SALES TRAINING HEAT RECOVERY SYSTEMS BLOWDOWN SEPARATORS & TANKS LIQUID SAMPLE COOLERS ORIFICE METERS

Size: px
Start display at page:

Download "SALES TRAINING HEAT RECOVERY SYSTEMS BLOWDOWN SEPARATORS & TANKS LIQUID SAMPLE COOLERS ORIFICE METERS"

Transcription

1 SALES TRAINING HEAT RECOVERY SYSTEMS BLOWDOWN SEPARATORS & TANKS LIQUID SAMPLE COOLERS ORIFICE METERS

2 COMPANY OVERVIEW Madden Manufacturing, Inc. in Elkhart, IN since 1952 Originally operating out of Chicago, all production operations now exist in Elkhart Elkhart Our Mission is to produce simple, rugged industrial quality pumps and steam system equipment that will provide excellent performance and value for our customers.

3 BOILER BLOWDOWN PRODUCTS Heat Recovery Systems 3 Styles with 28 Models HV, HC, and HX series Blowdown Tanks and Separators 6 models of tanks and 10 models of separators Sample Coolers 2 Types with 11 Models Orifice Meters: Blowdown flow control 8 models: 2 types OM250/650

4 FUNCTION OF MADDEN HEAT RECOVERY SYSTEMS Madden Heat Recovery Systems work on the flash steam principle. When hot boiler blowdown enters the HC or HV unit, it hits a baffle causing some of the water to turn to flash steam. This flash steam is then sent off to the DA to be reused. The remaining hot water is cooled to a safe temperature by the heat exchanger coil or tube bundle in the bottom of the unit. The cooled blowdown is then safely disposed and the resulting heated up cooling water is now boiler feed water supplied to the D/A tank.

5 HV SERIES 12 Models Blowdown capacity from 3,000-15,000 PPH Vertical Type requires less floor space No solids build up Recovers 90% of lost heat Reduces temperature of blowdown discharge to meet statute limits Pays for itself in a matter of weeks for some installations

6

7

8 HC Series 10 Models Blowdown capacity from 4,000-50,000 PPH Horizontal Type No solids build up Recovers 90% of lost heat Reduces temp of blowdown discharge to meet statue limits Pays for itself in a matter of weeks for some installations

9

10 HX SERIES 6 Variations Designed for blowdown flows up to 3,500 lbs. per hour from boilers up to 150 psi ASME 150 psi shell construction Inexpensive yet durable No Flash steam created Fresh make up water is the shell side counter flow cooling media Self Cleaning

11

12 ORIFICE METERS OM250 & OM650 Rated at 250 & 650 PSI Each model has four different plate sizes Plates with 17 different hole sizes Gives boiler operator precise repeatable control of the continuous blowdown flow rate Generally used on industrial boilers from 200 PPH up to over 100,000 PPH steam production Guaranteed for up to 10 years from cutting, wire drawing, or other distortion in the orifice plate

13

14 PLATE AND SELECTOR DISC

15 ORIFICE FLOW CHART EX.

16 BDHR/ORIFICE METER SIZING EXAMPLE Example: Customer has 5 boilers operating at 125 psi Each have 50,000 PPH capacity with a maximum steam load of 130,000 PPH for the system. Average continuous blowdown is 5% and sometimes they ll have a max of 10% continuous surface blowdown. They would also like orifice meters for this application. Question: Which HV/HC unit is most appropriate for this application?

17 EXAMPLE CONTINUED Process: To come up with this all you need to do is find the continuous surface blowdown in PPH. Sometimes this is a percentage of steam and other times the customer/engineer can tell you what average and maximum surface blowdown they are working with. Answer: So, by taking 10% of the maximum steam load of 130,000 PPH, we know that this application will have a max of 13,000 PPH of continuous surface blowdown. HC has a max capacity of 16,000 PPH and costs $21,850 HV150A/B has a max capacity of 15,000 PPH and costs $21,700/$23,500 (depending on coil choice).

18 Answer for the Orifice Meter: When it comes to the orifice meters requested, you need to focus on individual boiler blowdown. An orifice meter will be connected to the top blowdown line for each boiler. In this case we would take 10% of the 50,000 PPH capacity and quote an orifice meter that could handle the resulting potential of a 5,000 PPH blowdown maximum. So go to the charts and follow the 125 psi column down until you hit a number just above 5,000. This will be the plate size and orifice meter that you will need to quote. For this example it is an OM250-3A.

19 BLOWDOWN SEPARATORS Purpose: The purpose of a blowdown separator is to cool off the intermittent boiler blowdown flow so the waste water can be safely discharged into a public sewer system and so that the flash steam can be safely vented into the atmosphere. Function: High temperature and pressure blowdown water impacts the striking plate. Flash steam is created and the remaining 212 F hot water drains into the aftercooler. The Flash steam exits to the atmosphere through the vent connection. In the aftercooler the hot water is mixed with cooling water to instantaneously cool the blowdown to a safe temperature. A baffle is placed to assist the mixing of the two liquids. Both the blowdown and cooling water are then sent off to the public sewer. Aftercooler kit not shown

20

21 BD SEPARATOR SIZING EXAMPLE Example: Now for that same customer, let s say this is a completely new system for a food plant that is going in, and they had no equipment to begin with. Question: How do you size the blowdown separator they need? Process: To size a Madden blowdown separator you need to know the operating pressure and the blowdown line size. So, let s say this customer got back to you and let you know that the bottom blowdown line is 2.

22 Answer: We know that the operating pressure is 125 psi, so we will be staying in the top half of the chart. We know the bottom blowdown line is 2, you can see that you will quote a BD230E55. The aftercooler is easy to quote as it simply falls in line on our chart. The AC500 and AC105 regulating valve would be what was needed. The aftercooler lines up with the separator drain size and then the regulating valve lines up with the aftercooler cold water inlet size.

23 BLOWDOWN TANKS Cools via flash steam principle as well as convection cooling Designed to breakup the blowdown flow by impacting the high pressure hot water on the steel centrifugal impact plate Water droplets give up heat as flash steam is formed Steam is vented into the atmosphere Retained water remains until cooled to statute limits

24

25 TYPE 1 SAMPLE COOLERS Cooling Water Sample Miniature heat exchangers designed to reduce high temperature liquid samples to safe, usable temperatures for analysis Tubing: 316 Stainless Steel & Copper, Inconel is also available though not common Side shell pressure rating 150 psi Stainless Steel shell available for the type 1s Type 1 sample cooler models have all the piping connections for the sample and the cooling water on the threaded cap on the top of the sample cooler. All coils are 1/4 OD tubing, and all piping connections are 1/4 NPT. Cooling water enters on the left (right in this picture, all caps are labeled) and exits opposite on the right. Sample inlet connection is vertical on the top, and the cooled sample exits from the spout.

26 TYPE 2 SAMPLE COOLERS Miniature heat exchangers designed to reduce high temperature liquid samples to safe, usable temperatures for analysis Tubing: 316 Stainless Steel & Copper, Inconel is also available though not common Carbon Steel shell Side shell pressure rating 150 psi Type 2 sample coolers offer both 1/4 and 3/8 OD tubing coils. Sample connections are 1/4 NPTF and are made on the top plate. Cooling water connections are 3/8 NPTF located on both top and bottom plates. Cooling water Sample

27

28 SELLING MADDEN STEAM PRODUCTS All about the bottom line and time Our products save money And systems can be disassembled to replace worn out parts

29

30 QUESTIONS/DISCUSSION? OR CALL (574)

Centrifugal Blowdown Separators and Tanks

Centrifugal Blowdown Separators and Tanks Centrifugal Blowdown Separators and Tanks Function: Madden Blowdown separators are designed to immediately dispose of hot, high pressure boiler blowdown. When the hot, high pressure bottom blowdown from

More information

Aldrich Blowdown Separators & Cooling Manifolds

Aldrich Blowdown Separators & Cooling Manifolds Aldrich Blowdown Separators & Cooling Manifolds ASME Section VIII U Stamped & National Board Registered Construction: Aldrich blowdown separators are constructed of 3/8 thick carbon steel shell and 3/8

More information

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016 Boiler Condensate Return Basics Presented by Steve Connor February 24, 2016 What We Are Covering Today? Brief review of the total steam system Why a proper condensate return system is so important Condensate

More information

100 years of boiler technology leadership.

100 years of boiler technology leadership. 100 years of boiler technology leadership. TM A subsidiary of Burnham Holdings Compact Boiler Feed Systems Capacities from 20 to 80 boiler HP 15 through 150 PSI boilers The Bryan compact boiler feed system

More information

A M E M B E R O F T H E K E N D A L L G R O U P

A M E M B E R O F T H E K E N D A L L G R O U P A M E M B E R O F T H E K E N D A L L G R O U P Presented by: Dan Gallagher Energy Opportunities in a Steam System What makes up your Steam System Boiler Room Distribution System Mechanical Rooms Point

More information

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com Tray ST5 Pressurized and Atmospheric Deaerators Tray Type Deaerator Pressurized.005 cc/liter COUNTER FLOW TRAY design provides guaranteed removal of all dissolved oxygen in excess of.005 cc/liter from

More information

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series Pamphlet A2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment

More information

High Capacity Instantaneous Steam Fired Water Heater

High Capacity Instantaneous Steam Fired Water Heater MODEL F High Capacity Instantaneous Steam Fired Water Heater Features Compact High Capacity Design Packaged System Water heater is factory assembled on an all welded steel mounting frame to save time and

More information

Commercial Semi-Instantaneous Water Heaters

Commercial Semi-Instantaneous Water Heaters FEATURES HWI Models A. O. Smith s HWI models are available for operation with steam or boiler water as the energy source. They are factory assembled with components sized, piped and checked at the factory

More information

INSTALLATION, OPERATION

INSTALLATION, OPERATION OM No. E-SCSF-170111-1 INSTALLATION, OPERATION and MAINTENANCE MANUAL Thermodynamic Steam Trap MODEL: SC/SF MIYAWAKI INC. Osaka, Japan 2 SAFETY INSTRUCTION Prior to using the SC/SF steam trap, read this

More information

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM:

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM: BEST PRACTICE NO. 51 THE PRESSURIZED CONDENSATE RECOVERY SYSTEM: the solution to increasing a steam system s thermal cycle efficiency Pressurized condensate systems can provide plants with a minimum of

More information

Section H11 BLOWDOWN SEPARATORS CONTENTS FEATURES AND BENEFITS...H11-3 PRODUCT OFFERING...H11-3 SAMPLE SPECIFICATIONS...H11-11 ILLUSTRATIONS

Section H11 BLOWDOWN SEPARATORS CONTENTS FEATURES AND BENEFITS...H11-3 PRODUCT OFFERING...H11-3 SAMPLE SPECIFICATIONS...H11-11 ILLUSTRATIONS Section H BLOWDOWN SEPARATORS CONTENTS FEATURES AND BENEFITS...................................................H- PRODUCT OFFERING.......................................................H- SAMPLE SPECIFICATIONS...................................................H-

More information

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel: www.watsonmcdaniel.com 428 Jones Boulevard Limerick Airport Business Center Pottstown PA 19464 Tel: 610-495-5131 129 Return Introduction Return System Shown below is a simplified view of a steam system

More information

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime. Armstrong Mini Pump Bulletin AFH-223 The Armstrong mini pump trap is the smallest non-electric solution that can move condensate or other liuids from lower to higher points and from lower to higher pressures.

More information

UNFIRED STEAM GENERATORS STANDARD EQUIPMENT

UNFIRED STEAM GENERATORS STANDARD EQUIPMENT CEMLINE Unfired Steam Generators are designed to produce clean steam with steam or high temperature hot water as an energy source for use where there is a need to produce clean steam from boiler steam

More information

Flo-Rite-Temp Instantaneous Steam/Water Heater

Flo-Rite-Temp Instantaneous Steam/Water Heater Steam/Water Heaters Steam/water heaters are typically classified as instantaneous, semi-instantaneous and tank-type. Temperature control can be defined as either feed-forward or feedback. Feedback systems

More information

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents Hoffman Specialty Regulators Main Steam How to Select Steam Model Radiator Convector Unit Thermostatlic Number (Angle Type) (Bottom Inlet) Heater Mains Vent (only) Remarks 1A X Adjustable Orifice 70A X

More information

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series Pamphlet M2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment

More information

ClearFire Economizer Model ECF Integral or External. Addendum to manuals CFH and CFV

ClearFire Economizer Model ECF Integral or External. Addendum to manuals CFH and CFV ClearFire Economizer Model ECF Integral or External Addendum to manuals 750-295 CFH and 750-269 CFV CB-8466 08/2011 1-GENERAL The Model ECF economizer is a stainless steel coil tube arrangement using

More information

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series Pamphlet U2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment

More information

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water Packaged Instantaneous Domestic Hot Water Generator Energy Source: Shown with optional boiler water valve and electronic feed-forward control. Operates with low boiler water supply and return temperatures

More information

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133. Main Steam How to Select Steam For Steam Vent selection information, please refer to Selection Guidelines on page 133. Model Radiator Convector Unit Thermostatlic Number (Angle Type) (Bottom Inlet) Heater

More information

BASCO U-TUBE & TANK IMMERSION HEAT EXCHANGERS. ...world leaders in heat transfer technology

BASCO U-TUBE & TANK IMMERSION HEAT EXCHANGERS. ...world leaders in heat transfer technology BASCO U-TUBE & TANK IMMERSION HEAT EXCHANGERS...world leaders in heat transfer technology BW-533.indd 1 6/7/07 5:33:16 PM Standard Heat Exchanger Designs Deliver Cost Effective Performance To address the

More information

Flo-Rite-Temp Instantaneous Steam/Water Heater

Flo-Rite-Temp Instantaneous Steam/Water Heater Steam/Water Heaters Steam/water heaters are typically classified as instantaneous, semi-instantaneous and tank-type. Temperature control can be defined as either feed-forward or feedback. Feedback systems

More information

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107 TABLE OF CONTENTS FLOAT AND THERMOSTATIC SERIES PAGE How to Select All 107 C 14 H 8 I 12 X 14 Competitive Changeover 18 THERMOSTATIC 8C 22 9C 2 17C 20 Competitive Changeover 17C 24 Replacement Modules

More information

Steam Ancillary Equipment. Primary Steam System, Water Treatment and Auxiliary Steam System Equipment

Steam Ancillary Equipment. Primary Steam System, Water Treatment and Auxiliary Steam System Equipment Steam Ancillary Equipment Primary Steam System, Water Treatment and Auxiliary Steam System Equipment WITH ANCILLARY EQUIPMENT Steam Header with Accumulator Gas Train Assembly Single Point Gas Supply Trap

More information

TMCI Padovan Evaporators

TMCI Padovan Evaporators TMCI Padovan Evaporators Evaporators Our range includes 4 types of evaporators: Forced Circulation Falling Film Evaporators Plates Thin Film Concentration systems Evaporator choosing criteria: product

More information

In-Line Air Separators

In-Line Air Separators Air Elimination & Control In-Line Air Separators The AC models of air separators deliver all the quality and performance you expect from Taco products. They are built to last with shell, heads and ANSI

More information

Silhouette. Feedwater Heater. Boiler Feedwater

Silhouette. Feedwater Heater. Boiler Feedwater Roth Roth Low Low Silhouette Silhouette TRAY DEAERATORS Boiler Boiler Feedwater Feedwater Heater Heater Capacities Capacities to to 50,000 50,000 lb/hr lb/hr Model RDTV-150-5-1-2 vertical tray type deaerator

More information

SIOUX HYBRID WATER HEATER

SIOUX HYBRID WATER HEATER SIOUX Hybrid Water Heater for the Concrete Industry SIOUX HYBRID WATER HEATER Patent Pending Maximizing the Benefits of Coil and Direct-Fired Heating Technologies Higher Discharge Temperature True High-Efficiency

More information

Boiler Steam Supply Piping Basics November 18, ) Q: What kind of condensate traps should be used on vacuum condensate return systems?

Boiler Steam Supply Piping Basics November 18, ) Q: What kind of condensate traps should be used on vacuum condensate return systems? Boiler Steam Supply Piping Basics November 18, 2015 1) Q: What kind of condensate traps should be used on vacuum condensate return systems? A: What is often used in a vacuum system is a thermodynamic disc

More information

USG Series. Unfired Steam Generators Generate Clean Steam With Boiler Steam or High Temperature Hot Water as the Energy Source

USG Series. Unfired Steam Generators Generate Clean Steam With Boiler Steam or High Temperature Hot Water as the Energy Source USG Series Unfired Steam Generators Generate Clean Steam With Boiler Steam or High Temperature Hot Water as the Energy Source CEMLINE CORPORATION P.O. BOX 55 CHESWICK, PENNSYLVANIA 15024 Phone: (724) 274-5430

More information

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com Spray Flow II Pressurized and Atmospheric Deaerators.005 cc/liter Atmospheric Deaerator CONSTANT RECYCLING guarantees deaeration of all dissolved oxygen in excess of.005 cc/liter from 0% to 100% of deaerator

More information

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com Spray Flow II.00 cc/liter Atmospheric Deaerator Pressurized and Atmospheric Deaerators CONSTANT RECYCLING guarantees deaeration of all dissolved oxygen in excess of.00 cc/liter from 0% to 100% of deaerator

More information

Packaged Steam Fired Water Heater

Packaged Steam Fired Water Heater MODEL ST Packaged Steam Fired Water Heater Utilizes Steam To Heat Domestic Water, Semi-Instantaneous or Storage Type Heaters Features Reliable Packaged System Only high grade materials used in construction

More information

SB Series Brazed Plate Heat Exchanger Installation Manual

SB Series Brazed Plate Heat Exchanger Installation Manual SB Series Brazed Plate Heat Exchanger Installation Manual HOT COLD Exploded view of Schmidt SB Brazed Plate Heat Exchanger. WARNING Before proceeding with installation and operation read entire manual

More information

Blowdown Separator & Aftercoolers Installation, Operation, & Maintenance

Blowdown Separator & Aftercoolers Installation, Operation, & Maintenance Blowdown Separator & Aftercoolers Installation, Operation, & Maintenance 750-326 04/2010 Blowdown Separator & Aftercoolers Installation, Operation, & Maintenance INSTALLATION BLOWDOWN SEPARATOR Installation

More information

.03 ATMOSPHERIC DEAERATOR

.03 ATMOSPHERIC DEAERATOR .03 ATMOSPHERIC DEAERATOR SPECIFICATION SHEET NO. 3200 OCTOBER 1, 2007 GENERAL DESCRIPTION The Sellers atmospheric.03 deaerators condition make-up water and condensate returns to convert them into more

More information

Blowdown Separator & Aftercoolers

Blowdown Separator & Aftercoolers Blowdown Separator & Aftercoolers Installation, Operation, & Maintenance Thermaflo Engineering PO Box 473639, Charlotte, NC 28247 Blowdown Separator & Aftercoolers Installation, Operation, & Maintenance

More information

1. Know your process. The following guidelines will help you navigate what can be a challenging and time consuming task.

1. Know your process. The following guidelines will help you navigate what can be a challenging and time consuming task. Many processes today require an indirect method of heating, which implies the use of a heat transfer medium, instead of circulating the process directly into a heater. Thermal oil, water, glycol mixtures,

More information

Steam Systems 101. Understanding Your Energy Systems Better. May 5, 2016

Steam Systems 101. Understanding Your Energy Systems Better. May 5, 2016 Steam Systems 101 Understanding Your Energy Systems Better May 5, 2016 Introductions Background in Heating/Power plants associated with large industrial and central plants associated with campus distribution

More information

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3 Wide range of steam traps that provide consistent performance in less than perfect conditions Features 1 1 Thermostatic Traps Repairable Pressure assisted fail-open design Freeze proof Easy to check cyclic

More information

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS STEAM TRAPS Steam Traps Steam Trap Model * Sizes 3/4, 1, 1 1 /2, 2, 3, 4 Connections NPT, SW, FLG Body Material Carbon Steel or 316SS Options Live Orifice Air Vent PMO Max. Operating Pressure 450 PSIG

More information

Packaged Semi-Instantaneous Steam Fired Water Heater

Packaged Semi-Instantaneous Steam Fired Water Heater MODEL STX Packaged Semi-Instantaneous Steam Fired Water Heater Shell and Tube Style Heater Features Reliable Only high grade materials used in construction to ensure long operating life Heat exchange pressure

More information

Marine Heat Exchangers SALES SERVICE REPAIR

Marine Heat Exchangers SALES SERVICE REPAIR Marine Heat Exchangers SALES SERVICE REPAIR Heat Transfer Equipment THE BROADEST SELECTION AVAILABLE FOR GENERAL HEATING AND COOLING. PRODUC 104-32 Shell & Tube Heat Exchangers PRE-ENGINEERED FOR GENERAL

More information

Moss MOSS TRAY DEAERATOR ECONOMICAL INDUSTRIAL DEAERATOR SYSTEMS

Moss MOSS TRAY DEAERATOR ECONOMICAL INDUSTRIAL DEAERATOR SYSTEMS Moss MOSS TRAY DEAERATOR ECONOMICAL INDUSTRIAL DEAERATOR SYSTEMS MOSS TRAY DEAERATOR DESIGNS WHY DEAERATE? Removal of corrosive oxygen and carbon dioxide from boiler feedwater Reduction in the use of oxygen

More information

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to HOW TO ORDER page. PT5 Thermodynamic Steam Traps MATERIAL : No. PART MATERIAL QTY. (Nos.). BODY ASTM A743 Gr. CA 40 0 (Seat Hardened) (Cast Equiv. AISI 420) 2. DISC CAP ASTM A743 Gr. CA 40 0 (Cast Equiv. AISI 420) 3. DISC

More information

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER Compact Design High Recovery Energy Efficient Stainless Alloy Construction Factory Packaged Integral Safety System ASME Constructed & Stamped

More information

Deaerators for Industrial Applications

Deaerators for Industrial Applications Deaerators for Industrial Applications Combined Cycle Power Plant Deaera Deaerator - a device that is widely used for the removal of oxygen and other dissolved gases from the feedwater to steam-generating

More information

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS Inverted Float & Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS ABOUT US In 1916, the company, then known as the Sterling Engineering Company, began designing and manufacturing valves, traps, strainers

More information

Commercial Hot Water Maker

Commercial Hot Water Maker Boiler Mate Series Commercial Hot Water Maker Indirect-Fired Water Heaters Models WH-7C and WH-10C 1 INNOVATIVE DESIGN FOR REAL WORLD APPLICATIONS The Boiler Mate Series commercial Hot Water Maker design

More information

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass Product of Quality Best Performance Ball Float Controlled Steam Traps Auto Drain Traps Float Valve Air Vent Valves Feed Control Valve Drain Control Valve Thermo Dynamic(TD) Trap Safety Valve Condensate

More information

HEAT EXCHANGER FORMULAS & EXAMPLE

HEAT EXCHANGER FORMULAS & EXAMPLE Formulas for Heat Exchanger System using a Modulating Control Valve Definition of Terms and Units: E = Mean Heat Transfer Rate or Heat Load (Btu/hr) E D = Design Heat Load (Btu/hr) U = Overall Heat Transfer

More information

Documento Descargado desde:

Documento Descargado desde: Documento Descargado desde: WWW.VAPORISA.CL Pumping Traps Inside Advantages Mechanical condensate pumps operate with a spring-assisted float mechanism, which means the springs themselves are a major wear

More information

Technical Illustration of Condensate Formation

Technical Illustration of Condensate Formation Condensate Recovery As hot steam cools down inside a mill s pipes, the droplets of vapor turn into condensate water. If recycled, this condensate water can provide mills with an inexpensive source of clean

More information

Deaerator. Specifications

Deaerator. Specifications ESI, INC. OF TENNESSEE RENTAL EQUIPMENT Deaerator Description The deaerator, built in 1996, is a spray-type deaerating feedwater heater and storage tank with stainless steel internals. The deaerator is

More information

APPLICATIONS FOR HVAC SYSTEMS

APPLICATIONS FOR HVAC SYSTEMS H E A T E X C H A N G E R S BULLETIN NO. TIS-112A PLATE & FRAME HEAT EXCHANGERS APPLICATIONS FOR HVAC SYSTEMS THE heat transfer people H E A T E X C H A N G E R S 2 Highly Efficient Low Cost Expandable

More information

ANNEX 6. Refinery No. 1 New Area. Problems Existing in the Current Condensate Return System of the New Area of Refinery No.1

ANNEX 6. Refinery No. 1 New Area. Problems Existing in the Current Condensate Return System of the New Area of Refinery No.1 ANNEX 6 In FP the project was divided in two phases, but due to financial difficulties, Phase II is still not implemented. Below is what happened in Phase I of the Project, which will be replicated in

More information

IN THE PULP AND PAPER INDUSTRY

IN THE PULP AND PAPER INDUSTRY H E A T E X C H A N G E R S BULLETIN NO. TIS-105A PRIME SURFACE PLATE & FRAME ALL-WELDED PLATE IN THE PULP AND PAPER INDUSTRY THE heat transfer people H E A T E X C H A N G E R S 2 TRANTER BRINGS EFFICIENCY

More information

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM BEST PRACTICE NO. 30 WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM Air and noncondensable gases are one of the major problems in a steam system that can cause production

More information

Economical and simplified solutions that offer quality and optimum steam trap service.

Economical and simplified solutions that offer quality and optimum steam trap service. Economical and simplified solutions that offer quality and optimum steam trap service. It All Comes Down To Protection Regardless of the temperature and pressure characteristics of steam line drips or

More information

For an administrative fee of $9.97, you can get an un-locked, printable version of this book.

For an administrative fee of $9.97, you can get an un-locked, printable version of this book. The System Evaluation Manual and Chiller Evaluation Manual have been revised and combined into this new book; the Air Conditioning and Refrigeration System Evaluation Guide. For an administrative fee of

More information

FUEL-FIRED VERTICAL TUBELESS BOILERS

FUEL-FIRED VERTICAL TUBELESS BOILERS FUEL-FIRED VERTICAL TUBELESS BOILERS 4 60 P orizontal and Vertical Feedwater / Condensate Return Systems and Blow-down Tanks FULTON FUEL-FIRED VERTICAL TUBELESS BOILERS FULTON: AN INDUSTRY LEADER SINCE

More information

Cemline Steel Tanks. Carbon Steel, Stainless Steel, Galvanized Steel, Copper A.S.M.E. Code, Non-Code

Cemline Steel Tanks. Carbon Steel, Stainless Steel, Galvanized Steel, Copper A.S.M.E. Code, Non-Code Cemline Steel Tanks Carbon Steel, Stainless Steel, Galvanized Steel, Copper A.S.M.E. Code, Non-Code CEMLINE CORPORATION P.O. BOX 55 CHESWICK, PENNSYLVANIA 15024 Phone: (724) 274-5430 FAX: (724) 274-5448

More information

Series 300 VTB. Installation Instructions

Series 300 VTB. Installation Instructions Series 300 VTB Installation Instructions Sizes 7 12 16 20 30 HP #2 Fuel Oil Gas (500 to 2500 BTU) Gas Light Oil Combination High Pressure Steam Sizes 7 thru 16 HP (125 PSI) Sizes 20 and 30 HP (150 PSI)

More information

BOILER HOUSE PRODUCTS GMS

BOILER HOUSE PRODUCTS GMS GMS BOILER HOUSE PRODUCTS Contents Page 2 Introduction 3 Condensate Pumpsets 6 Blowdown Vessels 8 Boiler Feed Tanks Page 10 Chemical Dosing Pots 11 Vent Heads 11 De-Aerator Heads Introduction to Boiler

More information

Heat Transfer Equipment

Heat Transfer Equipment Heat Transfer Equipment THE BROADEST SELECTION AVAILABLE FOR GENERAL HEATING AND COOLING. PR ODUC Shell & Tube Heat Exchangers PRE-ENGINEERED FOR GENERAL APPLICATIONS SX2000 Pre-engineered fixed tubesheet

More information

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260 SERIES 40/40D AND C250/260 Designed for a variety of high pressure and high capacity applications found in utility, industrial and marine service FEATURES Designed to fail open. Designed for superheat

More information

Removal of Non-condensable Gases and Air Is Critical In A Steam System

Removal of Non-condensable Gases and Air Is Critical In A Steam System Removal of Non-condensable Gases and Air Is Critical In A Steam System Air and non-condensable gases are one of the major problems in a steam system. Both can cause production problems for a steam system

More information

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS THERMODYNAMIC S has a wide variety of Thermodynamic Steam Traps to accommodate applications through 600 psi. Most models utilize s exclusive Celtron Cartridge. The Celtron facilitates inline maintenance

More information

9707 Key West Avenue, Suite 100 Rockville, MD Phone: Fax:

9707 Key West Avenue, Suite 100 Rockville, MD Phone: Fax: 9707 Key West Avenue, Suite 100 Rockville, MD 20850 Phone: 301-740-1421 Fax: 301-990-9771 E-Mail: awt@awt.org Part of the recertification process is to obtain Continuing Education Units (CEUs). One way

More information

Open System Condensate receiver tank of cylindrical. design type SDR A with highpressure

Open System Condensate receiver tank of cylindrical. design type SDR A with highpressure GESTRA Condensate Recovery and Return Systems GESTRA : ++49 (0) 421-35 03 566 Condensate flowrate Condensate temperature Condensate pressure Tank design: Cylindrical Rectangular Horizontal Vertical Condensate

More information

Steam and Gas Power Systems Prof Ravi Kumar Department of Mechanical and Industrial Engineering Indian Institute of Technology - Roorkee

Steam and Gas Power Systems Prof Ravi Kumar Department of Mechanical and Industrial Engineering Indian Institute of Technology - Roorkee Steam and Gas Power Systems Prof Ravi Kumar Department of Mechanical and Industrial Engineering Indian Institute of Technology - Roorkee Module No # 02 Lecture No # 09 Boilers Mountings and Accessories

More information

STEAM AND TRAP FUNDAMENTALS

STEAM AND TRAP FUNDAMENTALS STEAM AND TRAP FUNDAMENTALS Nick Westerberg Westerberg and Associates Newman Lake, WA Steam is an invisible gas that is generated by adding heat energy to water, usually from burning fuel in a boiler.

More information

Reactor-Boiler and Auxiliaries - Course 433 BOILER STEAM AND WATER SYSTEMS

Reactor-Boiler and Auxiliaries - Course 433 BOILER STEAM AND WATER SYSTEMS Lesson 433.60-1 Reactor-Boiler and Auxiliaries - Course 433 BOILER STEAM AND WATER SYSTEMS It was noted in an earlier lesson, that the reactor is a source of heat, and serves the purpose of a "furnace"

More information

EZ Plate Instantaneous

EZ Plate Instantaneous EZ Plate Instantaneous Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water PVI.com Packaged Instantaneous Domestic Hot Water EZ Plate Instantaneous is a factory-packaged, skid-mounted

More information

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need. A wide range of process thermostatic steam traps is available to match almost any application need. FEATURES Simple construction Easy to maintain as installed Excellent air handling capability Pressure

More information

Hoffman Specialty General Catalog

Hoffman Specialty General Catalog Hoffman Specialty General Catalog HS-900E ESP-PLUSTM For computer aided selection of Steam Trap and Regulators, please refer to the Steam Specialty Component Selectors in the Hoffman Specialty website

More information

Liquid Drainers LIQUID DRAINERS

Liquid Drainers LIQUID DRAINERS Liquid Drainers 206 Liquid Drainers Model/Series Type Body Material PMO Sizes Connection Page No. (PSIG) WLDE Float Ductile Iron 200 1 1 /2, 2, 2 1 /2 NPT WLDES Float Cast Steel 300 2 1 /2 NPT, SW, FLG

More information

UNIVERSAL STYLE STEAM TRAPS WU450 Series

UNIVERSAL STYLE STEAM TRAPS WU450 Series Watson McDaniel reserves the 2010 Watson McDaniel Company UNIVERSL STYLE STEM TRPS WU450 Series Universal Connectors for Universal Steam s STEM TRPS Model WU450, WU450S, WU450SB WU450S-LR, WU450SB-LR,

More information

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw SEMI-INSTANTANEOUS ENERGY: STEAM TO WATER U-TUBE SINGLE-WALL & DOUBLE-WALL HEAT EXCHANGERS FLOOR DRAIN Typical Construction Figure 34-1 FLOOR DRAIN 1. U-tube

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section includes criteria for the design of building heat generating systems including all isolation valves and steam piping and fittings, steam specialties, control

More information

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier OM001 Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier These operating and maintenance instructions are for standard semi-storage calorifiers (vessels fitted with

More information

05/14/2012 BOILER TUNE UPS & REPLACEMENTS PRESENTATION BOILER BASICS FOR LARGE INDUSTRIAL FACILITIES. Mark Bergum, P.E.

05/14/2012 BOILER TUNE UPS & REPLACEMENTS PRESENTATION BOILER BASICS FOR LARGE INDUSTRIAL FACILITIES. Mark Bergum, P.E. BOILER TUNE UPS & REPLACEMENTS FOR LARGE INDUSTRIAL FACILITIES Mark Bergum, P.E. PRESENTATION BOILER BASICS 1 BASE ASSUMPTION BOILER Steam Heat Output Exhaust Heat Losses 70% 20% Other Heat Losses 3% Blowdown

More information

ASME Packaged Indirect Fired Water Heater

ASME Packaged Indirect Fired Water Heater Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining provides superior protection and tank longevity Heavy duty construction withstands

More information

Math & Physics. Complete combustion requires an Air-FuelRatio of 14.7 to 1 for combustion.

Math & Physics. Complete combustion requires an Air-FuelRatio of 14.7 to 1 for combustion. Plant OPS Math & Physics Complete combustion requires an Air-FuelRatio of 14.7 to 1 for combustion. Math & Physics Increasing oxygen levels by 9 to 15% improves boiler efficiency. Math & Physics Draft

More information

BASCO TYPE ES EXTENDED SURFACE PLATE FIN HEAT EXCHANGERS. ...world leaders in heat transfer technology

BASCO TYPE ES EXTENDED SURFACE PLATE FIN HEAT EXCHANGERS. ...world leaders in heat transfer technology BASCO TYPE ES EXTENDED SURFACE PLATE FIN HEAT EXCHANGERS...world leaders in heat transfer technology Everything you want in a heat exchanger and less API Heat Transfer Basco Type ES Extended Surface Plate

More information

NHS Sustainable Development: 14 th February Reduce Energy Consumption Through Steam System Modernisation. National Key Account Manager

NHS Sustainable Development: 14 th February Reduce Energy Consumption Through Steam System Modernisation. National Key Account Manager NHS Sustainable Development: 14 th February 2012 Reduce Energy Consumption Through Steam System Modernisation Presentation by: Andy Bennett National Key Account Manager 1 Overview 1. Thermal Energy International

More information

VENTED CYLINDER RANGE

VENTED CYLINDER RANGE VENTED CYLINDER RANGE FULL RANGE OF VENTED CYLINDERS MANUFACTURED FROM EITHER COPPER OR STAINLESS STEEL ONE NAME. EVERY SOLUTION. WWW.GLEDHILL.NET CONTENTS BUILT ON EXPERIENCE THE GLEDHILL BRAND HAS BEEN

More information

SEH Series. Stainless Steel Instantaneous Packaged Steam Fired Water Heaters

SEH Series. Stainless Steel Instantaneous Packaged Steam Fired Water Heaters SEH Series Stainless Steel Instantaneous Packaged Steam Fired Water Heaters utomated On-line Sizing Program CEMLINE CORPORTION P.O. BOX 55 CHESWICK, PENNSYLVNI 15024 Phone: (724) 274-5430 FX: (724) 274-5448

More information

BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP. ...world leaders in heat transfer technology

BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP. ...world leaders in heat transfer technology BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP...world leaders in heat transfer technology The Basic Operation of Type T and TC Separators Basco Type T and TC Separators are designed to remove entrained

More information

Series 1140 and 1141 Temperature Regulators

Series 1140 and 1141 Temperature Regulators Hoffman Specialty Installation & Maintenance Instructions HS-504(E) Series 1140 and 1141 Temperature Regulators! CAUTION FOLLOW ALL INSTALLATION AND OPERATING INSTRUCTIONS. TURN OFF WATER OR STEAM BEFORE

More information

TYPE.005 DA-2C. Deaerating Boiler Feed Pumps. SHIPCO Deaerators can save you money!!! BULLETIN 149 Revised 8/09

TYPE.005 DA-2C. Deaerating Boiler Feed Pumps. SHIPCO Deaerators can save you money!!! BULLETIN 149 Revised 8/09 SHIPPENSBURG PUMP CO., INC. P.O. BOX 279, SHIPPENSBURG, PA 17257 PHONE 717-532-7321 FAX 717-532-7704 WWW.SHIPCOPUMPS.COM BULLETIN 149 Revised 8/09 TYPE.005 DA-2C Deaerating Boiler Feed Pumps SHIPCO Deaerators

More information

THERMOSTATIC STEAM TRAPS

THERMOSTATIC STEAM TRAPS THERMOSTATIC STEAM TRAPS Nicholson is the originator of the bellows actuated Thermostatic Steam. Nicholson s thermostatic product range spans applications from critical tracing to high capacity process.

More information

Commercial/Industrial Products. Partnerships beyond metals

Commercial/Industrial Products. Partnerships beyond metals Commercial/Industrial Products Partnerships beyond metals Company Overview We are committed to engineering, quality and flexible manufacturing. For over half a century, equipment manufacturers have recognized

More information

IMPROVING EFFICIENCY AND QUALITY USING A PERMANENT ORIFICE STEAM TRAPPING SYSTEM

IMPROVING EFFICIENCY AND QUALITY USING A PERMANENT ORIFICE STEAM TRAPPING SYSTEM IMPROVING EFFICIENCY AND QUALITY USING A PERMANENT ORIFICE STEAM TRAPPING SYSTEM Dave Walker Patti Lowe Matrix Northwest Portland, Oregon Introduction Thank you for being here to find out about permanent

More information

OPERATION & MAINTENANACE MANUAL

OPERATION & MAINTENANACE MANUAL OPERATION & MAINTENANACE MANUAL Client Name Vendor Name Capacity Document Name Document No. Bayer Hydropure Systems & Exergy LLC Point of Use Cooler 5 GPM Operation & Maintenance Manual HPS-PR247-O&M-001

More information

Hydronic Product & Application Catalog

Hydronic Product & Application Catalog Hydronic Product & Application Catalog Brazed Plate Heat Exchangers MJanuary 2005 for: Radiant Floor Heating Domestic Water Heating Snow Melt Swimming Pools Steam Close Approach High Pressure Systems Multi-Purpose

More information

UNIT 6 STEAM CONDENSERS

UNIT 6 STEAM CONDENSERS UNIT 6 STEAM CONDENSERS Steam Condensers Structure 6.1 Introduction Objectives 6.2 Condenser Types 6.3 Steam Surface Condenser Operation 6.3.1 Steam Surface Condenser Configurations 6.3.2 Water-cooled

More information

Boiler Basics. Design and operation

Boiler Basics. Design and operation Boiler Basics Design and operation A boiler is an enclosed vessel that provides a means for combustion heat to be transferred into water until it becomes heated water or steam. The hot water or steam under

More information