1 EN Operating instructions TopGas (35, 45, 60) To be fi lled in by the heating expert: Order No.: Boiler type: Set to: Natural gas H Natural gas L Liquid gas Heating pump type: Heating regulation type: Mixing organ type: Ancillary water heater type: Water heater sensor Thermostat Outdoor temperature sensor Room temperature sensor Combustion air supply Room Outdoor Design parameters of the heating Lowest outdoor temperature C Heat demand: kw Max. fl ow temperature: C Hoval Switzerland Hoval Herzog AG CH-8706 Feldmeilen General Wille Strasse 201 Telephone 01 / Fax 01 / Hoval Austria Hoval Gesellschaft mbh A-4614 Marchtrenk Hovalstrasse 11 Telephone / Fax / Important telephone numbers Heating engineer Sanitary installer Electrical installer Fuel supplier Chimney-sweep Hoval Germany Hoval Hagenberger GmbH D Aschheim Dornach Karl Hammerschmidt Strasse 45 Telephone 089 / Fax 089 / / 01-04/05 Subject to change

2 General Instructions Dear Hoval customer, You have acquired in the Hoval TopGas (35, 45, 60) a product, which has been manufactured to the latest state of the art and the highest quality. For regular installation and operation of your Hoval TopGas (35,45,60), you must comply with all applicable laws, regulations and standards, in particular the regulations of the responsible power supply companies. For any further inquiries please contact your specialist installer or your nearest Hoval customer services unit. Assembly and installation of the boiler may only be carried out by trained personnel of a licensed installation company. Before start-up an installation check must be carried out and the system must be cleared by the specialist. Please only operate your Hoval TopGas (35,45,60) on the basis of these operating instructions, in order to ensure safe and troublefree operation. The Hoval TopGas (35,45,60) may only be used for its intended purposes and fuels, for which it is suitable through its mode of construction and has been approved by Hoval. Do not carry out any changes to the system, otherwise all claims under the guarantee will be waived. Conversion kits are to be supplied and installed by a licensed installer or the Hoval after-sales service. With proper handling your Hoval system will guarantee you a comfortable living climate for many years. Safety instructions In the event of danger: Switch off fuel (gas) and electricity supply! In the event of exhaust and gas smell: / 01 Do not smoke Avoid open flame and sparks (e.g. switching lights and electrical appliances on and off) Disconnect the system and close the gas cock Open windows and doors Inform the heating specialist/installing contractor Follow the safety regulations of the gas supply company (see gas meters) and the heating specialist! Keep the air supply in the heating system room open (windows): Ventilation apertures should not be closed, if no direct combustion air flow takes place. Closed flow apertures can lead to incomplete combustion. This can lead to poisoning. Instructions to the protection of persons Instructions to the protection of the heating systems Intended purpose: The TopGas (of 35,45,60) boiler may only be operated with the fuels indicated in the technical information/installation guidelines. The heat produced must be removed by means of heating water. All openings of the boiler must be closed during operation! Important information 2

3 / 01 General Instructions Precautionary instructions: Corrosion protection Do not use sprays, solvents, chloric cleaning agents, dyes, adhesives etc. in the environment of the equipment. Sometimes these materials can lead to corrosion in the boiler and in the exhaust system. Water level control Check the water level of the system at regular intervals (page 9). Controls before the initial start-up A new system may only be taken into operation if it has been cleared for operation by the heating engineer. Filling the heating system The heating system is fi lled with tap water according to the instructions of the installer. The system must be drained of air. Check the pressure at the manometer or hydrometer. Filling the Heating System The water condition of the heating system water must be as detailed in our Installation Instructions manual. The TopGas (35, 45, 60) boiler has an aluminium silicon alloy heat exchanger. The use of chemical water addititives is not allowed. If the fi ll-up and make-up water volume exceed the volume, according to installation instructions, sections and 4.2.5, suitable water treatment or system separation is required. In the case of system separation the use of chemical water additives in the boiler circuit is also not allowed. The TopGas (35, 45, 60) boiler is only suitable for use with a sealed system. General information The Hoval gas boiler TopGas (35, 45, 60) is equipped with automatic adjustment and safety systems. Under normal conditions they are in operation from the beginning of the heating season to its end. During this time the necessary boiler temperature is set by means of the automatic heating regulation. If water heating is also provided through the heating boiler, then the boiler remains switched on for the whole year. Fuel Filling the ancillary water heater The water heater must be fi lled on the side of the consumption water according to the instructions of the installer. The boiler may be taken into operation even if the water heater is not fi lled. Safety valves The heating system and warm water system must be protected with one safety valve each from inadmissible excess pressure. Loading pump (boiler with ancillary water heaters) The number of revolutions and capacity control must correspond to the requirements of the ancillary tank. To be set by the heating expert. Heating pumps The number of revolutions and capacity control must correspond to the requirements of the system. They must be set by the heating expert. Electricity connection The electricity connection must be made by a specialist. The boiler may only be operated with the kind of gas indicated on the class identification plate. To be set by the installer. 3

4 Important instructions Important instructions Please close the main blocking clock ahead of the gas meter as soon as you smell gas and call the faults department of your gas supply company / 01 Installation and assembly instruction The installing company has given you installation and assembly instructions. Keep this important technical information securely, so that if necessary the customer service mechanic can at a later date discover the technical details on the spot. To ensure that no poisonous exhaust gases develop, the combustion air must fl ow unhindered into the gas boiler. Accordingly the ventilation opening provided (in the room temperature-sensitive mode of operation) (e.g. basement windows) may never be closed. Also the boiler itself may not be turned off. Always keep the room, in which your boiler is installed, clean and turn off the burner before cleaning, since dusty combustion air can lead to faults. Faults For your safety of the burner switches itself off automatically in the event of faults in the burner system, excessively low gas pressure, a gas leak or the exceeding of the maximum boiler temperature. Try fi rst to ignite the burner several times, after approximately 5 minutes of waiting period, by operating the clearing button (Reset) on the control panel of the boiler. If that does not succeed, please close the gas cock and inform your customer service or heating engineer. Imperative requirement! Perfect operation is only ensured if the operating instructions are followed and boilers as well as burners are maintained regularly by a specialist. Faults and damaged caused by installation in unsuitable areas, e.g. hobby rooms, workshops etc., as well as by dirty operational agents (gas, water, combustion air), unsuitable chemical additives to the heater water, inappropriate treatment, incorrect installation and damage by force do not fall under our warranty; this also applies to corrosion by halogen compounds e.g. from spray cans, paints, adhesives and solution and cleaning agents. 4

5 / 01 Start-Up/Taking out of Operation / Boiler Cleaning Preparation for start-up With a newly installed system the fi rst start-up may only be carried out by a specialist. Installation checks must be carried out in full. Maintenance and control Instructions on maintenance and control can be found on page 9. Set main switch to 0. Open the block valve in the heater fl ow and return pipe. By opening the heating system room window ensure air supply (fresh air) in the heating system room (only applies to room air-sensitive operation). Open the shut-off valve in the gas pipe to the boiler. Switch on the main switches outdoor the heating system room (if available). Often the heating system also has another danger switch, which only takes the gas burner out of operation. With the TopGas (35, 45, 60) the trap (siphon) in the condensate exhaust pipe should be fi lled with water before start-up. Start-up Operating instructions for boiler control (pages 6 and 7) with a figurative representation of the switch bay and detailed instructions are attached to these guidelines. These operating instructions should be followed for boiler control. Set main switch to I When lighting up the fault lamps please consult the section faults on page 4. Taking out of operation Set main switch to 0 Close gas shut off cock During a longer interruption, e.g. during your vacation, you can turn the heating system off. If there is a danger of frost, consult your heating engineer about suitable preventive measures, antifreeze may not under any circumstances enter the boiler circuit. 5

6 Control / 01 Control of the boiler User-dependent settings (e.g. room temperature) are made to the TopTronic R-S 30 and/or to the TopTronic 1B/133B. This is preferably in the livingroom (R-S 30) and/or to the boiler (TopTronic 1 B/133B). If you do not have a TopTronic, these settings are made on the basic control. The control panel of the basic control is behind the lower front lining. The main switch (O/I) for the taking of the boiler out of operation is also behind the lower front lining in the control panel. Normally no settings are required by the user to the basic control. All settings will have been made by the installer or by the manufacturer. Main switch TopTronic-RS 30 in the livingroom Control panel Manometer TopTronic -RS For the operation of the TopTronic R-S 30 please consult the special operating instructions 1 LCD display 2 Key for upward adjustments 3 Key for downward adjustments 4 Key for heating program 5 Key for lowering program 6 Information key 6

7 / 01 The Controls of the Boiler Controls * * also available without electronic heating regulator Legend Function 1. Operating selector switch; ON/OFF O = Off Boilers and burners are out of operation Note: No freeze protection I SYSTEM = On The boiler is in operation 2. Basic control - Controls the boiler s internal functions Settings and changes may only be made by the heating engineer. In the event of faults the display fl ashes. For clearing fold the cover down and press the clearing button 3. Electronic heater radiator 4. Control setting - Ensures the correct room temperature for each outdoor temperature - Regulates the heating of the water heater etc.. The heating regulator has its own special guidelines - Central position 20 C The room temperature can be changed here by ± 8 C 7

8 The controls of the boiler / 01 Legend 5. Control setting reduced Function - Here the desired room temperature for the night can be set Central position 14 C ± 6 C 6. Program switch Here the heating program can be selected: Heating and hot water load OFF. Frost protection is ensured The adjusted room temperature for the night is also effective during the day Hot water according to clock program The automatic default operation corresponds to the switching times entered for the fi rst programme (Daytime intermediate reduction) The automatic default operation corresponds to the switching times entered for the second programme (normalposition) The automatic default operation corresponds to the switching times entered for the third programme (longer period of operation) The room temperature is not lowered in the night Hot water according to clock program 2 Summer operation: Heating OFF Frost protection and hot water load works according to clock program 2 Hand operation for the specialist. Burner and heating circulation pump are in operation. Mixing valve disconnected, hot water loading remains in operation 7. Inquiry and programming keys 8. Display area Here settings such as time can be entered and values can be queried. The setting takes place according to special operating instructions Here the current time, the current boiler temperature and possibly the water heater temperature are alternately displayed 9. Operating instructions Short operating instructions only for heating regulator (3) 10. Room station When desired Makes possible the operation of the heating regulator (3) in the livingroom. If a room station is attached, the settings are replaced by the settings on the room station. 8

9 / 01 Maintenance and Control Maintenance and control Normally these are carried out by the specialist on the occasion of the annual maintenance. Nevertheless, you should carry out the following controls and if necessary implement the works described. Check water level With excessively low water pressure in the system (readable at the manometer), you should inform your installer and/or refill the water. Refilling the heating The boiler must be switched off! (disconnected from the net) The stop valves in the heater fl ow and return pipes must be open. The connection between the boiler filling/emptying cock and the tap is established through a fi lled hose (no air should enter the heating system); this should be unscrewed again after fi lling, in order to interrupt the connection securely. The water quality must correspond to the criteria described on page 4 of the installation guidelines. Slowly fi ll in the water and check the water level at the manometer (ask for the fi lling pressure for your system from the installer). The bleed valves on the heating elements must be kept open, until only water fl ows out. Complete filling and emptying should be implemented by the heating expert. Note: Never fill cold water into the hot system. Boiler and burner Have the burner and boiler as well as any neutralisation mechanism checked and maintained periodically - DIN 4756 recommends at least one maintenance every year. This maintenance is particularly important with a high effi ciency boiler such as this Hoval TopGas, in order to achieve the optimal annual consumption. You can conclude a servicing contract with your heating engineer or the responsible customer service organisation. Maintenance of the neutralisation The local regulations of the responsible local waste water authority must be complied with. If the condensate of your boiler is neutralised before introducing in the waste water, the neutralisation system must be periodically cleaned and fi lled with new granulates. Follow the guidelines for your neutralisation system. Check before the start of the heating season whether the siphon of the condensate drainage pipe is filled. Hot-water supply Regular controls increase the life span and effi ciency of any throughput and/or ancillary water heater. During the cleaning submerged parts are removed. The maintenance service will carry out this work. In areas with calcium rich water the water heater and/or the throughput heater - in the interest of an economic hot-water supply - should be periodically decalcifi ed (1 x annually). The water heater may not be worked on with metal tools when decalcifying. With highly calcium rich water the installation of a water softening system is a good idea. 9

10 Check list in the event of faults / 01 Fault Check/cause Remedy See page Gas boiler - Is there a current - Check fuses. Switch on the main and does not if necessary emergency switches start - Is the gas shut off cock open - Open it - Is a number fl ashing on the basic control - Note the number - Press the clearing key (Reset key) - Inform customer service indicating the fi gure fl ashing - Is there gas present - Contact the gas company Radiators do - Are the blocking valves in the heating - Open them not heat up fl ow and return pipes open - Is OFF indicated on the control panel - Switch on 6 - Press the - key until the OFF sign disappears in the display - Is the time switch of the TopTronic set - Check in accordance with separate operating correctly guidelines of the heating regulation - Check the water level and/or - pressure - Refi ll the water and drain air from the 4 in the heating system heating system - Are the radiator valves open - Open them - The heating circulation pump is not - Open the plug working Turn the shaft end with a screwdriver fi rmly until the resistance reduces - Mixing organ does not open automatically - Open by hand; contact customer services No hot water - The loading pump is not working - Open the plug Turn the shaft end with a screwdriver fi rmly until the resistance reduces - Air is in the loading pipe - If necessary, drain the air by hand - Operate the automatic air drainer annually Please note the following! In the event of operating faults please carry out the checks in accordance with the above checklist. If you cannot remove the fault, please call the heating engineer or Hoval customer service. 10

11 / 01 This saves you energy! The room temperatures and periods of operation of the heat ing system have a crucial influence on the fuel consump tion. 1 C lower room temperature produces up to 6% fuel saving. So bear in mind the following tips: Avoid room temperatures above 20 C and adjust your heating system accordingly. It is worthwhile to turn the radiators off of unused rooms as long as there is no danger of frost and no dampness damage to the building construction and to the furniture is to be expected. In main living rooms, body heat, television sets, fire-places and so lar radiation often produce heat gains. These cannot be balanced with a weather-dependent regulation. It may be worthwhile to install a remote control (R-S 30) and/or a room sensor or attach thermostatic radiator valves in these rooms. If there is a draft in the house, this is not only unpleasant, but at the same time means a loss of heating power. So you can save fuel, if you... Keep doors and windows closed in the winter. Close chimney fl aps, if the fi re is out. Only operate kitchen and bathroom fans if steam and smells must be extracted. Only ventilate briefl y, but repeatedly. Seal doors and windows, so that constant leakage losses are avoided. Through installation you can retain precious heat. Exploit these possibilities and... Close windows and doors at night. Make sure that heating and hot water pipes are insulated in unheated areas The lowest possible heating element temperature prevents unnecessary heat losses. So the heating element must always be able to deliver its heat to the room without impediment. So avoid: Covered heating elements Window sills, which do not let air through, because they are cluttered with objects. Even for water heating there are possible economies. The hot-water temperature should be set as low as possible. Test at which temperature there is still suffi cient hot water. If you have included a hot water circulating pump in your installation, then it is worthwhile to turn it off at night with a time switch. 11

12 Maintenance Contract / 01 Maintenance contract The Hoval customer service maintenance contract In order to ensure troublefree and economical operation of your new heating system, we recommend using the Hoval customer service maintenance contract. With this contract the Hoval customer service department takes over for you the date co-ordination for the maintenance works required each year. In the period April to October - according to previous contract of the date - your boiler is thoroughly reviewed, checked and measured and adjusted to optimal operation. Any necessary repairs are carried out immediately with your contract. There are several advantages of a maintenance contract The guarantee period is increased by concluding it. Your heating system is always optimally adjusted - this saves heating costs and preserves the environment. High working reliability, because in the course of maintenance possible causes of malfunction can be promptly recognised and repaired. The optimal setting and regular maintenance increase the life span of your heating still further The attractive lump-sum price. Except for any necessary spare parts nothing extra has to be paid for maintenance. Make a record here of controls, revisions, fuel purchases etc Date Text: 12

13 / 01 For Your Notes 13

14 For Your Notes / 01 14

15 / 01 For Your Notes 15

16 / 01 Switzerland CH-8706 Feldmeilen General Wille Strasse 201 Telephone Fax Pikett outside offi ce hours: Tel Basel, Schneckelerstr. 9, 4414 Füllinsdorf Tel , Fax kc.basel@hoval.ch Zurich, P.O. Box, 8706 Feldmeilen Tel , Fax kc.zuerich@hoval.ch East Switzerland, P.O. Box, 8706 Feldmeilen Tel , Fax kc.ostschweiz@hoval.ch Suisse romande, Ch. de Closalet 12,1023 Crissier Tél , Fax crissier@hoval.ch Ventilation and System Engineering, P.O. Box 8706 Feldmeilen Tel , Fax kc.umwelt-energien@hoval.ch Bern, Aemmenmattstr. 43, 3123 Belp Tel , Fax kc.bern@hoval.ch Central Switzerland, P.O. Box, 8706 Feldmeilen Tel , Fax kc.zent.schweiz@hoval.ch Vaduz, Austrasse 70, FL-9490 Vaduz Tel , Fax kc.vaduz@hoval.ch Ticino, Via Cantonale 34A, 6928 Manno Tel , Fax manno@hoval.ch Austria A-4614 Marchtrenk, Hovalstrasse 11 Telephone / Fax / Tel. Sales / , Fax / Customer service / Fax / kc.marchtrenk@hoval.at A-6845 Hohenems, Franz-Michael-Felder-Strasse 6 Telephone 05576/ , Fax 05576/ kc.hohenems@hoval.at A-6020 Innsbruck, Etrichgasse 34 Telephone 0512/ , Fax 0512/ kc.innsbruck@hoval.at A-8041 Graz, Messendorfer Strasse 6 Telephone 0316/ , Fax 0316/ kc.graz@hoval.at A-1220 Vienna, Percostrasse 26 Telephone 01/ , Fax 01/ kc.wien@hoval.at Germany Hoval Hagenberger GmbH Bavaria Karl Hammerschmidt Strasse 45 D Aschheim-Dornach Telephone 089 / Fax 089 / info.de@hoval.com Hoval Sales and Service Center North Company Hormann Danziger Strasse 10 D Harpstedt Telephone Fax Responsibility for energy and environment

Operating instructions

Operating instructions ENG Operating instructions Heating controller TopTronic T Hoval Switzerland Hoval Herzog AG CH-8706 Feldmeilen General-Wille-Strasse 201 Telephone 044 / 925 61 11 Fax 044 / 923 11 39 Hoval Austria Hoval

More information

Operating constructions

Operating constructions EN Operating constructions Heating controller Top Tronic T Hoval Schweiz Hoval Herzog AG CH-8706 Feldmeilen General-Wille-Strasse 201 Telefon 044 / 925 61 11 Telefax 044 / 923 11 39 Hoval Österreich Hoval

More information

Operating instructions

Operating instructions EN Operating instructions TopGas classic (12,18,24) Hoval United Kingdom Hoval LTD Northgate Newark Nottinghamshire NG24 1JN Phone: +44 1636 67 27 11 Fax: +44 1636 67 35 32 Hoval Export Hovalwerk AG Austrasse

More information

ENG Operating Instructions

ENG Operating Instructions ENG Operating Instructions Brine/Water and Water/Water Heat Pumps Thermalia (5-45) and (8H-45H) 4 204 743 / 02-06/07 Subject to modifications Important Addresses... 3 Safety Instructions... 4 Heating Control...5-7

More information

Operating instructions

Operating instructions ENG Operating instructions Wood burning boiler AgroLyt (20-50) Hoval Export Austrasse 70 9490 Vaduz Principality of Liechtenstein Phone: +423 399 2400 Fax: +423 399 2618 Export@hoval.com Hoval LTD Northgate

More information

Operating instructions

Operating instructions Operating instructions Gas-fired condensing boiler Logano plus GB312 For the user Please read carefully before use 7 747 009 296-01/2007 EN Contents 1 For your safety..............................................

More information

/2010 US/CA

/2010 US/CA 6 720 646 148-11/2010 US/CA (en) For the user User s Instructions Condensing gas boiler Logamax plus GB162-L.B. 80 kw/100 kw Please read thoroughly before operating This manual is available in the English

More information

Operating Instructions

Operating Instructions EN Operating Instructions Wood burning boiler AgroLyt (20-50) Hoval United Kingdom Hoval Ltd. Northgate Newark Nottinghamshire NG24 1JN Phone +44 1636 67 27 11 Fax +44 1636 67 35 32 Hoval Export Hoval

More information

atmocraft VK 654/9-1654/9 DE/AT/GB/CZ/SK/HU/PL/HR/SI/SCG

atmocraft VK 654/9-1654/9 DE/AT/GB/CZ/SK/HU/PL/HR/SI/SCG atmocraft VK 654/9-654/9 DE/AT/GB/CZ/SK/HU/PL/HR/SI/SCG For the owner Operating manual atmocraft Gas heating boiler VK 654/9-654/9 GB Contents Appliance characteristics Contents Appliance characteristics.....................

More information

VIESMANN. Operating instructions VITODENS 100-W. for the system user

VIESMANN. Operating instructions VITODENS 100-W. for the system user Operating instructions for the system user VIESMANN Heating system with control unit for constant temperature or weather-compensated mode VITODENS 100-W 1/2012 Please keep safe. Safety instructions For

More information

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A... 70 80 99-00-O Residential Gas Condensing Boiler ZBR//8/35/4-3A... ZWB8/35/4-3A... 70 80 993 (03/03) CA/US Operating Instructions Contents Contents Key to symbols and safety instructions............................

More information

VIESMANN. Operating instructions VITODENS 111-W. for the system user

VIESMANN. Operating instructions VITODENS 111-W. for the system user Operating instructions for the system user VIESMANN Heating system with control unit for constant temperature or weather-compensated mode VITODENS 111-W 4/2012 Please keep safe. Safety instructions For

More information

Electronically controlled instantaneous water heater. DEX: C models. Instructions for the user

Electronically controlled instantaneous water heater. DEX: C models. Instructions for the user Electronically controlled instantaneous water heater DEX: 27930-50 C models Instructions for the user For 50 ºC models, the appliance delivers water not exceeding 50 ºC in accordance with AS3498. MADE

More information

Gas condensing boiler (wall mounted) TopGas

Gas condensing boiler (wall mounted) TopGas Gas condensing boiler (wall mounted) TopGas Modern gas condensing technology generates up to 15 % more heat from the consumed energy source. TopGas. Advanced technology attractive and compact. TopGas.

More information

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r. Ultracom cxi High Efficiency Condensing System Boilers Instructions for Use To b e l e f t w i t h t h e u s e r WARNING GAS LEAK OR FAULT Turn off the gas emergency control valve immediately. Eliminate

More information

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions. User Manual for model FLOWMAX-90 Condensing water heater 85,000 BTU WARNING If the information in these instructions is not followed exactly, a fire or explosion may result, causing property damage, personal

More information

Users manual. Buderus /29/43/60 and Buderus T25/29T25 H/V. Wall-mounted condensing gas boiler. For the user

Users manual. Buderus /29/43/60 and Buderus T25/29T25 H/V. Wall-mounted condensing gas boiler. For the user Users manual Wall-mounted condensing gas boiler Buderus 800-24/29/43/60 and Buderus 800-24T25/29T25 H/V For the user Please read thoroughly before operating the unit 722 3700 (03/200) GB Preface Introduction

More information

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit Operating instructions for the system user VIESMANN With constant temperature or weather-compensated control unit VITODENS 050-W 9/2014 Please keep safe. Safety instructions For your safety Please follow

More information

Operating instructions

Operating instructions Operating instructions Gas condensing boiler WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

More information

Electronically controlled instantaneous water heater CEX 9. CEX9: C models. Instructions for the user

Electronically controlled instantaneous water heater CEX 9. CEX9: C models. Instructions for the user Electronically controlled instantaneous water heater CEX 9 CEX9: 27900-50 C models Instructions for the user For 50 ºC models, the appliance delivers water not exceeding 50 ºC in accordance with AS3498.

More information

WHE 2.24 / WHE 2.24 FF

WHE 2.24 / WHE 2.24 FF EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3

More information

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB 6 720 648 662-00.1T UNI 7000 F Operating instructions For the user AU/G 2 Contents Contents Contents 2 1 Safety information and explanation of symbols 3 1.1 For your safety 3 1.2 Explanation of symbols

More information

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600 I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d Model code: BORA600 Contact Caple on 0844 8003830 or for spare parts www.4caple.co.uk 1 Y O U R A P P L I A N C E Thank you for buying your

More information

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A... Residential Gas Condensing Boiler Greenstar combi 00 p / 5 p ZWB8-3A... ZWB4-3A... Operating Instructions 708733 (07/04) US/CA Contents Contents Explanation of symbols and safety instructions.......................

More information

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI For the owner Operating manual ecotec plus 937 Gas condensing storage combination boiler GB VUI Contents Appliance characteristics Recommended accessories Contents Appliance characteristics... Recommended

More information

Riva FP USER MANUAL AND INSTRUCTIONS WALL HUNG GAS BOILER FOR CENTRAL HEATING SUPPLY. Please Read Instructions Carefully Save for Future Reference

Riva FP USER MANUAL AND INSTRUCTIONS WALL HUNG GAS BOILER FOR CENTRAL HEATING SUPPLY. Please Read Instructions Carefully Save for Future Reference USER MANUAL AND INSTRUCTIONS Riva FP WALL HUNG GAS BOILER FOR CENTRAL HEATING SUPPLY Please Read Instructions Carefully Save for Future Reference WARNING: If the information in this manual is not followed

More information

USER GUIDE VOGUE MAX SYSTEM

USER GUIDE VOGUE MAX SYSTEM USER GUIDE VOGUE MAX SYSTEM 15 18 26 32 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not

More information

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit 7215 3200-02/2006 GB (EN) For the user Users Manual Gas wall hung Boiler condensing Buderus 500-24/S Please read thoroughly before operating the unit Introduction Please read these instructions and follow

More information

Gas condensing boiler UltraGas

Gas condensing boiler UltraGas Gas condensing boiler UltraGas Patented alufer for a high efficiency and low emission. 1 UltraGas (15-90) and (125-2000D). Advantages at a glance. The UltraGas condensing boiler with patented alufer heat

More information

Operating instructions Oil condensing boiler

Operating instructions Oil condensing boiler Operating instructions Oil condensing boiler COB COB-CS Boiler for heating Boiler with stratification cylinder Wolf GmbH Postfach 1380 D-84048 Mainburg Tel. +49-8751/74-0 Fax +49-8751/741600 Internet:

More information

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode Operating instructions for the system user VIESMANN Heating system with Vitotronic 100 control unit for constant temperature mode VITODENS VITOPEND 4/2007 Please keep safe. Safety instructions For your

More information

User Manual for model RK 18 RK 25 RK 34 CE 0694 RK 18_25_34 - RAD - ING - MAN.UT A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD

User Manual for model RK 18 RK 25 RK 34 CE 0694 RK 18_25_34 - RAD - ING - MAN.UT A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD User Manual for model RK 18 RK 25 RK 34 Premix condensing boiler User instruction CE 0694 RK 18_25_34 - RAD - ING - MAN.UT - 1104A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD Technical specification by

More information

TopGas Wall Hung Condensing Gas Boiler

TopGas Wall Hung Condensing Gas Boiler TopGas Wall Hung Condensing Gas Boiler Output range 30 to 80 kw Why choose TopGas? TopGas wall-hung boilers offer compact and advanced gas heating technology built to the high quality standards you would

More information

WARMCAIR. Condensing Air & Water Heater. High Efficiency Downflow Condensing Air & Water Heater USERS INSTRUCTIONS

WARMCAIR. Condensing Air & Water Heater. High Efficiency Downflow Condensing Air & Water Heater USERS INSTRUCTIONS WARMCAIR Condensing Air & Water Heater Publication No. ZZ 1449-2 September 2016 High Efficiency Downflow Condensing Air & Water Heater USERS INSTRUCTIONS Warmcair C10DW - G.C. No. 43-417-59 Warmcair C16DW

More information

Heating with log wood

Heating with log wood English Heating with log wood De Luxe 18-40 Lambda 18-40 1 Competence is our success... HERZ FACTS: 60 subsidiaries Group headquarter in Austria Research & development in Austria Austrian owner 2.600 employees

More information

ir-range 8G /03.15 Changes reserved.

ir-range 8G /03.15 Changes reserved. U s e r m a n u a l ic-range is-range ir-range 8G.52.80.00/03.15 Changes reserved. Contents 1. Introduction...3 2. Safety...5 3. Boiler description...6 4. Display and functions...7 4.1 DHW and Heating

More information

The guarantee on this appliance is valid for 12 months from the first day of installation.

The guarantee on this appliance is valid for 12 months from the first day of installation. Users Manual Dear Customer, Thank you for choosing an ARISTON boiler. We guarantee that your boiler is a reliable and technically sound product. This Users Manual provides detailed instructions and recommendations

More information

TERMO-Blok TERMO-Extra TERMO-Blok PTV

TERMO-Blok TERMO-Extra TERMO-Blok PTV ELECTRIC BOILERS FOR CENTRAL HEATING TERMO-Blok TERMO-Extra TERMO-Blok PTV Contents 1. Introduction... 1 1.1. Applicable documents... 1 1.2. Retention of documents... 1 1.3. Introduction... 1 1.4. Heating

More information

Operating instructions

Operating instructions 6304 0307 04/2005 US For the installer Operating instructions Sealed combustion boiler Logano GA24 SC and atmospheric boiler Logano G24X II/SP If these instructions are not followed exactly, a fire or

More information

Operating instructions

Operating instructions Operating instructions Capriz 2 24c 28c GB, IE Contents Contents 1 Safety... 3 1.1 Action-related warnings... 3 1.2 Intended use... 3 1.3 General safety information... 4 2 Notes on the documentation...

More information

USERS GUIDE 24, 30. For installation guide see reverse of book

USERS GUIDE 24, 30. For installation guide see reverse of book USERS GUIDE 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification

More information

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler Gas boiler UPON COMPLETION OF THE INSTALLATION THE INSTALLER MUST INSTRUCT THE OWNER AND OPERATOR ON THE FUNCTIONALITY AND THE PROPER OPERATION OF THE BOILER AND THE HEATING SYSTEM. INSTALLER MUST REVIEW

More information

User Manual for model

User Manual for model User Manual for model RKA 24/8 RKA 24 RKA 28 RKA 34 Wall mounted storage combi boiler premix condensing boiler User instruction CE 0694 RKA 24.8_24_28_34 - RAD - ING - MAN.UT - 1104A - DIGITECH 2 - REGNO

More information

Operating instructions

Operating instructions The energy you need Operating instructions Betacom 3 24c -A (H-GB) 30c -A (H-GB) GB, IE Contents Contents 1 Safety... 3 1.1 Action-related warnings... 3 1.2 Intended use... 3 1.3 General safety information...

More information

E-COMBI EVO E-SYSTEM EVO

E-COMBI EVO E-SYSTEM EVO E-COMBI EVO E-SYSTEM EVO User s manual CONDENSING WALL-HUNG GAS BOILER G.C.N.:47-116-68 (24 kw) G.C.N.:47-116-69 (30 kw) G.C.N.:47-116-70 (38 kw) G.C.N.:41-116-39 (24 kw) G.C.N.:41-116-40 (30 kw) Country

More information

INSTRUCTION FOR THE USER THC V E OIL BLU

INSTRUCTION FOR THE USER THC V E OIL BLU INSTRUCTION FOR THE THC V E OIL BLU CONTENTS General safety information 4 Precautions 4 Control panel 5 Mode selection 8 User levels 10 Start-up 12 Temporary shutdown 15 Preparing for extended periods

More information

HERZ ECO-Line Heating with logs or wood pellets

HERZ ECO-Line Heating with logs or wood pellets English HERZ ECO-Line Heating with logs or wood pellets Lambda 18-40 10-60 1 Competence is our success... HERZ FACTS: 50 companies Group headquarter in Austria Research & development in Austria Austrian

More information

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r. Ultracom hxi High Efficiency Condensing System Boilers Instructions for Use To b e l e f t w i t h t h e u s e r WARNING GAS LEAK OR FAULT Turn off the gas emergency control valve immediately. Eliminate

More information

Technical information. Remeha P 500. Pressurized boiler. Heat output: kw

Technical information. Remeha P 500. Pressurized boiler. Heat output: kw Technical information Remeha P 500 R e m e h a P 5 0 0 Pressurized boiler Heat output: 635-1900 kw Remeha P 500 TABLE OF CONTENT Preface 3 1 Description of the unit 3 1.1 General 3 1.2 Burners 3 2 Construction

More information

USERS GUIDE. LOGIC+ Combi 24, 30, 35

USERS GUIDE. LOGIC+ Combi 24, 30, 35 USERS GUIDE LOGIC+ Combi 24, 30, 35 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use

More information

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en 8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................

More information

USER GUIDE LOGIC HEAT H

USER GUIDE LOGIC HEAT H USER GUIDE LOGIC HEAT H 12 15 18 24 30 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not

More information

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER System s30 User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER When replacing any part on this appliance, use only spare parts that you can be assured conform to the

More information

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit Service instructions for contractors VIESMANN Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit VITOLADENS 300-T 1/2007 Please keep safe. Safety instructions Safety instructions

More information

DTG Eco / V130

DTG Eco / V130 ECODENS Gas fired condensing boiler EN User Guide 300010111-001-B Contents 1 Introduction.............................................................................3 1.1 Symbols and abbreviations................................................................................3

More information

/2005 GB(EN) For the user. Wall-mounted condensing gas combi boiler Buderus /C, /C

/2005 GB(EN) For the user. Wall-mounted condensing gas combi boiler Buderus /C, /C 7215 3500-02/2005 GB(EN) For the user Users manual Wall-mounted condensing gas combi boiler Buderus 500-24/C, 500-28/C Please read thoroughly before operating the unit Introduction Please read these instructions

More information

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation Operating instructions for system users VIESMANN Heating system with control unit for constant temperature operation VITODENS 100 2/2005 Please keep safe Safety instructions For your safety Please follow

More information

Operating instructions. For the operator. Operating instructions. ecotec. Gas fired wall hung high efficiency boiler.

Operating instructions. For the operator. Operating instructions. ecotec. Gas fired wall hung high efficiency boiler. Operating instructions For the operator Operating instructions ecotec Gas fired wall hung high efficiency boiler Channel Islands Inhaltsverzeichnis Inhaltsverzeichnis 1 Notes on the documentation...3 1.1

More information

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40 USER GUIDE VOGUE COMBI GEN2 C26 C32 C40 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not

More information

Operating instructions

Operating instructions Operating instructions For the operator Operating instructions HOME SYSTEM GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Tel. +49 21 91 18 0 Fax +49 21 91 18 28 10 info@vaillant.de

More information

Operating Instructions

Operating Instructions Operating Instructions Low Emissions and High Efficiency Condensing Oil Boiler DANGER! If these instructions are not followed exactly, a fire or explosion may be caused with serious property damage or

More information

User s Information Manual

User s Information Manual User s Information Manual Series 2 Models 1000-2000 MBH Commercial Condensing Gas-fired water boilers If the information in this manual is not followed exactly, a fire or explosion may result, causing

More information

Installation and maintenance instructions

Installation and maintenance instructions 6304 4995 0/004 GB For installer Installation and maintenance instructions Flue gas heat exchanger WT50/60 Please read thoroughly prior to installation and maintenance. Summary About this manual This equipment

More information

User s Operation Instructions & Important Warranty Information

User s Operation Instructions & Important Warranty Information United Kingdom en User s Operation Instructions & Important Warranty Information High-efficiency wall-hung boilers Baxi Avanta Plus 18s - 24s - 30s 24c - 28c - 35c - 39c Please keep these instructions

More information

Baxi Maxflow Combi FS

Baxi Maxflow Combi FS Baxi Maxflow Combi FS Gas Fired Floor Standing Combination Boiler with Unvented Hot Water Storage Please keep these instructions safe. Should you move house, please hand them over to the next occupier.

More information

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions Electronically controlled instantaneous water heater MCX: 27300, 27400 and 27600 models Installation instructions These appliances deliver water not exceeding 50 ºC in accordance with AS3498. 1. Overview

More information

Logic+ Combi

Logic+ Combi USER GUIDE Logic+ Combi 24 30 35 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use

More information

UltraOil Condensing Oil Boiler

UltraOil Condensing Oil Boiler UltraOil Condensing Oil Boiler Responsibility for energy and environment Output range 35 to 600 kw Why choose UltraOil? The UltraOil condensing boiler featuring our patented alufer heat exchanger and two-stage

More information

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book USERS GUIDE Esprit eco 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification

More information

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user Electronically controlled instantaneous water heater MCX: 27300, 27400 and 27600 models Instructions for the user These appliances deliver water not exceeding 50 ºC in accordance with AS3498. 1. Overview

More information

INSTALLATION & SERVICE MANUAL

INSTALLATION & SERVICE MANUAL INSTALLATION & SERVICE MANUAL ELECTRIC WATER HEATER THE WARRANTY ON THIS WATER HEATER IS IN EFFECT ONLY WHEN THE WATER HEATER IS INSTALLED AND OPERATED IN ACCORDANCE WITH LOCAL CODES AND THESE INSTRUCTIONS.

More information

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND Aqua Balance AquaBalance TM CONTROL MODULE QUICK START GUIDE 10 1 Domestic Hot Water temperature setpoint decreasing button 2 Domestic Hot Water temperature setpoint increasing button 3 Central Heating

More information

HEAT & COOL MODEL (REVERSE CYCLE)

HEAT & COOL MODEL (REVERSE CYCLE) OPERATING MANUAL HEAT & COOL MODEL (REVERSE CYCLE) AIR CONDITIONER Duct Type Indoor Unit ARTG09LL ARTG12LL ARTG18LL KEEP THIS MANUAL FOR FUTURE REFERENCE P/N9374379439 CONTENTS SAFETY PRECAUTIONS... 1

More information

E-Combi One E-System ONE

E-Combi One E-System ONE discover more @ariston.com G.C.N.: 47-116-83 (24 kw) G.C.N.: 47-116-84 (30 kw) G.C.N.: 41-116-47 (24 kw) G.C.N.: 41-116-48 (30 kw) E-Combi One E-System ONE USER S MANUAL CONDENSING WALL-HUNG GAS BOILER

More information

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL Heating, Air Conditioning, Ventilation Отопление-Кондиционеры-Вентиляция MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL 1. Usage MTM 8-30 universal oil heater is designed for heating commercial rooms

More information

Baxi Maxflow Combi WM

Baxi Maxflow Combi WM Baxi Maxflow Combi WM Gas Fired Wall Mounted Combination Boiler with Unvented Hot Water Storage Please keep these instructions safe. Should you move house, please hand them over to the next occupier. User

More information

INSTALLATION AND MANINTENANCE INSTRUCTIONS

INSTALLATION AND MANINTENANCE INSTRUCTIONS INSTALLATION AND MANINTENANCE INSTRUCTIONS Appr. Nr. A 9503 T - 0085 AQ 0765 PEGASUS F2 T HIGH EFFICIENCY GAS-FIRED CAST-IRON BOILERS Models 51-68 - 85-102 2 Contents 1. General technical data 2. Dimensional

More information

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions Electronically controlled instantaneous water heater CEX 9-U: 27910-50 C models Installation instructions For 50 ºC models, the appliance delivers water not exceeding 50 ºC in accordance with AS3498. 1.

More information

User s Operation Instructions & Important Warranty Information. High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h

User s Operation Instructions & Important Warranty Information. High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h United Kingdom en User s Operation Instructions & Important Warranty Information High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h Please keep these instructions in a safe place.

More information

Maximiser SE. USER S INSTRUCTIONS Natural gas only INSTALLER: TELEPHONE:

Maximiser SE. USER S INSTRUCTIONS Natural gas only INSTALLER: TELEPHONE: Maximiser SE USER S INSTRUCTIONS Natural gas only INSTALLER: TELEPHONE: 705.276A-3233 11-2000 INTRODUCTION It is essential that the instructions in this booklet are strictly followed, for safe and economic

More information

GB24 & GB30. User Manual

GB24 & GB30. User Manual GB24 & GB30 User Manual BOILER OUTPUT To Domestic Hot Water:To Central Heating: GB24/30 Minimum 8.0 kw (27,296 Btu/h) GB24 Maximum 24.2 kw (82,570 Btu/h) GB30 Maximum 30.3 kw (103,384 Btu/h) GB24/30 Minimum

More information

Friwa Compact. Operating instructions EN

Friwa Compact. Operating instructions EN Operating instructions EN Version 1.1 / Edition 09/2013 Contents 1 Key background information... 3 1.1 Limitation of liability... 3 1.2 Responsibilities of the operator... 3 1.3 Documentation... 3 1.3.1

More information

ST9400A User Guide. Features

ST9400A User Guide. Features Features Easy to use slider and buttons combined with LoT Technology and an OK button, allows you to confi rm changes and stay in control. PLEASE RESPECT YOUR ENVIRONMENT! Take care to dispose of this

More information

VETO CLEANER 500 FLUE GAS CLEANER

VETO CLEANER 500 FLUE GAS CLEANER As of serial number 3100 0001 VETO CLEANER 500 FLUE GAS CLEANER USER MANUAL SPARE PARTS LIST Manufacturer: ALA TALKKARI Veljekset Ala-Talkkari Oy FI-62130 HELLANMAA TEL. +358 6 433 6333 FAX +358 6 437

More information

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER Combi C30 & C35 User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER When replacing any part on this appliance, use only spare parts that you can be assured confirm

More information

User & Installation instruction

User & Installation instruction LADDOMAT MR 40 User & Installation instruction Scope of delivery Valve package Laddomat 41-100 with: Charge and discharge valve with 2 non-return valves and thermal three-way valve. 2 pumps, LM6A-130.

More information

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber User Manual for model RBS 24 series ENERGY Wall mounted instantaneous combi boiler room sealed chamber CE 0694 RBS 24 - SERIE ENERGY - RAD - ING - MAN.UT - 1407.1 - DIGITECH TR - MIAH6 - E04 Technical

More information

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017 24 1 2 23 3 4 5 20 6 I 19 7 18 8 9 15 14 11 13 12 i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book i 24 OFF MAX E STATUS BURNER RESET MIN PRE MIN MAX HEAT PREHEAT

More information

Installation & Manual. Model T-25

Installation & Manual. Model T-25 Installation & Manual TR Central Heating Stove With Solid Fuel Model T-25 Tested according to DIN EN 13240 For product efficiency and emission values, see the declaration of conformity! TABLE OF CONTENTS

More information

Operating instructions

Operating instructions 6 720 804 891 2012/10 EN-US For the installer Operating instructions Sealed combustion boiler Logano GA124 SC If these instructions are not followed exactly, a fire or explosion may be caused with serious

More information

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM Thank you for choosing a DOMUSA TEKNIK heating boiler. Within the product range offered by DOMUSA TEKNIK you have chosen BioClass HM model. With a suitable

More information

General safety precautions English

General safety precautions English English 1 1 1.1 About the documentation The original documentation is written in English. All other languages are translations. The precautions described in this document cover very important topics, follow

More information

O P E R A T I N G I N S T R U C T I O N S

O P E R A T I N G I N S T R U C T I O N S O P E R A T I N G I N S T R U C T I O N S for Vertical Autoclave KSG 30/50-1 KSG 40/60-1 KSG 50/70-1 KSG 50/80-1 - single-walled execution - with sterilization timer and contact thermometer for sterilization

More information

about your house Assessing the Comfort and Safety of Your Home s Mechanical Systems

about your house Assessing the Comfort and Safety of Your Home s Mechanical Systems about your house CE 28 k Assessing the Comfort and Safety of Your Home s Mechanical Systems The heating, ventilating and air conditioning (HVAC) systems are a vital part of every home. These mechanical

More information

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions Performa Gas Fired Wall Mounted Combination Boiler User s Operating Instructions Please keep these instructions safe. Should you move house, please hand them over to the next occupier. Natural Gas Potterton

More information

User manual. Logano GC 124 II. Gas boiler

User manual. Logano GC 124 II. Gas boiler User manual Gas boiler WARNING! If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. B Do not store or use

More information

TopGas Cascade Condensing Gas Boilers Technical Information and Assembly Manual Output range 60 to 720 kw /17 Subject to modification

TopGas Cascade Condensing Gas Boilers Technical Information and Assembly Manual Output range 60 to 720 kw /17 Subject to modification TopGas Cascade Condensing Gas Boilers Technical Information and Assembly Manual Output range 60 to 720 kw Subject to modification Contents 1. Important Information 4 1.1. Documentation 4 1.2. Guarantee

More information

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers 5 YEAR WARRANTY ADVANCE PLUS High efficiency condensing combi and system boilers Android Apple WALL HUNG BOILERS Advance Plus ADVANCE PLUS HIGH EFFICIENCY BOILER RANGE The Advance Plus range is the latest

More information

Room-temperature (economy/night) unit TR 212 E

Room-temperature (economy/night) unit TR 212 E Room-temperature (economy/night) unit TR 212 E 7744 901 136 for boilers with Optimum Start-compatible Bosch Heatronic units Order no. 7 744 901 136 Contents Contents Safety instructions 3 Symbols 3 1 Details

More information

Avanta 24c - 28c - 35c - 39c 18s - 24s - 30s

Avanta 24c - 28c - 35c - 39c 18s - 24s - 30s Great Britain EN High-efficiency wall-hung boilers Avanta 24c - 28c - 35c - 39c 18s - 24s - 30s User s Operation Instructions & Important Warranty Information Please keep these instructions in a safe place.

More information