1 Circulators high efficiency ECM Circulators

2 Circulators high efficiency ECM Circulators Small ECM circulators now available in North America Grundfos Alpha: Provides constant and proportional differential pressure and three fixed speed settings watt electrical input. Wilo Stratos ECO 16F: Provide constant and proportional differential pressure watt electrical input. Bell & Gossett ECOCIRC, Provides manual adjustable speed setting (VARIO model), and proportional differential pressure (AUTO model) watt electrical input. Taco Bumblebee Temperature based speed control watts electrical input Armstrong COMPASS Provides constant and proportional differential pressure and three fixed speed settings. 3-45watt electrical input.

3 Circulators high efficiency ECM Circulators Larger ECM circulators now available in US Wilo STRATOS circulators Grundfos MAGNA Taco Viridian Heads to 45 feet, flows to 345 gpm power inputs to 1600 watts B&G ECO XL

4 Circulators All these circulators rated A on the energy labeling system from Europump (European Association of Pump Manufacturers). high efficiency ECM Circulators European circulator rating system Single or multi-speed wet-rotor circulators like those commonly used in North America would be rated D or E on this scale.

5

6 Homerun distribution systems TRV TRV

7 The vast majority of hydronic distribution system developed in North America over decades were based on rigid piping. Bell & Gossett Circa 1949

8 PEX tubing was introduced in North America in the early 1980s, and was viewed primarily for use in radiant floor heating applications.

9 Slowly, some North American designers/installers began mixing PEX and PEX-AL-PEX tubing into system along with rigid tubing.

10 At this point, many North American heating pros recognize PEX or PEX-AL-PEX as a universal hydronic distribution pipe. One of the best approaches using this pipe is a homerun system.

11 Concept: Treat the tubing like electrical cable: If you can run an electrical cable from point A to point B within a building, you can also probably run a small diameter flexible tube set.

12 Examples of homerun distribution systems thermostatic operator air vent baseboard #6 ent towel warmer radiator baseboard #5 dual isolation valve TRV baseboard #4 baseboard #3 baseboard #2 pressure regulated! variable speed circulator PEX, or! PEX-AL-PEX tubing manifold station thermostatic radiator valves (TRV) baseboard #1 1/2" PEX-AL-PEX! tubing pressure regulated! circulator manifold station

13 Examples of homerun distribution systems differential pressure! bypass valve! (closed at design load) 24VAC valve actuators

14 A simple but elegant concept panel radiator TRV thermostatic radiator valves! on each panel radiator TRV TRV TRV TRV TRV pressure-regulated! variable speed circulator 1/2" PEX or PEX-AL-PEX tubing thermal storage tank manifold station + homerun piping thermostatic radiator valves pressure regulated circulator thermal heat source hydronics heaven

15

16 Hydronic Zoning Options

17 Hydronic Zoning Options A zone in an area of a building in which the temperature is controlled by a single thermostat, or other temperature sensing device. Two principal objectives of zoning: 1. Create desirable comfort conditions in various areas of a building 2. Reduce heating energy use by reducing space temperature when possible A zone can be as small as a single room, or as large as an entire building. The quality of a zoned system is not judged by the number of zones. Although itʼs possible to make every room its own zone, it is not often necessary, and can add considerable cost and complexity There is no absolute right way to zone a building. It depends on specifics of the building as well as occupant preferences:

18 Hydronic Zoning Options Zoning considerations: Areas with signifiant internal heat gain from sunlight, appliances, people or equipment, should be separate zones. Sleeping areas are often set up as separate zones from daytime activity areas. Areas of the building that are infrequently used should be separate zones. Garages, basements, exercise rooms, workshops are often separate zones Master bathrooms are often zoned separately to master bedrooms (cool bedrooms and warm bathrooms. The 2nd floor of a house is often zoned separately from 1st floor.

19 Hydronic Zoning Options Zoning considerations: Consider thermal mass of the heat emitters Donʼt combine high mass and low mass heat emitters on the same zone. mean slab temperature (ºF) medium mass! (1.5" concrete slab)! radiant floor panel high mass (6" concrete slab)! radiant floor panel 2400 sq. ft. slab on grade 60,000 Btu/hr! heat! input elaped time from first heat input (hours) indoor temperature ((ºF) room with lower thermal mass! and higher heat loss room with high thermal mass! and low heat loss Time from end of heat input (hours) T r = T o + [ T ri! T o ]e! " UA % $ 't # h & Where:! Tr = temperature of room (ºF)! To = outdoor temperature! Tri = initial temp. of room when heat input stops (ºF)! e = ! UA = heat loss coefficient of room (Btu/hr/ºF)! h = heat capacitance of room's thermal mass (Btu/ºF)! t = elapsed time without heat input (hr)

20 Hydronic Zoning Options Zoning considerations: Consider heat flow through interior partitions The low the heat loss of the building envelope, the more difficult it is to maintain interior temperature differences - especially if doors are left open.

21 Hydronic Zoning Options Methods of zoning 1. Zoning with on/off zone valves 2. Zoning with on/off manifold valve actuators 3. Zoning with on/off zone circulators 4. Zoning with wireless thermostatic radiator valves

22 go on SUPPLY side of circuit. Hydronic Zoning Options 1. Zoning with on/off zone valves Zone valves should go on SUPPLY side of circuit. Recommend 4-wire zone valves as most versatile. zone! valves fixed speed circulator differential! pressure! bypass valve VENT If a fixed speed circulator is used: 1. It should have a flat pump curve 2. the system should have a P bypass valve.

23 1. Zoning with on/off zone valves "flat" pump curve "steep" pump curve D 144!P = ( Head ) % ' & " $ # head large change in P " (undesireable) fixed speed circulator differential pressure bypass valve system curve (1 zone on) system curve (2 zones on) system curve (3 zones on) small change" in P (desireable) flow rate zone valves truncated pump curve (when DPBV is operating! above threshold setting) threshold P! setting of DPBV DHW D 144 % ' & pump! curve low flow resistance! common piping! CW!P = ( Head ) " $ # head indirect water heater flow rate (1 zone on) (2 zones on) system head loss curve (3 zones on) Design tip: Fixed speed circulator in combination with P bypass valves are on their way out. Modern systems will use ECM-based variable speed, pressure regulated circulators.

24 Hydronic Zoning Options 1. Zoning with on/off zone valves variable speed! (pressure regulated) circulator low flow resistance! common piping! zone valves head added / loss (feet) head added / loss (feet) system head loss curves (1) zone on perfectly flat pump curve (2) zones on (3) zones on flow rate (gpm) (4) pump curves decreasing circulator speed system head loss curves (1) zone on constant differential pressure control (2) zones on (3) zones on (4) flow rate (gpm) ! " # %! P =! H $ D & ! " # %! P =! H $ D & 144 Variable speed / pressure regulated circulator configured for constant differential pressure control. No DPBV used. Design tip: keep flow resistance of common piping as low as possible.

25 Hydronic Zoning Options L1 120 VAC N 1. Zoning with on/off zone valves high limit / switching relay control L1 relay! contact L2 C1 circulator Wiring a 4-wire zone valve C2 B1 B2 L1 120 VAC N relay! coil T burner external! 120/24 VAC! transformer T thermostat M 4-wire zone valve thermostat M 4-wire zone valve thermostat M 4-wire zone valve

26 Hydronic Zoning Options 2. Zoning with on/off manifold valve actuators high flow resistance heat source 24VAC thermostats! (1 per actuator) 24VAC to/from zones pressure! regulated! circulator! hydraulic! separator manifold! valve! actuators open indicator Manifold valve actuator wire identically to 4-wire zone valves. 2 wires for 24VAC power, 2 wires for isolated end switch. 3 VA (24VAC)! heating element return spring Select a transformer by adding the inrush VA rating of all actuators, plus 5 VA safety factor. 1/8" stroke M30x1.5 threads 2 leads for power, 2 leads for isolated end switch

27 VENT Hydronic Zoning Options 3. Zoning with on/off circulators Each circulator has internal check valve. 12 pipe diameters of straight pipe on inlet of all circulators. zone circulators! with internal! spring checks Circulators on supply, not return Low flow resistance heat source, and short/fatʼ headers provide hydraulic separation that prevents any significant interference of circulators. Use ECM circulators set for constant speed. low flow resistance! heat source

28 VENT Hydronic Zoning Options 3. Zoning with on/off circulators high flow resistance heat source spring-loaded! check valves zone circulators! hydraulic! separator If boiler has high flow resistance, use a means of hydraulic separation between boiler circuit and distribution circuit.

29 VENT Hydronic Zoning Options 3. Zoning with on/off circulators to / from zone loads high flow resistance heat source spring-loaded! check valves zone circulators temperature! sensor! (in well) ThermoCon! buffer tank low head loss headers If boiler has high flow resistance, use a means of hydraulic separation between boiler circuit and distribution circuit.

30 VENT Hydronic Zoning Options 3. Zoning with on/off circulators thermostats Use one of several available multi-zone relay centers to keep wiring organized. 120 VAC! input multi-zone! relay center low voltage wiring line voltage wiring 120 VAC normally-closed priority contact L1 N DHW tank! aquastat! (A1) room! thermostat! (T2) room! thermostat! (T3) room! thermostat! (T4) room! thermostat! (T5) room! thermostat! (T6) C2 C3 C4 C5 C6 zone circulators with check valves L1 N T1 T1 T2 T2 T3 T3 T4 T4 T5 T5 T6 T6 C1 X X C1 C1 C2 C2 C3 C3 C4 C4 C5 C5 C6 C6 to boiler! high limit control DHW! tank! thermostat C1 C2 C3 C4 C5 C6 zone circulators indirect DHW tank

31 Hydronic Zoning Options 4. Zoning with thermostatic radiator valves sealed pressure chamber opposing spring working fluid bellows setting knob setting indicator operator mounting collar removable cartridge valve spring spindle disc tailpiece 1/2 union valve body

32 Hydronic Zoning Options 4. Zoning with thermostatic radiator valves

33 Parting thoughts Plan ahead...

34 Parting thoughts Keep it neat...

35 Parting thoughts Keep it simple...

36 "Best Practices in Modern Hydronic Heating - AN OVERVIEW Thank you for attending today s session... Thanks also to the planning committee, and the sponsors of this session. Please visit our website for more information (publications & software) on hydronic systems:

The electrical wattage needed by the circulator is:

The electrical wattage needed by the circulator is: The electrical wattage needed by the circulator is: w e = 0.4344 f P n w/w A current-generation wet-rotor circulator has a maximum wire-towater efficiency in the range of 25 percent. If we put the data

More information

Distribution Efficiency: The Under-appreciated Benefit of Hydronics

Distribution Efficiency: The Under-appreciated Benefit of Hydronics International Centre, Mississauga, Ontario good craftsmanship, wrong approach Distribution Efficiency: The Under-appreciated Benefit of Hydronics Btu / hr presented by: John Siegenthaler, P.E. Appropriate

More information

Outdoor Reset Control Theory FULL versus PARTIAL reset

Outdoor Reset Control Theory FULL versus PARTIAL reset Outdoor Reset Control Theory FULL versus PARTIAL reset Conventional boilers must be protected against sustained operation at low temperatures. If not, they will be damaged by sustained flue gas condensation.

More information

"Best Practices in Modern Hydronic Heating - THE DETAILS

Best Practices in Modern Hydronic Heating - THE DETAILS "Best Practices in Modern Hydronic Heating - THE DETAILS 190 supply water temperature (ºF) 170 150 130 110 90 fin-tube convector (RR=1.38) panel radiator (RR=1.0) thin slab rad. floor (RR=0.69) slab r

More information

Hydraulic Separation Moving Beyond Priamry / Secondary Piping...

Hydraulic Separation Moving Beyond Priamry / Secondary Piping... Hydraulic Separation Moving Beyond Priamry / Secondary Piping... load! #1 load! #2 load! #3 primary! circulator presented by: John Siegenthaler, P.E. Appropriate Designs Holland Patent, NY www.hydronicpros.com

More information

Applications and Piping Strategies for Condensing Boilers - Introduction

Applications and Piping Strategies for Condensing Boilers - Introduction Applications and Piping Strategies for Condensing Boilers - Introduction Foil 2, 10/2015 Viessmann Manufacturing Applications and Piping Strategies for Condensing Boilers Webinar Objectives: 1. Control

More information

LOW TEMPERATURE HYDRONIC HEATING FOR COLD CLIMATES TRAVIS SMITH PRESIDENT T AND T MOUNTAIN BUILDERS INC

LOW TEMPERATURE HYDRONIC HEATING FOR COLD CLIMATES TRAVIS SMITH PRESIDENT T AND T MOUNTAIN BUILDERS INC LOW TEMPERATURE HYDRONIC HEATING FOR COLD CLIMATES TRAVIS SMITH PRESIDENT T AND T MOUNTAIN BUILDERS INC COLD CLIMATES REFERRING SPECIFICALLY TO CLIMATES ZONES 6 & 7 HYDRONIC HEATING USING A FLUID TO TRANSFER

More information

Hydronic Mechanical Panels

Hydronic Mechanical Panels Hydronic Assemblies Inc. 56 Horse Hill Rd Concord NH 2015-2016 Hydronic Mechanical Panels Contact 4805 Main St. Waitsfield, Vermont 05673 Phone : 802-583-5500 WWW.Houseneeds.com Hydronic Assemblies Inc.

More information

2.A MANIFOLD SHUNTS MINI SHUNTS

2.A MANIFOLD SHUNTS MINI SHUNTS 2.A MANIFOLD SHUNTS MINI SHUNTS ROTH HEATING SYSTEMS 2A. MANIFOLD SHUNTS Roth Manifold Shunts 4"/5.8cv and 1"/7.0cv Preassembled, manually adjusted, proportional temperature mixing station with built-in,

More information

Radiator Valve Program

Radiator Valve Program Radiator Valve Program Heat seeks cold faster when the temperature difference is greater. Lowering the temperature of a room reduces the amount of heat leaving the room (heat loss). Installing thermostats

More information

GETTING THE MOST OUT OF HYDRONIC HEATING SYSTEMS

GETTING THE MOST OUT OF HYDRONIC HEATING SYSTEMS GETTING THE MOST OUT OF HYDRONIC HEATING SYSTEMS Copyright 2011. R. Trethewey, All rights reserved. No part of this document or file may be used without permission of the author. All diagrams are conceptual

More information

6 PIPING ARRANGEMENTS

6 PIPING ARRANGEMENTS 6 PIPING ARRANGEMENTS The design of a panel radiator based heating system involves selection of a piping system, pipe sizes, overall design temperature drop, required flow rates and desired type of system

More information

Thermostatic Radiator Valves (Caleffi)

Thermostatic Radiator Valves (Caleffi) 02/09/16 B46 Thermostatic Radiator Valves (Caleffi) Thermostatic Control Heads Thermostatic control head fits radiator valves Set point locking mechanism Range stop adjustment Built-in sensor with liquid-filled

More information

Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS

Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS Comprehensive technology, energy-saving performance, plus compact professional design make HydroShark s modular panel

More information

know exactly what you are getting before you order it. You can order with confidence knowing th each panel is completely tested before it ships.

know exactly what you are getting before you order it. You can order with confidence knowing th each panel is completely tested before it ships. y y y Imagine know exactly what you are getting before you order it. You can order with confidence knowing th each panel is completely tested before it ships. Quick-ship panels are available for almost

More information

Technical Product Guide

Technical Product Guide FMU - Floor Mixing Unit Boxed set pre-assembled for immediate installation: The FMU Floor Mixing Unit integrates both temperature and flow management, making the single piece unit very easy to install,

More information

- Data Brochure Universal Reset Module 423

- Data Brochure Universal Reset Module 423 - Data Brochure Universal Reset Module 423 D 423 08/07 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in

More information

- Data Brochure Universal Reset Module 422

- Data Brochure Universal Reset Module 422 - Data Brochure Universal Reset Module 422 D 422 08/07 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in

More information

Air-to-Water Heat Pumps + Boilers A Dynamic Duo

Air-to-Water Heat Pumps + Boilers A Dynamic Duo Authored by John Siegenthaler September 2016 Edition Air-to-Water Heat Pumps + Boilers A Dynamic Duo Electrically powered heat pumps, available in many varieties, will play an increasingly important role

More information

Dear Hydronic Professional, edition. issue by ing us at ing to receive us future at

Dear Hydronic Professional, edition. issue by  ing us at  ing to receive us future at Caleffi North merica, Inc. Caleffi North merica, Inc. 9850 3883 South W. Milwaukee 54 th Street Rd Franklin, Milwaukee, WI 53132 Wisconsin 53208 T: T: 414.421.1000 414.238.2360 F: 414.421.2878 F: 414.238.2366

More information

ProRadiant Controls, Valves and Actuators

ProRadiant Controls, Valves and Actuators 214 Controls, Valves and Actuators Stock Controls, Valves and Actuators BASIC HEATING CONTROL Features: Modulating mixing valve control Supply temperature high limit Seasonal pump activation Boiler activation

More information

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE SPECIFICATIONS... 1 OVERVIEW... 2 PRECAUTIONS... 2 MOUNTING LOCATION... 2 CONNECTION TO BOILER PRIMARY PIPING:... 3 ELECTRICAL CONNECTION... 4 FLUSHING THE

More information

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve VENT APPENDIX A: PIPING SYMBOL LEGEND GENERIC COMPONENTS CALEFFI COMPONENTS circulator circulator w/ ThermoBloc union circulator w/ swing check spring loaded balancing balancing w/ gate check globe s purging

More information

Donʼt do this with ANY hydronic heat source! Heat transfer between the water and the upper floor surface is severely restricted!

Donʼt do this with ANY hydronic heat source! Heat transfer between the water and the upper floor surface is severely restricted! Donʼt do this with ANY hydronic heat source! Heat transfer between the water and the upper floor surface is severely restricted! Hydronic heat emitters options for low energy use houses Most CONVENTIONAL

More information

Application Guide. Vitodens 100-W B1HA/B1KA Residential Boiler

Application Guide. Vitodens 100-W B1HA/B1KA Residential Boiler Application Guide Vitodens 100-W B1HA/B1KA Residential Boiler APPLICATION GUIDE The application examples contained in this document serve as a guideline only. These are not engineered drawings and are

More information

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes. Introduction to Hydronics A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes. Hydronic heating systems use hot water or steam to deliver the

More information

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations Series 600 LFI / CFI Series 700 HFS Zone Control Stations Heating and Radiant Floor Zone Control Stations Installation Instructions Thank you for purchasing the finest in heating and radiant floor Control

More information

THE HEATING BOX. Training Manual. Model KD-HBO100 & KD-HBC100. * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System)

THE HEATING BOX. Training Manual. Model KD-HBO100 & KD-HBC100. * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System) THE HEATING BOX Training Manual Model KD-HBO100 & KD-HBC100 * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System) Automatic Hot Water Management System A Combination System for Domestic Water and

More information

Hydronic Solutions for Low Energy Houses

Hydronic Solutions for Low Energy Houses Hydronic Solutions for Low Energy Houses February 8, 2018 Burlington, VT Sponsored by: panel radiator TRV APPLIANCE! for space heating! and DHW presented by: John Siegenthaler, P.E. Appropriate Designs

More information

Wilo Stratos Z vs. standard three piece bronze domestic recirc pump

Wilo Stratos Z vs. standard three piece bronze domestic recirc pump Case Studies Wilo Stratos Z vs. standard three piece bronze domestic recirc pump This is a preliminary analysis of Wilo Z Domestic hot water recirculating pumps per our discussion last Tuesday. Following

More information

Boiler Demand Mix 1 Demand Mix 2 Demand DHW Demand Setpoint Demand

Boiler Demand Mix 1 Demand Mix 2 Demand DHW Demand Setpoint Demand Date Code - Data Brochure Universal Reset Control 374 D 374 10/03 The tekmar Universal Reset Control 374 is designed to maximize the comfort and effi ciency provided by a hydronic heating system. The control

More information

ECO1ZN3P, ECO2ZN4P ECO

ECO1ZN3P, ECO2ZN4P ECO WARNING HOT This product may have hot fluid circulating through it. DO NOT TOUCH! SOME UNION NUTS MAY BECOME LOOSE AND CONSEQUENTLY LEAK THROUGH TRANSPORTATION VIBRATION AND HANDLING. DO NOT OVERTIGHTEN

More information

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control. Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA 02717 The first totally integrated multiple boiler management control. USING THIS MANUAL USING THIS MANUAL A. INSTALLATION SEQUENCE Follow

More information

Panel Radiators. For Buderus Panel Radiator models: Applications Manual. - Model 21 - Model 22 - Towel Warmers

Panel Radiators. For Buderus Panel Radiator models: Applications Manual. - Model 21 - Model 22 - Towel Warmers s For Buderus models: - Model 21 - Model 22 - Towel Warmers 2 08.2014 Applications manual Table of Contents 1 General Info 5 2 Safety 6 3 Product Description 7 4 Mounting Guidelines 15 5 Radiator Output

More information

Radiant Heating. Systems

Radiant Heating. Systems O p t i m i z i n g t h e P e r f o r m a n c e o f Radiant Heating Systems Minimizing costly mistakes and maximizing a radiant project s performance by focusing on building and system efficiency Radiant

More information

Modular Panel System for Radiant Floor Heating.

Modular Panel System for Radiant Floor Heating. Modular Panel System for Radiant Floor Heating Comprehensive technology, energy-saving performance, plus compact professional design make HydroShark s modular panel system an easy install and a great value

More information

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS INSTALLATION AND OPERATING INSTRUCTIONS File No: 10.895 Date: march 8, 014 Supersedes: 10.895 Date: december 10, 013 1.0 Symbols used in this document 1.0

More information

Outdoor Reset IQ Option Card, p/n

Outdoor Reset IQ Option Card, p/n Outdoor Reset IQ Option Card, p/n 102723-01 Instruction Sheet CONTENTS Application... 1 General... 2 How it Works... 3 Installation.... 5 Wiring... 7 User Interface... 10 Using IQ Option Panel Display...

More information

Taco 00 Series Cartridge Circulators

Taco 00 Series Cartridge Circulators Water Circulation Pumps & Circulators Taco 00 Series Cartridge Circulators For over 70 years, Taco has led the industry with the highest quality circulators you can buy. Designed for a wide range of residential

More information

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money. How hydronic heating systems work

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money. How hydronic heating systems work EASY$ TIP SHEETS Energy Advice Saving Yukoners Money Quick Links How hydronic heating systems work Advantages Disadvantages Design alternatives Baseboard convectors Residential Hydronic Heating A residential

More information

Outdoor Reset IQ Option Card, p/n

Outdoor Reset IQ Option Card, p/n Outdoor Reset IQ Option Card, p/n 102723-01 Instruction Sheet CONTENTS Application... 1 General... 2 How it Works... 3 Installation.... 5 Wiring... 7 User Interface... 10 Using IQ Option Panel Display...

More information

Using ECM Smart Circulator Pumps in Primary Pump Applications in Hydronic Systems

Using ECM Smart Circulator Pumps in Primary Pump Applications in Hydronic Systems Monday, November 27, 2017 Using ECM Smart Circulator Pumps in Primary Pump Applications in Hydronic Systems Monday Morning Minutes by Norm Hall, November 27, 2017 Last week I featured the ECM High-Efficiency

More information

WM97+ Wall Mount Boiler

WM97+ Wall Mount Boiler WM97+ Wall Mount Boiler Questions & Answers Models 70, 110 & 155 INSTALLATION 1. Can the boiler be installed in a living area? Yes, the WM97+ is a wall mounted boiler. The sealed combustion and internal

More information

Daikin Altherma/Viessmann Integration Notes (used with schematics M1 thru M5)

Daikin Altherma/Viessmann Integration Notes (used with schematics M1 thru M5) March 15, 2011 Daikin Altherma/Viessmann Integration Notes (used with schematics M1 thru M5) Our Daikin Altherma project involves integrating an indoor unit (EKHBX054BA3VJU) with an existing domestic hot

More information

- Data Brochure Boiler Control 274

- Data Brochure Boiler Control 274 - Data Brochure Boiler Control 274 274_D 03/17 The Boiler Control 274 operates up to four on/off boilers to provide outdoor reset operation, domestic hot water and setpoint operation with priority. When

More information

- Data Brochure Steam Control 279

- Data Brochure Steam Control 279 - Data Brochure Steam Control 279 D 279 12/07 The tekmar Steam Control 279 can operate a single on-off steam boiler or an on-off steam valve using outdoor reset. The control determines the on time of the

More information

A Primary Concern by John Siegenthaler, P.E. October 1, 2005

A Primary Concern by John Siegenthaler, P.E. October 1, 2005 A Primary Concern by John Siegenthaler, P.E. October 1, 2005 When does a parallel primary loop make sense? It s hard to have a discussion on modern hydronic heating and not talk about primary/secondary

More information

Exploratory Lab Testing of a Residential-Scale Combined Space and Water Heating CO 2 Heat Pump

Exploratory Lab Testing of a Residential-Scale Combined Space and Water Heating CO 2 Heat Pump Exploratory Lab Testing of a Residential-Scale Combined Space and Water Heating CO 2 Heat Pump ACEEE Hot Water Forum 2017 Session 1B February 27 Ben Larson ben@ecotope.com Problem Statement(s) HFC refrigerants

More information

- Essay Control Functions and Benefits

- Essay Control Functions and Benefits - Essay Control Functions and Benefits E 005 07/01 A hydronic heating control system performs many complex and important functions. Each of these functions provide benefits that make the system comfortable,

More information

- Data Brochure Universal Reset Control 364

- Data Brochure Universal Reset Control 364 70 7 8 9 - Data Brochure Universal Reset Control 364 D 364 07/01 The Universal Reset Control 364 is designed to maximize the comfort and efficiency provided by a hydronic heating system. The control automatically

More information

Table of Contents. Installation, Operation, and Maintenance Manual V100 Series

Table of Contents. Installation, Operation, and Maintenance Manual V100 Series V101 EXPANSION TANK CONNECTION WARRANTY ON PUMPS VOID IF RUN DRY! CHECK VALVES INSTALLED IN ALL PUMPS WARNING HOT This product may have hot fluid circulating through it. DO NOT TOUCH! V10 EXPANSION TANK

More information

The Universal Reset Control 363 is a microprocessor based control designed to maximize the comfort and efficiency provided by a hydronic

The Universal Reset Control 363 is a microprocessor based control designed to maximize the comfort and efficiency provided by a hydronic R Vie Menu % % 1 2 Item F! WWS Vie Menu % % 1 2 Item F! WWS 70 LR 58233 E150539 Universal Reset Control 363 - Data Brochure D 363 12/08 The Universal Reset Control 363 is a microprocessor based control

More information

Radiant Pipe Description

Radiant Pipe Description Radiant Pipe Item Description ATIPXOB4C10 ATIPXOB4C250 ATIPXOB4C5 ATI Radiant Pex 1/2" x 1000' O2 barrier ATI Radiant Pex 1/2" x 250' with O2 barrier ATI Radiant Pex 1/2" x 500' with O2 barrier MPX836

More information

Grundfos is pleased to announce the sales release of many exciting new products.

Grundfos is pleased to announce the sales release of many exciting new products. GRUNDFOS BULLETIN Title: Sales Release Announcement Bulletin Number: DB-219-9-1 To: Grundfos Partners January 9, 219 Dear Partners, Grundfos is pleased to announce the sales release of many exciting new

More information

Hydronic & HVAC Control Systems

Hydronic & HVAC Control Systems tekmar 218 Full Line Catalog Hydronic & HVAC Control Systems HVAC Multi-Staging Alternative Energy Zoning Snow Melting Setpoint tekmarcontrols.com tekmarcontrols.com Better Design, Better Control, Better

More information

- Data Brochure D 260. Boiler Control /09

- Data Brochure D 260. Boiler Control /09 - Data Brochure Boiler Control 260 D 260 03/09 The Boiler Control 260 is designed to control a single stage heat source in order to provide outdoor reset or Domestic Hot Water () operation. The control

More information

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08 16/05/08 Aquatrol Indoor/Outdoor Control B3 Adjustable settings for boiler maximum temperature, boiler minimum temperature and outdoor low (design) temperature Selectable Warm Weather Shut Down (WWSD)

More information

Electro-HELPS XV ELECTRO-BOILER SPECIFICATIONS. A complete product line to fi t all your application needs. Made in USA

Electro-HELPS XV ELECTRO-BOILER SPECIFICATIONS. A complete product line to fi t all your application needs. Made in USA Electro-HELPS XV Made in USA ELECTRO-BOILER SPECIFICATIONS A complete product line to fi t all your application needs The Electro-Boiler has been heating America s homes and businesses since 980. We take

More information

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

1 DOCUMENT REVISION CONTROL ELEMENTS... 9 CONTENTS Contents 1 DOCUMENT REVISION... 8 2 SOFTWARE VERSION... 8 3 BASIC DESCRIPTION... 8 4 CONTROL ELEMENTS... 9 4.1 BASIC DISPLAYS...10 4.2 CONTROL KEYS...11 4.2.1 Rotary button (Press / Turn)...11

More information

Radiant Mixing Block

Radiant Mixing Block EFFECTIVE: arch 1, 2004 Taco Radiant ade Easy Application Guide Radiant ixing Block Products & Applications PA09 SUPERSEDES: New OVERVIEW Radiant ixing Block The Taco Radiant ixing Block (RB) is a complete

More information

Lowara ecocirc and ecocirc PREMIUM

Lowara ecocirc and ecocirc PREMIUM Lowara and PREMIUM THE REVOLUTIONARY HIGH EFFICIENCY CIRCULATORS FOR DOMESTIC HEATING WITH THE SIMPLE AND SHAFTLESS SPHERICAL MOTOR DESIGN AND PATENTED ANTI-BLOCK TECHNOLOGY How can efficiency work even

More information

Danfoss prefabricated floorheatingunit Type FH-G/FH-GS/FH-GR/FH-GRS

Danfoss prefabricated floorheatingunit Type FH-G/FH-GS/FH-GR/FH-GRS data sheet Danfoss prefabricated floorheatingunit Type FH-G/FH-GS//S Application The Danfoss prefabricated underfloorheating (UFH) unit for distribution of heating and domestic water is primarily designed

More information

11.4 Component Assembly Diagrams and Parts Lists Case Assembly

11.4 Component Assembly Diagrams and Parts Lists Case Assembly .4 Component Assembly Diagrams and Parts Lists.4.1 Case Assembly 1 5 4 6 7 8 70 Appendixes # Description Part # Remark 1 Intake Air Duct Assembly 000866B Exhaust Pipe Assembly 000867A Case 00775A 4 Intake

More information

caleffi hydronic valves page 1 of 12

caleffi hydronic valves page 1 of 12 caleffi hydronic valves page 1 of 12 page 2 of 12 MANUAL RADIATOR VALVES 1601811 - Series 340 1601812 - Series 341 1603748 - Seies 411 1603749 - Series 412 CONVERTIBLE RADIATOR VALVES 1601816 - Series

More information

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Reduced Installation time Precision regulation Minimal tooling required 100% tested prior to packaging High quality

More information

- Data Brochure Mixing Control 360

- Data Brochure Mixing Control 360 - Data Brochure Mixing Control 360 D 360 03/09 The Mixing Control 360 is designed to control the supply water temperature to a hydronic system in order to provide outdoor reset or setpoint operation. The

More information

Installation & Operation Manual

Installation & Operation Manual Boiler Control 275 Installation & Operation Manual Multi-Staging D 275 01/12 Replaces:03/09 The Boiler Control 275 is designed to stage up to four condensing or non-condensing, modulating or on-off boilers

More information

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA Instruction Sheet PC2 1 Two Stage Reset & Control SUPERSEDES : 102-106, dated June 1, 2000 EFFECTIVE: March 1, 2004 Plant ID# 9300-1059 Item 102-106 The PC2-1 is a microprocessor-based control designed

More information

ecocirc XL HIGH EFFICIENCY LARGE WET ROTOR PUMP FOR HEATING, COOLING AND POTABLE WATER SYSTEMS A-162C

ecocirc XL HIGH EFFICIENCY LARGE WET ROTOR PUMP FOR HEATING, COOLING AND POTABLE WATER SYSTEMS A-162C ecocirc XL HIGH EFFICIENCY LARGE WET ROTOR PUMP FOR HEATING, COOLING AND POTABLE WATER SYSTEMS A-162C Exactly what you need in a circulator As the industry leader with more HVAC and plumbing installations

More information

Control Application. Supplement - ACVMax

Control Application. Supplement - ACVMax prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

Parameter guide 95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER WARNING WARNING

Parameter guide 95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER WARNING WARNING 95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER! WARNING Revise boiler control parameters only if you fully understand the purpose and result of the changes and on the advice of ECR Technical

More information

CONTROLLED CHILLED BEAM PUMP MODULE

CONTROLLED CHILLED BEAM PUMP MODULE FIRST COST SAVINGS PROACTIVE CONTROL CONTROLLED CHILLED BEAM PUMP MODULE Active condensation control system effectively eliminates chilled beam condensation High efficiency, variable speed pump uses a

More information

Welcome To. System Benefits With ECM PUMPS

Welcome To. System Benefits With ECM PUMPS Welcome To System Benefits With ECM PUMPS Hydronic System Efficiency Should we be focusing on more than just the heat source? 2 The hydronic heating industry has put there main focus on the heat source

More information

Better Design, Better Control, Better Systems.

Better Design, Better Control, Better Systems. Product Catalog Better Design, Better Control, Better Systems. At tekmar Control Systems, we believe the indoor comfort of a building depends on the performance of its heating, ventilating & air conditioning

More information

- Application A Boiler Control 262 & One Stage Setpoint Control 150. Mechanical Remote Display Module (D1) 040 MODE 1

- Application A Boiler Control 262 & One Stage Setpoint Control 150. Mechanical Remote Display Module (D1) 040 MODE 1 - Application Boiler Control & One Stage Setpoint Control 150 A -1 07/99 echanical Remote Display odule () 040 Outdoor Sensor () 070 150 ODE 1 Class II Transformer 120 V (ac) 24 V (ac) R1 A2 Z1 Z2 Z3 T1

More information

InDEX. A Technical Journal from Caleffi Hydronic Solutions

InDEX. A Technical Journal from Caleffi Hydronic Solutions Caleffi Caleffi North North America, America, Inc. Inc. 9850 3883 South W. Milwaukee 54 th Street Rd Franklin, Milwaukee, WI 53132 Wisconsin 53208 T: 414.421.1000 414.238.2360 F: F: 414.421.2878 414.238.2366

More information

Combined Space and Water Heating: Making it Work

Combined Space and Water Heating: Making it Work Combined Space and Water Heating: Making it Work High Efficiency Heating in a Single Package Ben Schoenbauer, Center for Energy and Environment Jake McAlpine, Sustainable Resource Center February, 26 th,

More information

Lowara ecocirc and ecocirc PREMIUM

Lowara ecocirc and ecocirc PREMIUM Lowara and PREMIUM THE REVOLUTIONARY HIGHLY EFFICIENT CIRCULATORS FOR DOMESTIC HEATING WITH THE SIMPLE AND SHAFTLESS SPHERICAL MOTOR DESIGN AND PATENTED ANTI-BLOCK TECHNOLOGY How can efficiency work The

More information

- Data Brochure Boiler Control 264

- Data Brochure Boiler Control 264 - Data Brochure Boiler Control 264 D 264 11/03 The tekmar Boiler Control 264 can control the supply water temperature from up to 4 on / off stages based on outdoor temperature, control for Domestic Hot

More information

- Data Brochure Mixing Control 361

- Data Brochure Mixing Control 361 TIME PRGM 1 2 AMPM UN OVR S M T W T F S - Data Brochure Mixing Control 361 D 361 05/00 The Mixing Control 361 is designed to control the supply water temperature to a hydronic system in order to provide

More information

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations Series 600 LFI / CFI Series 700 HFS Zone Control Stations Heating and Radiant Floor Zone Control Stations Installation Instructions Thank you for purchasing the finest in heating and radiant floor Control

More information

BHSAPPMAN 08/00 USA. Applications Manual. Ecomatic / Logamatic Controls. Save These Instructions!

BHSAPPMAN 08/00 USA. Applications Manual. Ecomatic / Logamatic Controls. Save These Instructions! BHSAPPMAN 08/00 USA Applications Manual Ecomatic / Logamatic Controls Save These Instructions! TABLE OF CONTENTS 1 2 3 4 5 6 7 8 Introduction 1 Terms 2-4 Description of Wiring Terminals 5-7 Application

More information

Dunkirk H 2 O. Innovative. Efficient. Dependable. Dunkirk.

Dunkirk H 2 O. Innovative. Efficient. Dependable. Dunkirk. Innovative. Efficient. Dependable. Dunkirk. Dunkirk H 2 O - Stainless Steel Single Indirect Water Heaters - Stainless Steel Storage Tanks - Stainless Steel Hydronic Buffer Tanks - Stainless Steel Single

More information

SAMPLE. added benefit of reduced operating costs during low demand periods, such as spring and fall.

SAMPLE. added benefit of reduced operating costs during low demand periods, such as spring and fall. Chapter 4 Variable-speed pumps. A variable-speed pump varies the flow rate by maintaining a constant pressure differential as zone valves open and close. A sensor measures the difference in pressure between

More information

Dunkirk H 2 O. Innovative. Efficient. Dependable. Dunkirk.

Dunkirk H 2 O. Innovative. Efficient. Dependable. Dunkirk. Innovative. Efficient. Dependable. Dunkirk. Dunkirk H 2 O - Stainless Steel Single & Dual Indirect Water Heaters - Storage Tanks - Hydronic Buffer Tanks Introducing the NEW Dunkirk H 2 O Series... A complete

More information

2017 Product Catalog. Commercial Flow Centers Insulated Pumps, & Accessories. Residential Flow Centers. Accessories/Pipe/Fittings

2017 Product Catalog.  Commercial Flow Centers Insulated Pumps, & Accessories. Residential Flow Centers. Accessories/Pipe/Fittings Engineered Solutions Making Geothermal & Hydronics Easier www.geo-flo.com Residential Flow Centers Commercial Flow Centers Insulated Pumps, & Accessories Accessories/Pipe/Fittings Tools/Replacement Pumps

More information

AQ475A Aquatrol Outdoor Temperature Compensator for Boilers

AQ475A Aquatrol Outdoor Temperature Compensator for Boilers A Aquatrol Temperature Compensator for s Features PRODUCT DATA Adjustable settings for boiler maximum temperature, boiler minimum temperature and outdoor low (design) temperature. Selectable Warm Weather

More information

PEERLESS PUREFIRE Installation, Operation, and Maintenance Instructions Supplement - PF-460 NOTICE. Exhaust Vent/Air Intake Size

PEERLESS PUREFIRE Installation, Operation, and Maintenance Instructions Supplement - PF-460 NOTICE. Exhaust Vent/Air Intake Size PEERLESS PUREFIRE Installation, Operation, and Maintenance Instructions Supplement - PF-460 NOTICE These instructions are intended to supplement the Peerless PUREFIRE Installation, Operation, and Maintenance

More information

WIRING GUIDE. Form rev.1. Certified to CSA C22-2 No.24 Conforms to UL Standard 873

WIRING GUIDE. Form rev.1. Certified to CSA C22-2 No.24 Conforms to UL Standard 873 WIRIG GUIDE The ZSR101 is a versatile single relay control with two outputs for operating a 120 VAC with boiler enable, or two 120 VAC devices without boiler enable. Features include rear knock outs for

More information

prestige Control Application Supplement - ACVMax

prestige Control Application Supplement - ACVMax 2015-10 Prestige ACVMax Control Sup 12-14-15_ACVMax_Control 12/15/15 7:36 AM Page 1 prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory

More information

qualified heating installer/service technician

qualified heating installer/service technician Instruction manual This manual must only be used by a qualified heating installer/service technician. Failure to comply could result in severe personal injury, death or substantial property damage. Part

More information

Dual Mixing Application

Dual Mixing Application HBX MIXING APPICATION The CPU-000 configured as a Mixing Control allows for mixing of hitemp boiler (supply) water with lower temp system water, bringing several benefits to a hydronic design and installation.

More information

bout your HOUSE Hydronic Radiant Floor Heating CE 4

bout your HOUSE Hydronic Radiant Floor Heating CE 4 A bout your HOUSE CE 4 Long ago, the Romans used radiant floor heating in their bathhouses. For centuries, the Koreans heated their royal palaces and traditional homes in this manner. Today, radiant heating

More information

prestige Control Application Supplement - TriMax

prestige Control Application Supplement - TriMax prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

Heating Control Danfoss Link & Connect Thermostats

Heating Control Danfoss Link & Connect Thermostats Heating Control Danfoss Link & Connect Thermostats www.heating.danfoss.com Table of Contents 1. Introduction 1.1 Segment... 3 1.2 Danfoss Eco programmable radiator thermostat... 3 1.3 Overview of units

More information

- Data Brochure Boiler Control 264e

- Data Brochure Boiler Control 264e - Data Brochure Boiler Control 264e D 264e 09/09 The kanmor Boiler Control 264e can control the supply water temperature from up to 4 on / off stages based on outdoor temperature, control for Domestic

More information

propanel Series Installation Manual

propanel Series Installation Manual propanel Series Installation Manual propanel Series Installation Manual is published by Uponor Wirsbo 5925 148th Street West Apple Valley, MN 55124 (952) 891-2000 2003 Uponor Wirsbo All rights reserved

More information

Dear Hydronic Professional, Dear Hydronic Professional,

Dear Hydronic Professional, Dear Hydronic Professional, Caleffi Caleffi North North America, America, Inc. Inc. 9850 3883 South W. Milwaukee 54 th Street Rd Franklin, Milwaukee, WI 53132 Wisconsin 53208 T: 414.421.1000 414.238.2360 F: F: 414.421.2878 414.238.2366

More information

WWSD. Power. DHW Demand. Maximum. Supply. Minimum Boiler DHW. Zone 1 / Cooling. Pump / Vlv. System Pump. UnOccupied. of full output NRTL/C LR 58223

WWSD. Power. DHW Demand. Maximum. Supply. Minimum Boiler DHW. Zone 1 / Cooling. Pump / Vlv. System Pump. UnOccupied. of full output NRTL/C LR 58223 Dial the desired duration of the period. Press start button at the time of day you want the UnOcc. period to begin. light turns on. 0 = always = always Pump / Vlv System Pump Zone / Cooling NRTL/C LR 58

More information

The Ultimate in Distribution Efficiency. Air Eliminator Dirt Separator Low Loss Header Hydraulic Separator

The Ultimate in Distribution Efficiency. Air Eliminator Dirt Separator Low Loss Header Hydraulic Separator The Ultimate in Distribution Efficiency Air Eliminator Dirt Separator Low Loss Header Hydraulic Separator Air- and dirt-free system water through a single unit, plus hydraulic separation in a low loss

More information