Air cooler T 28-1/7
|
|
- Cynthia York
- 5 years ago
- Views:
Transcription
1 Air cooler Structure Equipped with feed water heater (Horizontal-type) 6 Remark): There are 2 types of air cooler that are equipped with and without feed water heater. Tools : (The construction varies depending on extracting 1 Extracting tool Components: 1 Roller plate Rail Eye bolts a No. Name of article Check item 1 Casing Take care about high temp. 2,2a Element Take care about broken tube, salting, sea water flow & outlet temp. 3 Header (gate side) For A/C use 4 Header Coated inside to prevent damage. 5 Flange 6 O-ring Replace by a new one. 9 Gasket Ditto 12 Header (gate side) For feed water heater 13 Header 14 Flange 15 O-ring Replace by a new one. 16 Gasket Ditto 17 Gasket Ditto 18 Gasket Ditto 19 Side plate 20 Eye plate T 28-1/7
2 1-1 Air cooler list No. ENG-NO Cyl. Ship Air Cooler Eng.Type Ship Yard No No. Manufacturer Type No. Heater RTA84T IHI Kure 3030 Kawasaki Heavy Industries SGHV740S-B1 4J368-C1,C2 SGHV740S-B1 4J368-H1,H2 Co., RTA84T IHI Kure 3049 do SGHV740S-B RTA84T IHI Kure 3053 Suction Gas Engine Mfg. SWPX-193/R152, 94-A561,A562 SHL6-102/R H031,H032 Co., SWPX-365/R152/4 94-A563,A RTA84T IHI Kure 3069 do SWPX-304F/R220, 95-A617,A618 SHL6-175/R H010,H011 SWPX-802/R220/4 95-A629,A RTA84T SHI do SWPX-521/R150/ A615,97-A616 Yokosuka RTA84T IHI Kure 3093 do do 98-A499,98-A RTA84T IHI Kure 3101 do SWPX-1181F/R220/4 98-A045,98-A046 SHL6-97/R220/4 98-H008,H RTA84T IHI Kure 3102 do do 98-A136,98-A137 SHL6-97/R220/4 98-H015,H RTA84T IHI Kure 3105 do do 98-A300,98-A301 SHL6-97/R220/4 98-H020,H RTA84T IHI Kure 3104 do SWPX-845/R A621,98-A622 SHL6-137/R H043,H RTA84T IHI Kure 3106 do SWPX-1181F/R220/4 99-A091,99-A092 SHL6-125/R H002,H RTA84T IHI Kure 3109 do CH6W-633/R220/2 99-A186,99-A187 SHL6-129/R H008,H RTA84T IHI Kure 3110 do do 99-A275,99-A276 SHL6-129/R H013,H RTA84T IHI Kure 3119 do CH6W-949F/R220/4 99-A396,99-A397 SHL6-135/R H019,H RTA84T IHI Kure 3122 do do 99-A479,99-A480 SHL6-135/R H021,H RTA84T IHI Kure 3125 do CH6F-1284F/R220B/4 00-A212, RTA84T IHI Kure 3126 do do 00-A318, RTA84T IHI Kure 3124 do CH6W-949F/R220/4 00-A123,124 SHL6-135/R H001,H RTA84T IHI Kure 3127 do CH6F-1284F/R220B/4 00-A410, RTA84T IHI Kure 3128 do do 01-A020, RTA84T IHI Kure 3154 do CH6F-1352F/R220B/4 SHL6-150/R220B/6 01-A122, H004,H RTA84T NKK 222 do CH6F-1589F/R220B/4 01-A231,01-A RTA84T NKK 225 do do 01-A480,01-A RTA84T IHI Kure 3159 do do 01-A446,01-A RTA84T IHI Kure 3160 do CH6F-1015/R220B/4 02-A083,A RTA84T IHI MU do CH6F-1431F/R220B/4 02-A241,A Kure 84T 28-2/7
3 1-2 Outline of structure 2. Check item 2-1 Periodic checks At time of engine patrol The feature of air cooler for RTA84T type engine is as follows. Flow direction of scavenging air: Air passage in horizontal (left and right) direction (Vertical-type air cooler) Less channeling in tubes even in small quantity of water Feed water heater: With or without heater Main engine can be run without supply of feed water Cooling medium: Fresh water or seawater In case of seawater, limits on minimum flow and maximum outlet temperature due to salting 1) Check the jointing face of casing (inlet side) and air-duct for leakage of scavenging air. (Caution: Be cautions about the scavenging temperature that normally it reaches higher than 140 C.) Measures: Tighten the bolts. Change packing during repair at the dock. 2) Ensure that a small amount of seawater (fresh water) flows all the time from the air vent. 3) Check the scavenging differential pressure before and after air cooler (the degree of element contamination). 4) Check the gasket and connecting pipe flange in the cooling water chest for leakage of seawater (fresh water). 5) Check the relief valve of feed water heater. 6) If drain from the air duct increase suddenly, the tube of air cooler is in danger of being broken. 84T 28-3/7
4 2-2 Cautions in operation 1) Take care about the followings so as to avoid scales accumulation in the tubes of air cooler. Kinds of scale Soft scale: Deposits of calcium carbonate (CaCO3) and magnesium hydroxide (Mg(OH)2 ) of seawater. Such deposit is not adhering usually to tube walls, but once dried, adheres to them and difficult to remove. (The wear and loss of anti-corrosion zinc causes similar phenomenon with the tubes.) Hard scale: The calcium sulfate (CaSO4) in seawater deposits and adheres to tube walls. Under a certain temperature continue, the tubes get blocked in a short time. So take care in controlling the temperature of cooling seawater. It is difficult to remove them chemically and/or mechanically. 2) Never use the feed water heater at the pressure exceeding maximum working pressure. 3) When seawater is leaking from a broken tube, provide blind plugs in the broken tube, as soon as possible. At the same time, check inside the scavenging space, then remove salt, and clean them with fresh water. 4) Control the air temperature of air cooler outlet by following procedure. Fully open the seawater outlet valve of air cooler. Fully close the seawater by-pass valve of air cooler. Adjust the air outlet temperature by control valve for circulating valve of seawater outlet. 5) Carry out the air vent for seawater line of air cooler at delivery from the port and at checking of M0 system, in order to prevent remaining the air in these lines. 6) Take countermeasures of corrosion at cooling seawater side. (Check the conditions of consumable Zn-plate etc. Correctly operate the MGPS, Fe-ion generator and supply unit of FeSO4 for countermeasure of corrosion at cooling seawater side. 7) Always confirm the tendency of differential pressure between air cooler inlet air pressure to outlet one, which is measured by manometer, in order to prevent contamination and blockage of cooler airside. 84T 28-4/7
5 2-3 Maintenance at dock 2-4 Investigation of air cooler renewal Check the protective metal: Every 3 ~ 6 months Inspection of painting / coating : 1 time / year 8) Check the protective metal at regular intervals, and renew it if necessary. 9) Take care not to damage rust-preventive coating (neoprene, hyperone, tar-epoxy, etc.) of the inner face of header. And any damage is discovered, repair it without delay. 10) When stopping the engine for a long periods, drain cooling seawater (include fresh water) inside air cooler. 1) As standard at the repair-dock, also considering the maintenance results of the air-coolers, to be unloaded this air-cooler and carried out overhauling and cleaning. At this chance, carry out the cleaning / inspection of both cooling water side and air side, also pressure test the leakage of cooling water side. 2) In the case that the erosion of cavitations etc. was discovered on the inlet side of cooling pipe with the inspection of the air cooler, insert the insertion tube (in case of round tube) in order to prevent the erosion 1) Grasp the condition of air cooler by periodic maintenance / inspection. 2) Make a proper maintenance plan according to the above conditions of the air cooler. 3) In the case that the operation point is not able to obtain the cooling ability of requiring in a short time in spite of after maintenance, consider renewal of the air cooler. Confirm the specification / capacity of the air cooler, and grasp the relation between the blockage rate (number) of tube and cooling ability. 3. Overhaul / reassembly 2) Retightening the bolts when scavenging air leakage happens. Just after overhaul and reassembly, air leak used to occur. 3) Replace the gasket and O-ring by new ones when the header is overhauled. And tighten the bolt clockwise (in the order of 12:00-6:00-3:00-9:00 of clock) 4) Ensure that there are no paint and oil sticking to the surface of protective metal and threads. 84T 28-5/7
6 3-1 Cleaning on air side Judging criterion for cleaning; To be cleaned before the maximum differential pressure reaches 300mm Aq. Cleaning method: 2)Cleaning by compressed air 3)Cleaning by steam Remove oil contaminated stuff with steam (3 ~ 7 kg/cm², 150 C) 4)Chemical cleaning (consult with the cleaning maker.) When airside is washed by the chemical, the stain of the upper tube falls to the lower tube by an insufficient washing, then the stain accumulates, and sometimes causes the blockage in the airside. Never heat the cleaning agent higher than 75 C. The cleaning time differs depending on the type of cleaning agent and the condition of dirt. After cleaning is finished, wash the tubes with fresh water to neutralize them. Confirm that the airside is not choked. 3-2 Cleaning on water side From the viewpoint of which the cooling pipes are blocked with salt, periodically carry out the washing by the brush or chemistry. Cleaning method: 1) Cleaning with a brush Do cleaning with a nylon brush (tool), during wet condition of inside the tubes. 2) Chemical cleaning (cooling effect cannot recovered with a nylon brush cleaning.) Improper chemical cleaning causes damages to the tubes and the life of equipment to be shortened remarkably, consult with the cleaning agent supplier. It is advisable to fit a water chest to the air cooler and to circulate chemicals. The cleaning effect increases with the rising temperature, but the temperature must not exceed 75 C. From the viewpoint of which the cooling pipes are corroded and broken, the medicine density that uses it for the chemistry washing is lowest density which is written in the instruction manual of medicine maker. 84T 28-6/7
7 4. Failure sample 1) Deposit of salt inside the scavenging space due to broken holes of air cooler. 2) Blocked tubes due to salting. 3) Water and air leakage due to aging of o-rings and gaskets 5. Technical information Service information DUQ1-059E Preventing maintenance against clogging of scavenge air cooler 84T 28-7/7
Air cooler C 28-1/6. Tools : (The construction varies depending on extracting tool)
Air cooler 6606 1. Structure Horizontal-type Remark): There are 2 types of air cooler that are equipped with and without feed water heater. 6 Tools : (The construction varies depending on extracting tool)
More informationInstallation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers
Bulletin 1200/4 (Revised 5/12) Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers INNOVATORS IN HEAT TRANSFER I. INSTALLATION OF HEAT EXCHANGERS A. HEAT EXCHANGER SETTINGS 1)
More information4 route 147, C.P.33 Coaticook, Qc J1A 2S8
4 route 147, C.P.33 Coaticook, Qc J1A 2S8 TABLE OF CONTENTS INSTALLATION Nozzles p.3 Clearance for dismantling p.4 Foundations p.4 Foundation bolts p.5 Leveling p.5 Bolted joints p.5 Recommended bolt tightening
More informationInstallation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers
OM010 Installation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers The operating and maintenance instructions contained within this package are for ThermaFlex gasketed
More informationUSER'S INFORMATION MANUAL
USER'S INFORMATION MANUAL SERIES DV GAS FIRED HOT WATER HEATING BOILER WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal
More informationOperation and Maintenance Manual Sondex All-Welded Heat Exchangers (SAW)
Operation and Maintenance Manual Sondex All-Welded Heat Exchangers (SAW) The contents of this publication are based on the latest information available and the materials that are used at the time of printing.
More informationUSER'S INFORMATION MANUAL
USER'S INFORMATION MANUAL SERIES ODVB GAS FIRED HOT WATER HEATING BOILER WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal
More informationRycroft Supapac Plate Heat Exchangers
Rycroft Supapac Plate Heat Exchangers Installation Operation & Maintenance Manual Ormandy Rycroft Duncombe Road Bradford BD8 9TB England TEL +44 (0)1274 490911 FAX +44 (0)1274 498580 www.rycroft.com 1.
More informationSERVICE MANUAL. For Service & Parts please call APK THERMAL at or SAFETY INSTRUCTION
SERVICE MANUAL Installation, Operation and Maintenance Manual for Standrd Pre-Engineered Shell & Tube Models BCF, HCF, HFF, SSCF & SX2000 Fixed Tube Sheet Heat Exchangers For Service & Parts please call
More informationNiles Steel Tank Hot Water Generator Installation and Operation Manual
Niles Steel Tank Hot Water Generator Installation and Operation Manual Contents: Contents 1 Hazard definitions 1 1. General Information.... 2 Availability... 3 Optional Control Packages... 5 2. Installation....
More informationEvaporators. Direct Expansion Flooded Recirculated Over Feed
Evaporators Purpose: Liquid Refrigerant is Boiled from a Low Pressure Liquid to a Low Pressure Gas by Absorbing Heat from the Medium that is being Cooled Types: Direct Expansion Flooded Recirculated Over
More informationWe are helping power generation facilities advance toward the future.
We are helping power generation facilities advance toward the future. Hisaka has a wealth of know-how and experience in heat exchangers using seawater, such as central cooling systems for power stations,
More informationArmstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual
Armstrong J Series, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual This bulletin should be used by experienced personnel as a guide to the installation
More informationSECTION air supply system + WARNING: + NOTE: GENERAL DESCRIPTION COMPRESSED AIR RESERVOIRS / 1.
08-000.02/ 1 2011JA14 SECTION 08-000.02 GENERAL DESCRIPTION See Figure 1 for a schematic diagram of the. See the Nova LFS parts manual for a detailed schematic of the. The function of the vehicle s is
More informationOperation Manual R205BV, R209BV
Operation Manual R205BV, R209BV 1 Safety Instruction The rotary evaporator is manufactured according to current methods and accepted safety regulations. However, risks still exist during the installation,
More informationINSTALLATION & OPERATING INSTRUCTIONS
INSTALLATION & OPERATING INSTRUCTIONS WARNING RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A CIRCUIT PROTECTED BY A GROUND-FAULT CIRCUIT-INTERRUPTER. THE UNIT SHOULD BE INSTALLED BY A QUALIFIED SERVICE REPRESENTATIVE.
More informationCOOLING / HEATING COILS
COOLING / HEATING COILS GENERAL INSTALLATION OPERATION AND MAINTENANCE COIL TYPES CHILLED WATER / GLYCOL HOT WATER / GLYCOL DIRECT EXPANSION (EVAPORATIVE COOLING) STEAM DISTRIBUTING STANDARD STEAM Type
More informationSELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H
SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS HP Phase Medium Head High Head 3 1 BMLS 300 M BMLS 300 H 3 3 BMLS 300 M3 BMLS 300 H3 5 1 BMLS 500 M BMLS
More informationFLUID POWER ENERGY, INC. W229 N591 Foster Court Waukesha, WI THERMOSTATIC VALVES. Instruction and Application Guidelines
THERMOSTATIC VALVES Instruction and Application Guidelines Your FPE Thermostatic Valve has been manufactured with extreme care and tested to insure that it had no detectable defects at the time it left
More information!!! Sample Written Program For Your Company. For BOILER SAFETY. Provided By:!!!
Sample Written Program For Your Company For BOILER SAFETY Provided By: P.O. Box 2136 Slidell, LA 70458 Phone: 985-781-1444 Fax: 985-781-1446 Email: info@se-safety.com Purpose Boiler Safety Program The
More informationGeneral Maintenance and Operating Instructions for Heat Exchangers
General Maintenance and Operating Instructions for Heat Exchangers Preamble Due to the diversity of operating conditions and the necessity for transparency and clarity of presentation, the maintenance
More informationVacuum System Troubleshooting Author: Keith Webb, P.E. Application Engineering Manager
INTRODUCTION The science of creating vacuum is often misunderstood and when the desired vacuum condition is not being achieved in a manufacturing setting this usually means production comes to a halt and
More informationInstallation, Operation and Maintenance Instructions ThermaFlex Gasketed Plate Heat Exchanger OM010
Installation, Operation and Maintenance Instructions ThermaFlex Gasketed Plate Heat Exchanger OM010 Calorifiers Heat Exchangers Pressurisation Units Sales Tel: 01457 835700 Sales Fax: 01457 832700 E-mail:
More informationContents. 11. Preamble. 12. For the safe use. 13. Appearance. 14. Connecting the sources of electricity. 15. Caution for use before the operation.
PORTABLE DUST COLLECTOR FOR GENERAL PURPOSE USE OPERATING MANUAL (DUCLEAN) Model : SC Series Head office / Factory 148-90 Seowoon-Dong, Gyeyang-Gu, Incheon, Korea. TEL: 82-32-555-1661 FAX: 82-32-549-8644
More informationWATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00
I&M NUMBER: 316-42-5-1 Page: 1 Pre Installation Check to make sure that heater received is the same as that ordered. Watlow heaters are built to comply with UL and CSA dielectric requirements, it may be
More information6. COOLING SYSTEM 6-0 COOLING SYSTEM MXU 500
6 COOLING SYSTEM SYSTEM FLOW PATTERN----------------------------------------------- 6-1 SERVICE INFORMATION------------------------------------------------ 6-2 TROUBLESHOOTING-----------------------------------------------------
More informationElite Primer Baldor Series External Pond Pump
Elite Primer Baldor Series External Pond Pump ( 5250PPB21, 6440PPB23, 7550PPB26, 9600PPB28) Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS, READ AND FOLLOW ALL INSTRUCTIONS. SAVE THESE INSTRUCTIONS
More information6. Cooling System XCITING 400i. This chapter covers the location and servicing of the cooling system components for the KYMCO XCITING 400i.
6. Cooling System XCITING 400i Cooling System This chapter covers the location and servicing of the cooling system components for the KYMCO XCITING 400i. Coolant... 6-3~6-11 Radiator... 6-12~6-23 Thermostat...
More informationAC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions
AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY PUMPS WITH MOTORS 1. No assembly required. Unpack the pump and motor and examine for any
More informationMJC Cartridge Filter Unit Operation & Maintenance
1 of 19 Hodge Clemco Ltd MJC Cartridge Filter Unit Operation & Maintenance Owner s Manual Date of Issue: 19.07.04 TSSM536.1a Hodge Clemco Ltd Orgreave Drive Sheffield S13 9NR Tel: 0114 254 8811 Fax: 0114
More informationProblem Cause Remedial action. Gauge glass There was excess chemical dosage The normal ph recommended was 9.5 to See photo 3 & 4.
CASE STUDIES OF STEAM SYSTEM AUDIT IN SOME PLANTS By K.K.Parthiban, Venus Energy Audit System Introduction This article outlines the outcome of auditing of steam system conducted in process Industries.
More informationHYDRAULIC OIL COOLER. Installation, Operation & Maintenance Guide
HYDRAULIC OIL COOLER Installation, Operation & Maintenance Guide HYDR AULIC OIL C OOLER Installation, Operation & Maintenance Guide Contents Foreword 2 1. SAFETY 1.1 Hazards when handling the heat exchanger
More information02 COOLING SYSTEM 02 COOLING SYSTEM COOLING SYSTEM INDEX. 1. General Specifications... 65
REV. 02 / 01.11.13 COOLING SYSTEM INDE 1. General... 64 2. Specifications... 65 3. Structure and Operation... 65 3.1. Cooling System... 65 3.2. Radiator... 65 3.3. Water Pump... 65 3.4. Thermostat... 65
More informationFreezertech Horizontal Plate Freezers Engineered for capacity
Freezertech Horizontal Plate Freezers Engineered for capacity Horizontal Plate Freezers Freezertech horizontal plate freezers are world renowned for their strong, long lasting construction, with an ergonomic
More informationMODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS
MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS 1. FEATURES The Type N Trap range is particularly suitable for high pressure/high temperature trapping applications
More informationBall Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass
Product of Quality Best Performance Ball Float Controlled Steam Traps Auto Drain Traps Float Valve Air Vent Valves Feed Control Valve Drain Control Valve Thermo Dynamic(TD) Trap Safety Valve Condensate
More informationREG NO FM BS EN ISO HEADER TANK HEAT EXCHANGER. Installation, Operation & Maintenance Guide
REG NO FM 38224 BS EN ISO 9001-2008 HEADER TANK HEAT EXCHANGER Installation, Operation & Maintenance Guide Foreword Dear Customer, BOWMAN has been manufacturing high quality header tank heat exchangers
More informationFAN ENGINEERING. Sealing of Fan Housings
FAN ENGINEERING Information and Recommendations for the Engineer FE-700 Sealing of Fan Housings Introduction A variety of options are offered by fan manufacturers to seal fan housings. Sealing the housing
More informationCRISTAL Built-in Dish Sterilizer Instruction Manual
CRISTAL Built-in Dish Sterilizer Instruction Manual Model No.: D36DSS Version Number: 01 Revision Date: September 2014 Dear user: Thank you for your purchase of CRISTAL built-in dish sterilizer! Please
More informationINSTALLATION & OPERATION Rev 1.00A DISTRIBUTED EXCLUSIVELY BY CMA DISHMACHINES KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841
MODEL UC 60e INSTALLATION & OPERATION Rev 1.00A DISTRIBUTED EXCLUSIVELY BY CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854- 6417 FAX 714-895-2141 www.cmadishmachines.com TABLE
More informationAkva Lux VX District heating substation for indirect heating and domestic hot water systems
Akva Lux VX District heating substation for indirect heating and domestic hot water systems Akva Lux VX Table of Contents Akva Lux VX... 1 Table of Contents... 1 Safety notes... 2 Delivery... 2 Transport
More informationCOLMAC COIL. Installation, Operation, and Maintenance ENG Rev A. Air Cooled Fluid Coolers. Contents. When you want Quality, specify COLMAC!
COIL Manufacturing Inc. When you want Quality, specify COLMAC! Installation, Operation, and Maintenance ENG00018621 Rev A Air Cooled Fluid Coolers Contents 1. SAFETY INSTRUCTIONS... 1 2. MODEL NOMECLATURE...
More informationTYPE FSD KYOWA EXHAUST GAS SCRUBBER OPERATION MANUAL
1 TYPE FSD KYOWA EXHAUST GAS SCRUBBER OPERATION MANUAL THAI KYOWA KAKO CO.,LTD. WWW.KYOWA.CO.TH 2 CONTENTS 1.SPECIFICATIONS... 2 2.EXTERNAL VIEW.. 3 3.FUNCTION OF EACH SECTION 4 4.SAFETY CONTROL AND SAFETY
More informationKyung Dong Oil Boiler. Contents. 1. General Warnings Safety Warnings
Contents 1. General Warnings --------------------- 1 2. Safety Warnings ----------------------- 2 3. Parts and structure --------------------- 7 4. Safety Device ------------------------- 9 5. Checkups
More informationInstruction and Maintenance Manual. Spiral Heat Exchanger
Instruction and Maintenance Manual Spiral Heat Exchanger 1. Content Description... Section 2 Introduction... Section 3 Important safety Precautions... Section 4 Generally... Section 5 Correct Installation...
More informationCHAMPION PUMP OWNER S MANUAL
CHAMPION PUMP OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING: Before installing this product, read and follow all warning notices and instructions
More information9. Cooling Water System
9.1 Water quality The fresh water in the cooling water system of the engine must fulfil the following requirements: ph... Hardness... Chlorides... Sulphates... min. 6.5...8.5 max. 10 dh max. 80 mg/l max.
More informationINSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS
INDEECO Circulation Heaters are designed to provide years of trouble free operation if properly installed and maintained. Please read and follow these instructions for installing and maintaining the heater.
More informationINSTALLATION INSTRUCTIONS
2008 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CH33 Series Units EVAPORATOR COILS 505,264M (65484504) 05/08 Supersedes 10/07 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE
More informationSeries 1140 and 1141 Temperature Regulators
Hoffman Specialty Installation & Maintenance Instructions HS-504(E) Series 1140 and 1141 Temperature Regulators! CAUTION FOLLOW ALL INSTALLATION AND OPERATING INSTRUCTIONS. TURN OFF WATER OR STEAM BEFORE
More informationModulAir Air Dryer with External Purge Tank - Changeover from Bendix AD-IS for Peterbilt Installation. Air Dryer Mounting Bracket (Item 1)
Instruction Guide L31259 11/10 ModulAir Air Dryer with External Purge Tank - Changeover from Bendix AD-IS for Peterbilt Installation Air Dryer Mounting Bracket (Item 1) Tank Mounting Bracket (Item 19)
More informationSMF PUMP OWNER S MANUAL
SMF PUMP OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING: Before installing this product, read and follow all warning notices and instructions
More informationOperating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage
Model: 1090 1 Safety instructions Float-Controlled Condensate Trap, PN 16 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination
More informationInstruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity
- Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity 100 PPD (2 kg/h) Chlorine or Sulfur Dioxide 250 & 500 PPD (5 & 10 kg/h) Chlorine or Sulfur Dioxide Anti-Siphon Ejector
More informationINSTALLATION AND MANINTENANCE INSTRUCTIONS
INSTALLATION AND MANINTENANCE INSTRUCTIONS Appr. Nr. A 9503 T - 0085 AQ 0765 PEGASUS F2 T HIGH EFFICIENCY GAS-FIRED CAST-IRON BOILERS Models 51-68 - 85-102 2 Contents 1. General technical data 2. Dimensional
More informationINSTRUCTION- AND MAINTENANCE MANUAL FOR ELECTROMAGNETIC AIR PUMP JDK-60, JDK-80, JDK-100, JDK-120
INSTRUCTION- AND MAINTENANCE MANUAL FOR ELECTROMAGNETIC AIR PUMP MODEL : JDK-60, JDK-80, JDK-100, JDK-120 - release 29.01.2014 - We thank you for purchasing our air pump. Prior to use, it is kindly requested
More informationRefrigerated Compressed Air Dryer
Manual Instruction for Refrigerated Compressed Air Dryer Warning: Place the dryer machine horizontal. Never upside down Dino-power Industry & Trade Co., Ltd www.aircompressorschina.com Dino-power 1 PREPARED
More informationDaily maintenance and checks
5 Daily maintenance and checks This chapter explains about daily maintenance and checks. The information herein is very important towards keeping the equipment regularly in proper working order. 5-1 5.1
More informationECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL
ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING: Before installing this product, read and follow all
More informationSeries 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING
Series 47 and 247 Mechanical Water Feeders McDonnell & Miller Installation & Maintenance Instructions MM-316(C) Series 47-2 and 247-2 Combination Mechanical Water Feeder/Low Water Cut-Off Series 47 Water
More informationAir Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)
http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made
More informationContents. 11. Preamble. 12. For the safe use. 13. Appearance (Body). 4. Before connecting sources of electricity. 15. Points of warning and caution.
PORTABLE DUST COLLECTOR FOR GENERAL PURPOSE USE OPERATING MANUAL (DUCLEAN) Model : LC Series Head office / Factory 148-90 Seowoon-Dong, Gyeyang-Gu, Incheon, Korea. TEL: 82-32-555-1661 FAX: 82-32-549-8644
More informationThermostatic Concealed Shower Valve
Thermostatic Concealed Shower Valve Product may differ from image. Please retain this booklet for future aftercare reference Component Breakdown - Three Handle Valve Component breakdown Two Handle Valve
More informationChannel plates Heat is transferred from one medium to the other through the thin channel plates.
Description English Description Main components Frame plate Carrying bar Carries the channel plates and the pressure plate. Support column Tightening bolts Press the channel plates together. Bolt protection
More informationScale Stopper Plus Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com Scale Stopper Plus Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your
More informationFully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified
Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified Thank you for purchasing our fully-automatic gas-fired tankless water heater. Please completely read this Manual
More informationKQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800
KQ Series Multistage Booster Pump System Installation Manual KQ200/400 KQ800 ISO 9001 Certified Description The KQ series booster pump is an all-in-one compact and reliable automatic multistage centrifugal
More informationWATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00
I&M NUMBER: 316-42-8-1 Page: 1 _ Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to
More informationUSER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater
USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater Contents Section Page Major Components... 2 1 About Our Manual... 2 2 Refractory Handling...
More informationUser s Information Manual
User s Information Manual Gas-Fired Storage Water Heater, Tankless Water Heater, Heating Appliance, and Combination Appliance Models IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR
More informationTitle: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards
Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to define the general installation and minimum product
More informationDescription. Main components. Lifting eyes To used for lifting and transport securing. Carrying bar Carries the cassettes and the pressure plate.
Description English Description Main components Lifting eyes To used for lifting and transport securing Frame plate Carrying bar Carries the cassettes and the pressure plate. Support column Connections
More informationAir Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)
http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made
More informationINSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION
INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / 27-009, 27-010, 27-015, 27-020 IMPORTANT INFORMATION UNATHORIZED CHANGES OR ALTERATIONS TO ANY LINCOLN PORTABLE VACUUM SYSTEM WILL AUTOMATICALLY
More informationUSER MANUAL SPRAY GUN CLEANER - WATER BASED PAINTS UA400W CAUTION FOR WATER BORNE PAINTS ONLY
USER MANUAL SPRAY GUN CLEANER - WATER BASED PAINTS UA400W CAUTION FOR WATER BORNE PAINTS ONLY THIS UNIT IS NOT DESIGNED FOR USE WITH SOLVENT BASED PAINT UNI-RAM CORPORATION ONTARIO CANADA REV 2010-09 CONTENTS
More informationHYDRAULIC OIL COOLER Installation, Operation & Maintenance Guide
REG NO FM 38224 BS EN ISO 9001-2008 HYDRAULIC OIL COOLER Installation, Operation & Maintenance Guide Foreword Dear Customer, BOWMAN has been manufacturing high quality hydraulic oil coolers for over 60
More informationWATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00
I&M NUMBER: 316-42-2-1 Page: 1 Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to elements
More informationINSTRUCTION MANUAL UFO3-BN UFO3F-BN UFO3-CN FREE BALL-BUCKET STEAM TRAP UFO SERIES. Copyright (C) 2007 by TLV Co., Ltd. All rights reserved.
INSTRUCTION MANUAL FREE BALL-BUCKET STEAM TRAP UFO SERIES UFO3-BN UFO3F-BN UFO3-CN Copyright (C) 2007 by TLV Co., Ltd. All rights reserved. Introduction Before beginning installation or maintenance, please
More informationHRS Heat Exchangers Instruction Manual
HRS Heat Exchangers Instruction Manual Plate Heat Exchanger Ceteplate HRS032, HRS140, HRS150, HRS220 and HRS240m Information courtesy of Cetetherm Table of contents Table of contents Description... 1 Main
More information12 Impeller Replacement
128 12 Impeller Replacement InTRODuCTIOn Jabsco - The Original Impeller Jabsco flexible impellers can be fitted to most makes and models of bronze flexible impeller engine cooling, bilge, transfer and
More informationAldrich Blowdown Separators & Cooling Manifolds
Aldrich Blowdown Separators & Cooling Manifolds ASME Section VIII U Stamped & National Board Registered Construction: Aldrich blowdown separators are constructed of 3/8 thick carbon steel shell and 3/8
More informationGENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.
Fig. 2: Blower & Evaporator Unit Specifications 2004 HVAC SYSTEMS Manual HVAC System - Sorento GENERAL SPECIFICATIONS AIR CONDITIONER Fig. 1: Air Conditioner Specifications BLOWER AND EVAPORATOR UNIT HEATER
More informationRequest for daily care
Inkjet printer JV5 series Request for daily care Inkjet plotter is the precision machine that has highly delicate mechanism. Especially, little dust and paper powder may have effect on a head nozzle, and
More informationResidential Gas Hybrid Water Heater
Residential Gas Hybrid Water Heater USER S INFORMATION MANUAL WGRGH20NG75F / WGRGH20NG76F / WGRGH20NG100F WGRGHNG75F / WGRGHNG76F / WGRGHNG100F Models* *A suffix of LP denotes propane gas NOTICE: Westinghouse
More informationModel: 1100 Float-Controlled Condensate Trap, PN 25
1 Safety instructions Model: 1100 Float-Controlled Condensate Trap, PN 25 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination
More informationTECHNICAL MANUAL ASGX
TECHNICAL MANUAL ASGX MEDIUM/HIGH PRESSURE HOT WATER BOILER INDEX 1 TECHNICAL CHARACTERISTICS... 2 1.1 GENERAL... 2 1.2 TECHNICAL DATA... 2 2 ACCESSORIES... 3 2.1 PRESSURE... 3 Pressure gauge... 3 Operation
More informationECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL
ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING: Before installing this product, read and follow all warning
More informationSuperKlean Washdown Products
February 2012 DURAMIX 8000 INSTALLATION AND MAINTENANCE INSTRUCTIONS **DO NOT THROW AWAY AFTER INSTALLATION** **SAVE AND DISPLAY PROMINENTLY WHERE THIS EQUIPMENT IS USED** WARNING HIGH PRESSURE AND HOT
More informationOperating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use
1 Safety instructions 1.1 Proper use Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN 100 Any improper use, intervention in the design and deviation from the design data automatically
More informationPet. Easy Guide. VAX Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire, WR9 OQH, UK - website:
V-027P Rapide Pet User Guide 10/7/07 10:05 Page 14 EEC STATEMENT OF COMPLIANCE Manufacturer/EEC importer: VAX Limited, hereby on our own responsibility declare that the products V-027/V-027PT/V-027P/CCW-701
More informationUSER S INFORMATION MANUAL
USER S INFORMATION MANUAL HOT WATER HEATING BOILERS DOMESTIC WATER HEATERS 150,000-300,000 Btu/hr MODELS EB-EWU-02 IMPORTANT INSTALLER - AFFIX INSTALLATION MANUAL ADJACENT TO THE BOILER CONSUMER - RETAIN
More informationhp Dust Collector With Vacuum Attachment
Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate
More information1.0 CONDITIONS FOR CHILLED WATER SUPPLY (PRIMARY SIDE BY DHCS SUPPLIER)
GENERAL This document contains the basic technical information for Architectural, Civil & Structural and M&E Building Services as required by supplier to achieve optimum operation. The time frame required
More informationBioMaster 250/350/600 BioMaster Thermo 250/350/600
Downloaded from www.watergardeningdirect.com BioMaster 250/350/600 BioMaster Thermo 250/350/600 A BMR0003 B BMR0004 2 BioMaster 250/350/600, BioMaster Thermo 250/350/600 C D BMR0021 BMR0022 3 Downloaded
More information! WARNING. Replacement Head Mechanism INSTRUCTION MANUAL MM-413F
INSTRUCTION MANUAL MM-413F Replacement Head Mechanism With Switch Assembly: 93-HD, 94-HD 93-M-HD, 94-M-HD 93-7B-HD, 94-7B-HD 93-7B-M-HD, 94-7B-M-HD Without Switch Assembly: 93-HDLS 94-HDLS Replacement
More informationWET ALARM VALVE CPF FIRE V.A.U. 3 V.A.U. 4
WET ALARM VALVE CPF FIRE V.A.U. 3 V.A.U. 4 1922 ILLUSTRATED MANUAL OF INSTALLATION, MAINTENACE CPF INDUSTRIALE Srl VIA E.FERMI, 98 25064 GUSSAGO (BS) ITALIA TEL.+39 030 310461 FAX.+39 030 310465 WWW.CPFINDUSTRIALE.IT
More informationRequest for daily care
Inkjet printer Tx400-1800D series Request for daily care Inkjet printer is the precision machine that has highly delicate mechanism. Especially, little dust and lint may have effect on a head nozzle, and
More informationAXPR Wall Mounted Axial Panel Fans
Bulletin 78-January-03-06 AXPR Wall Mounted Axial Panel Fans INSTALLATION, OPERATION, AND MAINTENANCE MANUAL This publication contains the installation, operation and maintenance instructions for the AXPR
More informationInstallation and Operating Service Manual
Installation and Operating Service Manual SPRAY-TYPE DEAERATOR Bryan Steam LLC, 783 N. Chili Avenue, Peru, IN 46970, Phone 765.473.6651, Fax 765.473.3074 www.bryanboilers.com Form 2141 Revision Date 5/1/2015
More informationConversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler
Gas boiler UPON COMPLETION OF THE INSTALLATION THE INSTALLER MUST INSTRUCT THE OWNER AND OPERATOR ON THE FUNCTIONALITY AND THE PROPER OPERATION OF THE BOILER AND THE HEATING SYSTEM. INSTALLER MUST REVIEW
More information