TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

Size: px
Start display at page:

Download "TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO"

Transcription

1 GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T-TWIN is characterized by having no additional moisture added to the supply air stream (indirect cooling). These coolers comprise four supply air fans, eight exhaust air fans, thirty two indirect heat exchanger core packs, two water reservoirs, two pumps, and two chlorinator systems. CABINET AND BASE FRAME The cabinet is constructed from 304 stainless steel incorporating the motor / fan assemblies, non-corrodible heat exchange cores and other ancillary equipment all supported by a heavy gauge galvanized base frame for structural stability. Fork lift tine channels are provided within the base frame to facilitate transport and lifting. Lifting chains / straps could also be used through these channels with appropriate lifting equipment onto elevated structures (e.g. roof of a building). Components are effectively treated to ensure corrosion resistance and mechanical fasteners are zinc coated steel and stainless steel as appropriate. Connection interface surfaces are provided for the outlet ductwork to the customer ductwork to enable fitment using established industry practices. FANS The fans are a multi blade, centrifugal type with backward curved blades and single inlet. They have black coated rotors and aluminium impellers and are individually statically and dynamically balanced. The fans are directly mounted to the electric motors. The electric motors are high efficiency, electronically commutated and speed controlled to optimise efficiency particularly at low speeds. HEAT EXCHANGE CORES The heat exchange cores are designed to facilitate heat exchange between the wet and dry air passages such that high efficiency heat transfer takes place without the addition of any moisture. They are designed to provide long life and long term high efficiency. ELECTRICAL CABINET AND CONTROLS At each end of the cooler, control equipment including motor control hardware, PLC control system, touch screen and other electrical equipment is pre-wired and factory mounted within a robust IP66 enclosure suitable for outdoor conditions. WATER DISTRIBUTION SYSTEM The water supply connection is a 316 stainless steel ½ BSPT (compatible with 1/2 NPT) fitting that connects to the internally mounted electrically operated water solenoid, at the end of each cooler. Heat exchange cores saturation is achieved through internally mounted pumps delivering water to a specially designed non-clog water distribution system providing continuous uniform flow. The wet components of each pump are manufactured from stainless steel and the pumps are driven by a 3 phase industrial, fully enclosed fan cooled electric motor with thermal overload protection. Easily cleanable in line strainers are provided for both the incoming water supply and the water distribution system. WATER MANAGEMENT SYSTEM The cooler includes an electronic water management system that controls the maximum salinity level of the reservoir water through continuous monitoring, draining and automatic replenishment as determined by the control system. AIR FILTER Intake air is filtered through easily accessible, washable and replaceable pleated filters. BMS INTERFACE A BACnet module (optional) provides full BACnet interface for control and monitoring of the cooler. Remote control of the cooler is possible via dedicated BMS terminals provided within the electrical cabinet. RESERVOIR The reservoir is constructed from polymer to ensure durability and corrosion resistance. The reservoir is designed to house the water pump and accommodate the level control, chlorinator system and salinity monitoring water management system. The design of the reservoir and watering system ensures that no water remains after draining. ILL2392-A 1 of 8 ES E127-C US1803

2 ELECTRICAL SYSTEM OVERVIEW (Times 2, at each end of the cooler except where stated) ILL2826-A ILL2255-A WATER CONNECTION 1/2 BSPT Male thread (compatible with 1/2 NPT) connection on cooler, at each end of the cooler. Water Supply Temperature: Max. 104 F In areas subject to freezing, the water line needs a drain down facility. If the water pressure exceeds the maximum specification then a pressure reducing valve is required and must be supplied and fitted by the installer. ILL2356-A DRAIN CONNECTION A built-in Drain Valve is controlled by the Water Management System. Drain water and tank overflow water must be carried away to a suitable discharge point in accordance with local regulations. The drain outlet provided will accept an NPS 2 inch PVC pipe. Direct water into an open drain. 2 of 8 ES E127-C US1803

3 BACNET INTERFACE OPTIONS FOR CW-80 SERIES BACnet is currently offered as an option on all CW-80 Series coolers. The popular protocols BACnet/IP and BACnet MS/TP can be provided as well as BACnet Ethernet. For the CW-80T-TWIN cooler, there are two instances of the interfaces described below and BACnet field wiring connections (with unique IP addresses) are required at each end of the cooler. Under BACnet control, it is recommended to operate both halves of the cooler in tandem. Communication items (referred to as objects ) form the key to the BACnet system. Seeley International have developed a full set of 108 objects for the CW-80 Series range of coolers. This set of objects (referred to as an objects list ) is detailed in the cooler Installation and Operation Manual BACnet Object List CW-80 Series and is available to assist customers in designing their building management control systems. This objects list can be divided into two groups - 17 objects that can be both read and modified by the customer and the balance of 91 objects that can be read only. The first group of 17 modifiable objects are associated with controlling and operating the CW-80 Series cooler as summarized in the following table: - Item Objects Details basic control 6 control of BACnet active, run, cool, direct cool (supercool only), fan speed, water tank drain master error reset 2 ability to reset errors clock 8 provision for adjusting clock - daylight saving BACnet integrity 1 used to confirm BACnet signal integrity (selectable feature) The second group of 91 read only objects are associated with the status of the CW-80 Series cooler as summarized in the following table: - Item Objects Details basic 19 software number, version and date, control mode, current operating status, watering sequence control, commissioning mode BMS 7 status of standard hard wired BMS signals air temperatures and humdity 8 air temperatures in both deg C and deg F for ambient, intermediate (supercool only) and supply air humidity in RH% for ambient and supply air pressures 4 differential pressure across the supply and exhaust parts of the core in both Pa and inches of water fans 10 supply and exhaust fan speeds, enable signals, normal signals tank 9 status of tank water level sensors, inlet solenoid, drain valve, chlorinator enable and adequate voltage output, average tank refill time, drain delay elapsed period Item Objects Details watering system 2 operating status of indirect pump and direct (supercool only) pump salinity 2 status of high salinity signal and timed drain in progress hours 6 accumulated running time in hours for overall cooler, supply fans, exhaust fans, indirect pump, direct pump (supercool only), chlorinator errors 24 water supply poor or inadequate at various stages of the tank fill or refill, indirect pump overload, direct pump (supercool only) overload, supply fan errors, exhaust fan errors, chlorinator warning and critical errors, high inlet air filter differential pressure error, low exhaust pressure error, unit operating in forced vent mode or has shut down due to combination of errors With the BACnet option installed, the standard BMS interface is still available should this be required. In this scenario the customer would control the cooler using the standard BMS interface but at the same time utilise the BACnet system only to monitor the detailed status of the cooler. A specific BACnet object is provided so that the customer can freely select either this style of control or normal full BACnet control. BACnet field wiring is simple as only a single pair of shielded wires is required to be connected to two terminals. Further, in multiple cooler installations this wiring can be looped from one cooler to the next up to a maximum of 127 coolers whilst still maintaining individual control and status monitoring. 3 of 8 ES E127-C US1803

4 TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO ISO PLUMBING DOOR SWING ILL2536-A ILL2392-A Option: Attenuator Ready Exhaust Ducts replacing Weatherseals TOP ILL2309-A FRONT & REAR CONTROL PANEL ILL2393-A SIDE ILL2309-B 2-3/16" 1' 3-9/16" WATER INLET ILL2395-A 4 of 8 2' 9-29/32" 3' 5-7/8" DRAIN ILL2389-A ES E127-C US1803 ILL2564-A

5 SPECIFICATION Services Environment Performance Supply Motors/Fans Exhaust Motors/Fans Electrical Supply Water Supply Max. Operating Temp High Speed Standard High Capacity option Standard High Capacity option Nominal cooling capacity BTU/h (* Aus standard KW ) Diecast aluminium housing. Inverter drive with 0-10V control and overload protection. Diecast aluminium housing. Inverter drive with 0-10 V control and overload protection CW-80T-TWIN 3-phase +E, V 60Hz Rated 40A (total) FLA 46A, MCA 53.1A, MOPD 55A 3-phase +E, V 60Hz Rated 50A (total) FLA 56.8A, MCA 65.5, MOPD 70A 1/2 male BSPT (compatible with NPT) connection. Recommended pressure range 30 to 70 psi. Maximum pressure (static) 120 psi Minimum flow rate through 13/32 inch test orifice: 12 US gal/min * Cooling capacity measured to Australian Standard AS , ambient of F dry bulb & F wet bulb, with room exit temperature of F. Or Minimum pressure measured at connection point whilst simultaneously delivering 12 US gal/min: 12 psi 131 deg F ambient (measured in shade) Supply - 27, inches of water Exhaust - 22,200 cfm Supply - 27, inches of water Exhaust - 22,200 cfm 410,200 BTU/h, 67.6 deg F) supply temp, stand-alone cooling 978,600 BTU/h, pre-cooling outside air V 50 / 60Hz 4 fans / motors, 22" dia V 50 / 60Hz 8 fans / motors, 14" dia Supply Air Outlet Top discharge, vertical duct /8 x 3' 3-3/8" IP55 304/316 Stainless Steel wet end construction Pumps - (Indirect) 0.75kW 3 phase 50 / 60 Hz (2 off) IP55 304/316 Stainless Steel wet end construction Pump - (Direct) nil Chlorinator Controller and Cells 220V 60Hz (2 off) Salinity Salinity Water Manager (2 off) Seeley International P/Ltd Management Water Probe (2 off) Seeley International P/Ltd Drain Valves low voltage, vertical, electric servo motor drive 24VAC, P/No (2 off) Drain Connection Water Reservoir Heat Exchange Core Shipping Supplied horizontal outlet accepts 2.375" OD PVC pressure water pipe Seeley International P/Ltd moulded polymer Seeley International P/Ltd synthetic plate type, super efficient Dimensions Weight NPS 2 inch PVC 2 connections, one at each end 96 US gals capacity 2 48 US gals capacity each Total 32 cores /8 L* /16 W * 8 4-1/4 H total for 2 units end to end (each unit /32 L* /16 W * 8 4-1/4 H) total 8,616 lb (two units, each weighing 4308 lb) Operating Weight Weight including reservoir water, system water, supply and exhaust stator ducts. total 11,706 lb (two units, each weighing 5853 lb) Air Filtration MERV 7 (G4) washable filters (standard) Nominal 25 x 25 x 2 deep Standards Compliance All mains voltage electrical components UL listed. Cooler complies to AS / IEC / EN Sound Power Level (without High Capacity option) (Based on a singular CW-80T or a CW-80) Radiated Power in horizontal direction with supply duct connected (db re 1pw) Octave Band Centre Frequency (HZ) k 2k 4k 8k Total Sound Power Level (dba re 1pw) of 8 ES E127-C US1803

6 CW-80T-TWIN STANDARD USA & MEXICO ILL2824-A STATIC PRESSURE (iwg) Airflow 80% De-rate 28,940 27,920 26,960 26,060 25,180 Airflow 90% De-rate 30,300 29,840 29,320 28,640 27,920 CW-80T-TWIN HICAP USA & MEXICO ILL2825-A STATIC PRESSURE (iwg) Airflow 85% De-rate 31,360 29,120 27,240 25,340 6 of 8 ES E127-C US1803

7 NOTES: THIS PAGE LEFT INTENTIONALLY BLANK 7 of 8 ES E127-C US1803

8 NOTES: THIS PAGE LEFT INTENTIONALLY BLANK 8 of 8 ES E127-C US1803

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T-TWIN is characterized by having no additional moisture

More information

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T is characterized by having no additional moisture added

More information

Indirect Evaporative Air Conditioning

Indirect Evaporative Air Conditioning Indirect Evaporative Air Conditioning World leading climate control solutions Seeley International is Australia s largest air conditioning manufacturer and a global leader in developing ingenious, energy-efficient

More information

Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160)

Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160) Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160) About Climate Wizard Climate Wizard s unique indirect evaporative heat exchange core provides hyper-efficient cooling of outside air.

More information

FACTORY INSTALLATION (CW-160) Indirect evaporative air conditioner 100% outside air

FACTORY INSTALLATION (CW-160) Indirect evaporative air conditioner 100% outside air FACTORY INSTALLATION (CW-160) Indirect evaporative air conditioner 100% outside air About Climate Wizard Climate Wizard is an air conditioner that uses an indirect evaporative heat transfer core that provides

More information

Indirect Evaporative Air Conditioning

Indirect Evaporative Air Conditioning Indirect Evaporative Air Conditioning World leading climate control solutions Seeley International is Australia s largest air conditioning manufacturer and a global leader in developing ingenious, energy-efficient

More information

FACTORY INSTALLATION (CW-160) Indirect evaporative air conditioner 100% outside air

FACTORY INSTALLATION (CW-160) Indirect evaporative air conditioner 100% outside air FACTORY INSTALLATION (CW-160) Indirect evaporative air conditioner 100% outside air About Climate Wizard Climate Wizard is an air conditioner that uses an indirect evaporative heat transfer core that provides

More information

KOMFORT EC DB Suspended heat recovery air handling units

KOMFORT EC DB Suspended heat recovery air handling units 2018 AIR HANDLING UNITS KOMFORT EC DB Suspended heat recovery air handling units Features Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings.

More information

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S Heat and Energy Recovery Ventilators 2018 AIR HANDLING UNITS 2 CONTENT KOMFORT EC S5B270(-E) 4 KOMFORT EC D5B1(-E) 8 KOMFORT EC S(B)(-E) 12 AIR HANDLING UNITS

More information

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw COOLROW Close control air conditioners for In-Row installation Cooling Capacity: 14 61 Available in versions equipped with: - BLDC inverter scroll compressor on board of the unit - Chilled water feeding

More information

Product Data. Features/Benefits. AIRSTREAM 42WKN08-36 Hydronic Ceiling Cassettes

Product Data. Features/Benefits. AIRSTREAM 42WKN08-36 Hydronic Ceiling Cassettes Product Data AIRSTREAM 42WKN08-36 Hydronic Ceiling Cassettes 3 / 4 to 3 Nominal Tons a42-4013 a42-4014 UNIT SIZES 08-12 UNIT SIZES 18-36 Hydronic ceiling cassette units offer: 6 chilled water cooling models

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...

More information

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units TECHNICAL SPECIFICATIONS R7DA Series 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units 5.4 ISMRE Commercial System 81% Steady State Efficiency Standard Features Fits Pre-Existing Curbs High-Efficiency Low

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT... 3 Performance Data... 4 Performance Table... 5 General description... 6 Fan Chart-explanation

More information

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 % Single-room heat recovery unit Air flow up to 59 CFM Heat recovery efficiency up to 96 % 2018 SINGLE-ROOM HEAT RECOVERY UNITS Features Efficient solution for supply and exhaust ventilation of enclosed

More information

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB 4,5 22,5 kw Air-conditioned server-racks for direct installation into the room technicalcatalogue T_CLSEVO_0113_GB INDEX HIGHLIGHTS... 3 PLANT TYPE... 3 GENERAL CHARACTERISTICS... 5 SERIES IDENTIFICATION...

More information

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС HEAT RECOVERY AIR HANDLING UNITS Series VUT R TN H ЕС VUT R TN EH ЕС HEAT-RECOVERY VENTILATION Two-Stage Energy Saving System: HEATING COOLING Stage 1: Heat energy recovery by means of the rotary heat

More information

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning : Direct expansion close control air conditioners with up-flow or down-flow air delivery. Cooling Capacity: 7 102 NEW SOFTWARE R410A rcgroupairconditioning E C A C UP FLOW DOWN FLOW MAIN FEATURES Precision

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

System Floor Mount Systems DX / Glycol / Chilled Water 6-12 Tons. High Density Presicion Cooling. Kompact.

System Floor Mount Systems DX / Glycol / Chilled Water 6-12 Tons. High Density Presicion Cooling. Kompact. High Density Presicion Cooling Floor Mount Systems DX / Glycol / Chilled Water 6-12 Tons System 2100 Kompact www.compu-aire.com CA A - 8 34 -K System 2100 K Type Air Cooled - A Chilled Water Cooled - C

More information

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with

More information

TopVent Design Handbook

TopVent Design Handbook TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit

More information

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions Dehumidifiers for radiant cooling systems with heat recovery 50 The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium

More information

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB Next P 6 112 kw COOLING 5 93 kw HEATING Heat pump air conditioners with upflow air delivery technicalcatalogue T_NXTP_0411_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 4 MODEL IDENTIFICATION...

More information

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION 100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental TECAM S.A. Tecnología Ambiental R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz harmony 5PZA Direct Expansion Registration No.: SC 4696-1 Registration No.: CO-SC 4696-1 Air Conditioning Equipment Manufacturer

More information

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique

More information

MiniCore Ventilator (500, 1000) Series Engineering Guide

MiniCore Ventilator (500, 1000) Series Engineering Guide MiniCore Ventilator (500, 1000) Series Engineering Guide November 2017 V1.0 Johnson Controls, Inc. All rights reserved. TABLE OF CONTENTS Page Functionality and Benefits... 1 Unit Overview... 3 MiniCore

More information

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini... Contents How to choose Recovery Ventilation type?............................................3 How do HRV, ERV and TRV Systems work?............................................4 Types of installations..............................................................5

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

SEQUENCE OF OPERATIONS

SEQUENCE OF OPERATIONS SEQUENCE OF OPERATIONS DDC CONTROLLER: Controller with integral LCD readout for changing set points and monitoring unit operation. Provided with required sensors and programming. Factory programmed, mounted,

More information

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01

More information

TABLE OF CONTENTS INTRODUCTION NOMENCLATURE AC P S J 035 C CO AR Q - 2 -

TABLE OF CONTENTS INTRODUCTION NOMENCLATURE AC P S J 035 C CO AR Q - 2 - TABLE OF CONTENTS Page No Introduction... 2 Nomenclature... 2 Components... 3 Standard Features... 3 Optional Accessories... 5 Cooling and Heating Portfolio... 5 Physical Specifications... 6 System Cooling

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

MODEL TRC TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS

MODEL TRC TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS MODEL FTURES MERV-8 filters Transformer/relay package allowing simple on/off control Access doors for easy access to blowers, core and filters

More information

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS. PRODUCT SPECIFICATIONS INDOOR AIR QUALITY HCWHD Healthy Climate Whole-Home Dehumidifier Bulletin No. 210699 November 2017 Supersedes April 2017 MODEL NUMBER IDENTIFICATION Nominal Capacity - 70 to 130

More information

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES 60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,

More information

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127. Product Data GEMINI 38AKS028-044 Commercial Air-Cooled Split Systems 50/60 Hz 25 to 40 Nominal Tons (82.8 to 127.0 kw) These dependable split systems match Carrier s indoor-air handlers with outdoor condensing

More information

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater SUPPLY UNITS Series VENTS PA E Series VENTS PA W A13 control panel A13 control panel Suspended air supply units with the air capacity up to 3350 m 3 /h in the sound- and heat-insulated casing with the

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be

More information

BOOK 2 SPECIFICATIONS

BOOK 2 SPECIFICATIONS 4510 Helgesen Drive, Madison, WI, 53718 608.221.4499, 800.627.4499, Fax: 608.221.2824 support@renewaire.com www.renewaire.com RD2XIN INSTALLATION AND OPERATION MANUAL BOOK 2 SPECIFICATIONS This book provides

More information

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR

More information

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs next generation C precision controlled industrial process chillers cooling capacity: 6824 -,255,668 BTU /hr (0.6-04.6 tons) cooling capacity: 6,824 -,254,303 BTU/hr (0.6-04.5 tons) precision controlled

More information

Specification Data. General:

Specification Data. General: Specification Data General: Zone Units (ACU s) will be draw through vertical type having double skin construction. All Zone Units will have all necessary components such as control valves and motors to

More information

CAREL heatersteam Electric Element Steam Humidifiers

CAREL heatersteam Electric Element Steam Humidifiers Suggested Engineering Specifications Section 23 84 13 CAREL heatersteam Electric Element Steam Humidifiers 1. GENERAL SCOPE 1. Furnish and install as indicated on the drawings and plans, in-duct [space]

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

EnviroMagic. Low profile, ultra-high efficiency evaporative cooling for commercial and industrial applications

EnviroMagic. Low profile, ultra-high efficiency evaporative cooling for commercial and industrial applications EnviroMagic Low profile, ultra-high efficiency evaporative cooling for commercial and industrial applications World leading climate control solutions Seeley International is Australia s largest air conditioning

More information

EHH SERIES DRAW THROUGH FAN COILS CFM

EHH SERIES DRAW THROUGH FAN COILS CFM EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE

More information

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons Product Data 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes 2to4NominalTons The 40QK Energy-Efficient In Ceiling Cassette fan coil incorporates innovative technology to provide

More information

7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh. One of a kind design from the inside, out!

7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh. One of a kind design from the inside, out! Advanced Heating and Hot Water Systems High Efficiency Fire Tube Heating Boiler 7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh up to 97% Efficient 5:1 Turndown Ratio One of

More information

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000

More information

Energy Recovery with Cooling and Heating Model ERCH

Energy Recovery with Cooling and Heating Model ERCH Energy Recovery with Cooling and Heating Model ERCH 100% Outdoor Air System Dedicated Outdoor Air System 1,000-10,000 cfm 1.75 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating,

More information

Sentinel Demand Energy Recovery Ventilation

Sentinel Demand Energy Recovery Ventilation Welcome to the world of Sentinel Demand Energy Recovery Ventilation Sentinel Totus 2 Demand Energy Recovery Ventilation (D-ERV) is a new heat recovery demand ventilation system designed to meet modern

More information

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton EP Water Source Heat Pump ½ to 6 Ton Industry-leading single-stage efficiencies, standard features, and a variety of options - providing energy efficient solutions to accommodate your building requirements.

More information

Submittal Data Performance Data Electrical Data

Submittal Data Performance Data Electrical Data ERMS Series Submittal Data Submittal Data Unit Designation: Job name: Architect: Engineer: Contractor: Performance Data Revision: 07/01/11 Cooling Capacity: EER: Heating Capacity: COP: Ambient Air Temp:

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1 TVR 5G GUIDE SPECS TVR 5G GUIDE SPECS - JUL.2014 Page 1 Part 1 TRANE VARIABLE REFRIGERANT FLOW SYSTEM 1.1 General PRODUCT Unit shall be air cooled variable refrigerant flow system, module split type multi-system

More information

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY Product Overview www.orcaenergy.eu MAXI Device for heat recovery MAXI is designed to provide permanent controlled air exchange by means of mechanical ventilation

More information

GHE Dehumidifiers for radiant cooling systems with heat recovery

GHE Dehumidifiers for radiant cooling systems with heat recovery Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

Precise Temperature Control; Compact Footprint

Precise Temperature Control; Compact Footprint Precise Temperature Control; Compact Footprint The Conair EP1 Series Portable Chillers are designed for 1 to 3 ton applications. Available as air-cooled or water-cooled, with pump sizes from 1/4 to 3 Hp

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED

More information

Samsung 360 Cassette, Single Zone, Split System

Samsung 360 Cassette, Single Zone, Split System Job Name Purchaser Submitted to Unit Designation Location Engineer Reference Schedule # Approval Page 1 of 5 Construction Specifications Model Indoor Unit Model Number Outdoor Unit Model Number Nominal

More information

Project Name: Location: Engineer: Contractor: I. GENERAL

Project Name: Location: Engineer: Contractor: I. GENERAL Part I - General Part II - Product Part III - Installation Project Name: Location: Engineer: Contractor: I. GENERAL I. PRODUCT Rep: Date: A. Supply and install modulating and condensing boiler(s) as specified

More information

OWNER S MANUAL. Evaporative Cooler. Original English Instructions. (English) (LCB, CPL, CPS, BM)

OWNER S MANUAL. Evaporative Cooler. Original English Instructions. (English) (LCB, CPL, CPS, BM) OWNER S MANUAL Evaporative Cooler (English) (LCB, CPL, CPS, BM) Original English Instructions TABLE OF CONTENTS INTRODUCTION 4 WALL CONTROL FUNCTIONS 5 STARTING YOUR COOLER 5 AUTOMATIC MODE 6 MANUAL MODE

More information

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified Data Aire LCS TM (Large Ceiling System) 6, 8, 10, and 13 ton ISO 9001 Certified LCS TM (LARGE CEILING SYSTEMS) DX Product Description Performance and Electrical Data 3 the pioneer and builder of the most

More information

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled FORM 145.05-EG1 (1004) VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU 10 105 Ton Water-Cooled Table of Contents FORM 145.05-EG1 (0804) Features and Benefits.....................................................

More information

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS Cooling Capacity from 115,000 to 670,000 Btu/hr Btu/hr Smartwise Innovations... Towards Green, Quality & Reliability Solutions SERIES INTRODUCTION

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

CoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor

CoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor CoolTeg Plus XC40 AC-TXC Direct expansion Air-conditioning unit with integrated compressor Application CoolTeg Plus XC40 is a revolutionary air-conditioning unit specifically designed for installation

More information

NQ Series Portable Chillers

NQ Series Portable Chillers NQ Series Portable Chillers Electrical Components Mounted and Wired All electrical components and sensors are mounted, wired, and fully tested at the factory to reduce installation time and ensure the

More information

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps Product Data OMNIZONE 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps 18 to 60 Nominal Tons omnizonebwlogo 50BVC,E,J,K,Q020-034 SINGLE PIECE OMNIZONE

More information

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging Ducted Three Phase Packaged Air Conditioners Technical Data, 340, 370 Twin System Enables Staging Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 29.5 kw 34.0 kw 39.1 kw OCTOBER 2013

More information

CONDENSING HIGH EFFICIENCY BOILERS

CONDENSING HIGH EFFICIENCY BOILERS Built by 3I Innovative Industrial Inc. ABS Series CONDENSING HIGH EFFICIENCY BOILERS ABS 1500-2000-2500-3000-4000MBH Cast aluminum heat exchanger 10 to 1 turndown ratio Honeywell Sola boiler control system

More information

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems Models: ACC 75D/DR ACC 100D/DR ACC - D2-2007 (Draft) Ceiling Concealed Split Systems CONTENTS 1. NOMENECLATURE... 2 2. FEATURES... 4 3. PRODUCT LINE UP... 5 4. SPECIFICATIONS... 8 5. OPERATING RANGE...

More information

GP SERIES Packaged Chillers

GP SERIES Packaged Chillers Material Handling Process Cooling Temperature Control Size Reduction Temperature Control Process Cooling Material Handling Size Reduction GP SERIES Packaged Chillers Precision Comprehensive Engineered

More information

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make. All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing

More information

NFZP Variable Refrigerant Flow Guide Specification

NFZP Variable Refrigerant Flow Guide Specification PART 1 - GENERAL 1.01 SECTION INCLUDES SECTION 23 81 29 VARIABLE REFRIGERANT FLOW HVAC SYSTEM A. (VRF) HVAC system includes: 1. Outdoor/Condensing unit(s): a. Size Range: 14 Tons Nominal b. YANMAR VRF

More information

Liebert Mini-Mate2. 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz. Technical Data Manual

Liebert Mini-Mate2. 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz. Technical Data Manual Liebert Mini-Mate2 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz Technical Data Manual Technical Support Site If you encounter any installation or operational issues with

More information

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units

More information

FCC Fan-Coil Units High-Performance, Vertical

FCC Fan-Coil Units High-Performance, Vertical FCC Fan-Coil s High-Performance, Vertical Model FCC construction features Piping and supply-duct connections are from top of unit, eliminating the need for side or back access Right or left-hand configurations

More information

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating Rooftop Ventilator with Packaged Cooling & Heating Models RV and RVE Institutional Commercial Industrial 800-1,500 cfm.0 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating Packaged

More information

Guide Specifications PART 1 GENERAL 1.01 SUMMARY

Guide Specifications PART 1 GENERAL 1.01 SUMMARY Guide Specifications PART 1 GENERAL 1.01 SUMMARY A The environmental control system shall be designed specifically for precision temperature control applications. It will automatically monitor and control

More information

The EnduroTi HIGH MASS. Superior Construction: COMMERCIAL CONDENSING BOILER. Stainless Steel Titanium Blend. 10 : 1 Turndown Ratio

The EnduroTi HIGH MASS. Superior Construction: COMMERCIAL CONDENSING BOILER. Stainless Steel Titanium Blend. 10 : 1 Turndown Ratio The EnduroTi COMMERCIAL CONDENSING BOILER Advanced Heating & Hot Water Systems Superior Construction: Stainless Steel Titanium Blend HIGH MASS Stainless Steel AISI 316 Ti Manufactured out of this extremely

More information

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS enthalpy membrane in the warm season. This allows for a considerable reduction of the supply air temperature and humidity which, in turn, reduces the

More information

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center Uniflair LE TDER-TUER Energy-saving units with backward-curved fans 20-100kW > Perimeter cooling for medium/large data center > Refrigerant R-410A Available Versions: > Downflow (TDER) > Upflow (TUER)

More information

ELECTRICAL QUANTITY WEIGHT (LB)

ELECTRICAL QUANTITY WEIGHT (LB) VRF SYSTEM INDOOR UNIT ENTERING AIR TEMPERATURES ( F) CAPACITIES (kbtuh) Max SOUND ELECTRICAL WEIGHT TOSHIBA-CARRIER COOLING HEATING Airflow PRESSURE, MARK NO. TYPE ROOM TOTAL SENSIBLE HEATING V / Ø /

More information

Remote Air Cooled Condensers C2 Series

Remote Air Cooled Condensers C2 Series Remote Air Cooled Condensers C2 Series High Fan Speed Capacity 236kW Low Fan Speed Capacity 1740kW 180kW 1257kW Innovative Heat Transfer Solutions Issue date 04/14 APPLICATION BENEFITS / FEATURES HIGH

More information

When reliability is vital. Alemite Carbon Shield TM Systems deliver

When reliability is vital. Alemite Carbon Shield TM Systems deliver CATALOG 2 When reliability is vital. Alemite Carbon Shield TM Systems deliver Atomized Oil Lubrication system for rotating machinery bearings, gears and chains. Proven in refineries, petro-chem plants,

More information

NEXT DL NEXT DL. rcgroupairconditioning

NEXT DL NEXT DL. rcgroupairconditioning NEXT DL: Close control air conditioners with displacement air delivery with remote condenser, or built in water cooled condenser or for chilled water feeding Cooling capacity: 7,7 51,4 NEXT DL rcgroupairconditioning

More information

VERSO Air Handling Units

VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P air handling units equipped with recuperation system

More information