1 QUINTA RANGE

2 WHAT S INSIDE 03 WELCOME TO REMEHA 03 REMEHA QUINTA RANGE 04 BOILER CONSTRUCTION 07 OPERATING PRINCIPLE 08 TECHNICAL INFORMATION 10 ENGINEERING SPECIFICATION 12 DIMENSIONS AND CONNECTIONS 14 TYPICAL INSTALLATION 25 ELECTRICAL INSTALLATION AND CONTROLS 26 BOILER CONTROLS 29 QUINTA ACE 160 SPECIFICATIONS 31 FLUE OPTIONS 41 PLUME KITS 54 QUINTA FLUECADE SYSTEM 56 FLUECADE KITS 62 FLUECADE COMPONENTS 67 CASCADE OPTIONS 68 INSTALLATION AND CONFIGURATION 75 TECHNICAL SUPPORT 75 DECLARATION OF COMPLIANCE

3 QUINTA RANGE 03 WELCOME TO REMEHA, THE EXPERT CHOICE WE LEAD THE WAY IN INNOVATION, RELIABILITY AND EFFICIENCY FOR ADVANCED COMMERCIAL HEATING SOLUTIONS. We re completely focused on commercial heating solutions and are at the forefront of condensing gas boiler technology we don t manufacture boilers for anyone else. We invest heavily in research and development which enables our specialist teams to design high performance products at every level. From using the latest materials and manufacturing All our boilers share the same simple design so they re expandable, adaptable and future-proofed. blueprint sign-off through to supply and installation, our customer service and product support is our number one priority. REMEHA QUINTA RANGE The Quinta Range is a market-leading series of versatile, wall-hung condensing boilers designed for space heating and indirect hot water production. The Quinta Range includes the Quinta Pro, which is available in 30, 45, 55, 65, 90, 115 models and the Quinta Ace 160. With their extremely compact design, the Quinta Range can be installed individually or as part of a multi-boiler cascade or rig The Quinta Range is suitable for use on sealed systems and open-vented installations. x 2 FEATURES AND BENEFITS Higher than average energy savings Easy to install in smaller spaces; highly suitable for cascade operation Low pollutant emissions that meet environmental regulations including Building Research Establishment Environmental Assessment Method (BREEAM) regulation and Clean Air Act Clean, trouble-free operation Improved ease of maintenance easy installation Effective space saving solution Improved comfort energy-saving heating

4 QUINTA PRO BOILER CONSTRUCTION KEY 1 Flue gas outlet/air intake Combined Venturi and gas valve unit 12 Fan 3 8 Air intake silencer 13 4 Outlet for measuring combustion gases 9 14 Interior light 5 Ignition/ionisation electrode 10 Siphon 15 Non-return valve

5 BOILER CONSTRUCTION 05 QUINTA ACE BOILER CONSTRUCTION KEY 1 Flue gas outlet/air intake 9 17 Gas pressure measuring point 2 10 Water pressure sensor 18 CU-GH control unit 3 Interior light 11 Return sensor 19 Gas valve unit 4 Flow sensor Venturi 5 Adapter 13 Control panel 21 Fan 6 14 On/off switch 22 Non-return valve 7 15 Condensate collector 23 Automatic air vent 8 Ignition transformer 16 Air inlet silencer 24 Flue gas measuring point

6

7 OPERATING PRINCIPLE 07 QUINTA RANGE OPERATING PRINCIPLE approximately 5 C above the temperature of the system return water, then discharged vertically via the condensate collector, through the 80/125mm (Quinta Pro 30/45) or 100/150mm point (55ºC), this water vapour will begin to condense out in the boiler, transferring its latent heat into the system water, increasing the output of the boiler without increasing gas consumption. Combustion air is drawn into the closed air box by a variable speed fan, through the air inlet connection from the plant room (open- On the inlet side of the fan is a specially designed Venturi which is connected to the outlet side of the gas combi-block. sensor and other external/internal control inputs), the electronic control unit directly monitors the volume of gas and air being delivered to the premix burner. This mixture is initially ignited by the combined ignition/ionisation probe which then monitors the within the pre-set safety time cycle, the controls will shut the

8 QUINTA TECHNICAL INFORMATION % 97.6% 96.03% 97.6% 95.7% 95.4% 95.9% 99.4% 99.1% 97.8% 99.2% 97.9% 97.1% 98.0% 110.4% 110.6% 108.7% 110.4% 108.1% 108% 107.9% 89.5% 89.3% 88.1% 89.4% 88.2% 87.5% 88.3% 99.5% 99.6% 97.9% 99.5% 97.4% 97.3% 97.2% 94% 95% 93% 94% N/a N/a N/a A A A A N/a N/a N/a N/a N/a N/a Natural gas Natural gas Natural gas Natural gas Natural gas Natural gas Natural gas ¾ Male thread (22mm) ¾ Male thread (22mm) ¾ Male thread (22mm) ¾ Male thread (22mm) ¾ Male thread (22mm) ¾ Male thread (22mm) 1 Male thread (28mm)

9 TECHNICAL INFORMATION 09 QUINTA TECHNICAL INFORMATION mm 32mm 32mm 32mm 32mm 32mm 32mm 1¼ Male thread (32mm) 1¼ Male thread (32mm) 1¼ Male thread (32mm) 1¼ Male thread (32mm) 1¼ Male thread (32mm) 1¼ Male thread (32mm) 1¼ Male thread (32mm) o/v 0.3 o/v 0.3 o/v 0.3 o/v 0.3 o/v 0.5 o/v N/a x X4D X4D X4D X4D X4D X4D X1B *Gas consumption based on lower heating value under standard heating conditions: T=288.15K, p= mbar. Gag 30.33, G , G MJ/m 3. **Open vented option maximum operating temperature 75 C.

10 SUGGESTED ENGINEERING SPECIFICATION QUINTA PRO CONSTRUCTION The boiler will be a wall-hung type condensing boiler which may also be installed free-standing on a suitable frame. The single piece, cast aluminium heat exchanger and other major components are contained within a sealed air box. The boiler casing will be complete with a removable front section for maintenance purposes. Electrical and electronic controls will be contained within the instrument panel mounted in the drop-down lower front panel and also the electrical housing mounted on the inside right hand panel. HYDRAULIC, GAS AND FLUE CONNECTIONS condensate connections located at the bottom. The boiler will be be designed for central heating and indirect hot water production up to four bar. The boiler will be suitable for use on sealed systems and open-vented installations. OPERATION The boiler will be complete with a modulating control system that limits the maximum difference in temperature between the pre-mix burner (NG or LPG) with the gas/air ratio control system controlled internally. An intelligent, advanced boiler control will continuously monitor the boiler conditions, varying the heat output to suit the system load. The control will be able to react to and air/gas supply problems), maintaining boiler output for as a negative effect happen in the system, the boiler will reduce its output and/or shut down (shut-off mode), awaiting the negative conditions to return to normal before re-starting. The control frost protection will activate below 7 C with stage one activating CONTROLS The boiler will include a controls package that allows the actual and set values to be read and adjusted on the built-in digital display which also provides normal operating and fault code indication. The controls will come as standard with the following inputs/outputs: DHW temperature input High limit lock out Low water protection Outside sensor (optional) External shunt pump control External system pump control Fault alarm output DHW 3-port valve control or pump Open Therm connection. FEATURES Ultra-low NO x <37mg/kWh Fully modulating Quiet operation <52dB(A) LED illuminated interior Automatic maintenance warning PC connection ErP compliant Relay kit (optional) Premix burner and directives: 90/396EEC Gas appliances directive voltage directive 89/336/EEC E.M.C. directive ErP compliant

11 ENGINEERING SPECIFICATION 11 QUINTA ACE 160 CONSTRUCTION The boiler will be a wall-hung type condensing boiler which may also be installed free-standing on a suitable frame. The single piece, cast aluminium heat exchanger and other major components are contained within a sealed air box. The boiler casing shall be complete with a removable front section for maintenance purposes. Electrical and electronic controls will be contained within the instrument panel mounted in the drop-down lower front panel. This control panel will be HYDRAULIC, GAS AND FLUE CONNECTIONS condensate connections located at the bottom. The boiler will be be designed for central heating and indirect hot water production up to four bar. The boiler will be suitable for use on sealed systems and open-vented installations. OPERATION The boiler will be complete with a modulating control system that limits the maximum difference in temperature between the pre-mix burner with the gas/air ratio control system controlled internally. An intelligent, advanced boiler control will continuously monitor the boiler conditions, varying the heat output to suit the system load. The control will be able to react to external negative problems), maintaining boiler output for as long as possible happen in the system the boiler shall reduce its output and/or shut down (shut-off mode), awaiting the negative conditions to return to normal before re-starting. The control cannot override will activate below 7 C with stage one activating system/shunt CONTROLS The boiler will include a controls package that allows the actual and set values to be read and adjusted on the built-in digital display which also provides normal operating and fault code indication. The controls will come as standard with the following inputs/outputs: DHW temperature input High limit lock out Low water protection Outside sensor (optional) External shunt pump control External system pump control Fault alarm output DHW 3-port valve control or pump Open Therm connection. FEATURES Ultra-low NO x <35mg/kWh Fully modulating Quiet operation <52dB(A) LED illuminated interior Automatic maintenance warning PC connection ErP compliant Relay kit (optional) Premix burner and directives: 90/396EEC Gas appliances directive voltage directive 89/336/EEC E.M.C. directive ErP compliant

12 QUINTA PRO DIMENSIONS AND CONNECTIONS The complete range of Quinta Pro 30, 45, 55, 65, 90 and 115 boilers have a compact design of h750 x w500 x d500mm. KEY 191 Connection of the combustion Ø 80mm ( 45kW) Ø 100mm ( 55kW) Connection of the air intake pipe; Ø 125mm ( 45kW) Ø 150mm ( 55kW) Siphon connection bush Heating circuit return; 1¼ Male thread (32mm) Gas connection; ¾ Male thread (22mm) ¼ Male thread (32mm)

13 DIMENSIONS AND CONNECTIONS 13 QUINTA ACE 160 DIMENSIONS AND CONNECTIONS KEY Flue gas outlet connection; Ø 100mm 143 Air supply connection; Ø 150mm Siphon connection 32mm Flow connection; 1¼ Male thread (32mm) Return connection; 1¼ Male thread (32mm) Gas connection; 1 Male thread (28mm)

14 QUINTA PRO TYPICAL INSTALLATION Time/temp control 230v 6.3 amp supply Condensate Gas Flow Return X Main control PCB PCB - SCU - S02 PCB - SCU - X01 PCB - IF 01 BR BL GN/YW OT BL RL Tout Tdhw Pump hws/3wv Egv Status Status Status PUMP X81 BR BL GN/YW Factory fitted fly lead Time/temp control (volt free) Pump PM1 Alternative 0-10v control Alternative pump PM1 Note: Control PCBs are shown diagrammatically. Earths are omitted for clarity.

15 TYPICAL INSTALLATION 15 QUINTA PRO TYPICAL INSTALLATION Room stat 2 Channel time clock Wiring centre 230v supply Gas Condensate DHW thermostat Flow DHW zone valve c/w end switch Htg zone valve c/w end switch By-pass valve Return Satisfied Cylinder thermostat DHW zone valve End switches close on valve fully open Calling Room thermostat Calling Satisfied HTG zone valve Wiring centre Factory fitted supply lead to be connected to a 230v fused spur for boiler permanent supply Time clock with two live switched outputs DHW on 230v HTG on 230v E N L BR BL GN/YW Live supply to boiler System pump On/off Main control PCB PCB - SCU - S02 PCB - SCU - X01 PCB - IF 01 Shunt OT BL RL Tout Tdhw Pump hws/3wv Egv Status Status Status PUMP X81 230v 6.3 amp switched fuse spur

16 QUINTA PRO TYPICAL INSTALLATION Time/temp control 230v supply Pump SH1 Condensate Pump PM1 Gas Flow Return X BR BL GN/YW Main control PCB PCB - SCU - S02 PCB - SCU - X01 PCB - IF 01 PUMP OT BL RL Tout Tdhw X81 Pump hws/3wv Egv Status Status Status BR BL GN/YW Factory fitted fly lead Time/temp control (volt free) Pump PM1 Alternative 0-10v control Shunt pump SH1 Note: Control PCBs are shown diagrammatically. Earths are omitted for clarity.

17 TYPICAL INSTALLATION 17 loss header. 3-way valve DHW priority Quinta Pro 30/45/55/65 only. QUINTA PRO TYPICAL INSTALLATION Time/temp control 230v supply Pump SH1 DHW thermostat Condensate Pump PM1 A AB B Gas Flow Bypass valve Diverting valve 2 port spring return valve Return X BR BL GN/YW Main control PCB PCB - SCU - S02 PCB - SCU - X01 PCB - IF 01 PUMP OT BL RL Tout Tdhw X81 Pump hws/3wv Egv Status Status Status BR BL GN/YW Factory fitted supply lead to be connected to a 230v fused spur for boiler permanent supply Time/temp control HTG (volt free) Time control DHW (volt free) 2 port spring return valve 230v fused supply for 2 port valve (connected to boiler supply) Wiring detail of controls when using a Remeha Calorifier, a volt free HWS time control and a 2 Port spring return valve. If using a different type of calorifier, please follow manufacturer s instructions regarding control and wiring details 3 way valve Pump PM1 Cylinder thermostat Boiler Tdhw HWS time control 230v fused supply (connected to boiler supply) Live Neutral Boiler signal out (volt free) Boiler signal in (volt free) Thermostat Safety limiter 2 C 1 2 C 1 Orange Grey Blue Brown 2 port spring return motorised valve Shunt pump SH1 Note: Control PCBs are shown diagrammatically. Earths are omitted for clarity.

18 low loss header. Pumped option, DHW priority can be used on all Quinta Pro range (see page 22). QUINTA PRO TYPICAL INSTALLATION Time/temp control 230v supply Pump SH1 DHW thermostat Pump PM2 Condensate Pump PM1 Gas Flow Bypass valve 2 port spring return valve Return X Main control PCB PCB - SCU - S02 PCB - SCU - X01 PCB - IF 01 BR BL GN/YW OT BL RL Tout Tdhw Pump hws/3wv Egv Status Status Status PUMP X81 BR BL GN/YW Factory fitted supply lead to be connected to a 230v fused spur for bolier permanent supply Time/temp control HTG (volt free) Time control DHW (volt free) 2 port spring return valve 230v fused supply for 2 port valve (connected to boiler supply) Cylinder thermostat Pump PM1 Pump PM2 Shunt pump SH1 Wiring detail of controls when using a Remeha Calorifier with a 2 port spring return valve. If using a different type of calorifier, please follow manufacturer s instructions regarding control and wiring details Boiler Tdhw HWS time control Contractor or relay required if both pumps PM1 and SH1 loading exceed 1.5 amps 230v fused supply (connected to boiler supply) Live Neutral Boiler signal out (volt free) Boiler signal in (volt free) Thermostat Safety limiter 2 C 1 2 C 1 Orange Grey Blue Brown 2 port spring return motorised valve Note: Control PCBs are shown diagrammatically. Earths are omitted for clarity.

19 TYPICAL INSTALLATION 19 QUINTA PRO TYPICAL INSTALLATION Normal position for the isense controller mounted in reference room within the building (room compensation) 230v supply 100m Max 1.6M Suggested height in room Pump PM1 Condensate Gas Flow Return X BR BL GN/YW Main control PCB OT BL RL Tout Tdhw PCB - SCU - S02 PCB - SCU - X01 PCB - IF 01 Pump hws/3wv Egv Status Status Status PUMP X81 BR BL GN/YW OT Factory fitted on/off or supply lead to modulating controls be connected to a 230v fused spur for boiler permanent supply Pump PM1 Note: Control PCBs are shown diagrammatically. Earths are omitted for clarity.

20 QUINTA PRO TYPICAL INSTALLATION Normal position for the controller mounted in reference room within the building Outside sensor on North facing wall 100m Max Pump PM1 100m Max 230v supply 1.6M Suggested height in room isense can be fitted in the boiler if used for weather compensation only Condensate Gas Flow Return X BR BL GN/YW Main control PCB PCB - SCU - S02 PCB - SCU - X01 PCB - IF 01 OT BL RL Tout Tdhw Pump hws/3wv Egv Status Status Status PUMP X81 BR BL GN/YW OT on/off or Factory fitted modulating controls supply lead to be connected to a 230v fused spur for boiler permanent supply Outside sensor Pump PM1 Note: Control PCBs are shown diagrammatically. Earths are omitted for clarity.

21 TYPICAL INSTALLATION 21 Heating room or outside weather compensated with Pro 30/45/55/65 only. QUINTA PRO TYPICAL INSTALLATION Normal position for the controller mounted in reference room within the building (room compensation) 100m max 100m max 230v supply 1.6M Suggested height in room Pump PM1 DHW sensor Condensate AB A B DHW diverting valve Gas Flow 2 port spring return valve Bypass valve Return X BR BL GN/YW Main control PCB PCB - SCU - S02 PCB - SCU - X01 PCB - IF 01 OT BL RL Tout Tdhw Pump hws/3wv Egv Status Status Status PUMP X81 BR BL GN/YW OT Factory fitted on/off or modulating controls supply lead to be connected to a 230v fused spur for boiler permanent supply 2 port spring return valve Outside sensor Calorifier sensor 3 way valve Boiler parameter P37 must be set to 0 Pump PM1 230v fused supply for 2 port valve Note: Control PCBs are shown diagrammatically. Earths are omitted for clarity.

22 Heating room or outside weather compensation with used on all Quinta Pro range. QUINTA PRO TYPICAL INSTALLATION Normal position for the controller mounted in reference room within the building (room compensation) 100m max Outside sensor on North facing wall Pump PM1 230v supply 100m max 1.6M Suggested height in room isense can be fitted into boiler control panel for outside weather compensation only Pump PM2 DHW sensor Condensate Gas Flow 2 port spring return valve Bypass valve Return X Main control PCB PCB - SCU - S02 PCB - SCU - X01 PCB - IF 01 BR BL GN/YW OT BL RL Tout Tdhw Pump hws/3wv Egv Status Status Status PUMP X81 BR BL GN/YW OT Factory fitted supply lead to be connected to a 230v fused spur for boiler permanent supply on/off or modulating controls 2 port spring return valve Outside sensor Calorifier sensor Pump PM1 Pump PM2 Boiler parameter P37 must be set to 0 230v 3 amp fuses supply for 2 port valve Note: Control PCBs are shown diagrammatically. Earths are omitted for clarity.

23 TYPICAL INSTALLATION 23 Multiple Quinta Pro boilers, heating only, outside weather or with a low loss header (optimising/weather compensated). QUINTA PRO TYPICAL INSTALLATION Normal position for the controller mounted in reference room within the building 100m max Outside sensor on North facing wall 230v supply Shunt pump Shunt pump Celcia MC4 230v supply 100m max 1.6M Suggested height in room isense can be mounted in boiler for weather compensation only Two to four boilers Condensate Gas Flow Return Pump PM1 Htg flow sensor X BR BL GN/YW Main control PCB PCB - SCU - S02 PCB - SCU - X01 PCB - IF 01 OT BL RL Tout Tdhw Pump hws/3wv Egv Status Status Status PUMP X81 isense mounted in reference room (or boiler for weather compensation only) OT - BUS DIGI Outside sensor on North facing wall 100 max Boiler No. 1 BR BL GN/YW Factory fitted supply lead to be connected to a 230v fused spur for boiler permanent supply Shunt pump On/off Shunt pump On/off Shunt pump On/off OT OT OT System pump PM1 (Max 1amp) Shunt pump Switch spur 230v Rated at 3 amps MC4 X81 X81 X81 L N E E Boiler No.4 Boiler No.3 Boiler No.2 Flow sensor mount on flow pipework to register a comon flow temperature Note: Control PCBs are shown diagrammatically. Earths are omitted for clarity.

24 QUINTA ACE 160 TYPICAL INSTALLATION Hot water cylinder Note: This information is indicative.

25 TYPICAL INSTALLATION AND ELECTRICAL INSTALLATION AND CONTROLS 25 ELECTRICAL INSTALLATION AND CONTROLS QUINTA RANGE GENERAL The Quinta Range is supplied as standard with electronic designed microprocessor at the heart of the control system. SPECIFICATIONS ELECTRICAL SUPPLY The Quinta Range must have a permanent 230V/50Hz single phase supply rated at 6.3 amps. The control unit is not phase/neutral sensitive. CONTROL BOX Electrical rating: 10VA Pump run on (HTG): 1-98 minutes FUSE SPECIFICATION The boiler is protected by fuses: F1 rated at 6.3 amps (slow acting) F2 230V, 2 amps (fast acting) Fan 230V. BOILER TEMPERATURE CONTROL The Quinta Range has electronic temperature control with can be adjusted between 20 and 90 C. HIGH LIMIT TEMPERATURE PROTECTION The high limit, temperature protection device switches off and limit set point (set by boiler type). When the fault is corrected the boiler can be restarted by using the reset key on the control panel. LOW WATER PROTECTION (FLOW AND CONTENT) The Quinta Range is supplied with a low water protection on the basis of a low water pressure switch and also by temperature measurement. By modulating down at the moment that the water long as possible. CONNECTING A THIRD PARTY CONTROL UNIT TO A STANDARD BOARD PCB (PCUS-01) Main PCB control all included as standard. PCB (IF-01) 0-10V control. PCB (SCU-X01) This has two volt free contacts, which can Depending on the setting, a maximum of two messages about the status of the boiler can be transmitted. PCB (SCU-S02) F 4AT X1 SCU-S02 On/off OT BL RL Tout Tdhw 1 2 % IF-01 X5 X4 SCU-X01 Status Status NcCNo NcCNo X2 Status NcCNo OTm NcCNo OTm For control of external central heating pump (pump) and control of external three-way valve (3wV). Other features available. X3 NcCNo NcCNo X3 X2 X2a EXTERNAL CONNECTIONS All external connections are made to any one of the standard supplied PCBs depending on the type of control and external X1 X3 Pump 3wV EgV N L NCD N L Pump N L NCD N L X4 Status NcCNo NcCNo X5 Tsol Gps Tsol Gps Hru Hru

26 BOILER CONTROLS The Quinta Range can be controlled using a number of methods examples of some are given below. Please contact our sales or technical departments for further options. MODULATING (TWO WIRE CONTROL) When using the optional Remeha compensating controllers the heat output modulates between the minimum and maximum applies to both single and multiple boiler installations, under the dictates of a room and/or outside temperature sensor. isense Pro multi-boiler multi zone optimising/compensating controller can control up to ten boilers, two heating zones either VT or CT and one domestic hot water circuit. isense controller single-boiler (option for multiple boiler) single zone optimising/compensating controller. Remeha MC4 provide step control for multi-boiler installation of up to four boilers. Analogue control (0-10V d.c.). The heat output modulates between the minimum and the maximum values on the basis of the voltage supplied by an external analogue (0-10V) input. ON/OFF VOLT FREE CONTROL FROM A THIRD PARTY INSTALLER Connect a two wire cable to terminals on/off OT which must be a volt free connection from the third party controller. ANALOGUE HEAT OUTPUT-BASED CONTROL (%) The 0-10V signal controls the boiler output between 0% and 100% of its total capacity (kw). The minimum and maximum values are limited. The minimum output is linked to the boiler s modulation depth. The output varies between the minimum and maximum value on the basis of the value determined by the controller Boiler off Hysteresis Temp required Boiler off Hysteresis Heat output requested ANALOGUE TEMPERATURE-BASED CONTROL 0 C and 100 C. This control modulates on the basis of the temperature set point calculated by the controller sent by the A jumper 2 (see table opposite) on the interface is used to select either temperature control or heat output control (%).

27 BOILER CONTROLS 27 PRIORITY DHW CONTROL TEMPERATURE CONTROL With a Remeha temperature sensor or with a standard (volt free) DHW thermostat. option is used. With a three-way diverting valve (not Q90/115) With a DHW pump Untimed (available 24 hours a day). SYSTEM/SHUNT PUMP A shunt pump can be connected to the boiler (maximum input the heating return connection and be as close to the boiler as possible. A system pump can also be connected to the boiler FROST PROTECTION system is activated as follows: below 7 C system pump is switched on if connected to the boiler. Below 3 C boiler is pump switch off. Note: This control is designed to protect the boiler for full system protection use a frost thermostat or a weather compensator. REMOTE ALARM AND BOILER RUN INDICATION As standard, the boiler is supplied with two volt free indicators common alarm signal and boiler run signal. Maximum 230 volts, SAFETY INTERLOCKS As standard the boiler is supplied with shutdown (BL) and release (RL) inputs via the main PCB control. SYSTEM WATER specialist water treatment companies in respect to aluminium heat exchangers. For further information Remeha Water Quality Regulations is available from remeha.co.uk The recommendations in the document must be followed.

28

29 QUINTA ACE SPECIFICATIONS 29 QUINTA ACE 160 SPECIFICATIONS The boiler has a three-wire mains lead (lead length 1.5m) and is suitable for a 230VAC/50Hz power supply with a phase/neutral/ earth system. The boiler is not phase sensitive and the boiler is completely pre-wired. ASSEMBLY OF THE CONTROL PANEL The optional PCBs are also placed in the connection box. X07 X06 X08 X05 X09 X10 X04 X03 X11 X021 X2 B C X02 X01 X12 Connectors from the control unit CUGH (Front view) Control panel CU-GH & HMI X X X X04 / X X X X X X X X X012 X013 X022 X021 X041 X051 X053 X054 X055 X081 X071 X083 X121 X X011 7 X20 8 X X07 X06 X04 / X X015 X016 X0141 X V, 50Hz 6 X201 EMC X031 X032 X08 X09 X10 X11 X12 X03 X02 X01 KEY 1 Boiler control unit 8 Control fascia panel 15 Air pressure differential switch 2 Lighting 9 Fan supply 16 Flue gas sensor 3 Ignition probe Ignition transformer 11 Flow sensor 18 Gas valve Gas valve 2 6 N/a 13 Return sensor 7 Service connector/computer connection 14 Hydraulic pressure sensor

30

31 FLUE OPTIONS 31 FLUE OPTIONS available for the room-sealed CLV system. The concentric system can be supplied for individual boilers for horizontal or vertical installation. Because of the excess fan (depending on the boiler model and actual route taken), which enables the installer to position the boiler almost anywhere in the building. with bird guard. Care should be taken when siting the actual discharge point as a vapour plume will be visible when the boiler is operating and it is possible for water to drip to the ground from the terminal on horizontal installations, which could turn to ice in freezing conditions. GUIDELINES maintenance of ventilation for gas appliances not exceeding 70kW (1st, 2nd and 3rd family gases). appliances to chimneys and for maintenance of chimneys not exceeding 70kW (1st, 2nd and 3rd family gases). water boilers of rated inputs between 70kW to 1.8MW (net) (2nd and 3rd family gases). industrial and commercial premises. IMPORTANT NOTE drain/siphon, this must be connected within one metre of the condensate collector. Where boilers have been installed on a seal water type with discharge taken to a suitable drain point. Flue components are constructed from a white painted metal outer and plastic inner. Flue terminals are painted as detailed in the terminal diagrams. Plume kit external components are aluminium or plastic and are painted black.

32 QUINTA RANGE FLUE OUTLET/AIR INLET DETAILS The Quinta Range of boilers are supplied as standard with a system connected to the inner concentric connection with the air supply taken from the boiler house via the outer concentric connection. operation and an option using single skin is available. DETAILS OF INLET CONNECTION Flue gas Air in DETAILS OF CONDENSATE DRAIN To suitable drain point TO SUITABLE DRAIN POINT

33 FLUE OPTIONS 33 QUINTA PRO 30 AND 45 ROOM-SEALED, 80/125MM HORIZONTAL CONCENTRIC FLUE KIT OPTION QP01 installed immediately above another. For two boilers only, it is also possible to install the external terminal wall plates touching each other. Kit parts MG (max wall thickness 500mm) 1 x horizontal terminal Note: Boiler bend and wall plate are included HORIZONTAL FLUE KIT 80/125MM passing through hole in wall to ensure correct positioning 240mm Sq. 4 x 5mm holes 204 Sq Clearance hole for terminal through wall 130mm Note: 140mm diameter the inside wall to allow clearance for the bend Cut terminal on site to suit wall thickness Max 1000mm Min 150mm Kit parts MG (extended version max wall thickness 1000mm) 1 x horizontal terminal Note: Boiler bend and wall plate are included EXTENDED HORIZONTAL FLUE KIT 80/125MM 50mm insertion length into mating socket 50mm insertion length into mating socket 110mm RAL colour 7021/ mm o/d 240mm Sq. 145mm 95mm 150(min)600/1000(max) 80mm o/d 740/1135mm 4 x 5mm holes 204 Sq MG and MG

34

35 FLUE OPTIONS 35 QUINTA PRO 30 AND 45 ROOM-SEALED, 80/125MM VERTICAL CONCENTRIC FLUE KIT OPTION QP03 Kit parts KT1215 (max wall thickness 500mm) 1 x vertical terminal MG x universal roof seal pack VE001 CONCENTRIC VERTICAL FLUE KIT 80/125MM Weathering slate suitable Additional components (within boiler constraints) Condensate drain QP3 0/45/55/65/90/115 = 100mm QP30/45-495mm CONCENTRIC VERTICAL FLUE KIT 80/125MM VERTICAL FLASHING DETAIL 25mm I/D - 32mm O/D 180mm Condensate drain Part No. MG RAL (300mm) 1350mm 80mm approx 600mm x 500mm Cut down to suit diameter of terminal use RAL mm Can be cut down on site to a minimum of 150mm. Retain the difference between inner and outer. Dn80 Dn125 Detail of standard weathering plate for 100mm to 150mm

36 QUINTA PRO 30 AND 45 80/125MM ROOM-SEALED CALCULATED DATA TO DETERMINE MAXIMUM FLUE RUNS Metres Reduction length for each 45 bend Metres 1 1 Reduction length for each 90 bend Metres 2 2 Metres 6 6 Note: Minimum fall back is 2 o or 50mm per metre. Note 2: The components listed below are not for external use. 'L' 125 o/d 'L' Internal seal (80mm) Part No. MG ± o/d Siphon Part No. MG o/d 80 o/d Standard length (cannot be cut) 'L' = 1000mm Part No. MG 'L' = 500mm Part No. MG Standard length (cuttable length) 'L' = 1000mm Part No. MG 'L' = 500mm Part No. MG Internal wall plate Part No. MG Siphon adaptor kit Part No. MG mm I/D - 32mm O/D 125 i/d i/d DN mm 80mm o/d 80 o/d 7 10 M Condensate drain Part No. MG Bend Part No. MG Boiler short bend Part No. MG Bend Part No. MG Extended wall bracket Part No. MG i/d mm ctrs Wall bracket Part No. MG Clamp band Part No. MG (one supplied with each component except MG ) 80/125mm - 100/150mm Concentric adaptor Part No. MG Note 3: All dimensions are in mm.

37 FLUE OPTIONS 37 QUINTA PRO 30 AND 45 ROOM-SEALED, 100MM TWO ZONE CLV FLUE KIT OPTION QP04 Connection in areas of different pressure (C53, C83). Combustion air supply and combustion gas discharge are possible in various pressure zones, semi-clv system, with the exception of coastal areas. The maximum permissible difference in height between the combustion air supply and the combustion gas discharge is 36m. Kit parts KT032 1 x air inlet PU002 1 x condensate drain MG x siphon MG x condense adaptor kit MG CLV FLUE KIT 80/125MM 100mm aluminium single wall Flue outlet T 36m (maximum height) Fall to boiler Fall from boiler Air inlet Condensate drain Quinta Pro 30/45 two pipe adaptor Flue discharge: diameter 100mm length 40m Flue terminal c/w bird guard 100/80mm reducers to adapt boiler to suit Detail of the 100mm two zone CLV Flue Kit Option QP04 (Part No. KT032) Only parts named are in the kit additional 100mm single wall pipe and bends, shown dotted will be needed to suit site Please contact our technical department for advice. Air inlet guard Condensate drain mm reducer x2 Two pipe adaptor plate

38 CONVENTIONAL FLUE QUINTA PRO 30 AND MM CONVENTIONAL OR OPEN-FLUE SYSTEMS Typical single-boiler installation. Ensure that the overall route does not exceed the maximum values in the table on page 40. CONVENTIONAL OR OPEN FLUE SYSTEMS Flue outlet 100mm aluminium single wall flue system Fall to boiler Refer to table on page 39 Air from plant room Condensate drain 100/80mm reducer to adapt boiler to suit 100mm system Detail of standard weathering plate for 100mm to 150mm Cut down to suit dia. of flue 80mm approx 600mm x 500mm

39 FLUE OPTIONS 39 QUINTA PRO 30 AND MM CONVENTIONAL OR OPEN-FLUE SYSTEMS The components listed below are only suitable for internal use as illustrated on pages 37 and 38. As the boiler Metres Reduction length for each 45 bend Metres Reduction length for each 90 bend Metres i/d i/d 15mm ID/32mmO/D 100 o/d 'L' L = 1000mm Part No. MG87062 L = 500mm Part No. MG87061 L = 250mm Part No. MG o/d 10 Reducer 80mm spigot to 100mm Part No. MG87127 connection to adapt to 100mm system Top i/d Part No. PU mm Condensate drain Part No. MG mm Note: 2 x 45 bends will offset to 71mm centres i/d 10 Flue terminal c/w bird guard Part No. PU Bend Part No. MG Bend Part No. MG mm 8mm x 45mm screw thread Part No. MG87183 Twin pipe adaptor plate Mounting bracket Part No. MG87193 Note: All dimensions are in mm.

40 QUINTA PRO 30 AND 45 PLUME KITS 80/125MM FLUE KIT OPTION QP05 point in line with current regulations. Kit parts PMK-horizontal terminal kit KT PMK wall terminal 2. Boiler bend not illustrated 3. Wall plates 4. Plume extension bend (80mm) 7. Flue outlet (80mm) 8. Bird guard 1 x siphon MG (not illustrated) 1 x condensate adaptor kit MG (not illustrated) HORIZONTAL FLUE KIT 80/125MM Max 2000mm Min 150mm Core drill wall 130mm diameter Horizontal terminal plume kit assembly 5 4 with regards to the minimum distances from openings, walls, etc. Flue can be taken directly through rear outside wall or discharged through a side wall left or right. Both must be within the constraints in the table below /125mm Plume Management details. Calculations based on products supplied by Remeha. 3 Metres 6 6 Reduction length for each 45 bend Metres Reduction length for each 90 bend Metres Note: The table shows the maximum lengths allowed. Both the boiler bend 80/25mm concentric) at the spigot and the PMK terminal bend reduction in lengths. The external components for this PMK are constructed of black aluminium. Note 2: The combination of internal concentric and external PMK must not exceed the overall concentric maximum.

41 PLUME KITS 41 80/125MM PLUME MANAGEMENT COMPONENTS PART DETAIL Note: The components listed below must only be used as part of the Plume Management Kit. PMK-horizontal Terminal not supplied as a separate component MG PMK 90 bend (80mm) MG PMK horizontal outlet (80mm) MG MG PMK 45 bend (80mm) MG Bird mesh (80mm) MG PMK wall bracket (80mm) MG Boiler bend (80mm)

42 QUINTA PRO 30 AND 45 MULTI-BOILER INSTALLATION ON A COMBINED HEADER INSTALLATION ON A COMBINED HEADER 80mm boiler connections Tapered cone c/w bird guard For illustration purposes only.

43 PLUME KITS 43 QUINTA PRO 30 AND 45 MULTI OR SINGLE-BOILER INSTALLATION ON A FLUE DILUTION SYSTEM boilers to prevent the dilution fan affecting the gas/air ratio control system in the boiler. INSTALLATION ON A FLUE DILUTION SYSTEM 80mm boiler connections Bellmouth 2 x D + 50mm D Opening in duct 2 x D 30mm Drain Typical duct entry detail

44 QUINTA PRO 55, 65, 90 AND 115 AND QUINTA ACE 160 ROOM-SEALED, 100/150MM HORIZONTAL CONCENTRIC FLUE KIT another. When installing two boilers only, it is also possible to install the external terminal wall plates touching each other. Kit parts MG (max wall thickness 500mm) 1 x horizontal terminal Note: boiler bend and wall plate are included HORIZONTAL FLUE KIT 100/150MM Wall closure plate should be fitted to terminal before passing through hole in wall to ensure correct positioning 240mm Sq. 4 x 5mm holes 204 Sq Clearance hole for terminal through wall 155mm Note: 170mm diameter recess 20mm deep required from the face of the inside wall face to allow clearance for the bend Note: Cut terminal on site to suit wall thickness max 500mm min 150mm Kit parts MG (extended version max wall thickness 1000mm) 1 x horizontal terminal Note: boiler bend and wall plate are included EXTENDED HORIZONTAL FLUE KIT 100/150MM 45mm insertion length into mating socket 115 BS RAL colour 9016 / o/d 240 Sq 140 Note: All dimensions are in mm. 100 o/d 150(min)-500/1000(max) 790/1135 HRS room sealed terminal 100/150 MG & MG x 5mm holes 204 Sq Detail of the 100/150mm horizontal concentric

45 FLUE OPTIONS 45 QUINTA PRO 55, 65, 90 AND 115 AND QUINTA ACE 160 ROOM-SEALED, 100/150MM VERTICAL CONCENTRIC FLUE KIT Kit parts KT x vertical terminal MG x universal roof seal pack VE001 Kit parts KT00310 Contains optional condensate drain VERTICAL FLUE KIT 100/150MM Weathering slate suitable Detail of the vertical 100/150mm Concentric Flue Kit (KT1216) Can be cut on site to a minimum of 150mm minimum of 10mm QP55/65/90/ mm site details (within boiler constraints) Condensate drain QP55/65/90/115 = 100mm Dn100 Dn RAL RAL approx 600 x 500 Cut down to suit diameter of terminal in use

46 QUINTA PRO 55, 65, 90 AND 115 AND QUINTA ACE /150MM ROOM-SEALED CALCULATION DATA TO DETERMINE MAX FLUE RUNS Metres Reduction length for each 45 bend Metres Reduction length for each 90 bend Metres o or 50mm per metre. Note 2: The components listed below are not for external use. 150 o/d 268 ± o/d o/d Cuttable length 1000mm Part No. MG mm Part No. MG Internal wall plate Part No. MG Siphon Part No MG o/d Standard length 1000mm Part No. MG mm Part No. MG mm Offset Silicon seal ring (flue side) Part No. MG Siphon adaptor kit Part No MG i/d i/d DN i/d 90 bend Part No. MG o/d bend Part No. MG o/d 90 boiler short bend Part No. MG (clamp not required) 25mm i/d 32mm o/d 7 10 M Extended wall bracket Part No. MG mm mm ctr s Wall bracket Part No. MG Clamp band Part No. MG (one supplied with each component except MG ) Condensate drain Part No. MG Note 3: All dimensions are in mm.

47 FLUE OPTIONS 47 QUINTA PRO 55, 65, 90, 115 AND QUINTA ACE 160 ROOM-SEALED TWO ZONE CLV FLUE KIT Connection in areas of different pressure (C53, C83). For the Quinta Ace 160, the boiler can be installed on C43 systems Combustion air supply and combustion gas discharge are possible in various pressure zones, semi-clv systems. With the exception of coastal areas, the maximum permissible difference in height between the combustion air supply and the combustion gas discharge is 36m. Kit parts KT030 1 x air inlet PU002 1 x condensate drain MG x siphon MG x condense adaptor kit MG TWO ZONE FLUE KIT 100/150MM 100mm aluminium single wall flue and air inlet system Max length see boiler technical booklet Flue outlet Fall to boiler T 36m (maximum height) Air inlet Fall from boiler Condensate drain Condensate drain Different CLV flue configurations may be available. Please contact our technical department for advice Equivalent length of 45 o elbow (M) Equivalent length of 90 o elbow (M)

48 QUINTA PRO 55, 65, 90, 115 AND QUINTA ACE 160 CONVENTIONAL OR OPEN-FLUE SYSTEMS CONVENTIONAL OR OPEN FLUE SYSTEMS Flue outlet 100mm aluminium single Fall to boiler 50mm / M Air from plant room Condensate drain Reduction length for each 45 bend (M) Reduction length for each 90 bend (M) Please refer to Remeha technical department for further details. *Not supplied by Remeha.

49 FLUE OPTIONS MM SINGLE WALL ALUMINIUM FLUE COMPONENTS ALUMINIUM FLUE COMPONENTS 101 i/d 80 approx Cut down to suit diameter of ue in use and seal with silicone supplied mm x 500mm Detail of standard weathering plate for 100mm to 150mm ue (Part No. VE001) 'L' 101 i/d o/d i/d Flue terminal c/w bird guard Part No. PU001 Standard length L = 1000mm Part No. MG87062 L = 500mm Part No. MG87061 L = 250mm Part No. MG o/d Reducer 80 spigot to 100 socket Part No. MG87127 Must be used on the QP 30/ e connection to adapt to 100mm system Top bend Part No. MG bend Part No. MG87103 Note: 2 x 45 bends will offset to 71mm centres 25-55mm i/d Air inlet guard Part No. PU ± 3 25mm ID/32mmO/D 180mm Mounting bracket Part No. MG mm x 45mm screw thread Silicon seal ring Part No. MG87183 Siphon Part No. MG mm Condensate drain Part No. MG Eccentric flue connector 80/80 Part No. S /100 Part No. S Siphon adaptor kit Part No. MG Note: All dimensions are in mm. Note 2: The only parts that are suitable for external use are VE001, PU001 and PU002.

50 QUINTA PRO 55, 65, 90 AND 115 AND QUINTA ACE 160 PLUME KITS 100/150MM FLUE KIT OPTION QP11 Plume kit termination positions must not be used to circumvent current standards and regulations. The point of exit determines the discharge point, again in line with current regulations. 100/150mm Plume Management Kits QP11 Kit part KT00336 PMK-horizontal terminal kit 1. PMK wall terminal 2. Boiler bend not illustrated 3. Wall plates bend (100mm) 7. Flue outlet (100mm) 8. Bird guard 1 x siphon MG not illustrated 1 x condense adaptor kit MG not illustrated FLUE KIT OPTION Wall depth max 500mm min 150mm Terminal inner and outer can be cut to suit. face of the inside wall surface to allow clearance for the bend. Max 2000mm Min 150mm Core drill wall 155mm Diameter Horizontal terminal kit installed Flue can be taken directly through rear outside wall or discharged through a side wall, left or right. Both must be within the constraints listed in the table below Reduction length for each 45 bend (M) Reduction length for each 90 bend (M) Note: The table shows the maximum lengths allowed. Both the boiler bend 100/150mm concentric) at the spigot and the PMK terminal bend 100mm single Note 2: The combination of internal concentric and external PMK must not exceed the overall concentric maximum.

51 PLUME KITS /150MM PLUME MANAGEMENT COMPONENTS PART DETAIL COMPONENTS PART DETAIL PMK horizontal terminal Not supplied as a separate component MG PMK 45 bend (100mm) MG Bird mesh 100mm MG PMK 90 bend (100mm) Dn 100 MG PMK wall bracket (100mm) MG PMK horizontal outlet (100mm) MG Boiler bend MG PMK 1000mm glue extension piece c/w wall bracket (100mm) Note: The components listed below must only be used as part of the Plume Management Kit.

52 QUINTA PRO 55, 65, 90 AND 115 AND QUINTA ACE 160 MULTI OR SINGLE-BOILER INSTALLATION ON A FLUE DILUTION SYSTEM ratio control system in the boiler. FLUE DILUTION SYSTEM 100mm boiler connections Bellmouth 2 x D + 50mm D Opening in duct 2 x D 30mm Drain Typical duct entry detail

53 PLUME KITS 53 QUINTA PRO 55, 65, 90 AND 115 MULTI-BOILER INSTALLATION ON A COMBINED HEADER MULTI BOILER INSTALLATION 100mm boiler connections Tapered cone c/w bird guard

54 DN 150 FLUECADE SYSTEM The Fluecade system can be used on all of the Quinta Pro boilers from two boilers up to a maximum of six in-line and back-to-back. components. Optional adaptors are available which can be connected to the last boiler connection. Refer to table on page 65. is supplied in 150mm and 200mm only, and is CE approved. Only the components and accessories listed on pages 25 and 32 FLUECADE SYSTEM Kit parts MG Air inlet grill , MG x 2 2. Extension PP 100 L = 500, MG x 2 3. Elbow short PP , MG x 2 4. Collector PP x L = 570, MG x 2 5. Extension PP 150 L = 500, MG x 1 6. Condensate trap PP 150, MG x 1 7. Cover PP 150, MG x 1 9. Wall bracket 150, MG x CTC DN 100

55 DN 150 QUINTA FLUECADE SYSTEM 55 THIS BASIC PP 150MM FLUECADE EXTENSION HEADER KIT IS SUITABLE FOR CONNECTING AN EXTRA QUINTA PRO BOILER IN AN IN-LINE CONFIGURATION IN-LINE CONFIGURATION Kit parts MG Air inlet grill MG x 1 2. Extension PP 100 L = 500 MG x 1 3. Elbow short PP MG x 1 4. Collector PP150 1 x L = 570, MG x 1 5. Wall bracket 150 MG x 1 5 P= DN 100

56 THIS BASIC PP 150MM FLUECADE HEADER KIT IS SUITABLE FOR TWO QUINTA PRO BOILERS IN A BACK-TO-BACK CONFIGURATION Kit parts MG BACK-TO-BACK CONFIGURATION KEY Air inlet grill Wall bracket

57 QUINTA FLUECADE SYSTEM 57 THIS PP 150MM FLUECADE EXTENSION KIT IS SUITABLE FOR TWO EXTRA QUINTA PRO BOILERS IN A BACK-TO-BACK CONFIGURATION Kit parts MG BACK-TO-BACK CONFIGURATION KEY Air inlet grill Wall bracket 150

58 DN 200 THIS BASIC PP 200MM FLUECADE HEADER KIT IS SUITABLE FOR THE CONNECTION OF TWO QUINTA PRO BOILERS IN AN IN-LINE CONFIGURATION for the Quinta Pro range of boilers. Kit parts MG IN-LINE CONFIGURATION CTC DN 150 DN 100 KEY Air inlet grill Wall bracket 150

59 DN 200 FLUECADE KITS 59 THIS BASIC PP 200MM FLUECADE EXTENSION KIT IS SUITABLE FOR THE CONNECTION OF AN EXTRA QUINTA PRO BOILER IN AN IN-LINE CONFIGURATION for the Quinta Pro range of boilers. Kit parts MG IN-LINE CONFIGURATION P= DN 100 DN 150 KEY 1 2 Air inlet grill Wall bracket 200

60 THIS BASIC PP 200MM FLUECADE HEADER KIT IS SUITABLE FOR TWO QUINTA PRO BOILERS IN A BACK-TO-BACK CONFIGURATION for the Quinta Pro range of boilers. Kit parts MG BACK-TO-BACK CONFIGURATION KEY Air inlet grill Wall bracket 200

61 FLUECADE KITS 61 THIS BASIC PP 200MM FLUECADE EXTENSION KIT IS SUITABLE FOR TWO QUINTA PRO BOILERS IN A BACK-TO-BACK CONFIGURATION for the Quinta Pro range of boilers. Kit parts MG BACK-TO-BACK CONFIGURATION KEY Air inlet grill Wall bracket

62 FLUECADE COMPONENTS Flue header 200mm Part No. MG Flue header 150mm Part No. MG Flue header 200mm Part No. MG Flue header 150mm Part No. MG Quinta Pro 30/45 80mm x 125mm boiler connection Part No. MG Air intake grill (parallel) 80mm Part No. MG Air intake grill (parallel) 100mm Part No. MG Air intake grill (concentric) 80/125mm Part No. MG Air intake grill (concentric) 100/150mm Part No. MG mm 90 elbow Part No. MG mm 90 elbow Part No. MG

63 FLUECADE KITS FLUECADE COMPONENTS 63 FLUECADE COMPONENTS Wall bracket 200mm Part No. MG Wall bracket 150mm Part No. MG mm 45 elbow Part No. MG elbow 100mm Part No. MG Part No. MG Condense adaptor Kit parts MG Condensate trap with drain point 150mm Part No. MG Condensate trap with drain point 200mm Part No. MG End cap PP 150mm (no drain point) Part No. MG

64 FLUECADE 200mm PP roof terminal Part No. MG mm PP roof terminal Part No. MG (can t use PP externally) 200mm chimney cap Part No. MG mm chimney cap Part No. MG Ventilation grate 250mm x 300mm (175cm 2 ) Part No. MG Cover plate 300mm x 300mm with sleeve 250mm x 300mm Part No. MG

65 FLUECADE COMPONENTS 65 DATA TO DETERMINE THE MAXIMUM LENGTH AND DIAMETER OF THE FLUECADE SYSTEM FOR THE QUINTA PRO RANGE OF BOILERS Heat input net kw kw CO % 58.6/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / N/a N/a N/a N/a N/a N/a N/a N/a N/a N/a N/a N/a N/a N/a N/a N/a m 1.5m 2m m 3.3m 4.9m Note 1: Length between shaft and last boiler = 1 metre. Note 2: For calculating other horizontal/vertical lengths between the last boiler and the vertical riser the height must be reduced by the number of lengths added to the horizontal over one metre and for any added bends the details in the table adjacent must be used. all joints are air and water tight. Note 4: 150/200mm means; horizontal = 150mm, vertical = 200mm.

66

67 CASCADE OPTIONS 67 CASCADE OPTIONS greater reliability for years. The compact design of the boilers, combined with the smart gas and water connection technology of the cascade system, makes it possible to install a high heat output in a small area. When installing two to eight boilers, our product range includes systems that are very comprehensive and easy to install. The hydraulic and gas system can be put together entirely without welding, using screw connections, compression connections are available for independent cascade installation. Please contact our technical or sales departments for different Quinta Pro 30, 45, 55, 65, 90, 115 boilers are particularly suitable for use in cascade systems due to their small footprint and width of only 50cm which allows an exceptionally compact 115 boilers in line (including low loss header), approximately only C). The cascade systems can be divided into three main groups: wall-mounted mounted on a free-standing frame mounted on a free-standing frame. The boiler side of the cascade systems is sized to 20ºC. The low loss header is based on 20/11ºC. STRUCTURE OF QUINTA PRO AND QUINTA ACE 160 CASCADE SYSTEMS wall or to a free-standing frame. The low loss header supplied A common PVC condensed water discharge pipe (not supplied) can be installed in the frame. For this purpose, holes have been

68 QUINTA PRO INSTALLATION DRAWINGS FOR WALL-MOUNTED CASCADE SYSTEMS The cascade systems can be divided into three main groups: The boiler side of the cascade systems is sized to 20ºC. The low loss header is based on 20/11ºC. QUINTA PRO KEY or 125/DIN 2631 (8 holes) B System return; connection DN 100 or 125/DIN 2631 (8 holes) X Y Low loss header Gas supply connection DN 50 or 65/DIN 2633 (4 holes) Distance to system return concentric connection DIMENSIONS (MM) Width mm

69 INSTALLATION DRAWINGS LINEAR CONFIGURATION 69 QUINTA PRO LINEAR CONFIGURATION, MOUNTED ON A FREE-STANDING FRAME TWO TO EIGHT BOILERS QUINTA PRO A X Y B 270 OV T A KEY or 125/DIN 2631 (8 holes) B System return; connection DN 100 or 125/DIN 2631 (8 holes) X Y Low loss header Distance to system return Gas supply connection DN 50 or 65/DIN 2633 (4 holes) concentric connection DIMENSIONS (MM) Width mm

70 500 QUINTA PRO BACK-TO-BACK MOUNTED OR FREE-STANDING FRAME CONFIGURATION (RG) THREE TO TEN BOILERS QUINTA PRO A B X Y OV KEY B or 125/DIN 2631 (8 holes) System return; connection DN 100 or 125/DIN 2631 (8 holes) X Y Distance to system return Low loss header Gas supply connection DN 50 or 65/DIN 2633 (4 holes) concentric connection DIMENSIONS (MM) Width mm N/a

71 INSTALLATION DRAWINGS LINEAR CONFIGURATION 71 STRUCTURE OF QUINTA ACE 160 CASCADE SYSTEMS Complete cascade options are available for the Quinta Ace 160 with both insulated and non-insulated versions. Two to eight Quinta Ace 160 boilers in a linear QUINTA ACE WALL-MOUNTED DIMENSIONS (MM) Width mm FREE-STANDING DIMENSIONS (MM) Width mm

72 STRUCTURE OF QUINTA ACE 160 CASCADE SYSTEMS Complete cascade options are available for the Quinta Ace 160 with both insulated and non-insulated versions. Three to eight Quinta Ace 160 boilers in a back-to-back QUINTA ACE DIMENSIONS (MM) Width mm N/a

73 80 mm 30 mm INSTALLATION AND CONFIGURATION 73 MULTIPLE OUTPUT QUINTA BOILER CASCADES Please contact your local sales manager for further information. Contact details are available via the website remeha.co.uk QUINTA BOILER CASCADES 80 mm 500 mm 600 mm 600 mm 55 mm 15 mm mm ±5 mm Quinta Pro Quinta Ace Quinta Ace 1924mm ±5 mm Note: Please take into account boiler and component weights.

74 BESPOKE RIG SYSTEMS We provide bespoke rig system service to support consultants in overcoming plant room limitations and tight deadlines. These rigs remeha.co.uk BESPOKE RIG SYSTEMS

WELCOME TO REMEHA, THE EXPERT CHOICE REMEHA QUINTA RANGE FEATURES AND BENEFITS

WELCOME TO REMEHA, THE EXPERT CHOICE REMEHA QUINTA RANGE FEATURES AND BENEFITS QUINTA RANGE WHAT S INSIDE 03 WELCOME TO REMEHA 03 REMEHA QUINTA RANGE 04 BOILER CONSTRUCTION 07 OPERATING PRINCIPLE 08 TECHNICAL INFORMATION 10 ENGINEERING SPECIFICATION 12 DIMENSIONS AND CONNECTIONS

More information

The New Remeha Quinta Pro Selection, Design and Installation of Flue Systems

The New Remeha Quinta Pro Selection, Design and Installation of Flue Systems The New Remeha Quinta Pro Selection, Design and Installation of Flue Systems HIGH EFFICIENCY 110% NCV AT 40/30 C FULLY MODULATING BOILER CONTROL PREMIX BURNER CLEAN COMBUSTION ULTRA LOW NOx BREEAM EXCELLENT

More information

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission The New Remeha Quinta Pro Range Condensing Boilers REMEHA QUINTA PRO RANGE HIGH EFFICIENCY 110% NCV AT 40/30 C FULLY MODULATING BOILER CONTROL PREMIX BURNER CLEAN COMBUSTION ULTRA LOW NOx BREEAM EXCELLENT

More information

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS GAS 110 ECO WHAT S INSIDE 03 WELCOME TO REMEHA 03 INTRODUCING THE REMEHA GAS 110 ECO RANGE 04 BOILER CONSTRUCTION 07 OPERATING PRINCIPLE 08 TECHNICAL INFORMATION 10 ENGINEERING SPECIFICATION 11 DIMENSIONS

More information

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 310/610 ECO PRO RANGE FEATURES AND BENEFITS

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 310/610 ECO PRO RANGE FEATURES AND BENEFITS GAS 310/610 ECO PRO WHAT S INSIDE 03 WELCOME TO REMEHA 03 INTRODUCING THE REMEHA GAS 310/610 ECO PRO RANGE 04 TYPICAL BOILER CONSTRUCTION 07 OPERATING PRINCIPLE 08 TECHNICAL INFORMATION 12 ENGINEERING

More information

GAS 610 ECO PRO. The new Remeha. Condensing Boiler Range REMEHA GAS 310/610 ECO PRO

GAS 610 ECO PRO. The new Remeha. Condensing Boiler Range REMEHA GAS 310/610 ECO PRO The new Remeha GAS 310/610 ECO PRO Condensing Boiler Range REMEHA GAS 310/610 ECO PRO HIGH EFFICIENCY 109.6% NCV FULLY MODULATING BOILER CONTROL PREMIX BURNER CLEAN COMBUSTION ULTRA LOW NOx BREEAM EXCELLENT

More information

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw Superior A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler Outputs 120, 160, 200, 240, 280 kw 1 The Superior is a, pre-assembled floor standing, gas fired high efficiency

More information

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of

More information

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW Stainless steel range of condensing boilers Outputs from 50kW to 660kW Designed to meet carbon reduction targets Lifetime service and support Totally dependable. page 1 www.pottertoncommercial.co.uk Contents

More information

Remeha Quinta 45 and 65

Remeha Quinta 45 and 65 Technical information Remeha Quinta 45 and 65 Remeha Quinta 45/65 High-efficiency condensing boiler for wall mounted installation Output Quinta 45 : Quinta 65 : 9-43 kw 13-65 kw 1 TABLE OF CONTENTS Preface

More information

Remeha Quinta 30. Technical information. High-efficiency. condensing boiler for. wall mounted. installation. Output: kw

Remeha Quinta 30. Technical information. High-efficiency. condensing boiler for. wall mounted. installation. Output: kw Technical information Remeha Quinta 30 R e m e h a Q u i n t a 3 0 High-efficiency condensing boiler for wall mounted installation Output: 5.6-28 kw 1 Remeha Quinta 30 TABLE OF CONTENT Preface 5 1 General

More information

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of

More information

ENERGY TOP. Condensing boiler solutions

ENERGY TOP. Condensing boiler solutions ENERGY TOP Condensing boiler solutions 1 ENERGY TOP > ENERGY TOP RANGE A wide array of flexible solutions both for centralised residential application and big commercial plants The increasing need for

More information

Suggested Schematics with Control and Power Wiring details

Suggested Schematics with Control and Power Wiring details 00 P Suggested Schematics with Control and Power Wiring details Outside Sensor Mount in a sheltered position on orth facing wall ocal temp control Under floor HTG 0v Supply Mains cold water ocal temp control

More information

Remeha Quinta 115. Technical information. Remeha Quinta 115. High-efficiency. condensing boiler for wall. mounted installation.

Remeha Quinta 115. Technical information. Remeha Quinta 115. High-efficiency. condensing boiler for wall. mounted installation. Technical information Remeha Quinta 115 Remeha Quinta 115 High-efficiency condensing boiler for wall mounted installation Output: 18-115 kw 111352.indd 1 2-4-2009 13:19:41 Remeha Quinta 115 TABLE OF CONTENT

More information

CALORA TOWER GAS 15S EX CALORA TOWER GAS 25S EX CALORA TOWER GAS 35S EX

CALORA TOWER GAS 15S EX CALORA TOWER GAS 25S EX CALORA TOWER GAS 35S EX EN Floor-standing high efficiency gas boiler CALORA TOWER GAS 15S EX CALORA TOWER GAS 25S EX Installation and Service Manual C003589-A 300026141-001-07 Declaration of conformity The device complies with

More information

Remeha Quinta 85. Technical information. Remeha Quinta 85. High-efficiency. condensing boiler for wall. mounted installation.

Remeha Quinta 85. Technical information. Remeha Quinta 85. High-efficiency. condensing boiler for wall. mounted installation. Technical information Remeha Quinta 85 Remeha Quinta 85 High-efficiency condensing boiler for wall mounted installation Output: 14-90 kw TABLE OF CONTENT Preface 5 1 General description of the boiler 6

More information

Sirius WH. Working towards a cleaner future

Sirius WH. Working towards a cleaner future Sirius WH Wall Hung Stainless Steel Condensing Boilers Single Boiler Applications: 50 to 110kW Modular Boiler Applications: up to 880kW Working towards a cleaner future heating specialists 1. Product Overview

More information

Sirius FS. Working towards a cleaner future

Sirius FS. Working towards a cleaner future Sirius FS Floor Standing Stainless Steel Condensing Boilers Single Boiler Applications: 50 to 160kW Modular Boiler Applications: up to 640kW Working towards a cleaner future heating specialists 1. Product

More information

The Baxi HE System Boiler Range/Heat Only Range and Baxi GA System/Combi Boiler Range

The Baxi HE System Boiler Range/Heat Only Range and Baxi GA System/Combi Boiler Range The Baxi HE System Boiler Range/Heat Only Range and Baxi GA System/Combi Boiler Range Install warmth, efficiency & peace of mind Contents Solo HE A 1 Megaflo System HE A IE 4 Bermuda BBU HE 7 Flue Options

More information

24V dc Terminals X4. 230Vac Terminals X V dc Electrical connections Volt free Room thermostat on/off

24V dc Terminals X4. 230Vac Terminals X V dc Electrical connections Volt free Room thermostat on/off 5.3.1 24V dc Electrical connections 24V dc Terminals X4 Description Connector X4 Remarks Room stat 6-7 6 = + 24Vdc Frost stat 6-7 Parallel through room stat Power 24Vdc 6 = + 24Vdc, 9 = -. (3VA) Notes

More information

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers 5 YEAR WARRANTY ADVANCE PLUS High efficiency condensing combi and system boilers Android Apple WALL HUNG BOILERS Advance Plus ADVANCE PLUS HIGH EFFICIENCY BOILER RANGE The Advance Plus range is the latest

More information

1 VICTRIX ZEUS Superior kw I features

1 VICTRIX ZEUS Superior kw I features Wall-hung condensing VICTRIX ZEUS Superior kw I is the new range of wall-hung condensing boilers with 54 litre stainless steel storage tank available in two versions with nominal heat output of 26 kw and

More information

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers * 5 YEAR GUARANTEE Inovia High efficiency condensing combi and system boilers WALL HUNG BOILERS Inovia INOVIA HIGH EFFICIENCY BOILER RANGE The Inovia range is the latest in intelligent gas boiler technology

More information

EMC-M 24 EMC-M 24/28 MI EMC-M 30/35 MI EMC-M 34/39 MI

EMC-M 24 EMC-M 24/28 MI EMC-M 30/35 MI EMC-M 34/39 MI Ireland EN Wall-hung gas condensing boilers EMC-M 24 EMC-M 24/28 MI EMC-M 30/35 MI EMC-M 34/39 MI Installation and Service Manual 7602023-02 EG declaration of conformity The device complies with the standard

More information

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 is the new wall-hung condensing boiler for room heating only, set-up for independent functioning and for that in cascade mode

More information

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent CLAS HE WALL-HUNG HIGH EFFICIENCY GAS BOILERS Elegant, efficient and intelligent The high efficiency boiler that saves on energy and costs With specified intelligence, CLAS HE adapts to the householder's

More information

WOLF GAS CONDENSING BOILERS COMFORTLINE

WOLF GAS CONDENSING BOILERS COMFORTLINE WOLF GAS CONDENSING BOILERS COMFORTLINE CGB-35/50 / CGB-75/100 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build

More information

Compact HRE Boiler Range. The smart choice for heating and hot water

Compact HRE Boiler Range. The smart choice for heating and hot water Compact HRE Boiler Range XL The smart choice for heating and hot water The smart choice for heating and hot water Dutch market leader The Netherlands has always been in the forefront of condensing boiler

More information

Power X High Power Condensing Wall-Hung Boilers

Power X High Power Condensing Wall-Hung Boilers Power X High Power Condensing Wall-Hung Boilers NEW Residential Heating/Light Commercial compliant POWER X / High Power Condensing Condensing Wall-Hung Wall-Hung Boilers Boilers Power X: the new high power

More information

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28 The competent brand for energy saving systems NEW Gas-combi boiler CGG-1K-24/28 Gas-combi boiler CGG-1K Technical data room sealed fannned flue model gas combi boiler for low temperature heating and d.h.w.

More information

Compact HE. High efficiency combi boiler. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Compact HE. High efficiency combi boiler. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Compact HE High efficiency combi boiler Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Vokèra is a licensed member of the Benchmark scheme which aims to improve the standards

More information

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C ALKON 50 C ALKON 70 C WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) OUTPUT RANGE from 50 to 560 kw (in battery) WORKING TEMPERATURE no limit on

More information

Wall Hung Condensing Boilers. Working towards a cleaner future. heating specialists

Wall Hung Condensing Boilers. Working towards a cleaner future. heating specialists Paramount two Wall Hung Condensing Boilers Working towards a cleaner future heating specialists Product Overview page 3 Introduction 4 Benefits System & Applications 5 System Requirements 5 Single Boiler

More information

Seradens Super Seradens Super Plus

Seradens Super Seradens Super Plus Premix Full Condensing Combi Boilers Seradens Super Seradens Super Plus 20-28 - 36 kw THE FIRST CONDENSING TECHNOLOGY BOTH IN HEATING AND DOMESTIC HOT WATER IN TURKEY Smaller, more elegant and efficient

More information

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL BRILEY CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER 60 140 kw 0604.2 Beeston Briley cast-iron premix gas-fired boiler 60-140kW Contents 1 Boiler specifications Page 3 2 Appliance general dimensions

More information

Power X High Power Condensing Wall-Hung Boilers

Power X High Power Condensing Wall-Hung Boilers Power X High Power Condensing Wall-Hung Boilers NEW Residential Heating/Light Commercial compliant POWER X / High Power Condensing Condensing Wall-Hung Wall-Hung Boilers Boilers Power X: the new high power

More information

CAST IRON ATMOSPHERIC BOILERS

CAST IRON ATMOSPHERIC BOILERS CST IRON TMOSPHERIC OILERS 006 gas-fired, central heating only, electronic ignition High efficiency boilers designed heating large domestic application. Ideal for installation in any boiler room. Cast-iron

More information

WALL-HUNG HIGH EFFICIENCY GAS BOILERS

WALL-HUNG HIGH EFFICIENCY GAS BOILERS Heating Hot water Renewables GAS BOILERS E-COMBIevo E-SYSTEMevo CLAS HEevo CLAS HEevo system CLAS HE R WALL-HUNG HIGH EFFICIENCY GAS BOILERS Ariston a tradition that evolves For many years, we have entered

More information

COMPACT HRE ECO RF COMPACT HRE & ECO RF SMART CHOICE FOR HEATING AND HOT WATER

COMPACT HRE ECO RF COMPACT HRE & ECO RF SMART CHOICE FOR HEATING AND HOT WATER COMPACT HRE ECO RF COMPACT HRE & ECO RF SMART CHOICE FOR HEATING AND HOT WATER THE SMART CHOICE FOR HEATING AND HOT WATER DUTCH MARKET LEADER Intergas has been at the forefront of boiler manufacture in

More information

Ciao Green Condensing Wall-Hung Boilers

Ciao Green Condensing Wall-Hung Boilers Ciao Green Condensing Wall-Hung Boilers Residential Heating Ciao Green A cost-consciuos condensing boiler CIAO GREEN is one of the condensing boilers with the best price-quality ratio on the matket. Kitchen

More information

INDEPENDENT COMBINATION & SYSTEM BOILERS.

INDEPENDENT COMBINATION & SYSTEM BOILERS. INDEPENDENT COMBINATION & SYSTEM BOILERS. RELIABLE IDEAL BOILERS EXCLUSIVELY AVAILABLE AT YOUR LOCAL INDEPENDENT MERCHANT. *7 YEAR WARRANTY UNTIL 31ST DEC 2016 ON INDEPENDENT+. 1 GREAT BOILERS FROM GREAT

More information

Baxi 600, 400 & 200 boilers. Range guide

Baxi 600, 400 & 200 boilers. Range guide Baxi 600, 400 & 200 boilers Range guide A brand you can trust Baxi has been manufacturing in the UK for over 150 years. It has a heritage of providing cutting edge heating products for homes and is the

More information

VICTRIX Superior kw Export VICTRIX Superior kw X Export

VICTRIX Superior kw Export VICTRIX Superior kw X Export Wall-hung condensing VICTRIX Superior kw is the instantaneous sealed chamber wallhung boiler with power of 32 kw which, thanks to condensation technology, is characterised for its high efficiency and guarantees

More information

C 330 ECO - C 630 ECO

C 330 ECO - C 630 ECO EN Gas fired floor-standing condensing boiler C 330 ECO - C 630 ECO Installation, User and Service Manual 760053-01 EG declaration of conformity The device complies with the standard type described in

More information

The iqe Boiler Range. Combination and System T Boilers.

The iqe Boiler Range. Combination and System T Boilers. The iqe Boiler Range Combination and System T Boilers www.iqe.co.uk iqe - Max Technology Max Efficiency iqe is a select group of partners that have come together to create a unique product range of highly

More information

Remeha Avanta Plus. Remeha Avanta Plus. Installation and service manual. Remeha Avanta Plus 28c. Remeha Avanta Plus 35c. Remeha Avanta Plus 39c

Remeha Avanta Plus. Remeha Avanta Plus. Installation and service manual. Remeha Avanta Plus 28c. Remeha Avanta Plus 35c. Remeha Avanta Plus 39c Installation and service manual Remeha Avanta Plus Remeha Avanta Plus Remeha Avanta Plus 28c Remeha Avanta Plus 35c Remeha Avanta Plus 39c Remeha Avanta Plus 24s 1 Remeha Avanta Plus INTRODUCTION 1 SAFETY

More information

Residential Heating Boilers

Residential Heating Boilers Residential Heating Boilers BAXI BAXI Luna Duo-Tec GA+ QUALITY HYDRONIC HEATING EQUIPMENT The best in European design & manufacturing giving you warmth, efficiency and total peace of mind. Residential

More information

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model Calder Plus High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing Outputs 70-3500 kw Calder Plus Model 70-1300 Calder Plus Model 1400-3500 Calder Plus - High Efficiency

More information

Installation & Service Manual Remeha Avanta Range. 24c 28c 35c 39c 18s 24s 30s

Installation & Service Manual Remeha Avanta Range. 24c 28c 35c 39c 18s 24s 30s Installation & Service Manual Remeha Avanta Range 24c 28c 35c 39c 18s 24s 30s Remeha Avanta Plus Benchmark places responsibilities on both manufacturers and installers. The purpose is to ensure that customers

More information

Compact HRE and ECO RF Boiler Range. The smart choice for heating and hot water

Compact HRE and ECO RF Boiler Range. The smart choice for heating and hot water Compact HRE and ECO RF Boiler Range The smart choice for heating and hot water The smart choice for heating and hot water Dutch market leader Intergas has been at the forefront of boiler manufacture in

More information

Remeha Gas 610 ECO. Technical information. Remeha Gas 610 ECO. High efficiency condensing. boiler with low NO X emission. Heat outputs: kw

Remeha Gas 610 ECO. Technical information. Remeha Gas 610 ECO. High efficiency condensing. boiler with low NO X emission. Heat outputs: kw Technical information Remeha Gas 610 ECO Remeha Gas 610 ECO High efficiency condensing boiler with low NO X emission Heat outputs: 87-1146 kw 1 62568.indd 1 18-6-2009 15:35:21 Remeha Gas 610 ECO CONTENTS

More information

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model Calder Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing Outputs 70-3500 kw Calder Model 70-1300 Calder Model 1400-3500 Calder - Steel Hot Water Boiler The Calder

More information

Ultra Boiler Series 1 & 2 Jacket Parts

Ultra Boiler Series 1 & 2 Jacket Parts GAS Ultra Boiler Series 1 & 2 Jacket Parts 9 10 8 6 7 1 5 2 3 Fig. Part Description Model Mfr. 1 383-500-135 Jacket Front Door 595-000-000 595-000-001 595-000-002 595-000-003 Panel Door Jacket Plastic

More information

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers Ethos Range High Efficiency Domestic Boilers Combination Boilers Condensing Combination Boilers Condensing System Boilers From 1994, Mikrofill has been supplying high quality products to the commercial

More information

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017 24 1 2 23 3 4 5 20 6 I 19 7 18 8 9 15 14 11 13 12 i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book i 24 OFF MAX E STATUS BURNER RESET MIN PRE MIN MAX HEAT PREHEAT

More information

Project Name: Location: Engineer: Contractor: I. GENERAL

Project Name: Location: Engineer: Contractor: I. GENERAL Part I - General Part II - Product Part III - Installation Project Name: Location: Engineer: Contractor: I. GENERAL I. PRODUCT Rep: Date: A. Supply and install modulating and condensing boiler(s) as specified

More information

Our Boiler Family Our Boiler Family

Our Boiler Family Our Boiler Family Our Boiler Family 2017 Our Boiler Family 02 Biasi / About Us About Us... Contents Welcome to the world of Biasi Since its inception in Italy in the 1930s, the Biasi name has become trusted around the world

More information

S-AF Floor Standing Condensing Boiler kW

S-AF Floor Standing Condensing Boiler kW Clean Heating Naturally STREBEL MMERCIAL BOILERS S-AF Floor Standing Condensing 11-620 Why choose Strebel? S-AF Floor Standing Condensing Strebel Ltd has been supplying, installing and servicing coercial

More information

HEAT ONLY & COMBI BOILER

HEAT ONLY & COMBI BOILER Spare Parts Catalog Riva Plus HEAT ONLY & COMBI BOILER M135.30 CM / M135.30 CR Prepared by: QHT, Inc. Portsmouth, NH 603-334-6400 phone www.qhtinc.com Rev: 06.23.09 1 06/09 2 06/09 TABLE OF CONTENTS Description

More information

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data INSPIRED EF F ICIENCY CONDENSING BOILERS ETHOS 350 & 550 FLO O R ST AN D I N G CO N DE N SI N G BOI L E R S T ECHN I CAL DO CUME N TA T I O N I SSUE 0 3 /1 6 R e v. 0 1 TABLE OF CONTENTS 1. 2. 3. 4. 5.

More information

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25) ALKON CARGO ALKON CARGO model Max/min nominal output Heat input condensing Non-condensing η condensation at 30 part load 35 7,4 35,1 6,7 33,5 34,8 106,3 Efficiency class (directive 92/42) ALKON CARGO is

More information

ecotec plus New high efficiency condensing combination and system boiler ranges

ecotec plus New high efficiency condensing combination and system boiler ranges ecotec plus New high efficiency condensing combination and system boiler ranges Simply high performance With condensing boilers becoming ever more widely used the need for high performance products that

More information

Introduction. Our boilers are among the most efficient available, designed to be easy to install, reliable and economical.

Introduction. Our boilers are among the most efficient available, designed to be easy to install, reliable and economical. Range Guide >90% Introduction At Baxi, we know a lot about how people react to heat. We ve been at the heart of people s homes for over a century and a half. But while our products respond to people s

More information

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book USER GUIDE IMAX XTRA EL 320-620kW For Installation Guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance

More information

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS CI/SfB 56.83 X RHeco Series CONDENSING GAS FIRED UNIT HEATERS RHeco Series CONDENSING GAS FIRED UNIT HEATERS Introduction Features & Benefits Model Range Reznor continue their tradition of manufacturing

More information

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER Heat 45 & 55 User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER CE/PI No. 86-CN-69 Heat 45 - GC No. 41-930-40 Heat 55 - GC No. 41-930-41 These instructions

More information

AC WhisperGen System Product Specification 11 June 2003

AC WhisperGen System Product Specification 11 June 2003 AC WhisperGen System Product Specification 11 June 2003 Functional Description The WhisperGen (WG) is a cogeneration appliance for domestic installations, replacing a gas fired central heating boiler,

More information

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw 90 kw Clyde Alkon 90 LP Gas Floor standing condensing boilers Natural Gas 90 kw Contents General information Dimensions and Data Installation requirements Boiler wiring diagram Hydraulic systems Page Fully

More information

INSTALLATION AND SERVICING

INSTALLATION AND SERVICING INSTALLATION AND SERVICING IMAX XTRA E80 E120 E160 E200 E240 E280 For Users Guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to

More information

Single Wall Flue system. Installation manual WARNING. Installation Manual CoxDENS PPs MC-CG-105 EN_892054

Single Wall Flue system. Installation manual WARNING. Installation Manual CoxDENS PPs MC-CG-105 EN_892054 MC-CG-105 EN_892054 WARNING Installation Manual CoxDENS PPs Incorrect installation of Flue System and Components, or failure to follow installation instructions, can result in property damage or serious

More information

Strebel SC-B Wall-Hung Condensing Boiler

Strebel SC-B Wall-Hung Condensing Boiler Strebel SC-B Wall-Hung Condensing Boiler INSTALLATION OPERATING & MAINTENANCE INSTRUCTIONS Version 3.1-Jul/06 Strebel is not liable for any damage caused by incorrectly following these instructions. 1.

More information

Q - Series Boiler. Troubleshooting Manual

Q - Series Boiler. Troubleshooting Manual Q - Series Boiler Troubleshooting Manual WARNING There are a number of live tests that are required when fault finding this product. Extreme care should be used at all times to avoid contact with energized

More information

Ultramax PB. Floor standing premix gas fired condensing boilers with outputs at 65, 85, 100 & 120kW BOILERS

Ultramax PB. Floor standing premix gas fired condensing boilers with outputs at 65, 85, 100 & 120kW BOILERS Ultramax PB Floor standing premix gas fired condensing boilers with outputs at 65, 5, 100 & 120kW BOILERS Feature packed and powerful Ultramax PB range of floor standing boilers includes four models with

More information

Installation and Servicing Instructions R29 & R40 HE conventional Wall mounted condensing boiler for central heating

Installation and Servicing Instructions R29 & R40 HE conventional Wall mounted condensing boiler for central heating Installation and Servicing Instructions R29 & R40 HE conventional Wall mounted condensing boiler for central heating 6 720 610 577-01.10 ZB 7-28 R29 HE GC-Number: 47 311 60 ZB 11-40 R40 HE GC-Number: 47

More information

WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILERS. Efficient, economical and easy

WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILERS. Efficient, economical and easy E-COMBI WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILERS Efficient, economical and easy Reliable, advanced Easy to install Easy installation, commissioning and servicing The E-COMBI range has been designed

More information

Compact. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Compact. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Compact Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Contents Design principles and operating sequence Page 1.1 Principle components 2 1.2 Central heating mode 2 1.3

More information

PRODUCT CATALOGUE Issue 3 SYSTEM BOILERS COMBI BOILERS FLOOR STANDING BOILERS WATER HEATERS SPARE PARTS AFTER SALES SERVICE TRAINING

PRODUCT CATALOGUE Issue 3 SYSTEM BOILERS COMBI BOILERS FLOOR STANDING BOILERS WATER HEATERS SPARE PARTS AFTER SALES SERVICE TRAINING PRODUCT CATALOGUE 2006 Issue 3 SYSTEM BOILERS COMBI BOILERS FLOOR STANDING BOILERS WATER HEATERS SPARE PARTS AFTER SALES SERVICE TRAINING THE BRAND OF CHOICE The brand of choice the boiler for you Quality

More information

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank 1 FEATURES Wall-mounted with storage tank Compact wall-mounted open chamber boiler with conventional flue and 45 litre stainless steel storage tank and nominal heat output of 23.7 kw (20,382 kcal/h). AVIO

More information

SEDBUK & HARP. the complete range of oil and gas fired condensing boilers. Warmflow Boilers HIGH EFFICIENCY

SEDBUK & HARP. the complete range of oil and gas fired condensing boilers. Warmflow Boilers HIGH EFFICIENCY the complete range of oil and gas fired condensing boilers Warmflow Boilers warmflow - the perfect choice Warmflow has been established as a privately owned company since 1970. During this time we have

More information

The Ideal Logic. Combination, Heat Only and System Boilers. Heating Solutions.

The Ideal Logic. Combination, Heat Only and System Boilers. Heating Solutions. The Ideal Logic Combination, Heat Only and System Boilers Order No. Description 123170 Logic Combi 24kW 123171 Logic Combi 30kW 123172 Logic Combi 35kW 107560 Logic Combi 24kW (incl. flue) 107561 Logic

More information

Wall hung combination

Wall hung combination Wall hung combination ONDENSING boiler NORTH AMERIA Murelle EV HE 30 Follow Us! Search Sime North America @SimeBoilers Our videos on You Tube (SimeBoilers) Search Sime North America www.simenorthamerica.com

More information

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual.

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual. 1 MHG Heating Ltd ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual. Unit 4 Epsom Downs Metro Centre, Waterfield, Tadworth, Surrey, KT20 5LR Telephone 08456 448802 Fax 08456 448803

More information

Hamworthy. Varmax. New. Fully modulating, low NOx, stainless steel, condensing boilers Natural Gas or LPG Outputs 120kW to 900kW

Hamworthy. Varmax. New. Fully modulating, low NOx, stainless steel, condensing boilers Natural Gas or LPG Outputs 120kW to 900kW New Twin return connections Wide differential temperature up to Seasonal efficiency (gross) Hamworthy Varmax Fully modulating, low NOx, stainless steel, condensing boilers Natural Gas or LPG Outputs 120kW

More information

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data INSPIRED EF F ICIENCY CONDENSING BOILERS ETHOS 70, 90, 1 10 & 130 W ALL MO UN T ED CO N D EN SI N G BO I L E R S T ECHN I CAL DO CUME N TA T I O N I SSUE 1 0 /1 7 Re v. 0 3 TABLE OF CONTENTS 1. 2. 3.

More information

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater Part I - General Part II - Product Part III - Installation Project Name: Location: Engineer: Contractor: I. GENERAL Rep: A. Supply and install modulating and condensing boiler(s) as specified herein. Date:

More information

95% Hamworthy Fully Modulating, Low NOx, Stainless Steel, Condensing Modular Boilers. Wessex ModuMax mk3. New. Restyled with latest Siemens controls

95% Hamworthy Fully Modulating, Low NOx, Stainless Steel, Condensing Modular Boilers. Wessex ModuMax mk3. New. Restyled with latest Siemens controls New Restyled with latest Siemens controls 40 C ΔT ErP & Part L 2013 Compliant up to 95% Seasonal efficiency (gross) Hamworthy Fully Modulating, Low NOx, Stainless Steel, Condensing Modular s Available

More information

Logic+ Combi

Logic+ Combi USER GUIDE Logic+ Combi 24 30 35 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use

More information

turbomax plus High performance combination boiler range

turbomax plus High performance combination boiler range turbomax plus High performance combination boiler range The winning combination High performance, simple installation and servicing are combined in the turbomax plus combination boiler range. Vaillant

More information

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book USERS GUIDE Esprit eco 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification

More information

NEW BUILD YOUR COMPLETE SOLUTION.

NEW BUILD YOUR COMPLETE SOLUTION. NEW BUILD YOUR COMPLETE SOLUTION. IDEAL BOILER STELRAD RADIATOR CYLINDER SOLAR PANEL DESIGN STAGE SAP DESIGN SERVICE 364 DAYS A YEAR WWW.IDEALBOILERS.COM 02 WELCOME TO FIRST CLASS. WITH A RANGE OF WARRANTIES

More information

High temperature air-to-water heat pumps

High temperature air-to-water heat pumps Designed to replace conventional boilers and produce domestic hot water 4 High temperature hot water (+65 C) 4 Winter operation (-20 C) 4 High energy efficiency (CP) 4 Compact and quiet 4 Scroll compressors

More information

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant ... RHeco... ErP 2021 ErP Lot 21 Seasonal Efficiency and NOx compliant RHeco...... Reznor continue their tradition of manufacturing high efficiency warm air heating equipment with the introduction of the

More information

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant ... RHeco... ErP 2021 ErP Lot 21 Seasonal Efficiency and NOx compliant RHeco...... Reznor continue their tradition of manufacturing high efficiency warm air heating equipment with the introduction of the

More information

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND Aqua Balance AquaBalance TM CONTROL MODULE QUICK START GUIDE 10 1 Domestic Hot Water temperature setpoint decreasing button 2 Domestic Hot Water temperature setpoint increasing button 3 Central Heating

More information

Light commercial products. High output boilers Cascade systems

Light commercial products. High output boilers Cascade systems Light commercial products High output boilers Cascade systems District heating FlowSmart Make Alpha your first choice Over the course of nearly 50 years, we have successfully met the heating requirements

More information

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw GAS FIRED ATMOSPHERIC ELECTRONIC VERSION 51-102 kw GENERAL DESCRIPTION 900 D a3 1000 762 672 E 222 The PEGASUS F2 range of atmospheric natural gas-fired boilers are constructed of cast iron finned sections

More information

Alpha CD13R,18R and 24R

Alpha CD13R,18R and 24R Installation and Servicing Instructions Alpha CD3R,8R and 24R Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Regular Boiler Range For Technical help or for Service call...

More information

and Installation Instructions The installation instructions for the Unit pressure jet oil burner is included in the pressure jet oil burner pack.

and Installation Instructions The installation instructions for the Unit pressure jet oil burner is included in the pressure jet oil burner pack. Technical Guide and Installation Instructions MKS / MUS Steel boiler 70-550 kw The installation instructions for the Unit pressure jet oil burner is included in the pressure jet oil burner pack. The control

More information

SPECIFICATIONS - NIKE

SPECIFICATIONS - NIKE Wall-mounted instant boilers NIKE Mini kw Special is the ideal Immergas solution for modern building and wherever space is limited and has to be made the most of. Simple to use and easy to install, thanks

More information