing Dimensions Net eight HxxD HxxD 0.38 7 0.80 48 37 4 0.6.35. 5 660 60x869x35 5x93x3.5 R-.80.60 500 755x035x378 8x48x3 6 7.66 6 380-/3/50 Gross eight capacity and electric characteristics are based on 7 C DB, 9 C B indoor temp. and 35 C outdoor temp. at highest speed. System is operative up to 43 C outdoor temp. 3.35 3.60 0 64 975x90x334 036x058x 80 85
SU Floor & Ceiling Split System (T) R- (50HZ) Heat Pump System Nominal Capacity Nominal Capacity Power Consumption Control Liq./Gas/Drain Max. Length L/hr EER COP SU3MNVH-LPRZ SU8MNVH-LPRZ SU4MNVH-LPRZ SUMNVH-LPRZ SU36MNVH-LPRZ SU48MNVH-LPRZ SU60MNVH-LJRZ PC3RSVH-LTRZ 500 3660 00 3800 0.78 5.80 4.60 3 050 9.33.38 5 +/-0 PC8RSVH-LTRZ PC4RSVH-LTRZ PCRSVH-LTRZ PC36RSVH-LTRZ PC48CSYH-LTRZ VC60CSYH-LTRZ 9000 00 000 36000 48000 60000 55 8800 0550 0 7600 0000 5000 000 38000 48000 60000 5860 8800 0 7600.00.5.88.3.74 5.6 9. 7.90 00 9.05. 380-/3/50.60 4.0 8.0 8.60 9. 0.90 5. 7.60 60 4980 50 5 3480 0 9.0 9.3 8.9 9.64..8 0.9.7 LCD ireless Remote Control o9.5/5.9/od.6 +/-5 o.7/9.0/od.6 0. 8. 600 5 9.84. SU3MNVH-LPRZ SU8MNVH-LPRZ SU4MNVH-LPRZ SUMNVH-LPRZ SU36MNVH-LPRZ SU48MNVH-LPRZ SU60MNVH-LJRZ 3 Tube o9.53/grooved Double Intel Centrifugul 3 4 Motor 0.36..6.69.69x 7 93 3 00 00x 90 80 380 5 755 900 Sound Pressure Level at m. 43//37/34 48/46//4 53/49/47/4 54/5/49/47 55/54/49/47 55/54/53/5 Unit Dimensions HxxD 660x9x35 660x08x55 660x3x55 660x78x55 378x5x0 Packing Dimensions HxxD 748x94x36 748x048x36 748x34x36 748x8x36 356x646x6 Net eight 6 56 Gross eight 8 33 49 6 79 PC3RSVH-LTRZ PC8RSVH-LTRZ PC4RSVH-LTRZ PCRSVH-LTRZ PC36RSVH-LTRZ PC48CSYH-LTRZ VC60CSYH-LTRZ.38.5 Tube Motor Sound Pressure Level at m. Unit Dimensions Packing Dimensions Net eight Gross eight HxxD HxxD 0.38 7.0 48 37 4 0.6.35.60 5 660 60x869x35 5x93x3.5 R-.75.80 500 755x035x378 8x48x3 6 7.66 6 380-/3/50 3.35 3.60 0 64 975x90x334 036x058x 80 85 * capacity and electric characteristics are based on 7 C DB, 9 C B indoor temp. and 35 C outdoor temp. at highest speed. System is operative up to 43 C outdoor temp. ** capacity and electric characteristics are based on 0 C DB indoor temp. and 7 C DB, 6 C B outdoor temp. at highest speed. System is operative down to -5 C outdoor temp.
DNM Floor & Ceiling Split System (T) R- (50HZ) Only Nominal Capacity Power Consumption Control Liq./Gas/Drain Max. Length L/hr EER DNM8BNVC-LPRZ DNM4BNVC-LPRZ DNMBNVC-LPRZ DNM36BNVC-LPRZ DNM48BNVC-LPRZ DNM60BNVC-LJRZ PC8RSVC-LERZ PC4RSVC-LERZ PCRSVC-LERZ PC36RSVC-LERZ PC48CSYC-LERZ VC60CSYC-LERZ 0000 5000 000 36000 48000 60000 5850 7 8800 0550 0 7600.08.48..50. 4.80 9.50 00 9.5.0 0 9.33 4. 3 9.06 +/-5 8.00 0 8.98 ithout Control (ired Control is Optional) o9.5/5.9/od.6 8.60 5000 9.60 380-/3/50 o.7/9.0/od.6 0. 6000 0.00 Tube Motor Sound Pressure Level at m. Unit Dimensions Packing Dimensions Net eight Gross eight HxxD HxxD DNM8BNVC-LPRZ DNM4BNVC-LPRZ DNMBNVC-LPRZ DNM36BNVC-LPRZ DNM48BNVC-LPRZ DNM60BNVC-LJRZ 3 3 Double Intel Centrifugul.6.. 3.49 3 7 3 5 660 750 9 50/47//43 50/47/4/38 5/48/4/ 59/55/49/ x880x53 0x880x53 0x80x3 0x0x3 36x97x5 358x97x5 358x7x 358x49x 6 35 43 5 8 3 38 46 55 PC8RSVC-LERZ PC4RSVC-LERZ PCRSVC-LERZ PC36RSVC-LERZ PC48CSYC-LERZ VC60CSYC-LERZ.38.5 Tube Motor Sound Pressure Level at m. Unit Dimensions Packing Dimensions Net eight HxxD HxxD.35 5 0.6 60x869x35 5x93x3.55 660 Gross eight capacity and electric characteristics are based on 7 C DB, 9 C B indoor temp. and 35 C outdoor temp. at highest speed. System is operative up to 43 C outdoor temp..5 R-.80. 50 6 755x035x378 8x48x3 7.66 6 3.35 380-/3/50 0 3.60 64 975x90x334 036x058x 80 85
DNM Floor & Ceiling Split System (T) R- (50HZ) Heat Pump System DNM8BNVH-LPRZ DNM4BNVH-LPRZ DNMBNVH-LPRZ DNM36BNVH-LPRZ DNM48BNVH-LPRZ DNM60BNVH-LJRZ PC8RSVH-LERZ PC4RSVH-LERZ PCRSVH-LERZ PC36RSVH-LERZ PC48CSYH-LERZ VC60CSYH-LERZ 9000 5000 000 36000 48000 Nominal Capacity 500 5600 7 8800 0550 0 00 9000 5000 000 38000 48000 Nominal Capacity 60000 5600 7 880 0 7600 L/hr 0.76.47.69.5.36 4. 380-/3/50 9.50.0 4. 7.90 8.80 0. 8.00 9.90. 5.00 7. 9. Power Consumption 0 690 3 0 5000 0 0 60 0 30 5500 EER 9.8 9.9 9.06 8.98 9.60 9. COP.8..4.5.79 0.9 Control ithout Control (ired Control is Optional) Liq./Gas/Drain o9.5/5.9/od.6 o.7/9.0/od.6 Max. Length 5 +/-0 +/-5 DNM8BNVH-LPRZ DNM4BNVH-LPRZ DNMBNVH-LPRZ DNM36BNVH-LPRZ DNM48BNVH-LPRZ DNM60BNVH-LJRZ 3 3 Tube Double Intel Centrifugul Motor.6.. 3.49 3 7 3 (CFM) (890) 5 () 660 (5) 750 (585) 9 (990) Sound Pressure Level at m. 50/47//43 50/47/4/38 5/48/4/ 59/55/49/ Unit Dimensions HxxD x880x53 0x880x53 0x80x3 0x0x3 Packing Dimensions HxxD 36x97x5 358x97x5 358x7x 358x49x Net eight 6 35 43 5 Gross eight 8 3 38 46 55 PC8RSVH-LERZ PC4RSVH-LERZ PCRSVH-LERZ PC36RSVH-LERZ PC48CSYH-LERZ VC60CSYH-LERZ.38.5 Tube Motor Sound Pressure Level at m. Unit Dimensions Packing Dimensions Net eight Gross eight HxxD HxxD.35 5 0.6 60x869x35 5x93x3. 660.5 R-.80. 50 6 755x035x378 8x48x3 7.66 6 3.35 380-/3/50 0 3.60 64 975x90x334 036x058x 80 85 * capacity and electric characteristics are based on 7 C DB, 9 C B indoor temp. and 35 C outdoor temp. at highest speed. System is operative up to 43 C outdoor temp. ** capacity and electric characteristics are based on 0 C DB indoor temp. and 7 C DB, 6 C B outdoor temp. at highest speed. System is operative down to -5 C outdoor temp. Printed : May 0