1 DIWH SERIES ELECTRICAL INSTANT WATER HEATERS STANDARD SPECIFICATIONS OPTIONAL SPECIFICATIONS PLACE OF USAGE PRODUCT DESCRIPTION DIMENSION AND SPECIFICATIONS GENERAL STRUCTURE TANK ELEKTRICAL COMMAND PANEL: POWER AND CONTROL SYSTEM INSTALLATION SCHEMATICS SELECTION GUIDE *** Click the titles in order to access the relevant section *** Diko Electrical Equipments Ind. and Trade Corp. IMES Sanayi Sitesi B Blok. 206 Sok. No:6 ZIP Code:37775 Dudullu - ISTANBUL / TURKEY Phone: Fax: info@diko.com.tr 1
2 DIWH SERIES Electrical Instant Water Heaters STANDARD SPECIFICATIONS Wall Mounted Monoblock design as long with it s electric command panel Digital thermostat - thermometer Temperature adjustment range : (15-51) C All wetted parts constructed of stainless steel Power steps control 24V AC operating voltage for control circuit Human life protection system (residual current device) Protection system against waterless operation Temperature and pressure safety relief valve (T&P Valve) IP24 protection class Special mounting feet for installation Smart appearance 5 year guarantee OPTIONAL SPECIFICATIONS Power range : kw Voltage range : V On your demand available for Hz operating frequency Stainless steel outer jacket 2
3 STANDARD SPECIFICATIONS Digital Thermostat - Thermometer Provided for digital temperature adjustment. User can read the temperature value from the lighted digital screen. Heating Elements Immersed type, 304 quality stainless steel or incoloy sheated stainless steel electric heating elements with 6 8 9,5 mm diameter, MgO insulation, Cr-Ni material, U pipe. Available in various power rates, either as 3Phase or Single Phase. Incoloy sheated heating elements specially designed considering corrosive areas. This incoloy sheated immersion heating elements are much more everlasting for areas with mildy water. Min. Watt density for all heating elements is (7,75 11,63) Watt/cm 2. Safety Thermostat Provides tank protection via breaking electric circuit of the heaters unless tank water temperature level passes over operating temperature value. Ask for technical confirmation if you need to change this factory default setting. Power Steps Control Total power is divided into 3 groups with the help of the switches placed on panel cover. Tank will heat at full load if all three switches are on. You can control the heating power via turning some of the switches off during summer time when there is no need for full capacity heating power 3
4 24V.AC Reduced Command Circuit Voltage Diameter and insulation values of command cables are lower than energy cables. This disadvantage is being eliminated via using devices with low voltage. Human Life Protection System (Residual Current Device / Ground Fault Circuit Interrupter) Residual current devices are designed to prevent electrocution by detecting the leakage current, which can be far smaller (typically 5-30 milliamperes) than the currents needed to operate conventional circuit breakers or fuses (several amperes). Residual current devices are intended to operate within milliseconds inorder to provide human life protection. Protection & Warning System Against Waterless Operation (Light) This system stops the operation and starts warning the operator with light inorder to provide protection for the heating elements incase the tank is empty or water level of the tank is low. Warning System Against Over Heating Safety Thermostat will break the circuit incase the tank water temperature level will pass over the limits. Heating will stop and warning system will warn the operator with light. Temperature and Pressure Safety Valve _ T&P Valve T&P valve is a mechanical safety accessory against excessive heat and pressure. It discharges at max.99 C and/or at max. 10,4bars. 4
5 PLACE OF USAGE Villas Summer Houses Gyms Constuction Sites Container Farm Houses Green Houses Milk Farms Beauty Saloons Offices and Bureaus 5
6 PRODUCT DESCRIPTION DIWH Serie designed and constructed as a monolock heating system with its electric command panel in order to heat fresh water. This electric command panel is equipped with first quality electric components. It will be ready to operate as soon as finalizing the end connections of the energy supply line. Internal electric installation design of the panel provides easy access during maintenance, commissioning and operation. An authorized techician or operator can easily commission and operate the heater. User can adjust and follow the temperature value with the help of digital panel. Also the operation of the heating elements, waterless operation and over heating can be followed with the help of this unique command panel. DIWH Series heating capacity range is between 6KW - 30KW and production with different voltage values is possible. This Serie provides instant hot water with safe operation for ground applications as long with its special designed safety features like human life protection system. In addition to DIWH Serie, DIWH-MP Serie provides hot water for marine and naval applications. up 6
7 DIMENSIONS and SPECIFICATIONS DIWH SERIES DIMENSIONS and SPECIFICATIONS A Panel Depth 110 mm B Panel Width 160 mm C Panel Height 520 mm D Production Height 610 mm E T&P Valve Height 510 mm F Product Diameter 250 mm Cold Water Input ½ Hot Water Output ½ Standard Inner Tank Material ASTM 304L Optional Inner Tank Material ASTM 316L Optional OuterJacket Material ASTM 304 / 316 Approx. Weight kg 7
8 GENERAL STRUCTURE General structure of DIWH Serie is consist of the water tank, T&P safety valve, insulation, outer cover and electric command panel. In this part you will see the descriptions of the both standart and optional factory settled & tested equipments and systems of the product. Please contact us if you ll request additional features for your special projects and process applications. No Hardware Name No Hardware Name 15 Heating Element House 22 Mechanical Thermostat or Thermostat with Gas 16 Heating Element 23 Outer Jacket 17 Mechanical Thermostat 24 Upper Cover 18 Mechanical Thermostat Probe 25 Lover Cover 19 Probe for water level 26 Brace Feet 20 Probe of the thermostat 21 Probe of the digital thermostat 27 T&P Safety Relief Valve 8
9 TANK 1. MATERIAL AND COATING Heating element house constructed of ASTM 304L quality stainless steel for maxiumum endurance. 2. CONNECTIONS Female NPT connections on cold water input, hot water output and on safety valves. Also there is a connection port for the T&P Valve which discharges incase over heating and excessive pressure. 3. SUPPORTS Electric command panel is mounted to the main body with flaps and main body designed as to be screwed to ground with bolts. DISCHARGE VALVE ASME and CSA rated T&P Safety relief valve is standart on DIWH Serie in order to protect the system against over heating and excessive pressure. NPT male and female output connections, thermo unit with special coat, test lug, thermostat and brass body are some of the fatures of the T&P Valve. Discharge temperature = 99 C and discharge pressure = 10,4 bar. (Imported / USA) 9
10 ELECTRIC COMMAND PANEL : POWER AND CONTROL SYSTEM No Hardware Name No Hardware Name 1 Cable Sleeve 8 Contactor Group 2 Electric Panel Door 9 Command Fuse 3 On / OFF switches of the power steps (With light) 10 Water Level Relay 4 Signal Lamps 11 Connector Fuse 5 Digital Thermostat 12 Cable Canal 6 Stopper 13 Transformator 7 Leakage Current Relay 14 Rail 10
11 INSTALLATION SCHEMATIC 11
12 FLOW & POWER & TEMPERATURE DIFFERENCE PRODUCT SELECTION CHART Required Power (KW) 40 50,2 55,8 61,4 67,0 72,6 78,1 83,7 89,3 94,9 100, ,5 51,6 56,8 62,0 67,1 72,3 77,4 82,6 87,8 92, ,7 47,4 52,2 56,9 61,7 66,4 71,2 75,9 80,7 85, ,9 43,3 47,6 51,9 56,2 60,6 64,9 69,2 73,5 77, ,2 39,1 43,0 46,9 50,8 54,7 58,6 62,5 66,4 70,3 Flow (liter /min) 25 31,4 34,9 38,4 41,9 45,3 48,8 52,3 55,8 59,3 62, ,6 30,7 33,8 36,8 39,9 43,0 46,0 49,1 52,2 55, ,9 26,5 29,2 31,8 34,5 37,1 39,8 42,4 45,1 47, ,1 22,3 24,6 26,8 29,0 31,3 33,5 35,7 38,0 40, ,3 18,1 20,0 21,8 23,6 25,4 27,2 29,0 30,8 32, ,6 14,0 15,3 16,7 18,1 19,5 20,9 22,3 23,7 25,1 7 8,8 9,8 10,7 11,7 12,7 13,7 14,7 15,6 16,6 17,6 4 5,0 5,6 6,1 6,7 7,3 7,8 8,4 8,9 9,5 10,6 18 C 20 C 22 C 24 C 26 C 28 C 30 C 32 C 34 C 36 C Temperature Difference ΔT( C) FORMULLAS Flow = m = (Q x 860) (60 x ΔT) Temp. Difference = ΔT = (Q x 860) (60 x m) Power (KW) = Q = (60 x m x ΔT)
DSSY-XM SERIE MARINE TYPE ELECTRIC WATER HEATERS WITH ELECTRICAL COMMAND PANEL
DSSY-XM SERIE MARINE TYPE ELECTRIC WATER HEATERS WITH ELECTRICAL COMMAND PANEL STANDART SPECIFICATIONS OPTIONAL EQUIPMENT AND REQUEST OPTIONS PRODUCT DESCRIPTION PLACE OF USAGE INSTALLATION CONNECTION
More informationDEMK Series Diko Electrical Equipments Ind. and Trade Corp.
DEMK Series Diko Electrical Equipments Ind. and Trade Corp. IMES Sanayi Sitesi B Blok. 206 Street. No:6 ZIP Code:37775 Dudullu - ISTANBUL / TURKEY Phone:+90216 3142626 Fax:+90216 4204901 www.diko.com.tr
More informationMARINE BOILER SOLAREKS - MARINE BOILER BOILER&ELECTRICAL HEATER FOR SHIP SI UNIT CATALOGUE
MARINE BOILER BOILER&ELECTRICAL HEATER FOR SHIP SI UNIT CATALOGUE SOLAREKS - MARINE BOILER Boiler is designed to be used in ships, water can be heated by electrical heaters and engine cooling luquid. While
More informationSOLAREKS - ELECTRIC WATER HEATER
SOLAREKS ELECTRIC WATER HEATER We want every product which we manufacture to be the best quality...i put my name on it SOLAREKS ALPER UYSAL SI UNIT CATALOGUE THREEPHASE INSTANT ELECTRIC WATER HEATER FOR
More informationSOLAREKS ELECTRIC WATER HEATER THREE-PHASE ELECTRIC BOILER FOR INDUSTRIAL USE SOLAREKS - ELECTRIC WATER HEATER SI UNIT CATALOGUE
ELECTRIC WATER HEATER We want every product which we manufacture to be the best quality...i put my name on it ALPER UYSAL SI UNIT CATALOGUE THREEPHASE ELECTRIC BOILER FOR INDUSTRIAL USE Electric boiler
More informationProcess Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW
MODEL V Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW Features Industrial Grade Construction Stainless steel pressure vessel provides maximum service
More informationPackaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase
Features Heavy Duty Construction Constructed with high grade materials to ensure long operating life Turn-Key package is simple to specify and operate Factory wired electrical controls provide trouble-free
More informationEHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION
EHB Series STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal STONESTEEL is a registered trademark of Cemline Corporation CEMLINE CORPORATION P.O. BOX 55
More informationShipboard Electric Water Heater
Marine Products Division Model MSE Shipboard Electric Water Heater 6-120 Gallon Capacity, Three Phase Voltages Up To 58 KW, Single Phase Voltages ver 6 KW Heavy Duty Construction n Hydrastone cement lining
More informationShipboard Electric Water Heater
Marine Products Division Model MSE Shipboard Electric Water Heater 6-119 Gallon Capacity, Three Phase Voltages Up To 58 KW, Single Phase Voltages ver 6 KW Heavy Duty Construction n Hydrastone cement lining
More informationTrueTech Energy TT - HYD Series
FW&SW HYDROPHORE SET The TT - HYD series is available with storage capacities from 100 to 2,000 Liters. All tanks feature ASME / EN tank construction. SEAWATER & FRESHWATER HYDROPHORE SYSTEM TrueTech hydrophore
More informationASME Packaged Electric Water Heater
MODEL SH & H ASME Packaged Electric Water Heater 15-1600 KW - All Voltages & Phases, 80-5000 Gallon Capacity Features Reliable Packaged System Only high grade materials used in construction to ensure long
More informationEasy Installation & Service
Water Commercial Electric Heavy Duty Water Heaters Heavy Duty Electric commercial water heaters are available in 50 through 175 gallon capacities. All models quick ship from Rheem warehouses no deposit
More informationAQUA BOILER Jacket Type Horizontal Boiler (Solar Water Heating System Natural Circulated Boiler)
AQUA BOILER Jacket Type Horizontal Boiler (Solar Water Heating System Natural Circulated Boiler) Closed Loop Jacket Type Pressurized Boiler Closed Loop Jacket Type Boilers are used with natural circulated
More informationCommercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages
MODEL SE Commercial Electric Water Heater 6-119 Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages Features Heavy Duty Construction High Efficiency Polyurethane
More informationTankless On Demand Electric Water Heater
ECO FRIENDLY 98% EFFICIENT ENERGY & WATER SAVING Model MTX Tankless On Demand Electric Water Heater Available Up To 54 KW in Single or Three Phase Voltages Marine Approvals American Bureau of Shipping
More informationSOLAREKS - ELECTRIC WATER HEATER
SOLAREKS ELECTRIC WATER HEATER We want every product which we manufacture to be the best quality...i put my name on it SOLAREKS ALPER UYSAL SI UNIT CATALOGUE MONOPHASE ELECTRIC BOILER Solareks monophase
More informationOPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D
OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE:
More informationFCT-CE SERIES ELECTRIC TILTING KETTLE W/HAND CRANK PARTS AND SERVICE MANUAL
FCT-CE SERIES ELECTRIC TILTING KETTLE W/HAND CRANK PARTS AND SERVICE MANUAL EFFECTIVE SEPTEMBER 12, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the
More informationSOLAREKS ELECTRIC WATER HEATER WALL HUNG ELECTRIC BOILER FOR RESIDENTIAL USE SOLAREKS - ELECTRIC WATER HEATER
SOLAREKS ELECTRIC WATER HEATER We want every product which we manufacture to be the best quality...i put my name on it SOLAREKS ALPER UYSAL WALL HUNG ELECTRIC BOILER FOR RESIDENTIAL USE SOLAREKS ELECTRIC
More informationIndirect Fired Water Heater
Indirect Fired Water Heater 35-119 Gallon Capacities Features Heavy Duty Construction Hydrastone cement lining provides long tank life Copper-silicon tappings cannot rust or corrode High impact composite
More informationService Manual ES50LVS / ES90LVS MULTI-SPEED AIR HANDLER. Ecosmartair 105 Haist Avenue, Unit 10 Vaughan, ON L4L 5V ecosmartair.
ES50LVS / ES90LVS MULTI-SPEED AIR HANDLER Service Manual Ecosmartair 105 Haist Avenue, Unit 10 Vaughan, ON L4L 5V6 905-857-9755 ecosmartair.com P/N 14009A 1 P a g e Contents CONTROL ASSEMBLY LAYOUT...
More informationELECTRIC SPA-PAK HEATER INSTALLATION & OPERATING INSTRUCTIONS
ELECTRIC SPA-PAK HEATER INSTALLATION & OPERATING INSTRUCTIONS CATALOG NO.: 6100.53O Effective: 03-15-05 Replaces: 02-01-05 INTRODUCTION The SPA-PAK Spa Heaters have been designed to provide efficient,
More informationSNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions
Pre-assembled skid system Back-to-Back heater models, SNA & SNAR High Flow Demand Safety Shower Applications 216-288 kw (737,000-983,000 BTUs) Temperature overshoot purge system NEMA 4 enclosure standard
More informationCF1 ProVector Explosion-Proof Heaters
CF1 ProVector Explosion-Proof Heaters The CF1 Series ProVector Explosion-proof convection heater offers the most reliable, dependable and trouble-free service available for heating hazardous locations
More informationControl and power circuit fusing to meet N.E.C.
LARGE VOLUME ELECTRIC WATER HEATERS SEV & SEH MODELS Commercial Electric ADVANCED State s new propriety electronic water heater control, provides precise + or - 1ºF temperature control, that is ideal for
More informationINSTALLATION AND SERVICE MANUAL
INSTALLATION AND SERVICE MANUAL Electric Power Water Heater 12kW 162kW NOTE: retain this manual for future reference Installation and service must be performed by Qualified Service Personnel Only. WARRANTY:
More informationTABLE 1 Electrical Specifications. Phase
CHRONOMITE HIGH CAPACITY INSTANT-TEMP WATER HEATERS INSTALLATION AND OPERATION INSTRUCTIONS (208-240V 3 Φ Models) (Before installation, compare electrical requirements needed for the model of heater selected)
More informationDiscontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications
36-144 kw (122,800-491,300 BTUs) Temperature overshoot purge system Certified Lead-Free Design NEMA 4 enclosure standard ASME and NB Certified options available Pressure Drop Advantage Dual Flow Activation
More informationTankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages
Model HX/TX Tankless Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages Features Heavy Duty Construction Constructed with high grade materials to ensure long operating
More informationTable of Contents. FETCO, and Driven To Pioneer Innovation are trademarks or trade names of Food Equipment Technologies Company.
www.fetco.com Hot Water Dispensers User s Guide Maritime Versions Rated IP44 Table of Contents Contact Information... 2 Specifications... 2 Dimensions... 3 Installation... 4 Operating Instructions...6
More informationC1N Series - Light Industrial Heaters Tankless Water Heating Solutions
18-25 kw (61,4000-85,300 BTUs) Low flow activation options at 0.25 and 0.50 GPM (1.0 and 1.9 LPM) Certified Lead-Free Design Variable Temp Heat Exchanger Pressure Drop Advantage NEMA 4 enclosure standard
More informationShipboard Electric Water Heater
Marine Products Division Model ME Shipboard Electric Water Heater 6-119 Gallon Capacity, Up To 12 KW, Single Phase Marine Approvals United States Coast Guard (USCG) conformance and American Bureau of Shipping
More information"ER" Series Electric Humidifier
ER-1 Standard Water "ER" Series Electric Humidifier The Electric Humidifier from PURE Humidifier Co. is loaded with features and options. All you need is tap water, electricity, and a sanitary drain the
More informationInstallation, operating and servicing instructions
English 57-115 - 144-1 - 259 Installation, operating and servicing instructions ITALIA EN 1 ITALIA English INDEX WARnINGS 3 Who should read these instructions 3 Symbols 3 Recommendations 3 Importants notes
More informationPortable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions
Portable C2N Series - Light Industrial Heaters Heavy duty industrial cart options simplify moving heater to various locations 36-50 kw (122,800-170,600 BTUs) Variable Temp Heat Exchanger Pressure Drop
More informationPortable C1N Series - Light Industrial Heaters Tankless Water Heating Solutions
Heavy duty industrial cart options simplify moving heater to various locations 18-25 kw (61,4000-85,300 BTUs) Low flow activation options at 0.25 and 0.50 GPM (1.0 and 1.9 LPM) Certified Lead-Free Design
More informationCNA-Series - Large Industrial Heaters Tankless Water Heating Solutions
36-144 kw (122,800-491,300 BTUs) Certified Lead-Free Design New & Improved Pressure Drop Advantage Variable Temp Heat Exchanger NEMA 4 enclosure standard Independent Safeties ETL and cetl certified to
More informationSN Series - Safety Shower Heaters Tankless Water Heating Solutions
36-144 kw (122,800-491,300 BTUs) Temperature overshoot purge system Lead-Free Design NEMA 4 enclosure standard ETL and cetl certified to UL and CSA Standards Liquid-Cooled Solid State Relays Internal fusing
More informationCirculation Heaters. To order, call or shop online at omega.com SM. CHF Series
CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is
More informationKIT NOTICE. These instructions are for replacing the two existing thermostats with a single new solid-state thermostat.
KIT 06401-004-22-16 5 1 2 NOTICE 3 (3 PLC'S) These instructions are for replacing the two existing thermostats with a single new solid-state thermostat. 4 PREPARATION PARTS INCLUDED 6 1 7 5 8 2 4 (4 PLC'S)
More informationKeltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions
36-144 kw (122,800-491,300 BTUs) Temperature overshoot purge system Certified Lead-Free Design NEMA 4 enclosure standard ASME and NB Certified options available New & Improved Pressure Drop Advantage Dual
More informationSECTION DOMESTIC WATER HEATERS
SECTION 223500 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to
More informationPROVIDES TEPID WATER FOR EMERGENCY SHOWER
PROVIDES TEPID WATER FOR EMERGENCY SHOWER Model EMV FEATURES Heavy Duty Construction Hydrastone cement lining provides tank longevity Copper-silicon alloy tappings cannot rust or corrode High impact composite
More informationINSTALLATION GUIDE. Condensing unit for refrigeration plant. RCWC10D/22 380V 50/60Hz Seawater. Model. Installation manual RCWC10D/22 IM- RCWC10D/22 1
INSTALLATION GUIDE Condensing unit for refrigeration plant. Model RCWC10D/22 380V 50/60Hz Seawater Installation manual RCWC10D/22 IM- RCWC10D/22 1 Contents Hazards and safety precautions - 3 - General
More informationPipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual
MANUAL Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual Model FPT 130 Single Point Freeze Protection Heat Trace Control Table of Contents SCFP-CO-F130 Overview... 3 Installation...
More informationIndustry Best 10 Year Commercial Warranty
Medium Dut y Advanced Heating & Hot Water Systems Single Phase or 3 Phase Operation Field Convertible Models: to 1 Gal. Large Volume 3 Phase Commercial Point of Use Single Phase Only Junction Box & Terminal
More informationA B A B4
TM TM SERVICE INSTRUCTIONS Thermo-Aire Heater Kits and Air-Heater Assemblies 383808-A4 383808-B4 383880-A4 383880-B4 DESCRIPTION The Thermo-Aire Heater is used in situations where oils of heavier viscosity
More informationTABLE 1 Electrical Specifications
CHRONOMITE HIGH CAPACITY INSTANT-TEMP WATER HEATERS INSTALLATION AND OPERATION INSTRUCTIONS (208-240V Models) (Before installation, compare electrical requirements needed for the model of heater selected)
More informationEB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508
Electro-HELPS IX Boiler, Submittal Data Sheets These provide the mechanical technical details often required for architects/design engineers, shop drawings, etc. They are also useful in providing additional
More informationLeak Detection System Leak Minder Model: LDA-1 Instruction Manual
JWB Company Leak Detection System Leak Minder Model: LDA-1 www.jwbcompany.net Instruction Manual JWB Company For Support and Service: 65 August Avenue Wolcott, CT 06716 (203) 879-6959 (203) 879-7299 FAX
More informationMULTI ELEC. Electric Boilers TECHNICAL MANUAL
MULTI ELEC Electric Boilers TECHNICAL MANUAL PO Box 11 Ashton Under Lyne OL6 7TR +44. (0) 161 621 5960 Fax +44. (0) 161 621 5966 info@atlantic2000.co.uk www.atlanticboilers.com 2 CONTENTS DESCRIPTION....
More informationMARINE BOILERS YACHT BOILER SOLAREKS - MARINE BOILER SI UNIT CATALOGUE
MARINE BOILERS SI UNIT CATALOGUE YACHT BOILER - MARINE BOILER - MARINE BOILER Boilers are designed to be used in yachts. Water can be heated with engine cooling liquid and electrical heater. While the
More informationPortable CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions
Portable CNA-Series - Large Industrial Heaters Heavy duty industrial cart options simplify moving heater to various locations 36-72 kw (122,800-245,600 BTUs) Certified Lead-Free Design New & Improved Pressure
More informationOPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER. ELECTRIC HEATER COMPANY BASE MODEL SH and H
OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL SH and H HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203) 378-2659
More informationHeat Pump Water Heater
MODEL PBX Heat Pump Water Heater Fully Integrated Heat Pump Water Heater (HPWH) 40-119 Gallon Capacity Features Highest Efficiency Heat Pump transfers heat from surrounding air into the hot water tank
More informationGTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts
GTIP60 ISO GT Series, Inch Pounds 60 Hz GT010070 (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts Rev: 903 Rev 1 Revisions: 31103 Changed HZ dwg to field convertible 5902 changed Unit
More informationCirculation Heaters. To order, call or shop online at omega.com SM. CHF Series
CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is
More informationCirculation Heaters. To order, call or shop online at omega.com SM. CHF Series
CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is
More informationCirculation Heaters. To order, call or shop online at omega.com SM. CHF Series
CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is
More informationELECTRIC BOILERS. RANGE 1kW to 980kW ABOUT ATLANTIC ELECTRIC DOMESTIC HOT WATER HEATERS. WATER HEATERS 445 to 7520ltrs/hr
1kW to 980kW WATER HEATERS 445 to 7520ltrs/hr ELECTRIC BOILERS ELECTRIC DOMESTIC HOT WATER HEATERS ABOUT ATLANTIC ATLANTIC BOILERS was formed in 1980 to promote highly efficient boilerplant and within
More informationCirculation Heaters. To order, call or shop online at omega.com SM. CHF Series
CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the is immediately
More informationCirculation Heaters. To order, call or shop online at omega.com SM. CHF Series
CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is
More informationECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL
ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL EFFECTIVE JULY 31, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution
More informationSERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models
Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models SERVICE MANUAL Troubleshooting Guide and Instructions for Service (To be performed ONLY
More informationITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual
ITC 2000 HEATING CONTROL CABINET Installation & Operation Manual VTI, Incorporated 24 McMillan Way Newark, DE 19713 Phone (302) 738 0500 FAX (302) 738 6594 Revision Level 0.03 Manual No. 90003314 June,
More informationCX1 ProVector Explosion-Proof Heaters
Explosion-Proof Heaters For hazardous locations heating, rely on the for the most dependable, troublefree service available. CCI Thermal Technologies Inc. manufactures explosion-proof air heaters to satisfy
More informationCommercial Electric Energy Saver Water Heater IMMERSION AND SURFACE MOUNTED THERMOSTAT MODELS
Energy Saver Commercial Electric Energy Saver Water Heater IMMERSION AND SURFACE MOUNTED THERMOSTAT MODELS SERVICE MANUAL Troubleshooting Guide and Instructions for Service (To be performed ONLY by qualified
More informationL A signature series TA T N E RE O, A L L A T S IN
signature series COMMERCIAL STEAM GENERATORS INSTALLATION, OPERATION AND MAINTENANCE MANUAL INSTALLATION MANUAL COMMERCIAL STEAM GENERATOR SIGNATURE SERIES (SS) INTRODUCTION Steam Sauna manufactures steam
More informationCirculation Heaters Selection Guidelines
Selection Guidelines Selecting a Circulation Heater Application Factors Corrosion Policy Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation
More information! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or
I&M NUMBER: 316-42-10-1 Page: 1 Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to
More informationCONTENTS Warranty Start-Up Procedure Installation Requirements Maintenance Trouble Shooting Electrical Service Components and Controls
Warranty..........................1 Safety Warnings................1 Checking the Equipment..........1 Codes........................4 Installation Requirements Location......................4 Drain Pan
More informationSAFETY INFORMATION AND WARNINGS
This manual refers to the Model SST-3 control panel manufactured since October 31, 2013, which uses a universal (100 277 VAC; 50/60 Hz) power supply. Older units use a voltage-specific power supply and
More informationSingle Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual
We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER
INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL T Edition 0 HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 88 STRATFORD, CT 0665
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR THE HUBBELL MODEL TX / HX TANKLESS WATER HEATER
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR THE HUBBELL MODEL TX / HX TANKLESS WATER HEATER ELECTRIC HEATER COMPANY Edition 2012A HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615-0288
More informationIndustrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version
heating for a better future Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version HEATING GASES HEATING LIQUIDS The CETAL-developed Cast-In Circulation Heater Technology
More informationWATLOW ELECTRIC MFG CO. FIREBAR Screw Plug Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.
I&M NUMBER: 316-42-3-1 Page: 1 Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to elements
More informationKIT NOTICE. These instructions are for replacing the three existing thermostats with a single new solid-state thermostat.
KIT 06401-004-22-16 5 1 2 NOTICE 3 (3 PLC'S) These instructions are for replacing the three existing thermostats with a single new solid-state thermostat. 4 PREPARATION PARTS INCLUDED 6 1 7 5 8 2 4 (4
More informationTubular Industrial Process
consist of tubular elements welded or brazed into a threaded screw plug which can then be inserted into a threaded opening in a tank wall or through a mating full or half coupling. Standard Screw Plug
More informationKOSPEL S.A KOSZALIN UL. OLCHOWA 1
Please, read and follow the installation and operating instructions carefully, to ensure the long life and reliable operation of this appliance. Kospel S.A. may make minor changes if necessary, in the
More informationDescription. Applications
CVEP PDS CVEP Convection for Hazardous Heater For Locations Hazardous Locations Convection Heater 1.8 to 9.0kW (T-2A) 280 C (536 F) 1.6 to 4.0kW (T-3A) 180 C (356 F) 1.8 to 9.0kW (T-2) 1.8 300 C to 9.0kW
More informationBENEFITS. Standard 2-3. HCFC S (hydrochlorofluorocarbons), CFC S (chlorofluorocarbons) nor VOC s (volatile organic compounds). Hot water.
RESIDENTIAL ELECTRIC WATER HEATERS STANDARD, CASCADE, SUPER CASCADE & ECOPEAK TECHNOLOGY 30 I 40 I 60 I IMP. GALLONS BENEFITS 1 - FACTORY INSTALLED TEMPERATURE & PRESSURE-RELIEF VALVE Protects the tank
More informationQUICK START GUIDE 04 WARNING 05 PACK CONTENTS 05 TECHNICAL SPECIFICATIONS 05 ELECTRICAL REQUIREMENTS 05 WIRING DIAGRAM 07 INSTALLATION OPTIONS
Congratulations! You've just purchased a new Power Pak Plus tankless water heater and will soon begin to enjoy the benefits of going tankless. Please take the time to thoroughly read and understand this
More informationSM Field Installed Electric Heat Kit
SM Field Installed Electric Heat Kit HK050 HK100 HK150 HK200 Installation Manual 8733822029 (2018/07) US 2 SM Series Electric Heat Installation Manual Data subject to change 07.2018 8733822029 Installation
More informationResidential & Commercial
Residential & Commercial Effective May 2017 Product Catalog Complete Line www.americanstandardwaterheaters.com Setting The New Standard Tankless Condensing Water Heaters Available in 180,000 & 199,000
More informationUSER GUIDE ENGLISH TOPSTART Ref. TSWZ, TSWRS or TSG Between 0.5 and 3 kw
The TopStart is a compact electric coolant heater with circulating pump for marine engines, generating sets and all types of vehicles located inside or outside (protected place only). TABLE OF CONTENTS
More informationInstallation Instructions
Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A, Z Chassis Installation Instructions NOTE: Read the entire instruction manual before starting
More informationML-758 Parts Manual. Phase 7 / Non-Coin / Dual Timer with F.S.S. Options
ML-758 Parts Manual Phase 7 / Non-Coin / Dual Timer with F.S.S. Options American Dryer Corporation 88 Currant Road Fall River, MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 E-mail: techsupport@amdry.com
More informationFlange Heaters Type CX
pplication Flange heaters are used to heat liquids or gases in tanks or in-line vessels. Safe and reliable service from the heater requires the correct selection of materials and heating element watt density.
More informationHeat Pump Water Heater. Table of Contents
Table of Contents INTRODUCTION... 3 SAFETY... 3 Electrical... 3 R410a Refrigerant... 3 Scalding... 3 Flammable Vapors... 3 COMPONENT PARTS OF THE HEAT PUMP WATER HEATER... 4 TOOLS... 10 OPERATIONAL MODES...
More informationPOINT HELIDECK LIGHTS PRL-LSM LED LOW SURFACE MOUNT LIGHT
Compliances: ETL Listed to UL 98 US & CSA C22.2 No..-4 Canada ETL Listed to UL 98A Marine Vessels IMO 9 MODU Code () paragraph 13.. FAA AC /39-2B Heliport Design Guide ICAO Annex 14, Volume II UK CAA CAP
More informationC D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product
Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is immediately
More informationPrecision Storage Vessels ELECTRIC WATER HEATERS
Precision Storage Vessels ELECTRIC WATER HEATERS High Capacity Electric Water Heaters Electric calorifiers are one of the easiest method of generating hot water for both domestic and industrial application.
More informationMODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A
MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com
More informationTECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA
TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA ARGO 245C / 3SC Cooling only model ARGO 235H / 3HP Heat pump model 0.8180.405.2 09/2006 Table of contents Page A SPECIFICATIONS 1) Unit specifications 3
More informationSITESTAR CABINET DESCRIPTION
SITESTAR CABINET DESCRIPTION Product No: D000100/1 Revision: 03 SiteTel Sweden AB Haukadalsgatan 8A, SE-164 40 Kista, Sweden www.northbattery.com Contents 1 INTRODUCTION... 4 1.1 TARGET GROUP...5 1.2 DOCUMENTS...5
More informationLight Duty Commercial Electric Water Heater
MODEL E Light Duty Commercial Electric Water Heater 6-120 Gallon Capacity, up to 6 KW, Single Phase and Three Phase Open Delta Features Heavy Duty Construction High Efficiency Hydrastone cement lining
More informationImmersion Heaters. Screw Plug Immersion Heater
Screw plug immersion heaters are ideal for direct immersion heating of liquids, including all types of oils and heat transfer solutions. Available in a variety of sizes, screw plug immersion heaters feature
More informationSTEAMPRO. Steam Generator Troubleshooting and Service Guide
STEAMPRO Steam Generator Troubleshooting and Service Guide TABLE OF CONTENTS Page PREFACE... 1 I. STEAMPRO STEAM GENERATOR SYSTEM...2 II. PLUMBING AND ELECTRICAL...3-4 III. SYSTEM OVERVIEW... 5-10 IV.