Air cooler C 28-1/6. Tools : (The construction varies depending on extracting tool)
|
|
- Helen Hensley
- 5 years ago
- Views:
Transcription
1 Air cooler Structure Horizontal-type Remark): There are 2 types of air cooler that are equipped with and without feed water heater. 6 Tools : (The construction varies depending on extracting tool) 1 Roller plate Each 1 Distance piece 94662a, 94662b, 94662c Each 1 Dismantling and assembling device 94663a, 94663b, 94663c 1 Rail No. Name of article Check item 1 Element Take care about broken 2 Tube sheet 3 Header Coated inside to (In / out side) prevent damage. 4 Header Ditto 5 Side plate 6 Side plate C 28-1/6
2 1-1 Air cooler list No. Eng. Eng.Type Air Cooler Ship Yard Ship No. No. Manufacturer Type No. Heater RTA96C IHI Kure 3086 Suction Gas Engine SWPX-979F/R190A/4 96-A601&A602, Mfg. Co., Ltd. A614&A615 Without RTA96C IHI Kure A267&A270, A269&A RTA96C IHI-MU Kure 3088 SWPX-1586F/R190A/4 97-A363~A RTA96C IHI-MU Kure A514~A RTA96C IHI-MU Kure A645~A RTA96C IHI-MU Kure A075~A RTA96C IHI-MU Kure 3151 CH4F-2293F/R204B/4 01-A208~A210 With RTA96C IHI-MU Kure A283~A RTA96C IHI-MU Kure A351~A RTA96C Koyo 2135 CH6S-1556F/R204B/4 01-A409~A411 Without RTA96C Koyo A451~A RTA96C IHI-MU Kure 3155 CH6S-1945F/R240B/4 02-A037~A RTA96C IHI-MU Kure A152~A RTA96C IHI-MU Kure A178~A RTA96C IHI-MU Kure A272~A RTA96C IHI-MU Yokohama 3163 CH4F-2165F/R240B/4 02-A072~A074 With RTA96C IHI-MU Yokohama A218~A RTA96C IHI-MU Yokohama A353~A RTA96C IHI-MU Yokohama A112~A RTA96C IHI-MU Kure 3167 CH6S-1945F/R240B/4 03-A071~A073 Without RTA96C IHI-MU Kure A128~A RTA96C IHI-MU Kure A264~A RTA96C Koyo 2147 CH6S-1849F/R240B/4 02-A292~A RTA96C Koyo 2148 同上 03-A027~A029 96C 28-2/6
3 1-2 Outline of structure The feature of air cooler for RTA84T type engine is as follows. Flow direction of scavenging air: Air passage in horizontal (left and right) direction (Vertical-type air cooler) Less channeling in tubes even in small quantity of water Feed water heater: With or without heater. Main engine can be run without supply of feed water. Cooling medium: Fresh water 2. Check item 2-1 Periodic checks At time of engine patrol 1) Check the jointing face of casing (inlet side) and air-duct for leakage of scavenging air. (Caution: Be cautions about the scavenging temperature that normally it reaches higher than 140 C.) Measures: Tighten the bolts. Change packing during repair at the dock. 2) Ensure that a small amount of fresh water flows all the time from the air vent. 3) Check the scavenging differential pressure before and after air cooler (the degree of element contamination). 4) Check the gasket and connecting pipe flange in the cooling water chest for leakage of fresh water. 5) If drain from the air duct increase suddenly, the tube of air cooler is in danger of being broken. 96C 28-3/6
4 2-2 Cautions in operation 1) When freshwater is leaking from a broken tube, provide blind plugs in the broken tube, as soon as possible. At the same time, check the inside of the scavenging-space. 2) Carry out the air vent for water line of air cooler at delivery from the port and at checking of M0 system Prevent remaining the air in these lines. (In case of no apply the continuous air vent line) 3) Always confirm the tendency of differential pressure between air cooler inlet air pressure to outlet one, which is measured by manometer, in order to prevent contamination and blockage of cooler airside. 4) Take care not to damage rust-preventive coating (neoprene, hyperons, tar-epoxy and etc.) of the inner face of header. And any damage is discovered, repair it without delay. 5) When stopping the engine for a long period, drain cooling fresh water inside air cooler. Inspection of painting / coating : 1 time / year 2-3 Maintenance at dock 1) As standard at the repair-dock in service, also considering the maintenance results of the air-coolers, to be unloaded this air-cooler and carried out overhauling and cleaning. At this chance, carry out the cleaning / inspection of both cooling water side and air side, also pressure test the leakage of cooling waterside. 2) In the case that the erosion of cavitations etc. was discovered on the inlet side of cooling pipe with the inspection of the air cooler, insert the insertion tube (in case of round tube) in order to prevent the erosion of cavitations etc. 96C 28-4/6
5 2-4 Investigation of air cooler renewal 1) Grasp the condition of air cooler by periodic maintenance / inspection. 2) Make a proper maintenance plan according to the above conditions of the air cooler. In the case that the operation point is not able to obtain the cooling ability of requiring in a short time in spite of after maintenance, consider renewal of the air cooler. 3. Overhaul / reassembly 1) Retightening the bolts when scavenging air leakage happens. Just after overhaul and reassembly, air leak used to occur. 2) Replace the gasket and O-ring by new ones when the header is overhauled. And tighten the bolt clockwise (in the order of 12:00-6:00-3:00-9:00 of clock) 3) Ensure that there are no paint and oil sticking to the surface of protective metal and threads. 3-1 Cleaning on air side Judging criterion for cleaning: To be cleaned before the maximum differential pressure reaches 300mm Aq. Cleaning method: 1) Cleaning by compressed air 2) Cleaning by steam Remove oil contaminated stuff with steam (3 ~ 7 kg/cm², 150 C) 3) Chemical cleaning (consult with the cleaning maker.) When airside is washed by the chemicals, the stain of the upper tube falls to the lower tube by an insufficient washing, then the stain accumulates, and sometimes causes the blockage in the airside. Never heat the cleaning agent higher than 75 C. The cleaning time differs depending on the type of cleaning agent and the condition of dirt. After cleaning is finished, wash the tubes with fresh water to neutralize them. Confirm that the airside is not choked. 96C 28-5/6
6 3-2 Cleaning on water side In case of freshwater cooling, periodically inspect the inside of cooler and wash the cooler if necessary, although there is not the fear of the tube blockade by salt accumulation etc. like seawater cooling. 4. Failure sample 1) Inflow of the cooling water into the scavenging-space due to broken holes of air cooler 2) Water and air leakage due to aging of o-rings and gaskets 5. Technical information Service information DUQ1-059E Preventing maintenance against clogging of scavenge air cooler 96C 28-6/6
Air cooler T 28-1/7
Air cooler 6606 1. Structure Equipped with feed water heater (Horizontal-type) 6 Remark): There are 2 types of air cooler that are equipped with and without feed water heater. Tools : (The construction
More informationSeries 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING
Series 47 and 247 Mechanical Water Feeders McDonnell & Miller Installation & Maintenance Instructions MM-316(C) Series 47-2 and 247-2 Combination Mechanical Water Feeder/Low Water Cut-Off Series 47 Water
More information! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-315(C)
Models 51, 51-S and 53 Boiler Water Feeders Models 51-2, 51-S-2 and 53-2 Feeder Cut-Off Combinations McDonnell & Miller Installation & Maintenance Instructions MM-315(C) OPERATION Maximum Water Supply
More informationInstallation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers
Bulletin 1200/4 (Revised 5/12) Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers INNOVATORS IN HEAT TRANSFER I. INSTALLATION OF HEAT EXCHANGERS A. HEAT EXCHANGER SETTINGS 1)
More informationAC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions
AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY PUMPS WITH MOTORS 1. No assembly required. Unpack the pump and motor and examine for any
More informationINSTALLATION & OPERATING INSTRUCTIONS
INSTALLATION & OPERATING INSTRUCTIONS WARNING RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A CIRCUIT PROTECTED BY A GROUND-FAULT CIRCUIT-INTERRUPTER. THE UNIT SHOULD BE INSTALLED BY A QUALIFIED SERVICE REPRESENTATIVE.
More information4 route 147, C.P.33 Coaticook, Qc J1A 2S8
4 route 147, C.P.33 Coaticook, Qc J1A 2S8 TABLE OF CONTENTS INSTALLATION Nozzles p.3 Clearance for dismantling p.4 Foundations p.4 Foundation bolts p.5 Leveling p.5 Bolted joints p.5 Recommended bolt tightening
More informationWe are helping power generation facilities advance toward the future.
We are helping power generation facilities advance toward the future. Hisaka has a wealth of know-how and experience in heat exchangers using seawater, such as central cooling systems for power stations,
More information9. Check condensate piping for sagging and/or leakage. Repair any sags or leaks before restoring power to the appliance.
77 Do not install the condensate assembly if a component is lost or missing. Replace the entire assembly. Failure to follow this warning could result in property damage, serious personal injury, or death.
More informationVERTICAL GLANDLESS PUMP
VERTICAL GLANDLESS PUMP INSTALLATION, OPERATION AND MAINTENANCE MANUAL INDEX Sl.No CONTENTS Page No. 1 Introduction 02 2 Unpacking 04 3 Installation procedure for VGP (Pump dispatched without motor) 07
More informationSELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H
SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS HP Phase Medium Head High Head 3 1 BMLS 300 M BMLS 300 H 3 3 BMLS 300 M3 BMLS 300 H3 5 1 BMLS 500 M BMLS
More informationEvaporators. Direct Expansion Flooded Recirculated Over Feed
Evaporators Purpose: Liquid Refrigerant is Boiled from a Low Pressure Liquid to a Low Pressure Gas by Absorbing Heat from the Medium that is being Cooled Types: Direct Expansion Flooded Recirculated Over
More informationMODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS
MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS 1. FEATURES The Type N Trap range is particularly suitable for high pressure/high temperature trapping applications
More informationCOOLING / HEATING COILS
COOLING / HEATING COILS GENERAL INSTALLATION OPERATION AND MAINTENANCE COIL TYPES CHILLED WATER / GLYCOL HOT WATER / GLYCOL DIRECT EXPANSION (EVAPORATIVE COOLING) STEAM DISTRIBUTING STANDARD STEAM Type
More informationNiles Steel Tank Hot Water Generator Installation and Operation Manual
Niles Steel Tank Hot Water Generator Installation and Operation Manual Contents: Contents 1 Hazard definitions 1 1. General Information.... 2 Availability... 3 Optional Control Packages... 5 2. Installation....
More informationINSTRUCTION MANUAL FOR OIL BURNER MODELS
INSTRUCTION MANUAL FOR OIL BURNER MODELS X400 Bio B10 E90-803-001-001-03 Rev 13-1 - Contents Technical specifications Technical data... 3 Working field... 3 Dimensions... 4 Head and electrode settings...
More informationWATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00
I&M NUMBER: 316-42-5-1 Page: 1 Pre Installation Check to make sure that heater received is the same as that ordered. Watlow heaters are built to comply with UL and CSA dielectric requirements, it may be
More informationINFINITY FLUIDS CORPORATION
INFINITY FLUIDS CORPORATION INFINITY FLUIDS CORPORATION 344 FRANKLIN STREET WORCESTER, MA 01522 888-565-8137 508-347-3674 CRES PRODUCT: WATER/LIQUID HEATER AIR/GAS HEATER INLINE/INSTANTANEOUS STEAM GENERATORS
More informationINSTRUCTION MANUAL UFO3-BN UFO3F-BN UFO3-CN FREE BALL-BUCKET STEAM TRAP UFO SERIES. Copyright (C) 2007 by TLV Co., Ltd. All rights reserved.
INSTRUCTION MANUAL FREE BALL-BUCKET STEAM TRAP UFO SERIES UFO3-BN UFO3F-BN UFO3-CN Copyright (C) 2007 by TLV Co., Ltd. All rights reserved. Introduction Before beginning installation or maintenance, please
More informationGENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.
Fig. 2: Blower & Evaporator Unit Specifications 2004 HVAC SYSTEMS Manual HVAC System - Sorento GENERAL SPECIFICATIONS AIR CONDITIONER Fig. 1: Air Conditioner Specifications BLOWER AND EVAPORATOR UNIT HEATER
More informationA/C COMPRESSOR OIL CHECKING
A/C COMPRESSOR OIL CHECKING 1990 Nissan 240SX 1990 AIR CONDITIONING & HEAT Compressor Oil Checking ISOLATING COMPRESSOR NOTE: Only compressors with stem-type service valves can be isolated. 1) Connect
More informationINSTRUCTION- AND MAINTENANCE MANUAL FOR ELECTROMAGNETIC AIR PUMP JDK-60, JDK-80, JDK-100, JDK-120
INSTRUCTION- AND MAINTENANCE MANUAL FOR ELECTROMAGNETIC AIR PUMP MODEL : JDK-60, JDK-80, JDK-100, JDK-120 - release 29.01.2014 - We thank you for purchasing our air pump. Prior to use, it is kindly requested
More informationKQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800
KQ Series Multistage Booster Pump System Installation Manual KQ200/400 KQ800 ISO 9001 Certified Description The KQ series booster pump is an all-in-one compact and reliable automatic multistage centrifugal
More informationElite Primer Baldor Series External Pond Pump
Elite Primer Baldor Series External Pond Pump ( 5250PPB21, 6440PPB23, 7550PPB26, 9600PPB28) Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS, READ AND FOLLOW ALL INSTRUCTIONS. SAVE THESE INSTRUCTIONS
More informationSECTION air supply system + WARNING: + NOTE: GENERAL DESCRIPTION COMPRESSED AIR RESERVOIRS / 1.
08-000.02/ 1 2011JA14 SECTION 08-000.02 GENERAL DESCRIPTION See Figure 1 for a schematic diagram of the. See the Nova LFS parts manual for a detailed schematic of the. The function of the vehicle s is
More informationwww. ElectricalPartManuals. com \/' INSTRUCTIONS WESTINGHOUSE RADIATORS DESCRIPTION '- INSTALLATION MAINTENANCE
FIG. 1. Westinghouse Single Radiators Mounted Perpendicular to the Wall of a Rectangular Tank on a 6,000 KVA Transformer THE WESTINGHOUSE RADIATOR is a highly efficient cooling unit which is designed for
More informationOperation Manual R205BV, R209BV
Operation Manual R205BV, R209BV 1 Safety Instruction The rotary evaporator is manufactured according to current methods and accepted safety regulations. However, risks still exist during the installation,
More informationInstallation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63
Installation and Maintenance Manual Forbes Marshall Tracer Line Trap Energy Conservation Environment Process Efficiency www.forbesmarshall.com Table of Contents 1. Preface...1 2. Important Safety Notes...1
More informationInstruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity
- Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity 100 PPD (2 kg/h) Chlorine or Sulfur Dioxide 250 & 500 PPD (5 & 10 kg/h) Chlorine or Sulfur Dioxide Anti-Siphon Ejector
More informationLONGONI ENGINEERING SRL
INDEX 1.1 Classification of heat exchanger and components 1.1.2 Type of heat exchanger and components 1.2 Purpose and scope of the manual 1.3 General instruction 1.4 Warning installation 1.5 Notes for
More informationArmstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual
Armstrong J Series, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual This bulletin should be used by experienced personnel as a guide to the installation
More informationBrown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS
SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett
More informationModulAir Air Dryer with External Purge Tank - Changeover from Bendix AD-IS for Peterbilt Installation. Air Dryer Mounting Bracket (Item 1)
Instruction Guide L31259 11/10 ModulAir Air Dryer with External Purge Tank - Changeover from Bendix AD-IS for Peterbilt Installation Air Dryer Mounting Bracket (Item 1) Tank Mounting Bracket (Item 19)
More information6. Cooling System XCITING 400i. This chapter covers the location and servicing of the cooling system components for the KYMCO XCITING 400i.
6. Cooling System XCITING 400i Cooling System This chapter covers the location and servicing of the cooling system components for the KYMCO XCITING 400i. Coolant... 6-3~6-11 Radiator... 6-12~6-23 Thermostat...
More informationBARRINGTON PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET K-4327
BARRINGTON PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET K-4327 BEFORE YOU BEGIN INSTALLER HAZARD NOTIFICATION WARNING: Risk of injury or water damage. Contents of vessel under pressure can cause severe
More informationOTO BONDER OWNER S MANUAL WITH CIRCULATING SYSTEM MACHINERY DIVISION - - L to R Unit Shown
GBAC RROTO OTO BONDER BONDER WITH CIRCULATING SYSTEM G B MACHINERY DIVISION OWNER S MANUAL L to R Unit Shown - - IMPORTANT FOREWORD 1) To ensure efficiency, the GBAC must be properly maintained. Carefully
More informationMODEL P. 2 ft. NPSH Cast Iron Bronze Fitted Low NPSH Centrifugal Pumps. BULLETIN 112 Revised 7/09. PH (Horizontal Flange Mounted)
SHIPPENSBURG PUMP CO., INC. P.O. BOX 279, SHIPPENSBURG, PA 17257 PHONE 717-532-7321 FAX 717-532-7704 WWW.SHIPCOPUMPS.COM BULLETIN 112 Revised 7/09 PH (Horizontal Flange Mounted) MODEL P 2 ft. NPSH Cast
More information! WARNING. Replacement Head Mechanism INSTRUCTION MANUAL MM-413F
INSTRUCTION MANUAL MM-413F Replacement Head Mechanism With Switch Assembly: 93-HD, 94-HD 93-M-HD, 94-M-HD 93-7B-HD, 94-7B-HD 93-7B-M-HD, 94-7B-M-HD Without Switch Assembly: 93-HDLS 94-HDLS Replacement
More informationPUGMILL/MIXER. Instruction Manual NVS-07
92895B PUGMILL/MIXER Instruction Manual NVS-07 Attention After carefully reading this manual, be sure to store it in a safe and convenient place for easy reference. Before using this unit, please read
More informationVacuum System Troubleshooting Author: Keith Webb, P.E. Application Engineering Manager
INTRODUCTION The science of creating vacuum is often misunderstood and when the desired vacuum condition is not being achieved in a manufacturing setting this usually means production comes to a halt and
More informationInstallation, Operation and Maintenance Instructions for PlantPac Steam Plate Heat Exchanger Package
OM014 Installation, Operation and Maintenance Instructions for PlantPac Steam Plate Heat Exchanger Package The operating and maintenance instructions contained within this package are for PlantPac packaged
More informationContents. 11. Preamble. 12. For the safe use. 13. Appearance. 14. Connecting the sources of electricity. 15. Caution for use before the operation.
PORTABLE DUST COLLECTOR FOR GENERAL PURPOSE USE OPERATING MANUAL (DUCLEAN) Model : SC Series Head office / Factory 148-90 Seowoon-Dong, Gyeyang-Gu, Incheon, Korea. TEL: 82-32-555-1661 FAX: 82-32-549-8644
More informationRefrigerated Compressed Air Dryer
Manual Instruction for Refrigerated Compressed Air Dryer Warning: Place the dryer machine horizontal. Never upside down Dino-power Industry & Trade Co., Ltd www.aircompressorschina.com Dino-power 1 PREPARED
More informationSMF PUMP OWNER S MANUAL
SMF PUMP OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING: Before installing this product, read and follow all warning notices and instructions
More informationINSTRUCTION MANUAL CLEAN BELLOWS TYPE INDUSTRIAL ROBOT SPECIFICATIONS. Notice
0 TH Series INSTRUCTION MANUAL CLEAN BELLOWS TYPE INDUSTRIAL ROBOT SPECIFICATIONS Notice 1. Make sure that this instruction manual is delivered to the final user of Toshiba Machine s industrial robot.
More informationCHAMPION PUMP OWNER S MANUAL
CHAMPION PUMP OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING: Before installing this product, read and follow all warning notices and instructions
More informationBall Float Steam Trap with Integral Spiratec Sensor and Flanged Connections
Page 1 of TI-P615-03 ST Issue IFT57 SG Iron ISO 9001 Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections Cert. No. LRQ 0963008 IFT57H DN0 (horizontal shown) DN15 (vertical shown)
More informationOWNERS GUIDE TO INSTALLATION AND OPERATION
OWNERS GUIDE TO INSTALLATION AND OPERATION SPM SERIES HIGH POWER CENTRIFUGALS READ THESE INSTRUCTIONS CAREFULLY Read these installation instructions in detail before installing your pump. Be sure to check
More informationOWNERS INSTRUCTION MANUAL FOR FIXED INSTALLATION COMMERCIAL AND RESIDENTIAL EVAPORATIVE AIR CONDITIONERS
R O O F T O P N A T U R A L A I R C O N D I T I O N E R S OWNERS INSTRUCTION MANUAL FOR FIXED INSTALLATION COMMERCIAL AND RESIDENTIAL EVAPORATIVE AIR CONDITIONERS How to Operate Using Your Air Conditioner
More informationWATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00
I&M NUMBER: 316-42-8-1 Page: 1 _ Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to
More informationClearFire Economizer Model ECF Integral or External. Addendum to manuals CFH and CFV
ClearFire Economizer Model ECF Integral or External Addendum to manuals 750-295 CFH and 750-269 CFV CB-8466 08/2011 1-GENERAL The Model ECF economizer is a stainless steel coil tube arrangement using
More informationBMW E36 Thermostat Removal And Coolant Flush
BMW E36 Thermostat Removal And Coolant Flush Disclaimer: The cooling system is critical to the proper operation of your car. Failure to properly install all of the components of the cooling system could
More informationSeries 1140 and 1141 Temperature Regulators
Hoffman Specialty Installation & Maintenance Instructions HS-504(E) Series 1140 and 1141 Temperature Regulators! CAUTION FOLLOW ALL INSTALLATION AND OPERATING INSTRUCTIONS. TURN OFF WATER OR STEAM BEFORE
More informationNanoprotech Italia
H2OFF Perfect protection from moisture and corrosion in hostile environments. H2OFF Electric H2OFF Anticorrosion How it works The nanomolecules of the product can penetrate into the smallest micro cavities
More informationECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL
ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING: Before installing this product, read and follow all
More informationFLUID POWER ENERGY, INC. W229 N591 Foster Court Waukesha, WI THERMOSTATIC VALVES. Instruction and Application Guidelines
THERMOSTATIC VALVES Instruction and Application Guidelines Your FPE Thermostatic Valve has been manufactured with extreme care and tested to insure that it had no detectable defects at the time it left
More informationINSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS JH-B SERIES JH5RL-B JH5RH-B JH7RH-B JH7.
INSTRUCTION MANUAL Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS JH-B SERIES JH5RL-B JH5RH-B JH3-B JH7RL-B JH7RM-B JH7RH-B JH7.2R-B JH8R-B JH7.5R-B Manufacturer 881
More informationWATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00
I&M NUMBER: 316-42-2-1 Page: 1 Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to elements
More informationA/C-HEATER SYSTEM - MANUAL
A/C-HEATER SYSTEM - MANUAL 1986 Isuzu Trooper II 1986 A/C-HEATER SYSTEM Isuzu A/C-Heater Systems - Manual P UP, Trooper II * PLEASE READ THIS FIRST * CAUTION: When discharging air conditioning system,
More informationTrouble Shooting Guide PWA, 3-phase (D10571)
Trouble Shooting Guide PWA, 3-phase (D10571) Trouble Shooting Guide Problem Possible Cause Possible Remedy Unit does not start Unit does not cool No power to unit, breaker tripped Low voltage Loose wire
More informationINSTRUCTION MANUAL FOR OIL BURNER MODELS
INSTRUCTION MANUAL FOR OIL BURNER MODELS X500-2 Low voltage 12v dc Brushed motor E90-803-001-005-01 Rev 4-1 - Contents Technical specifications Technical data...3 Working field...3 Dimensions...4 Head
More informationMaintenance 50 Serie CAUTION. Before resetting your electronic card that displays an error code. OVERHEAT MESSAGE
29-10-2013 CAUTION Before resetting your electronic card that displays an error code. OVERHEAT MESSAGE Service the stove COMPLETELY as described in this manual. Check the chimney pipe. BLOCKED FLUE MESSAGE
More informationSemi-Automatic Suction Screen Filters 3"-4 Angle. Service & Maintenance Manual
Semi-Automatic Suction Screen Filters 3"-4 Angle Service & Maintenance Manual Safety Instructions Prior to installation or handling of the filter, read the Installation and Operation instructions carefully.
More informationTOWEL WARMERS ARE HEAVY! WE RECOMMEND THAT TWO PEOPLE INSTALL THE TOWEL WARMER!
1. Please follow instructions carefully to ensure that the towel warmer is properly attached to the wall or floor. FAILURE TO FOLLOW THESE STEPS COULD RESULT IN PROBLEMS. 2. Do not use an abrasive or chlorine-based
More informationFAN ENGINEERING. Sealing of Fan Housings
FAN ENGINEERING Information and Recommendations for the Engineer FE-700 Sealing of Fan Housings Introduction A variety of options are offered by fan manufacturers to seal fan housings. Sealing the housing
More informationService Instructions. for the MELAG Autoclaves. MELAtronic 23. Technische Änderungen vorbehalten
Service Instructions for the MELAG Autoclaves MELAtronic 23 Technische Änderungen vorbehalten Functional reliability and retention of value of the unit depend on: - The proper preparation of the objects
More informationOperating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage
Model: 1090 1 Safety instructions Float-Controlled Condensate Trap, PN 16 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination
More informationThere are a few factors critical in the operation of a grease interceptor, which are: Design, Sizing, Proper installation and maintenance.
TEL: 773-341-3030 FAX: 773-341-3046 TOLL FREE: 1-800-465-2736 WEBSITE: www.mifab.com Grease Interceptors Description of Operation: There are a few factors critical in the operation of a grease interceptor,
More informationINSTALLATION INSTRUCTIONS
2008 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CH33 Series Units EVAPORATOR COILS 505,264M (65484504) 05/08 Supersedes 10/07 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE
More informationInstruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System
Effective: 5/13/15 Supersedes: New IS-AM09-601 Instruction Sheet Point of Use Hot Water Recirculation System THANK YOU for purchasing a new Aquamotion Hot System! For optimum reliability and performance
More informationINSTRUCTION MANUAL FOR OIL BURNER MODELS
INSTRUCTION MANUAL FOR OIL BURNER MODELS X500 Bio B10 E90-803-001-001-00 Rev 7-1 - Contents Technical specifications Technical data... 3 Working field... 3 Dimensions... 4 Head and electrode settings...
More informationGeneral Maintenance and Operating Instructions for Heat Exchangers
General Maintenance and Operating Instructions for Heat Exchangers Preamble Due to the diversity of operating conditions and the necessity for transparency and clarity of presentation, the maintenance
More information6. COOLING SYSTEM 6-0 COOLING SYSTEM MXU 500
6 COOLING SYSTEM SYSTEM FLOW PATTERN----------------------------------------------- 6-1 SERVICE INFORMATION------------------------------------------------ 6-2 TROUBLESHOOTING-----------------------------------------------------
More informationOHM N PREPARATIONS & SUPPORT FOR A WATERTUBE BOILER Fax: P.O. Box 96. Russell, IL
D E S C A L I N G OHM N S E R V I C E S PREPARATIONS & SUPPORT FOR A WATERTUBE BOILER 1-800-228-6462 Fax: 1-847-838-2226 P.O. Box 96. Russell, IL 60075 WWW.OHMANDESCALING.COM 1 OHMAN CIRCULATION DIAGRAM
More informationOperating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use
1 Safety instructions 1.1 Proper use Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN 100 Any improper use, intervention in the design and deviation from the design data automatically
More informationSteam Condensing Heat Exchanger SR-3 / SR-8
172-65207M-03 (SR-3/SR-8) 23 April 2014 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Steam Condensing Heat Exchanger SR-3 / SR-8 Copyright 2014 by TLV CO.,
More informationINSTALLATION INSTRUCTIONS CARE AND MAINTENANCE
INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE Heritage VorMax Right Height Elongated 2-piece Toilet Model 205AA104 Thank you for selecting American Standard - the benchmark of fine quality for over 100
More informationFAMSUN SDZB3000 Zoned Belt Dryer. Quick Manual
FAMSUN SDZB3000 Zoned Belt Dryer Quick Manual For operation and maintenance Has no legal effect Please refer to the product instruction for more information Catalog: 1.Maintenance of the air duct system
More informationTITAN FLOW CONTROL, INC.
PREFACE: TITAN FLOW This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI) Suction Diffusers. To ensure efficient and safe operation
More informationEYS SEPARATOR EYS 01 G. USER MANUAL for EYS SCREW-PRESS SEPARATOR MODEL EYS 01 G. User Manual for EYS 01G Screw-Press Separator
USER MANUAL for EYS SCREW-PRESS SEPARATOR MODEL EYS 01 G User Manual for EYS 01G Screw-Press Separator Table of Contents Page 1. Introduction 2 2. General Safety Instructions 3 3. Installation 5 4. Start-up
More informationKallista Bath Flip Drain
P21586 Page 1 of 7 THANK YOU FOR CHOOSING KALLISTA We appreciate your commitment to Kallista quality products. Please take a moment to review this manual before you install your Kallista product. If you
More informationCOLMAC COIL. Installation, Operation, and Maintenance ENG Rev A. Air Cooled Fluid Coolers. Contents. When you want Quality, specify COLMAC!
COIL Manufacturing Inc. When you want Quality, specify COLMAC! Installation, Operation, and Maintenance ENG00018621 Rev A Air Cooled Fluid Coolers Contents 1. SAFETY INSTRUCTIONS... 1 2. MODEL NOMECLATURE...
More informationHORIZONTAL MULTISTAGE CENTRIFUGAL PUMP
HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP WWPPCHLFT260 Instructions WWPPCHLFT260_Horizontal Multistage Centrifugal Pump_IB.indd 1 READ THIS MANUAL CAREFULL BEFORE INSTALL, START THE PUMP 1. Suction 2. Plug
More informationIndustrial Filters Replacement Procedure
FGD FGE FGET FGG Vessel Series Vessel Series Vessel Series Vessel Series p. 537 p. 538 p. 540 p. 543 FGA FGB FGC FGF Vessel Series Vessel Series Vessel Series Bag Filter p. 545 p. 549 p. 553 p. 555 FGH
More informationInstallation, Operation and Maintenance Manual for B&G U Series Heat Exchangers Removable Bundle Design BELL & GOSSETT.
BELL & GOSSETT SERVICE MANUAL SU/DSU, WU/DWU, and HTWU/DHTWU Series HT-50B-SM TCS/DTCS and TCW/DTCW Series Installation, Operation and Maintenance Manual for B&G U Series Heat Exchangers Removable Bundle
More informationVacmobile 20/2. Instruction manual OPERATION & SERVICE
This instruction manual provides general instructions for the Vacmobile 20/2 vacuum system. This machine may use either the Becker U4.20 or the PVR EM 20/B vacuum pump. Service information specific to
More informationOperation and Maintenance Manual Sondex All-Welded Heat Exchangers (SAW)
Operation and Maintenance Manual Sondex All-Welded Heat Exchangers (SAW) The contents of this publication are based on the latest information available and the materials that are used at the time of printing.
More informationFrost Checklist and Troubleshooting Guide for NDA1402 & NEA1402
Frost Checklist and Troubleshooting Guide for NDA1402 & NEA1402 REFRIGERATOR BULLETIN R82-7A NOVEMBER 2007 USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 574-294-2511
More informationSECTION AIR HANDLING UNIT
SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR
More informationInstallation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers
OM010 Installation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers The operating and maintenance instructions contained within this package are for ThermaFlex gasketed
More information215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions
215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions Lanair Products LLC 4109 Capital Circle Janesville, Wisconsin 53546 1-888-370-6531 www.lanair.com BEFORE YOU BEGIN INSTALLATION...
More informationWATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2
I&M NUMBER: 316-42-15-1 Page: 1 _ Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to
More informationOWNER S. m a n u a l C P L S E R I E S
OWNER S m a n u a l C P L S E R I E S CONTENTS 1 2 Introduction 3 Wall Control Functions 7 Drain Valve & Bleed System 8 Maintenance 10 Troubleshooting INTRODUCTION 2 Congratulations on choosing a new cooler
More informationUSER'S INFORMATION MANUAL
USER'S INFORMATION MANUAL SERIES DV GAS FIRED HOT WATER HEATING BOILER WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal
More informationECOPLUS MAG DRIVE UTILITY PUMP INSTRUCTIONS
ECOPLUS MAG DRIVE UTILITY PUMP INSTRUCTIONS 250 GPH 350 GPH 500 GPH 700 GPH 900 GPH Before operating this appliance please read this instruction manual carefully and keep it stored in safe place for future
More informationREFRIGERANT ON-VEHICLE INSPECTION AC 14
14 REFRIGERANT ON-VEHICLE INSPECTION 1. INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET (a) This is a method to specify trouble areas by using a manifold gauge set. Read the manifold gauge pressure
More informationINSTALLATION INSTRUCTIONS
,t_2007 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CH33 Series Units EVAPORATOR 505,264M (65484504) 10/07 Supersedes 09/06 COILS n _putech blications ical Litho U.S.A. RETAIN THESE
More informationSERVICE MANUAL. For Service & Parts please call APK THERMAL at or SAFETY INSTRUCTION
SERVICE MANUAL Installation, Operation and Maintenance Manual for Standrd Pre-Engineered Shell & Tube Models BCF, HCF, HFF, SSCF & SX2000 Fixed Tube Sheet Heat Exchangers For Service & Parts please call
More informationGMP compliant cleaning in the Pharmaceutical Industry. Andreas Trochsler 06. November 2012
GMP compliant cleaning in the Pharmaceutical Industry Andreas Trochsler 06. November 2012 Topics Why GMP Cleaning? Prevention of Cross Contamination in Automated GMP Washer About Belimed 2 B-SAG November
More informationBall Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass
Product of Quality Best Performance Ball Float Controlled Steam Traps Auto Drain Traps Float Valve Air Vent Valves Feed Control Valve Drain Control Valve Thermo Dynamic(TD) Trap Safety Valve Condensate
More information