ER65 - Mini Rack Controller Electronic Refrigeration Line
|
|
- Jocelin Barrett
- 6 years ago
- Views:
Transcription
1 PB_ER65_ 00 ER65 - Mini Rack Controller Electronic Refrigeration Line Device is a multi-stage digital controller. It is typically applied to small refrigeration rack units piloting compressors or condenser fans It incorporates control loops that sequence on-off stages and can pilot a proportional device (i.e. fan speed driver). Controls are processed by temperature or pressure sensing the refrigerant variations Device is configurable and allows facing a large number of units within the limit of 4 stages. It includes additional features as alarm history page, run time counters for maintenance operations and communication capability to be connected to a monitoring system. Physical Features Robust front panel for durability and long term usage Removable plug connectors for quick mounting and wiring Direct 30V supply: no external transformer required Embedded RS485 (Modbus or N open): no additional communication card required Selectable input: pressure or temperature Application Features Controls: On-off and proportional Flexible sequencer including optimization (i.e. rotation) Maintenance: run time counters, alarm history, Sensor monitoring: minimum and maximum peaks
2 PB_ER65_ 00 Dimensions in mm
3 PB_ER65_ 00 3 Wirings 4 ALR 7()A DI3 DI4 DI5 L N 8 7 OUTPUTS 5()A PWM V IN V P -T DI DI POWER Communication wirings N OPEN MODBUS CABLE ACCESSORY Rt Rt - Com Rt Rt - 50 cm Rt (blue) 4 - Rt- (white) 7 - Com (black) ER-COM-
4 4 PB_ER65_ 00 Functions Device Features Description Direct Power Supply Devices are powered directly with 30 VAC RS485 Communication Port Keyboard Lock RS485 communication port supports N open or Modbus protocols (see product ordering codes). Port is used for commissioning operations and integration to monitoring systems Display can be locked in order to prevent user to change parameter settings. When locked, only user information is available Pressure or Temperature Control Pressure or temperature inputs can be alternatively selected as control process variable Sequencer Device includes several strategies to sequence the outputs, from fixed sequence to optimization options like rotation or load manager OUT 4 stages relays Device manages to 4 compressors or fans OUT Auxiliary Relays Dedicated relays is available to manage alarm reporting OUT Analogue Output PWM output is also available to pilot speed driver IN Multifunction Inputs (DI to DI5) Monitoring (Min/Max) Configurable digital inputs are available to manage remote contacts such generic alarm, standby or nd setpoint or circuit alarms such high pressure, low pressure, oil or liquid alarms Device monitors periodically the current sensor value and memorizes the minimum and maximum peaks. Peaks values are visualized on display info menu Control Features Dead Band Control Sequence strategy PI control Alarm Management Description See detailed description hereafter
5 PB_ER65_ 00 5 Process Variable Control process variable can be selected between temperature and pressure. Display shows both pressure and temperature by applying refrigerant conversion curves. Dead Band Control Control is based on a neutral zone where control action is frozen. Control is activated again if the process variable moves outside this band. Outputs are started if the process variable moves above the dead band. Outputs are stopped if the process variable moves below the dead band. Two separated parameters define the dead band zone around the setpoint. It is then possible to have different start and stop action. Process Variable Start Zone Upper Dead band Neutral Zone - Lower Dead band Time Stop Zone
6 6 PB_ER65_ 00 5 is blocked between minimum and maximum values to limit user setpoint adjustment. A second setpoint can be defined to save energy during night or reduced load periods. Periods are defined manually from display/network or from external digital input command. limits Maximum setpoint Alternative Selection (option) Normal setpoint Alternative Minimum setpoint or IN Output Timers Start Up timer Timer is applied at device power up. All outputs are delayed. It allows preheating the compressor crankcase before any control operations. Process Variable Control Enable Time Start-Stop timers Power up Timers are applied between the outputs. It prevents from activating or deactivating next output if not required. Process Variable Time Start Delay Stop Delay Output Output
7 PB_ER65_ 00 7 Output Sequencer Control sequence manages up to 4 outputs. Output Capacity Each ouput is associated with a capacity expressed in % of the total power equipment load. Capacity parameter (OCx on the display) is set to 0 if the output is not used. Example: Compressor - 5kW Capacity = 50% Compressor - 5kW Capacity = 50% Sequence Strategy Sequential: outputs are sequentially activated according to a fixed order (First In Last Out). PV 4 3 SEQUENTIAL 4 3 Rotation: outputs are sequentially activated but the ordering depends on the running time of each output. It is particularly suitable for outputs with same capacity. PV 3 4 ROTATION 4 3 Load optimization: the sequencer selects the number of outputs according to the requested load. It is suitable when outputs have different capacities PV LOAD OPTIMIZATION
8 8 PB_ER65_ 00 Sequence Setting Examples Example : compressors with rotation strategy Setup Table Parameter Value Compressor OC 33% Compressor OC 33% Compressor 3 OC3 33% Sequencer CM ROT Example : compressors with different capacities Setup Table Parameter Value Compressor OC 50% Compressor OC 5% Compressor 3 OC3 5% Sequencer CM PO Example 3: semi-hermetic compressor with one stage (normally closed valve) Setup Table Parameter Value Compressor OC 00% Stage OC - Sequencer CM SEN Example 4: semi-hermetic compressor with two stages (normally opened valves) Setup Table Parameter Value Compressor OC 00% Stage OC - Stage OC3 - Sequencer CM SEN Example 5: condensing unit Setup Table Parameter Value Fan OC 5% Fan OC 5% Fan 3 OC3 5% Fan 4 OC4 5% Sequencer CM SEN
9 PB_ER65_ 00 9 Analog Control Proportional-Integral (PI) control loop can be activated to pilot an analogue output (PWM). It is particularly applied to pilot unit with fan speed driver. Analogue Output 0% Proportional band Process Variable Time Counter A counter is associated to each output. Running hours are memorized by the device and visualized from the display. A threshold value can be set in order to produce an alarm for maintenance operation. Process Variable Time Stage Status Standby mode Unit can be fully stopped by standby commands available on display front panel or wired remote switch.
10 0 PB_ER65_ 00 Alarm Management Table sums up all the alarms managed by the devices Name Input Output High alarm Sensor No action on control - Alarm output activated Low Alarm Sensor No action on control - Alarm output activated General alarm Digital input All control outputs off - Alarm output activated High pressure Digital input Specific action (see parameters DxA) - Alarm output activated Low pressure Digital input Specific action (see parameters DxA) - Alarm output activated Oil pressure Digital Input Specific action (see parameters DxA) - Alarm output activated Liquid pressure Digital Input Specific action (see parameters DxA) - Alarm output activated Maintenance Digital Input No action on control - Alarm output activated Sensor Failure Sensor All control outputs off - Alarm output activated Sensor alarm Alarm is detected if control sensor moves outside low and high thresholds. Alarm activation could be delayed in order to consider temporary fluctuations due to specific operations such start up. Thresholds are independent from the setpoint (absolute alarm). Alarm situation is ending when temperature turns back between low and high thresholds. Process Variable High Limit Low Limit Alarm status On Off Time Alarm Outputs Alarms are reported on display front panel LED, internal buzzer or auxiliary output. Alarm is reset automatically or manually. Acknowledge action from display front panel is necessary if manual reset has been selected. Alarm Activation Manual reset Display alarm LED Internal Buzzer (option) OUT Auxiliary Relays Alarm History Device is able to memorize last 0 alarms. History is available on alarm display page.
11 PB_ER65_ 00 Alarm LED Bar Pressure LED: on when pressure value is displayed C Temperature LED: on when temperature value is displayed % Ouput load LED: on when load is displayed Display layout h or x000 Output counter indication LED LED ON when counter in hour is displayed LED BLINKS when counter in x000 hours is displayed Display Menus a). Home a). Home b.) SETPOINT >5 b.) STANDBY >5 c.) CONFIGURATION c.) ALARM MUTE/RESET d.) INFO Function Keys e.) ALARM HISTORY Menus Navigation f.) Escape * * Automatic ESCAPE after 30 sec.... Counter/Min/Max Reset Setting 5 Parameters Setting
12 PB_ER65_ 00 Info Menu Code Description OUTx Status of the outputs with run time counter values x= to 4 SP ASP Alternative (if applicable) IHI Monitored highest peak, sensed on the control sensor ILO Monitored lowest peak, sensed on the control sensor LOC Keyboard lock parameter Status Counter (hours) Messages and Error Codes Code Description Action OR Control sensor failure To check sensor wiring or to replace it HP High pressure alarm To check refrigerant circuit LP Low pressure alarm To check refrigerant circuit OIL Oil pressure/level alarm To check refrigerant circuit LL Liquid level alarm To check refrigerant circuit ALR General alarm To check plant MTN Maintenance alarm To plan maintenance operations OFF Standby To restart unit with keyboard or Digital Input HI LO High alarm Low alarm To check plant (abnormal control sensor deviation) Counter (x000 hours) Output Visualization Menu Code SP ASP Description Alternative (if applicable) 3 csp: ASP: Alternative setpoint Manual Selection Alarm History Menu Code SP ASP Description Alternative (if applicable)
13 PB_ER65_ 00 3 Configuration Menu Code Default Range Description Sensor Management INP -P -P / -T Control sensor selector: -P: pressure sensor selected -T:temperature sensor selected MPI 4mA 0mA, 4mA Pressure sensor type: 0mA: 0-0 ma type 4mA: 4-0 ma type RLO - - to RHI bar Pressure sensor low range RHI 45 RLO to 45 bar Pressure sensor high range OS 0 - / bar or C Control sensor offset REF 404, 507,, 34 Refrigerant type: R404a, R507, R, R34a Settings SPL / SPH Low Limit SPH 35 SPL / 0 C High Limit CSP 3.5 SPL to SPH ASM NON NON, MAN, DI Alternative setpoint selector: NON: not used MAN: manual (display/network) DI: digital input ASP 5 SPL to SPH Alternative setpoint Control Settings DBL - -0 / 0 bar or C Output control: lower dead band DBH 0 / 0 bar or C Output control: upper dead band LON 0 0 / 50 sec Output control: inter-stage on delays LOF 0 0 / 50 sec Output control: inter-stage off delays SON 5 0 / 50 sec Output control: internal stage on delays SOF 5 0 / 50 sec Output control: internal stage off delays PB 0 0 / 0 bar or C Analogue control: proportional band IT 0 0 / 50 sec Analogue control: integral time DxM NON Digital Input Settings (x= to ) NON, SBY, ASP, ALR DxC CLS OPN, CLS DxM NON Digital input selector NON = Not used SBY = standby ASP = alternative setpoin ALR = generic alarm (interlock) Digital input polarity OPN= contact active on opening CLS= contact active on closing Digital Input Settings (x= 3 to 5) NON, HP, LP, OIL, LL, ALR DxC CLS OPN, CLS DxD 5 0 /0 min Alarm delay DxA DSP DSP, SAR, SMr Digital input selector Non = Not used HP = high pressure alarm LP = low pressure alarm OIL= oil low pressure alarm LL= liquid low alarm ALR= generic alarm Digital input polarity OPN= contact active on opening CLS= contact active on closing Alarm function DSP: only alarm displaying SAR: scaling down (see SCD parameter) automatic reset alarm SMR: interlock, manual reset alarm Other Settings MTC 0 0 / 600 (x00 hours) Maintenance threshold alarm SB YES NO, YES Standby key enable TLD 5 / 30 min Monitoring period SND NO NO, YES Alarm buzzer enable ADR / 55 Network address CM SEN ROT, SEN, PO OCx 5 - / 00 % Output Settings (x= to 4) Sequence strategy: ROT: rotation SEN: sequential (FILO) PO: load optimization 0-00: output load -= output used as normally closed stage -= output used as normally opened stage MLS 3 0 / 30 min Minimum off time LRT 60 0 / 0 min Rotation enable time DPU 0 / 0 min Start up delay SCD 40 0 / 00 % Scaling down: maximum output capacity on alarm Threshold Alarm Settings ALA (RLO) / AHA bar or C Alarm low threshold AHA 35 ALA / 0 (RHI) bar or C Alarm high threshold AID 30 0 /0 min Alarm delay
14 4 PB_ER65_Preliminary Ordering Codes All ordering codes are relative to individual product package. All items are also available with bulk pack (i.e. quantity of 0 controllers). Please refer to JC customer service. Controllers ER65-DR30-00C Controller, DIN Rail mount, NOpen, removable plug connectors ER65-DR30-50C Controller, DIN Rail mount, MODBUS, removable plug connectors Accessories & Spare parts ER-NTC-0C NTC Sensor, m, universal replacement T T ER-NTC-C ER-NTC-C NTC Sensor, m, T replacement NTC Sensor, m, T replacement T T ER-COM-C RS485 cable,.5 m, RJ connector, 8 wires ER-TER-3C Spare parts, removable plug connectors kit Technical Specification Product Codes Power Requirements ER65-DR30-xxC 30 VAC/VDC ±0%, 50/60 hz, 3 W Protection Class Ambient Operating Conditions IP0 Range -40 to 0 C -0 C to 50 C 5 to 80% RH (non-condensing) Accuracy Sensor /- K NTC, P499 Relay Outputs see figure Dimensions see figure Compliance Johnson Controls, Inc., declares that these products are in compliance with the essential requirements and other relevant provisions of the EMC Directive 004/08/EC and Low Voltage Directive 006/95/EC. Building Efficiency Headquarters: Milwaukee, Wisconsin, USA Branch Officies: Principal Cities World-wide Metasys and Johnson Controls are registered trademarks of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. 00 Johnson Controls, Inc. Published in Europe
ER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller
PB_ER65-DRW_ 202 ER65-DRW Controller Heating Applications Product Bulletin The controller is a digital device for domestic or residential heating units. It covers water and air heating applications. All-in-one
More informationER52 - Evaporator Controller
ER52 - Evaporator Controller Electronic Refrigeration Line Product Bulletin Devices are standalone digital controller for static or ventilated refrigeration units working at positive temperatures. They
More informationTM-3100 Series Room Temperature Sensor
PB_TM-3100_12 2009 TM-3100 Series Room Temperature Sensor The Johnson Controls TM-3100 Series Room Temperature Sensor provide passive sensing of temperature in HVAC application. The TM-3100 is equipped
More informationXC1008D -XC1011D- XC1015D and VGC810
Electronic Controller for Compressor Racks XC1008D -XC1011D- XC1015D and VGC810 Instructions Manual INDEX 1. GENERAL WARNING 4 1.1 PLEASE READ BEFORE USING THIS MANUAL 4 1.2 SAFETY PRECAUTIONS 4 2. WIRING
More informationVERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER
1 VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1. INTRODUCTION This manual contains information for the installation and operation and tuning of our Vertex VT10 series self-tuning
More informationARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER
ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER AI-208 (V7.6) User Manual I. Model Code Symbol The type of AI-208 is made up of 4 parts: AI-208 A G L2 Part 1 (Series) Part 2 (Size) Part 3 (Oupt) Part 4
More informationUser Manual Ichill 200 L/D (Firmware version 1.7)
User Manual Ichill 2 L/D (Firmware version 1.7) Pag. 1 of 142 INDEX 1. GENERAL FEATURES...8 1.1 Main Function... 8 2. ICHILL 2L/D TABLE OF THE FEATURES...1 3. USER INTERFACE...11 4. REMOTE KEYBOARD...15
More informationTemperature Controllers
Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65
More informationT125-E. Electric Fan Coil Thermostat. Product Bulletin. Operation. Appearance. Installation, Service and Maintenance
T125-E Electric Fan Coil Thermostat Product Bulletin New Generation T125 Electric Fan Coil Thermostats are designed to control heating, cooling, or air conditioning unit in Commercial, Industrial and Residential
More informationT60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability
T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability Product Bulletin T601DFH-4, T602DFH-4, T603DFH-4, T604DFH-4, T605DFH-4, T601DFH-4+PIR, T602DFH-4+PIR,
More informationEC3-X33 Stand-alone Superheat Controller Technical Data
Technical Data EC3-X33 is a stand-alone universal superheat controller for air conditioning, refrigeration and industrial applications such as chillers, industrial process cooling, rooftops, heat pumps,
More informationEC3-X33 Stand-alone Superheat Controller
is a stand-alone universal superheat controller for air conditioning, refrigeration and industrial applications such as chillers, industrial process cooling, rooftops, heat pumps, package unit, close control,
More informationTEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs
TEC2620 Series Non-Programmable Fan Coil Network Thermostat ler and Remote I/O Relay Packs TEC2620H-0, TEC2620C-0, TEC2620H-0+PIR, TEC2620C-0+PIR, TEC2621H-0, TEC2621C-0, TEC2621H-0+PIR, TEC2621C-0+PIR
More informationDanfoss gas detection units
Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning
More informationT6580 FAN COIL CONTROLLER
20 DESCRIPTION A pleasing and modern appearance makes the T6580 ideal for living quarter applications, in particular offices and hotels. In all versions, the control is Proportional + Integral (P+I). This
More informationInstaller Manual KNX Touchscreen Thermostat
Installer Manual 02952 KNX Touchscreen Thermostat Index GENERAL FEATURES AND FUNCTIONALITY from page 5 ETS PARAMETERS AND COMMUNICATION OBJECTS from page 7 COMMUNICATION OBJECTS GENERAL FEATURES AND FUNCTIONALITY
More informationCapacity controller EKC 331T REFRIGERATION AND AIR CONDITIONING. Manual
Capacity controller EKC 331T REFRIGERATION AND AIR CONDITIONING Manual Introduction Application The controller is used for capacity regulation of compressors or condensers in small refrigerating systems.
More informationTIREE FAN COIL CONTROLLER - T6580
TIREE FAN COIL CONTROLLER - T6580 PRODUCT SPECIFICATION SHEET 20 DESCRIPTION A pleasing and modern appearance makes the TIREE ideal for living quarter applications, in particular offices and hotels. In
More informationNA G µair CONNECT 2
NA 9.41 G 7-216 µair CONNECT 2 Control manual EN CONTENTS PAGE 1. GENERAL INFORMATION 2 2. COMPONENTS 3 2.1 On the front: 3 2.2 On the rear: 4 3. MENU TREE 7 4. ACCESS LEVEL (menu 8) 1 5. CONFIGURING
More informationModular Standard HP Chiller 1/4 screw compressor with Carel driver
Program for pco¹ pco 2 and pcoc Modular Standard HP Chiller 1/4 screw compressor with Carel driver Manual version 1.0 25 September 2003 Program code: FLSTDmMSDE Do we want you to save you time and money?
More informationThermometers and temperature controllers
D144H002 Ed.07 GB Thermometers and temperature controllers User Manual Contents AKO Electromecánica thanks and congratulates you for purchasing our product, in whose development and manufacture the most
More informationDIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)
Evco S.p.A. Code 104K204E05 page 1/5 EVK204 Digital controller for ventilated refrigerating units, with HACCP and Energy Saving functions version 1.05 GB ENGLISH 1 PREPARATIONS 1.1 Important Please read
More informationTwo-Channel Gas Controller
Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously
More informationCLEANROOM MONITOR CR3A Network - Installation Instructions
CLEANROOM MONITOR CR3A Network - Installation Instructions INTRODUCTION The CR3 Series Cleanroom Monitor, was developed specifically to allow for monitoring of confined spaces with accuracy and reliability.
More informationLift Station Level Controller
Lift Station Level Controller Installation and Operation Manual 1 California Motor Controls, Inc. Benicia, CA Table of Contents 1. Features Product Overview... 4-6 Access Security... 7 Optional Features...
More informationReplaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge
Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays
More informationTER Active Room Temperature Sensor (Controller),
Product sheet SN1.415 Type TER TER Active Room Temperature Sensors (Controllers) The TER active sensors are designed to detect temperature in the room spaces. The TER sensors have linear 0..10V signals
More informationEC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF:
EC 6-295P220S001 smart guide ON-OFF digital controller for ventilated refrigerating units Version 1.01 of 15 th March 2005 File ec6295p220s001_eng_v1.01.pdf PT EVCO S.r.l. Via Mezzaterra 6, 32036 Sedico
More information5-stage compressor racks + 2 converter outputs
GB 1454H502 Ed.02 AKO-14545 AKO-14545-C 5-stage compressor racks + 2 converter outputs User Manual Contents Page 1.- Precautions...3 2.- Versions and part numbers...3 3.- Description...3 3.1.- Keypad functions...3
More informationENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE
ENERGY LIGHT USER S GUIDE Release January 2001 CONTENTS 1.0 GENERAL CHARACTERISTICS... 4 1.1 MAIN CHARACTERIS TICS... 4 2.0 USER INTERFACE (CODE C5121230)... 5 2.1 DISPLAY... 5 2.2 MEANING OF THE LEDS...
More informationCapacity Controller AK-PC 351
User Guide Capacity Controller AK-PC 351 ADAP-KOOL Refrigeration Control System Introduction Application The controller is used for capacity regulation of compressors and condensers in small refrigeration
More informationSf2+HF2 Sf2 Sf1 + Hf1 Sf1. 1 ON Fan1 enabled (only for XC30CX) 2 ON Fans enabled (only for XC30CX) kpa. Time
Digital controller for CDU management XC10CX and XC30CX 1. GENERAL WARNING... 1 2. GENERAL DESCRIPTION... 1 3. CONTROLLING LOADS... 1 4. FRONT PANEL COMMANDS... 1 5. OTHER FUNCTIONS... 1 6. MAIN INTERFACE...
More informationCapacity controller AK-PC 651
User Guide Capacity controller AK-PC 651 ADAP-KOOL Refrigeration Control System Introduction Application The controller is used for capacity regulation of compressors and condensers in small refrigeration
More informationTC-9102 Applications
Application Note January 7, 2004 APPLICATION NOTE TC-9102 Applications Configuring TC-9102 Applications...3 Introduction... 3 Key Concepts... 4 TC-9102 Controller... 4 Control Modes...8 Procedure Overview...
More informationDigital regulator for refrigeration and defrosting, 3 relays.
Installation guide ERC 213 Digital regulator for refrigeration and defrosting, 3 relays. 520H11062 The ERC 213 is a smart, multipurpose refrigeration controller with temperature and defrost management,
More informationInstructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C
Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C 1. General The hand-held micro terminal is used for setting the motor parameters of the SILVER C. 2. Installation
More informationXC10CX and XC30CX. Digital controller for CDU management 1. GENERAL WARNING 4. FRONT PANEL COMMANDS 2. GENERAL DESCRIPTION
Digital controller for CDU management XC10CX and XC30CX 1. GENERAL WARNING... 1 2. GENERAL DESCRIPTION... 1 3. CONTROLLING LOADS... 1 4. FRONT PANEL COMMANDS... 1 5. OTHER FUNCTIONS... 1 6. MAIN INTERFACE...
More informationCONTROLS MANUAL. CARRIERrtc basic & medium electronic control 48/50 EN/EH 50 HB/HF/NZ/NF. Original document
CONTROLS MANUAL CARRIERrtc basic & medium electronic control 48/50 EN/EH 50 HB/HF/NZ/NF Original document Contents 1. General description....5 2. Set-up... 6 2.1. micropc control board... 6 2.2. TCO user
More informationOPERATION AND MAINTENANCE MANUAL
OPERATION AND MAINTENANCE MANUAL Prg Sel line alarm on on/off alarm enter Clear EMIpro MICROPROCESSOR CONTENTS 1 GENERAL CHARACTERISTICS Page 2 1.1 General description Page 2 2 EMIPRO USER INTERFACE Page
More informationREMOTE CONTROL FOR CHILLER MYCHILLER
REMOTE CONTROL FOR CHILLER MYCHILLER GENERAL FEATURES... 3 MAIN FUNCTIONS AND EQUIPMENT:... 3 LCD DISPLAY... 4 KEYBOARD... 5 BOARD CONFIGURATION... 7 LIST OF MAIN PARAMETERS... 7 CONFIGURATION OF MAIN
More informationModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.
ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page
More informationSeries Temperature Controller Instruction Sheet
Series Temperature Controller Instruction Sheet Thank you very much for purchasing DELTA A Series. Please read this instruction sheet before using your A series to ensure proper operation and please keep
More informationONX908PIT-V1-S1-F1/B Modulating Digital Thermostat
ONX908PIT-V1-S1-F1/B Modulating Digital Thermostat Installation and operation instructions The ONX908PIT-V1-S1-F1 modulating digital thermostats are designed to provide Proportional-Integral (PI) modulating
More informationC66. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C66. User's Guide. Installer's Guide. *vi7cc502* *087R8069* *087R8069* *vi7cc502*
User's Guide VI.7C.C5.02 2005.09 C66 *vi7cc502* *087R8069* www.danfoss.com ECL Comfort User's Guide ECL Comfort Installer's Guide www.danfoss.com *087R8069* *vi7cc502* Mixing controller with PI controlled
More informationACT2-CS Convenience Store Controller
Refrigeration Systems Technical Manual 804 Product Bulletins Section Product Bulletin Issue Date 0899 ACT2-CS Convenience Store Controller The ACT2-CS Convenience Store Controller is a fully programmable,
More informationLabel Displayed temperature Pb1 if the P4 parameter is set to 0, 1 or 2, room temperature if the P4 parameter is set to 3, incoming air temperature
EVCO S.p.A. EV3B24 Data sheet ver. 1.0 Code 1043B24E104 Page 1 of 6 PT 12/15 EV3B24 Basic controller for low temperature bottle coolers, cabinets, refrigerated cabinets, tables and pizza counters, with
More informationEC2-5x2 Series Condensing Unit Controllers
Technical Data The EC2-Series form a new generation of electronic controllers for refrigeration and air conditioning. The controllers combine in the small industry standard housing maximum functionality
More informationTable of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11
Table of Contents 1. OVERVIEW... 3 2. SYSTEM LAYOUT... 4 3. SPECIFICATIONS... 8 3.1 SYSTEM COMPONENTS...9 3.2 PLC INPUTS AND OUTPUTS...9 3.3 FUNCTION KEYS...10 3.4 DEFAULT SET POINTS AND TIMERS...10 4.
More informationSpecification , July 2015
Technical Information PrecisionLine Controllers EDC21 / EDC22 / EDC23 EASYSET DIGITAL CONTROLLERS Specification 51-52-3-48, July 215 Introduction The EDC21, EDC22 and EDC23 controllers provide precise
More informationCDR-AL Room CO 2 Traffic Light Alarm Units and Sensors
Product sheet SN1.402 Type CDR-AL CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors CDR-AL sensors are designed to detect carbon dioxide concentration and temperature in the room spaces. The units
More informationCorrigo E - User Manual Ventilation
Corrigo E - User Manual Ventilation DISCLAIMER The information in this manual has been carefully checked and is believed to be correct. Regin however, makes no warranties as regards the contents of this
More informationEpsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points
Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique
More informationOxygen (O2) Single-Point Gas Detection System
Oxygen (O) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in oxygen (O) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity
More informationTC515 and TC600 Installation Manual. a Winters company
THERMOLINE TEMPERATURE CONTROLLERS TC515 and TC600 Installation Manual a Winters company Guarantee 12 months Congratulations on the purchase of this new product. Special care with the design, workmanship
More informationTRUE TEMPERATURE CONTROLS SEQUENCE OF OPERATION
28 Control version will vary with model and age of cabinet. LAE: t1 = Thermostat t2 = Defrost t3 = Display t3 probe is not installed and / or activated in all applications if t3 is not installed and /
More informationController for Condensing unit Optyma Plus Evo 3 REFRIGERATION AND AIR CONDITIONING. Manual
Controller for Condensing unit Optyma Plus Evo 3 REFRIGERATION AND AIR CONDITIONING Manual Introduction Application Condensing unit control Advantages Condensing pressure control in relation to outside
More informationMODEL WIND TRACKER
MODEL 06201 WIND TRACKER NOVEMBER 2001 MANUAL PN: 06201-90 R. M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 MODEL 06201 WIND TRACKER
More informationMetasys Integrator Cleaver-Brooks Application
Metasys Connectivity Technical Manual 69. Metasys Integrator Section Application Note Issue Date 0900 APPLICATION NOTE Metasys Integrator Cleaver-Brooks Application lntroduction Page Application Details
More informationReciprocating Chiller
HVAC PRO for Windows User s Manual 637.5 OEM Section Technical Bulletin Issue Date 1094 Reciprocating Chiller Reciprocating Chiller Page 3 Description 3 Theory of Operation 5 Overview 5 Control Sequence
More informationSERVICE & SETUP MANUAL WATER HEATER ELECTRONIC CONTROLLER
SERVICE & SETUP MANUAL WATER HEATER ELECTRONIC CONTROLLER PVI INDUSTRIES, LLC - Fort Worth, Texas 76111 - Web www.pvi.com - Phone 1-800-433-5654 Page 1/ 24 PV500-41 03/17 INDEX 1. TECHNICAL DATA 3 2. WIRING
More informationC62. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C62. User's Guide. Installer's Guide *VIKME102* *087R8091* *087R8091* *VIKME102*
User's Guide VI.KM.E1.02 2005.09 C62 *VIKME102* *087R8091* www.danfoss.com ECL Comfort User's Guide ECL Comfort Installer's Guide www.danfoss.com *087R8091* *VIKME102* Double mixing controller C62 VI.KM.E1.02
More informationCapacity controller for water chiller AK-CH 650
Capacity controller for water chiller AK-CH 650 Menu operation via AKM Menu list This menu function can be used together with system software type AKM. The description is divided up into function groups
More informationSLV CONTROLLER 105N46XX SERIES
WITH MORE THAN 50 YEARS OF EXPERIENCE IN COMPRESSOR TECHNOLOGY AND HIGHLY COMMITTED EMPLOYEES, OUR FOCUS IS TO DEVELOP AND APPLY THE ADVANCED COMPRESSOR TECHNOLOGIES TO ACHIEVE STANDARD SETTING PERFORMANCE
More informationInstructions AK-PC 520
Instructions AK-PC 520 084B8012 Identification Dimensions 084B8012 Principle NZ control PI or P control RI8NM102 04-2009 ENGLISH Connections P0/Pc: AKS 32R: 1 = Black = + 2 = Blue = - 3 = Brown = s Brine
More informationService Manual. Chiller unit MQH R 410A. Release Date Rev Review Date november
Service Manual Chiller unit MQH R 410A Release Date Rev Review Date november 2008 ----- ----- MQH R410A ELECTRONIC CONTROL CONTROL PANEL The control panel allows the user to carry out all the operations
More informationMS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack
Product/Technical MS4PMUHVT Issue Date 09/30/02 MS4PMUHVT Multi-Stage Electronic Control with Relay Pack The MS4PMUHVT Multi-Stage Electronic Control is intended for multi-stage temperature control applications.
More informationTEC2100 Series Networked Thermostats
Product Bulletin Issue Date February 11, 2004 TEC2100 Series Networked Thermostats The TEC2100 Series of thermostats is a family of highly advanced thermostats specifically designed for control of equipment
More informationEKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual
EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING Manual Contents Introduction...3 Valve compatibility...3 Features...3 Application examples...3 Ordering...3 Operating the EKC 347...4-5
More informationEXD-HP1/2 Stand-alone Superheat/Economizer Controller
Technical Bulletin EXD-HP1/2 are stand-alone universal superheat and or economizer controllers for heat pumps, heating units, air conditioning and precision cooling such as telecom and shelter applications.
More informationTEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers Catalog Page
Code. LIT-1900896 Issued February 17, 2017 TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers Catalog Page Description The TEC3000 Series Thermostat
More information0LLCD003EN STANDBY NORMAL INFO MENU INFO DATA SETUP MENU PARAMETER VALUE. Not Product Air Display scale Operating Temper. (sim.
0LLCD003EN LCD15 Thank you for having chosen an LAE electronic product. Before installing the instrument, please read this instruction booklet carefully in order to ensure safe installation and optimum
More informationMETEOROLOGICAL INSTRUMENTS
METEOROLOGICAL INSTRUMENTS INSTRUCTIONS MARINE WIND TRACKER MODEL 06206 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com
More information02/11/2015
MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS
More informationNew LAE controller for Plug-in cabinets
From: Lonardi [MC] To: Price-list owners Ref.: P-6.006/01 Date: 19/03/01 New LAE controller for Plug-in cabinets Dear Sirs, with the aim of a continuous improvement we are going to introduce our new LAE
More information02/11/2015
CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint
More informationHIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER
This manual must be left with owner and should be hung on or adjacent to the boiler for reference. US HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER MODELS CHS-85 through CHS-399 APPENDIX A CONTROLLER
More informationSingle pressure controls for Refrigeration, Air-conditioning and Heatpump applications
Series P77 Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications Product bulletin These pressure controls are designed for use in a variety of applications involving refrigeration
More informationNOVUS AUTOMATION 1/5. Range: -35 to 720 C (-31 to 1328 F) Range: -90 to 1300 C (-130 to 2372 F) Range: 0 to 1760 C (-32 to 3200 F)
E N R S B Pt100 Pt100 Range: -35 to 720 C (-31 to 1328 F) Range: -90 to 1300 C (-130 to 2372 F) Range: 0 to 1760 C (-32 to 3200 F) Range: 0 to 1760 C (-32 to 3200 F) Range: 150 to 1820 C (302 to 3308 F)
More informationAmmonia Leak Detector Manual
Ammonia Leak Detector Manual Document No. 70-PHW-1023-R2.5 No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical,
More informationCM3500 Controller - ClimateMaster DOAS Water-Source Heat Pumps - Rev.: 7 Oct, 2008B
2 CM3500 Controller - ClimateMaster DOAS Water-Source Heat Pumps - Rev.: 7 Oct, 2008B CAUTION CAUTION - ONLY TRAINED, QUALIFIED PERSONNEL SHOULD INSTALL AND/OR SERVICE CLIMATEMASTER EQUIPMENT. SERIOUS
More information1.0 Digital Controller
1.0 Digital Controller...1 1.1 Display Function Keys...1 1.2 Thermostat Display...2 1.3 Controller hardware input output points... 4 2.0 Sequence of Operation...5 2.1 States of Operation...5 2.2 Modes
More informationPump-Up Controller MODEL 4062
Pump-Up Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4062 Pump-Up
More informationRectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English
Rectifier RC-series Manual RC-series English Manual Wall and 19 English Presentation The RC-series is a rectifier for either directly powering the load or for use together with batteries. It is designed
More informationCorrigo E. Second generation which contains all applications and languages
revision 05 2009 Corrigo E Second generation which contains all applications and languages The controllers in the Corrigo E series are intended for applications within heating, boiler and ventilation control
More informationUser s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas
User s Manual TIGER S EYE E-Series Mark V Jockey TIGERFLOW Systems, Inc. 4034 Mint Way Dallas, Texas 75237 214-337-8780 www.tigerflow.com TABLE OF CONTENTS Introduction... 4 Sequence of Operation... 5
More informationEWCM 900/S rel. 5/2000 ing
cod. 9IS40178 EWCM 900/S rel. 5/2000 ing compressors and fans manager WHAT IT IS The EWCM 900(/S) is a series of controllers designed specifically for the control of a machine room in a refrigeration system.
More informationMETEOROLOGICAL INSTRUMENTS
METEOROLOGICAL INSTRUMENTS INSTRUCTIONS WIND TRACKER MODEL 06206 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com
More informationDanfoss gas detection units
Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning
More informationIndex. 1. General description of the application Types of units controlled Types of regulation Condensation...
LCS pco ADVANCED MICROPROCESSOR USER MANUAL GB Index 1. General description of the application... 4 1.1. Types of units controlled...4 1.2. Types of regulation...4 1.3. Condensation...4 1.4. Safety devices
More informationEasyTronic III MANUAL SERVICE
rev.6 EasyTronic III MANUAL SERVICE General characteristics: Power supply 24 Vac ±15% Max consumption at 24Vac 300mA Relay outputs 6 Maximum relay current 8 A res. Serial standard RS232 2 Serial standard
More informationF4 Process Controller Installation and Operation Guide
F4 Process Controller Installation and Operation Guide 1.Introduction 1.1.Highlight Features Space saving, only 55mm panel depth required Higher sampling rate (1mS) results in better control performance
More informationDYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers
High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER
More informationELECTRONIC HUMIDISTAT: H200
ELECTRONIC HUMIDISTAT: H00 ONE OR TWO STAGES DESCRIPTION The H00 series low voltage, microcomputerbased PI (proportional and integral) humidistats are designed for accurate humidification and/or dehumidification
More informationAir-condensed water chillers and heat pumps YLCA / YLHA 100, 120 and 150
Air-condensed water chillers and heat pumps YLCA / YLHA 100, 120 and 150 User manual Ref.: N-40291_EN 1110 Index Index 1 User manual...1 1.1 General description of the unit...2 1.1.1 Models available and
More informationCommunications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)
TEMPERATURE CONTROLLER DIN-sized (96 x 96-mm) Temperature Controller Featuring Advanced PID Control and Heater Burnout Detection Advanced PID control with two degrees of freedom to improve stability and
More informationMODEL MARINE WIND TRACKER
MODEL 06206 MARINE WIND TRACKER NOVEMBER 2001 MANUAL PN 06206-90 R. M. YOUNG COMPANY 2801 AERO-PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, U. S. A. TEL: (231) 946-3980 FAX: (231) 946-4772 MODEL 06206 MARINE
More informationPump-Down Controller MODEL 4052
Pump-Down Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4052 Pump-Down
More informationSeries P215LR/BR Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)
PSC9713 European Refrigeration Controls Catalogue Catalog Section 4 Product Bulletin Series Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression
More informationPROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS
PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min
More informationOVEN INDUSTRIES, INC.
OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and
More information