Modelling of Specific Moisture Extraction Rate and Leakage Ratio in a Condensing Tumble Dryer

Size: px
Start display at page:

Download "Modelling of Specific Moisture Extraction Rate and Leakage Ratio in a Condensing Tumble Dryer"

Transcription

1 Modelling of Specific Moisture Extraction Rate and Leakage Ratio in a Condensing Tumble Dryer Lena Stawreberg, Lars Nilsson To cite tis version: Lena Stawreberg, Lars Nilsson. Modelling of Specific Moisture Extraction Rate and Leakage Ratio in a Condensing Tumble Dryer. Applied Termal Engineering, Elsevier, 2010, 30 (14-15), pp < /j.appltermaleng >. <al > HAL d: al ttps://al.arcives-ouvertes.fr/al Submitted on 16 Jan 2012 HAL is a multi-disciplinary open access arcive for te deposit and dissemination of scientific researc documents, weter tey are publised or not. Te documents may come from teacing and researc institutions in France or abroad, or from public or private researc centers. L arcive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recerce, publiés ou non, émanant des établissements d enseignement et de recerce français ou étrangers, des laboratoires publics ou privés.

2 Accepted Manuscript Title: Modelling of Specific Moisture Extraction Rate and Leakage Ratio in a Condensing Tumble Dryer Autors: Lena Stawreberg, Lars Nilsson P: S (10) DO: /j.appltermaleng Reference: ATE 3123 To appear in: Applied Termal Engineering Received Date: 21 October 2009 Revised Date: 21 April 2010 Accepted Date: 24 May 2010 Please cite tis article as: L. Stawreberg, L. Nilsson. Modelling of Specific Moisture Extraction Rate and Leakage Ratio in a Condensing Tumble Dryer, Applied Termal Engineering (2010), doi: / j.appltermaleng Tis is a PDF file of an unedited manuscript tat as been accepted for publication. As a service to our customers we are providing tis early version of te manuscript. Te manuscript will undergo copyediting, typesetting, and review of te resulting proof before it is publised in its final form. Please note tat during te production process errors may be discovered wic could affect te content, and all legal disclaimers tat apply to te journal pertain.

3 Modelling of Specific Moisture Extraction Rate and Leakage Ratio in a Condensing Tumble Dryer Lena Stawreberg 1*, Lars Nilsson 2 1 Department of Energy, Environmental and Building Tecnology, Karlstad University, SE Karlstad, Sweden, 2 Department of Cemical Engineering, Karlstad University, SE Karlstad, Sweden, *Corresponding autor. Tel: ; fax address: lena.stawreberg@kau.se (L. Stawreberg) ABSTRACT Te use of tumble dryers in ouseolds is becoming more common. Tumble dryers, owever, consume large amounts of electric energy. A statistical model over te tumble dryer is created from a design of experiments. Te model will be used to find te best settings for te power supply to te eater, te internal airflow and te external airflow in order to reac a ig specific moisture extraction rate (SMER) and a low leakage ratio of water vapour. Te aim also involves explaining te trends of te SMER and te leakage ratio based on te pysics of te tumble dryer drying process. A statistically significant model, wic can be used for improving te SMER and leakage ratio, was establised from 19 experiments in a condensing tumble dryer. Te results sow tat a ig power supply to te eater, a ig internal airflow and a low external airflow give te igest SMER values. Tis combination of settings also results in te largest leakage ratio values for te dryer. Leakage is most affected by te external airflow. 1

4 Keywords: design of experiments, energy efficiency 1. ntroduction Tumble dryers are common devices in ordinary ouseolds. Tey offer a fast and convenient way of drying textiles, independent of weater conditions. Teir disadvantage, owever, is teir large consumption of energy, i.e. electricity. Te energy use of one unit is small considering te large number of existing dryers and ow often tey are used, te total energy use is considerable. Since 1990, te clotes drying energy consumption in te OECD countries as risen by 32.7% to 77.1TW in 2000, nternational Energy Agency [1]. t is terefore igly desirable to reduce te energy use of tese products. Tere are mainly two types of dryers available on te market today; te venting tumble dryer and te condensing tumble dryer. Te condensing tumble dryer is becoming more frequently used in ouseolds. Tis type of dryer as te advantage tat all eat supplied to te dryer eventually ends up in te laundry room. Tis is especially beneficial in te Scandinavian climate. Additionally, it does not require ducting to exaust te moist air to te outside making it easy to install. Tere is, owever, a leakage of water vapour from te internal system of te dryer, wic sould be minimised in order to avoid ig umidity in te laundry room. Te tird type of dryer available is equipped wit a eat pump. According to Braun et al. [2] and Bansal et al. [3], te air cycle eat pump dryer was found to be significantly more efficient tan te traditional tumble dryer. Te cost of tis dryer, owever, is considerably iger tan te cost of a traditional tumble dryer. 2

5 A few studies are found in te literature in wic te condensing tumble dryer as been investigated regarding its energy use. According to Bansal et al. [3], te energy efficiency of a condensing tumble dryer is 7% iger tan tat of te venting tumble dryer. Tis was determined from a computer model of te dryer. Conde [4] and Hekmat and Fisk [5], owever, state tat te condensing tumble dryer as an increased energy use compared wit te venting tumble dryer. Conde [4] used a computer model in combination wit experiments, wereas te investigation made by Hekmat and Fisk [5] was based on measurements. Cocran et al. [6] found a significant improvement in te energy efficiency of te condensing tumble dryer by incorporating surface tension elements instead of te traditional air to air eat excanger. According to Liu et al. [7], te optimal performance of a condensing tumble dryer using termoelectric elements instead of te air to air eat excanger strongly depends on te intensities of te drying air temperature, te electric power and te total weigt of te clotes. n order to improve te performance of te condensing tumble dryer, a model of te process can be useful. Teoretical models ave been made by Deans [8], Lambert et al. [9], Yadav and Moon [10], and A Bing and Siming [11] regarding te venting tumble dryer. Due to te recycling of air, a more complex teoretical model is required to describe te drying process of te condensing tumble dryer as compared to te venting tumble dryer. Te components of te condensing tumble dryer are densely placed, wic makes it difficult to perform accurate measurements in te dryer, measurements tat could be used for validating a teoretical model. Tis speaks for te use of a design of experiments, i.e., a metod tat provides a way to create a statistical model of te 3

6 process using a low number of experiments. Te design of experiments as been found to be a useful tool for studying drying processes, and especially for making improvements to existing dryers. Tis metod was used for optimising a combined drying process (infrared and infrared-convective drying) of a porous medium in a study carried out by Dutournie et al. [12]. Tey performed experiments wit four factors and tree responses, and tey cose a full factorial central composite design. Dutournie et al. [12] concluded tat te use of experimental designs could be a powerful metod for obtaining optimal operating conditions for a dryer, especially in combined drying. Te response surface metod as been applied by Teppaya and Prasertsan [13] to optimise te drying of rubber wood, by Madamba and Lopez [14] to optimise te osmotic deydration of mango slices and by Hammami and Rene [15] to determine te freeze-drying process variables for strawberries. Nitz and Taranto [16] investigated te drying of beans in a pulsed bed dryer using an experimental design wose results were used for creating a model of te process. An experimental design was also performed by Lopes da Cuna et al. [17], wo studied te drying of mango powder in a spout fluidised bed dryer. Te aim of tis study is to use a design of experiments in order to create a statistical model over te condensing tumble dryer. Te model will be used to find te best settings for te power supply to te eater, te internal airflow and te external airflow in order to reac a ig specific moisture extraction rate (SMER) and a low leakage ratio. Te aim also involves explaining te trends of te SMER and te leakage ratio based on te pysics of te tumble dryer drying process. 4

7 2. Material Te condensing tumble dryer consists of te main components as sown in Fig. 1, i.e., a rotating drum containing te wet textiles, two fans, a eat excanger and an electric eater. Te drying process in a condensing tumble dryer can be described in terms of tree stages considering te drying air: umidification, deumidification and eating. Humidification of te air takes place inside te drum wen te internal airflow encounters te wet textiles. Te temperature of te air decreases as te umidity of te air increases. Te air is deumidified in te eat excanger wic is cooled wit room air. Te umidity of te air is reduced and te temperature is lowered. Finally, te drying air is eated in te electric eater at constant umidity leading to a reduction in relative umidity. Te drum as an inner diameter of 570 mm and a lengt of 390 mm. Te size of te cross flow plate eat excanger is 230 mm wide, 90 mm ig wit a lengt of 320 mm and consists of 10 orizontal plates. Four different periods are recognised during te drying cycle of a condensing tumble dryer: (1) te eating period, (2) te constant drying rate period, (3) te falling drying rate period, and (4) te cooling period. n te eating period, te wet textiles are eated until an equilibrium temperature is reaced and te constant drying rate period begins. Te drying rate remains constant until te water at te surface of te textiles as evaporated. During te falling drying rate period, wen water is transported from witin te textiles to te surface, te temperature of te drying gas leaving te drum increases. Wen te textiles ave reaced te desired moisture content according to te cosen drying program, te cooling period begins during wic time no power is supplied to 5

8 te eater of te dryer. 3. Metod 3.1. Statistical model for SMER and leakage ratio A design of experiments was used to identify significant factors and to determine ow tey interact. Te power supply to te eater, te internal and te external airflows were studied as factors affecting te performance of te dryer. Te experiments were laid out in a symmetrical fasion around five standard reference experiments. Eac factor was varied between a maximum and minimum value as sown in Table 1. Te software used for te study was MODDE 7.0. Te responses were: (1) te specific moisture extraction rate SMER [g/kj] determined by SMER m m Q Wi Wo =, (1) tot and (2) te leakage of water expressed in percentage of te total evaporated mass of water according to L V = m Wi m Wo m C m Wi m Wo. (2) Te SMER sows te ratio between te amount of evaporated water and te total energy supply. A ig SMER would indicate an efficient drying process wit low 6

9 energy losses. Te leakage of water from te tumble dryer is an important parameter, bot for reducing energy losses from te process and for preventing a umid environment in te laundry room. For tis study, a quadratic regression model was cosen wit a central composite facecentred (CCF) design. Tis is a standard design supporting a quadratic model describing linear relations, quadratic relations and interactions between te factors according to (Eriksson et al. [18]): 2 y = β0 + β1q& + β2v& + β3v& E + β11q& + β22v& + β Q& V& + β Q& V& + β V& V& + ε E 23 E 2 + β V& 2 33 E (3) n tis investigation, 19 test runs were made including five standard reference experiments. All tests were performed wit 4 kg of dry cotton (conditioned in room air at 13 C wit te air relative umidity at 31%) wetted to a moisture content of 60% (db). Te weigt of te drying load was registered before and after eac test run. Te weigt of te condensate was also registered. Temperatures of te air in te internal system were measured every second during te process. Mean values from ten seconds were registered. Temperature sensors wit an accuracy of ± 0.5 C were placed between te eater and te drying drum, T, next to te fan tat transports te internal airflow, T f, and between te eat excanger and te 7

10 eater, T x, see Fig. 1. Te temperatures of te inlet and te outlet external airflow, T HXi and T HXo (also indicated in Fig. 1.), and te temperature of te condensed water leaving te dryer, T C, were measured. Te power supply to te eater and tat to te motor rotating te drum and te fans of te dryer was registered for eac test run. Mean values over ten seconds were measured wit an accuracy of ± 1%. Te power supply to te eater was adjusted by on-off regulation wit a set target value. Te mean value of te measured power supply during eac test was used in te analysis. All power supplied to te eater was assumed to increase te temperature of te internal airstream. Te power supply to te motor rotating bot fans and te drum was 145W. Tree different impellers were used to regulate te internal airflow according to te values in te experimental design set at 88m 3 /, 77m 3 / and 66m 3 /, respectively. Te internal airflow over te electric eater was determined from tests performed wit a dry load according to Q& V& =. (4) ρ c T T ) p ( x Te external airflow was reduced by covering te inlet duct and it was determined from te assumption tat te energy loss from te internal airflow passing troug te eat excanger was transferred completely to te external airflow. As te tests were performed wit a dry load, te external airflow was determined by 8

11 V& ρ ( T f Tx ) V& E =. (5) ρ ( T T ) E HXo HXi Te external airflow in te original dryer was 155 m 3 /. By covering te inlet duct te external airflow was reduced to 113 m 3 / and 72 m 3 / Pysical model for SMER Te following assumptions were made in te pysical model over te drying process in te condensing tumble dryer: relations are determined only for te constant drying rate period; te entalpy of te drying air is constant over te drum, = f ; te relative umidity of te air leaving te drum is 100%; te relative umidity remains at 100% trougout te eat excanger; te internal mass flow of dry air is constant trougout te internal system; and te eat excanger is considered infinitely large. n a condensing tumble dryer all parameters depend on eac oter, wic made it necessary to find a starting point for te calculations. An internal airflow temperature between te eat excanger and te eater, T x, was terefore set to a value representing a test run in te dryer. Tis value for T x was later verified by a calculated value produced from material and energy balances for all components in te system. Te fundamental equations used in te model can be found in Pakowski and Mujumdar [19]. Te umidity of te air between te eat excanger and te eater, Y x, was calculated 9

12 from a correlation for air saturated wit water vapour, and te entalpy, x, was determined by x = c T + Y ( c T ) 0. (6) pa x x pv x + Te mass flow of dry air in te internal system was determined by V& ρ & =, (7) Y +1 m A x were te density of te umid air was determined from tabled values of pressure and temperature at a relative umidity of 100% and te ideal gas relation. Te umidity of te air remains constant over te eater, and te temperature of te air after te eater, T, was determined from T = m& A ( c p Q& + c A p V Y x + T ) x. (8) Te entalpy, = f, was determined from te temperature and te umidity of te air between te eater and te drum similarly to equation (6). Te umidity of te air leaving te drum, Y f, was calculated from a correlation for air saturated wit water vapour. 10

13 Te eat transfer of te eat excanger was determined bot from te internal and te external airflow. Te eat transfer gained by te external airflow over te eat excanger was Q& = V& ρ c T T ). (9) HX E E p ( HXo HXi Te room air temperature was set to 20 C and te eat excanger was assumed to be infinitely large. Tus, te temperatures of te external and te internal airflow leaving te eat excanger ad te same value. Te eat transfer from te internal airflow was Q & = m& [ + ( Y Y ) c T ]}. (10) x { f x f x p x A W Te condensed water leaving te eat excanger was assumed to ave te same temperature as te internal airflow leaving te eat excanger. n te ideal process, te internal and external eat transfer sould be equal as tere would be no eat losses or leakages. However, to be able to relate te results from te model to te investigated tumble dryer, te ratio of te external eat transfer to te internal eat transfer was set to 0.78 in te model due to eat losses and leakages. Tis value was cosen to give te temperatures in te model a value not exceeding C off te measured values of T x. n te ideal drying process te SMER for te constant drying rate period is determined by 11

14 Y Y SMER & A & f x = m. (11) Q 3.3. Leakage ratio Te leakage ratio depends on te umidity of te internal airflow, te pressure difference between te internal system and te surroundings as well as on te size of te cavities. Te area of te cavities will not vary between te different tests implying tat tere sould be a correlation between te umidity, te static pressure and te leakage ratio. By using te measured temperature between te drum and te eat excanger in combination wit te assumption of 100% relative umidity at te drum outlet in te dryer, te umidity of te airflow was determined from a Mollier cart. Te influence of te pressure differences on te leakage was not furter investigated in tis study. As a first approximation, ten, leakage ratio depends on te umidity of te circulating air. 4. Results Te results from te tests performed in te condensing tumble dryer are sown in Table 2. Te mean value of te measured power supply to te eater deviates sligtly from te target values in te experimental design and as terefore been adjusted to te measured value. Te measured values of te leakage ratio deviated from te normal distribution and were terefore logaritmically transformed. A normal distribution of te response is required in te regression analysis. Te statistical model sows good significance. Wen interpreting te results from te model, it is important to point out tat te deviation between te target values of te power supply to te eater and te actual 12

15 measured values will make te model unsymmetrical. Tis can be studied troug te condition number, wic was 3.7 for tis study. For tis type of design, it sould be in te range of 3 8 according to Eriksson et al. [18]. Tis would mean tat te model is acceptable. Anoter important issue is te interval cosen for te experiments, wic is below te settings used for te original dryer. Results from te five standard reference experiments sow a good precision as te mean value of SMER was ± 0.002g/kJ and te leakage ratio was 37 ± 1.3%. nteractions including te external airflow ( V & V& and V & E Q& ) and te quadratic 2 E coefficient of te external airflow ( V & ) were statistically insignificant in te description of SMER. Te correlation between te investigated factors and SMER is terefore, according to equation (3), described by E SMER = Q& V& V& E Q& V& Q& V&. (12) No interactions were significant in te correlation for te leakage ratio and only te quadratic coefficient of te power supply to te eater was significant. Te logaritmically transformed leakage ratio is, according to equation (3), described by L V = 10 exp( Q& V& V& E Q& ). (13) 2 An ANOVA test sows tat te regression models are significant and statistically good for bot SMER and leakage ratio. Bot te goodness of fit (R2) and te goodness of 13

16 prediction (Q2) are ig. For SMER, R2 is and Q2 is For leakage, R2 is and Q2 is A confidence level of 95% was used. Tere was no lack of fit for any of te models. Te model error is in te same range as te pure error and te model sows good fit to te data. n Fig. 2, te SMER of different power supplies and different external and internal airflows is sown in a surface response plot. Low external airflow and ig power supply to te eater gives te igest SMER value. t can also be seen tat an increased internal airflow also increases te SMER, especially at ig power supply to te eater. Low internal airflows in combination wit ig external airflows give te lowest values for te leakage ratio. Te power supply to te eater as a minor effect on te response, as sown in Fig. 3. Te SMER as determined from te pysical model over te tumble dryer is sown in Fig. 4 plotted against te values from te statistical model. Te relation between te pysical model and te statistical model generated from MODDE can be described by SMER Pysical =1.17SMER Statistical (14) wit R 2 =

17 Based on te assumption tat te umidity of te internal airflow will affect te leakage of water from te dryer, te leakage ratio and te umidity of te internal airflow exiting te drum are plotted against te external airflow in Fig. 5. Te leakage ratio presented in te figure is determined from te statistical model, and te umidity is determined from measurements of temperature in te dryer. Te relative umidity of te air exiting te dryer was assumed to be 100%. An increased external airflow leads to a decrease in te umidity of te air and tereby also to a decreased leakage ratio. 5. Discussion Te results from te statistical model sow tat it is not possible to find settings tat simultaneously give a low leakage ratio and a ig value of SMER for te investigated tumble dryer. Bot te external airflow and te power supply to te eater affect te SMER strongly. n Fig. 2 it can also be seen tat tere is a significant interaction between te power supply to te eater and te internal airflow; te iger te power supply, te more a cange in internal airflow affects te SMER. Tis could be explained by te increased temperature in te tumble dryer due to a ig power supply to te eater, wic will lead to increased moisture contents in te internal airflow. An increased internal airflow will terefore be required in order to transport te evaporated moisture from te textiles. According to te results from te statistical model, te leakage ratio as a strong correlation wit te external airflow. A ig external airflow gives a low leakage ratio. n Fig. 3 it can be seen tat bot a low and a ig power supply to te eater give approximately te same leakage. Tis can be a result of te required drying time. A low 15

18 external airflow togeter wit a low power supply to te eater will result in a longer drying time. f te process is long, larger leakages can be found if te umidity of te internal airflow is ig. t can, owever, also be a result of te effectiveness of te eat excanger related to an increased power supply to te eater. f te cooling of te eat excanger becomes too low as te umidity of te internal airflow increases, less water will condense in te eat excanger. Te efficiency of te eat excanger is an important factor, wic as also been pointed out by Cocran et al. [6] and Liu et al. [7]. Canges in te internal airflow will increase or reduce te leakage ratio similarly, independent of external airflow or power supply to te eater. Tis indicates tat canges in te internal airflow will cange te static pressure in te internal system. An increased pressure resulting from a iger airflow will lead to an increased leakage ratio. Pressure differences in te system sould be furter investigated. Te pysical model presented in tis study is a simplified version using ideal assumptions, for te beaviour of te components and is limited to modelling te conditions during te constant drying rate period. According to Fig. 4 it can be determined tat, trougout te study, te values for SMER from te pysical model are iger tan te ones from te statistical model. t seems to be possible to use a simple ideal model in order to see a trend, but not for acieving accurate values. Te pysical model sows ow te umidity, togeter wit te temperature, will affect te SMER, assuming drying takes place in te period of constant drying rate. t can be seen tat tere is a correlation between te two models te iger te temperature and umidity, te iger te SMER. Terefore, it can be concluded tat te constant drying rate period as a large influence on te drying process in te condensing tumble dryer. 16

19 As te pysical model is created from an ideal process, te result from tis study sows tat te performance of te components in te dryer mainly follows te ideal process in te investigated interval. Te pysical model, owever, will not give any information about wic factor is te most important. t sould also be pointed out tat bot te presented models are valid for a specific interval and for a specific tumble dryer. n Fig. 5 it is sown tat an increased external airflow will lead to decreased umidity as well as to a reduced leakage ratio. Tis agrees wit results from bot models: te statistical model sows tat te leakage ratio decreases wit an increasing external airflow, wereas te pysical model sows tat increasing external airflow (better cooling) leads to a decreased umidity of te circulating air. Unfortunately tis poses a problem wen trying to combine a ig SMER and a low leakage. A iger SMER is acieved as te umidity of te circulating airflow is increased. Tis, owever, directly leads to iger leakage, wic is undesirable in te laundry room. Te results from tis study imply tat te use of a statistical model is a good coice wen studying an existing dryer. Te presented model can be used for improving te performance of te tumble dryer by finding profitable settings, but also for improved knowledge about te process. Wen investigating a different type of tumble dryer, a new design of experiments sould be made to detect differences between te dryers regarding sealings, te efficiency of te various components, etc. t is difficult to point out te best settings for te dryer as regards te igest possible SMER and a low leakage ratio, as tey do not correlate. Today, te focus of te 17

20 manufacturers primarily lies on increasing te SMER. t is important to reduce te energy use considering te energy classifications on te market. Tere is still no official classification system regarding leakage, but te figures are neverteless often sown in market tests. Leakage is tus an important parameter to reduce considering te environment in te laundry room. 6. Conclusions A design of experiments performed in MODDE gives a statistically significant model tat can be used as a tool for improving te SMER and reducing te leakage from te condensing tumble dryer. A ig power supply to te eater, a ig internal airflow and a low external airflow give te igest SMER value. Bot power supply to te eater and te external airflow ave a large effect on te SMER according to te model presented by MODDE. A simplified ideal model confirmed tat calculations made over te constant drying rate period are representative for te drying process in identifying trends of ow SMER canges, but tey are not sufficient to provide accurate values. Te leakage ratio is most affected by te external airflow. Tere is a correlation between te moisture content of te air in te internal system and te leakage ratio at different external airflows. A ig moisture content leads to increased leakage. 18

21 Nomenclature c p specific eat capacity [kj/kg C] entalpy [kj/kg] 0 evaporation entalpy, 0 C [kj/kg] L V leakage of water vapour [kg] m mass [kg] m& mass flow [kg/s] Q tot total energy supply [kj] Q & eat transfer [W] SMER specific moisture extraction rate [g/kj] T temperature [ C] V & volume flow [m 3 /s] Y umidity [kg/kg] ρ density [kg/m 3 ] Subscripts A C cover E f x HX i o V W air condensate outer cover of te dryer external between fan and eat excanger (internal system) between eater and drum (internal system) between eat excanger and eater (internal system) eat excanger external airflow (external system) internal inlet outlet vapour water 19

22 References [1] nternationalenergyagency, Cool Appliances - Policy Strategies for Energy Efficient Homes, EA Publications, Paris, [2] J.E. Braun, P.K. Bansal, E.A. Groll, Energy Efficiency Analysis of Air Cycle Heat Pump Dryers, nternational Journal of Refrigeration 25 (7) (2002) [3] P.K. Bansal, J.E. Braun, E.A. Groll, mproving te Energy Efficiency of Conventional Tumbler Clotes Drying Systems, nternational Journal of Energy Researc 25 (15) (2001) [4] M.R. Conde, Energy Conservation wit Tumbler Drying in Laundries, Applied Termal Engineering 17 (12) (1997) [5] D. Hekmat, W.J. Fisk, mproving te Energy Performance of Residential Clotes Dryers, Te 35t Annual nternational Appliance Tecnical Conference, Oio State University, [6] M. Cocran, J. Goodnigt, B. Babin, S. Eckels, Condensing Dryers wit Enanced Deumidification Using Surface Tension Elements, Applied Termal Engineering ) [7] D. Liu, F.-Y. Zao, G.-F. Tang, Modeling and Performance nvestigation of a Closed-Type Termoelectric Clotes Dryer, Drying Tecnology ) [8] J. Deans, Te Modelling of a Domestic Tumbler Dryer, Applied Termal Engineering 21 (9) (2001) [9] A.J.D. Lambert, F.P.M. Spruit, J. Claus, Modelling as a Tool for Evaluating te Effects of Energy-Saving Measures. Case Study. A Tumbler Drier, Applied Energy 38 (1) (1991) [10] V. Yadav, C.G. Moon, Modelling and Experimentation for te Fabric-Drying Process in Domestic Dryers, Applied Energy ) [11] N. A Bing, D. Siming, A New Termination Control Metod for a Clotes Drying Process in a Clotes Dryer, Applied Energy 85 (9) (2008) [12] P. Dutournie, P. Salagnac, P. Glouannec, Optimization of Radiant-Convective Drying of a Porous Medium by Design of Experiment Metodology, Drying Tecnology 24 (8) (2006) [13] T. Teppaya, S. Prasertsan, Optimization of Rubber Wood Drying by Response Surface Metod and Multiple Contour Plots, Drying Tecnology 22 (7) (2004)

23 [14] P.S. Madamba, R.. Lopez, Optimization of te Osmotic Deydration of Mango (Mangifera ndica L.) Slices, Drying Tecnology 20 (6) (2002) [15] C. Hammami, F. Rene, Determination of Freeze-Drying Process Variables for Strawberries, Journal of Food Engineering 32 (2) (1997) [16] M. Nitz, O.P. Taranto, Drying of Beans in a Pulsed Fluid Bed Dryer: Drying Kinetics, Fluid-Dynamic Study and Comparisons wit Conventional Fluidization, Journal of Food Engineering 80 (1) (2007) [17] R. Lopes da Cuna, A.G. de la Cruz, F.C. Menegalli, Effects of Operating Conditions on te Quality of Mango Pulp Dried in a Spout Fluidized Bed, Drying Tecnology 24 (4) (2006) [18] L. Eriksson, E. Joansson, N. Kettane-Wold, C. Wikström, S. Wold, Design of Experiments Principles and Applications, Umetrics AB, Umeå, [19] Z. Pakowski, A.S. Mujumdar, Basic Process Calculations and Simulations in Drying, in: A.S. Mujumdar(ed.) Handbook of ndustrial Drying, Vol. Taylor & Francis Group, Pp

24 Table 1. Experimental design levels of te factors. Factor Low Centre Hig Power supply, Q & 1400 W 1550 W 1700 W nternal airflow, V & 66 m 3 / 77 m 3 / 88 m 3 / External airflow, V & E 72 m 3 / 113 m 3 / 155 m 3 /

25 Table 2. Tests performed in te condensing tumble dryer wit varying values of power supply to te eater, internal airflow and external airflow. Te measured values of SMER and leakage ratio are presented. Experiment Factors Responses number Q & V & V & SMER L E V [W] [m 3 /] [m 3 /] [g /kj] [%]

26 Heater (1.9 kw) T T x Heat excanger Drum T f T HXi nternal airflow (88 m 3 /) T HXo External airflow (155 m 3 /) Fig. 1. Scematic description of a condensing tumble dryer. Temperature sensors are indicated.

27 Fig. 2. Variations of SMER at different external airflows and power supplies to te eater according to te statistical model. Te two surfaces represent two different internal airflows.

28 Fig. 3. Variation of te leakage ratio at different external airflows and power supplies to te eater according to te statistical model. Te two surfaces represent two different internal airflows.

29 SMER -pysical model [g/kj] 0,425 0,415 0,405 0,395 0,385 0,375 0,365 0,355 0,345 0,335 0,325 0,315 0,305 0,295 0,285 0,275 0,265 0,255 0,245 0,235 0,235 0,24 0,245 0,25 0,255 0,26 0,265 0,27 0,275 SMER -statistical model [g/kj] Fig. 4. SMER determined from te pysical model, plotted against SMER determined from te statistical model.

30 60% 0,25 Leakage ratio [%] 50% 40% 30% 20% 10% 0,2 0,15 0,1 0,05 ] Humidity at te drum outlet [kg/kg Humidity at te drum outlet [kg/kg] Leakage ratio Humidity 0% External airflow [m 3 /] Fig. 5. Leakage ratio and umidity of te internal airflow exiting te drum, plotted against te external airflow. Te leakage ratio determined from te statistical model, and te umidity determined from measurements.

The Exploration on the Energy Saving Potential of an Innovative. Dual-temperature Air Conditioner and the Mechanism of the

The Exploration on the Energy Saving Potential of an Innovative. Dual-temperature Air Conditioner and the Mechanism of the Te Exploration on te Energy Saving Potential of an Innovative Dual-temperature Air Conditioner and te Mecanism of te Teoretical Mixed Refrigeration Cycle Zao Lei, Zao Xijin, Hu Andu Professor, graduate

More information

PERFORMANCE IMPROVEMENT POTENTIALS OF LOW GLOBAL WARMING POTENTIAL REFRIGERANTS FOR INTERCITY BUS AIR CONDITIONING SYSTEM

PERFORMANCE IMPROVEMENT POTENTIALS OF LOW GLOBAL WARMING POTENTIAL REFRIGERANTS FOR INTERCITY BUS AIR CONDITIONING SYSTEM THERMAL SCIENCE: Year 0, Vol., No., pp. -4 PERFORMANCE IMPROVEMENT POTENTIALS OF LOW GLOBAL WARMING POTENTIAL REFRIGERANTS FOR INTERCITY BUS AIR CONDITIONING SYSTEM Saban UNAL a, Cagri KUTLU a, and M.

More information

Technical System Catalogue Chillers for IT cooling

Technical System Catalogue Chillers for IT cooling Tecnical System Catalogue Cillers for IT cooling Cillers for IT cooling Te Rittal IT ciller in conjunction wit free cooling supplies exceptionally energy- and cost-efficient IT cooling media. Te system

More information

Improving Single-Sided Room Ventilation by Using a Ceiling Fan

Improving Single-Sided Room Ventilation by Using a Ceiling Fan Improving Single-Sided Room Ventilation by Using a Ceiling Fan Ahmed Rizk, Mustafa Elwan, Ehab Mouris To cite this version: Ahmed Rizk, Mustafa Elwan, Ehab Mouris. Improving Single-Sided Room Ventilation

More information

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant Ravi Verma 1, Sharad Chaudhary 2 1, 2 Department of Mechanical Engineering, IET

More information

FIELD STUDY OF THE ROTARY DESICCANT SYSTEM USING THE CROMER CYCLE BRONISLAVA VELTCHEVA

FIELD STUDY OF THE ROTARY DESICCANT SYSTEM USING THE CROMER CYCLE BRONISLAVA VELTCHEVA FIELD STUDY OF THE ROTARY DESICCANT SYSTEM USING THE CROMER CYCLE By BRONISLAVA VELTCHEVA A THESIS PRESENTED TO THE GRADUATE SCHOOL OF THE UNIVERSITY OF FLORIDA IN PARTIAL FULFILLMENT OF THE REQUIREMENTS

More information

Case Study: Cabinet Cooling Using a Water and Refrigeration System C m C /

Case Study: Cabinet Cooling Using a Water and Refrigeration System C m C / Case Study: Cabinet Cooling Using a Water and Refrigeration System Escalating computing capabilities and srinking cip packages are leading to corresponding increases in server and rack poer densities.

More information

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015) 4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015) Multi-stage Series Heat Pump Drying System with Dehumidification Simulation and Experiment Verification Chao

More information

Analysis of Energy Consumption for Biomass Drying Process

Analysis of Energy Consumption for Biomass Drying Process Environment. Technology. Resources, Rezekne, Latvia Proceedings of the 10 th International Scientific and Practical Conference. Volume II, 317-322 Analysis of Energy Consumption for Biomass Drying Process

More information

Two kinds of gravitational ejector refrigerator stimulation

Two kinds of gravitational ejector refrigerator stimulation Two kinds of gravitational ejector refrigerator stimulation Jacek Kasperski To cite this version: Jacek Kasperski. Two kinds of gravitational ejector refrigerator stimulation. Applied Thermal Engineering,

More information

Numerical Analysis of a Miniature-Scale Refrigeration System (MSRS) for Electronics Cooling

Numerical Analysis of a Miniature-Scale Refrigeration System (MSRS) for Electronics Cooling Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference Scool of Mecanical Engineering 2004 Numerical Analysis of a Miniature-Scale Refrigeration System (MSRS) for Electronics

More information

Influence of temperature and drying air velocity on the kinetics of convective drying in the food industry

Influence of temperature and drying air velocity on the kinetics of convective drying in the food industry Influence of temperature and drying air velocity on the kinetics of convective drying in the food industry Ing. Michal Pěnička Project leader: Doc. Pavel Hoffman CSc. Abstract The aim of this study was

More information

Theoretical and Experimental Analysis of Desiccant Wheel Performance for Low Humidity Drying System

Theoretical and Experimental Analysis of Desiccant Wheel Performance for Low Humidity Drying System Recent Researces Power Systems and Systems Science eoretical and Analysis of Desiccant Weel Performance for Low Humidity Dryg System RI SUYONO, SOHIF MA, MUHAMMAD YAHYA, MUHD. HAFIZ RUSLAN, AZAMI ZAHARIM

More information

Opteon XP10. Opteon XP10 Retrofit Guidelines to Replace R-134a. Refrigerant. Introduction. Important Safety Information

Opteon XP10. Opteon XP10 Retrofit Guidelines to Replace R-134a. Refrigerant. Introduction. Important Safety Information Opteon XP10 Opteon XP10 Retrofit Guidelines to Replace R-134a Introduction Opteon XP10 is a low global warming potential (GWP) ydrofluoro-olefin (HFO)-based refrigerant developed to replace R-134a in medium-temperature

More information

Opteon XP40. Opteon XP40 Retrofit Guidelines to Replace R-404A/R-507. Refrigerant. Introduction. Important Safety Information

Opteon XP40. Opteon XP40 Retrofit Guidelines to Replace R-404A/R-507. Refrigerant. Introduction. Important Safety Information Opteon XP40 Opteon XP40 Retrofit Guidelines to Replace R-404A/R-507 Introduction Opteon XP40 is a low global warming potential (GWP) ydrofluoro-olefin (HFO)-based refrigerant developed as a direct replacement

More information

Opteon XP40. Opteon XP40 Retrofit Guidelines to Replace R-402A (HP80) and R-408A. Refrigerant (R-449A) Introduction. Important Safety Information

Opteon XP40. Opteon XP40 Retrofit Guidelines to Replace R-402A (HP80) and R-408A. Refrigerant (R-449A) Introduction. Important Safety Information Opteon XP40 (R-449A) Opteon XP40 Retrofit Guidelines to Replace R-402A (HP80) and R-408A Introduction Opteon XP40 (R-449A) is a low global warming potential (GWP) ydrofluoro-olefin (HFO)-based refrigerant

More information

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING V. Vakiloroaya*, J.G. Zhu, and Q.P. Ha School of Electrical, Mechanical and Mechatronic Systems,

More information

Shortcut Model for Predicting Refrigeration Cycle Performance

Shortcut Model for Predicting Refrigeration Cycle Performance 17 A publication of CHEMICAL ENGINEERING TRANSACTIONS VOL. 5, 15 Guest Editors: Petar Sabev Varbanov, Jiří Jaromír Klemeš, Sharifah Rafidah Wan Alwi, Jun Yow Yong, Xia Liu Copyright 15, AIDIC Servizi S.r.l.,

More information

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning Available online at www.sciencedirect.com Systems Engineering Procedia () 6 International Conference on Risk and Engineering Management (REM) Thermodynamic analysis of air cycle refrigeration system for

More information

Technical data Chimney fans, controllers & accessories

Technical data Chimney fans, controllers & accessories Tecnical data Cimney fans, controllers & accessories y Solid fuel and wood-burning stoves and fireplaces y Biofuel boilers y Decentralised multiple eating appliances connected to same cimney 1 a D W a

More information

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling Aleksandra Cichoń,*, Anna Pacak, Demis Pandelidis, and Sergey Anisimov Department of

More information

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler International Journal of Thermal Technologies E-ISSN 2277 4114 2015 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijtt/ Research Article Effect of Operating Parameters on the

More information

DETERMINATION OF THE EFFECTIVE MOISTURE DIFFUSIVITY OF RED PEPPER IN A MICROWAVE CONVEYOR DRYER

DETERMINATION OF THE EFFECTIVE MOISTURE DIFFUSIVITY OF RED PEPPER IN A MICROWAVE CONVEYOR DRYER DETERMINATION OF THE EFFECTIVE MOISTURE DIFFUSIVITY OF RED PEPPER IN A MICROWAVE CONVEYOR DRYER Soner ÇELEN +, Ugur AKYOL +, Aytaç MORALAR + + NAMIK KEMAL UNIVERSITY, Çorlu, Tekirda, Turkey. Abstract.

More information

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant International Journal of Scientific and Research Publications, Volume 4, Issue 7, July 2014 1 Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170

More information

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator 18 R. Saidur et al./journal of Energy & Environment, Vol. 6, May 2007 Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator R. Saidur, M. A. Sattar, M.

More information

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid Simulation Analysis of Compression Refrigeration Cycle with Different Refrigerants P.Thangavel, Dr.P.Somasundaram, T.Sivakumar, C.Selva Kumar, G.Vetriselvan Abstract --- In this analysis, the performance

More information

Supporting acoustic environment design in spatial planning of urban areas

Supporting acoustic environment design in spatial planning of urban areas Supporting acoustic environment design in spatial planning of urban areas Waldemar Paszkowski To cite this version: Waldemar Paszkowski. Supporting acoustic environment design in spatial planning of urban

More information

Cassava Chip Drying by Using a Small-Scale Hot-Air Microwave Oven

Cassava Chip Drying by Using a Small-Scale Hot-Air Microwave Oven American Journal of Engineering and Applied Sciences 6 (2): 211-215, 2013 ISSN: 1941-7020 2014 P. Wilaipon, This open access article is distributed under a Creative Commons Attribution (CC-BY) 3.0 license

More information

Design and Development of Water Cooled Condenser for Domestic Refrigerator

Design and Development of Water Cooled Condenser for Domestic Refrigerator Design and Development of Water Cooled Condenser for Domestic Refrigerator Anil S. Patil Research PG Student, GF s Godavari College of Engineering, Jalgaon Dr. Atul A Patil Assot. Prof. GF s Godavari College

More information

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING M. POIRIER, D. GIGUÈRE, Z. AIDOUN, M. OUZZANE Natural Resources Canada, CANMET Energy Technology Centre-Varennes 1615, Lionel

More information

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this lecture are to: 1. Importance of complete vapour compression refrigeration

More information

Evaluation of a dynamic model for a cold climate counter flow air to air heat exchanger

Evaluation of a dynamic model for a cold climate counter flow air to air heat exchanger Evaluation of a dynamic model for a cold climate counter flow air to air heat exchanger Toke Rammer Nielsen, Associate Professor, Department of Civil Engineering, Technical University of Denmark; trn@byg.dtu.dk

More information

New GuideLed safety luminaires

New GuideLed safety luminaires CEAG GuideLed safety luminaires New GuideLed safety luminaires Linear design combined wit ig economy GuideLed SL 111.1, 121.1 CG-S Recessed mounting EN 1838 LED * GuideLed SL 111.1 CG-S IP1 GuideLed SL

More information

Note: Principal version Correction Modification Consolidated version from October Bachelor s Programme in Architecture

Note: Principal version Correction Modification Consolidated version from October Bachelor s Programme in Architecture Note: Te following curriculum is a consolidated version. It is legally non-binding and for informational purposes only. Te legally binding versions are found in te respective issues of te University of

More information

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump IOP Conference Series: Earth and Environmental Science PAPER OPEN ACCESS Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump To cite this article: Yefeng Liu et al 2018 IOP

More information

INDOOR HUMAN THERMAL COMFORT OPTIMAL CONTROL WITH DESICCANT WHEEL COOLING SYSTEM

INDOOR HUMAN THERMAL COMFORT OPTIMAL CONTROL WITH DESICCANT WHEEL COOLING SYSTEM Available online at www.sciencedirect.com ScienceDirect Energy Procedia 61 (2014 ) 882 886 The 6 th International Conference on Applied Energy ICAE2014 INDOOR HUMAN THERMAL COMFORT OPTIMAL CONTROL WITH

More information

Evaluation of fixed point H2S gas detectors intended for use in industrial safety applications

Evaluation of fixed point H2S gas detectors intended for use in industrial safety applications Evaluation of fixed point H2S gas detectors intended for use in industrial safety applications Sébastien Bouchet, Sabine Kasprzycki, Nicolas Lepine, Jean-Charles Morin To cite this version: Sébastien Bouchet,

More information

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY Xiaoyun Xie, Yidan Tang, Xiaoqin Yi, Shuanqiang Liu,Yi Jiang Department of Building Science and Technology,

More information

Hot Air-Microwave Combined Drying Characteristics of Gypsum Board. Won-Pyo Chun, Sung-Il Kim, and Ki-Woo Lee 1

Hot Air-Microwave Combined Drying Characteristics of Gypsum Board. Won-Pyo Chun, Sung-Il Kim, and Ki-Woo Lee 1 European Drying Conference - EuroDrying'11 Palma. Balearic Island, Spain, 26-28 October 11 Hot Air-Microwave Combined Drying Characteristics of Gypsum Board Won-Pyo Chun, Sung-Il Kim, and Ki-Woo Lee 1

More information

Experimental Investigation of a Heat Pump Assisted Fluidized Bed Dryer

Experimental Investigation of a Heat Pump Assisted Fluidized Bed Dryer GRD Journals- Global Research and Development Journal for Engineering Volume 2 Issue 6 May 2017 ISSN: 2455-5703 Experimental Investigation of a Heat Pump Assisted Fluidized Bed Dryer Gokul G Nair Dr. Jeoju

More information

NEW CD WARP CONTROL SYSTEM FOR THE CORRUGATING INDUSTRY

NEW CD WARP CONTROL SYSTEM FOR THE CORRUGATING INDUSTRY NEW CD WARP CONTROL SYSTEM FOR THE CORRUGATING INDUSTRY USING A NEW CONCEPT IN MOISTURE SENSING AND CONTROL BY DRYING TECHNOLOGY, INC A New CD Warp Control System For the Corrugating Industry Introduction:

More information

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION Eighth International IBPSA Conference Eindhoven, Netherlands August 11-14, 2003 EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION Liu Jing 1, Yoshihiro Aizawa 2, Hiroshi Yoshino 3 1 School of Municipal

More information

Mathematical Simulation of Longan Fruit Drying

Mathematical Simulation of Longan Fruit Drying Mathematical Simulation of Longan Fruit Drying Aree Achariyaviriya, Somchart Soponronnarit and Jirawan Tiansuwan ABSTRACT The objectives of this study were to develop a mathematical model and to simulate

More information

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING H. Kotani, R. Satoh, T. Yamanaka Dept. of Architectural Engineering, School of Engineering, Osaka University, Osaka, Japan ABSTRACT The purpose

More information

A New Approach for Modeling of Hot Air-microwave Thin Layer Drying of Soybean

A New Approach for Modeling of Hot Air-microwave Thin Layer Drying of Soybean A New Approach for Modeling of Hot Air-microwave Thin Layer Drying of Soybean Dariush Zare, Assistant Professor, Agricultural Engineering Dept., Shiraz University, Shiraz, Iran. M. Ranjbaran, M. Javidi,

More information

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2006 Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps

More information

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2008 Performance Evaluation and Design Optimization of Refrigerated Display

More information

EEN-E Measurement and Control of Energy Systems DRYING OF BIOMASS IN A FIXED BED DRYER LABORATORY EXERCISE INSTRUCTIONS

EEN-E Measurement and Control of Energy Systems DRYING OF BIOMASS IN A FIXED BED DRYER LABORATORY EXERCISE INSTRUCTIONS EEN-E1040 - Measurement and Control of Energy Systems DRYING OF BIOMASS IN A FIXED BED DRYER LABORATORY EXERCISE INSTRUCTIONS Aalto University Laboratory of Energy Efficiency and Systems 2016 Table of

More information

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM Sachin Kumar 1, Vicky Ranga 2 1Assistant Professor, Department of Mechanical Engineering, Jagan Nath University Jhajjar, Haryana, India. 2Scholar.

More information

Specific Energy Consumption comparative study of Hot Air dryer and Heat Pump dryer for highland drying process Sayompon Srina

Specific Energy Consumption comparative study of Hot Air dryer and Heat Pump dryer for highland drying process Sayompon Srina Specific Energy Consumption comparative study of Hot Air dryer and Heat Pump dryer for highland drying process Sayompon Srina Department of Mechanical Engineering, Faculty of Engineering, King Mongkut

More information

PART I - MODELING DRYING OF THREE-DIMENSIONAL PULP MOLDED STRUCTURES - EXPERIMENTAL PROGRAM

PART I - MODELING DRYING OF THREE-DIMENSIONAL PULP MOLDED STRUCTURES - EXPERIMENTAL PROGRAM Drying '98 - Proceedings of the 11 th International Drying Symposium (IDS '98) Halkidiki, Greece, August 19-22, 1998, vol. A, pp. 349-356 PART I - MODELING DRYING OF THREE-DIMENSIONAL PULP MOLDED STRUCTURES

More information

THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE

THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE Pushpendra Singh 1, Vipin Shrivastava 2 1,2 Mechanical Engineering Department, Lakshmi Narain College of Technology (India) ABSTRACT

More information

Operations & Maintenance Plan for Mold and Moisture Control in Apartment Properties

Operations & Maintenance Plan for Mold and Moisture Control in Apartment Properties Operations & Maintenance Plan for Mold and Moisture Control in Apartment Properties 2002 National Multi Housing Council, Inc. All rigts reserved. Tis O&M Plan is intended for informational purposes and

More information

Falling Film Heat Exchangers for Solar Water Heaters

Falling Film Heat Exchangers for Solar Water Heaters Y.C., G.L. Morrison and M. Behnia School of Mechanical and Manufacturing Engineering University of New South Wales Sydney 2052 AUSTRALIA E-mail: yens@student.unsw.edu.au Abstract The characteristics of

More information

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A ISSN: 2250-0138 (Online) NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A RANENDRA ROY a1, MADHU SRUTHI EMANI b AND BIJAN KUMAR MANDAL c abc Department

More information

solution, due to the partial vapor pressure difference between the air and the desiccant solution. Then, the moisture from the diluted solution is rem

solution, due to the partial vapor pressure difference between the air and the desiccant solution. Then, the moisture from the diluted solution is rem A Simplified model for estimating the regeneration effectiveness of a counter flow regenerator for a liquid desiccant system M.H. Kim 1, H.J. Cho 1, and J.W. Jeong 1* 1 Division of Architectural Engineering,

More information

Room Acoustic Design in Open-Plan Offices

Room Acoustic Design in Open-Plan Offices Room Acoustic Design in Open-Plan Offices Erling Nilsson, Björn Hellström To cite this version: Erling Nilsson, Björn Hellström. Room Acoustic Design in Open-Plan Offices. Société Française d Acoustique

More information

INFLUENCE OF DRYING CONDITIONS ON THE MOISTURE DIFFUSION DURING SINGLE STAGE AND TWO STAGE FLUIDIZED BED DRYING OF BOVINE INTESTINE FOR PET FOOD

INFLUENCE OF DRYING CONDITIONS ON THE MOISTURE DIFFUSION DURING SINGLE STAGE AND TWO STAGE FLUIDIZED BED DRYING OF BOVINE INTESTINE FOR PET FOOD INFLUENCE OF DRYING CONDITIONS ON THE MOISTURE DIFFUSION DURING SINGLE STAGE AND TWO STAGE FLUIDIZED BED DRYING OF BOVINE INTESTINE FOR PET FOOD O. Alves-Filho 1, W. Senadeera, T. Eikevik 1 1 Norwegian

More information

Emergency Lighting Design Guide

Emergency Lighting Design Guide Emergency Ligting Design Guide Step 1 Identify mandatory Points of Empasis for te positioning of luminaires, eamples as follows: FINAL EXIT EXIT SIGNS DIRECTION CHANGE INTERSECTIONS At eac eit door At

More information

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23 Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23 A. D. Parekh, P. R. Tailor Abstract The Montreal protocol and Kyoto protocol underlined the need of substitution

More information

MF-RHT Series - High Temperature PTC Resettable Fuses

MF-RHT Series - High Temperature PTC Resettable Fuses *RoHS COMPLINT, **HLOGEN FREE & EC COMPLINT RH750 7180S Features n Compliant wit EC-Q200 Rev-C- Stress Test Qualification for Passive Components in utomotive pplications n Operating temperature range up

More information

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts International Journal of Current Engineering and Technology E-ISSN 2277 416, P-ISSN 2347 5161 216 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Experimental

More information

A Statistical Analysis of a Liquid Desiccant Dehumidifier/Regenerator in an Air Conditioning System

A Statistical Analysis of a Liquid Desiccant Dehumidifier/Regenerator in an Air Conditioning System Int. J. of Thermal & Environmental Engineering Volume 5, No. 1 (013) 41-50 A Statistical Analysis of a Liquid Desiccant Dehumidifier/Regenerator in an Air Conditioning System Abdulrahman T. Mohammad *,

More information

Specific Energy Consumption of Heat Pump Drying System

Specific Energy Consumption of Heat Pump Drying System Mindanao Journal of Science and Technology Vol.14 (2016) 131-145 Specific Energy Consumption of Heat Pump Drying System Adonis A. Closas 1* and Eliseo P. Villanueva 2 1 College of Engineering and Architecture

More information

Numerical study of heat pipe application in heat recovery systems

Numerical study of heat pipe application in heat recovery systems Numerical study of heat pipe application in heat recovery systems *Song Lin, John Broadbent, Ryan McGlen Thermacore Europe, 12 Wansbeck Business Park Ashington, Northumberland NE3 QW, UK E-mail: song.lin@thermacore.com

More information

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C drop analysis of evaporator using refrigerants R-22, R-404A and R-407C #1 Pallavi Sawkar, #2 Dr. Pradeep Patil #12 Department of Mechanical Engineering, JSPM s JSCOE, Savitribai Phule Pune University,

More information

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential

More information

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air Anna Pacak 1,*, Andrzej Jedlikowski 1, Demis Pandelidis 1, and Sergey Anisimov 1 1 Wrocław University of

More information

Development of a hybrid refrigerator combining thermoelectric and vapor compression technologies

Development of a hybrid refrigerator combining thermoelectric and vapor compression technologies Development of a hybrid refrigerator combining thermoelectric and vapor compression technologies J.G. Vián, D. Astrain To cite this version: J.G. Vián, D. Astrain. Development of a hybrid refrigerator

More information

POTENTIAL OF NON - AZEOTROPIC REFRIGERANT MIXTURE AS WORKING REFRIGERANT IN HOT WATER HEAT PUMPS. FJ Smit and JP Meyer

POTENTIAL OF NON - AZEOTROPIC REFRIGERANT MIXTURE AS WORKING REFRIGERANT IN HOT WATER HEAT PUMPS. FJ Smit and JP Meyer POTENTIAL OF NON - AZEOTROPIC REFRIGERANT MIXTURE AS WORKING REFRIGERANT IN HOT WATER HEAT PUMPS FJ Smit and JP Meyer Research Group for Heating and Cooling Technology, Laboratory for Energy, PO Box 524,

More information

PERFORMANCE ANALYSIS OF A RE-CIRCULATING HEAT PUMP DRYER

PERFORMANCE ANALYSIS OF A RE-CIRCULATING HEAT PUMP DRYER THERMAL SCIENCE: Year 2016, Vol. 20, No. 1, pp. 267-277 267 PERFORMANCE ANALYSIS OF A RE-CIRCULATING HEAT PUMP DRYER by Nurettin YAMANKARADENIZ a, K. Furkan SOKMEN d, Salih COSKUN a*, Omer KAYNAKLI b,

More information

Compression of Fins pipe and simple Heat pipe Using CFD

Compression of Fins pipe and simple Heat pipe Using CFD Compression of Fins pipe and simple Heat pipe Using CFD 1. Prof.Bhoodev Mudgal 2. Prof. Gaurav Bhadoriya (e-mail-devmudgal.mudgal@gmail.com) ABSTRACT The aim of this paper is to identify the advantages

More information

Performance Study of Triple Concentric Pipe Heat Exchanger

Performance Study of Triple Concentric Pipe Heat Exchanger Performance Study of Triple Concentric Pipe Heat Exchanger #1 Pravin M. Linge, #2 A. B. Korane, #3 V. N. Kapatkar #123 Mechanical Engineering Department, Sinhgad College of Engineering, SPPU, Pune, India

More information

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a International Journal of Research in Engineering and Science (IJRES) ISSN (Online): 2320-9364, ISSN (Print): 2320-9356 Volume 4 Issue 6 ǁ June. 2016 ǁ PP. 52-57 Performance analysis of a vapour compression

More information

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A [1] Ranendra Roy, [2] Madhu Sruthi Emani, [3] Bijan Kumar Mandal [1], [2],[3] Department of Mechanical

More information

Concept study of a new method for drying dishware in a heat pump dishwasher

Concept study of a new method for drying dishware in a heat pump dishwasher Energy Efficiency (2017) 10:1529 1538 DOI 10.1007/s12053-017-9541-4 ORIGINAL ARTICLE Concept study of a new method for drying dishware in a heat pump dishwasher Peder Bengtsson & Jonas Berghel Received:

More information

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System M.H.Kim 1, J.Y.Park 1, E.J.Lee 2, and J.W.Jeong 1* 1 Department of Architectural Engineering, Hanyang University,

More information

VENTILATION SYSTEM WITH GROUND HEAT EXCHANGER

VENTILATION SYSTEM WITH GROUND HEAT EXCHANGER Journal of Ecological Engineering Volume 17, Issue 5, Nov. 2016, pages 163 172 DOI: 10.12911/22998993/65466 Research Article VENTILATION SYSTEM WITH GROUND HEAT EXCHANGER Vyacheslav Pisarev 1, Sławomir

More information

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor Mingyue Huang a, Xiangfei Liang a,b *, Rong Zhuang a a Gree Electric Appliances, Inc.of Zhuhai,Zhuhai 519070,China

More information

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature International Journal Of Computational Engineering Research (ijceronlinecom) Vol 3 Issue 3 Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

More information

Experimental study of an energy efficient hybrid system for surface drying

Experimental study of an energy efficient hybrid system for surface drying Experimental study of an energy efficient hybrid system for surface drying W.C Wang, R.K Calay, Y.K Chen To cite this version: W.C Wang, R.K Calay, Y.K Chen. Experimental study of an energy efficient hybrid

More information

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump Available online at www.sciencedirect.com Procedia Engineering 8 (2011) 165 170 2 nd International Science, Social-Science, Engineering and Energy Conference 2010: Engineering Science and Management Hot

More information

Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink

Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink 1 Asoka R.G, 2 Aishwarya N, 3 Rajasekar S and 4 Meyyappan N 1234 Department of Chemical Engineering Sri Venkateswara College of Engineering,

More information

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS Staņislavs GENDELIS, Andris JAKOVIČS Laboratory for mathematical modelling of environmental

More information

An Experimental Study on Drying of Pistacia Terebinthus in a Fixed Bed Dryer

An Experimental Study on Drying of Pistacia Terebinthus in a Fixed Bed Dryer Copyright 2013 Tech Science Press FDMP, vol.9, no.1, pp.1-10, 2013 An Experimental Study on Drying of Pistacia Terebinthus in a Fixed Bed Dryer A. Balbay 1, H. Ülker 2 and Ö. Şahin 3 Abstract: In this

More information

All rights reserved, Armando B. Corripio, PhD, PE, Solid Dryer Design Introduction Continuous Dryer Design...

All rights reserved, Armando B. Corripio, PhD, PE, Solid Dryer Design Introduction Continuous Dryer Design... Solid Dryer Design All rights reserved, Armando B. Corripio, PhD, PE, 2014 Contents Solid Dryer Design... 1 Introduction... 2 1. Continuous Dryer Design... 3 1.1 Mass Balances... 4 1.2 Temperature Profiles...

More information

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger International Journal of ChemTech Research CODEN( USA) IJCRGG ISSN 0974-4290 Vol.5, No.2, pp 925-934, April-June 2013 ICGSEE-2013[14th 16th March 2013] International Conference on Global Scenario in Environment

More information

Incorporating Aluminum Honeycomb to Increase Efficiency of U-tube Removable Heat Exchanger

Incorporating Aluminum Honeycomb to Increase Efficiency of U-tube Removable Heat Exchanger Incorporating Aluminum Honeycomb to Increase Efficiency of U-tube Removable Heat Exchanger Daniel Soto 1 and Daniel Corona 2 California Polytechnic State University, San Luis Obispo, San Luis Obispo, California,

More information

Variable far infrared radiation (VFIR) technique for cubic carrot drying

Variable far infrared radiation (VFIR) technique for cubic carrot drying International Journal of Renewable Energy, Vol. 7, No. 2, July - December 2012 Variable far infrared radiation (VFIR) technique for cubic carrot drying Sirinuch Chindaruksa a *, Pisit Maneechot b, Seishu

More information

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System A D Parekh, and P R Tailor Abstract Because of damaging effect of CFC refrigerants on stratospheric

More information

Cooling the Data Center

Cooling the Data Center Article development led by queue.acm.org doi:10.1145/1721654.1721671 What can be done to make cooling systems in data centers more energy efficient? by Andy Woods Cooling the Data Center Power generation

More information

Control Method Of Circulating Refrigerant Amount For Heat Pump System

Control Method Of Circulating Refrigerant Amount For Heat Pump System Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Control Method Of Circulating Refrigerant Amount For Heat Pump System Jin

More information

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation Marco Alexandre Onofre Dias This paper presents a model that was implemented

More information

Simulation Of Pneumatic Drying: Influence Of Particle Diameter And Solid Loading Ratio

Simulation Of Pneumatic Drying: Influence Of Particle Diameter And Solid Loading Ratio International Journal of ChemTech Research CODEN( USA): IJCRGG ISSN : 0974-4290 Vol.4, No.4, pp 1633-1641, Oct-Dec 2012 Simulation Of Pneumatic Drying: Influence Of Particle Diameter And Solid Loading

More information

EXPERIMENTAL PERFORMANCE ANALYSIS OF AN AMMONIA-WATER DIFFUSION ABSORPTION REFRIGERATION CYCLE

EXPERIMENTAL PERFORMANCE ANALYSIS OF AN AMMONIA-WATER DIFFUSION ABSORPTION REFRIGERATION CYCLE EXPERIMENTAL PERFORMANCE ANALYSIS OF AN AMMONIA-WATER DIFFUSION ABSORPTION REFRIGERATION CYCLE Najjaran A. Freeman J. Ramos A. Markides C.N.* *Author for correspondence Department of Chemical Engineering

More information

MOBA-MATIC AND BIG SONIC-SKI. LEVELING to THE HIGHEST STANDARD

MOBA-MATIC AND BIG SONIC-SKI. LEVELING to THE HIGHEST STANDARD MOBA-MATIC AND BIG SONIC-SKI LEVELING to THE HIGHEST STANDARD MOBA-MATIC THE MOST VERSATILE CONTROL SYSTEM in te world Weter ultrasonic sensor, laser or rotary sensor, MOBA-matic te most flexible control

More information

Global Journal of Engineering Science and Research Management

Global Journal of Engineering Science and Research Management EXPERIMENTAL AND THEORETICAL STUDY OF MINIATURE VAPOR COMPRESSION CYCLE USING MICROCHANNEL CONDENSER Issam M. Ali Aljubury*, Ahmed Q. Mohammed, Marwa S. Neama * Mechanical Eng. Dept. College of Engineering,

More information

(Non-legislative acts) REGULATIONS

(Non-legislative acts) REGULATIONS 12.10.2012 Official Journal of the European Union L 278/1 II (Non-legislative acts) REGULATIONS COMMISSION REGULATION (EU) No 932/2012 of 3 October 2012 implementing Directive 2009/125/EC of the European

More information

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72 International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72 International Journal of Research in Engineering and Innovation (IJREI) journal home page: http://www.ijrei.com

More information

Keywords : Evaporative cooling, Saturation efficiency, Cooling capacity, Cooling pad, Cellulose, Aspen, Coconut coir. IJSER

Keywords : Evaporative cooling, Saturation efficiency, Cooling capacity, Cooling pad, Cellulose, Aspen, Coconut coir. IJSER International Journal of Scientific & Engineering Research, Volume 5, Issue 10, October-2014 676 Performance Evaluation of Alternative Evaporative Cooling Media Rajesh Maurya*, Dr. Nitin Shrivastava, Vipin

More information