Installation and Operation Manual

Size: px
Start display at page:

Download "Installation and Operation Manual"

Transcription

1 Page 1 Installation and Operation Manual Microseparator System For ES4 Edgers Distributed Exclusively by: Satisloh North America N 116, W Morse Drive Germantown, WI Tel: (262) Fax: (262) Manufactured for Satisloh by: Bazell Technologies Corporation 5066 Commercial Circle Concord, CA Tel: (925) Fax (925) info@bazell.com Web: Bazell Technologies Corporation is a Satisloh Technology Partner M000021_C September 2013

2 Page 2 TABLE OF CONTENTS TABLE OF CONTENTS... 2 PRODUCT DEFINITION... 4 OPERATOR SAFETY... 4 INSTALLATION LIMITATIONS... 5 SPECIFICATIONS... 5 RECEIVING AND INSPECTION... 5 LIFTING... 5 INSTALLATION ELECTRICAL... 6 INSTALLATION PIPING... 6 INLET... 6 OUTLET... 7 WATER MAKE-UP... 7 AIR SUPPLY CHILLER SUPPLY (TEMPERATURE CONTROL OPTIONAL)... 8 START-UP... 9 FILL TANK... 9 CONTROL PANEL FUNCTIONS... 9 STARTING AND STOPPING... 9 ALARMS LOW LEVEL TANK ALARM HIGH LEVEL TANK ALARM LOW TEMPERATURE ALARM HIGH TEMPERATURE ALARM LOW AIR PRESSURE ALARM NO WORK AUTO FILL MODE LEVEL SWITCH ERROR MOTOR OVERLOAD OVERLOAD EMERGENCY STOP DAILY PRODUCT STARTUP TANK CLEANING CONTROL SUMMARY FUNCTION SETUP CALIBRATION WARNINGS, ALERTS AND FAULTS SCREEN CLEANING SYSTEM DIMENSIONS AND UTILITIES... 17

3 Page 3 DRAWING 6SBTB EDGER SYSTEM PROCESS FLOW DRAWING # 6SBTE DRAWING # 6SBTE SYSTEM PARTS LIST DRAWING # 6SBTE LIMITATIONS OF WARRANTY DOCUMENT REPRESENTATION CONTACTING BAZELL TECHNOLOGIES... 26

4 Page 4 Product Definition The Microseparator Edger water system is designed for the clarification of Water used in the edging of ophthalmic lenses. Design elements: Compact design with low water inlet height left or right side entry Automatic PC/HI chip separation Easy lens/block retrieval through operator door Automatic water makeup Refrigeration coil (chiller, thermocouple, controller, etc. optional) Simple push button control interface Designed for use with secondary filters 100 PSI minimum Operator Safety All personnel responsible for operating the Edger System should be required to read these safety and cleaning procedures prior to operation. Important safety devices are built into each system. Please carefully observe the following safety notices. Always disconnect and lock out the power source before working on or near the Edger System. Motor controls should conform to instructions given in the installation manual provided with the Edger System. Motor controllers must be securely and adequately grounded according to NEC and local codes of the specific area. The Chip Separator must be operated with the cover on. Do not place any appendage in the Chip Separator, to avoid being caught by the pneumatic arm. Practice good housekeeping and maintain a Safety Training and Safety Equipment Operation/Maintenance Program for all employees.

5 Page 5 Installation Limitations Specifications Model Name Polycarbonate Removal Maximum Flow Rate Water Tank Water Pump Cooling Coil Control Panel ES4 Edger System Self-cleaning Chip Separator 76 l/min (20 GPM) 304 SS, capacity 80 L (21 gals) Brinkmann Plastic body Copper Per the drawings attached Note: The Microseparator ES4 Edger System is designed to support the recirculating water requirements of (2) edgers only. Any attempt by the owner to utilize the equipment for other than the intended purpose is at his or her own risk. Receiving and Inspection As soon as possible upon receipt of shipment, machine should be uncrated and packing list checked. Any shortages should be reported to Bazell Technologies Corporation immediately. If damage has occurred during transit, file a claim with the carrier and notify Bazell Technologies of such action. Lifting Lift tank from the bottom only using fork lift. Do not lift or strap to the upper half of machine. Machine is top heavy be sure to stabilize load during transport.

6 Page 6 Installation Electrical Refer to: 6SBTE150 Electrical Prints Before proceeding further with the installation, make sure that electrical power is: Domestic: 208 VAC, 10A, 60 Hz, 3ⱷ International: 400 VDC, 6A, 50 Hz, 3ⱷ Open the control panel: shown with optional international voltage. Visually check for shipping damage Pull test the wiring by gently tugging on all wiring at their connections Installation Piping Inlet Position the system to allow gravity drain from the generator to the Edger System. Maintain full pipe size with minimal bends. Maintain a minimum slope of ¼ per linear foot (2 cm/m) of pipe for good drainage. Do not use flexible hose for drain line. There are two inlets, one on each side of the tank. Water Inlet

7 Page 7 Outlet Water Outlet Connect supply piping to filters/edgers here. The flow monitor is installed to shut down the chip separator while Edgers are off line for an extended period of time. Flow Monitor Water Make-up Connect domestic water supply here. Minimum line pressure is 60psi (2.75 bar). The valve has a 1/2 NPT female thread (or BSPT conversion fitting). Domestic water Turn the system on, energizing the makeup valve. Water make up solenoid will turn off when fluid reaches the correct level.

8 Page 8 Air supply Connect 70 psi clean dry air. Air Chiller Supply (Temperature control optional) Shown with optional temperature control valve. Connect chilled water supply to coil here using hoses provided.

9 Page 9 Start-up Fill Tank Fill the tank with water. Total system volume approximately 80 liters (21 gal). Verify 70psi air to Filter/Regulator. Verify incoming voltage matches voltage rating on panel legend. Verify supply line to filters/edgers are secure. Verify fluid lines to chiller are secure. Turn on main breaker. Control Panel Functions Starting and Stopping Press the START button to place the system into operation. To normally stop the Edger, press the STOP button. Do not use the EMERGENCY STOP button for normal stopping. Starting the system will start the Water Supply Pump, and Chip Separator.

10 Page 10 Alarms When the alarm beacon is blinking, one of the following has occurred: Low Level Tank Alarm Tank level is below minimum height for extended amount of time. Check Water is not held up in the Chip Separator, press Start to initiate water makeup. Verify Water Make up is on and Water Make up Valve is operational. High Level Tank Alarm Tank level is above Maximum Height. Check Chip Separator and Edger Tank Screen for Held up water, clear if required. Lower water level in Tank. Clear High Level Alarm. Press green START button to Start Edger Tank Low Temperature Alarm Indicates Low Water Temperature. Check Chiller supply for correct temperature and flow to Edger, verify Chiller valve is operational. High Temperature Alarm Indicates High Water Temperature. Check Chiller supply for correct temperature and flow to Edger, verify Chiller valve is operational. Low Air Pressure Alarm Check supply of service air to machine. Ensure supply valve is open. Check pressure indication on air regulator. No Work Indicates No Water Flow to process supply; Chip Separator will go to standby mode. Chip Separator will automatically restart once Water Flow is resumed. Auto Fill Mode Start System in Auto mode; Press Green Start button to start Auto Fill Mode. Press Green Start button again to Fill Tank. Level Switch Error Check High and Low level switches are able to move freely in tank unobstructed. Motor Overload Indicates the motor overload relay has tripped. A qualified electrician should investigate. Consult electrical diagram or Bazell Technologies directly for more information.

11 Page 11 Overload Indicates a circuit breaker within the electrical panel has tripped. A qualified electrician should investigate. Consult electrical diagram or Bazell Technologies directly for more information. Emergency Stop Indicates red Emergency Stop button set; Reminds operator to reset button. Pull out Emergency Stop button to reset. Daily Product Startup Check air pressure gauge set to 70 psi Check chip separator bin empty if necessary Turn on Main Breaker and depress START Tank Cleaning Frequency of manual tank cleaning is determined by the volume of production - especially non-chip debris of plastics. Because the edgers use straight water without water additives there is the possibility of fungus or bacteria growing within the system. Any additive used must be compatible with the machine tool.

12 Page 12 Control Summary Function Start Stop Setup Calibration Push green START button. Push red STOP button. Push 1 for 2 seconds with system stopped. Push 2 for 2 seconds with system stopped. Setup Message Action Notes System Setup Password: _ Password 5066 Push " " Temperature Sets Control Temperature of Setpoint Water process (20.0 C) Bandwidth (2.0 C) Temperature Control Warning (5.0 C) Chip Separator (15min) No Flow Debounce (30 sec) Water Make up Duration (10 sec) Tank Auto Fill Duration (15 sec) Enter value, Push " " Push " " again to scroll to next screen Sets Max deviation of Temperature control band Sets Alarm Setpoint to 5.0 C of Setpoint Sets the brush actuator extended and retracted timer Timer for No Flow condition; turns Chip Separator Off. Automatically restarts with Flow to process. Timer for Auto Water Make up; Valve opens for timer value Timer for Auto Water Make up; Valve opens for timer value

13 Page 13 Calibration System Setup Password: _ Minimum 4mA Milliamp (4mA) Minimum Temperature (0.0 C) Maximum 20mA Milliamp (20mA) Maximum Temperature (100.0 C) Password 5066 Enter value, Push " " Push " " Push " " again to scroll to next screen Sets Minimum ma scaling Sets Minimum Temperature Sets Maximum ma scaling Sets Maximum Temperature Warnings, Alerts and Faults Edger Tank Low Level Edger Tank High Level Edger Tank Emergency Stop Edger Tank Air Pressure Low Auto Fill Mode Level Switch Error Electrical Overload No Work Tank water level is below minimum height for extended amount of time. Check Chip Separator or Edger Tank Screen for Held up water, clear if required. Press Start to initiate water makeup. Verify Water Make up is on and Water Make up Valve is operational. Tank water level is above Maximum Height. Check Chip Separator or Edger Tank Screen for Held up water, clear if required. Lower water level in Tank. Clear High Level Alarm. Press green START button to Start Edger Tank Indicates red Emergency Stop button set; Reminds operator to reset button. Pull out Emergency Stop button to reset. Indicates inadequate utility air supply; Protects operating without Chip Separator motive air. Check air pressure at regulator; Gauge on regulator should read 75PSI; Check building air supply valve open. Start System in Auto mode; Press Green Start button to start Auto Fill Mode. Press Green Start button again to Fill Tank. Check High and Low level switches are able to move freely in tank unobstructed. Indicates circuit breaker or motor overload tripped; Protects panel against valve solenoid or motor winding overcurrent condition. Refer to qualified electrical service personal; Disconnect power and inspect electrical panel; repair or replace offending load. Indicates no Water Flow to process supply;

14 Page 14 Low Temperature Alarm High Temperature Alarm Chip Separator will go to standby mode. Chip Separator will automatically restart once Water Flow is resumed. Indicates Low Water Temperature. Check Chiller supply for correct temperature and flow to Edger, verify Chiller valve is operational. Indicates High Water Temperature. Check Chiller supply for correct temperature and flow to Edger, verify Chiller valve is operational.

15 Page 15 Screen Cleaning Tilt screen to remove/replace. Flush screen thoroughly from the back side with water. If necessary brush the fine mesh (top side) of the screen with soft nylon bristle brush. Do not use a wire brush. Press cleaned screen firmly into place.

16 Page 16 Be sure the screen is firmly pressed against bottom stop. Be sure the screen is pressed firmly against the chip separator base.

17 Page 17 System Dimensions and Utilities Drawing 6SBTB001

18 Page 18 EDGER SYSTEM PROCESS FLOW Drawing # 6SBTE200

19 Page 19 Drawing # 6SBTE205

20 Page 20 System Parts List Refer to drawing 6SBTE205 ITEM QTY PART NO. DESCRIPTION MATERIAL/SPEC VDC SOLENOID VALVE SMC 24VDC BAZN110 CONTROL PANEL RELAY LOGIC FILTER/REG/PRESSURE SWITCH SMC AR AIR LIMIT VALVE SMC N-X AIR CYLINDER 50 X CON-6SATE001 POLYJECTOR CABINET 304SS AS2OY2000 FLOAT SWITCH N/O 8 1 P-KTF151/290 PUMP, BRINKMANN 3/4HP 190/380V 9 1 CON-6SBTE057A BRUSH ASSEMBLY INCLUDES 9A,B & C 9A 1 CON-6SBTE057 BRUSH BRACKET 304SS 9B 1 CON-6SATD027 BRUSH NYLON 9C 2 CON-6SATE022 GASKET BUNA AS2OY1200 FLOAT SWITCH N/O 11 4 T-CAST-4W779 CASTERS STEEL VDC SOLENOID, WATER MAKEUP ASCO ½ 24VDC SI5000 FLOW MONITOR IFM 24VDC 1 T-6SBTE030 SCREEN ASSEMBLY 304SS/NYLON MESH 1 T-170M76X76 SCREEN MESH NYLON 175MICRON 1 T-6SATW040 COOLING COIL COPPER ½

21 Page 21 Drawing # 6SBTE150

22 Page 22

23 Page 23

24 Page 24

25 Page 25

26 Page 26 Limitations of Warranty Bazell Technologies Corporation shall not be liable, to any extent whatsoever, for any damages resulting from or arising out of the use or performance of this product and related documentation or the procedures specified in this manual, regardless of foreseeability or the form of action, whether in contract, tort (including negligence), breach of warranty, strict liability or otherwise, and including but not limited to damages resulting from loss of data, loss of anticipated profits, or any special, indirect, incidental or consequential damages. In no even shall Bazell Technologies Corporation liability to the user exceed the amount paid by the user to Bazell Technologies Corporation hereunder. The user assumes full responsibility for the results obtained from the use of this product and related documentation and for application of such results. Document Representation This documentation is provided in good faith but without warranty as to correctness, accuracy, reliability, omissions, or otherwise except as provided in writing by an officer of Bazell Technologies Corporation. Contacting Bazell Technologies Bazell Technologies Corporation 5066 Commercial Circle Concord, CA Tel: (925) Fax: (925) web:

Maintenance Manual. VFT micro Chip Compactor Module. Distributed Exclusively by Satisloh. Manufactured for Satisloh by:

Maintenance Manual. VFT micro Chip Compactor Module. Distributed Exclusively by Satisloh. Manufactured for Satisloh by: Maintenance Manual VFT micro Chip Compactor Module Distributed Exclusively by Satisloh Manufactured for Satisloh by: Bazell Technologies Corporation 5066 Commercial Circle Concord, CA. 94520 Tel: (925)

More information

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL GASGUARD Cl 2 Chlorine Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual 2 Table of Contents GasGuard Cl 2 Operating and Instruction Manual General description. 4 Installation..

More information

Installation and Operations Manual

Installation and Operations Manual Installation and Operations Manual H-IM-LLC February 2018 Part No. 25092501 Replaces H-IM-LLC (01/2014) Lead Lag Control System Table of Contents General Safety Information 2 Inspection 2 Warranty Statement

More information

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL GASGUARD LEL 3 Ammonia Sensor OPERATING & INSTALLATION MANUAL GasGuard LEL 3 Operating and Installation Manual 2 Table of Contents 3GasGuard LEL Operating and Instruction Manual General description. 4

More information

InstructIon Manual KrEs EQuIPMEnt stands

InstructIon Manual KrEs EQuIPMEnt stands Instruction Manual Instruction Manual SELF-CONTAINED AND REMOTE Kairak KRES model refrigerated equipment stand units are available in many lengths from 36 to 120 inches long. These units are available

More information

OPERATION & INSTALLATION MANUAL

OPERATION & INSTALLATION MANUAL OPERATION & INSTALLATION MANUAL Model: SIO 14 & SIO 18 Electric Tankless Hot Water Generators Table of Contents SAFETY INFORMATION... 1 INTRODUCTION... 2 Unit Operation:... 2 Unit Freezing:... 3 Maintenance:...

More information

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL GASGUARD O 2 Oxygen Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6 Operation.. 7 Start-up...

More information

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL GASGUARD NH 3 Ammonia Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual 2 Table of Contents GasGuard NH 3 Operating and Instruction Manual General description. 4 Installation.. 4

More information

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications Instruction Manual Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications Manual PCT-3000 Revision 9/2014 The PCT-3000 series control console incorporates

More information

INSTALLATION, OPERATION AND MAINTENANCE

INSTALLATION, OPERATION AND MAINTENANCE INLINE HEATER INSTALLATION, OPERATION AND MAINTENANCE MODELS: ILS SERIES 1.5kW 120V SINGLE PHASE BEFORE YOU BEGIN CHECK ALL ELECTRICAL CONNECTIONS TO ALL COMPONENTS WITHIN THE HEATER FOR TIGHTNESS. CONNECTIONS

More information

EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST TEL NO: ORDER NO: CONTRACT NO:

EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST TEL NO: ORDER NO: CONTRACT NO: Supersedes: (316) Form QTC4-CL2 (617) MODEL QTC4 EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST CUSTOMER: ADDRESS: PHONE: JOB NAME: LOCATION: CUSTOMER ORDER NO: TEL NO: ORDER NO: CONTRACT NO: CHILLER MODEL

More information

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax SPA BLOWER OWNER'S MANUAL 80015-XXXX, 80016-XXXX, 80017-XXXX, 80018-XXXX, 80019-XXXX, 80020-XXXX fax 888.610.3839 2015 323300-015 6/15 THIS PAGE INTENTIONALLY LEFT BLANK. 2 Operating Instructions and Parts

More information

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents GasGuard NH 3 2% General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6

More information

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual GG-NH3-2% AMMONIA GAS SENSOR Installation and Operation Manual 2 GG-NH3-2% Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N CLIMAGUARD Air-to-Air Outdoor Heat Exchangers TX23, TX33, TX38, TX52 Model INSTRUCTION MANUAL Rev. H 2015 Pentair Equipment Protection P/N 10-1008-221 87976519 TABLE OF CONTENTS RECEIVING THE HEAT EXCHANGER...3

More information

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V. HMT-D30-A HMT-D45E-A HMT-D70E-A Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A Portable Dehumidifier Operating Instructions 3119233 V.141217 General Dehumidifier Information RECOMMENDED HUMIDITY LEVELS

More information

Model 7500EB Portable Eyewash with Heater

Model 7500EB Portable Eyewash with Heater INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 7500EB Portable Eyewash

More information

Isotemp Plus General Purpose Laboratory Freezers

Isotemp Plus General Purpose Laboratory Freezers Isotemp Plus General Purpose Laboratory Freezers Catalog Numbers: 13-986-142/142R 13-986-143/143R 13-986-144/144R 13-986-147/147R 104215 Rev. A Table of Contents Introduction...3 Safety Precautions...3

More information

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual GG-H2S HYDROGEN SULFIDE GAS SENSOR Installation and Operation Manual 2 GG-H2S Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by

More information

MaxLite LED MICRO-T PANEL

MaxLite LED MICRO-T PANEL ` Installation Instructions General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all

More information

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents GasGuard H 2-1% General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6 Operation..

More information

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE. Temperature Control Units Water & Oil 0-00 F Portable Chillers 0 - F Central Chillers Packages & Modules 0 - F Pump Tank Stations Chilled or Tower Water 00-0 gallons Cooling Tower Cells 4-40 tons Filters

More information

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications Instruction Manual Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications Manual PCT30006, Revision 9/20/2016 The PCT30006 control enclosure incorporates

More information

MODEL YVAA EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST CUSTOMER: LOCATION: ADDRESS: CUSTOMER ORDER NO: PHONE: JCI CONTRACT NO: JOB NAME:

MODEL YVAA EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST CUSTOMER: LOCATION: ADDRESS: CUSTOMER ORDER NO: PHONE: JCI CONTRACT NO: JOB NAME: Supersedes: 201.28-CL2 (817) Form 201.28-CL2 (1017) MODEL YVAA EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST CUSTOMER: LOCATION: ADDRESS: PHONE: JOB NAME: CUSTOMER ORDER NO: JCI CONTRACT NO: CHILLER MODEL

More information

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual GG-NO2 NITROGEN DIOXIDE GAS SENSOR Installation and Operation Manual 2 GG-NO2 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by

More information

Technical Data. Installation

Technical Data. Installation Technical Services: Tel: (800) 81-91 / Fax: (800) 791-5500 Model 51 (1) Riser Manifold 1-1/ thru 6 Inch (DN40 thru DN150) For NFPA 1 Sprinkler Systems Customer Service/Sales: Tel: (15) 6-0700 / (800) 5-651

More information

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External

More information

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne.

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne. ELECTRONIC FAUCETS INSTRUCTION MANUAL 100 Haul Road Wayne, NJ 07470 Toll Free: (800) 631-0442 customerservice@krowne.com krowne.com Model 16-196 1 3 2 4 6 5 7 1. 2. 3. 4. 5. 6. 7. Aerator Sensor with Cable

More information

Panel Mounted Heat Exchangers by Dantherm, Inc.

Panel Mounted Heat Exchangers by Dantherm, Inc. Panel Mounted Heat Exchangers by Dantherm, Inc. PRODUCT INFORMATION MANUAL C0028 003 Pinnacle OM Manual Rev AB Page 1 of 14 Dantherm, Inc. 110 Corporate Drive, Suite K Spartanburg, SC 29303 Tel # +1 864

More information

TrueClean Compact CIP

TrueClean Compact CIP TrueClean Compact CIP Installation, Operation, and Maintenance Manual www.trueclean.us TrueClean Compact CIP Table of Contents Safety... 1 Important Safety Information.... 1 Introduction... 2 About This

More information

WIRING MODEL 20 Low Water Cut-Off and Pump Control MAXIMUM PRESSURE: 20 PSI INTERNAL WIRING BLUE WHITE UPPER PROBE (FEED OFF) FEED PROBE (FEED ON) ALL

WIRING MODEL 20 Low Water Cut-Off and Pump Control MAXIMUM PRESSURE: 20 PSI INTERNAL WIRING BLUE WHITE UPPER PROBE (FEED OFF) FEED PROBE (FEED ON) ALL No moving parts to stick, wear or hang-up. 20 Series Pump Control Low Water Cut-Off Combination 120 VAC Operating Voltage Max. Pressure 20 psi LISTED No replacement or rebuilding of floats or mechanical

More information

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2 I&M NUMBER: 316-42-15-1 Page: 1 _ Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to

More information

GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL

GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual Warning Use this product only in the manner described in this manual. If the equipment is used in a

More information

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL Installation and Operation Manual 2 GG-2 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified

More information

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL GASGUARDIAN 2 3 2-Channel Controller OPERATING & INSTALLATION MANUAL GasGuardian 2 3 Operating and Installation Manual Table of Contents General description.... 3 Installation. 3 Locating the GasGuardian-2..

More information

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual GG-NH3 AMMONIA GAS SENSOR Installation and Operation Manual 2 GG-NH3 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

Model 1870F Dehumidifier Installation and Operating Manual

Model 1870F Dehumidifier Installation and Operating Manual Model 1870F Dehumidifier Installation and Operating Manual ON/OFF button used to turn dehumidifier on and off Up/Down buttons used to change humidity setting Dehumidifer Control Outlet MODE button used

More information

GG-R REFRIGERANT SENSOR. Installation and Operation Manual

GG-R REFRIGERANT SENSOR. Installation and Operation Manual GG-R REFRIGERANT SENSOR Installation and Operation Manual 2 GG-R Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

Air Pump Up to 800 gallons

Air Pump Up to 800 gallons Air Pump Up to 800 gallons REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. PACKAGE CONTENTS ITEM #PBPAPK40W Questions, problems, missing parts? Before returning to your retailer, call our customer

More information

Industrial Vacuums, Inc

Industrial Vacuums, Inc Instructions/Spare Parts Manual Nilfisk Model GWD255 Drum Top Vacuum CAUTION: This Nilfisk vacuum cleaner is not to be used in explosion-hazardous areas, as serious injury could result. Under no circumstances

More information

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

MaxLite LED VAPOR TIGHT LINEAR FIXTURES A cost effective LED Vapor Tight Fixture features a full length polycarbonate lens and a one-piece white glass reinforced polyester (GRP) body. Designed to meet or exceed seven to 10 foot-candles at 8

More information

TL-105 COLUMN HEATER

TL-105 COLUMN HEATER TL-105 COLUMN HEATER INSTRUCTION MANUAL Timberline Instruments Inc. 1880 S. Flatiron Ct., Unit I Boulder, Colorado 80301 Ph: (303) 440-8779 Fx: (303) 440-8786 info@timberlineinstruments.com www.timberlineinstruments.com

More information

5) Do not start or stop the unit by inserting or pulling out the power plug.

5) Do not start or stop the unit by inserting or pulling out the power plug. 3058080 V170306 PURCHASE INFORMATION Thank you for choosing a Soleus Air Portable Air Conditioner. This Owner s Manual will provide you with valuable information necessary for the proper care and maintenance

More information

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual MANUAL Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual Model FPT 130 Single Point Freeze Protection Heat Trace Control Table of Contents SCFP-CO-F130 Overview... 3 Installation...

More information

Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions V

Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions V Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions 3119233 V.140529 General Dehumidifier Information RECOMMENDED HUMIDITY LEVELS Spring/Summer:

More information

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control Installation and Operation Manual Temperature and Pressure Monitoring for Heating and Cooling Applications Temperature Monitoring Control VALVE OPEN ALARM System= 128 o F Alarm At= 130 o F RESET /BACK

More information

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA. OWNER S MANUAL Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750 Proudly Made in the USA support@aquacomfort.com 888-475-7443 Manufacturing High Quality, High Efficiency Heat

More information

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A Installation Manual Add-on Controller Installation Kit NPE-180A/210A/240A This device is designed to work with NPE-180A/210A/240A water heaters ONLY. WARNING All Installations should be done only by a

More information

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual GG-VL-R REFRIGERANT VENT LINE SENSOR Installation and Operation Manual 2 GG-VL-R Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified

More information

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A SPECIFICATIONS (Revised 1/12/2006) ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A The system shall operate on the principle of light absorption. It shall consist

More information

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA OWNER S MANUAL Vintage Classic HEAT COOL models Proudly Made in the USA support@aquacomfort.com www.aquacomfort.com/service-and-support 888-475-7443 Manufacturing High Quality, High Efficiency Heat Pump

More information

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

GG-EM ENTRANCE MONITOR. Installation and Operation Manual GG-EM ENTRANCE MONITOR Installation and Operation Manual 2 GG-EM Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

ion Genesis Pump Controller

ion Genesis Pump Controller High Water Alarm Document No.: IONG_OM Page 1 of 7 Table of Contents Safety Precautions.......................... 1 General Overview.......................... 1 Installation.................................2

More information

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual Warning Use this product only in the manner described in this manual. If the equipment is used in a

More information

Control Panel For Water Wash Hoods AM2

Control Panel For Water Wash Hoods AM2 Control Panel For Water Wash Hoods AM2 For further information Call: (919) 554-1025 Or Fax: (919)554-1525 Aqua-Matic 117 Franklin Park Ave. Youngsville, NC 27506 TABLE OF CONTENTS AQUA-MATIC LIMITED WARRANTY

More information

Remote Relay Module (RRM)

Remote Relay Module (RRM) Remote Relay Module (RRM) Instruction Manual WARNING THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR INSTALLING, USING OR SERVICING THIS PRODUCT. Like

More information

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

Model/Sprinkler Identification Number JULY, 2011 WARNINGS Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series EC-11 & EC-14 11.2 and 14.0 K-factor Extended Coverage (Light and Ordinary Hazard) Upright, Pendent, and Recessed Pendent Sprinklers

More information

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit Installation Manual Add-on Controller Installation Kit NPE-180A/240A This device is designed to work with NPE-180A/240A models ONLY. WARNING All Installations should be done only by a qualified expert

More information

M770 ph Controller Owner s Manual

M770 ph Controller Owner s Manual M770 ph Controller Owner s Manual Table of Contents I. Introduction page 2 A. Water Chemistry page 2 B. Safety page 3 C. System Components page 4 D. Specifications page 7 E. Controller Panel Descriptions

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 483502 Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the

More information

Snifter ATEX22 VERSION. User Manual. Distributor

Snifter ATEX22 VERSION. User Manual. Distributor Snifter ATEX22 VERSION User Manual Distributor Version 1.4 09/09/2009 Table of Contents 1. INTRODUCTION... 3 1.1. Safety... 3 1.2. Product overview... 4 1.3. How does it work?... 4 2. INSTALLATION... 5

More information

READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER. Water Tempering Device. Installation, Operation, and Maintenance Manual

READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER. Water Tempering Device. Installation, Operation, and Maintenance Manual READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER Water Tempering Device Installation, Operation, and Maintenance Manual Table of Contents Overview Features Summary...................................... 1

More information

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers. ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page

More information

Corrosion Resistant Fluid and Air Handling Systems.

Corrosion Resistant Fluid and Air Handling Systems. Socket Fusion Hand Tool Operation & Maintenance Manual Corrosion Resistant Fluid and Air Handling Systems. Description The Simtech portable socket fusion machines are available in two size ranges ½ -2

More information

EC3-X33 Stand-alone Superheat Controller Technical Data

EC3-X33 Stand-alone Superheat Controller Technical Data Technical Data EC3-X33 is a stand-alone universal superheat controller for air conditioning, refrigeration and industrial applications such as chillers, industrial process cooling, rooftops, heat pumps,

More information

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual GG-CO-EXP CARBON MONOXIDE SENSOR Installation and Operation Manual 2 GG-CO-EXP Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by

More information

Model 7501/7501T/7501TH/7501T240/7501T240H Portable Eyewash/Portable Eyewash with Heater

Model 7501/7501T/7501TH/7501T240/7501T240H Portable Eyewash/Portable Eyewash with Heater INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS No. 2080045(15) Model 7501/7501T/7501TH/7501T240/7501T240H Portable Eyewash/Portable Eyewash with Heater NOTE TO INSTALLER: Please leave this information

More information

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description. Technical Services: Tel: (00) 31-9312 / Fax: (00) 91-5500 Customer Service/Sales: Tel: (1) 50-5000 / (00) 55-523 Fax: (1) 50-5010 / (00) -1295 Model A Pipe Line Strainer 3,,, & 10 Inch (DN0, DN100,, DN200

More information

Inline Heater for Solvent or Gas. Installation and Operation Manual

Inline Heater for Solvent or Gas. Installation and Operation Manual SH Series Inline Heater for Solvent or Gas Installation and Operation Manual This instruction manual explains the basic operation of the Process Technology inline solvent or gas heater. We recommend reading

More information

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle USE AND CARE GUIDE FOR MODEL MEK1, MEK15 Express Cordless Kettle IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed, including the following: 1. Read

More information

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA OWNER S MANUAL Models: AC110, AC125, AC150 made from 2003 through 2010 Proudly Made in the USA support@aquacomfort.com www.aquacomfort.com/service-and-support/ (888) 475-7443 Manufacturing High Quality,

More information

OPERATING MANUAL/ INSTALLATION

OPERATING MANUAL/ INSTALLATION NHW- 15 HOT WATER MACHINE OPERATING MANUAL/ INSTALLATION 120/240 V 1650/6600 W US 120/240 V 1350/5500 W CAN CONVERTIBLE 2 GA LLON DRIP TRAY INCLUDED ADVANCED TEMPERATURE CONTROL TVT TECHNOLOGY NEWCO ENTEPRISES

More information

AQUA LOGIC S MULTI-TEMP Water-Cooled Marine Duty Series chiller

AQUA LOGIC S MULTI-TEMP Water-Cooled Marine Duty Series chiller AQUA LOGIC S MULTI-TEMP Water-Cooled Marine Duty Series chiller INSTALLATION & OPERATING INSTRUCTIONS Effective 8-19-15 Thank you for purchasing an Aqua logic chiller. It has been designed and built to

More information

Pressurized Filter Up to 1250 gallons

Pressurized Filter Up to 1250 gallons Pressurized Filter Up to 1250 gallons REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. ITEM #FP1250UV Questions, problems, missing parts? Before returning to your retailer, call our customer service

More information

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL DATE OF PURCHASE: MODEL: SERIAL NO.: Record above information from nameplate. Retain this information for future reference.

More information

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL OWNERS MANUAL CARBON MONOXIDE DETECTOR MODELS Panel mount and Remote Detectors (R) (353 and 353R) 353 FAMILY MODEL OWNERS/INSTALLATION MANUAL Page 1 of 22 LOG OF REVISIONS REV NO. PAGE NO. DATE DESCRIPTION

More information

Advantage Series Bathing System Specifications

Advantage Series Bathing System Specifications Advantage Series Bathing System Specifications 6000 Series 6300 Series 450 Main Street, Somerset, WI 54025 Phone: 715.247.5625 Fax: 715.247.3424 http://www.apollobath.com The information in this manual

More information

Model 1850F Dehumidifier Installation and Operating Manual

Model 1850F Dehumidifier Installation and Operating Manual Model 1850F Dehumidifier Installation and Operating Manual ON/OFF button used to turn dehumidifier on and off Up/Down buttons used to change humidity setting Dehumidifer Control Outlet MODE button used

More information

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

More information

PodView Level Indicator LI40 Series Manual

PodView Level Indicator LI40 Series Manual PodView Level Indicator LI40 Series Manual Flowline Inc. 10500 Humbolt Street Los Alamitos, CA 90720 Tel: (562) 598 3015 Fax: (562) 431 8507 www.flowline.com Rev A MN204260 1 of 16 INTRODUCTION / TABLE

More information

Instruction Manual for HX-DX and HX-DXHP Heat Exchangers 3 / 2017

Instruction Manual for HX-DX and HX-DXHP Heat Exchangers 3 / 2017 Instruction Manual for HX-DX and HX-DXHP Heat Exchangers 3 / 2017 Model No. HX-36DX Model No. HX-120DX Check packing slip and product to see if they match. If not, contact Aqua Logic immediately!! Important:

More information

REFRIGERATED CONDIMENT RAIL

REFRIGERATED CONDIMENT RAIL REFRIGERATED CONDIMENT RAIL MODEL RCR-4 Installation and Operation Instructions 2M-Z19984 Rev. - 2/13/15 RCR-4 SAFETY SYMBOL These symbols are intended to alert the user to the presence of important operating

More information

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models ASME CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models RETAIN THIS OPERATING MANUAL WITH BOILER. DO NOT DISCARD READ THIS FIRST: The safeguards and instructions

More information

Model 8780 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Tempering Skid General Area Classification & Class I Division 2. No.

Model 8780 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Tempering Skid General Area Classification & Class I Division 2. No. INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com Website: www.hawsco.com Model 8780 Tempering Skid General

More information

HX-1000 & HX-2000 Recirculating Chiller. NESLAB Manual P/N Rev 03/19/97. Instruction and Site Preparation Manual

HX-1000 & HX-2000 Recirculating Chiller. NESLAB Manual P/N Rev 03/19/97. Instruction and Site Preparation Manual HX-1000 & HX-2000 Recirculating Chiller NESLAB Manual P/N 013582 Rev 03/19/97 Instruction and Site Preparation Manual HX-1000 & HX-2000 Recirculating Chiller Table of Contents Preface Compliance... 2 Unpacking...

More information

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models) Temperature Control Units Water & Oil - 00 F Portable Chillers Air & Water-Cooled 0-70 F Central Chillers Air & Water-Cooled Packages & Modules 0-70 F Pump Tank Stations Chilled or Tower Water 00-00 gallons

More information

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F Temperature Control Units Water & Oil - F Portable Chillers Air & Water-Cooled - 7 F Central Chillers Air & Water-Cooled Packages & Modules - 7 F Pump Tank Stations Chilled or Tower Water - gallons Cooling

More information

EQUIPMENT Operation Manual

EQUIPMENT Operation Manual EQUIPMENT Operation Manual DISPENSE TIME ITEM NO. 1464916 PUR CONTROLLER 30ML SYRINGE AUTO MAN HEATER 2 HEATER 1 PRESSURE REGULATOR Loctite PUR-Controller-30ml Syringe Part Number 1464916 TABLE OF CONTENTS

More information

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL www.polartemp.com TABLE OF CONTENT Disclaimer.......................................... Page 3 Inspection, unpacking and FMU setup.................. Page

More information

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations Series 600 LFI / CFI Series 700 HFS Zone Control Stations Heating and Radiant Floor Zone Control Stations Installation Instructions Thank you for purchasing the finest in heating and radiant floor Control

More information

Heater Installation Kit

Heater Installation Kit Instructions - Parts Heater Installation Kit 30677B Part No. 248428 Includes parts needed to install VISCON HP heater onto cart. Order VISCON HP heater separately. Important Safety Instructions Read all

More information

Ozone-Pro Water Treatment System

Ozone-Pro Water Treatment System Ozone-Pro Water Treatment System The new Ozone Pro Water Treatment System is a computer controlled ozone water sterilization system for recycled irrigation waste water. It was designed specifically for

More information

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Model No.: PS08-01 PS10-01 Ref: KY80 KY100 8,000/10,000/12,000 BTU Portable Air Conditioner Operating Instructions Model No.: PS08-01 PS10-01 Ref: KY80 KY100 Model No.: PS12-03 Ref: KY120 3119233 V160310 Thank you for choosing a Soleus Air Portable

More information

INSTALLATION INSTRUCTIONS GPM SERIES LOOP PUMP MODULES

INSTALLATION INSTRUCTIONS GPM SERIES LOOP PUMP MODULES INSTALLATION INSTRUCTIONS GPM SERIES LOOP PUMP MODULES Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving, ahead just as planned. Manual: 2100-212A Supersedes: 2100-212 File: Tab 8

More information

VADA - Rain2Main Automatic Rainwater Controller

VADA - Rain2Main Automatic Rainwater Controller PRODUCT OVERVIEW / APPLICATION The Vada Rain2Main is designed to select between stored rainwater (when available) and mains supply water, and send this water to your toilet cistern, washing machine, garden

More information

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm Ion Endeavor Controller Digital Level Control with Alternation Page 1 of 8 General Overview The Ion Endeavor is a pump controller that senses a water level of up to 72", has a configurable water level/pump

More information

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd. TQ Series Electronic Control Pump Instruction Manual 50Hz ISO 9001 Certified Walrus Pump Co., Ltd. EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. Address: No. 83-14, Dapiantou, Sanjhih

More information

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description

More information

Precise Temperature Control; Compact Footprint

Precise Temperature Control; Compact Footprint Precise Temperature Control; Compact Footprint The Conair EP1 Series Portable Chillers are designed for 1 to 3 ton applications. Available as air-cooled or water-cooled, with pump sizes from 1/4 to 3 Hp

More information