1 INSTALLATION MANUAL UltraGRIND Package Systems with Pressure Switches Underwriters Laboratories Inc File No. E IMPORTANT: Read all instructions in this manual before operating pump. As a result of Crane Pumps & Systems, Inc., constant product improvement program, product changes may occur. As such Crane Pumps & Systems, Inc., reserves the right to change product without prior written notification. A Crane Co. Company PUMPS & SYSTEMS 420 Third Street/P.O. Box West Drive, Brampton Piqua, Ohio Ontario, Canada L6T 2J6 Phone: (937) Phone: (905) Fax: (937) Fax: (905) Form No Rev. C

2 TABLE OF CONTENTS USER GUIDE...3 SAFETY FIRST...4 A. GENERAL INFORMATION (Receiving, Storage, Service Centers, Unpacking, Location)...5 B. INSTALLATION (Bedding, Gravel Specifications, Placing into Hole) (Fig. 1, 2 & 3) (Locating and Installing Inlet) (Fig. 4, 5)...6 (Discharge) (Fig. 6) (Incoming Cable Location) (Fig. 7 & 8)...7 (Backfilling) (Fig. 9)...8 (Pump Installation) (Fig. 10 & 11)...8 (Control/Junction Box Connections) (Fig. 12) C. REPLACEMENT PARTS...9 CONTROL/JUNCTION BOX WIRING FOR PRESSURE SWITCHES: Simplex with Temp (Fig. 13)...10 Simplex with Moist/Temp (Fig. 14)...11 Duplex with Temp (Fig. 15)...12 Duplex with Moist/Temp (Fig.16)...13 EXPLODED VIEW - SIMPLEX w/pressure SWITCHES...14 PARTS LIST...15 EXPLODED VIEW - DUPLEX w/pressure SWITCHES...16 PARTS LIST...17 CROSS SECTION - SIMPLEX CONTROL BOX...18 CROSS SECTION - DUPLEX CONTROL BOX...19 DIRECT BURIAL CABLE REQUIREMENTS...20 BASIN VOLUME CHART...21 BASIN BALLAST REQUIREMENTS...22 RETURNED GOODS POLICY...24 WARRANTY Other brand and product names are trademarks or registered trademarks of their respective holders. UltraGRIND is a trademark of Barnes Pumps, Inc. Barnes is a registered trademark of Barnes Pumps, Inc. Barnes Pumps, Inc. 1994, 1997, 2002 Alteration Rights Reserved. Printed in U.S.A. 2

3 USER GUIDE Congratulations on your purchase of a Barnes UltraGRIND grinder pump system. With proper care and by following a few simple guidelines your grinder pump will give you many years of dependable service. Use and Care The UltraGRIND grinder pump station is designed to handle routine, domestic sewage. Solid waste materials should be thrown in the trash. While your station is capable of accepting and pumping a wide range of materials, regulatory agencies advise that the following items should not be introduced into any sewer either directly or through a kitchen waste disposal: Glass Metal Diapers Socks, rags or cloth Plastic objects (e.g., toys, utensils, etc.) Sanitary napkins or tampons In addition you must NEVER introduce into any sewer: Explosives Flammable Material Lubricating Oil and/or Grease Strong Chemicals Gasoline General Information Your home wastewater disposal service is part of a low pressure sewer system. The key element in this system is the Barnes UltraGRIND grinder pump station. The basin collects all wastewater from the house. The solids in the sewage are then ground to a small size suitable for pumping in the slurry. The grinder pump generates sufficient pressure to pump this slurry from your home to the wastewater plant. Power Failure Your grinder pump cannot dispose of wastewater or provide an alarm signal without electrical power. If electrical power service is interrupted, keep water usage to a minimum. Warranty Your grinder pump is furnished with a warranty against defects in material or workmanship. A properly completed Start Up/Warranty Registration form must be on file at the Barnes factory in order to activate your warranty. In addition your pump must be installed in accordance with the installation instructions. If you have a claim under the provisions of the warranty, contact your local Barnes Pumps, Inc. Distributor. When contacting your representative for service, please include your station serial number, pump model number, and pump serial number. For future reference, record the following information: Station Serial No: Pump Model No: Pump Serial No: Local Distributor: Distributor Telephone: 3

4 SAFETY FIRST! PLEASE READ THIS BEFORE INSTALLING OR OPERATING PUMP. GENERAL 1. Most accidents can be avoided by using COMMON SENSE. 2. Read this operation and maintenance instruction manual. 3. Do not wear loose clothing that may become entangled in the impeller or other moving parts. 4. Always wear appropriate safety gear, such as safety glasses, when working on the pump or piping. 5. Bronze/brass and bronze/brass fi tted pumps may contain lead levels higher than considered safe for potable water systems. Various government agencies have determined that leaded copper alloys should not be used in potable water applications. For nonleaded copper alloy materials of construction, please contact factory. 6. Minimize the amount of cooking grease entering the system. 7. Do Not leave pump cover off the basin, except while servicing, to prevent entrance of foreign materials such as rocks, metal, soil, animals or humans. 8. Prevent large articles of clothing, large amounts of chemicals, other materials or substances such as are uncommon in domestic sewage from entering the system. 9. During power black-outs, discontinue water consumption at the home(s) to prevent sewage from backing up into the house. 10. Prevent infi ltration or direct fl ow of rain or run-off water into the pump basin to minimize pump cycling. This will prevent overloading the treatment facility, and will facilitate swift transportation of sewage. 11. Always keep the shut-off valve completely open when system is in operation (unless advised otherwise by the proper authorities). 12. Keep the control panel locked or confi ned to prevent unauthorized access to it. 13. If the pump is idle for long periods of time, it is advisable to start the pump occasionally by adding water to the basin. 14. Before removing the pump from the basin, be sure to close the shut-off valve. (This prevents back fl ow from the pressure sewer.) 15. Make sure level controls are provided at time of installation. 16. This basin system is intended for use with water, sewage and effl uent applications. This basin must be vented in accordance with local codes. This basin system is not to be installed in locations in which the basin interior would be classifi ed as a hazardous location in accordance with NEC ANSI/NPFA 70. PUMPS 17. Recommended no more than 10 starts per hour. 18. Pumps build up heat and pressure during operation-allow time for pumps to cool before handling or servicing. 19. Only qualifi ed personnel should install, operate and repair pump. 20. Keep clear of suction and discharge openings. DO NOT insert fi ngers in pump with power connected. 21. Do not pump hazardous materials (flammable, caustic, etc.) unless the pump is specifically designed and designated to handle them. 22. Do not block or restrict discharge hose, as discharge hose may whip under pressure. 23. Make sure lifting handles are securely fastened each time before lifting. 24. Do not lift pump by the power cord. 25. Do not exceed manufacturers recommendation for maximum performance, as this could cause the motor to overheat. 26. Secure the pump in its operating position so it can not tip over, fall or slide. 27. Keep hands and feet away from impeller when power is connected. 28. Submersible Pumps are not approved for use in swimming pools, recreational water installations, decorative fountains or any installation where human contact with the pumped fl uid is common. 29. Do not operate pump without safety devices in place. 30. Always replace safety devices that have been removed during service or repair. ELECTRICAL 31. To reduce risk of electrical shock, pump must be properly grounded in accordance with the National Electric Code (NEC) and all applicable state and local codes and ordinances. 32. To reduce risk of electrical shock, always disconnect the pump from the power source before handling or servicing. Lock out power and tag. 33. Any wiring of pumps should be performed by a qualifi ed electrician. 34. Never operate a pump with a power cord that has frayed or brittle insulation. 35. Cable should be protected at all times to avoid punctures, cut, bruises and abrasions - inspect frequently. 36. Never handle connected power cords with wet hands. 37. Do not remove cord and strain relief. Do not connect conduit to pump. 38. To reduce risk of electrical shock, all wiring and junction connections should be made per the NEC and applicable state and local codes. Requirements may vary depending on usage and location. See wiring diagrams in manual. 39. Do Not operate the pump in the HAND control position and leave the pump unattended. 40. CAUTION - This unit may have more than one connection to the source of supply. To reduce the risk of electric shock, disconnect all such connections before servicing. 41. All connections inside this tank and/or junction box must be made with listed watertight connectors. IMPORTANT! BARNES PUMPS, INC. IS NOT RESPONSIBLE FOR LOSSES, INJURY, OR DEATH RESULTING FROM A FAILURE TO OBSERVE THESE SAFETY PRECAUTIONS, MISUSE OR ABUSE OF PUMPS OR EQUIPMENT. 4

5 SECTION A: GENERAL INFORMATION A-1) RECEIVING: Upon receiving the Basin Package System, it should be inspected for damage or shortages. If damage has occurred, file a claim immediately with the company that delivered the basin package. A-2) STORAGE: If Basin Packages are going to be stored make sure all outside openings are sealed, i.e. discharge coupling, electrical coupling (if equipped) etc., also secure access door or basin cover. A-3) SERVICE CENTERS: For the location of the nearest Barnes Pumps Service Center, check your catalog, your Barnes Pumps, Inc. representative or Barnes Pumps, Inc. Service Department in Piqua, Ohio, telephone (937) A-4) UNPACKING: Before installing Basin Package remove the tape from all outside openings, discharge coupling, etc. Remove basin cover on simplex or open access door on duplex units being careful not to damage gasket, to unpackage anything that was secured for shipment. A-5) LOCATION: This basin system is intended for use with water and sewage applications. The standard basin is vented, any alterations from the standard must be in accordance with local codes. This basin system is not to be installed in locations in which the basin interior would be classified as a HAZARDOUS location in accordance with NEC ANSI/NFPA 70. GRAVEL SPECIFICATION: 1. A naturally rounded aggregate is required, clean and free flowing with particle size not less than 1/8" or more than 3/4" in diameter. Use this description when specifying or ordering because material is known by different names in different areas. This material is commonly called "pea gravel". 2. Stone or gravel crushing with angular particle size not less than 1/8" or more than 1/2" diameter washed and free flowing is acceptable as an alternate material. This material must meet ASTM C-33 paragraph 9.1 requirements for quality and soundness. B-2) PLACING STATION INTO HOLE: Lifting the basin system, into place should be done with a cloth or nylon type strap around basin or by a lifting harness connected to eyebolts that are set into the concrete pad that is connected to basin by anchor bolts. Never use chain or cable type lifting device around outer basin. This can and may create a fracture in the fiberglass. See Figures 2 and 3. Figure 2 SECTION B: INSTALLATION B-1) BEDDING: Prepare the hole to the proper depth. Add and level bedding of select aggregate (pea gravel-see Gravel Specifications) of 4 to 6 inches or concrete pad or a concrete donut shall be laid before basin is lowered into the ground. The aggregate must conform to the bottom of the basin and reach a compaction of 85% Standard Proctor Density. See Figure 1. Figure 1 Lower the basin, centering it into the hole and orienting it to allow for proper inlet installation. A minimum clearance of 4 to 6 inches should be maintained between the tank wall and the surrounding earth. ALL OSHA PROCEDURES SHOULD BE FOLLOWED REGARDING INSTALLATION OF BASIN. The basin must be leveled after placement to within 1/2 bubble. To prevent the basin from floating upward when the ground water is high, a weight of 63 pounds per cubic foot of basin volume must anchor the basin in place (see "BALLAST REQUIREMENTS" on page 22). This can be done by fastening the ballast support flange to a concrete pad or donut, or by adding the equivalent amount of gravel and/or concrete to the surrounding basin area (surrounding the 2" flange). 5

6 NOTE: Schedule 40 and SDR35 pipe require different sizes of flexible pipe fittings. Check to be sure the inlet pipe matches the flexible pipe fitting supplied. Figure 3 To install the inlet pipe into the flexible pipe fitting, chamfer the end and lube the pipe with soapy water for ease of installation, see Figure 4. An OPTIONAL adapter or caulking hub may be used in place of the flexible pipe fitting. B-3) LOCATING & INSTALLING INLET: B-3.1) FLEXIBLE PIPE FITTING INLET: The flexible pipe fitting for the inlet must be installed. 1. Find the location where the center of the coupling will be positioned on basin. See Fig. 5 for recommended location. 2. Using a HOLE SAW, cut the hole in the basin (DO NOT use a Saber Saw). Refer to the chart below for hole size. 3. Install flexible pipe fitting in the opening. See Figure 4. Figure 5 24" - 30" DIA Simplex Basin 36" And Larger Simplex And All Duplex Basins FIGURE 5 Angle "A" Should Be Between Angle "B" Should Be 45 Maximum. FLEXIBLE PIPE FITTING SIZE 1-1/4 1-1/2 2 Figure 4 HOLE SIZE COLOR CODE 3" Black -40 Black/Red-40 Black/Blue " White " Grey-40, Maroon " Black-40, Yellow-35 B-3.2) Discharge: Connect the sanitary main to the NPT discharge connection located on the outside of the basin (See Figure 6). It is recommended that a shut-off valve, and a redundant check valve be located at the property line near the sanitary main (by others). A flexible pipe coupling should also be installed at the basin. The check valve should be of a flap style able to operate in a horizontal position. It is recommended that in cold regions the piping above the frost grade be insulated. Consult factory for severely cold climates. 6

7 CONTROL/JUNCTION BOX CABLE GRIPS BASIN WALL 6"- 8" Approx. DRIP LOOP Figure 7 CABLE GRIPS DIRECT BURIAL CABLE B-3.3) Control Panel: Next locate and mount electrical control panel, and run wire to the basin package (see Control Panel Manual). CAUTION! ALL MODEL PUMPS AND CONTROL PANELS MUST BE PROPERLY CONNECTED AND PROPERLY GROUNDED PER THE NATIONAL ELECTRICAL CODE, STATE, AND LOCAL CODES. IMPROPER GROUNDING VOIDS WARRANTY. NOTE: A proper motor controller must be provided that is compatible with the pump(s) being installed. (Motor Controller is part of control panel when factory supplied.) B-4) INCOMING CABLE LOCATION: Figure 6 B-4.1) Direct Burial Cable with Cable Grips: Backfill and compact to a convenient level to work around top of basin. Locate and drill holes (see page 20 for hole sizes) for the direct burial cable grips in the basin wall. Holes should be located 18 inches below grade. Feed the direct burial cable through the cable grips and into the junction box and tighten the grips on the box and the basin. It is important to leave enough cable slack between the junction box and basin wall to form a drip loop (see Figure 7). B-4.2) Direct Burial Cable with Conduit Coupling: Backfill and compact to a convenient level to work around top of basin. To install an OPTIONAL conduit coupling (see Figure 8). 1. Find the location where the center of the coupling will be positioned on basin. 2. Using a HOLE SAW, cut the hole in the basin to the outside diameter of the coupling being installed. 3. Place coupling on basin wall and drill mounting holes in basin. 4. Apply gasket or sealing caulk to back of coupling, and mount coupling on basin. 5. Insert bolts, washers and nuts through basin wall and coupling, and tighten. OPTIONAL Conduit Hub Installation: JUNCTION BOX BASIN WALL CABLE GRIPS 6"- 8" Approx. DRIP LOOP Figure 8 DIRECT BURIAL CABLE CONDUIT COUPLING After coupling has been installed, run the direct burial cable through the coupling and into the junction box and tighten the grips on the box. It is important to leave enough cable slack between the junction box and basin wall to form a drip loop (see Figure 8). 7

8 Rope or Chain Figure 10 Figure 9 B-5) Backfill: Finish backfill and compaction (see Figure 9). Place at least 4 inches and preferably 6 inches of aggregate in layers around the entire periphery of the basin in the ground, being careful not to damage or loosen any connections. CAUTION! NOTE: A hoist or crane may be used in lowering and removing the pump. Center the pump under the hook so that the pump can be lifted straight up. Lifting a pump that is not centered will create side pulls which may strain the crane and/or cause the pump to bind in the guide rail. Follow all general precautions in the crane s manual when installing and operating the crane. See Figure 11. IN FREEZING CONDITIONS BACKFILL MUST BE DRY AND FREE OF ICE. DO NOT use backfill materials other than those specified above. In areas where specified materials are not available contact Barnes Pumps, Inc. for information on approved alternate materials. The basin warranty is automatically voided if other than approved bed and backfill materials are employed without advance written approval. B-6) PUMP INSTALLATION: First attach lifting rope or chain to the pump (see Figure 10). Remove basin cover or open access door. Record Pump Model, Part and Serial numbers in Start-Up manual and on User Guide. Rotate pump impeller by hand and then lower pump and movable assembly, utilizing the lifting chain or rope, down the rail slowly (DO NOT DROP!) Observe OSHA recommendations when installing and removing pump. CAUTION! RISK OF ELECTRICAL SHOCK. DO NOT LOWER PUMP BY THE POWER CORD. Figure 11 B-6) CONTROL/JUNCTION BOX CONNECTIONS: IMPORTANT! CHECK TO BE CERTAIN THAT ALL POWER IS OFF. IMPORTANT! ALL CONNECTIONS INSIDE THIS TANK AND/OR JUNCTION BOX MUST BE MADE WITH "UL" LISTED WATER TIGHT CONNECTORS. 8

9 CAUTION! THIS UNIT MAY HAVE MORE THAN ONE CONNECTION TO THE SOURCE OF SUPPLY. TO REDUCE THE RISK OF ELECTRIC SHOCK, DISCONNECT ALL SUCH CONNECTIONS BEFORE SERVICING. Wire Size: Consult a qualified electrician for proper wire size. See Pump Manual for electrical information. Remove junction box cover to connect pump, sensor and control cords to incoming direct burial cables. Refer to Figures 13 through 16. Direct Burial Cable: Due to the availability of multi conductor direct burial cables, several options have been left to the installer (see "DIRECT BURIAL CABLE REQUIREMENTS" on page 20). For OPTIONAL conduit from the basin to the motor controller, it is recommended that a packing material such as a sprayable urethane foam be used in the conduit line, placed around the wires, at the conduit coupling to help prevent gases from entering the motor controller. Packing is recommended for ALL entries into the motor control panel. It is very important to keep the conduit line dry and free from moisture during this process. Reactivation: 1. Turn the control panel breaker to the "ON" position. 2. Test the pump by running manually for 5 to 10 seconds. SECTION: C REPLACEMENT PARTS C-1 ORDERING REPLACEMENT PARTS: When ordering replacement parts, ALWAYS furnish the following information: 1. Serial number and date code. (C-4) 2. Model number. (C-3) 3. Part number. (C-2) 4. Part description. 5. Item part number. 6. Quantity required. 7. Shipping instructions. 8. Billing instructions Figure 12 B-7) WINTERIZATION: 1. Remove the basin cover. 2. Manually pump the station fluid level down to the normal "OFF" level. Do not pump below the suction entrance of the pump. 3. Add fresh fluid until pump automatically turns "ON". Repeat until most of the sewage has been pumped out. 4. With the fluid level in the basin at the normal "OFF" position, add an equal amount of propylene glycol (non-toxic) to the basin. Mix by closing discharge valve and allow pump to run for one (1) minute. 5. Run the pump for 5 to 10 seconds to add winterized fluid to the discharge lines. 6. Reinstall the basin cover. 7. Turn the control panel breaker to the "OFF" position. C-2 PART NUMBER: The part number consists of a six (6) digit number, which appears in the catalog. A one or two letter suffix may follow this number to designate the design configuration. This number is used for ordering and obtaining information. C-3 MODEL NUMBER: This designation consists of numbers and letters which represent the diameter, depth and design. This number is used for ordering and obtaining information. C-4 SERIAL NUMBER: The serial number block will consist of a six digit number, which is specific to each unit and may be preceded by an alpha character, which indicates the plant location. This number will also be suffixed with a four digit number, which indicates the date the unit was built (Date Code). EXAMPLE: A Reference the six digit portion (Serial Number) of this number when referring to the product. 9

10 Simplex Pressure Switch - 2, 3, 5,& 7.5HP Grinder with Pump Cable and 14/2 Sensor Cable. Figure 13 10

11 Simplex Pressure Switch - 2, 3, 5,& 7.5HP Grinder with Pump Cable and 18/5 Sensor Cable. Figure 14 11

12 Duplex Pressure Switch - 2, 3, 5,& 7.5HP Grinder with Pump Cable and 14/2 Sensor Cable. Figure 15 12

13 Duplex Pressure Switch - 2, 3, 5,& 7.5HP Grinder with Pump Cable and 18/5 Sensor Cable. Figure 16 13

14 SIMPLEX - PRESSURE SWITCHES 14

15 SIMPLEX - PRESSURE SWITCHES or UltraSWITCH REPAIR KITS UltraSWITCH For SGV Pumps...P/N: UltraSWITCH For SGPC Pumps...P/N: PARTS LIST IMPORTANT! Specify Package Model Number & Part Number when ordering parts or service inquiries. ITEM QTY. DESCRIPTION 1 1 Basin 2 1 Basin Cover 3 12 Cap Screw 3/8-16 x 1.25" Lg Stainless 4 12 Flat Washer 1" O.D. x 3/8" I.D. Stainless 5 6 Lock Washer 3/8" Stainless 6 6 Hex Nut 3/8-16 Stainless 7 1 Discharge Coupling 8 4 Lock Washer 3/4" O.D. x 3/8" I.D. Stainless 9 4 Hex Nut 5/16-18 Stainless 10 1 Gasket, Discharge Buna-N 11 1 Stainless "C" Channel: (Must use Rail Extensions for deeper Basins.) 12 2 Right Brace, Stainless 13 2 Left Brace, Stainless 14 1 True Union Ball Valve 15 1 Extension Handle 16 1 Close Nipple 17 1 Stationary Fitting 18 1 Diaphragm 19 8 Lock Washer, Internal Tooth No. 10, Stainless 20 8 Hex Nut 10-32, Stainless 21 1 Lifting Device (Not Shown) Polypropylene Rope, Stainless Cable, Steel Chain 22 1 Mounting Bracket (Included with #29) Stainless 23 1 Cover Gasket 28 1 J-Bolt Stainless 29 1 Juction Box (For UltraSWITCH ) 30 1 UltraSWITCH 32 1 Extention Handle Bracket 33 1 Nipple 34 1 Serial Plate 35 2 Cap Screw 37 8 Sealing Washer 3/8" 38 1 Bug Free Vent 2" 40 1 Vent Flange, 2" Strain Relief Cable Grip (STD) Electrical Coupling 1.50" (OPTIONAL) Electrical Coupling 2.00" (OPTIONAL) 42 2 Hex Hd Screw 3/8-16 x 1-1/2" Lg. Stainless 43 2 Lock Washer 3/8" Stainless 44 1 Inlet, Flexible Pipe Fitting 4" Sch. 40 PVC 4" SDR 35, PVC (STD) 6" Sch. 40 PVC 6" SDR 35, PVC 45 1 Close Nipple 2", NPT, Stainless 46 8 Hex Hd Screw 5/16-18 x 1-1/4" Lg, Stainless 48 4 Hex Hd Screw 1/4-20 x.75" Lg, Stainless 49 4 Lockwasher 1/4", Stainless 50 4 Hex Nut 1/4-20, Stainless 51 2 U-Bolt 2.50" Stainless 15

16 DUPLEX - PRESSURE SWITCHES 16

17 DUPLEX - PRESSURE SWITCHES or UltraSWITCH REPAIR KITS UltraSWITCH For SGV Pumps...P/N: UltraSWITCH For SGPC Pumps...P/N: PARTS LIST IMPORTANT! Specify Package Model Number & Part Number when ordering parts or service inquiries. ITEM QTY. DESCRIPTION PART No. 1 1 Basin Various Depths & Diameters 2 1 Basin Cover, One Piece 36" Dia. Basin, Fiberglass Basin Cover, w/access Door 36" Dia. Basin, Steel " Dia. Basin, Steel " Dia. Basin, Steel " Dia. Basin, Steel " Dia. Basin, Aluminum "Dia. Basin, Aluminum "Dia. Basin, Aluminum "Dia. Basin, Aluminum Cap Screw 3/8-16 x 1.25" Lg Stainless Flat Washer 1" O.D. x 3/8" I.D. Stainless Lock Washer 3/8" Stainless Hex Nut 3/8-16 Stainless Discharge Coupling For 36" Dia. Basin Only " NPT, Stainless " NPT, Stainless Lock Washer 3/4" O.D. x 3/8" I.D. Stainless Hex Nut 5/16-18 Stainless Cap Plug (For Shipping Only) Stainless "C" Channel 48" Basin Depth " Basin Depth " Basin Depth " Basin Depth " Basin Depth " Basin Depth " Basin Depth " Basin Depth " Basin Depth " Basin Depth " Basin Depth (Must use Rail Extensions for deeper Basins) 12 2 Right Brace, Stainless 36" Dia. Basin " Dia. Basin A 48" Dia. Basin B 60" Dia. Basin C 72" Dia. Basin Left Brace, Stainless 36" Dia. Basin " Dia. Basin A 48" Dia. Basin B 60" Dia. Basin C 72" Dia. Basin True Union Ball Valve 1.25" NPT, PVC " NPT, PVC Extension Handle 48" Deep " Deep " Deep " Deep " Deep " Deep " Deep " Deep " Deep " Deep Pipe Nipple 1.25" NPT x Close, Stainless " NPT x Close, PVC " NPT x Close, Stainless " NPT x Close, PVC

18 SIMPLEX - CONTROL BOX w/pressure SWITCHES PARTS LIST Parts Kit*...P/N: IMPORTANT! Specify Package Model Number & Part Number when ordering parts or service inquiries. ITEM QTY. DESCRIPTION 1 1 * Pressure Switch Pump ON 2 1 * Pressure Switch Pump OFF 3 1 * Pressure Switch HI-LEVEL 4 1 NEMA 6 Enclosure 5 1 Heater 6 2 * Tee Union, Comp., Brass 7 1 Reducer, Brass.50 x Pipe, PVC,.50" Sch * Elbow, Comp. 1/8" NPT, Brass * Tubing.170 ID x.250 OD, Vinyl 11 1 Coin Plug (Use as required) Cord Grip, Valox 13 3 Cord Grip, Valox 14 1 * Bracket, Stainless 15 1 Mounting Bracket, Stainless 16 2 SKHD Screw #8-32 x.625, Stainless 17 1 Male Connector.50" Sch. 40, PVC 18 2 O-Ring 20 1 Reducer 4" x 2", PVC 21 1 Reducer Bushing 2-1/2", PVC 22 3 * Nut , Brass 30 4 Coin Plug 31 1 Cord Grip, Valox 32 1 Flat Washer, Stainless * Lock Washer, Ext. 7/16, ZP 18

19 DUPLEX - CONTROL BOX w/pressure SWITCHES PARTS LIST Parts Kit*...P/N: IMPORTANT! Specify Package Model Number & Part Number when ordering parts or service inquiries. ITEM QTY. DESCRIPTION 1 1 * Pressure Switch Pump 1 ON 2 1 * Pressure Switch Pumps OFF 3 1 * Pressure Switch Pump 2 ON 4 1 * Pressure Switch Hi-Level Alarm 5 1 NEMA 6 Enclosure 6 1 Heater Assy 7 3 * Tee Union, Barb, Brass 8 1 Reducer, Brass.50 x Pipe, PVC,.50 Sch Reducer, Barb, Brass 1/8 x * Tubing, Vinyl.170 ID x.25 OD 13 2 Cord Grip, Valox 14 4 Cord Grip, Valox 15 1 * Bracket, Switch, Stainless 16 1 Mounting Bracket 17 4 Cord Grip, Valox 18 1 Male Connector.50", Sch Connector Nut 21 1 Reducer, PVC 4" x 2" 22 1 Reducer Bushing, PVC 2-1/2" 28 2 Hex Screw 5/16 x.75" Lg, Stainless 29 2 Hex Nut 5/16-18, Stainless 32 1 Flat Washer Stainless 33 8 Coin Plug (Use as required) 34 2 Coin Plug (Use as required) * Lock Washer 7/16", ZP 19

20 DIRECT BURIAL CABLE REQUIRMENTS For *Wall Mount Control Panels. CONTROL PANEL SERIES 101, 102, 102B, 105, 106, 109, 110, 113, 114 UGP CONTROL CABLE SIZE UCP CONTROL CABLE SIZE SIMPLEX + NUMBER CONTROL CABLES UGP POWER CABLE SIZE UCP POWER CABLE SIZE 18/8 18/6 1 10/4 12/3 (230V) 10/3 (115V) NUMBER POWER CABLES PUMP CONTROL (SGV) 1 Temp Sensor 103, 104, 107, 108, 111, 112, 115, /10 18/6 1 10/4 12/3 (230V) 10/3 (115V 1 Temp Sensor, Moisture Sensor 201, 202, 205, 206, 209, 210, 213, 214 DUPLEX 18/12 18/8 1 10/4 12/3 (230V) 10/3 (115V 2 Temp Sensor 203, 204, 207, 208, 210, 212, 215, /6 18/8 3 (SGV) 1 (SGPC) 10/4 12/3 (230V) 10/3 (115V 2 Temp Sensor Moisture Sensor CABLE DESCRIPTION; Ref. NEC article #340 Type TC (ROUND) tray cable, THHN or THWN (TFFN) UL recognized, direct burial cable. Volts, rated 600V continuous use at 90C dry and 75C wet. Cable to meet requirements of UL83 for THHN or THWN. Jacket to be printed or indented, size and number of conductors THHN or THWN (TFFN) type TC 600V (UL). * For Convertable Cover, 1-10/5 DBC required for UGP 1-12/5 for UCP 230 Volt Panels, 1-10/4 DBC required for UCP 115 Volt. THROUGH BASIN WALL USE CABLE PART NUMBER GRIP RANGE CORD GRIP # LOCK NUT DRILL SIZE 10/ /8" 10/ /8" 10/ " 12/ /8" 12/ /8" 18/ /8" 18/ /8" 18/ /8" 18/ /8" 18/ " Required from home to control panel: 10/4 (3 power 1 ground) and 30 Amp breaker at the service drop. 20

21 BASIN VOLUME CHART IN U.S. GALLONS SIZE Dia X Ht VOLUME GALLONS VOLUME "OFF" VOLUME "ON" VOLUME "ALARM" VOLUME BETWEEN ON - OFF 24 x x " " " " 24 x " " " " 24 x " " " " 24 x " " " " 24 x " " " " 24 x " " " " 24 x " " " " 24 x " " " " 24 x " " " " 30 x x " " " " 30 x " " " " 30 x " " " " 30 x " " " " 30 x " " " " 30 x " " " " 30 x " " " " 30 x " " " " 30 x " " " " 36 x x " " " " 36 x " " " " 36 x " " " " 36 x " " " " 36 x " " " " 36 x " " " " 36 x " " " " 36 x " " " " 36 x " " " " 36 x " " " " 36 x " " " " 42 x x " " " " 42 x " " " " 42 x " " " " 42 x " " " " 42 x " " " " 42 x " " " " 42 x " " " " 42 x " " " " 42 x " " " " 48 x x " " " " 48 x " " " " 48 x " " " " 48 x " " " " 48 x " " " " 48 x " " " " 48 x " " " " 48 x " " " " 48 x " " " " 60 x x " " " " 60 x " " " " 60 x " " " " 60 x " " " " 60 x " " " " 60 x " " " " 60 x " " " " 60 x " " " " 60 x " " " " 72 x NOTES: 1) Pump will displace approximately 3.3 gallons. 2) Ref. 1 gallon = x height (inches) x diameter (inches). 21

22 BASIN BALLAST REQUIREMENTS 63 LB. PER CUBIC FOOT OF VOLUME REQUIRED SIZE Dia X Ht BASIN VOLUME CU. FT. REQUIRED BALLAST LBS. REQUIRED BALLAST CU. FT. 24 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x NOTES: 1) Gallons x.1337 = cu. ft. 2) One cu. ft. ballast = 140 lbs. 22

23 NOTES: 23

24 IMPORTANT! WARRANTY REGISTRATION Your product is covered by the enclosed Warranty. Complete the Warranty Registration Form and returned to Crane Pumps & Systems, Inc. Warranty Service Group IMPORTANT! If you have a claim under the provision of the warranty, contact your local Crane Pumps & Systems, Inc. Distributor. RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A "RETURNED GOODS AUTHORIZATION". CONTACT YOUR LOCAL CRANE PUMPS & SYSTEMS, INC. DISTRIBUTOR. Products Returned Must Be Cleaned, Sanitized, Or Decontaminated As Necessary Prior To Shipment, To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material. All Applicable Laws And Regulations Shall Apply. 24

25 Limited 1 Year Warranty We warrant to our immediate customer and to the ultimate consumer that products of our manufacture will be free of defects in material and workmanship under normal use and service for the following time periods, when installed and maintained in accordance with our instructions. Twelve (12) months after notice of owner s acceptance, but no greater than twenty-four (24) months after receipt of shipment. As used herein, "the ultimate consumer" is defined as the purchaser who first uses the product after its initial installation It is the purchaser s or any sub-vendee s obligation to make known to the ultimate consumer the terms and conditions of this warranty. This warranty gives you specific legal rights, and there may also be other rights which vary from state to state. In the event the product is covered by the Federal Consumer Product Warranties Law (1) the duration of any implied warranties associated with the product by virtue of said law is limited to the same duration as stated herein, (2) this warranty is a LIMITED WARRANTY, and (3) no claims of any nature whatsoever shall be made against us, until the ultimate consumer, his successor, or assigns, notifies us in writing of the defect, and delivers the product and/or defective part(s) freight prepaid to our factory or nearest authorized service station. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply. THE SOLE AND EXCLUSIVE REMEDY FOR BREACH OF ANY AND ALL WARRANTIES WITH RESPECT TO ANY PRODUCT SHALL BE TO REPLACE OR REPAIR AT OUR ELECTION, F.O.B. POINT OF MANUFACTURE OR AUTHORIZED REPAIR STATION, SUCH PRODUCTS AND/OR PARTS AS PROVEN DEFECTIVE. THERE SHALL BE NO FURTHER LIABILITY, WHETHER BASED ON WARRANTY, NEGLIGENCE OR OTHERWISE. Unless expressly stated otherwise, guarantees in the nature of performance specifications furnished in addition to the foregoing material and workmanship warranties on a product manufactured by us, if any, are subject to laboratory tests corrected for field performance. Any additional guarantees, in the nature of performance specifications must be in writing and such writing must be signed by our authorized representative. Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user, and laboratory tests corrected for field performance, the latter shall control. Components or accessories supplied by us but manufactured by others are warranted only to the extent of and by the terms and conditions of the original manufacturer s warranty. RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS ANALYSES AND EVALUATIONS WE CONDUCT WILL BE BASED ON OUR BEST AVAILABLE EXPERIENCE AND PUBLISHED INDUSTRY INFORMATION. SUCH RECOMMENDATIONS DO NOT CONSTITUTE A WARRANTY OF SATISFACTORY PERFORMANCE AND NO SUCH WARRANTY IS GIVEN. This warranty shall not apply when damage is caused by (a) improper installation, (b) improper voltage (c) lightning (d) sand or other abrasive material (e) scale or corrosion build-up due to excessive chemical content. Any modification of the original equipment will also void the warranty. We will not be responsible for loss, damage or labor cost due to interruption of service caused by defective parts. Neither will we accept charges incurred by others without our prior written approval. This warranty is void if our inspection reveals the product was used in a manner inconsistent with normal industry practice and\or our specific recommendations. The purchaser is responsible for communication of all necessary information regarding the application and use of the product. UNDER NO CIRCUMSTANCES WILL WE BE RESPONSIBLE FOR ANY OTHER DIRECT OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LOST PROFITS, LOST INCOME, LABOR CHARGES, DELAYS IN PRODUCTION, IDLE PRODUCTION, WHICH DAMAGES ARE CAUSED BY ANY DEFECTS IN MATERIAL AND\OR WORKMANSHIP AND\OR DAMAGE OR DELAYS IN SHIPMENT. THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY OTHER EXPRESS OR IMPLIED WARRANTY, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. No rights extended under this warranty shall be assigned to any other person, whether by operation of law or otherwise, without our prior written approval. PUMPS & SYSTEMS A Crane Co. Company 420 Third Street/P.O. Box West Drive, Brampton Piqua, Ohio Ontario, Canada L6T 2J6 Phone: (937) Phone: (905) Fax: (937) Fax: (905)

26 Barnes Pressure Sewer Systems Piqua, Ohio

BARNES. INSTALLATION MANUAL Basin Package System with Float Switches

BARNES. INSTALLATION MANUAL Basin Package System with Float Switches BARNES INSTALLATION MANUAL Basin Package System with Float Switches IMPORTANT: Read all instructions in this manual before operating pump. As a result of Crane Pumps & Systems, Inc., constant product improvement

More information

SUBMERSIBLE SEWAGE PUMP. Automatic and manual models. Single phase power only 115 or 230 volt.

SUBMERSIBLE SEWAGE PUMP. Automatic and manual models. Single phase power only 115 or 230 volt. MW50 SERIES SUBMERSIBLE SEWAGE PUMP INSTALLATION AND SERVICE MANUAL Automatic and manual models. Single phase power only 115 or 230 volt. NOTE! To the installer: Please make sure you provide this manual

More information

SX SERIES (Class I, Division 1, Group D) INSTALLATION AND SERVICE MANUAL

SX SERIES (Class I, Division 1, Group D) INSTALLATION AND SERVICE MANUAL The submersible SX Series pumps are CSA approved for use in Class I, Division 1, Group D hazardous locations in wastewater and storm water applications. The SX Series pumps are not intended for applications

More information

STATION MODEL: KPCG21-24x48 PUMP MODEL: KEEN KPCG21 VOLTAGE: 230 PHASE: 1 TANK DIMENSIONS: 24 DIAMETER X 48 DEEP

STATION MODEL: KPCG21-24x48 PUMP MODEL: KEEN KPCG21 VOLTAGE: 230 PHASE: 1 TANK DIMENSIONS: 24 DIAMETER X 48 DEEP STATION MODEL: KPCG21-24x48 PUMP MODEL: KEEN KPCG21 VOLTAGE: 230 PHASE: 1 TANK DIMENSIONS: 24 DIAMETER X 48 DEEP PUMP Grinder Pumps KPCG-21 1HP Dual Seal, High Performance Progressive Cavity Grinder Pump,

More information

55-Gallon Dispenser Package

55-Gallon Dispenser Package INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 308 666 Rev. A Husky 715 55-Gallon Dispenser Package 100 psi (6.9 bar) Maximum

More information

Pump Installation and Service Manual SPX50/SPX50H Submersible Explosion-Proof Pumps

Pump Installation and Service Manual SPX50/SPX50H Submersible Explosion-Proof Pumps Pump Installation and Service Manual SPX50/SPX50H Submersible Explosion-Proof Pumps R NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible

More information

User s Manual and Operating Instructions

User s Manual and Operating Instructions User s Manual and Operating Instructions Model Numbers: CL-30P-DDF, CL-20F-DDF, CL-24O-DDF, CL-30-DDF READ AND SAVE THESE INSTRUCTIONS IMPORTANT: Read and understand all of the directions in this manual

More information

BUNN H5E H5M H5X BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217)

BUNN H5E H5M H5X BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217) ! BUNN DISCONNECT FROM POWER SOURCE BEFORE REMOVAL OF ANY PANEL OR REPLACEMENT OF ANY COMPONENT! WARNING H5E H5M H5X WARNING Very Hot Water Use With Care!! ILLUSTRATED PARTS CATALOG Designs, materials,

More information

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. U.S.A. WARNING FOR YOUR

More information

Engineered Basins Affordable, effective pressure sewer system Rocky, hilly, wet and flat topography Dependable, reliable and cost effective

Engineered Basins Affordable, effective pressure sewer system Rocky, hilly, wet and flat topography Dependable, reliable and cost effective brands you trust. Engineered Basins Affordable, effective pressure sewer system Rocky, hilly, wet and flat topography Dependable, reliable and cost effective ENGINEERED BASIN SERIES Barnes Pressure Sewer

More information

Operating Instructions & Parts Manual Models 99533, 99532

Operating Instructions & Parts Manual Models 99533, 99532 Operating Instructions & Parts Manual Models 99533, 99532 2 Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters 1200 North Main Street Fostoria, OH 44830 Phone: 800-495-4525 Fax: 419-435-0842 A DIVISION OF www.fostoriaindustries.com OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters *EXCLUDING

More information

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg. The Extraordinaire Orbital Fan WARNING: Support Directly From Building Structure Net Weight 14.5 lbs. or 6.59 kg. Model No. OF110** OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Important Safety Instructions

More information

INSTALLATION, OPERATION AND MAINTENANCE

INSTALLATION, OPERATION AND MAINTENANCE INLINE HEATER INSTALLATION, OPERATION AND MAINTENANCE MODELS: ILS SERIES 1.5kW 120V SINGLE PHASE BEFORE YOU BEGIN CHECK ALL ELECTRICAL CONNECTIONS TO ALL COMPONENTS WITHIN THE HEATER FOR TIGHTNESS. CONNECTIONS

More information

INSTALLATION AND SERVICE MANUAL WHR5H, 10H, 15H, 20H Series Submersible Sewage Pumps

INSTALLATION AND SERVICE MANUAL WHR5H, 10H, 15H, 20H Series Submersible Sewage Pumps INSTALLATION AND SERVICE MANUAL WHR5H, 10H, 15H, 20H Series Submersible Sewage Pumps 293 WRIGHT STREET, DELAVAN, WI 53115 WWW.femyers.COM PH: 888-987-8677 2013 Pentair All Rights Reserved. 23833A551 (09/23/13)

More information

MODEL SRA(X)-125 COMPLETE GRINDER PACKAGE SYSTEM INSTALLATION AND SERVICE MANUAL. For MG, WG, WGL, WGX and V 2

MODEL SRA(X)-125 COMPLETE GRINDER PACKAGE SYSTEM INSTALLATION AND SERVICE MANUAL. For MG, WG, WGL, WGX and V 2 MODEL SRA(X)-5 COMPLETE GRINDER PACKAGE SYSTEM INSTALLATION AND SERVICE MANUAL For MG, WG, WGL, WGX and V NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment

More information

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product. STOP Power supply required Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-742-5044, 7:30 a.m. - 5 p.m., EST, Monday - Friday. 115 volts

More information

24 & 30 Quiet Design Oscillating Wall Mount Fan

24 & 30 Quiet Design Oscillating Wall Mount Fan Operating Instructions & Parts Manual Models: 99538, 99539 Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

Service Parts, Kits and Accessories

Service Parts, Kits and Accessories The parts identification guides on the following pages have been designed to give a quick reference to component parts used on pilot ignition agricultural building heaters. The guides identify components

More information

MaxLite LED Round Pendant Highbay Series

MaxLite LED Round Pendant Highbay Series General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information

Air Pump Up to 800 gallons

Air Pump Up to 800 gallons Air Pump Up to 800 gallons REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. PACKAGE CONTENTS ITEM #PBPAPK40W Questions, problems, missing parts? Before returning to your retailer, call our customer

More information

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters TPI Corporation P.O. Box 4973 Johnson City, TN 37601 www.tpicorp.com OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters *EXCLUDING RESIDENCES IMPORTANT SAFETY INFORMATION INSIDE possible

More information

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax SPA BLOWER OWNER'S MANUAL 80015-XXXX, 80016-XXXX, 80017-XXXX, 80018-XXXX, 80019-XXXX, 80020-XXXX fax 888.610.3839 2015 323300-015 6/15 THIS PAGE INTENTIONALLY LEFT BLANK. 2 Operating Instructions and Parts

More information

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump Page 1 of 8 biohazard risk exists. Installer(s) and/or service personnel must use proper Personal Protective Equipment and follow handling procedures

More information

User s Manual and Operating Instructions

User s Manual and Operating Instructions User s Manual and Operating Instructions Model Numbers: PT-18W-DDF-A, PT-20F-DDF-A, PT-20S-DDF, PT-24O-DDF, PT-24-DDF, PT-24-DDF-F, PT-30-DDF, PT-30P-DDF-A, PT-30P-DDF-AF READ AND SAVE THESE INSTRUCTIONS

More information

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit January 2008 WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit Installation Operation Maintenance The units are designed for permanent up flow, counter flow, or horizontal left or right airflow

More information

TUBULAR LLdia-PUMPyy INSTRUCTIONS

TUBULAR LLdia-PUMPyy INSTRUCTIONS TUBULAR LLdia-PUMPyy INSTRUCTIONS MODELS 515 to 547 MODELS 560,562,565 and 567 MATERIAL CODES N3, N5 and N7 ADDENDUM TO OPERATING AND INSTRUCTION MANUAL FOR 500 dia-pumps and FOR 560 dia-puws,these Instructions

More information

Professional Plumbing brands you trust.

Professional Plumbing brands you trust. Professional Plumbing brands you trust. PLUMBING SUPPLY PRODUCTS Plumbing Supply Products Sump Pumps Submersible pumps for general purpose residential, commercial and light industrial sump applications.

More information

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Manufactured by SJE-Rhombus Installation Instructions and Operation/Troubleshooting Manual 7000 Apple Tree Avenue Bergen, New York 14416 Phone:

More information

Please Read and Save These Instructions.

Please Read and Save These Instructions. Page 1 of 8 RadonAway Ward Hill, MA. GP500 Fan Installation Instructions Please Read and Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL SERVICE

More information

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 637 Louisville,

More information

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS CAUTION RISK OF INJURY! READ MANUAL BEFORE OPERATING! This manual is an important part of the Corona Discharge Ozone Generator and must remain

More information

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats. Three Phase Simplex Installation Instructions and Operation/Troubleshooting Manual This control panel must be installed and serviced by a licensed electrician in accordance with the National Electric Code

More information

60In. Ceiling Fan. Owner s Manual

60In. Ceiling Fan. Owner s Manual 60In. Ceiling Fan Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may

More information

Installation Instructions PP-AS20 Anti-Scale System

Installation Instructions PP-AS20 Anti-Scale System Installation Instructions PP-AS20 Anti-Scale System THIS UNIT MUST BE INSTALLED BY A LICENSED PLUMBER TO VALIDATE THE WARRANTY. COMPONENTS PP-AS20 Filter Housing PP-AS20R Filter Cartridge Installation

More information

QUICK PRIME INSTALLATION AND SERVICE MANUAL

QUICK PRIME INSTALLATION AND SERVICE MANUAL QUICK PRIME INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system. Part #

More information

IN020 Rev F Page 1 of 8

IN020 Rev F Page 1 of 8 IN020 Rev F Page 1 of 8 RadonAway Ward Hill, MA. Series Fan Installation Instructions Please Read and Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL

More information

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION G Series (Model B) Convector Heater for Hazardous Locations Type G-Series Convection Heaters are designed for use in Class I, Div. I hazardous environments. Units without control options are suitable for

More information

SJE-Rhombus Type IFS w/c-level Sensor Installation Instructions and Operation/Troubleshooting Manual

SJE-Rhombus Type IFS w/c-level Sensor Installation Instructions and Operation/Troubleshooting Manual Installer Friendly Series SJE-Rhombus Type IFS w/c-level Sensor Installation Instructions and Operation/Troubleshooting Manual This control panel must be installed and serviced by a licensed electrician

More information

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3 SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3 READ THESE INSTRUCTIONS BEFORE PLANNING YOUR INSTALLATION PLEASE READ AND SAVE THESE INSTRUCTIONS: DO NOT CONNECT POWER

More information

INTERMEDIATE GUIDE BRACKET

INTERMEDIATE GUIDE BRACKET BAIL ASSEMBLY AND CHAIN TOP RAIL SUPPORT SIDE MOUNT RAIL SUPPORT INTERMEDIATE GUIDE BRACKET LIFT-OUT RAIL SYSTEM 4" & 6" LIFT-OUT RAIL SYSTEMS INSTALLATION MANUAL WITH REPAIR PARTS LIST NOTE! To the installer:

More information

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual SOLARHOT SuperVox Installation/ Owner s Manual Description / Applications System Overview The SOLARHOT SuperVox solar thermal glycol system. The SuperVox allows for easy installation of large solar water

More information

CPL Series Pedestal Convection Heater

CPL Series Pedestal Convection Heater Installation Instructions and RENEWAL PARTS IDENTIFICATION CPL Series Pedestal Convection Heater MODEL CPLAS (H=5-1/2, D=3 ) CAT. LENGTH WATTS/ TOTAL AMPERAGE NO.* L Ft. WATTS 120V 208V 240V 277V 2125

More information

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST SCX1740 SERIES CENTRIFUGAL PUMP High Head - Noryl Impellers MODELS Model ODP MOTORS TEFC MOTORS HP Number 115/230/60/1 20-230/460/60/3

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS VARIABLE SPEED BOOSTER PUMP IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INFORMATION WARNING: RISK OF ELECTRICAL SHOCK

More information

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included F3610G FMI PRODUCTS, LLC 36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included FMI Products, LLC TABLE OF CONTENTS Safety Information... 3 Operating Instructions...

More information

QUICK PRIME INSTALLATION AND SERVICE MANUAL

QUICK PRIME INSTALLATION AND SERVICE MANUAL QUICK PRIME INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system. Part #

More information

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX: ACORN SAFETY P.O. BOX 3527 CITY OF INDUSTRY, CA 91744-0527 UNITED STATES OF AMERICA WWW.ACORNSAFETY.COM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS ELECTRIC ALARM WITH LIGHT AND HORN Model: S0000-AL2-C1D1-DB1

More information

IN-GROUND SUBWOOFER INSTRUCTION MANUAL LS12T SUB LS15T SUB

IN-GROUND SUBWOOFER INSTRUCTION MANUAL LS12T SUB LS15T SUB IN-GROUND SUBWOOFER INSTRUCTION MANUAL LS12T SUB LS15T SUB Introduction Thank you for purchasing a SLS Subwoofer. When properly installed, this subwoofer will provide you with years of outdoor entertainment

More information

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual 8 Vanguard Belt Drive Fans Installation and Operators Instruction Manual Thank You The employees of Chore-Time Equipment would like to thank your for your recent Chore-Time purchase. If a problem should

More information

IMPORTANT SAFETY INFORMATION

IMPORTANT SAFETY INFORMATION OPERATION INSTALLATION PARTS MANUAL www.fostoriaindustries.com Made in U.S.A. ELECTRIC PORTABLE HEATER FES-1024-1CA 08860010 YES-1024-1CA 08861510 FES-1520-3A 08860110 YES-1520-3A 08860810 FES-1524-1A

More information

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE

More information

Xaact Spot. Xaact Hot Spot

Xaact Spot. Xaact Hot Spot Xaact Spot & Xaact Hot Spot INFORMATION & OPERATING INSTRUCTIONS READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE 78-00012 Rev. 101211 1 CONTENTS: Machine Specifications............

More information

COMPLETE GRINDER PACKAGE OFFERING Model TL-PRO SYSTEM

COMPLETE GRINDER PACKAGE OFFERING Model TL-PRO SYSTEM Installation and Service Manual COMPLETE GRINDER PACKAGE OFFERING Model TL-PRO SYSTEM NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl125rok Item Stock Number(s): BFL125ROK IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL,

More information

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual 8 Vanguard Belt Drive Fans Installation and Operators Instruction Manual Thank You The employees of Chore-Time Equipment would like to thank your for your recent Chore-Time purchase. If a problem should

More information

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

IMPORTANT INFORMATION - PLEASE READ CAREFULLY Honeywell Garrett Direct Fit Performance Intercooler 2015+ 3.5L / 2.7L Ford F150 EcoBoost Bill of Materials and Precautions Application: 2015+ Ford F150 3.5L / 2.7L Eco Boost Part Number: 870702-6001 Part

More information

B.I.C.A Built-In Coffee Appliance

B.I.C.A Built-In Coffee Appliance B.I.C.A Built-In Coffee Appliance Automatic Coffee Brewer Parts & Service Models: 1033510, 1033510S & 1033511 3828 S. Main St. Los Angeles, CA 90037-1491 800-421-6860 310-787-5444 Fax 310-787-5412 e-mail:

More information

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

IMPORTANT INFORMATION - PLEASE READ CAREFULLY Honeywell Garrett Direct Fit Performance Intercooler 2015+ 3.5L / 2.7L Ford F150 EcoBoost Bill of Materials and Precautions Application: 2015+ Ford F150 3.5L / 2.7L Eco Boost Part Number: 870702-6001 Part

More information

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE XAACT Xtract 200 INFORMATION & OPERATING INSTRUCTIONS READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE 78-00018 Rev B 032912 1 CONTENTS: Machine Specifications............ 2 Record Important

More information

TWIN-FLOIII HEATER INSPECT THE SHIPMENT IMMEDIATELY WHEN RECEIVED TO DETERMINE IF ANY DAMAGE HAS OCCURRED DURING SHIPMENT.

TWIN-FLOIII HEATER INSPECT THE SHIPMENT IMMEDIATELY WHEN RECEIVED TO DETERMINE IF ANY DAMAGE HAS OCCURRED DURING SHIPMENT. TFII-11 Beacon/Morris TWIN-FLOIII HEATER INSTALLATION INSTRUCTIONS TYPES K, W, & F ATTENTION: READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE, OR SERVICE THE BEACON MORRIS TWIN-FLO

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Product Preservers Anti-Scale System Chemical-Free, Salt-Free Scale Prevention Introduction The Product Preservers Anti-Scale System will condition the tap

More information

Industrial Vacuums, Inc

Industrial Vacuums, Inc Instructions/Spare Parts Manual Nilfisk Model GWD255 Drum Top Vacuum CAUTION: This Nilfisk vacuum cleaner is not to be used in explosion-hazardous areas, as serious injury could result. Under no circumstances

More information

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR Model 91797 ASSEMBLY and Operating Instructions Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure

More information

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels Installation Instructions For the 18 Built-In Dishwasher and Front Color Panels Printed in USA 154232102 Before You Begin DO NOT INSTALL DISHWASHER UNTIL YOU HAVE READ ALL INSTRUCTIONS. FOR YOUR SAFETY,

More information

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- 8610 Production Avenue San Diego, California 92121 (858) 566-7465 Fax (858) 566-1943 WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- Thank you for choosing a BREEZAIRE cooling unit. We believe

More information

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG) WET/DRY VACUUM Operating Instructions (ENG) MODEL: T1 y QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO 9001. Read these instructions before operating the machine.

More information

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop Instruction Manual Cheddar Easy All-In-One Cheese Corn Shop Model No. 2703-00-000 10700 Medallion Drive, Cincinnati, Ohio 45241-4807 USA 2017 Gold Medal Products Co. Part No. 110028 SAFETY PRECAUTIONS

More information

55-Gallon Dispenser Package

55-Gallon Dispenser Package INSTRUCTIONS-PARTS LIST Husky 515 55-Gallon Dispenser Package 08666 Rev.C INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 100 psi(6.9 bar) Maximum Air

More information

SEALING FIBER SEALING COMPOUND

SEALING FIBER SEALING COMPOUND ARCTIC TRACE INSTALLATION INSTRUCTIONS Type GUAT26C Hazardous Location Power Connection and Butt Splice Kit for Temperature Limiting Submersible Heating Cable JUNCTION BOX SEALING FIBER SEAL OFF SEALING

More information

DISCARD DECANTER IF: FAILURE TO COMPLY RISKS INJURY FUNNEL CONTENTS ARE HOT ILLUSTRATED PARTS CATALOG

DISCARD DECANTER IF: FAILURE TO COMPLY RISKS INJURY FUNNEL CONTENTS ARE HOT ILLUSTRATED PARTS CATALOG ! GMB-PS WARNING Disconnect from power source before removal of any panel or replacement of any component! FUNNEL CONTENTS ARE HOT CAUTION DISCARD DECANTER IF:. CRACKED. SCRATCHED. BOILED DRY. HEATED WHEN

More information

SPACESAVER INSTRUCTION MANUAL WARRANTY CERTIFICATE

SPACESAVER INSTRUCTION MANUAL WARRANTY CERTIFICATE SPACESAVER BY INSTRUCTION MANUAL WARRANTY CERTIFICATE Manual design and all elements of manual design are protected by U.S. Federal and/or State Law, including Patent, Trademark and/or Copyright laws.

More information

Electric Mini Tank Water Heaters ME10 ME25 ME40 ME60

Electric Mini Tank Water Heaters ME10 ME25 ME40 ME60 Electric Mini Tank Water Heaters ME10 ME25 ME40 ME60 Installation and Operating Instruction Manual V01.2018 Table of Contents Important Safety Instructions 3 General Information 3/6 Technical Data 4-5

More information

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS FOSTORIA INDUSTRIES, INC. A DIVISION OF FES - Series Portable Electric Heaters YES - Series Suspended Electric Heaters (FES-1524-3E shown) IMPORTANT SAFETY INFORMATION INSIDE Serious injury or death possible.

More information

BUNN A10 & A10-A BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217)

BUNN A10 & A10-A BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217) BUNN A0 & A0-A ILLUSTRATED PARTS CATALOG Designs, materials, weights, specifications, and dimensions for equipment or replacement parts are subject to change without notice. BUNN-O-MATIC CORPORATION POST

More information

MN908 No. 282C Replaces 282B LB7013

MN908 No. 282C Replaces 282B LB7013 No. 282C Replaces 282B LB7013 Instruction Manual For Baldor Dust Control Units Models DC7, DC7 3, DC8, DC8 3, DC10, DC10 3, DC12, DC12 3 and DC14 3. For use on Grinders mounted to GA16 and GA20 pedestals

More information

MaxLite LED MICRO-T PANEL

MaxLite LED MICRO-T PANEL ` Installation Instructions General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all

More information

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number: Seaward Products WATER HEATERS OWNER S MANUAL Serial Number: IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, basic safety precautions to reduce the risk of fire, electrical shock,

More information

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive Installation & Operator s Instruction Manual July 1998 MV1383B Chore-Time TURBO TM Fan Extended Warranty Chore-Time Equipment warrants new TURBO

More information

Roanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario

Roanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario 160 854 Roanoke 48 in Ceiling Fan Owner s Manual Roanoke Ventilador de Techo de 1,22 m Manual del Propietario 48 Roanoke Ceiling Fan by Hampton Bay Thank you for purchasing our ceiling fan. This product

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl50uq, BFL60UQ, BFL70, BFL85 Item Stock Number(s): BFL50UQ, BFL60UQ, BFL70, BFL85 IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY

More information

DISCARD DECANTER IF: FUNNEL CONTENTS ARE HOT FAILURE TO COMPLY RISKS INJURY

DISCARD DECANTER IF: FUNNEL CONTENTS ARE HOT FAILURE TO COMPLY RISKS INJURY ! BUNN GMB-PS WARNING Disconnect from power source before removal of any panel or replacement of any component! FUNNEL CONTENTS ARE HOT CAUTION DISCARD DECANTER IF:. CRACKED. SCRATCHED. BOILED DRY. HEATED

More information

CL & CLG Clamp Mount Mixers

CL & CLG Clamp Mount Mixers CL & CLG Clamp Mount Mixers CL / CLG Series OWNERS MANUAL Warranty Our products are guaranteed against defective materials and workmanship, we will repair or replace such items as may prove defective at

More information

Hawkins 44 in Ceiling Fan Owner s Manual. Hawkins Ventilador de Techo de 1,12 m Manual del Propietario

Hawkins 44 in Ceiling Fan Owner s Manual. Hawkins Ventilador de Techo de 1,12 m Manual del Propietario 117 391 Hawkins 44 in Ceiling Fan Owner s Manual Hawkins Ventilador de Techo de 1,12 m Manual del Propietario 44 Hawkins Ceiling Fan by Hampton Bay Thank you for purchasing our ceiling fan. This product

More information

INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION & OPERATING INSTRUCTIONS INSTALLATION & OPERATING INSTRUCTIONS MODEL #85747 WARMING DRAWER MANUAL TABLE OF CONTENTS PAGE # SAFETY INSTRUCTIONS.........2 INSTALLATION INSTRUCTIONS......................3 ISLAND INSTALLATION...3

More information

VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016

VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016 VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016 HOODMART 172 REASER COURT ELYRIA, OH 44035 PHONE: (800)-715-1014 FAX: (800)-716-1214 1 THIS PAGE LEFT BLANK INTERNTIONALLY 2 LIMITED

More information

Hot Dog Roller Grills

Hot Dog Roller Grills Part No. 87630 Hot Dog Roller Grills Model No. 8022, 8022PE, 8023, 8023SL, 8023PE, 8024, 8024PE, 8024SL, 8025, 8025SL Cincinnati, OH 45241-4807 USA SAFETY PRECAUTIONS DANGER Machine must be properly grounded

More information

The Da-Lite Difference.

The Da-Lite Difference. The Da-Lite Difference. Instruction Book for senior Electrol DA-LITE SCREEN COMPANY, INC. 100 North Detroit Street Post Office Box 17 Warsaw, Indiana 46581-017 Phone: 574-267-8101 800-622-77 Fax: 574-267-7804

More information

Installation and Operation Manual. ACF-18 Automatic Chlorinating Feeder

Installation and Operation Manual. ACF-18 Automatic Chlorinating Feeder Installation and Operation Manual ACF-18 Automatic Chlorinating Feeder Operating Specifications Inlet Flow: 1.0-1.5 gpm Outlet Flow: = Inlet Flow Inlet Pressure: 10-45 psi Maximum Output: 26 lbs. of Available

More information

JOB EXTRACTOR OPERATIONS MANUAL REV A

JOB EXTRACTOR OPERATIONS MANUAL REV A JOB EXTRACTOR OPERATIONS MANUAL REV A October 2002 OPERATOR SAFETY INSTRUCTIONS WARNING DANGER: Failure to read and observe all DANGER statements could result in severe bodily injury or death. Read and

More information

HYDROMATIC. JB-1 System Sewage Ejector Pump Package. Pump Installation and Service Manual

HYDROMATIC. JB-1 System Sewage Ejector Pump Package. Pump Installation and Service Manual Pump Installation and Service Manual HYDROMATIC JB-1 System Sewage Ejector Pump Package NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the

More information

Model 53 Macerator Pump Installation, Operation, Repair Manual

Model 53 Macerator Pump Installation, Operation, Repair Manual Model 53 Macerator Pump Installation, Operation, Repair Manual THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLATION AND OPERATION WARNING: Raritan Engineering

More information

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System 1 Revised 11/18/10 2320 Lakecrest Drive, Pekin IL 61554 PH. (888) 747-4389 Fax (309) 495-0625 Website: www.getzequipment.com LIMITED

More information

LIMITED LIFETIME WARRANTY

LIMITED LIFETIME WARRANTY LIMITED LIFETIME WARRANTY Model No.: F0023 / F0024 aireryder ORIGINAL CEILING FAN LIMITED LIFETIME WARRANTY The limited lifetime warranty covers this ceiling fan, for residential use by the original purchaser,

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl100rnl, BFL125RNL Item Stock Number(s): BFL100RNL, BFL125RNL IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING

More information

Please Read And Save These Instructions.

Please Read And Save These Instructions. RadonAway Ward Hill, MA XP/GP/XR Series Fan Installation Instructions Please Read And Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL SERVICE

More information

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive) 36 & 48 E-Z Cone Fan Installation & Operator s Instruction Manual (Direct Drive) September 1997 MV1433C Chore-Time Warranty Chore-Time Equipment warrants each new product manufactured by it to be free

More information

FLOOR MACHINE EDGER MINI SCRUBBER MODEL E-1

FLOOR MACHINE EDGER MINI SCRUBBER MODEL E-1 FLOOR MACHINE EDGER MINI SCRUBBER MODEL E-1 INTRODUCTION OPERATING & MAINTENANCE INSTRUCTIONS This operator s book has important information for the use and safe operation of this machine. Read this book

More information

SPECIFICATIONS FEATURES

SPECIFICATIONS FEATURES FEATURES Excellent for collecting the large chips which will drop into the garbage can before reaching the impeller. The filter bag filters out the remaining sawdust down to 5 microns. With the cyclone

More information

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

IMPORTANT INSTRUCTIONS - OPERATING MANUAL IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: AK80LSL, AK100LSL Exhaust Fan READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.

More information