1 HydroMassage Electrical / Installation Preparation Requirements Electrical Requirements Series 340 / 350 Models (*Important- the items below are required for EACH HydroMassage unit). Requires a single-phase, dedicated line supplying a voltage within the range of 208-volt to 240-volt power. o 30-amp dedicated breaker o 30 Amp, 250 volt NEMA L6-30R Locking Receptacle (three prong plug). o Requires 10 gauge wire (2 hot legs and a ground*) Requires a 110 Volt outlet within 5 of the center of the HydroMassage bed. CAT-5 or CAT-6 terminated network jack (able to connect to front desk PC). NEMA L6-30R Locking Receptacle G X Y Water Requirements Distilled water contains no chlorine and is free of minerals and other chemicals that can cause build-up and decrease the life expectancy of key components. Distilled water is available at most major supermarkets or directly from your water supplier (if you have a water delivery service). Series 340 / 350 Models 25 Gallons of Distilled Water Room Preparation Guidelines For best results, it is recommended that an A/C thermostat is installed inside the room (or return air vent if practical). For recommended room sizes, please see HydroMassage Zone layout section. If access to the room is difficult (narrow hallways, small doors, tight turns etc.) please sketch a diagram showing key dimensions of doorways, hallways and corners, and forward to your sales representative or order processor. Carpeting underneath the machine will dramatically reduce the noise while the machine is in operation. We also recommend installing the machine at least 15 feet away from the reception or waiting area. Specifications 94 (239cm) long, 40 (95cm) wide, 27 (69cm) high, Weight: 260lbs (118kg) without water 460lbs (209kg) with 25 gallons (95L) of distilled water. Page 4 of 11
2 HydroMassage ~ Electrical Wiring Illustrations (Drawings not to scale). View #1: Top-down view of room layout 9 X = Preferred location for 220V electrical outlet (E in diagram below) is at the foot end of the bed, approx 10 from the adjoining wall View #2: Side-view of wall (not to scale) 10 Foot end of bed *A- Two-gang plastic electrical box installed at light-switch height, 48 above floor for T-Max Timer (ONLY if T-Max Timer used). **14 from head-end wall for T-Max start/delay bypass. For wired T-Max, daisy chain wire from tanning beds through this box. Terminate with two RJ-22s. Repeat for each bed. 14 *B- ½ or larger conduit connecting T-max to electrical outlets (ONLY if T-Max used) 48 A 9 *C- Single gang electrical box with plastic cover, 6 above floor or minimum height allowable by code (ONLY if T-Max Timer used). 6 C D 94 HydroMassage Dimensions 94 L x 41 W Distance between right-side wall and E = Approx 10 Distance between F & E = Approx 44 Distance between C & D = 1 ½ Distance between left-side wall and A or C = Approx 14 F 54 E 10 E- 220V Receptacle. 208V-240V, 30A, L6-30 locking receptacle. 10-gauge, 2 hots and a ground. 10 away from wall. D- 110V Outlet. Single-gang 2-outlet 15 A, 110V. 1 ½ away from C. If necessary, location of outlets above may be moved within +/- 5. Call for details. *Items A, B, and C ONLY to be installed if T-Max Timer will be used. F- CAT-5 or CAT-6 terminated network jack (able to connect to front desk PC). This is separate from the T-Max box. Unique set of items A, B, C, D, E, F required FOR EACH HydroMassage bed installed (i.e. must install another set if a second or third bed is to be installed in the same room). Page 5 of 11
3 HydroMassage ~ Electrical Outlet Locations Electrical Outlets for clubs using T-Max *A- Two-gang plastic electrical box installed at light-switch height, 48 above floor for T-Max Timer *C- Single gang electrical box with plastic cover D- 110V Outlet. Singlegang 2- outlet 15 A, 110V. F- CAT-5 or CAT-6 terminated network jack box. E- 220V Receptacle. 208V-240V, 30A, L6-30 locking receptacle. 10- gauge, 2 hots and a ground Electrical Outlets for clubs using HydroMassage Software F- CAT-5 or CAT-6 terminate d network jack box. D- 110V Outlet. Singlegang 2- outlet 15 A, 110V. E- 220V Receptacle. 208V-240V, 30A, L6-30 locking receptacle. 10- gauge, 2 hots and a ground Page 6 of 11
4 HydroMassage ~ Regulating Usage in the Club Overview The HydroMassage beds are set-up to be regulated by the front desk staff. When idle, a message box is displayed on the Touchscreen instructing members to see the front desk to gain access to use HydroMassage. OPTION #1: HydroMassage Remote Manager Software (Preferred) The HydroMassage proprietary Remote Manager Software is the simplest and cleanest option to control HydroMassage beds. Only requires a CAT5 cable connecting to the bed (no timer mounted on the wall). No risk of the wall timer breaking or being damaged. Runs from the computer at the front desk. A small window pops-up on the desktop allowing staff to control usage of all beds. Does not conflict with Visionary. Provides access to HydroMassage tech support for upgrades and troubleshooting. Cost: Software ($119-1X per club), CAT-5 cable (approx $179 for 1000 roll) OPTION #2: T-Max Manager with 3A Wall Timer Historically, T-Max systems were used by fitness clubs with several tanning beds This is the preferred option for clubs that do not have a computer at the front desk. T- Max Manager sits at the front desk, and a 3A timer is mounted on the wall next to the HydroMassage bed. Wall timer plate is thin and has a history of damage by members, causing additional expense which involves contacting T-Max Corporate for tech support. Requires hole cut in wall for wall timer. Cost (per bed): T-Max Timer ($135), Wireless Access Point ($77.25). For wired T-Max systems, daisy chain wire from tanning beds through two-gang electrical box. Terminate with two RJ-11s. Repeat for each bed. Page 7 of 11
5 HydroMassage ~ HVAC Requirements (Drawing not to scale) The following is an HVAC scenario which will eliminate the need for the (additional) external cooling system to be installed in the HydroMassage room. **If for any reason these requirements can t be met, please call to discuss an alternate solution (see page 9 for additional details). MINIMUM HVAC REQUIREMENTS: A. 300 CFM HVAC supply and return per HydroMassage unit (i.e. 900 CFM for room with 3 beds). Additional CFM may be necessary if room is normally warm (ex. clubs in the south, room on west side of building, etc). OPTIMAL HVAC SET-UP (In addition to 300 CFM supply and return per bed): B. One CFM exhaust fan installed above the room, with two separate vents to remove heat. C. No doors at entrance or exit of room to allow for open airflow through the room. D. Thermostat installed in room if possible (this is the best case scenario). 18 A. 1-2 air returns A. Two air supplies 10 B. Optional- Exhaust fan above room with two separate vents privacy wall Foot-end Head-end This is the external cooling system that must also be supplied if the above requirements can t be met. See page 8 for additional details. Page 8 of 11
6 HydroMassage External Cooling System **This external cooling system is NOT REQUIRED if the HVAC Requirements on previous page are able to be met. Overview / Need for Cooling System: When HydroMassage beds are installed in a private room without a large supply of cold air, an additional external cooling system is required in order for the beds to be operated all day long without any risk of overheating. System Specifications: Dimensions: 21 L x 19 W x 14-1/2 H Weight: 75 lbs Electrical Supplied from HydroMassage Unit Room Design Considerations: Airflow Direction The cooling system is connected to the massage bed via one electrical cord and two small ¼ tubes (the tubes enter the unit from the side and need 5 of clearance). This allows for installation of the cooling system in several different locations up to 20 away from the massage bed including above the room (ceiling), below the room (basement), or in an adjacent room or space. If the cooling system will be installed directly above the room (suspended in the same manner as an air handler), two ¾ conduits should also be installed for both the tubing and electrical cord; terminating at single gang boxes near the foot end of the bed. Make sure to include pull strings in the conduits. For liability purposes, HydroMassage technicians are not permitted to install the cooling system above the room. Please contact your general contractor to ensure this is completed properly. *IMPORTANT: The external cooling system will vibrate very slightly while in use. For this reason, if the cooling system is installed on a platform above the room, it is necessary to secure it to the platform to prevent it from moving and potentially falling (ex. adding a lip around the perimeter of the platform, using straps to secure the cooling system, etc). Cooling system above massage room. Power cord and water lines connect to bed. Please call the HydroMassage Technical Support department at x 1013 with any questions concerning the external cooling system. Page 9 of 11
Soltron Sea Shell XXS-35
Soltron Sea Shell XXS-35 Forever Tan 113 Freeland Lane Charlotte, NC 28217 1-800-447-0040 For questions concerning this guide please contact Jeremy Welch: jeremyw@forevertan.net (704)971-4744 Electrical
More informationErgoline Affinity 500
Ergoline Affinity 500 Forever Tan 113 Freeland Lane Charlotte, NC 28217 1-800-447-0040 For questions concerning this guide please contact Jeremy Welch: jeremyw@forevertan.net 704-971-4744 local Electrical
More informationHydroMassage Initial Start-up
Hydro Initial Start-up 1) Make sure Hydro power cord is NOT plugged into 220V outlet. If the Touchscreen is not turned on, the bed should never be plugged in at the 220V electrical outlet. 2) Underneath
More informationErgoline Open Sun 1050
Ergoline Open Sun 1050 Forever Tan 113 Freeland Lane Charlotte, NC 28217 1-800-447-0040 For questions concerning this guide please contact Jeremy Welch: jeremyw@forevertan.net (704)971-4744 Electrical
More informationSoltron XS-45 Flirt. Forever Tan 113 Freeland Lane Charlotte, NC
Soltron XS-45 Flirt Forever Tan 113 Freeland Lane Charlotte, NC 28217 1-800-447-0040 For questions concerning this guide please contact Jeremy Welch: jeremyw@forevertan.net (704)971-4744 Electrical 7 pages
More informationModel 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual
Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual FILTER COVER VENTILATION CONTROLLER INLET COLLAR OUTLET COLLAR SAFETY INSTRUCTIONS WARNING 1. 120 Volts may cause serious injury
More informationADVANCING HVLS technology through controls and energy efficiency
WAVE HVLS FANS Kelley High Volume Low Speed fans are designed to provide an energy-efficient solution for large spaces. HVLS fans require much less energy than traditional HVAC systems, and provide year-round
More informationAir Handler Installation Instructions Water Lines
Air Handler Installation Instructions Units must be installed with at least 1 clearance from combustible surfaces. It is recommended that the unit be set on blocks, pads, or legs. Unit should not be sitting
More informationHealthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.
PRODUCT SPECIFICATIONS INDOOR AIR QUALITY HCWHD Healthy Climate Whole-Home Dehumidifier Bulletin No. 210699 November 2017 Supersedes April 2017 MODEL NUMBER IDENTIFICATION Nominal Capacity - 70 to 130
More informationWIRING DIAGRAM. This manual describes the unit features and explains how to set-up, operate and maintain these AirPac Models. COOLIT2600 COOLIT2900
WIRING DIAGRAM This manual describes the unit features and explains how to set-up, operate and maintain these AirPac Models. COOLIT2600 COOLIT2900 17 THANK YOU! WARRANTY INFORMATION Thank you for choosing
More informationINDOOR AIR QUALITY CCWH Complete Comfort Whole-Home Dehumidifier ENGINEERING DATA. Nominal Capacity - 65 to 135 pints per day CCWH - 090
ENGINEERING DATA INDOOR AIR QUALITY CCWH Complete Comfort Whole-Home Dehumidifier Bulletin No. CCWH (08/2011) CCWH-065 CCWH-090 CCWH-135 ENERGY STAR Rating for CCWH-065 Model Only Nominal Capacity - 65
More information28 1/2"* 72.4 cm. (*28 1/2 " to include hinges.) 41 3/4" 106 cm. 27" 68.6 cm. 28 1/2"* 72.4 cm. (includes hinges.) 28 1/2"* 41 3/4" 106 cm
Commercial Single Load Dryers 28 1/2"* 72.4 cm PRODUCT DIMENSIONS (*28 1/2 " to include hinges.) 28 1/2"* 72.4 cm (*28 1/2 " to include hinges.) Models MDE/MDG21PD MDE/MDG21PS MDE/MDG21PR MDE/MDG21PN 43
More informationModel 8140 and 8140NC Fresh Air Ventilator Installation and Operating Instructions
Model 8140 and 8140NC Fresh Air Ventilator Installation and Operating Instructions MODEL 8140 FRESH AIR ILATOR MODEL 8140NC FRESH AIR ILATOR FILTER COVER ILATION CONTROLLER FILTER COVER ILATION TERMINALS
More informationOperation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.
Spot Cooling Systems, Inc. 120 Century Drive Suite 00 Carrollton, TX 7006 00-6-776 Operation Manual SCT1B and SCT1B Warning! Improper installation, adjustment, alteration, service, or maintenance can cause
More informationPackaged Terminal Air Conditioner (PTAC)
Air Conditioner / Electric Heater 16" 42" Depth More Easy-To-Use Features Effortless Temperature Control Frigidaire air conditioners maintain the preset room temperature so the room remains comfortable
More informationGallery Electric Fireplaces
Gallery Electric Fireplaces Homeowner s Installation Instructions & Operating Manual Model: GBI-34, GBI-41 Only use this heater as described in this manual. Any other use is not recommended by the manufacturer,
More informationP-200T / P-200AT / P-230AT (115V / 60Hz)
P-200T / P-200AT / P-230AT (115V / 60Hz) XPOWER Mini Air Movers are certified professional level multifunctional utility blower fans with the most efficient engineering design Features: Low power draw
More informationInstallation Instructions Wall Ovens
Installation Instructions Wall Ovens TESTED IN ACCORDANCE WITH THE LATEST EDITION OF UL858 STANDARD FOR HOUSEHOLD ELECTRIC COOKING APPLIANCES. IMPORTANT 1. Before beginning installation, please thoroughly
More informationModel 8142 and 8142NC Fresh Air Ventilator Installation and Operating Instructions
Model 8142 and 8142NC Fresh Air Ventilator Installation and Operating Instructions MODEL 8142 FRESH AIR ILATOR MODEL 8142NC FRESH AIR ILATOR OUTLET COLLAR MOUNTING BRACKET ILATION CONTROLLER OUTLET COLLAR
More informationModels. Options. Standard Features. LoH 2 O
LoH O Models LoH O Standard Features Uses 8 gallons (9. liters) of water per hour with sanitizing hot water rinse All tanks and hoods constructed from durable stainless steel with a No. finish and heliarced
More informationPackaged Terminal Air Conditioner (PTAC)
FRP12ETT2R Air Conditioner / Electric Heater Product Dimensions Height 16" Width 42" Depth 13-13/16" More Easy-To-Use Features Comfort Control Design Simple controls allow guests to customize their settings,
More informationPackaged Terminal Air Conditioner (PTAC)
Air Conditioner / Heat Pump / Backup Electric Heater 16" 42" Depth More Easy-To-Use Features Comfort Control Design Simple controls allow guests to customize their settings, while quiet, uniform air movement
More informationOWNER S MANUAL MULTIPURPOSE UTILITY AIR MOVER PLEASE READ AND SAVE THESE INSTRUCTIONS X-400WFK (WITH FILTER KIT) ITEM NO:
MULTIPURPOSE UTILITY AIR MOVER OWNER S MANUAL X-400WFK (WITH FILTER KIT) ITEM NO: 621-1531 TOLL FREE NO: 1-855-855-8868 PLEASE READ AND SAVE THESE INSTRUCTIONS Index Introduction...... 2 Operation / Instructions...
More informationPROFESSIONAL AIR MOVER OWNER S MANUAL
X-600/ X-600A/ X-630 P-600/ P-630 (115V/230V) PROFESSIONAL AIR MOVER OWNER S MANUAL X-600 / X-600A / X-630 P-600 / P-630 XPOWER MANUFACTURE, INC. 220 Clary Avenue San Gabriel, CA 91776, USA Tel: 626-285-3301,
More informationJFT Flight Machine. JFT Flight Machine. Models. Options. Standard Features. JFT Flight Machine
JFT Flight Machine Models JFT Flight Machine Options Project Item Quantity CSI Section 00 Approval Date Blower dryer Additional wash section Additional load module Additional unload module (8m) wash down
More informationL CONNECTION NETWORK Commercial Controls
L CONNECTION NETWORK Commercial Controls SIMPLIFIED, CENTRAL CONTROL Simplified Control for Your Facility The L Connection Network not only enhances comfort and energy-efficiency throughout your facilities,
More informationPackaged Terminal Air Conditioner (PTAC)
Packaged Terminal Air Conditioner (PTAC) Air Conditioner / Heat Pump / Backup Electric Heater 16" 42" Depth 21-3/4" More Easy-To-Use Features Comfort Control Design Simple controls allow guests to customize
More informationOPERATING & SERVICE PARTS MANUAL HDS-215 COMBINATION SHRINK SYSTEM
OPERATING & SERVICE PARTS MANUAL HDS-215 COMBINATION SHRINK SYSTEM FOR HOT KNIFE AND IMPULSE MACHINES READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING EQUIPMENT TABLE OF CONTENTS Electrical Requirements
More informationDESIGN CLASS FUNCTION
PROFESSIONAL QUALITY COOKING EQUIPMENT INSTALLATION MANUAL FOR PERFORMER SLIDE-IN COOK TOPS MODEL NUMBERS: AROBSCT-424, AROBSCT-242GD, AROBSCT-24X2GR, AROBSCT-430, AROBSCT-636, AROBSCT-436GD, AROBSCT-436GR,
More informationIMPORTANT SAFETY INFORMATION:
Owner s Manual Model G70 IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to install or use this heater. For your safety, always comply with all warnings and safety instructions
More informationDAVE LENNOX SIGNATURE COLLECTION PureAir S Air Purification System
PRO SPECIFICATIONS INDOOR AIR QUALITY PCO3S DAVE LENNOX SIGNATURE COLLECTION PureAir S Air Purification System Bulletin No. 210857 April 2018 * icomfort S30 Ultra Smart Thermostat * Not furnished - Order
More informationInstallation Guide. 15 W./24 W. Undercounter Refrigeration U L. Viking Range Corporation. 111 Front Street. Greenwood, Mississippi USA
Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-845-4641 U L C U L 15 W./24 W. Undercounter Refrigeration
More informationCase Study: SUPERMARKET APPLICATION
Case Study: SUPERMARKET APPLICATION Supermarket Sees Overall Energy Savings and Solutions to Problems of Sweating Doors, Hot/Cold Areas, Severe Energy Loss, and Customer Safety The following is a complete
More informationSMART+ PRODUCTS Infrared Heater. Safety Notice
OWNERS INSTALLATION AND OPERATING MANUAL SMART+ PRODUCTS Infrared Heater Model: SPP-500-1WP Safety Notice Please read this entire Installation and Operating Manual BEFORE installing and using your new
More informationELECTRONIC AIR CLEANER SAFETY AND INSTALLATION MANUAL MODEL 5000 TABLE OF CONTENTS
ELECTRONIC AIR CLEANER SAFETY AND INSTALLATION MANUAL MODEL 5000 TABLE OF CONTENTS Safety Instructions...2 Specifications...2 Components...3 Installation...4 Operating Instructions...6 Trouble Shooting
More informationHeat Recovery Ventilator Model PVe Light Industrial Commercial Institutional
Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional 1,000-6,000 cfm 2.0 in. wg External Static Pressure Aluminum Plate Heat Exchanger April 2017 Heat Recovery Ventilators Greenheck
More informationDescription of the vacuum
Description of the vacuum by RSBH-O, RSBH-C, RSBH-SB RSBHP-O & RSBHP-C Owner s Manual Contents IMPORTANT SAFETY INSTRUCTIONS... 3 Safety Features... 4 Polarization Instructions... 4 Benefits... 5 Description
More informationZoneline vertical packaged terminal air conditioners
GE Zoneline vertical packaged terminal air conditioners Home products and services Appearance All the benefits of PTAC with the aesthetics and versatility of central air. Zoneline vertical units give any
More informationB.C.S. Shop Heaters 26, 30 & 36 (36 shown)
BIOMASS COMBUSTION SYSTEMS, INC. 67 MILLBROOK ST., SUITE 502 WORCESTER, MA 01606 508-798-5970 - FAX 508-798-5971 B.C.S. Shop Heaters 26, 30 & 36 (36 shown) INSTALLATION MANUAL HAND FIRED SYSTEMS 8-09 Biomass
More informationInstallation Guide. 15 W./24 W. Undercounter Refrigeration
Installation Guide 15 W./24 W. Undercounter Refrigeration Table of Contents Warnings & Important Information 3 Proper Disposal 4 Dimensions (15 W. Professional) 5 Dimensions (24 W. Professional) 6 Dimensions
More informationEco-Safe Digester. Installation Manual For E3 Series Digesters. Version 1.6 Published: Apr. 13, 2017
Eco-Safe Digester Installation Manual For E3 Series Digesters Version 1.6 Published: Apr. 13, 2017 Eco-Safe Digester Installation Manual Table of Contents Preface... iv 1. Document Revision History...
More informationEBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News, VA 23606 Tel: 757 873 6800 Fax: 757 873 3632 Website: www.ebacusa.com UNPACKING
More informationGPF Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL
DESCRIPTION Controls all Lutron 3-Wire Fluorescent Dimming Ballasts (Hi-Lume, ECO-0, and Compact SE). Provide power and dimming for up to 4 fluorescent circuits. Models available for: 0V: 8 to 4 circuits.
More informationOperator Manual Countertop Pizza Oven
Operator Manual Countertop Pizza Oven PO18, PO18-220, PO22 Model PO-18 Table of Contents Safety Information...2 Specifications...3 Unpacking...4 Installation...4 Operation...4 Cleaning and Maintenance...5
More informationINSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER
INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER IMPORTANT MASSAGE TO INSTALLER: "The United States Environmental Protection Agency ("EPA") has issued various regulations regarding the
More informationS AGE E NGINEERING A SSOCIATES, LLP
S AGE E NGINEERING A SSOCIATES, LLP 1211 Western Avenue Albany, NY (518) 453 6091 F (518) 453 6092 Kingston Library Mechanical and Electrical Systems Field Report Date of Visits: Mechanical - September
More informationPTAC/PTHP. Packaged Terminal Air Conditioners and Heat Pumps. Residential & Light Commercial HVAC. Features: Performance:
Residential & Light Commercial HVAC PTAC/PTHP Packaged Terminal Air Conditioners and Heat Pumps Fedders Packaged Terminal Air Conditioners are designed to fit all 16" H x 42" W wall sleeves. They are the
More informationUnit HH Gregg. ± 30,000 SF Width ±26' Lakeland Retail Center. Lease Outline Drawing. Unit HH Gregg. Depth ± 145' HVAC Units & Information
Lease Outline Drawing Lakeland Retail Center 4000 US Hwy. 98, Unit HH Gregg, Lakeland, FL 33809 ±26' ±200' Lease Line Unit HH Gregg ±46' Lease Line ±21' Unit HH Gregg ±145' Lease Line ± 30,000 SF Width
More informationAn Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010
An Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010 Putnam County Planning & Development Services Building & Zoning Division Compliance Section PO Box 1486 Palatka, FL 32178 1486 Office
More informationSMART+ PRODUCTS INFRARED HEATER. Safety Notice
OWNERS INSTALLATION AND OPERATING MANUAL SMART+ PRODUCTS INFRARED HEATER Model: SPP-1000X-6WB Safety Notice Please read this entire Installation and Operating Manual BEFORE installing and using your new
More informationModel 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions
Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions ON/OFF button used to turn the ventilator on and off Up/Down buttons used to change humidity or vent time setting
More information5120_School_Intercom_Rack_Spec.doc 10/10/07
****************************************************************************************** 16720-3 Simplex TrueCom 5120 Inter Communication System Advanced 360 Station, Rack Mounted, Intercom / Paging
More informationGeneral Kitchen, Bath & Bedroom Remodeling Notes County of Marin, Building Inspection Division
These Notes are intended to assist in issuing simple remodel permits. It provides information on the most common requirements relating to the construction or remodeling of kitchens, bathrooms and bedrooms.
More informationModel 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions
Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions ON/OFF button used to turn the ventilator on and off Up/Down buttons used to change humidity or vent time setting
More informationSECTION NURSE CALL SYSTEM
NURSE CALL SMARTCARE NURSE CALL SOLUTION Architectural Specifications Part 1 General SECTION 275223 - NURSE CALL SYSTEM 1.0 Summary 1.1 This section includes nurse call system and requirements for system
More informationRead these instructions carefully and completely. NOTE This appliance must be properly grounded.
Built-In Wall Oven Installation Instructions 24 (61 cm) model SEW24SS If you are in need of service, please either fill out a service request on our website, http://www.summitappliance.com/support, or
More information_5120_School_Intercom_Rack_Spec.doc 09/21/04
****************************************************************************************** 16720-3 Simplex TrueCom 5120 Inter Communication System Advanced 360 Station, Rack Mounted, Intercom / Paging
More informationHVAC Equipment Access Equipment Location
City of Lancaster- Building Department 121 East Chestnut Street, Suite 102, Lancaster, Ohio 43130-3825 (740) 687-6649, Fax (740) 681-5030 Web site: www.ci.lancaster.oh.us/dept/building HVAC Heating, Ventilating,
More informationOPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1000T DUAL FUEL CONSTRUCTION HEATER
OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For F-1000T DUAL FUEL CONSTRUCTION HEATER CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7 2000/ CSA 2.14 2000 Gas Fired
More informationAH-470. Flat Panel Micathermic Space Heater OWNERS MANUAL. Read and save these instructions.
Flat Panel Micathermic Space Heater AH-470 OWNERS MANUAL Read and save these instructions. A Name You Can Trust Trust has to be earned and we will earn yours. Customer happiness is the focus of our business.
More informationOPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER
OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For F-400T DUAL FUEL CONSTRUCTION HEATER CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7 2000/ CSA 2.14 2000 Gas Fired
More informationGE LightSweep Lighting Control System Guideform Specification
GE Lighting Control GE LightSweep Lighting Control System Guideform Specification If you have any questions at all regarding this specification, please contact your local GE Lighting Control representative,
More informationINSTRUCTIONS! DO NOT DISCARD!
INSTRUCTIONS! DO NOT DISCARD! CAUTION! Do NOT install where injury might occur due to Moving parts, Sharp corners, Hot surfaces or electrical components d N0417 Page 1 of 10 INSTALLATION INSTRUCTIONS CAUTION
More informationModel 1750A/ 1770A Dehumidifier Installation Instructions
Model 1750A/ 1770A Dehumidifier Installation Instructions Safety Instructions WARNING 1. Improper installation may cause property damage or injury. Installation, service, and maintenance must be performed
More informationteambrite Supply Mytee Escape ETM-LX-115 Electric Truckmount, 115V with 165 ft hose set and carpet cleaning wand Includes the following items:
S Created on: : Thursday 01 November, 2018 Model Number: 20171201 Mytee Escape ETM-LX-115 Electric Truckmount Start Package 165 ft hose set Wand 20171201 Manufacturer: Mytee Products Inc Mytee Escape ETM-LX-115
More informationClick Here To View Item at
Click Here To View Item at www.gappower.com TRADESMAN FORCED AIR LP/NG HEATERS Engineered to deliver reliable, directional heat, L.B. White Tradesman heaters feature a unique 3-trial ignition system,
More informationInstructions for Baptistry Immersion System
Instructions for Baptistry Immersion System Models: BIS-60-240 (240v.) BIS-15-120 (120v.) Upgraded - Safety lifting handle Upgraded - High limit protection Upgraded - Visual Diagnostic Sytem lights VDS
More informationTRUE INDUCTION DOUBLE BURNER MINI DUO COOKTOP MANUAL
TRUE INDUCTION DOUBLE BURNER MINI DUO COOKTOP MANUAL DOUBLE BURNER MINI DUO INDUCTION COOKTOP MANUAL 1 TABLE OF CONTENTS I. II. III. IV. V. VI. VII. VIII. Control Panel Overview Cooktop Installation Important
More informationUnit # E ± 1,200 SF Width ± 20' Depth ± 60'
Lease Outline Drawing ±60' Lease Line Sunnymead Plaza 24907 Sunnymead Blvd., Unit # E, Moreno Valley, CA 92553 Unit # E ± 1,200 SF Width ± 20' Depth ± 60' Plans produced by: ID Plans 6/13/2017 (813) 657-2545
More informationThe Eco-Safe Digester. Installation Overview
The Eco-Safe Digester Installation Overview Digester Site Selection ALL WORK AND COSTS ASSOCIATED WITH THE SITE PREP PHASE ARE THE CUSTOMER S RESPONSIBILITY. With guidance from the customer, we help select
More informationDetection System Model 3500 Series
Detection System Model 3500 Series Architect/Contractor Information Package 3M Library Systems 3M Center, Building 225-4N-14 St. Paul, Minnesota 55144-1000 Copyright 2001-2006 3M. All rights reserved.
More informationCOMMERCIAL WASHERS MODELS T-300/350/400/450/600/650/750/900/950/1200/1450 VENDED C-SERIES CONTROL
COMMERCIAL WASHERS MODELS T-300/350/400/450/600/650/750/900/950/1200/1450 VENDED C-SERIES CONTROL OPERATOR S MANUAL INSTALLATION & OPERATION INSTRUCTIONS Please read this information and retain for reference.
More informationElectrical Design Guidelines Table of Contents
C: Compliant Rev. 3 Dated June 13 11 NC: Non-Compliant NA: Not Applicable Page1 16.1 General 16.2 Single Line Diagrams 16.3 Electric Motor Equipment and Controls 16.4 Lighting 16.5 Emergency Lighting 16.6
More informationEBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products, Inc. 700 Thimble Shoals Blvd, Suite 109 Newport News, VA. 23606-2575 Tel: (757) 873 6800 Fax: (757) 873 3632 Website www.ebacusa.com
More informationField Start-Up Sheet Direct Fired Gas Equipment
Customer: Sales Representative: Model Number: Serial Number: Field Start-Up Sheet Direct Fired Gas Equipment ***Please Print*** INITIAL INSPECTION I. Installer Responsibilities 1. Remote Panel: All interconnecting
More informationProduct Specifications. Vertical Floor Consoles By First Co.
NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series
More informationInstallation Instructions
Installation Instructions For NoFrost Combined Refrigerator-Freezers CS 1400 PC CS 1400 R CS 1410 7085 589-00 Important Please Read and Follow these Instructions These instructions contain Danger, Warning
More informationOCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters
1200 North Main Street Fostoria, OH 44830 Phone: 800-495-4525 Fax: 419-435-0842 A DIVISION OF www.fostoriaindustries.com OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters *EXCLUDING
More informationVentZone Systems VentZone Zoned IAQ with Heat Recovery Kits
RESIDENTIAL SYSTEM SOLUTIONS VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits VentZone Zoned IAQ Kits with Heat Recovery combine a Standard Residential Heat Recovery Ventilator (HRV) with residential
More informationBag-In-A-Box Oil System Instruction Manual Model #2257EX & 2257DX For Export Bag-In-Box Pumps Made After March 2003
Part No. 79431EX Revised: February 2009 Bag-In-A-Box Oil System Instruction Manual Model #2257EX & 2257DX For Export Bag-In-Box Pumps Made After March 2003 Shown Here with Optional 2457S Heated Line Kit.
More informationSafety and Installation Instructions Model 1700
Dehumidifier Filter Access Humidity Control Inlet Filter Access Outlet Service Access Port Wiring Access Wire Routing Port Drain On/Off Switch Safety and Installation Instructions Model 1700 INSTALLER
More informationOCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters
TPI Corporation P.O. Box 4973 Johnson City, TN 37601 www.tpicorp.com OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters *EXCLUDING RESIDENCES IMPORTANT SAFETY INFORMATION INSIDE possible
More informationLOW PROFILE AIR MOVER
PLEASE READ AND SAVE THESE INSTRUCTIONS LOW PROFILE AIR MOVER OWNER'S MANUAL MODEL: PL-700A, XL-700A, XL-730A, XL-760AM (115V/60HZ) XPOWER MANUFACTURE, INC. 240 Clary Avenue San Gabriel, CA 91776, USA
More informationEBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 700 Thimble Shoals Boulevard Newport News VA 23606-2575 Telephone (757) 873-6800 Fax (757) 873-3632 Website: www.ebacusa.com INTRODUCTION
More informationINSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER
ASPEN MANUFACTURING 373 ATASCOCITA RD. HUMBLE, TX 77396 TEL (281) 441-6500 FAX (281) 441-6510 > INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER IMPORTANT: "The
More informationDimplex Electric Thermal Storage (ETS) Product Guide - Nova Scotia
Dimplex Electric Thermal Storage (ETS) Product Guide - Nova Scotia Dimplex Electric Thermal Storage (ETS) Heating Product Guide Model: VFMQ LI-926 2012/03 Key Homeowner Benefits 1. Lower Space & Water
More informationRooftop Unit, Heat Pump and Indoor Air Quality Application Guide VT8600 Series Room Controllers
Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide VT8600 Series Room Controllers TABLE OF CONTENTS Overview 2 VT86X0U5X00B 2 heating / 2 Cooling for Rooftop unit and Indoor air quality 3
More informationCFS-2000 CHILLER TM. Operating Instructions P/N (110 VAC) P/N (230 VAC)
CFS-2000 CHILLER TM Operating Instructions P/N 100100 (110 VAC) P/N 100105 (230 VAC) Thank you for purchasing this CFS-2000 CHILLER TM! As you will notice from the table of contents, the manual for your
More informationFOUNTAINS UGA DESIGN & CONSTRUCTION SUPPLEMENTAL GENERAL REQUIREMENTS & STANDARDS APRIL 30,
13 12 00 FOUNTAINS A. Due to water conservation efforts and the high maintenance requirements of fountains, new interior and / or exterior fountains are not allowed. B. If a variance is granted for a fountain,
More informationOwner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532
Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationFully Automatic Water Softeners
OWNERS GUIDE TO INSTALLATION AND OPERATION Fully Automatic Water Softeners SINGLE TANK CABINET MODELS TWO TANK MODELS Read the instructions carefully and learn the specific details regarding installation
More informationTradesman Tradesman K Norseman Workman Sun Blast Premier Foreman Torches. New
Tradesman Tradesman K Norseman Workman Sun Blast Premier Foreman Torches New TRADESMAN FORCED AIR LP/NG HEATERS Engineered to deliver reliable, directional heat, L.B. White Tradesman heaters feature a
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS INSTALLATION REQUIREMENTS Tools and Parts Gather required tools and parts before starting installation. Tools needed: Optional tools: Flashlight Options: Bucket Pedestal: You
More informationULTRA-SAUNA HEATER. Proudly made in USA since Gas Heaters - 40,000-80,000 BTU. Installation Instructions & User Manual
Heater Model Serial # Installation Guide ULTRA-SAUNA HEATER Proudly made in USA since 1964 Gas Heaters - 40,000-80,000 BTU Installation Instructions & User Manual PO Box 636 Eagle Idaho USA. 83616 T: 877.467.2862
More informationFROST FREE REFRIGERATOR INSTRUCTION MANUAL
FROST FREE REFRIGERATOR INSTRUCTION MANUAL Model No.: MCBR1010W MCBR1010S To ensure proper use of this appliance and your safety, please read the following instructions completely before operating this
More informationA. Product Data: Include rated capacities, furnished specialties and accessories.
BASE BID: SECTION 15542 FUEL-FIRED RADIANT HEATERS PART 1 - GENERAL 1.1 SUMMARY A. Furnish and install a Co-Ray-Vac Low Intensity Vented Infrared Radiant Vacuum Gas Heating System. System must be certified
More informationGARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1
GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E Figure 1 PET OWNERS WARNING: Health warning for some small pets, including birds, as they are extremely sensitive to the fumes produced
More informationWiring Instructions. High-Capacity Steam Humidifiers
Wiring Instructions for High-Capacity Steam Humidifiers Including Instructions for Compensating Humidistat and Safety Control Shutoff CONTRACTOR: Read these instructions before installing or servicing
More informationAgency-certified for outdoor use o Stainless steel exterior cabinet surrounds unit and forms a waterresistant
Standard Features & Accessories W. Beverage Dispenser Both models include Available built-in or as portable model Spacious interior is capable of holding up to 1/2 barrel 15.5 gal. (58.7 lit.) Includes
More informationSteam Humidification Light Commercial Applications. Better technology means better business.
Steam Humidification Light Commercial Applications Better technology means better business. Aprilaire Steam Humidifiers are built to last. Through extensive research and over 50 years expertise in humidification
More information