XLH210: controller for gas leak detectors

Similar documents
DEW POINT PROBES. with RS485 IN THIS ISSUE. PN 02 February 2009 DEW POINT PROBES. 1. Applications

POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS

CTT8 TEMPERATURE MONITOR DEVICE

CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Multi-Gas-Controller MGC2

XWA11V. Walk-In Temp / Door /Alarm / Light Module

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF:

Operating Instructions XWA11V XWA11V. Walk-In Temp / Door /Alarm / Light Module

XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

MO n : 12JMC rév A

EasyTronic III MANUAL SERVICE

Two-Channel Gas Controller

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

Dixell Installing and Operating Instructions release 7.0

Table of Contents. T538 Instruction Manual Rev # 6 June R6T538 June rtf E L Switchgear and Control Inc

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

GL-CO-RFG Channel Gas Leak Alarm System

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Operating Instructions XWA11V. XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Series Temperature Controller Instruction Sheet

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

Bottle cooler controllers Solutions for static, ventilated and open coolers

YOUR PARTNER IN FIRE & GAS DETECTION

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Dräger REGARD -1 Control System

Nov 08 PRODUCT SPECIFICATION SHEET

Gas Detection System TOX ALARM DG2000-Garage

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

HTC-915-CONT. Heat-Trace Control system

REFRIGERATED ROOM & TEMPERATURE/HUMIDITY CONTROLLERS

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

Chillgard Refrigerant Monitor

I/A Series 716C 1/16 DIN Temperature Controller

Temperature Controllers

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Fire Control Panel FS5100

Index. 1. General description of the application Types of units controlled Types of regulation Condensation...

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

APP 721 MODBUS Mapping

Intelligent addressable fire alarm control panel

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

Gas Controller Module GC-06

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Technical Speci fications 220V AC 50Hz or 110V AC 60Hz Accessories operational voltage. 2x 12V / 7Ah sealed lead acid gel batteries

Multiview Monitor / Controller

TraceNet ECM Series Control System

Process & TeMPerATUre UniversAl input DigiTAl MeTers

920 Series. A dry contact relay is provided for alarm annunciation back to a distributed control system (DCS).

LCF Touch Modbus Datasheet Application Security Advice Caution

M1000 Alarm Annunciator

Watchdog Elite Watchdog Elite BRAIME Product Information Bucket Elevator & Conveyor Hazard Monitor

ModBus DE-1 INSTALLATION AND USER MANUAL

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Technical Manual. Level Alarm Unit CARLA & WIDS

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM PRODUCT OVERVIEW

Specification for On-Line UPS Battery Monitoring and Data Management System

GS100M Gas Detection Controller

TER Active Room Temperature Sensor (Controller),

3M Oldham MX 43 Controller

TC300 Series Digital Fan Coil Thermostat

BX444-Mc Gas Detector

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

910 Series Single-point heat-tracing control system

F4 Process Controller Installation and Operation Guide

DiMM Unit. LST Digital Interface Monitor Module (LST-DiMM) MAN3109

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM

Variable Frequency Drive SERIES MP800 VFD

Dew point set DS 400

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

Installation, Operating and Maintenance Manual

REMOTE CONTROL FOR CHILLER MYCHILLER

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

Ammonia Leak Detector Manual

Flame Monitors BROCHURE

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

CODESEC FIRE ALARM SYSTEMS. security technologies

WaterLeakStop Manual. Detection and Management of Water Leaks WLS-1

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM. product overview

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

dixel Installing and Operating Instructions PRELIMINAY

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Catalogue 2015 AHU N Range: VENTUS VS 10 - VS 650

02/11/2015

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

Transcription:

pag. 1 / 7 XLH210: controller for gas leak detectors Dixell introduces the new digital controllers designed to be combined with 4 20mA gas leak detectors. XLH210 is a microprocessor based controller, designed to be combined with gas detectors, which enables the constant monitoring of the system and, in case of gas leakage, thanks to timely reporting, to intervene immediately to prevent system blocks and reduce the greenhouse gas emissions as required by international regulations. In addition to money saving, the safety aspect is guaranteed for people who are near the leak. This device has two alarm thresholds that can be adjusted on the display screen and recognized as Pre-Alarm and Alarm. XLH210 has a RS485 serial output with ModBUS-RTU protocol and can be monitored remotely via XWEB system.

pag. 2 / 7 1 MAIN APPLICATIONS XLH210 controller is used in all those refrigeration and air conditioning applications where it is necessary to detect possible gas leaks (a situation that is becoming increasingly felt and that in many cases is regulated by specific laws). Very appreciated is the possibility to remotly connect the device; for example the detector can be positioned within the cold room while the XLH210 controller can be placed outside in proximity of the door. 1.1 EXAMPLE: APPLICATION WITH GAS LEAK DETECTOR AND XLH210 Pre-Alarm Alarm

pag. 3 / 7 2 MAIN FEATURES 2.1 GAS DETECTION REPORTING XLH210 handles 2 alarm thresholds depending on the level of gas detected by the sensor. The user can check the status of the operation of the device thanks to the large LED display and the possible activation of the buzzer sound. During the operation, the display indicates the status of the device and the value, as a percentage, of any possible gas leak. If it exceeds the first Pre-Alarm threshold, the display will show the PAL message, the buzzer will sound intermittently and the corresponding relay activates; the user can temporarily disable the buzzer. If the Pre-alarm threshold drops below the defined value, the controller will automatically return into the standard operation. If the gas leak value increases, exceeding the Alarm threshold, the display will show the ALL message, the buzzer will activate with a continuous sound and the second relay will activate. Even in this case, the buzzer may be disabled temporarily. 2.2 USER INTERFACE The large double-digit display allows you to simultaneously monitor the status of the controller and the percentage of gas leak for a complete and immediate system control.

pag. 4 / 7 2.3 LIGHT ACTIVATION Thanks to the digital input and the related button, XLH210 allows the management of lighting; this feature is particularly appreciated because it allows to turn on/off the light directly at the room or in the affected environment. 2.4 GAS The managed gases depend on the type of detector used. Dixell recommends the use of sensors present in its catalog. For more information contact our sales department. 3 TECHNICAL DATA Housing: Self extinguishing ABS Power supply: 230Vac 50/60Hz ±10% Inputs: 4 20mA Digital inputs: Door switch, free voltage Connections: Screw terminal block 2,5mm 2 wiring Power absorption: 7VA max Data storing: On the non-volatile memory (EEPROM) Case: Frontal 210x230 mm; depth 87mm Protection: IP65 Display: higher with 3 digits, red LED lower with 3 digits, yellow LED Alarm 16A, 250Vac Relay outputs: Light 16A, 250Vac Pre-Alarm 8A, 250Vac Other outputs: Buzzer RS485 optional Kind of action: 1B Software Class: A Operating temperature: 0 60 C Storage temperature: -25 60 C Relative humidity: 20 85% no condensing

pag. 5 / 7 3.1 DIMENSIONS XLH210 can be mounted on a panel or on a wall for an easy disposal in any environment.

pag. 6 / 7 3.2 CONNECTIONS To each XLH210 only one gas leak detector can be connected; they can be networked and controlled by XWEB monitoring and supervising systems. Thanks to the digital output, it is possible to have a single siren for the entire system, thus reducing installation costs.

pag. 7 / 7 3.3 SUPERVISING XWEB EVO is the Dixell control and supervising system family that guarantees the remote monitoring of the XLH210 functionality and, consequently, of the plant. 4 HOW to ORDER XLH210 5 0 0 S E E RS485 0 NO 1 YES 5 PRICES Contact our sales department for prices, quotations and further information about gas detectors available in the catalog. 6 AVAILABILITY and ORDERS Models are available with standard delivery times.