END003/004/214 DIGITAL THERMOSTAT Thank you for choosing END003/004/214 Temperature Controller.

Size: px
Start display at page:

Download "END003/004/214 DIGITAL THERMOSTAT Thank you for choosing END003/004/214 Temperature Controller."

Transcription

1 Please read this document carefully before using this product. The guarantee will be invalidated if the device is damaged by not following instructions detailed in the manual. The company shall not be responsible for any damage or losses however caused, which may be experienced as a result of the installation or use of this product. END3/4/4 DIGITAL THERMOSTAT Thank you for choosing END3/4/4 Temperature Controller. * ON / OFF Cooling control * 4 Relay Output for Cooling, Fan, AUX, Defrost (In the END3 product the defrost / aux output is taken from the same place and there are 3 relay outputs) * AUX Output can be set to Alarm or Lighting (Defrost output can not be used in END4 and END4 products.) RH * 3 NTC Probe inputs for Cell,Evaporator and Condenser * Digital Input (Door Switch) * Multifunction digital input (It is only available in END4.) * Offset value can be entered for NTC input * Compressor protection parameters can be entered. * In case of probe failure, output status can be set to % C F % AUX H.set! MF HACCP set ON, OFF or periodic. * Manuel fast cooling feature * Manuel or depending on Time and Evaporator defrost feature * Defrost dureation and intervals can be set. * Upper and Lower sepoint limits can be set. * Up to 3 HACCP alarm record can be stored. (9 alarm record in END4) * Real Time Clock feature (It is only available in END4.) * Android App (In Google Play Store END4 Connect) (It is only available at END4.) * Temperature unit can be displayed as F or C. * CE marked according to European Norms. * RS48 - ModBus RTU communication feature DIMENSIONS 6 46 x DEFR.! 3 ON 48 6 AUX 8 C F % / H. MF HACCP 8 Dimension unit is "mm". TECHNICAL FEATURES ENVIRONMENTAL CONDITIONS Ambient/Storage Temp C/ C (Without İcing) 8% Relative humidity for temperatures up to 3 C, decreasing linearly to % at 4 C. Relavite Humidity EN 69 Protection Class Height Max m Do not use the device in locations subject to corrosive and flammable gasses ELECTRICAL CHARACTERISTIC Supply Voltage 3V AC +% -%, /6Hz Max VA Power Consumption Connection. ve.7 mm²'lik screw-teral conneciton C ( F) Scale. C (Can be selected as.ºc orºc ) Sensitivity ± C Accuracy ±% Time Accuracy 4 Digits, 6x6mm 7 Segment Led, Warning Led. Display EN EMC Safety Requirements EN 6- (Pollution Degree, Overvoltage Category II) RELAYS Compressor Relay Output Fan Relay Output AUX Relay Output Defrost Relay Output (!)END3 does not exist for Resistive load NO 77V AC A, for inductive load hp V AC Relay Life Unload.. switching, 77V AC A rezistive load. switching. for Resistive load NO V AC 8A /hp 4V AC Relay Life Unload 3.. switching, V AC, 8A rezistive load. switching for Resistive load NO/NC V AC 8A, inductive load /hp 4V AC Relay Life Unload 3.. switching, V AC, 8A resistive load. switching for Resistive load NO/NC V AC 8A, inductive load /hp 4V AC Relay Life Unload 3.. switching, V AC, 8A rezistive load. switching OUTPUTS Control Control Method Hysterisis Setpoint Control,Compressor with digital Input,Defrost,Output Control Of Fan. On-Off Control Adjustable between..... C. /4 END3/4/4-EN74

2 FRONT PANEL COMMANDS LED LED/ BUTTON Description ON / OFF Led - If led is on, device don't work. - If led is off, device work. Lighting Led -if AUX is set as lighting and output is active, led is on. If ligthing activated by digital input,led is blinking. Compressor Led - If led is on, compressor is on. - If led is blinking, then protecting delay active - If led is off, compressor is off. MF Defrost Led - If led is on, defrost is in progress. - If led is blinking, dripping in progress. - If led is off, defrost is off. Fan Led - If led is on, fan is on. - If led is blinking, then protecting delay active - If led is off, fan is off. C Celcius Led - If it is on, temparature unit is Celcius. F Fahrenayt Led - If it is on, temparature unit is Fahrenheit. Multifunction Led -If AUX is set as other options (Check u Param) and output is active,led is on.if output activated by digital input, led is blinking. Clock Led -When the time and date are set, led blinks. (It is only available in END4.) Energy Saving Led -It is on when energy saving mode is active (It is only available in END4.) /H. Overcooling Led -If it is on,overcooling progress is active. -Show setpoint in run mode, -Show the value of the selected parameter in programg mode, confirm the value of the changed parameter. -Show and change humidification value in work mode,navigating between parameters, changing the value of a selected parameter in programg mode -Adjust low,medium and high humidity when pressed for 3 second HACCP Alarm Led - Blinks when a new alarm has occurred and turns on when the last HACCP Description -Show and reset alarm values in work mode,navigating between parameters, changing the value of a selected parameter. alarm is checked. Turns off if all alarm conditions are checked. Alarm Led - If it is on, there is an alarm or error condition.! Service Maintenance Led - If it is on, compressor has worked more than specified set. - If it is blinking, Android mobil device connected to the END4. (It is only available in END4.) AUX - Controlling of AUX output in work mode, controlling of keylock with ON button. - Only use for Aux output while parameter u =,, is set. DEFR -Controlling manel defrost in work mode ON -Controlling of device in work mode., -Return to work mode on configuration and other menus. -Controlling of keylock with AUX button. Viewing and Changing The Set Value -. Measurement Value In operating mode (without key lock). In this state, set value is changed with and keys. If no operation is performed for seconds or the key is pressed Switching the device on / off manually When in operation mode (no key lock), pressing the ON button for seconds will turn the indicator off / on and only the power led is on / off. In sleep mode, temperature measurement and control are disabled, outputs are turned off. Display of Evaporator and Condenser Temperatures Measurement value -. pb pb -. If you press the key while operating mode (no key lock),the menu that the alarm and other information shows is entered. From here, press the and keys and Pb (evaporator temperature) and Pb3 (condenser temperature) can be displayed by pressing the key. If no button is pressed for 6 seconds or if the ON key is pressed, the operation mode is returned. Locking and Unlocking Keys Measurement value Loc AUX & ON -. unl If the AUX & ON buttons are pressed together for seconds, the Loc message is displayed and the keys are locked. If the AUX & ON buttons are pressed again for seconds while the key is locked, the unl message is displayed and the key lock is opened and the normal Keys are unlocked. operation is in progress. When keys are locked, a Loc message is displayed if a key other than the key is pressed. Keys are locked. Setting of Configuration Parameters WORK MODE -. Measurement value & PA -9 PA & CONFIGURATION MENU Ca P Ca ON If the & keys are pressed together for 4 seconds in run mode (no key lock), the display shows the pass (PA) message. Press button and and keys to set pass to -9 and press button, then PA message again. Press & keys for 4 seconds at once to enter configuration menu. Press and keys to navigate through the menu and display the desired parameter message If the key is pressed, the value of that parameter is displayed. The value of the parameter can be changed with and buttons. When the PA message is displayed and you want to return to the operating mode at any point in the operation, you must press the ON button or wait for 6 seconds without pressing any key. /4 END3/4/4-EN74

3 Silencing the Buzzer When an alarm condition occurs, an audible alarm is triggered. The audible alarm can be switched off by pressing any key. Manuel Defrost Progress Manual defrost operation is started by pressing and holding DEFR key for 4 seconds in the operation mode (when the key is not locked, when overcooling is not working and the evap. temperature is lower than the defrost teration temperature).. Manuel Overcooling In the operating mode (when there is no key lock, the device is not in defrost mode and the dripping duration is not active), pressing key for 4 seconds starts or stops overcooling. At this time, the set value is reduced by the r parameter, and it operates according to the new set point set by the time set in parameter r6. During this time the defrost will not in progress. Humidification Operations (this function works if F = ) The principle of running In the low-scale humidification mode, the fan runs while the compressor is running. When the compressor stops, the fan stops with delay until the parameter F9 is reached. When the compressor is running in the medium-scale humidification mode, the fan starts to run. When the compressor stops, the fan stops with a delay of the parameter F9, then the fan stops for F4 parameter time, and runs periodically for F parameter time. In high-scale humidification mode the fan runs continuously. -. Measuremet Value rhl ON If the key is pressed in the run mode (without key lock), the message is displayed if the message rhl (low-scale humidification), rhm (mediumscale humidification) or rhh (high-humidity humidification) is valid.if no button is pressed for 3 seconds, it returns to the operation mode. Measuremet Value rhm ON -. If you press and hold the Up key for 4 seconds in run mode (without key lock), the display shows rhl (low-scale humidification), rhm (medium-scale humidification), rhh (highhumidity humidification) messages. The desired activation can be adjusted in this way.3 seconds no keylock are pressed or the ON key is pressed to return to the operating mode (the same operations can also be performed by changing the F6 parameter) Display of HACCP Alarms (For END3 and END4) Measuremet Value -. pb L AH id If you press the key while in the operation mode (no keylock),enter menu that the alarm and other information are displayed. From here, the L message is selected with and keys. The alarm conditions that occur when the key is pressed are listed. If the desired message is selected from the alarm messages generated by the and keys and the key is pressed, the information of the relevant alarm is started to be displayed in order. seconds no key is pressed or the operation mode is restored if ON key is pressed. Max. 3 alarms can be displayed The critical temperature value of the alarm Duration of the alarm (hour) Display of HACCP Alarms (For END4) pb L n4 Year Of Alarm Month of Alarm d Day of Alarm n h4 Hour Of Alarm id If you press the key while in the operation mode (no keylock),enter menu that the alarm and other information are displayed. From here, the L message is selected with and keys. The alarm conditions that occur when the key is pressed are listed. If the desired message is selected from the alarm messages generated by the and keys and the key is pressed, the information of the relevant alarm is started to be displayed in order. seconds no key is pressed or the operation mode is restored if ON key is pressed. Max. 9 alarms can be displayed.the number next to the alarm indicates the alarm sequence. If this number is, this alarm closest. y9 AH Minute of Alarm 4. The critical temperature value of the resulting alarm ta The date and time information of the alarm is displayed. dur Alarm duration time information n3 h Alarm duration shows the hour. Alarm duration utes. ah3 WORK MODE Measuremet Value -. ON Alarm type and index of alarm is displayed. Resetting Alarms -. Measurement value pb rl 49 If you press the key while in the operation mode (no key lock),enter menu that the alarm and other information are displayed. From here, the rl message is selected with the and keys. When the key is pressed and the and keys are set to 49 pass and the key is pressed, the message is displayed and the alarm statuses are reset and returned to the operation mode. When the rls message is displayed and you want to return to the operating mode at any point in the operation, you must press the ON or dont operation for seconds. When the alarms are reset, if there is an alarm running in the current state, the alarm status is canceled by starting from the beginning. 3/4 END3/4/4-EN74

4 Display of Compressor Run Time -. Measurement value pb CH 3 If the key is pressed,enter menu that the alarm and other information are displayed. The and keys are used to select the CH message. Pressing the key will display the running time of the compressor. When the CH message is displayed and you want to return to the operating mode at any point in the operation, you must press the ON or wait for seconds without pressing any key at any point in the operation. The compressor run time can be stored up to 9999 hours. Reset of Compressor Run Time -. Measurement value pb 49 rch If the key is pressed during operation mode (no keylock),enter menu that the alarm and other information are displayed. From here, the rch message is selected with the and keys. Pressing the key and pressing the key with the and keys adjusts the pass to 49" and the message is displayed and the compressor operation time is reset and the operation mode is reset. When the rch message is displayed and you want to return to the operating mode at any point in the operation, you must press the ON or wait for seconds without pressing any key at any point in the operation. Restore Factory Settings WORK MODE -. Measurement value & PA 49 & Pa def Press and hold the & keys together for 4 seconds in run mode (no key lock), the display shows the pass (PA) message. Press key and and keys to set pass to 49" and press key, then PA message again. Press and hold and keys for 4 seconds to display def message. Press key and and keys to set value to " and press key. the device starts to work again with the factory settings. Once the PA message is displayed and you want to return to the operating mode without any action, you must press or wait for seconds without pressing any key at any point in the operation. When the device is reset to factory settings, the device must be de-energized to see the effect of the parameters on the device. Display of Revision Number -. Measurement value & & r. If the & & keys are pressed together in run mode (no keylock), the display revision number is displayed. Error - Warning - Alarm - Information Messages Definitions Indicator pr. pr. pr.3 Indicator contents Cell Probe Error - Check the sensor connection. - Compressor works according to C4 and C parameters. - Defrost is not affected. Evaporator probe Error - Check the sensor connection. - If P3 is set to, defrost does not work.even if the F parameter 3 or 4 is selected, the fan operates as this parameter set. Condenser Probe Error - Check the sensor connection. - The condenser probe overheat alarm (COH) is not active. - Condenser probe overheating compressor shutdown alarm (CSd) is not active. contents Defrosting alarm switched off because max. time has been reached dfd - Check the parameters d, d3, d. - Any key must be pressed to return to operating mode. rhl Low-scale humidification message - To change the default settings, see Humidification Operations rhn Medium-scale humidification message - To change the default settings, see Humidification Operations Al Low temperature HACCP alarm - Check the parameters A, A, A. rhh High-scale humidification message - To change the default settings, see Humidification Operations AH High temperature HACCP alarm - Check parameters A4, A. Loc Keylock message - To change the key settings, see Locking and Unlocking Keys Operations. id COH Door HACCP alarm - Check the digital input. - Check parameters i, i, i, i4. Condenser overheated alarm - Check the condenser probe. - Check the C6 parameter. Err Cd Compressor blocked alarm - Check the C7 parameter. - Compressor and fan do not work. - Turning the device off and on is necessary to return to working PF Power supply interruption alarm - Check parameters A, A. (It is only available in END4.) ia uc İD Multifunction input alarm (It is only available in END4.) - Check the digital input. - Check parameters i, i6. rtc 4/4 Message to return to the factory settings and the related information is reset - The device starts working according to the factory settings. - If the transaction is done, new information starts to be stored. ENDA-KEY data transfer error -Expressions are not affected, parameters are not affected. ENDA-KEY data transfer message -The device works according to the new parameters. Pressure switch alarm (It is only available in END4.) - Check the digital input. - Check parameters i, i6, i7, i8 and i9. Clock error (It is only available in END4.) - re-set the day and real time - In this case the real-time functions will not work. END3/4/4-EN74

5 PARAMETER LIST CONFIGURATION PARAMETRES Working setpoint; see also r r r CA Offset cell probe -... CA Offset evaporator probe -... CA3 Offset condenser probe -... P P point = NO = YES P Temprature Unit C F P3 evaporator probe function probe absent defrosting probe and probe for evaporator fan thermostatisation probe for evaporator fan thermostatisation P4 enabling of condenser probe NO YES P8 delay in display of variations in temperature detected by the probes ds MAIN CONTROL PARAMETERS r Working setpoint differential.. 3. r Minimum working setpoint -6. r -. r Maximum working setpoint r. 8. r3 Locking of working setpoint calibration NO YES r4 Increase in temperature during Energy Saving function; see also i, i, HE and HE (This parameter is only available in END4) r Decrease in temperature during Overcooling function.. 3. r6 Duration of Overcooling function 4 r7 Minimum difference cell temperature - working setpoint (when the instrument switches on) such as to provoke the exclusion of the consequent value of the evaporator temperature among the ones used for the calculation of the relative average (if only d8=3)... r8 Cooling or heating action. Cooling Heating COMPRESSOR PARAMETERS C Delay in switching on of compressor after the insturment switches on 4 C The time required for the compressor to restart after the Pr" fault has elapsed. 4 C Minimum duration of compressor switch off time 4 C3 Minimum duration of compressor switch on time sec 4 C4 Duration of compressor switch off during cell probe error (code Pr ) 4 C Duration of compressor switch on during cell probe error (code Pr ) 4 C6 Condenser temperature is higher than that at which the condenser overheating alarm is activated (code COH - hysteresis C ).. 6. C7 Condenser temperature is higher than the limit at which the compressor blocked alarm is activated (code CSd hysteresis C ) C8 Compressor alarm delay locked (code CSd ) hr C Number of operating hours is higher than the limit at which the need for maintenance is signaled. = function absent /4 END3/4/4-EN74

6 DEFROST PARAMETERS d If d8 =, or, defrosting interval If d8 = 3, maximum defrost interval hr 99 6 = interval defrosting will never be activated d of defrosting = ELECTRIC - during defrosting the compressor will remain off and the defrosting output will be activated; evaporator fan activity will depend on parameter F = BY HOT GAS - during defrosting the compressor will be switched on and the defrosting output will be activated; evaporator fan activity will depend on parameter F = VIA STOPPING OF COMPRESSOR - during defrosting the compressor will remain switched off and the defrosting output will remain disactivated; evaporator fan activity will depend on par. F d If the evaporator temperature is greater than this value, defrost does not operate (P3 = ) d3 Defrost Duration P3 = or, defrosting duration P3 =, maximum defrosting duration 99 d4 Defrosting when instrument is switched on = NO = YES d The time it takes for the defrost to become active after device is energized 99 d6 Temperature displayed during defrosting cell temperature "SP + r" is shown if cabin temperature is less than "SP + r", cell temperature is shown if cell temprature is bigger than SP+r During the defrost, "def" flashes on the screen d7 Dripping duration (during dripping the compressor will remain switched off and the defrosting output will remain disactivated; if d6 =, evaporator fan activity will depend on parameter F; if d6, the evaporator fan will remain switched off) d8 Defrost activation type defrosting will be activated once the instrument has altogether been running for time d defrosting will be activated once the compressor has altogether been switched on for time d defrosting will be activated once the evaporator temperature has altogether been below temperature d9 for time d(p<d9) 3 ADAPTABLE -Learning ModeIn this step no defrosting is performed and the ideal evaporator temperature average of the system is calculated.(check r7,d7,i,i) -Normal Work Mode - Cond If the sum of the time when Evap. temparature is lower than the calculated Evap. temperature is greater than the set value of d8, defrost becomes active. - Cond evaporatör probu sıcaklığı,hesaplanan evap.sıcaklığı- d9 par. farkından küçük ise defrost aktif olur. - Cond3After rapid cooling, the defrost becomes active. - Cond4If the door has been opened more than the time set by the relevant parameters, defrost will be activated (i3, i4 must be checked) *After the defrost is activated, it returns to the learning mode again and these operations are carried out periodically. 4 The real time defrost will be active at the times specified in the parameters.(h...h6) 3 d9 Evaporator temperature is higher than that at which the defrost interval counter is suspended (only if d8 = ) () d Defrosting alarm switches off once maximum time limit has been reached (dfd ve Pr) Yes d Minimum time that the compressor must be switched on before defrosting can be activated (only if d = ) 99 d6 Predripping duration (during predripping the compressor will remain switched off, the defrosting output will be activated and the evaporator fan will remain switched off) 99 d7 Number of evaporator temperature values used for the calculation of the relative average (for the defrost activation; only if d8 = 3); also look at r7, i and i d8 Defrosting interval (only if d8 = 3 and for condition ) = defrosting for condition will never be activated 99 4 d9 Evaporator temperature above which the defrost is activated (relative to the evaporator temperatures average, or evaporator temperatures average - d9 ) (only if d8 = 3 and for condition ); also look at d d Minimum consecutive time the compressor must be switched on such as to provoke the defrost activation the defrost will never be activated 4 d Minimum consecutive time the compressor must be switched on after the insturment switches on(on condition that the difference cell temp. - working setpoint is higher temperature r7) and after function Overcooling is activated such as to provoke the defrost activation (This parameter is only available in END4) d Evaporator temp. above which the defrosting interval is suspended (also look at d8,d7)... d3 Evaporator temperatures average increase during function Energy Saving (for defrost activation; only if d8 = 3); also look at d7 (This parameter is only available in END4)... () Upper limit is 3" in END3 and END4, upper limit is 4" in EN4. 6/4 END3/4/4-EN74

7 ALARM PARAMETERS A Temperature associated with the imum temperature alarm (code AL ) = cell temperature = evaporator temperature A Temperature below that at which the imum temperature alarm is activated A of imum temperature alarm (code AL ) = alarm absent = relative to working setpoint (that is working setpoint - A ; consider A without sign) = absolute (that is A) A4 Temperature higher than that at which the maximum temperature alarm is activated A of maximum temperature alarm (code AH ) = alarm absent = relative to working setpoint (that is working setpoint + A4 ; consider A without sign)) = absolute (that is A4) A6 Delay in maximum temperature alarm (code AH ) after the instrument is switched on 4 A7 Temperature alarm delay (code AL and code AH ) 4 3 A8 Delay in maximum temperature alarm (code AH ) following the conclusion of defrosting and following the conclusion 4 6 A9 Delay in maximum temp. alarm( AH ) following the disactivation of the door microswitch 4 6 A Duration of interruption in the power supply that occurs when the instrument has been running for long enough to cause the storage of the power interruption alarm when the power supply is restored. (code PF ) (This parameter is only available in END4) 4 3 A Differential of parameters A and A4... A Kind of signal for power interruption alarm (code PF ); also look at A = the alarm will not be signalled = the display will show the code PF flashing and the buzzer will be activated = the display will show the code PF flashing and the buzzer will be activated (this last on condition that the power interruption duration is higher than time A) (This parameter is only available in END4) FAN PARAMETERS-/ F Evaporator fan activity during normal operation = switched off = switched on; see also F3, F4 and i = in parallel with the compressor; see also F9, F3, F4 and i 3 = dependent on F (6) 4 = switched off if the compressor is switched off, dependent on F if the compressor is switched on; see also F9 = dependent on F6; see also F, F9 and F F Evaporator temperature above the limit at which the evaporator fan is switched off (only if F = 3, 4 or ); see also F8 F Evaporator fan activity during defrosting and dripping = switched off = switched on (setting parameter d7 to is recommended) = dependent on F F3 Maximum duration of evaporator fan disactivation; see also F7 (during evaporator fan desactivation the compressor can be switched on,the defrosting output will remain disactivated and the evaporator fan will remain switched off) (This parameter is only available in END4) F4 Time duration that evaporator fan is switched off during operation for a low percentage of relative humidity when the compressor is switched off; see also F (only if F = ) sec 4 6 F Time duration that evaporator fan is switched on during operation for a low percentage of relative humidity when the compressor is switched off; see also F4 (only if F = ) sec 4 F6 Operation for low or high percentage of relative humidity (only if F = ) = LOW RELATIVE HUMIDITY - the evaporator fan will operate in parallel with the compressor = MEDIUM RELATIVE HUMIDITY - the evaporator fan will operate in parallel with the compressor; see also F4 and F = HIGH RELATIVE HUMIDITY - the evaporator fan will always be switched on F7 Evaporator temperature below limit at which the evaporator fan is disactivated (relative to working setpoint, that is working setpoint + F7 );see also F3 (This parameter is only available in END4) /4 END3/4/4-EN74

8 FAN PARAMETERS-/ F8 Parameter F differential (Check F parameter ) F9 Delay in the switching off of evaporator fan following the switching off of the compressor (only if F =, 4 and ) DEF... sec 4 F Evaporator temperature below the limit at which the evaporator fan is switched off (only if F = 3, 4 or ); see also F F Condenser temperature above that at which the condenser fan is switched on ( F +. C/4 F, only if u = 6 and provided the compressor is switched on); see also F F Delay in switching off of the condenser fan following the switching off of the condenser (only if u=6) (see also F) sec 4 3 F3 Time the evaporator fan remains turned off during function Energy Saving; see also F4 and i (only if F = or ) (This parameter is only available in END4) 4 F4 Time the evaporator fan remains turned on during function Energy Saving; see also F3 and i (only if F = or ) (This parameter is only available in END4) 4 DIGITAL INPUT PARAMETERS - / i Effect caused by the activation of the door microswitch input no effect the compressor and evaporator fan will be switched off the evaporator fan will be switched off 3 the cell light will be switched on (only if u =, until the input is disactivated) 4 the compressor and evaporator fan will be switched off (at most for time i3 or until the input is disactivated) and the cell light will be switched on (only if u =, until the input is disactivated the evaporator fan will be switched off (at most until time i3 or until the input has been deactivated) and the cell light will be switched on (only if u =, until the input is deactivated) () NOT 3,4 and options are only available in END4 i of door microswitch input contact = normally open (active input with closed contact) = normally close (active input with open contact) i Delay in signaling of door microswitch input alarm (code id ) - = the alarm will not be signaled i3 Maximum duration of the effect caused by activation of the door microswitch on the compressor and the evaporator fan -= the effect will last until the input is disactivated i4 i - - Storage of door microswitch input alarm (code id ) () = NO = YES Effect caused by the activation of the multifunction input (This parameter is only available in END4) 6 no effect SYNCHRONISATION OF DEFROSTING PERIODS - once time d has passed defrosting will be activated ACTIVATION OF ENERGY SAVING FUNCTION - the Energy Saving function will be activated (until the input is disactived), provided the Overcooling function is running; see also r4 3 ACTIVATION OF MULTIFUNCTION INPUT ALARM - once time i7 has passed the display will show the flashing code ia and the buzzer will be activated (until the input is disactivated) 4 ACTIVATION OF THE PRESSURE SWITCH ALARM - the compressor will be switched off, if u = 6 the condenser fan will be switched on, the display will show the flashing code ia and the buzzer will be activated (until the input is disactivated) when the input has been activated the number of times established with parameter i8 the regulators will be switched off, if u = 6 the condenser fan will be switched on, the display will show the flashing code isd and the buzzer will be activated (until the input is disactivated and the instrument is switched off and re-started or until the power supply is interrupted); see also i7 and i9 SWTICHING ON THE AUXILIARY OUTPUT - the auxiliary output will be switched on (only if u=, until the input is disactivated) 6 SWITCHING OFF THE INSTRUMENT - the instrument will be switched off (until the input is disactivated) i6 of mutlifunction input contact (This parameter is only available in END4) = normally open (active input with closed contact) = normally close (active input with open contact) i7 If i = 3, multifunction input alarm delay (code ia ) If i = 4, delay in compressor switching on after the disactivation of the multifunction input (This parameter is only available in END4) i8 Number of multifunction input alarms (code ia ) such to cause a pressure switch alarm (code isd ) (if i = 4) = alarm absent (This parameter is only available in END4) () Upper limit is in END3 and END4, upper limit is in END4. 8/4 END3/4/4-EN74

9 DİGITAL INPUT PARAMETERS - / i9 Time that must pass in absence of mutlifunction output alarms (code ia ) so that the alarm counter is reset (only if i = 4) (This parameter is only available in END4) i Time without activations of the door switch input (on condition that the cabinet temperature has reached the working setpoint) in order that function Energy Saving is activated automatically (it has effect on the evaporator fan only if F = or ) = the function will never automatically be activated (This parameter is only available in END4) i Minimum time the door switch input must be activated such as to provoke the exclusion of the consequent value of the evaporator temperature among the ones used for the calculation of the relative average (for the defrost activation; only if d8 = 3); also look at d7 sec 4 i Minimum time the door switch input must be activated altogether such as to provoke the exclusion of the consequent value of the evaporator temp. among the ones used for the calculation of the relative average (for the defrost activation; only if d8 = 3); also look at d7 sec 4 6 i3 Number of door switch input activations such as to provoke the defrost activation = the defrost will never be activated because of the door switch input activation 4 8 i4 Minimum duration of the door switch imput activation such as to provoke the defrost activation = the defrost will never be activated because of the door switch input activation 4 3 BİRİM ENAZ ENÇOK BAŞ. AUX ÇIKIŞI PARAMETRELERİ AD PARAMETRE AÇIKLAMASI u Controlling of AUX Output Cell light - in this case the AUXILIARY key and parameters i and u will be activated Demister resistors - in this case the AUXILIARY key and parameter u6 will be activated Auxiliary output - in this case the AUXILIARY key and params. i and u will be activated 3 Alarm outputs - in this case parameter u4 will be activated 4 Door resistors - in this case parameter u will be activated Evaporator valve - in this case parameters u7 and u8 will be activated 6 Condenser fan - in this case parameters P4, F and F will be activated 7 Defrost out (NOT There isn t 7. option in END4 and END4.) 7 u Enabling of manual switch on/switch off of the cell light or the auxiliary output when the instrument is switched off (only if u = or ) = YES u4 Enabling of alarm output disactivation with the silencing of the buzzer (only if u = 3) = YES u Cell temperature below that at which the door resistors are switched on (if u = 4 ) u6 Operating time of demistor resistors (only if u = ) u7 Cell temperature below that at which the evaporator valve is disactivated (only if u=) u8 of evaporator valve contact (only if u= ) normally open (valve active with contact closed) normally closed (valve active with contact open) u9 Enabling of buzzer Inactive Active () 7 () () Upper limit is 7" in END3, upper limit is 6" in END4 and END4. () Default value is 7" in END3, default value is " in END4 and END4. REAL-TIME ENERGY SAVING PARAMETERS (only in END4) HE Time of activation of the Energy Saving in real time function; see also r4 and HE sadk 39 3 HE Duration of the Energy Saving in real time function; see also r4 and HE = the Energy Saving in real time function will not be activated sadk /4 END3/4/4-EN74

10 REAL-TIME DEFROST PARAMETERS (only in END4) Hd time of activation of first defrosting period in real time (only if d8 = 4) = the first defrosting in real time will not be activated sadk 39 Hd time of activation of second defrosting period in real time (only if d8 = 4) = the second defrosting in real time will not be activated sadk 39 Hd3 time of activation of third defrosting period in real time (only if d8 = 4) = the third defrosting in real time will not be activated sadk 39 Hd4 time of activation of fourth defrosting period in real time (only if d8 = 4) = the fourth defrosting in real time will not be activated sadk 39 Hd time of activation of fifth defrosting period in real time (only if d8 = 4) = the fifth defrosting in real time will not be activated sadk 39 Hd6 time of activation of sixth defrosting period in real time (only if d8 = 4) = the sixth defrosting in real time will not be activated sadk 39 4 DEF DATA-LOGGING PARAMETRES (only in END4) uien Communication Modbus Wifi re logging interval re Temperature selection for data-logging Cabin temperature Evaporator temperature Condenser temperature 4 Cabinet and evaporator temperature All SECURITY PARAMETERS (only in END4) pa User Pass for Android Application pa Service Pass for Android Application DEF Rs48 MODBUS COMMUNICATION PARAMETERS LA Slave Device Address Lb BaudRate Bps ENDA-KEY Parametre Aktarımı TRANSFERRING THE PARAMETERS FROM ENDAKEY TO DEVICE While in "Running Mode", if AUX key on device or Read button on ENDAKEY is pressed, dl message appears on display and parameters are read and transferred to the device. If the parameter transfer is successful, the " ref " message appears and the device begins to work with the loaded parameter values. If the parameters are wrong, incorrect or " ENDAKEY " is faulty, " Err " message appears. Parameters will not be changed on device. Read button TRANSFERRING THE PARAMETERS FROM DEVICE TO ENDAKEY While in "Running Mode", if DEFR. key is pressed on device, ul message appears on display and parameters are read and transferred to the device. If process success, uc message appears. In case of failure, " Err" message appears. Parameters will not be changed on device. NOTE No power-up required for transfering the parameter by using "ENDAKEY". For long battery life, "ENDAKEY" must be disconnected from device after the transferring process. NOTE Please specify at order ENDAKEY if required. /4 END3/4/4-EN74

11 CONNECTION DIAGRAM END3/4/4 is intended for installation in control panels. Make sure that the device is used only for intended purpose. The electrical connections must be carried out by a qualified staff and must be according to the relevant locally applicable regulations. During an installation, all of the cables that are connected to the device must be free of electrical power. The device must be protected against inadmissible humidity, vibrations, severe soiling and make sure that the operation temperature is not exceeded. The cables should not be close to the power cables or components. 3 4 K 6 DOOR INPUT RS48 CON. GND AUX-DEFROST V 8A~ CONDENSER NTC CELL NTC FAN COMP V 8A~ 77V A~ 3V AC /6Hz VA N L EVAPORATOR NTC END3 DIGITAL THERMOSTAT 7 K A B 9 Made in Turkey K3 3 4 K DOOR INPUT GND CONDENSER NTC AUX DEFROST V 8A~ V 8A~ EVAPORATOR NTC FAN COMP V 8A~ 77V A~ 3V AC /6Hz VA N L CELL NTC END4 DIGITAL THERMOSTAT 7 8 K RS48 CON. A B 9 Made in Turkey K4 K3 3 4 K Line Neutral MULTIFUNC. INPUT A B Made in Turkey K4 K3 Fuse F ma V AC RS48 CON. DOOR INPUT GND CONDENSER NTC AUX DEFROST V 8A~ V 8A~ K SPLY 84-3V AC /6Hz 4VA 6 CELL NTC FAN COMP V 8A~ 77V A~ 3V AC /6Hz VA N L EVAPORATOR NTC END4 DIGITAL THERMOSTAT Note Switch 3V AC Supply ) Mains supply cords shall meet the requirements of IEC 67 or IEC 64. ) In accordance with the safety regulations, the power supply switch shall bring the identification of the relevant instrument and it should be easily accessible by the operator. Fuse should be connected Cable size,mm² Equipment is protected throughout by DOUBLE INSULATION. Holding screw.4-.nm A Slave Device- Max. 47 slave devices B + B + + A - B Slave Device- - B + Ohm Master A Device Slave A Device Ohm ModBus COMMUNICATION WIRING SCHEME The start and end of the communication line must be terated with a Ohm resistor. /4 END3/4/4-EN74

12 END3 - END4 DIGITAL THERMOSTAT MODBUS PROTOCOL ADDRESS MAP. HOLDING REGISTERS Holding Register Adresses Content d x System control set value () d x d x 3d x3 4d Parameter R/W Permission P Cabinet probe offset value () CA Evaporator probe offset value () CA Condenser probe offset value () CA3 x4 Evaporator probe function Not Applicable for defrost and fan control for fan control P3 d x Temperature value refresh time to be displayed P8 6d x6 System control setpoint hysteresis () r 7d x7 System control set value lower limit () r 8d x8 System control set value upper limit () r 9d x9 In fast cooling mode the set value is reduced by this value () r d xa Fast cooling mode time r6 Ideal evap. during the calculation (cabin temperature-set) If the value is bigger than the value, the measured value of the evap. () r7 d xb d xc The time it takes for the compressor to enter the circuit after power is applied C 3d xd In order for the compressor to restart after the Pr fault has elapsed time to pass. C 4d xe After the stop,time that the compressor must go through before it can start again. C d xf The imum time required for the compressor to run. C3 6d x Compressor dead time in case of cabinet probe failure C4 7d x Compressor open time in case of cabinet probe failure C If the condenser temperature is higher than this value, the condenser temperature alarm COH "becomes active(hysteresis C) () C6 C7 8d x 9d x3 If the condenser temperatures are higher than this value, the compressor temperature alarm "Csd" becomes active(hysterisis C) () d x4 The duration of the alarm after the compr. alarm "CSd" has been activated C8 d x Compressor operating time limit C d x6 Time between two consecutive defrosts D 3d x7 Defrost type Electric Gas Compressor off D 4d x8 If the evaporator temp is bigger than this value, defrost will not work() D d x9 Defrost time D3 6d xa The time it takes for the defrost to become active after it is energized D Displayed during display during defrost Cabin temperature "SP + r" if cabin temperature is less than "SP + r", cabin temperature "SP + r" the cabin temperature is shown the "def" mark flashes D6 7d xb 8d xc Drip discharge time D7 D8 D9 9d xd Defrost activation type time between two defrosts it will be ignored. time between two defrosts only compressor as long as it works. time between two defrosts only evaporato the probe temperature is reduced as long as the condition is less than d9 par. 3 Adaptive defrost 4 Real-time defrost 3d xe If evap. probe temperature is greater than this parameter value, defrost counter will not decrease () 3d xf For the defrosting to be active, the time required for the compressor. D 3d x Pre-melting time D6 33d x The number of samples used for evaporator probe temperature averaging D7 D8 34d x The time the evap. temperature is below the calculated ideal evap. temperature defrost is activated if the sum has reached this set time. 3d x3 Evap. probe temperature is less than "calculated evap. temperature-d9" defrost is active() D9 D D a 36d x4 Two consecutive compressors in order to activate defrosting.time 37d x Adaptive defrost evap. probe teration temperature () 38d x6 Min temperature alarm (AL) activation value () /4 END3/4/4-EN74

13 END3 - END4 DİJİTAL TERMOSTAT Holding Register Adresleri Verinin İçeriği Veri Tipi Parametre Okuma /Yazma İzni Adı 39d x7 Min temperature alarm (AL) tipi No Alarm Alarm activation value "SP- A " Alarm activation value becomes A 4d x8 Max. Temperature alarm (AH) activation value () 4d x9 Max. Temperature alarm (AH) type A A A4 4d xa Maximum temperature alarm (AH) display delay after power up A6 43d xb Temperature alarm (AH,AL) display delay A7 44d xc After the defrost has finished, the max. temperature alarm (AH) alarm display delay A8 4d xd A9 46d xe After the door alarm has been deactivated, the Max. temp. alarm (AH) alarm display delay Max Temperature alarms (AL, AH) hysteresis () A f F F 47d xf Evaporator fan activity during normal operation = switched off = switched on; see also F3, F4 and i = in parallel with the compressor; see also F9, F3, F4 and i 3 = dependent on F (6) 4 = switched off if the compressor is switched off, dependent on F if the compressor is switched on; see also F9 = dependent on F6; see also F, F9 and F 48d x3 Fan stop temperature. If the evaporator temperature is above this value, fan will not work. () 49d x3 Evaporator fan activity during defrosting and dripping = switched off = switched on (setting parameter d7 to is recommended) = dependent on F d x3 Time duration that evaporator fan is switched off during operation for a low percentage of relative humidity when the compressor is switched off F4 d x33 Time duration that evaporator fan is switched on during operation for a low percentage of relative humidity when the compressor is switched off F d x34 F6 3d x3 Fan stop temperature hysteresis () F8 The time required for the fan to shut down after the compressor has switched off F9 F Operation for low or high percentage of relative humidity (only if F = ) 4d x36 = LOW RELATIVE HUMIDITY = MEDIUM RELATIVE HUMIDITY = HIGH RELATIVE HUMIDITY d x37 If the evaporator temperature is below the value set by this parameter, fan will not work () 6d x38 If the condenser probe temperature is greater than the value set by this parameterthe fan works () F 7d x39 Time to close the fan due to the condenser probe 8d x3a F Effect caused by the activation of the door microswitch input no effect the compressor and evaporator fan will be switched off the evaporator fan will be switched off 3 the cell light will be switched on (only if u =, until the input is disactivated) 4 the compressor and evaporator fan will be switched off (at most for time i3 or until the input is disactivated) and the cell light will be switched on (only if u =, until the input is disactivated the evaporator fan will be switched off (at most until time i3 or until the input has been disactivated) and the cell light will be switched on (only if u =, until the input is disactivated) I 9d x3b Door digital input alarm (Id) display delay I 6d x3c After the door digital input is activated, the effect of compressor and fan max time I3 6d x3d imum time the door switch input must be activated such as to provoke the exclusion of the consequent value of the evaporator temp. among the ones used for the calculation of the relative average I 6d x3e imum time the door switch input must be activated altogether such as to provoke the exclusion of the consequent value of the evaporator temp. among the ones used for the calculation of the relative average I 63d x3f number of door switch input activations such as to provoke the defrost activation I3 64d x4 imum duration of the door switch imput activation such as to provoke the defrost activation I4 Controlling of AUX Output 6d x4 66d x4 67d x43 68d x Cell light - in this case the AUXILIARY key and parameters i and u will be activated Demister resistors - in this case the AUXILIARY key and parameter u6 will be activated Auxiliary output - in this case the AUXILIARY key and params. i and u will be activated Alarm outputs - in this case parameter u4 will be activated Door resistors - in this case parameter u will be activated Evaporator valve - in this case parameters u7 and u8 will be activated Condenser fan - in this case parameters P4, F and F will be activated Defrost out u cell temperature below that at which the door resistors are switched on u operating time of demistor resistors u6 u7 cell temperature below that at which the evaporator valve is disactivated 3/4 END3/4/4-EN74

14 END3 - END4 DIGITAL THERMOSTAT. INPUT REGISTERS Input Register Adresleri Content Parameter R/W Permission d x Measured cabinet probe temperature value ( C / F) d x Measured evaporator probe temperature value ( C / F) d x Measured condenser probe temperature value ( C / F) In the Holding and Input Register parameters, integer types are defined as signed integers, and these parameters are in decimal (A parameter of "4." will be read as "4".) The time-related parameters " sec" read as sec and "hr " read as utes. END3 - END4 DIGITAL THERMOSTAT.3 DISCRETE INPUTS Discrate Inputs Adresleri Content Parameter R/W Permission d x bit Compressor relay output status (OFF; =ON) d x bit Fan relay output status (=OFF; =ON) d x bit AUX relay output status (=OFF; =ON) 3d x3 bit Defrost relay output status (=OFF; =ON) END3 - END4 DIGITAL THERMOSTAT.4 COILS Coil Adresleri d x d x d x 3d x3 4d x4 d Content Parameter R/W Permission P Temperature = C = F P Use Condenser probe = NO = YES P4 System control set value change lock operation = NO = YES r3 System Control = cooling = heating r8 x Start Defrost with energy = NO = YES d4 6d x6 Device manual on-off button control 7d x7 If the defrost alarm has reached the max display time = OFF = ON d 8d x8 Min temperature alarm (AL) control probe = cell temp. = evap. temp. A 9d x9 Door digital input activation = normally open = normally close i d xa Door digital input alarm (Id) storage = NO = YES i4 d xb Switching the AUX outputs off and on while manual is off. = NO = YES u d xc Cancel alarm output and silence buzzer when alarm occurs = NO = YES u4 3d xd Evaporator output activation = normally open = normally close u8 4d xe Activating the buzzer u9 point display = NO = YES = NO = YES 4/4 END3/4/4-EN74

15 END4 DIGITAL THERMOSTAT MODBUS PROTOCOL ADDRESS MAP. HOLDING REGISTERS Holding Register Adresses Content Parameter R/W Permission d x System control set value () P d x Cabinet probe offset value () CA d x Evaporator probe offset value () CA 3d x3 Condenser probe offset value () CA3 4d x4 Evaporator probe function Not Applicable for defrost and fan control for fan control P3 d x Temperature value refresh time to be displayed P8 6d x6 System control setpoint hysteresis () r 7d x7 System control set value lower limit () r 8d x8 System control set value upper limit () r 9d x9 Temperature increase during energy saving function () r4 d xa In fast cooling mode the set value is reduced by this value () r d xb Fast cooling mode time r6 Ideal evap. during the calculation (cabin temperature-set) If the value is bigger than the value, the measured value of the evap. () r7 d xc 3d xd The time it takes for the compressor to enter the circuit after power is applied C 4d xe In order for the compressor to restart after the Pr fault has elapsed time to pass. C d xf After the stop,time that the compressor must go through before it can start again. C 6d x The imum time required for the compressor to run. C3 7d x Compressor dead time in case of cabinet probe failure C4 C 8d x Compressor open time in case of cabinet probe failure 9d x3 If the condenser temperature is higher than this value, the condenser temperature alarm COH "becomes active(hysteresis C) () C6 C7 d x4 If the condenser temperatures are higher than this value, the compressor temperature alarm "Csd" becomes active(hysterisis C) () d x The duration of the alarm after the compr. alarm "CSd" has been activated C8 d x6 Compressor operating time limit C 3d x7 Time between two consecutive defrosts D 4d x8 Defrost type Electric Gas Compressor off D d x9 If the evaporator temp is bigger than this value, defrost will not work() D 6d xa Defrost time D3 D 7d xb The time it takes for the defrost to become active after it is energized 8d xc Displayed during display during defrost Cabin temperature "SP + r" if cabin temperature is less than "SP + r", cabin temperature "SP + r" the cabin temperature is shown the "def" mark flashes D6 9d xd Drip discharge time D7 D8 3d xe Defrost activation type time between two defrosts it will be ignored. time between two defrosts only compressor as long as it works. time between two defrosts only evaporato the probe temperature is reduced as long as the condition is less than d9 par. 3 Adaptive defrost 4 Real-time defrost 3d xf If evap. probe temperature is greater than this parameter value, defrost counter will not decrease () D9 3d x For the defrosting to be active, the time required for the compressor. D 33d x Pre-melting time D6 34d x The number of samples used for evaporator probe temperature averaging D7 3d x3 The time the evap. temperature is below the calculated ideal evap. temperature defrost is activated if the sum has reached this set time. D8 36d x4 Evap. probe temperature is less than "calculated evap. temperature-d9" defrost is active() D9 37d x Two consecutive compressors in order to activate defrosting.time D 38d x6 After the device has been switched on,consecutive time that the compressor must be active D /4 END3/4/4-EN74

Label Displayed temperature Pb1 if the P4 parameter is set to 0, 1 or 2, room temperature if the P4 parameter is set to 3, incoming air temperature

Label Displayed temperature Pb1 if the P4 parameter is set to 0, 1 or 2, room temperature if the P4 parameter is set to 3, incoming air temperature EVCO S.p.A. EV3B24 Data sheet ver. 1.0 Code 1043B24E104 Page 1 of 6 PT 12/15 EV3B24 Basic controller for low temperature bottle coolers, cabinets, refrigerated cabinets, tables and pizza counters, with

More information

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173) Evco S.p.A. Code 104K204E05 page 1/5 EVK204 Digital controller for ventilated refrigerating units, with HACCP and Energy Saving functions version 1.05 GB ENGLISH 1 PREPARATIONS 1.1 Important Please read

More information

ENDA EHTC HUMIDITY AND TEMPERATURE CONTROLLER. Thank you for choosing ENDA EHTC Relative Humidity and Temperature Controller devices.

ENDA EHTC HUMIDITY AND TEMPERATURE CONTROLLER. Thank you for choosing ENDA EHTC Relative Humidity and Temperature Controller devices. * 4-Digits, Primary and Secondary display * 0... 00 RH Humidity measurement * -40... +5 Temperature measurement * Relay outputs for Temperature and Humidity control * Selectable heating or cooling control

More information

Dixell Installing and Operating Instructions release 7.0

Dixell Installing and Operating Instructions release 7.0 XR160C - XR160D - XR170C - XR170D - XR162C - XR172C CONTENTS 1. GENERAL WARNING 2 1.1 Please read before using this manual 2 1.2 Safety Precautions 2 2. GENERAL DESCRIPTION 2 3. CONTROLLING LOADS 2 3.1

More information

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF:

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF: EC 6-295P220S001 smart guide ON-OFF digital controller for ventilated refrigerating units Version 1.01 of 15 th March 2005 File ec6295p220s001_eng_v1.01.pdf PT EVCO S.r.l. Via Mezzaterra 6, 32036 Sedico

More information

Advanced temperature controller for cold rooms

Advanced temperature controller for cold rooms GB 1652H4A02 Ed.03 AKO-16524A Advanced temperature controller for cold rooms User manual Index Page Presentation...3 Warnings...3 Maintenance...3 Description...4 Installation...6 Wiring...7 Installation

More information

ER52 - Evaporator Controller

ER52 - Evaporator Controller ER52 - Evaporator Controller Electronic Refrigeration Line Product Bulletin Devices are standalone digital controller for static or ventilated refrigeration units working at positive temperatures. They

More information

MO n : 12JMC rév A

MO n : 12JMC rév A CTT8 MO n : rév A Page 2 / 18 MODIFICATIONS Rev. Description Date Checked by Approuved by Z Creation 2012/02/12 JMC LA A First issue 2012/02/14 JMC LA INDEX Page 3 / 18 GENERALITY 4 INTRODUCTION 4 ACCESSORIES

More information

Thermometers and temperature controllers

Thermometers and temperature controllers D144H002 Ed.07 GB Thermometers and temperature controllers User Manual Contents AKO Electromecánica thanks and congratulates you for purchasing our product, in whose development and manufacture the most

More information

CTT8 TEMPERATURE MONITOR DEVICE

CTT8 TEMPERATURE MONITOR DEVICE INSTRUCTION MANUAL IM302-U v2.3 CTT8 TEMPERATURE MONITOR DEVICE GENERALITY The device of control temperatures CTT8 is used in the control of electric machine, transformer, motor, etc. where it s possible

More information

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE Release January 2001 CONTENTS 1.0 GENERAL CHARACTERISTICS... 4 1.1 MAIN CHARACTERIS TICS... 4 2.0 USER INTERFACE (CODE C5121230)... 5 2.1 DISPLAY... 5 2.2 MEANING OF THE LEDS...

More information

Refrigerated air dryers

Refrigerated air dryers Refrigerated air dryers OPERATING AND MAINTENANCE MANUAL Original instructions 38178800319 OPERATING AND MAINTENANCE MANUAL - Contents 1 CONTENTS CONTENTS... 1 Chapter 1 IDRY ELECTRONIC CONTROLLER...

More information

Updated: 17/03/2010 ELECTROLUX. CAREL ir33. Quick reference Handbook. Ver. 1.1 Eng. Pag.1/12

Updated: 17/03/2010 ELECTROLUX. CAREL ir33. Quick reference Handbook. Ver. 1.1 Eng. Pag.1/12 CAREL ir33 Quick reference Handbook Pag.1/12 MAIN FEATURES OF THE INSTRUMENT USER INTERFACE 1. ON/OFF switch button UP button to increase temperature values 2. DOWN button to decrease values - Activates/deactivates

More information

Temperature and moisture controller for cold room store

Temperature and moisture controller for cold room store GB 1662H402 Ed.01 AKO-16624 Temperature and moisture controller for cold room store User Manual Index Page Warnings...3 Wiring...3 Maintenance...3 Description...4 Installation...6 Initial configuration...7

More information

EXD-HP1/2 Stand-alone Superheat/Economizer Controller

EXD-HP1/2 Stand-alone Superheat/Economizer Controller Technical Bulletin EXD-HP1/2 are stand-alone universal superheat and or economizer controllers for heat pumps, heating units, air conditioning and precision cooling such as telecom and shelter applications.

More information

XC1008D -XC1011D- XC1015D and VGC810

XC1008D -XC1011D- XC1015D and VGC810 Electronic Controller for Compressor Racks XC1008D -XC1011D- XC1015D and VGC810 Instructions Manual INDEX 1. GENERAL WARNING 4 1.1 PLEASE READ BEFORE USING THIS MANUAL 4 1.2 SAFETY PRECAUTIONS 4 2. WIRING

More information

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort User manual CLIMATIC 2/4 - Controller Providing indoor climate comfort MUL35E-56 9-26 INDEX CONTENTS PAGE INDEX 1 GENERAL DESCRIPTION 2 THE KEYPAD, Climatic 2 3 THE KEYPAD, Climatic 4 4 THE KEYPAD REMOTE

More information

EasyTronic III MANUAL SERVICE

EasyTronic III MANUAL SERVICE rev.6 EasyTronic III MANUAL SERVICE General characteristics: Power supply 24 Vac ±15% Max consumption at 24Vac 300mA Relay outputs 6 Maximum relay current 8 A res. Serial standard RS232 2 Serial standard

More information

EVF815 Installer manual ver. 2.0 Code 144F815E204 EVF815

EVF815 Installer manual ver. 2.0 Code 144F815E204 EVF815 EVF815 Split execution controller for temperature-controlled blast chillers (with capacitive touch-key user interface, which can be integrated into the unit) ENGLISH INSTALLER MANUAL ver. 2.0 CODE 144F815E204

More information

DIGITAL TEMPERATURE RELAY TR-100

DIGITAL TEMPERATURE RELAY TR-100 LTD Research-and-Manufacture Company DIGITAL TEMPERATURE RELAY USER S MANUAL www.novatek-electro.com - 2 - Service manual is intended for getting acquaints with hardware, operation principals, modes of

More information

EXD-SH1/2 Controller for EX/FX/CX with ModBus Communication Capability

EXD-SH1/2 Controller for EX/FX/CX with ModBus Communication Capability EXD-SH1/2 Controller for EX/FX/CX with ModBus Communication Capability Technical Bulletin EXD-SH1/2 are stand-alone universal superheat and or temperature controllers for air conditioning units or refrigeration

More information

EXD-SH1/2 Controller for EX/FX/CX with ModBus Communication Capability

EXD-SH1/2 Controller for EX/FX/CX with ModBus Communication Capability EXD-SH1/2 Controller for EX/FX/CX with ModBus Communication Capability Technical Bulletin EXD-SH1/2 are stand-alone universal superheat and or temperature controllers for air conditioning units or refrigeration

More information

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack Master Catalog 125 Temperature Controls Section A Product/Technical Bulletin Issue Date 1098 MR4PMUHV Electronic Temperature/Defrost Control with Relay Pack The MR series temperature controls are designed

More information

JDDT1 - Single Stage Digital Thermostat

JDDT1 - Single Stage Digital Thermostat JDDT1 - Single Stage Digital Thermostat CAUTION NOTICE: The thermostat must be installed by authorized professionals. It should be located in a place free of vibrations, impacts, and corrosive gases. SET

More information

OPERATION AND MAINTENANCE MANUAL

OPERATION AND MAINTENANCE MANUAL OPERATION AND MAINTENANCE MANUAL Prg Sel line alarm on on/off alarm enter Clear EMIpro MICROPROCESSOR CONTENTS 1 GENERAL CHARACTERISTICS Page 2 1.1 General description Page 2 2 EMIPRO USER INTERFACE Page

More information

ER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller

ER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller PB_ER65-DRW_ 202 ER65-DRW Controller Heating Applications Product Bulletin The controller is a digital device for domestic or residential heating units. It covers water and air heating applications. All-in-one

More information

IN NOURISHING SECURITY.

IN NOURISHING SECURITY. HOJA TÉCNICA 1400H171 Edición 02 (01 de 08) Electronic controllers for refrigeration R NEW leads the way Furthermore to control the CCPs Critical Control Points, in the HACCP Hazard Analysis Critical Control

More information

SERVICE & SETUP MANUAL WATER HEATER ELECTRONIC CONTROLLER

SERVICE & SETUP MANUAL WATER HEATER ELECTRONIC CONTROLLER SERVICE & SETUP MANUAL WATER HEATER ELECTRONIC CONTROLLER PVI INDUSTRIES, LLC - Fort Worth, Texas 76111 - Web www.pvi.com - Phone 1-800-433-5654 Page 1/ 24 PV500-41 03/17 INDEX 1. TECHNICAL DATA 3 2. WIRING

More information

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev. TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL Microener- Copyright 2010 FW 2.1 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection

More information

Ver.04 IP 65 FRONT. Serial programming. Protection level FAST FREEZING (ON/OFF) ECONOMIC SETPOINT(ON/OFF) DEFROST (ON/OFF) FUNCTIONS LOCKDOWN

Ver.04 IP 65 FRONT. Serial programming. Protection level FAST FREEZING (ON/OFF) ECONOMIC SETPOINT(ON/OFF) DEFROST (ON/OFF) FUNCTIONS LOCKDOWN evolution TC e POWER Fast Freezing DIGITAL CONTROLLER FOR REFRIGERATION AND OST Functions lockdown Control functions shutdown Serial programming IP FRONT Ver. Protection level TC e POWER TCEPWRT. DESCRIPTION

More information

Sf2+HF2 Sf2 Sf1 + Hf1 Sf1. 1 ON Fan1 enabled (only for XC30CX) 2 ON Fans enabled (only for XC30CX) kpa. Time

Sf2+HF2 Sf2 Sf1 + Hf1 Sf1. 1 ON Fan1 enabled (only for XC30CX) 2 ON Fans enabled (only for XC30CX) kpa. Time Digital controller for CDU management XC10CX and XC30CX 1. GENERAL WARNING... 1 2. GENERAL DESCRIPTION... 1 3. CONTROLLING LOADS... 1 4. FRONT PANEL COMMANDS... 1 5. OTHER FUNCTIONS... 1 6. MAIN INTERFACE...

More information

CAREL IR33+ CONTROLLER

CAREL IR33+ CONTROLLER CAREL IR33+ CONTROLLER Programming Instructions The Carel IR33+ controller has a two-level menu system for programming the operation of the case; Level 1 and Level 2 program settings. Unlike IR33, the

More information

XC10CX and XC30CX. Digital controller for CDU management 1. GENERAL WARNING 4. FRONT PANEL COMMANDS 2. GENERAL DESCRIPTION

XC10CX and XC30CX. Digital controller for CDU management 1. GENERAL WARNING 4. FRONT PANEL COMMANDS 2. GENERAL DESCRIPTION Digital controller for CDU management XC10CX and XC30CX 1. GENERAL WARNING... 1 2. GENERAL DESCRIPTION... 1 3. CONTROLLING LOADS... 1 4. FRONT PANEL COMMANDS... 1 5. OTHER FUNCTIONS... 1 6. MAIN INTERFACE...

More information

User Manual Ichill 200 L/D (Firmware version 1.7)

User Manual Ichill 200 L/D (Firmware version 1.7) User Manual Ichill 2 L/D (Firmware version 1.7) Pag. 1 of 142 INDEX 1. GENERAL FEATURES...8 1.1 Main Function... 8 2. ICHILL 2L/D TABLE OF THE FEATURES...1 3. USER INTERFACE...11 4. REMOTE KEYBOARD...15

More information

ERC2 Control Instructions

ERC2 Control Instructions Programg ERC2 Control Instructions The ERC 2 control initially powers up displaying 12: AM otherwise it will show the last configured selection (time or temperature). If a power outage occurs during normal

More information

Installer Manual KNX Touchscreen Thermostat

Installer Manual KNX Touchscreen Thermostat Installer Manual 02952 KNX Touchscreen Thermostat Index GENERAL FEATURES AND FUNCTIONALITY from page 5 ETS PARAMETERS AND COMMUNICATION OBJECTS from page 7 COMMUNICATION OBJECTS GENERAL FEATURES AND FUNCTIONALITY

More information

Follett Performance Plus

Follett Performance Plus Follett Performance Plus touchscreen user guide The next level of control in undercounter refrigeration Controller Operation - Performance Plus touchscreen Use and care of the LCD Performance Plus touchscreen

More information

XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring 1. GENERAL DESCRIPTION Model XWA11V-KIT, 100x64 mm format, is a microprocessor based light and alarm management controller,

More information

Temperature and moisture controller for cold rooms

Temperature and moisture controller for cold rooms GB AKO-6624 Temperature and moisture controller for cold rooms User Manual Page Index Warnings...3 Wiring...3 Maintenance...3 Description...4 Installation...6 Initial configuration...7 Operation...9 Configuration...22

More information

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

Modular Standard HP Chiller 1/4 screw compressor with Carel driver Program for pco¹ pco 2 and pcoc Modular Standard HP Chiller 1/4 screw compressor with Carel driver Manual version 1.0 25 September 2003 Program code: FLSTDmMSDE Do we want you to save you time and money?

More information

IP 65 FRONT. Serial programming. Protection level FAST FREEZING (ON/OFF) TC-900e POWER ECONOMIC SETPOINT(ON/OFF) DEFROST (ON/OFF) FUNCTIONS LOCKDOWN

IP 65 FRONT. Serial programming. Protection level FAST FREEZING (ON/OFF) TC-900e POWER ECONOMIC SETPOINT(ON/OFF) DEFROST (ON/OFF) FUNCTIONS LOCKDOWN evolution TCe POWER Ver. Fast Freezing DIGITAL CONTROLLER FOR REFRIGERATION AND OST Functions lockdown Control functions shutdown Serial programming IP 6 FRONT Protection level TCe POWER E TCEPWRT. DESCRIPTION

More information

ENERGY 200 Electronic Control for mono & bi- Compressor CHILLERS. User Manual

ENERGY 200 Electronic Control for mono & bi- Compressor CHILLERS. User Manual Electronic Control for mono & bi- Compressor CHILLERS User Manual 2/55 1 CONTENTS 1 Contents...3 2 How to use this manual...5 3 Introduction...6 3.1 Components...6 3.1.1 Basic module...6 3.1.2 Keyboards...6

More information

REMOTE CONTROL FOR CHILLER MYCHILLER

REMOTE CONTROL FOR CHILLER MYCHILLER REMOTE CONTROL FOR CHILLER MYCHILLER GENERAL FEATURES... 3 MAIN FUNCTIONS AND EQUIPMENT:... 3 LCD DISPLAY... 4 KEYBOARD... 5 BOARD CONFIGURATION... 7 LIST OF MAIN PARAMETERS... 7 CONFIGURATION OF MAIN

More information

XWA11V. Walk-In Temp / Door /Alarm / Light Module

XWA11V. Walk-In Temp / Door /Alarm / Light Module XWA11V Walk-In Temp / Door /Alarm / Light Module 1. GENERAL DESCRIPTION Model XWA11V, 100x64 mm format, is a microprocessor-based controller, suitable for temperature monitoring and alarming in a walk-in

More information

FX BLAST CHILLER ISO ISO 9001

FX BLAST CHILLER ISO ISO 9001 FX BLAST CHILLER ISO 14001 ISO 9001 Contents Environmental Management Policy 1 Disposal Requirements 1 Cabinet description 2 Controller Description Controller Operation 2 to 3 Alarms & Warnings 4 Parameter

More information

MasterCase. User Manual

MasterCase. User Manual MasterCase User Manual PRELIMINARY VERSION 24 January 2003 CONTENTS 1. Introduction...5 1.1 Main characteristics of the MasterCase...5 2. Layout of the hardware...7 2.1 Meaning of the inputs and outputs...7

More information

FlameGard 5 MSIR HART

FlameGard 5 MSIR HART FlameGard 5 MSIR HART Multi-Spectral Infrared Flame Detector HART Communication with the FlameGard 5 Multi-spectral Infrared Detector The information and technical data disclosed in this document may be

More information

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB Summary 1 CONNECTIONS... 3 1.1 TEMPERATURE PROBES...3 1.2 LOW VOLTAGE DIGITAL INPUTS...3 1.3 LIVE DIGITAL INPUTS...4 1.4 RELAY OUTPUTS...5 2 POWER SUPPLY... 6 3 SERIAL CONNECTIONS... 6 4 SOFTWARE... 7

More information

Operating Instructions XWA11V XWA11V. Walk-In Temp / Door /Alarm / Light Module

Operating Instructions XWA11V XWA11V. Walk-In Temp / Door /Alarm / Light Module XWA11V Walk-In Temp / Door /Alarm / Light Module 1. GENERAL DESCRIPTION Model XWA11V, 100x64 mm format, is a microprocessor-based controller, suitable for temperature monitoring and alarming in a walk-in

More information

FRUIT RIPENING CONTROLLER USER MANUAL SZ-FR INDIA

FRUIT RIPENING CONTROLLER USER MANUAL SZ-FR INDIA FRUIT RIPENING CONTROLLER USER MANUAL INDIA www.subzero.co Introduction Get to Know Your Controller The is a panel/wall mounted controller dedicated to control fruit ripening process. Features: Key Introduction

More information

Smart Temp. ApolloP/n Installation Manual. Version 1.0

Smart Temp. ApolloP/n Installation Manual. Version 1.0 Smart Temp ApolloP/n 44-800 Installation Manual Version 1.0 TABLE OF CONTENTS Introduction...6 Getting started...7 Installing the thermostat...8 Disassembly...8 Thermostat location...8 Mounting the subbase...8,

More information

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL WATER HEATER ELECTRONIC CONTROLLER USER MANUAL UPPER LED READOUT LED ICONS LOWER LED READOUT PVI INDUSTRIES, LLC - Fort Worth, Texas 76111 - Web www.pvi.com - Phone 1-800-433-5654 Page 1 / 7 PV500-40 03/17

More information

CAL EDT2412 TEMPERATURE CONTROLLER

CAL EDT2412 TEMPERATURE CONTROLLER Distributed by: M&M ntrol Service, Inc. www.mmcontrol.com/cal-controls.php 8-876-36 847-356-566 Please read this document carefully before using this product. The guarantee will be invalidated if the device

More information

IP 65 FRONT. Serial programming. Protection level FAST FREEZING (ON/OFF) TC-900e POWER ECONOMIC SETPOINT(ON/OFF) DEFROST (ON/OFF) FUNCTIONS LOCKDOWN

IP 65 FRONT. Serial programming. Protection level FAST FREEZING (ON/OFF) TC-900e POWER ECONOMIC SETPOINT(ON/OFF) DEFROST (ON/OFF) FUNCTIONS LOCKDOWN ONENT evolution Have this manual in the palm of your hand by FG Finder application. TCe POWER Ver. Fast Freezing DIGITAL CONTROLLER FOR REFRIGERATION AND OST Functions lockdown Control functions shutdown

More information

Operating Instructions XWA11V. XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

Operating Instructions XWA11V. XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring 1. GENERAL DESCRIPTION Model XWA11V-KIT, 100x64 mm format, is a microprocessor based light and alarm management controller,

More information

M2500 Engine Controller Installation Manual

M2500 Engine Controller Installation Manual M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...

More information

Energy XT PRO BaseLine Application [A00003xx-A00013xx]

Energy XT PRO BaseLine Application [A00003xx-A00013xx] Energy XT PRO BaseLine Application [A00003xx-A00013xx] 1/71 SUMMARY 1 How to use this manual... 4 Compressor type... 4 2 System configuration... 6 Compressor type... 6 3 Functions... 8 3.1 Temperature

More information

Sf2+HF2 Sf2 Sf1 + Hf1 Sf1. DLT Prb. Ground

Sf2+HF2 Sf2 Sf1 + Hf1 Sf1. DLT Prb. Ground Digital controller for CDU management XC30CX 1. GENERAL WARNING 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the instrument for easy and quick reference.

More information

Digital regulator for refrigeration and defrosting, 3 relays.

Digital regulator for refrigeration and defrosting, 3 relays. Installation guide ERC 213 Digital regulator for refrigeration and defrosting, 3 relays. 520H11062 The ERC 213 is a smart, multipurpose refrigeration controller with temperature and defrost management,

More information

MR3CCUHV Temperature/Defrost Control

MR3CCUHV Temperature/Defrost Control Master Catalog 125 Temperature Controls Section A Product/Technical Bulletin Issue Date 0401 MR3CCUHV Temperature/Defrost Control The MR3CCUHV Temperature/Defrost Control is designed to control the temperature

More information

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack Product/Technical MS4PMUHVT Issue Date 09/30/02 MS4PMUHVT Multi-Stage Electronic Control with Relay Pack The MS4PMUHVT Multi-Stage Electronic Control is intended for multi-stage temperature control applications.

More information

Comfort System T-21-P Touchscreen Thermostat Installation Manual

Comfort System T-21-P Touchscreen Thermostat Installation Manual Comfort System T-21-P Touchscreen Thermostat Installation Manual Version 1.40 INTRODUCTION The Comfort System T-21-P is a feature-rich touchscreen thermostat that can be battery powered or hardwired to

More information

Multi-Gas-Controller MGC2

Multi-Gas-Controller MGC2 Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants

More information

TMEF Series. SKOPE Vertical Freezer. User Manual

TMEF Series. SKOPE Vertical Freezer. User Manual TMEF Series SKOPE Vertical Freezer MAN10132 Rev. 1.0 Oct. 2010 TMEF Series SKOPE Vertical Freezer Type: (CAREL ir32 Controller) MAN10132 Rev. 1.0 Oct. 2010 2010 SKOPE Industries Limited. All rights reserved.

More information

SERVICE MANUAL REFRIGERATED AIR DRYER DIGI-PRO CONTROLLER WARRANTY NOTICE

SERVICE MANUAL REFRIGERATED AIR DRYER DIGI-PRO CONTROLLER WARRANTY NOTICE REFRIGERATED AIR DRYER SERVICE MANUAL DIGI-PRO CONTROLLER WARRANTY NOTICE Failure to follow the instructions and procedures in this manual or misuse of this equipment will VOID any warranty. 1. USER INTERFACE

More information

User Guide ems25plus. Page 1. Normal operation. Product interface

User Guide ems25plus. Page 1. Normal operation. Product interface Page 1 Product interface rmal operation During normal operation, EMS controllers display the information below. Assuming the product temperature is correct when the outlet is open, this means that the

More information

EM300(LX) electronic digital indicator. Alarm (IF PRESENT) ON for active alarm; blinking for silenced alarm that is still present

EM300(LX) electronic digital indicator. Alarm (IF PRESENT) ON for active alarm; blinking for silenced alarm that is still present EM3(LX) GB code 9IS4349 rel. 66 electronic digital indicator USER INTERFACE The user has a display and four buttons for controlling instrument status and programming. BUTTONS AND MENUS ACCESSING UP Button

More information

VTI MODEL itc5000 HEAT TRACING CONTROL SYSTEM OPERATIONS MANUAL

VTI MODEL itc5000 HEAT TRACING CONTROL SYSTEM OPERATIONS MANUAL VTI MODEL itc5000 HEAT TRACING CONTROL SYSTEM OPERATIONS MANUAL 1 Operations Manual for the VTI Model itc5000 Heat Tracing Control System Description The VTI Model itc5000 Heat Tracing Control System consists

More information

EWCM 900/S rel. 5/2000 ing

EWCM 900/S rel. 5/2000 ing cod. 9IS40178 EWCM 900/S rel. 5/2000 ing compressors and fans manager WHAT IT IS The EWCM 900(/S) is a series of controllers designed specifically for the control of a machine room in a refrigeration system.

More information

ER65 - Mini Rack Controller Electronic Refrigeration Line

ER65 - Mini Rack Controller Electronic Refrigeration Line PB_ER65_ 00 ER65 - Mini Rack Controller Electronic Refrigeration Line Device is a multi-stage digital controller. It is typically applied to small refrigeration rack units piloting compressors or condenser

More information

POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS

POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS products index 2 expert nano 06 plus200 EXPERT DATALOGGER 24 ecp_ base4 u vd 40 PEV pulse 60 expert nano 200 NANO 1CF 08 Plus300 EXPERT

More information

TRAULSEN TECHNICAL BULLETIN

TRAULSEN TECHNICAL BULLETIN TRAULSEN TECHNICAL BULLETIN PRODUCT SERVICE DEPARTMENT FORT WORTH, TX 76106 G-SERIES CONTROL RELEASE 2017 Introduction: This technical bulletin is intended to aid the field in using the G series control

More information

Manual For Panel Air Conditioner. Table of Contents

Manual For Panel Air Conditioner. Table of Contents Manual For Panel Air Conditioner Table of Contents 1 Upon Arrival A. Unpacking and Inspection B. Handling C. How to identify your Closed Loop Air Conditioner Installing your Air Conditioner 3 How it works

More information

WH7016E Thermostat Product Manual

WH7016E Thermostat Product Manual WH7016E Thermostat Product Manual Shenzhen Willhi Electronics Co., Ltd. Tel :0755-29539385 Fax :86-0755 -2953 9395 Technical support: Engineer Tian 1 Installation opening size: 2 Wiring diagram: 1 2 3L

More information

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control O M N I S T A T ELECTRONIC COMMUNICATING THERMOSTAT Installation Manual RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control Document Number 13I00-5 November, 1997 CONTENTS

More information

QUICK REFERENCE GUIDE SERIES IC100CX FW 1.8 (rel. 1.0)

QUICK REFERENCE GUIDE SERIES IC100CX FW 1.8 (rel. 1.0) QUICK REFERENCE GUIDE SERIES IC1CX FW 1.8 (rel. 1.) INDEX 1. General Advices 3 2. User Interface 4 3. Remote Keyboard VICX61 5 4. Display visualization 6 5. Silencing the Buzzer 6 6. First Installing

More information

REACH-IN SAFETEMP (-AAC)

REACH-IN SAFETEMP (-AAC) Slide 1 REACH-IN SAFETEMP (-AAC) FH1-AAC RH2-AAC-HD The Hoshizaki line of reach-ins consists of two types of refrigerators and freezers. The high end TEMPGUARD (-SSB) and the mid-range SAFETEMP ( AAC).

More information

ECH 985. Electronic controller for heat pumps used in residential hot water application

ECH 985. Electronic controller for heat pumps used in residential hot water application ECH 985 Electronic controller for heat pumps used in residential hot water application Introduction General Description ECH 985 is a heat pump for the following kinds of applications: water-water water-air

More information

REFRIGERATED ROOM & TEMPERATURE/HUMIDITY CONTROLLERS

REFRIGERATED ROOM & TEMPERATURE/HUMIDITY CONTROLLERS SECTION INDEX FUNCTIONS MODELS XLR100 COOL MATE - NT, MT AND LT APPLICATIONS - SERIAL OUTPUT Advanced multifunction controllers for NT refrigerated rooms XLR130 Advanced multifunction controllers for MT

More information

CONTROL PANEL INSTRUCTIONS RSQ-4

CONTROL PANEL INSTRUCTIONS RSQ-4 CONTROL PANEL INSTRUCTIONS RSQ-4 FOR SIRAC AIR TO WATER HEAT PUMP (SINGLE COMPRESSOR, AIR TO WATER) 1) System Configuration This system is composed of mainboard and wire control panel. 146mm Φ4 4 Mainboard

More information

EWHT800LX. Controllers for cold rooms and curing rooms for on-board installation

EWHT800LX. Controllers for cold rooms and curing rooms for on-board installation EWHT800LX Controllers for cold rooms and curing rooms for on-board installation INTRODUCTION The Coldface EWHT800LX series controls the temperature and humidity of a static or ventilated cold room. The

More information

TEMPERATURE CONTROLLER (STANDARD MODEL)

TEMPERATURE CONTROLLER (STANDARD MODEL) OPERATING MANUAL TEMPERATURE CONTROLLER (STANDARD MODEL) 689-0000 689-0005 Barnant Company 28W092 Commercial Avenue Barrington, Illinois U.S.A. 60010-2392 (847) 381-7050 (847) 381-7053 (Fax) 800-637-3739

More information

Controller for temperature control EKC 202D1

Controller for temperature control EKC 202D1 User Guide Controller for temperature control EKC 202D1 ADAP-KOOL Refrigeration control systems Introduction Application The controller is used for temperature control refrigeration appliances in supermarkets

More information

ST Wiring diagram. Product description. Standard temperature controller. Order number

ST Wiring diagram. Product description. Standard temperature controller. Order number ST64-31.10 Standard temperature controller Order number 900197.007 Old Id.Nr.: 386169 Wiring diagram Product description The controller ST64-31.10 was developed for simple thermostatic controls. The round

More information

XR60C ,QVWDOOLQJDQG2SHUDWLQJ,QVWUXFWLRQV. Digital controller with defrost and fans management 1. GENERAL WARNING 4. FRONT PANEL COMMANDS

XR60C ,QVWDOOLQJDQG2SHUDWLQJ,QVWUXFWLRQV. Digital controller with defrost and fans management 1. GENERAL WARNING 4. FRONT PANEL COMMANDS Digital controller with defrost and fans management XR60C CONTENTS 1. GENERAL WARNING 1 2. GENERAL DESCRIPTION 1 3. CONTROLLING LOADS 1 4. FRONT PANEL COMMANDS 1 5. TEMPERATURE ALARM AND ITS DURATION RECORDING

More information

TRUE TEMPERATURE CONTROLS SEQUENCE OF OPERATION

TRUE TEMPERATURE CONTROLS SEQUENCE OF OPERATION 28 Control version will vary with model and age of cabinet. LAE: t1 = Thermostat t2 = Defrost t3 = Display t3 probe is not installed and / or activated in all applications if t3 is not installed and /

More information

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays

More information

<IMG INFO> 339,95 195, ,35 14,15-1. ENERGY 400 Four Steps Chiller Heat Pump Controller

<IMG INFO> 339,95 195, ,35 14,15-1. ENERGY 400 Four Steps Chiller Heat Pump Controller 339,95 195,85 0 2 89,35 14,15-1 Four Steps Chiller Heat Pump Controller 1 CONTENTS 1 Contents...2 2 How to use this manual...4 3 Introduction...5 3.1 Components...5 3.1.1 Basic Module...5 3.1.2

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

Digital Controller XR70CX. Operating Manual. 5/10 Rev. B

Digital Controller XR70CX. Operating Manual. 5/10 Rev. B Digital Controller XR70CX Operating Manual 5/10 Rev. B 139734 Contents General Warnings 3 General Description 3 Regulation 3 Defrost 3 Fans 4 Front Panel Commands 4 Parameters 6 Installation and Mounting

More information

PROPlus Basic / CAMCtrl Basic

PROPlus Basic / CAMCtrl Basic 1564H502 Ed.05 GB PROPlus Basic / CAMCtrl Basic User Manual AKO-15645 AKO-15646 AKO-15648 AKO-15626 AKO-15627 Index 1.- Presentation...3 1.1.- Versions...3 1.2.- Maintenance...3 1.3.- Cautions...3 2.-

More information

dixel Installing and Operating Instructions PRELIMINAY

dixel Installing and Operating Instructions PRELIMINAY . GENERAL WARNING XW6K - AFV PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the instrument for easy and quick reference. The instrument shall not be used

More information

CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION

CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION PRODUCTS INDEX EXPERT NANO 1LT 06 PLUS200 EXPERT THR 34 EXPERT NANO 3CF 08 PLUS300 EXPERT U THR 36 EXPERT NANO 4CK 10 PLUS1000 THR 38 EXPERT NANO 2ZN

More information

Top Mount Full Length Swinging Doors

Top Mount Full Length Swinging Doors Top Mount Full Length Swinging Doors *Shown in FT103SD3 model Model FT77SD FT103SD3 FT138SD Width 77 103 138½ Depth 32 32 32 Height 86 ½ 86 ½ 86 ½ Volume/cu. Ft. 77 103 140 Doors 3 3 4 Door Size 23 x 66

More information

IPC108D - IPC108E (V.2.0)

IPC108D - IPC108E (V.2.0) IPC108D - IPC108E (V.2.0) APPLICATION GUIDE INDEX 1. IMPORTANT RECOMMENDATIONS 6 1.1 PRODUCT DISPOSAL (WEEE) 7 2. GENERALITIES 8 3. AVAILABLE APPLICATION CONFIGURATIONS 8 3.1 MAIN FUNCTIONS 9 4. SUPERVISION

More information

technical bulletin Control Link RSC Installation Instructions

technical bulletin Control Link RSC Installation Instructions COMPU TER PROCE SS CONTRO L S Overview The Control Link Refrigeration System Controller (CL-RSC) is an electronic device that can control all functions of a single-compressor refrigeration system, including

More information

Electronic Controls Handbook Programming Flow Charts & Parameter Lists for

Electronic Controls Handbook Programming Flow Charts & Parameter Lists for Electronic Controls Handbook Programming Flow Charts & Parameter Lists for EWPC Series Controllers A Specialists in electronic refrigeration control www.thermofrostcryo.co.uk London Tel. 020 8655 7600

More information

Installation and User Guide

Installation and User Guide Installation and User Guide User CTS 2 602 manual by Nilan VPM 360 Modbus Version: 2.00 08-05-2014 Software-version: 2.20 The following information describes how to connect to Nilan CTS 602 controls by

More information

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS HP727S Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS 1. General Description 2. Specifications 3. Installation Instructions 4. Electrical Wiring 5. Instrument Wiring

More information

Danfoss gas detection unit Type GD Heavy Duty

Danfoss gas detection unit Type GD Heavy Duty Data sheet Danfoss gas detection unit Type GD Heavy Duty The Heavy Duty gas detection units are used for monitoring and warning of hazardous Ammonia gas concentrations. They are intended for ATEX/ IECEx

More information