System 800 Addressable Fire Detection & Alarm System

Similar documents
The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Xenex Conventional Fire Detection & Alarm System

Installation, Operating and Maintenance Manual

Excel-EN Conventional Fire Control Panel

OPERATION AND INSTALLATION MANUAL

Precept Marine Control Panel Application Guide

Conventional Fire Detection

Conventional Leaflets

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Sita200plus. 200detectors. Single loop analogue addressable System

Intelligent Security & Fire Ltd

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

The EN54 Part 2 and 4 Fire System

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

Fire Alarm Control Panel. System Maintenance and Log Book

Addressable and Conventional Fire Protection

user manual Document No , Revision 03 November 2015

Conventional Fire Alarm System 2014 V1.2

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Intelligent addressable fire alarm control panel

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

4 wire conventional alarm system

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Intelligent Security & Fire Ltd

FEC400 Series. Installation Manual

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

INFINITY 8 INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL

Document No Issue 4 user manual

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

The EN54 Part 2 & 4 Fire System

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

MINERVA MZX125 Digital Addressable Fire Detection System

The complete conventional fire warning system

General Routing Interface

ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS

Application, Installation, Operation & Maintenance Manual

one Operating instructions SenTRI ONE panel-based Fire detection and alarm system

Operating instructions Vigilon panel and Network node Fire detection and alarm system

The EN54 Part 2, 4 and 13 Fire System

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

SECURIT 700L PLUS ENGINEERING MANUAL

Fire detection and alarm system Operating instructions

Fire detection and alarm

RE 102 RE Fire Alarm Control Panel. Installation, Commissioning & Operating Manual

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

ID50series. intelligent fire alarm panels

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

C E R T I F I C AT LPCB I O N B O A R D P R E V E N T L O S S. Cooper Fire Systems

ZXSe Range Data Sheet

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

HG Home Guardian Advanced Home Energy, Safety and Security Management

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1

ZSC100 Gas Detection and Alarm System Controller

SALES SUPPORT DOCUMENT

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

Industries. As a premier global manufacturing company, we believe that great brands are

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

QA16 Addressable System

MINERVA MZX125. Digital Addressable Fire Detection System

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Control Panel User Guide

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

intelligent fire alarm ID60series panels

An introduction to... Sigma

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Intruder - Fire - Water Combined Alarm

EFBW series - BiWire Ultra control panel

Product Data Sheet. Remote Terminals. Features:

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Control Panel Engineering and Commissioning Instructions

Interface Modules for SENTRI

The new detector from Rafiki

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

SYSTEM 5000 USER MANUAL

Cooper Industries (UK) Ltd

2018 Johnson Controls. Tyco Fire & Security GmbH, Victor von Bruns-Strasse 21, 8212 Neuhausen am Rheinfall, Switzerland DUO-CEL

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Touch Screen 1 loop Addressable Fire Alarm Panel

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

CONVENTIONAL CONTROL PANEL FL2/4/8/12 LT-XP

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

Transcription:

SECTION 5: page 1 Section 5: System 800 Addressable Fire Detection & Alarm System

SECTION 5: page 3 10 reasons to specify 800 1 Plug and Play A user friendly panel not requiring special software tools to commission the system, providing true Plug and Play capability. Easy to use All data is entered via easy to use Form Fill menus as a guide through the data entry process, saving valuable commissioning time. 3 Flexibility A 1KM single loop with up to 127 addressable system devices gives the user flexibility to meet all the requirements of small to medium sized installations. Addressability at a conventional cost Conventional detectors teamed up with an addressable base, offers the benefit of an addressable system at an attractive cost. 5 Maintained integrity 24 zones of detection are supported and each device can short circuit handle, maintaining system integrity under fault conditions. Clear labelling Both zones and devices can have 32 character text labels. This gives devices meaningful descriptions, allowing fires or faults to be located quickly. 7 Cost savings Flexible alarm circuit configurations are possible and all sounder circuits are compatible with conventional electronic sounders and bells, giving the system designer the ability to choose the most cost effective solution. Supports other products Inputs from other systems such as an existing fire panel, manual call points or beam / flame detectors can be supported. Relay outputs are available for actioning plant shutdown in the event of a fire. 9 Extra features A host of other features are available such as class change, weekly fire test, sounder delay functions, coincidence detection and maintenance reminders triggered by the panel s real time clock. Compliance with the relevant industry standards GENT are LPCB approved for both systems and products and the 800 is designed to comply with EN 54.

SECTION 5: page 4 System Architecture Addressable Base with Conventional Detector MCP 24 Zone LED Repeat Panel 12V Sounder Controller LOCAL INPUT 240V Note: 1 Max. 127 devices per loop. 2 Maximum loop length is 1km. Fire/Fault Input unit 3 This schematic is for guidance only, please refer to product instructions during installation. 240V

SECTION 5: page 5 System 800 The System 800 single loop addressable control panel is an easy to use EN 54: Part 2 & 4 compliant panel. The System 800 panel is feature rich including a 1km loop, 24 zones, 127 devices, flexible sounder circuit design and input/ output facilities which allows the system designer to satisfy all the requirements of a fire alarm system in one easy to use package. 800 Control Panel TECHNICAL SPECIFICATION Mains Voltage 230 V/ 50-60 Hz 0 o C to +50 o C Loop Operating Voltage 9-19V dc Panel Quiescent Current Approximately 50mA Sounder Circuits 2 x 0.45A each 3.1 Kg (excluding batteries) IP31 Standby Period (fully loaded system) 72 hours + 30 minutes alarm load Relevant Standard EN 54 Parts 2&4 This provides small to medium sized buildings with a comprehensive fire protection system at an affordable price. Note: Cable entry is via the top of the panel using the 20mm knockouts or the back of the panel in the area indicated using the 20mm entry holes. Cable entry in this area top and back 375 Control Panel 788802 355 115 Less Batteries 788802-LB

SECTION 5: page 6 800 System Devices Detectors A standard range of LPCB approved conventional smoke and heat detectors are available for use with the detector base module. The removal of a detector from the base module is reported by the panel but does not affect the operation of any other devices on the loop. Smoke Detector 7800 SERIES SMOKE DETECTORS Nominal Voltage Range 9-28V dc Quiescent Current Optical 60µA Ionisation 30µA IP30 0.11 Kg -10 o C to + 50 o C Approval LPCB approved to EN 54-7 104 dia x 50 deep Heat Detector 7800 SERIES HEAT DETECTORS Nominal Voltage Range 9-28V dc Quiescent Current 20µA IP30 0.07 Kg -10 o C to + 50 o C Approval Fixed temp and rate of rise are LPCB approved to EN 54-5 Trigger Temperatures 104 dia x 50 deep Fixed Temp 58 o C Grade 1 Rate of Rise 58 o C Grade 1 High Temp 85 o C Range A SYSTEM 800 ADDRESSABLE DETECTOR BASE Quiescent Current 50µA IP30 Approximate Weight 0.07 Kg -10 o C to + 50 o C 104 dia x 21 deep Addressable Detector Base Optical Smoke Detector 17840-01 Ionisation Smoke Detector 17830-01 SOUNDER CONTROLLER Mains Voltage 230V/50 Hz Battery 2 x 12V 2.1 Ah Sounder Circuit 2 x 0.5A with 10K ohm monitoring resistor Aux Supply 24V @ 0.5A 3.3 Kg Housing Steel painted RAL 7024 317 W x 248 H x 83 D IP31 Dust Cover (50) 17890-02 Fixed Temperature Heat Detector 17850-01 Rate of Rise Heat Detector 17860-01 High Fixed Temperature Heat Detector 17870-01 Detector Base 781486 Detector Removal Tool 17918-30

SECTION 5: page 7 800 System Devices Call Points A standard break glass and key operated call point is available for use with the System 800 control panel. The key operated callpoint prevents unauthorised operation in areas with a high risk of tampering or vandalism. SYSTEM 800 MANUAL CALL POINTS Quiescent Current 45µA IP54 with gasket 0.17 Kg -20 o C to + 50 o C 88 sq x 50 deep Standard Call Point Call Point Accessories Pack of 10 test keys for testing call points without breaking the glass. Weather resistant kit, providing weather resistance to IP54. Pack of 10 spare glasses. LED Repeat Panel The repeat panel indicates which of the 20 zones are in a fire condition via individual LEDs which have positions for labels adjacent to each LED. Any fault and disablement conditions on the main panel are indicated by single LEDs on the repeat panel. The user is alerted to fire, fault and disablement condition via the integral buzzer which can be silenced locally. Key Operated Call Point 5 Door Holder LED Repat Panel 804792 Standard Call Point Key Operated 806120R-EN 806021R W/R Kit 14112-19 Spare Keys 14112-10 Spare Glasses 14112-09 Door Release 24V 04390-31 Door Release 240V 04390-55 Door Holder Floor Plate 04390-92 Door Plate Assembly (spare) 04390-99

SECTION 5: page 8 800 System Features System 800 Bell Shallow Base Sounder Single loop addressable 24 Zones 127 Devices per loop 32 Character device and zone Labels Short circuit isolators in each device Soft addressed on power up of the panel Max 1 km loop length based on 2 core fire rated 1,5 mm 2 cable 2 x 24V dc monitored master alarm outputs @ 0.45A each Auxiliary supply 24V dc 0.5A max 72 hr standby + 30 min alarm battery capacity Local monitored input for fire, class change and evacuate Auxiliary c/o contact rated 2A @ 30V dc configurable as: Common Fire (reset on Silence Alarms or Panel Reset) Common Fault Common Disablement Prefire Separate common fire output and common fault output contacts rated 2A @ 30V dc Delay/verify facility False alarm rejection facility Detector to detector coincidence Zone to zone coincidence Monitored manned centre link (MCL) output System labelled via keypad or software labelling tool Compatible with Gent 7800 conventional detector range System access levels all password protected Simple default One Out All Out configuration Weekly test reminder Maintenance due reminder One line of user defined text displayed on the panel Zone to sector output linking Relay Unit Bell 24V DC 12141-04 Sounder Deep Base 74452-24NM Sounder Shallow Base 74451-24NM Relay Units Boxed (for switching 230V) 19107-52