Nursing bench 3000, electrically height adjustable

Similar documents
R4952. SELECT wash basin lifter. Operation and maintenance manual

Ropox Swing Wash Basin. User Manual & Mounting Instructions / Fixed height with high wall unit. Keep this folder with product at all times!

Ropox Swing Wash Basin. User Manual & Mounting Instructions / Height adjustable with high wall unit

Ingenious bathroom solutions now and in the future

Ropox Bathtub. Keep this manual with the product at all times! User Manual & Mounting Instructions PDF 6128 /

Operating Manual 3 part Endoscopy Couch

Height-adjustable Unit

ELIOS 80 design Slide Studio

Instructions for use. Tango & Tango XL , Shower-toilet chair

FLUO 40 design SLIDE Studio

CARE & MAINTENANCE ALUMINIUM WINDOW & DOOR SYSTEMS BY

S-pod / ALTOR BATHROOMS MAINTENANCE NOTICE

GIOTTO 80 design Roberto Paoli

Operating Manual 3 part Multi Couch 2017

CUPOLE (80) design Giò Colonna Romano

CILINDRO 40 design SLIDE Studio

Operating Manual ECCO/ECG Couch

GLOBO 30 HANGING design SLIDE Studio

PIVOT design Carlo Costantini

INSTRUCTION MANUAL. operates with ISO9001 certified quality system. TECSYSTEM S.r.l Corsico (MI) Tel.: Fax:

User manual. Fjordblink Birth Pool and Water Supply Unit.

ACQUAGLOBO 30 design SLIDE Studio

X-POT / X-POT LIGHT (H33) design SLIDE Studio

LIGHTREE (H45) design Loetizia Censi

wc431 Slimline Integrated Dishwasher Manual for Installation, Use and Maintenance

owners manual mara washlounge #1408 MARA comfortel.com.au

KARCHERS POLISHERS OPERATOR MANUAL

INSTRUCTION MANUAL. operates with ISO9001 certified quality system. TECSYSTEM S.r.l Corsico (MI) Tel.: Fax:

Ctrl CTRL RAIL SYSTEM. Workspace tools and accessories that facilitate changing office environments, effortlessly.

Microbiological. Smart Safety Cabinet

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

Adam stool H50. Specifications. Toke Lauridsen. Design Year 2010 Typology Collection Origin Material Tops

GLOBO 30 design SLIDE Studio

MIRROR OF LOVE - S design Moro, Pigatti.

Finished Excellence. Limited Lifetime Finish Warranty. Armaturen.Accessoires.Interiors.Culture Projects.

PROTECTED INTEGRATED CUSTOMIZED

WATER BOILER METOS MARINE WKI MG MW,

INSTALLATION MANUAL GUTHD2. Universal Two Way Digital Thermostatic Valve for Shower Systems

PLATE DISPENSER MODEL NUMBERS MPN10000 MPN10500 MPN20000 MPN20500

PRODUCT CARE AND MAINTENANCE

Instructions for use Multibath

The Professional Choice

Cascade Comfort Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

ZEN MIRROR. Install / Operating Manual. Table of Contents

Operating Manual 4 part Multi Couch on Columns 2017

KORIKS-FIIBER. Pricelist Phone:

USER MANUAL LEEC CLASSIC INCUBATOR. C100, C157 and C330

GODMORGON & bathroom mixer taps

Composite Sinks Installation, Use and Maintenance

K 2 K 2, ,

K 2 Car. K 2 Car, ,

PRELUDE. User Manual. PA3500 Mattress Overlay System. Guarantees and Warranty. 1.1 General Information 1.2 Intended Use. 3.1 Unpacking 3.

The Professional Choice

Instruction Manual Model: IM03A

+ English + 1. Safety warnings

User manual Whirlpool

PEAK (H50 - Ø70) design Aksu, Suardi

K 2.98 M plus. K 2.98 M plus, ,

50L/D DEHUMIDIFIER. Model Number: IG9805 INSTRUCTIONS FOR USE

K 2 Premium Car & Home

FagronLab NP-1 UV. Negative pressure workbench. User Manual

HEAVY DUTY RANGE BAIN MARIES & HOTCUPBOARDS (ELECTRIC)

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

3m Cantilever Parasol Assembly Instructions Product size: Dia300*H245 cm

Slimline Dishwasher Instruction Manual

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

INSTALLATION AND MAINTENANCE MANUAL BLITZ FD_

User Manual for AirFlow Convection Oven

INSTRUCTIONS CertoClav EL

INSTRUCTION MANUAL SILHOUETTE SOFA. By GamFratesi

Artisan Thermostatic Bath Filler

Imperial Electric Fires

Umbrellas, Lighting & Weather Accessories

GAS SPIT ROASTING OVENS

CARRON PHOENIX Homecare Pack

ARRAY MODULAR FURNITURE Installation and Aftercare Instructions

User manual

Vanity Installation Instructions

SASE BULL 240C. Dust Collection System Manual

Invacare Propad. General. Cushion User Manual. General information. Warranty. Standards and regulations. Symbols in this user manual.

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

We recommend regular maintenance to keep your sink looking its best!

The aluminium and glass building products in your home have been supplied by Bradnam s Windows and Doors Pty Ltd.

SPECIFICATION, INSTALLATION AND OPERATION MANUAL UNDER BENCH GLASS WASHER EVO40ST

K K 2.120, ,

F A B G L A S S A N D M I R R O R

Owner Instructions Original Instructions Warning! Read instructions before using the machine

Product Aftercare Guide

Installation instructions. Built-in oven. and User guide NZ AU GB IE. OB60 single & double multifunction models

RONDA 2-58 Duo Heavy Duty Industrial Vacuum Cleaner For Liquid Filtration and Transport

JT-SB116JH-G-NA JT-SB116JH-W-NA

Care and maintenance instructions for products supplied by VEKSØ A/S

KOHLER Care and Cleaning Guide

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

Rota- Station and Plus Instructions

BEFORE USING THE COOKING HOB Page 9. SUGGESTIONS FOR ENVIRONMENT PROTECTION Page 9. PRECAUTIONS AND GENERAL ADVICE Page 9

K 3 Premium. K 3 Premium, ,

Floor Standing Bath Shower Mixer. Fitting instructions. Please keep these instructions for future reference and request of replacement parts.

VMS+ Cleaning and Disinfection Guide

Operation & maintenance information. for windows, doors and conservatories

Transcription:

Item number Colour Product description Adjustability Adjustment height Maximum load Speed without load Noise level Materials Ergonomy R8538021 VVS: 777540584 NRF:7501906 EAN:5708590275505 HMI: 46571 NBS:N13:40,375 Lead grey Nursing bench 3000, powered, height adjustable 700 mm; from 300 mm -1000 mm, with wired hand control Foldable. Incl. safety rail and water collection tray with integrated outlet. Surface length 1800 mm, outer measurements 1025 mm x 1910 mm. Excl. fixing kit. See Technical datasheet (pdf) for information on fixings suitable for various wall types. Height adjustable 700 mm Maximum load: 200 kg. When the bench is loaded with 200 kg, each mounting bolt supports 26 kg This product has been tested statically with a load of 500 kg as the IEC 60601- standard requires testing with safety factor 2.5. Speed up mm: 15 mm/s Speed down mm: 20 mm/s 48 db Aluminium, polyurethane foam, plastics, powder-laquered steel. Pressalit Care offers a range of high quality, fixed or power adjusted nursing benches designed to provide a stable platform suitable for changing adults and children in a variety of settings: schools, day care centres, institutions, hospitals and private homes. The nursing bench 3000 series provides for maximum safety and comfort. Besides an award winning design, the series includes comfortable and durable surfaces, including polyurethane foam and aluminum. The flexibility of the nursing bench provides for optimal working conditions for the carer as well as a high level of comfort and safety for the user.

Features Mains connection (V) Actuator (motor) Control box Wired remote control A water collection tray with integrated water outlet prevents water from splashing on carers or the floor. The flexible hose attached to the centre mounted outlet of the water collection tray, can be connected to either an outlet in the floor or on the wall. Adjustable neck support which can be moved to either end of the 1800 mm nursing benches. The slightly curved form makes the bench extremely comfortable and safe. The safety rail can be folded easily up or down. The integrated gas cylinders enable the bench to be folded out of the way when not in use to maximise floor space. 230 LA31 Careline, (Linak), 6000 N, IPX6 CB9 Careline, (Linak), IPX6 HB3 (Linak), IP66 Power usage Power consumption by maximum load: Power consumption by standby: 2 W 70 W Warranty Pressalit Care makes a commitment to remedy material and manufacturing defects for a period of three years from the invoicing date. NOTICE If the product is installed in an atmosphere heavy in salt or chloride, the warranty of the nursing bench will be reduced from the normal 3 years to 1 year. Salt and chloride have a corrosive effect on the products components and will cause a decrease in the life expectancy of the product. The damaging effects can, however, be reduced if the product is showered with tap water on a daily basis.

Cleaning Nursing benche 3000. The product is to be cleaned with hot water or a mild soapy cleaning agent. Do not use chlorine based, corrosive or abrasive cleaners as it may result in the surface being damaged. The following cleaning agents have been tested by Pressalit and may be used, as long as they are diluted according to the instructions on the container. DISINFECTANTS: Clinimax Difficil-S Erisan OXY+ Clinell Universal Wipes Clinel Sporidical Wipes Chlor-Clean Tablets WipeClean Ethanol Disinfection 80% Wetwipe Ethanol Disinfection 70% (wetwipe) NON-DISINFECTANTS: Wetwipe Universal The product must be wiped down with a soft rag wrung out in clear water immediately after cleaning, as some materials may otherwise be discolored and stained, and the surface coating may deteriorate. DECALCIFICATION OF ALUMINUM PARTS: Pressalit recommends that chalky deposits be removed from wall tracks and other aluminum parts using a solution of three parts 30% acetic acid to seven parts tap water. When the aluminum parts have been washed down with this solution, the parts must be wiped over with a damp cloth wrung out in clear water. WEEE CE Please enquire of your local Pressalit subsidiary or distributor (in countries where there is no subsidiary) that will arrange for recycling of electronic waste in accordance with the WEEE directive. This product complies with the requirements of Council Directive 93/42/EEC concerning medical devices, as last amended by Council Directive 2007/47/EC of 5 September 2007. It also complies with all relevant requirements in the Council Directive 2006/42/EC (of 17 May 2006) on machinery and the Council Directive 2011/65/EC on RoHS.

Installation in different wall types Concrete >B25 Solid Brick >= Mz12 Solid Sand Lime Brick >= Hlz12 Aerated Concrete P4 V8658 - Fixing kit, 6 coach screws Ø10 x 70 - plugs GB14. wood NB! Plugs are not needed.

22 mm plywood Wall fasteners (6 pcs) must be bought separately, for drywall it is possible to use e.g. fischer KD8 toggles or similar. steel plates (2 mm) Wall fasteners (6 pcs) must be bought separately, for drywall it is possible to use e.g. fischer KD8 toggles or similar. Drywall (2 x 12,5 mm) water-resistant Mounting in this wall type is not recommended - risk of fatal injury to persons and walls. It is the responsibility of the installer to ensure that suitable wall fasteners are used. www.pressalit.com Pressalit A/S Pressalitvej 1 DK-8680 Ry Tel.: +45 8788 8788 Fax: +45 8788 8789 E-mail: pressalit@pressalit.com