1

2 Contents How to choose Recovery Ventilation type? How do HRV, ERV and TRV Systems work? Types of installations Centralized Recovery Ventilators VUT 200 H mini Brig HRV 120, Brig HRV 200, Frigate HRV 60S, ERV 60S Frigate HRV 120S, ERV 120S Frigate HRV 100DS, ERV 100DS, TRV 100DS, HRV 1DS, ERV 1DS, TRV 1DS Decentralised Recovery Ventilators TwinFresh S-60, S TwinFresh R-, R MICRA Optional remote controls Quick Selection Table VENTS. Air handling units

3 VentsUS.com Select the correct Recovery Ventilation type (Heat Recovery Ventilation) HRV IIf you use a heating system more often than air conditioning, you need an HRV. Heat recovery systems have been designed to recover the heat contained in the extract air. Heat energy Latent energy (humidity) ERV (Energy Recovery Ventilation) If you use air conditioning more often than heating, an ERV is recommended. The enthalpic core of the ERV transfers heat and moisture from the intake air to the extract air. The air brought into the living area is cooled and the humidity is reduced for maximum comfort. The load on your air conditioner drops and you save on cooling costs. TRV (Twin Recovery Ventilation) TRV has the benefits of both HRV and ERV. You save heating in winter and air conditioning costs in summer. Moreover, you enjoy air with balanced humidity for maximum comfort. Select the ventilator model If your home is up to: Area of house Sq. Ft. HRV ERV TRV S 60S DS 100DS 100DS VUT 200 mini, , 120S 120S S 1S 1DS What is the difference? HRV Heat transfer Frostproof core Energy efficient rate ERV Heat transfer Humidity transfer Over dry and moisture damage prevention More energy efficient rate vs. HRV TRV Heat transfer Humidity transfer Over dry and moisture damage prevention Frostproof core Most energy efficient rate vs. HRV&ERV Aluminum or plastic core Enthalpic core Aluminum & Enthalpic core Fits to cold climate area Fits to hot and humid climate areas Fits to all climate areas Improve indoor air quality Provide fresh air Pre-heat intake air in winter time Pre-cool intake air in summer time Save on heating & air conditioning costs Washable filters Deliver fresh outdoor air Drives out harmful indoor pollutants VENTS. Air handling units

4 How do HRV, ERV and TRV Systems work? HRV (Heat Recovery Ventilation) The fresh incoming air absorbs the heat from the air being extracted. This fresh warm air is then circulated back into the home or building. Intake air Extract air Dust, CO 2 and other pollutants Humidity Heat Energy Exhaust Air Static Plate (Plastic or metal) Recovery Heat Energy Outside Air Supply air Exhaust air Condensed Moisture Drain Pan ERV (Energy Recovery Ventilation) In the winter months the core captures the humidity of the extract air and circulates it back into the home or building. In summer the humidity is captured and exhausted outside. No drain pan is required. Intake air Extract air Supply air Dust, CO 2 and other pollutants Humidity Heat Energy Exhaust Air Static Plate (Paper) Recovery Heat Energy Return Humidity Outside Air Exhaust air TRV (Twin Recovery Ventilation) Drain Pan is not needed! Contains both HRV and ERV recovery cores inside. Both HRV and ERV cores of the Twin Recovery Ventilators provide "sensible" heat transfer. The HRV core makes Twin Recovery Ventilators suitable for cold climate zones and the ERV core increases the unit s efficiency by extra moisture transfer. Intake air Exhaust air Supply air Extract air 4 VENTS. Air handling units

5 VentsUS.com Types of installation Independent System installation In this application the ductworks are used to supply fresh air to bedrooms and living areas and extract stale air from the bathroom, kitchen and laundry room. Exhaust at the source and supply in the return This application uses a separate duct system to extract air from the bathroom, kitchen and laundry room. The fresh air is dumped into the return air duct of the forced air system and is distributed in the house together with supply air. Exhaust and supply combined VENTS. Air handling units

6 Centralized Recovery Ventilators VUT 200 H mini A Heat Recovery Ventilator is a complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of contaminated air. The HRV ventilators utilize the sensible energy in the heat recovery core. The special polymer core transfers heat from the extract air stream to the intake air stream so you save on energy costs. Features Efficient recovery ventilation Cross flow core with recuperation efficiency up to 80% Silent operation Replaceable filters Simple installation and maintenance Compact size Defrost system Casing Steel casing is covered with high-quality multilayer aluminium and zinc alloy to prevent corrosion. The casing is equipped with a switch to turn the ventilator off when the service panel is opened. Filter Washable G4 air filters in exhaust and supply air streams. Heat recovery core Specially designed aluminum plate core ensures excellent heat recovery efficiency. Whenever heat recovery is not required, the heat recovery block can be easily replaced by a "summer" block. The ventilator is also equipped with a drain pan for condensate drainage. Defrost system To protect the heat recovery core, the freezing electronic protection system is applied. It switches the supply fan off as the temperature sensor requires. Warm extract air defrosts the heat recovery core, then the supply fan switches on and the ventilator continues operating under rated conditions. Motors German made high-efficient motor combined with backward inclined impeller delivers exceptionally powerful airflow and high static pressure. Built-in Thermal Overheating Protection with Automatic Restart makes the motor operation secure and reliable. Permanently lubricated ball bearings inside the motor provide long (40000 hours) trouble- and maintenance-free operation. Fans The ventilator is equipped with supply and exhaust centrifugal fans with backward inclined blades and built-in thermal overheating protection with automatic restart. The electric motors and the impellers are dynamically balanced in two planes. Control The ventilator comes with a thyristor speed control. Mounting The unit can be mounted in most positions and in most spaces. Please refer to installation manual for instructions and details. Warranty 5 year warranty Extract air Intake air Supply air Exhaust air 6 VENTS. Air handling units

7 VentsUS.com Performance VUT 200 H mini Volts 120V, 60Hz Max. Max. Amps RPM Airflow CFM 0" 0,125" 0,25" 0,5" 0,75" 1.0" 1.25" 1.5" Heat recovery core efficiency, % < 80% 4'' Duct Dia. Flow Rate, [L/s] Static Pressure [in. WG] VUT 200 mini Static Pressure [Pa] Flow Rate, [CFM] Dimensions Accessories 10 15/ /16 Ø 4" Air disk valve 23 5/8 Backdraft Dampers Clamps VENTS. Air handling units

8 Brig HRV 120, 170 A Heat Recovery Ventilator is a complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of stale air. Features Efficient recovery ventilation Cross flow core with recuperation efficiency up to 80% Silent operation Replaceable filters Simple installation and maintenance Compact size Defrost system Casing Steel casing is covered with high-quality multilayer aluminium and zinc alloy to prevent corrosion. The casing is equipped with a switch to turn the ventilator off when the service panel is opened. Filter Washable G4 air filters in exhaust and supply air streams. Optional supply: anti grease filter. Heat recovery core Specially designed polymer plate core ensures excellent heat recovery efficiency. Whenever heat recovery is not required, the heat recovery block can be easily replaced by a "summer" block. The ventilator is also equipped with a drain pan for condensate drainage. Defrost system To protect the heat recovery core, the freezing electronic protection system is applied. It switches the supply fan off as the temperature sensor requires. Warm extract air defrosts the heat recovery core, then the supply fan switches on and the ventilator continues operating under rated conditions. Motors German made high-efficient motor combined with backward inclined impeller delivers exceptionally powerful airflow and high static pressure. Built-in thermal overheating protection with automatic restart makes the motor operation secure and reliable. Permanently lubricated ball bearings inside the motor provide long (40000 hours) trouble- and maintenance-free operation. Fans The ventilator is equipped with supply and exhaust centrifugal fans with backward inclined blades and built-in thermal overheating protection with automatic restart. The electric motors and the impellers are dynamically balanced in two planes. Control The ventilator is equipped with 3-step switch on it's side panel to choose STANDBY, LOW or MEDIUM mode for continuous operation. The unit can be equipped with wide range of additional controls (page 24) to switch boost on demand. Mounting The unit can be mounted in most positions and in most spaces. Please refer to installation manual for instructions and details. Warranty 5 year warranty Extract air Intake air Supply air Exhaust air 8 VENTS. Air handling units

9 VentsUS.com Performance HRV 120 HRV 170 Volts 120V, 60Hz 120V, 60Hz Max. Max. Amps RPM 0,1" (25Pa) (84) (91) 0,2" (Pa) 160 (76) 178 (84) 0,3" (75Pa) 147 (69) 167 (79) 0,4" (100Pa) 131 (62) 153 (72) 0,5" (125Pa) 118 (56) 143 (67) Airflow CFM (L/s) 0,6" (1Pa) 105 () 133 (63) 0,7" (175Pa) 92 (43) 123 (58) 0,8" (200Pa) 77 (36) 113 (53) 0,9" (225Pa) 62 (29) 103 (49) 1,0" (2Pa) 45 (21) 91 (43) 1,2" (300Pa) (33) 1,4" (3Pa) (19) Heat recovery core efficiency, % Duct Dia. < 80% 6'' < 80% 6'' Sensible efficiency(%) at 56 cfm 80 cfm 160 cfm 120 cfm HRV Sensible efficiency(%) at 62 cfm 89 cfm 178 cfm 133 cfm HRV Flow Rate, [L/s] Flow Rate, [L/s] Static Pressure [in. WG] HRV Static Pressure [Pa] Static Pressure [in. WG] HRV Static Pressure [Pa] Flow Rate, [CFM] Flow Rate, [CFM] HRV HRV 170 Dimensions Accessories Ø 6" 19 11/16 " 19 3/4 " Air disk valve 9 3/4 " 25 9/16 " Backdraft Dampers Clamps VENTS. Air handling units

10 Brig HRV 200, 300 A Heat Recovery Ventilator is a complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of stale air. Features Multizonal efficient recovery ventilation Cross flow core with recuperation efficiency up to 80% Silent operation Replaceable filters Simple installation and maintenance Compatible with 6 and 8 air ducts Electronic defrost protection Casing Steel casing is covered with high-quality multilayer aluminium and zinc alloy to prevent corrosion. The casing is equipped with a switch to turn the ventilator off when the service panel is opened. Filter Washable G4 air filters in exhaust and supply air streams. Optional supply: anti grease aluminum filter. Heat recovery core Specially designed polymer plate core ensure the top heat recovery efficiency. Whenever heat recovery is not required for unit operation the heat exchanger block can be easily replaced by a summer block. The unit is also equipped with the drain pan for condensate. Defrost system To protect the heat recovery core, the freezing electronic protection system is applied. It switches the supply fan off as the temperature sensor requires. Warm extract air defrosts the heat recovery core, then the supply fan switches on and the ventilator continues operating under rated conditions. Motors German made high-efficient motor combined with backward inclined impeller delivers exceptionally powerful airflow and high static pressure. Built-in thermal overheating protection with automatic restart makes the motor operation secure and reliable. Permanently lubricated ball bearings inside the motor provide long (40000 hours) trouble- and maintenance-free operation. Fans The ventilator is equipped with supply and exhaust centrifugal fans with backward inclined blades and built-in thermal overheating protection with automatic restart. The electric motors and the impellers are dynamically balanced in two planes. Control The ventilator is equipped with 3-step switch on it's side panel to choose STANDBY, LOW or MEDIUM mode for continuous operation. The unit can be equipped with wide range of additional controls (page 24) to switch boost on demand. Mounting The unit can be mounted in most positions and in most spaces. Please refer to installation manual for instructions and details. Warranty 5 year warranty Extract air Intake air Intake air Extract air Supply air Exhaust air Exhaust air Supply air HRV 200 HRV VENTS. Air handling units

11 VentsUS.com Performance HRV 200 HRV 300 Volts 120V, 60Hz 120V, 60Hz Max. Max. Amps RPM 0,1" (25Pa) (110) (184) 0,2" (Pa) 226 (107) 380 (179) 0,3" (75Pa) 218 (103) 365 (172) 0,4" (100Pa) 203 (96) 340 (160) 0,5" (125Pa) 191 (90) 315 (149) 0,6" (1Pa) 178 (84) 287 (135) Airflow CFM (L/s) 0,7" (175Pa) 164 (77) 258 (122) 0,8" (200Pa) 152 (72) 233 (110) 0,9" (225Pa) 138 (65) 208 (98) 1,0" (2Pa) 123 (58) 184 (87) 1,2" (300Pa) 86 (41) 137 (65) 1,4" (3Pa) 42 (20) 97 (46) 1,6" (400Pa) 1,8" (4Pa) Heat recovery core efficiency, % Duct Dia. - - < 80% 6'' 55 (26) 22 (10) < 80% 8'' Sensible efficiency(%) at 79 cfm 113 cfm 226 cfm 169 cfm HRV Sensible efficiency(%) at 133 cfm 190 cfm 380 cfm 285 cfm HRV Flow Rate, [L/s] Flow Rate, [L/s] Static Pressure [in. WG] HRV Static Pressure [Pa] Static Pressure [in. WG] HRV Static Pressure [Pa] Flow Rate, [CFM] Flow Rate, [CFM] HRV HRV 300 Dimensions Accessories Ø 6" 177 3/16 15/16 " Ø 8" 17 5/16 " 23 11/16 5/8 " 25 11/16 " 11 3/4 " 12 3/4 " Air disk valve 28 7/16 3/8 " 36 3/4 " HRV 200 HRV 300 Backdraft Dampers Clamps VENTS. Air handling units

12 Frigate HRV 60S, ERV 60S Both Heat and Energy Recovery Ventilators are the complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of stale air. Features Effective energy-saving solution Efficient recovery ventilation Cross flow core with recuperation efficiency up to 80% Heat recovery (HRV) or Energy Recovery (ERV) Silent operation Replaceable filters Ceiling installation Simple installation and maintenance Compact size Casing Steel casing is covered with high-quality multilayer aluminium and zinc alloy to prevent corrosion. The casing is equipped with a switch to turn the ventilator off when the service panel is opened. Filter Washable G4 air filters in exhaust and supply air streams. Optional supply: anti grease aluminum filter. Heat recovery core The aluminum cross-flow core (HRV 60s) ensures efficient heat recovery and the enthalpic core (ERV 60s) provides both heat&energy recovery. Defrost system To protect the heat recovery core, the freezing electronic protection system is applied. It switches the supply fan off as the temperature sensor requires. Warm extract air defrosts the heat recovery core, then the supply fan switches on and the ventilator continues operating under rated conditions. Motor German made high-efficient motor combined with backward inclined impeller delivers exceptionally powerful airflow and high static pressure. Built-in thermal overheating protection with automatic restart makes the motor operation secure and reliable. Permanently lubricated ball bearings inside the motor provide long (40000 hours) trouble- and maintenance-free operation. Fans The ventilator is equipped with supply and exhaust centrifugal fans with forward inclined blades and built-in thermal overheating protection with automatic restart. The electric motors and the impellers are dynamically balanced in two planes. Control The ventilator is supplied with a thyristor speed control. The unit can be equipped with wide range of additional controls (page 24) to switch boost on demand. Mounting The unit is mounted suspended to the ceiling with special belts. Please refer to installation manual for instructions and details. Warranty 5 year warranty Intake air Exhaust air Extract air Supply air 12 VENTS. Air handling units

13 VentsUS.com Performance HRV 60S ERV 60S Volts Max. Max. Amps 120V, 60Hz RPM 0,1" (25Pa) 63 (30) 0,2" (Pa) 56 (26) Airflow CFM (L/s) 0,3" (75Pa) (24) 0,4" (100Pa) 38 (18) 0,5" (125Pa) 24 (11) 0,6" (1Pa) 9 (4) Heat recovery core efficiency, % Duct Dia. < 80% 5 Sensible efficiency(%) at 28 cfm 39 cfm 56 cfm 47 cfm HRV 60S Sensible efficiency(%) at 28 cfm 39 cfm 56 cfm 47 cfm ERV 60S Flow Rate, [L/s] Static Pressure [in. WG] HRV 60S ERV 60S Static Pressure [Pa] Flow Rate, [CFM] HRV 60S ERV 60S Dimensions Accessories Ø 5" 14 3/4 " 8 7/16 " Air disk valve 6 7/16 " 19 1/2 " Backdraft Dampers Clamps VENTS. Air handling units

14 Frigate HRV 120S, ERV 120S Heat and Energy Recovery Ventilators are the complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of stale air. Features Effective energy-saving solution Multizonal efficient recovery ventilation Cross flow core with recuperation efficiency up to 80% Heat recovery (HRV) or Energy Recovery (ERV) Silent operation Replaceable filters Ceiling installation Simple installation and maintenance Casing Steel casing is covered with high-quality multilayer aluminium and zinc alloy to prevent corrosion. The casing is equipped with a switch to turn the ventilator off when the service panel is opened. Filter Washable G4 air filters in exhaust and supply air streams. Optional supply: anti grease aluminum filter. Heat recovery core Aluminum cross-flow core (HRV 120s) ensures efficient heat recovery and enthalpic core (ERV 120s) provides both heat&energy recovery. Defrost system To protect the heat recovery core, the freezing electronic protection system is applied. It switches the supply fan off as the temperature sensor requires. Warm extract air defrosts the heat recovery core, then the supply fan switches on and the ventilator continues operating under rated conditions. Motors German made high-efficient motor combined with backward inclined impeller delivers exceptionally powerful airflow and high static pressure. Built-in thermal overheating protection with automatic restart makes the motor operation secure and reliable. Permanently lubricated ball bearings inside the motor provide long (40000 hours) trouble- and maintenance-free operation. Fans The unit is equipped with supply and exhaust centrifugal fans with backward curved blades and build-in thermal overheating protection with automatic restart. The electric motors and the impellers are dynamically balanced in two planes. Control The ventilator is designed for permanent low speed operation. High speed can be turned on and off with the external switch. Both low and high speed are adjustable. The ventilator's speed is controlled with a 3-step speed switch located on the ventilator's side panel: LOW mode - minimum speed, MED mode - medium speed. In STANDBY mode the ventilator is controlled from the remote controller SAS 908 (optional supply). Mounting The unit is mounted suspended to the ceiling with special belts. Please refer to installation manual for instructions and details. Warranty 5 year warranty Intake air Exhaust air Extract air Supply air 14 VENTS. Air handling units

15 VentsUS.com Performance HRV 120S ERV 120S Volts 120V, 60Hz Max. Max. Amps RPM ,1" (25Pa) 1 (71) 0,2" (Pa) 143 (67) 0,3" (75Pa) 137 (65) 0,4" (100Pa) 127 (60) Airflow CFM (L/s) 0,5" (125Pa) 116 (55) 0,6" (1Pa) 104 (49) 0,7" (175Pa) 91 (43) 0,8" (200Pa) 78 (37) 0,9" (225Pa) 64 (30) 1,0" (2Pa) 49 (23) 1,2" (300Pa) 18 (8) Heat recovery core efficiency, % Duct Dia. < 80% 5'' Sensible efficiency(%) at cfm 71 cfm 143 cfm 107 cfm HRV 120S Sensible efficiency(%) at cfm 71 cfm 143 cfm 107 cfm ERV 120S Flow Rate, [L/s] Static Pressure [in. WG] HRV 120S ERV 120S high Static Pressure [Pa] 0.2 low Flow Rate, [CFM] low high HRV 120S ERV 120S Dimensions Accessories Ø 5" 20" 8 1/4 Air disk valve 9 15/16 " 21" Backdraft Dampers Clamps VENTS. Air handling units

16 Frigate HRV 100DS, ERV 100DS, TRV 100DS, HRV 1DS, ERV 1DS, TRV 1DS All Heat, Energy and Total Recovery Ventilators are the complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of stale air. Features Effective energy-saving solution Multizonal efficient recovery ventilation Enhanced output capacity Double cross flow cores with recuperation efficiency up to 90% Increased Heat (HRV) and (ERV) Energy Recovery Advantages of HRV and ERV in one unit Silent operation Replaceable filters Ceiling installation Casing Steel casing is covered with high-quality multilayer aluminium and zinc alloy to prevent corrosion. The casing is equipped with switch to turn the ventilator off when the service panel is opened. Filter Washable G4 air filters in exhaust and supply air streams. Optional supply: anti grease aluminum filter. Heat recovery core Two aluminum cross-flow cores (HRV 100Ds and HRV 1Ds) ensure the most efficient heat recovery. Two enthalpic cores (ERV 100Ds and ERV 1Ds) provide both heat&energy recovery. Unique combination of aluminum and enthalpic cores attains the best heat&energy recovery efficiency. Defrost system To protect the heat recovery core, the freezing electronic protection system is applied. It switches the supply fan off as the temperature sensor requires. Warm extract air defrosts the heat recovery core, then the supply fan switches on and the ventilator continues operating under rated conditions. Motor German made high-efficient motor combined with backward inclined impeller delivers exceptionally powerful airflow and high static pressure. Built-in Thermal Overheating Protection with Automatic Restart makes the motor operation secure and reliable. Permanently lubricated ball bearings inside the motor provide long (40000 hours) trouble- and maintenance-free operation. Fans The ventilator is equipped with supply and exhaust centrifugal fans with backward inclined blades and built-in thermal overheating protection with automatic restart. The electric motors and the impellers are dynamically balanced in two planes. Control The ventilator is designed for permanent low speed operation. High speed can be turned on and off with the external switch. Both low and high speed are adjustable. The ventilator's speed is controlled with a 3-step speed switch located on the ventilator's side panel: LOW mode - minimum speed, MED mode - medium speed. In STANDBY mode the ventilator is controlled from the remote controller SAS 908 (optional supply). Mounting The unit is mounted suspended to the ceiling with special belts. Please refer to installation manual for instructions and details. Warranty 5-year warranty Intake air Sensible efficiency(%) at 40 cfm 57 cfm 115 cfm 86 cfm Exhaust air HRV 100DS ERV 100DS TRV 100DS Sensible efficiency(%) at 52 cfm 74 cfm 148 cfm 111 cfm HRV 1DS ERV 1DS Supply air TRV 1DS Extract air 16 VENTS. Air handling units

17 VentsUS.com Performance HRV 100DS ERV 100DS TRV 100DS HRV 1DS ERV 1DS TRV 1DS Volts 120V, 60Hz 120V, 60Hz Max. Max. Amps RPM ,1" (25Pa) 120 (57) 1 (71) 0,2" (Pa) 115 (54) 148 (70) 0,3" (75Pa) 109 (51) 144 (68) 0,4" (100Pa) 98 (46) 136 (64) 0,5" (125Pa) 88 (42) 128 (60) Airflow CFM (L/s) 0,6" (1Pa) 77 (36) 120 (57) 0,7" (175Pa) 65 (31) 111 (52) 0,8" (200Pa) 52 (25) 101 (48) 0,9" (225Pa) 38 (18) 91 (43) 1,0" (2Pa) 24 (11) 79 (37) 1,2" (300Pa) 1,4" (3Pa) Heat recovery core efficiency, % Duct Dia. - - < 90% 5 53 (25) 23 (11) < 90% 5 Flow Rate, [L/s] Flow Rate, [L/s] Static Pressure [in. WG] HRV 100DS ERV 100DS TRV 100DS high Static Pressure [Pa] Static Pressure [in. WG] HRV 1DS ERV 1DS TRV 1DS high Static Pressure [Pa] 0.2 low low Flow Rate, [CFM] Flow Rate, [CFM] low high HRV 100DS ERV 100DS TRV 100DS low high HRV 1DS ERV 1DS TRV 1 DS Dimensions Accessories Ø 5" 20 3/8 " 8 1/4 " Air disk valve 12 11/16 " 30 3/16 " Backdraft Dampers Clamps VENTS. Air handling units

18 Single Room TOTAL Recovery Ventilators TwinFresh S-60, S-60-2 Benefits No need to pay for air ducts No need to pay for grilles No need to pay for installation of complicated ventilation duct system Extremely high ERV core efficiency up to 91% Features: The ventilator with a square air duct is specially designed for easy mounting in new construction. Efficient supply and exhaust single room ventilation High-tech polymer ceramic energy accumulator with regenerating efficiency up to 91% EC-motor Integrated automation with four operating patterns Silent operation ( Sones) Easy installation Air purification with two built-in G3 filters Rated for continuous operation The Single Room Total Recovery ventilator TwinFresh S is an easy and effective solution for rooms and smaller areas. Front grille (1) Modern design of the front grille makes it look great in any interior. Easy access for filter cleaning or replacement. The front grille is made of high quality snow-white ABS plastic. Air filtration (2) Two G3 built-in filters provide fresh air free of dust, pollen, insects. Motor (3) 1 2 The latest EC-motor technology ensures low energy costs.the motor has integrated overheating protection and ball bearings for longer service life. Polymer ceramic energy accumulator (regenerator) (4) The ventilator includes a high-tech polymer ceramic energy accumulator with regenerating efficiency up to 91% Control and operating modes The automation system has four operating patterns: 1. Ventilation mode (extract or supply mode) at low speed with air capacity 20.6 CFM; 2. Ventilation mode (extract or supply mode) at high speed with air capacity 34.1 CFM; 3. Reverse mode (regeneration) at low speed with air capacity 20.6 CFM; 4. Reverse mode (regeneration) at high speed with air capacity 34.1 CFM The required operation mode is selected using the control panel supplied with the model TwinFresh SA. The control panel for the model TwinFresh S is available upon separate order. Exterior Protection (5) The exterior is constructed of aluminum covered with a special polymer coating to ensure long-lasting protection from the elements. A grill protects water and foreign objects from entering the unit. Supply/ extract mode Reverse mode On High speed Low speed Off Supplied with TwinFresh SA only 18 VENTS. Air handling units

19 VentsUS.com How the TwinFresh S Works CYCLE I. Warm stale air is extracted from the room passing through the ceramic accumulator, which captures up to 91% of the thermal energy of the air being extracted. As the accumulator gets heated, the ventilator switches to air supply mode. CYCLE II. As the fresh outside air passes the opposite way through the accumula- 14 o F 68 o F 68 o F 70 sec. AIR EXTRACT CYCLE I 68 o F tor, it absorbs the heat and moisture which was extracted from the room air that was exhausted. As the temperature of the accumulator decreases, the fan switches back to extraction mode and the cycle starts all over again. The ventilator changes its operation mode for supply or extract ventilation every 70 seconds. This time 14 o F interval can be adjusted during installation from 30 to 120 seconds. 14 o F AIR SUPPLY 70 sec. 68 o F CYCLE II Technical data 14 o F TwinFresh S Speed Voltage [V] Power [W] Air capacity [CFM] Rotation speed [min -1 ] Sones 1 2, /60 Hz 2 3, Ingress protection rating IP 45 *In reverse mode the stated air capacity is shared for both directions Overall dimensions [inch] Accessories TwinFresh S-60 10" 6 7/16" Replaceable front grilles 10 1/16" 18 11/16" 11 5/8" RV TwinFresh S alumat Grey metallic RV TwinFresh S alu Natural brushed aluminium 2 13/16" RV TwinFresh S gold Natural gold painted aluminium RV TwinFresh S chrome Natural mirror aluminium 10 13/16" TwinFresh S /8" 6 7/16" 4 3/4" - 13" 12 3/8" 8 11/16" 10 13/16" Control panel KVS Power transformer TRF 110/12-6 (6 W) TRF 110/12-12 (12 W) VENTS. Air handling units

20 TwinFresh R-, R--2 Benefits No need to pay for air ducts No need to pay for grilles No need to pay for installation of complicated ventilation duct system Extremely high ERV core efficiency up to 91% Features: The ventilator with a round duct is specially designed for easy mounting in refurbished and reconstructed ready-built buildings. Efficient supply and exhaust single room ventilation High-tech ceramic energy accumulator with regenerating efficiency up to 91% EC-motor Integrated automation with four operating patterns Silent operation ( Sones) Easy installation Air purification with two built-in G3 filters Rated for continuous operation 1 2 The Single Room Total Recovery ventilator TwinFresh R is an easy and effective solution for rooms and smaller areas. Front grille (1) Modern design of the front grille makes it look great in any interior. The grille is fitted with a thermal actuator and automatic louvre shutters that are opened during operation of the ventilator and are closed during standby. The front grille is made of high quality snow-white ABS plastic. Air filtration (2) Two G3 built-in filters provide fresh air free of dust, pollen, insects. Motor (3) 4 The latest EC-motor technology ensures low energy costs. The motor has integrated overheating protection and ball bearings for longer service life. Polymer ceramic energy accumulator (regenerator) (4) 3 5 The ventilator includes a high-tech polymer ceramic energy accumulator with regenerating efficiency up to 91%. Control and operating modes The automation system has four operating patterns: 1. Ventilation mode (extract or supply mode) at low speed with air capacity 14.7 CFM; 2. Ventilation mode (extract or supply mode) at high speed with air capacity 29.4 CFM; 3. Reverse mode (regeneration) at low speed with air capacity 14.7 CFM; 4. Reverse mode (regeneration) at high speed with air capacity 29.4 CFM The required operation mode is selected using the control panel supplied with the model TwinFresh RA. The control panel for the model TwinFresh R is available upon separate order. Exterior Protection (5) Supply/ extract mode Reverse mode High speed Low speed The exterior is constructed of aluminum covered with a special polymer coating to ensure long-lasting protection from the elements. A grill protects water and foreign objects from entering the unit. Supplied with TwinFresh RA only On Off 20 VENTS. Air handling units

21 VentsUS.com How the TwinFresh R Works 68 o F 70 AIR EXTRACT CYCLE I CYCLE I. Warm stale air is extracted from the room passing through the ceramic accumulator, which captures up to 91% of the thermal energy of the air being ex- 14 o F sec. tracted. As the accumulator gets heated, the ventilator switches to air supply mode. CYCLE II. As the fresh outside air passes the opposite way through the accumula- 68 o F 68 o F tor, it absorbs the heat and moisture which was extracted from the room air that was exhausted. As the temperature of the accumulator decreases, the fan switches back to extraction mode and the cycle starts all over again. The ventilator changes 14 o F its operation mode for supply or extract ventilation every 70 seconds. This time interval can be adjusted during installation from 30 to 120 seconds. 14 o F AIR SUPPLY 70 sec. 68 o F CYCLE II Technical data 14 o F TwinFresh R Speed Voltage [V] Power [W] Air capacity [CFM] Rotation speed [min -1 ] Sones 1 1, /60 Hz 2 3, Ingress protection rating IP 45 *In reverse mode the stated air capacity is shared for both directions Overall dimensions [inch] Accessories 10" 6 1/8" TwinFresh R- 9 13/16" /2" 101 3/16" Rectangular plastic grille MV 125 VDs Angle mounting kit NP 60х /16" 8 3/8" TwinFresh R /8" 9 5/8" Round plastic grille MV 1 bvs Stainless steel outer hood MV 152 bvs N 4 3/4" /8" 9 3/4" 8 7/16" 8 3/8" Control panel KVR Power transformer TRF 110/12-6 (6 W) TRF 110/12-12 (12 W) VENTS. Air handling units

22 Single room HRV MICRA 60 Micra 60 is the single room heat recovery ventilator for larger rooms and areas, including apartments and small commercial spaces. No need to connect air ducts. A great solution for simple and efficient ventilation in retrofits. Features Efficient heat recovery ventilation for separate rooms Up to 90% energy recovery efficiency. EC-motor Three operating modes Silent operation ( Sones) Air cleaning with two G4 built-in filters Easy mounting Suitable for continuous operation 2 1 Casing (1) Polymer coated metal casing decorated with mirror stainless steel and internally filled with 9/16" thermal and sound insulating layer. Modern unit design makes it match well with any interior. The removable front panel provides easy access for filter cleaning or replacement. Air is supplied to the room and exhausted outside through two 5" air ducts. Air filtration (2) Two G4 built-in filters provide cleaning of supply and extract air. The filters serve to ensure supply of fresh air free of dust, pollen and insects and protect the unit from soiling. 3 Motor (3) Axial fans are powered by energy-efficient EC-motors. The motors are equipped with built-in thermal overheating protection and ball bearings for longer service life. Heat recovery core (4) The ventilator is equipped with a high-tech plate counter-flow aluminium heat recovery core reaching up to a 78% recovery efficiency. Using the MICRA in both cooling and heating seasons results in considerable energy savings. 4 5 Freeze protection The MICRA includes special thermostats that prevent any condensate from freezing. Control unit (5) The unit is powered through an integrated pulser unit with a wide range of supply voltage from 100 V to 240 V and frequency from to 60 Hz. The power unit has integrated protection for various emergencies including short circuit, overload, voltage jumps, reverse polarity in output circuits. Control and operation modes Automatic system enables three operation modes: 1. Supply and exhaust ventilation at minimum air capacity 17.7 CFM and minimum noise level 0.38 Sones. 2. Supply and exhaust ventilation at medium air capacity 26.5 CFM and minimum noise level 0.42 Sones. 3. Supply and exhaust ventilation at medium air capacity 35.3 CFM and minimum noise level 1.0 Sones. 22 VENTS. Air handling units

23 VentsUS.com How it Works Fresh air from outside moves through the filter and core. Warm stale air from the room moves through the filter and core and then is exhausted outside. The thermal energy of the extracted warm inside air is transferred to the fresh outside air that is being drawn in. The intake and extract air flows are fully separated. Supply filter Extract filter Supply air Heat recovery core Extract air Technical data Speed Voltage Micra 60 Power [W] Current [A] Air capacity [CFM] Rotation speed [min -1 ] Sones 1 4,2 0,02 17, V -60 Hz 9,6 0,04 26, ,4 0,07 35, Ingress protection rating IP 22 Overall dimensions [inch] Accessories dimensions [inch] 7 3/8" 7 5/16" 14" 15 1/4" 4 3/4" 15 1/2" 2 5/16" О 4 7/8" Mounting set MK MICRA 60: two air ducts PVC19 11/16 long; one outer metal twin hood. 5 1/8" 20 3/8" 20 11/16" 5 1/8" Mounting metal master plate MP MICRA 60. Used to fix air ducts in required position and to align the unit branch pipes and air ducts precisely. The master plate is installed during general construction stage. VENTS. Air handling units

24 Optional remote controls TRANSMITTER CO 2 Thermostat SAS908PIT The modulating digital thermostat is designed to select one of three fan speeds. As the thermostat is off the unit is switched to STANDBY mode. The product also provides proportional-integral temperature regulation of fancoil dampers, equipment for zonal heating in commercial applications and transfers air conditioning control signals. CO 2 transmitter For offices or other public places. Provides high speed ventilation when CO 2 level exceeds selected setting. Ventilator Important Base module Low Voltage is 24 Volt AC. Do not connect external power sources to the ventilator! 2 Wire conrtol Devices (Low Woltage) OFF ON 20% 30% 40% % 30 OFF OFF MAX CRANK TIMER TOGGLE SWITCH HUMIDITY CONTROL Crank Timer Location: bathroom or kitchen area to bring on high speed ventilation as required Crank Timer 60 min Toggle switch Important Base module Low Voltage is 24 Volt AC. Do not connect external power sources to the ventilator! Remote dehumidistat Location: kitchen and bathroom, SPA or swimming pool (anywhere humidity is a concern). Provides high speed ventilaion when humidity level selected setting. SPEED CONTROL Speed control LOW STANDBY MED Each unit is equipped with one three-key speed switch to select low speed or medium speed. In STANDBY mode the unit is waiting to response to external signal. All double-wire devices switch the units to maximum speed irrespective of the switch position. 24 VENTS. Air handling units

25 20% 10 % OFF 30% MAX OFF 30 CRANK TIMER 20 ON OFF VentsUS.com Electrical accessories compatibility Thermostat SAS908PIT Remote dehumidistat CO 2 transmitter Crank Timer Toggle switch Speed control RS Four position switch Control unit 40% CO 2 TRANSMITTER 10 HUMIDITY CONTROL TOGGLE SWITCH Vents VUT 200 mini Vents Brig HRV 120 Vents Brig HRV 170 Vents Brig HRV 200 Vents Brig HRV 300 Vents Frigate HRV 60S Vents Frigate ERV 60S Vents Frigate HRV 120S Vents Frigate ERV 120S Vents Frigate HRV 100 DS Vents Frigate ERV 100 DS Vents Frigate TRV 100 DS Vents Frigate HRV 1 DS Vents Frigate ERV 1 DS Vents Frigate TRV 1 DS TwinFresh R TwinFresh S Micra 60 VENTS. Air handling units

26 Quick Selection Table Heat Recovery Ventilators (HRV) Area of house Sq. Ft Up To 1200 Up To 2000 Up To 2400 Up To 3000 Up To 3400 Up To 4000 Up To 6000 HRV 60S HRV 100DS VUT 200 mini HRV 120S HRV 120 HRV 1DS HRV 170 HRV 200 HRV 300 (HRV) Duct Dia. 5'' 5'' 4'' 5'' 6'' 5'' 6'' 6'' 8'' Max Airflow CFM (L/s) 56 (26) 115 (54) (67) 160 (76) 148 (70) 178 (84) 226 (107) 380 (179) Efficiency of heat exchanger, % < 80% < 90% < 80% < 80% < 80% < 90% < 80% < 80% < 80% Energy Recovery Ventilators (ERV)/Total Recovery Ventilators (TRV) Area of house Sq. Ft Up To 1200 Up To 2000 Up To 2400 Up To 3000 ERV 60S ERV 100DS HRV 120S ERV 1DS (ERV) TRV 100DS TRV 1DS (TRV) Duct Dia. 5'' 5'' 5'' 5'' Max Airflow CFM (L/s) 56 (26) 115 (54) 143 (67) 148 (70) Efficiency of heat exchanger, % < 80% < 90% < 80% < 90% Certification 26 VENTS. Air handling units

27 Tel: Tel: Fax: VentsUS.com Kenwood Road Cincinnati, Ohio /2014

COMMERCIAL VENTILATION

COMMERCIAL VENTILATION COMMERCIAL VENTILATION www.canarm.com hvacsales@canarm.ca HVAC CONTACTS CORPORATE OFFICE / HVAC MANUFACTURING FACILITY 2157 Parkedale Avenue, PO Box 367 Brockville, ON K6V 5V6 Canada Tel: (613) 342-5424

More information

WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

WORLD VENTILATION LEADER   SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS WORLD VENTILATION LEADER IO EM.COM SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS VENTS reserves the rights to modify any of its products featuers, designs, components and specifications

More information

SINGLE-ROOM ENERGY RECOVERY VENTILATORS

SINGLE-ROOM ENERGY RECOVERY VENTILATORS SINGLE-ROOM ENERGY RECOVERY VENTILATORS Silent operation Easy mounting Multi-purpose functioning TWINFRESH COMFO RB1-50 SINGLE-ROOM VENTILATORS EFFICIENT, RELIABLE AND ENERGY-SAVING VENTILATORS TWINFRESH

More information

SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS

SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS SINGLE-ROOM HEAT RECOVERY UNITS FRESHBOX 60 Use q Heat recovery single-room air handling unit for supply and exhaust ventilation. q Efficient energy-saving single-room

More information

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S USER S MANUAL Heat (Energy) Recovery Ventilator Vents Frigate HRV 120 S Vents Frigate ERV 120 S 2 Frigate HRV(ERV) 120 S CONTENT Introduction... 3 Application... 3 Delivery set... 3 Unit designation key...

More information

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 % Single-room heat recovery unit Air flow up to 59 CFM Heat recovery efficiency up to 96 % 2018 SINGLE-ROOM HEAT RECOVERY UNITS Features Efficient solution for supply and exhaust ventilation of enclosed

More information

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS ENERGY-SAVING VENTILATION SOLUTIONS TO IMPROVE INDOOR AIR QUALITY Quality Features Built Into Every Model Compact

More information

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1) c a i r c im M Si l g n e r m o o ai a h r r ving i a a ze h s gy s t si e Fr e r p a c En m Co a r th i y w r t s ov e i un rec g t n li ea d n h in t e til oun a rs m ise e V sy no Ea w Lo g Industrial

More information

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit USER MANUAL Frigate HRV 120 SR Frigate ERV 120 SR Heat (energy) recovery ventilation unit 2 CONTENTS Safety requirements... 3 Introduction... 5 Use... 5 Included in the box... 5 Designation key... 5 Technical

More information

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 % FRESHBOX 100 Single-room heat recovery unit Air capacity up to 100 m³/h Heat recovery efficiency up to 96 % FRESHBOX 100 CONTENTS FRESHBOX 100 FEATURES 3 DESIGN 4 OPERATING PRINCIPLE 6 CONTROL 6 APPLICATION

More information

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units. AIR HANDLING UNITS WITH HEAT RECOVERY Series VUT PE EC Series SAS908 control panel SAS908 control panel Ceiling mounted energy saving Air Handling Units (AHU) with the air capacity up to 4000 m 3 /h and

More information

KOMFORT EC DB Suspended heat recovery air handling units

KOMFORT EC DB Suspended heat recovery air handling units 2018 AIR HANDLING UNITS KOMFORT EC DB Suspended heat recovery air handling units Features Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings.

More information

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code CONTENTS Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code 2 4 6 8 10 12 14 16 18 19 20 KITCHEN AND BATHROOM FANS The Vitro &

More information

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300 USER S MANUAL Heat Recovery Ventilator Vents Brig HRV 200 Vents Brig HRV 300 2 Brig HRV 200 (300) CONTENT Introduction... 3 Application... 3 Delivery set... 3 Unit designation key... 4 Basic unit dimensions...

More information

Residential Heat & Energy Recovery

Residential Heat & Energy Recovery Residential Heat & Energy Recovery Aeromatic Series Standard Residential HRV/ERV 95-215 CFM 2 Discover Heat & Energy Recovery A tightly built, high-performance home is a great way to conserve energy and

More information

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S Heat and Energy Recovery Ventilators 2018 AIR HANDLING UNITS 2 CONTENT KOMFORT EC S5B270(-E) 4 KOMFORT EC D5B1(-E) 8 KOMFORT EC S(B)(-E) 12 AIR HANDLING UNITS

More information

Caution: The fans must not be used in bath or shower enclosures.

Caution: The fans must not be used in bath or shower enclosures. The Vitro & Vitro Star represent VENTS s newest innovation of axial extract residential fans. With glass decorative cover the fans are beautiful enrichment to the interiors, an ideal combination of form

More information

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits RESIDENTIAL SYSTEM SOLUTIONS VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits VentZone Zoned IAQ Kits with Energy Recovery combine a Standard Residential Energy Recovery Ventilator (ERV) with

More information

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits RESIDENTIAL SYSTEM SOLUTIONS VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits VentZone Zoned IAQ Kits with Heat Recovery combine a Standard Residential Heat Recovery Ventilator (HRV) with residential

More information

Destratification Fan Units DRF-VK & DRF-VKM & DRF-OV

Destratification Fan Units DRF-VK & DRF-VKM & DRF-OV Destratification Fan Units DRF-VK & DRF-VKM & DRF-OV Thermal Stratification Number One Reason for Energy Waste in Todays Buildings Tel: 1-888-640-0925 Tel: 513-348-3853 Fax: 513-268-4597 sales@ventsus.com

More information

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS enthalpy membrane in the warm season. This allows for a considerable reduction of the supply air temperature and humidity which, in turn, reduces the

More information

Limited Lifetime core warranty. 5-year warranty on balance of unit.

Limited Lifetime core warranty. 5-year warranty on balance of unit. MODEL FEATURES Polypropylene HRV core 3 operating modes Painted galvanized steel case Designed for simple installation by a single person Fully insulated case Limited lifetime warranty on the heat recovery

More information

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV Inspir Compact Heat and Energy Recovery Multi-Family HRV/ERV High-Profile Performance & Low-Profile Design Small spaces demand smart technology. Aldes Inspir Compact Heat and Energy Recovery Ventilators

More information

Description of components and operating logic of the unit MICRA Ventilation system arrangement example based on the unit MICRA 60...

Description of components and operating logic of the unit MICRA Ventilation system arrangement example based on the unit MICRA 60... CONTENT About VENTS...2 Ventilation in our life...4 MICRA air handling units - comfortable climate in your house...6 MICRA 60 Description of components and operating logic of the unit MICRA 60...8 Ventilation

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Energy Recovery Ventilator (ERV) STANDARD 5 YEAR PARTS LIMITED WARRANTY When installed and registered with a complete Maytag system, this product carries a 12 Year All Parts Warranty.

More information

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater SUPPLY UNITS Series Series LCD control panel SAS908 control panel Supply units with the air capacity up to 3500 m 3 /h in the compact sound- and heat-insulated casing with electric heater Supply units

More information

5 year fan housing and motor warranty

5 year fan housing and motor warranty MODEL SWF SIDEWALL CENTRIFUGAL FAN MODEL FEATURES Exhaust air up to 416 CFM with static pressure capabilities to 1.5 w.g. Galvanized steel casing with black backed enamel coating Pre-wired junction box

More information

Series VENTS VUT R WH ЕС

Series VENTS VUT R WH ЕС AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS EH ЕС Series VENTS WH ЕС Air handling units with the air capacity up to 1500 m 3 /h in soundand heat-insulated casing with integrated electric heater.

More information

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators Residential and Commercial HRVs & ERVs Heat Recovery Ventilators & Energy Recovery Ventilators Residential HRVs - Horizontal Recirculating Defrost SUPERVENTOR SERIES Color coded collars easily identify

More information

Put the V back in HVAC

Put the V back in HVAC Put the V back in HVAC V is for Ventilation A system or means of providing fresh air. Webster New Collegiate Dictionary Benjamin Franklin so unwholesome as air in a closed room that has been often breathed

More information

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models. AIR HANDLING UNITS WITH HEAT RECOVERY Series Series VUT 350 PE EC VUT 600 PE EC VUT 1000 PE EC VUT 2000 PE EC VUT 3000 PE EC VUT 600 PW EC VUT 1000 PW EC VUT 2000 PW EC VUT 3000 PW EC Ceiling mounted air

More information

Outside Air Requirements... SOLVED!

Outside Air Requirements... SOLVED! Outside Air Requirements... SOLVED! Advancing VentilationTM refresh-0918 September 2018 The Whole Building Ventilation Standard With houses and buildings being built as tightly as possible, we are plagued

More information

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models. AIR HANDLING UNITS WITH HEAT RECOVERY Series Series VUT 350 PE EC VUT 600 PE EC VUT 1000 PE EC VUT 2000 PE EC VUT 3000 PE EC VUT 600 PW EC VUT 1000 PW EC VUT 2000 PW EC VUT 3000 PW EC Ceiling mounted air

More information

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators Residential and Commercial HRVs & ERVs Heat Recovery Ventilators & Energy Recovery Ventilators Residential HRVs - Horizontal Recirculating Defrost SUPERVENTOR SERIES Color coded collars easily identify

More information

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV) Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics RNC Series Models RNC95 RNC155 RNC200 RNC10 RNC20 RNC120D RNC5-TPD Residential Heat Recovery Ventilators (HRV) Manufactured

More information

HEAT RECOVERY VENTILATOR

HEAT RECOVERY VENTILATOR HEAT RECOVERY VENTILATOR HRV H 00 ERV H 00 HRV H 300 ERV H 300 EN OPERATION MANUAL HRV /ERV H 00(300) www.blaubergventilatoren.de CONTENTS Application... Delivery set...3 Unit designation key...3 Basic

More information

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY Product Overview www.orcaenergy.eu MAXI Device for heat recovery MAXI is designed to provide permanent controlled air exchange by means of mechanical ventilation

More information

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty MODEL OVERVIEW The POWERVENT (PV) series of direct drive centrifugal in-line duct ventilation fans consists of twelve model sizes 4, 5, 6, 8, 10 and 12.4 respectively. All models are designed for direct

More information

Domestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5.

Domestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5. Domestic fans Circular duct fans Rectangular duct fans Roof fans xial fans Smoke evacuation fans TEX rated fans Corrosion resistant fans Domestic fans ccessories Wiring diagrams 0 Index Content Centrifugal

More information

Ventilation Solutions IAQ Canada

Ventilation Solutions IAQ Canada Ventilation Solutions IAQ Canada 2 Ventilation Solutions IAQ Ventilation Solutions IAQ 3 Indoor Air Quality Keep your family safe Safeguard Your Home Three easy steps Your home should be safe and comforting,

More information

ENERGY SAVING VENTILATION GEO VENTS GEOTHERMAL SYSTEMS

ENERGY SAVING VENTILATION GEO VENTS GEOTHERMAL SYSTEMS ENERGY SAVING VENTILATION GEO VENTS GEOTHERMAL SYSTEMS 2010 Contents Geothermal Ventilation systems Geothermal heat exchanger - economy and comfort 2 Ventilation efficiency with ground heat exchanger and

More information

DES CHAMPS PRODUCTS 85% 4,400 CFM

DES CHAMPS PRODUCTS 85% 4,400 CFM DES CHAMPS PRODUCTS Saves up to 85% of the heat from exhaust airstream Removes pollutants before they accumulate Transfers heat energy in winter/cool energy in summer Low cost Capacities up to 4,400 CFM

More information

Tuning up ventilation systems

Tuning up ventilation systems MULTI-UNIT RESIDENTIAL BUILDINGS Tune-Ups for Energy and Water Efficiency This document is a tool to help reduce energy and water costs and improve comfort in a high-rise residential building through low-cost

More information

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220 INSTALLATION GUIDE Horizontal series HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220 INSTALLATION GUIDE Peace of Mind All GeneralAire products are backed by the best limited warranty in the

More information

VERTICAL FAN COIL UNITS

VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS Model: CT & TCE 2 - Pipe 350 cfm to 1200 cfm capacity 4-row water coil 120v or 24v controls Electric heating coil (TCE Model) Fresh air connection from remote

More information

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will

More information

Light commercial models

Light commercial models Installation Manual Item #: 422468 Rev Date: 051414 Light commercial models Energy Recovery Ventilators SER 5504 SER 8504 SER 11504 Your ventilation system should be installed in conformance with the appropriate

More information

MODEL TRC TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS

MODEL TRC TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS MODEL FTURES MERV-8 filters Transformer/relay package allowing simple on/off control Access doors for easy access to blowers, core and filters

More information

Product Catalog Commercial Solutions US Edition

Product Catalog Commercial Solutions US Edition Product Catalog Commercial Solutions US Edition 2 Introduction Quality products, reliable service and leaders in innovation For more than 30 years, Fantech has been researching, designing and bringing

More information

Fans for Life! CA-TD0708. The World s Leading Producer of Air Movement Products

Fans for Life! CA-TD0708. The World s Leading Producer of Air Movement Products Fans s for f Life! CA-TD0708 The World s Leading Producer of Air Movement Products TD In-line Mixed Flow Duct Fans Soler & Palau (S&P) USA and Canada are the most recent additions to, and are wholly owned

More information

SINGLE-ROOM VENTILATION. for schools and public spaces

SINGLE-ROOM VENTILATION. for schools and public spaces SINGLE-ROOM VENTILATION for schools and public spaces Industrial and commercial ventilation (Catalogue no. 1) Industrial and commercial ventilation components - fans for round and rectangular ducts, sound-insulated,

More information

Product Catalog Commercial Solutions US Edition

Product Catalog Commercial Solutions US Edition Product Catalog Commercial Solutions US Edition 2 Introduction Quality products, reliable service and leaders in innovation For more than 30 years, Fantech has been researching, designing and bringing

More information

HEALTHY CLIMATE Heat / Energy Recovery Ventilator

HEALTHY CLIMATE Heat / Energy Recovery Ventilator PRODUCT SPECIFICATIONS INDOOR AIR QUALITY HRV / ERV HEALTHY CLIMATE Heat / Energy Recovery Ventilator Bulletin No. 210528 November 2017 Supersedes March 2017 HRV5-150 ERV3-150, -200 HRV3-150-TPD/TPF, HRV5-200-TPD

More information

HEAT RECOVERY VENTILATOR

HEAT RECOVERY VENTILATOR HEAT RECOVERY VENTILATOR CONSTRUCTO 1.0 HRV Part no. 41502 (TOP PORTS) Part no. 41500 (SIDE PORTS) 39 to 98 CFM (0.4 in. w.g.) VB0069 AN INGENIOUS AIR EXCHANGE SOLUTION THAT S AS VERSATILE AS IT IS COMPACT!

More information

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home. HRV / ERV Heat or Energy Recovery Ventilation Systems You need fresh air, so does your home. Control Your Indoor Air Quality Following the energy crisis of the 1970s, we tended to insulate our homes and

More information

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h FANS FOR ROUND DUCTS Series VENTS ТТ PRO Series VENTS ТТ perform required servicing. All the models may be equipped with a regulated timer with turn-off delay adjustable from 2 to 30 min. TT PRO design

More information

BROAN ERVS100 Part no. ERVS100S CFM (0.4 in. w.g.)

BROAN ERVS100 Part no. ERVS100S CFM (0.4 in. w.g.) BROAN ERVS100 Part no. ERVS100S 65-105 CFM (0.4 in. w.g.) Product balancing The ERVS100 is equipped with 2 high static pressure blowers and is factory balanced. At installation, the ERVS100 will remain

More information

Domestic & Commercial Fans

Domestic & Commercial Fans Max. airflow l/s Axial Fan Centrifugal Fan Speed Controllable Reversible Airflow Page Number BF IF CF CBF BF 64 * 16 IF 64 * 16 EAF LV 23 * 169 ECF LV 31 * 169 CF 25 * 170 CBF 31 * 170 RVF 0 * * 171 BRAVO

More information

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions) NUAIRE MVHR (including opposite handed versions) ACHIEVES 100% DUTY IN BYPASS MODE and MRXBOXAB- ECO-LP1-OH are specically designed for apartment applications where space is a premium. The new MRXBOX95-LP1

More information

IAQ VENTILATION SOLUTIONS

IAQ VENTILATION SOLUTIONS IAQ VENTILATION SOLUTIONS HEAT RECOVERY VENTILATORS ENERGY RECOVERY VENTILATORS WHOLE HOUSE HEPA FILTRATION I M P R O V I N G I N D O O R A I R Q U A L I T Y T H R O U G H B E T T E R V E N T I L A T I

More information

Heat Recovery Ventilators models:

Heat Recovery Ventilators models: User s Manual Read and save these instructions. Heat Recovery Ventilators models: 1000 HE 2000 HE 3000 HE 3055 Compact HE 1.3 HE 1.8 HE 2.6 5585 Compact VB0021 VVI, 550 Lemire Blvd., Drummondville, Qc,

More information

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

Inline mixed-flow fans with the air capacity up to 450 m 3 /h FANS FOR ROUND DUCTS Series VENTS ТТ PRO Series VENTS ТТ perform required servicing. All the models may be equipped with a regulated timer with turn-off delay adjustable from 2 to 30 min. TT PRO design

More information

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS With S&P s TR & TRC (total recovery) Series for all climates, stale room air is exhausted and fresh outdoor air is brought back into the house. These two air streams are directed through a highly developed

More information

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home. HRV / ERV Heat or Energy Recovery Ventilation Systems You need fresh air, so does your home. Control Your Indoor Air Quality Following the energy crisis of the 1970s, we tended to insulate our homes and

More information

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS. User Manual HEAT RECOVERY VENTILATORS MODELS: 1000 HE HE 1.3 2000 HE HE 1.8 3000 HE HE 2.6 3055 COMPACT 5585 COMPACT VB0021 READ AND SAVE THESE INSTRUCTIONS. VVI, 550 Lemire Blvd., Drummondville, QC, Canada

More information

SER Models. SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

SER Models. SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will operate if connected

More information

TR Series - The Ultimate ERV

TR Series - The Ultimate ERV TR Series The Ultimate ERV Total Recovery for All Climates Featuring Vent Lights and Premium Grilles Fans s for f Life! The World s Leading Producer of Air Movement Products TR_0810 Indoor Air Quality

More information

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier RXID-AW90A Whole House Dehumidifier with fresh air ventilation Installation Guide Dehumidification Fresh Air Ventilation Compact Size Energy Efficient The whole house dehumidifier integrates highcapacity

More information

SAFETY AND INSTALLATION MANUAL MODEL 8100

SAFETY AND INSTALLATION MANUAL MODEL 8100 SAFETY AND INSTALLATION MANUAL ENERGY RECOVERY VENTILATORS MODEL 8100 Provides year-round fresh air Recovers 77% of the apparent heating or cooling energy from the exhausted air See Warnings Page 3 Table

More information

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2 USER'S MANUAL TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2 TwinFresh S-60 TwinFresh SA-60 TwinFresh S-60-2 TwinFresh SA-60-2 TwinFresh S-50 TwinFresh SA-50 TwinFresh S-50-2 TwinFresh

More information

IAQ VENTILATION SOLUTIONS

IAQ VENTILATION SOLUTIONS IAQ VENTILATION SOLUTIONS HEAT RECOVERY VENTILATORS ENERGY RECOVERY VENTILATORS WHOLE HOUSE HEPA FILTRATION IMPROVING INDOOR AIR QUALITY THROUGH BETTER VENTILATION July 2006 IAQ0706 www.fantech.net What

More information

USER GUIDE MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY rev.

USER GUIDE MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY rev. USER GUIDE VB0100 MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS 07919 rev. B About this Guide This guide uses the following symbols

More information

50% 80% 7 Years. Filter. Ventilation Solutions IAQ Canada. Ventilate. of our time is spend indoors. Limited warranty on motors

50% 80% 7 Years. Filter. Ventilation Solutions IAQ Canada. Ventilate. of our time is spend indoors. Limited warranty on motors Ventilation Solutions IAQ Canada 50% of people surveyed were not aware the poor indoor air quality is one of the top 5 most urgent environmental risks to public health. Filter 80% of our time is spend

More information

Energy Recovery Ventilators

Energy Recovery Ventilators Energy Recovery Ventilators ERV-150 ERV-200 IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will operate

More information

Heat or Energy Recovery Ventilation System

Heat or Energy Recovery Ventilation System INSTALLATION MANUAL Heat or Energy Recovery Ventilation System MODELS: FC80 HRV & FC80 ERV This device MUST be installed by a qualified agency in accordance with the manufacturer's installation instructions.

More information

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS With S&P s TR & TRC (total recovery) Series for all climates, stale room air is exhausted and fresh outdoor air is brought back into the house. These two air streams are directed through a highly developed

More information

ENERGY RECOVERY VENTILATOR

ENERGY RECOVERY VENTILATOR ENERGY RECOVERY VENTILATOR ERV 60H Part no. 606 (TOP PORTS) Part no. 60 (SIDE PORTS) 5 to 05 CFM (0. in. w.g.) VB0073 AN INGENIOUS AIR EXCHANGE SOLUTION THAT S AS VERSATILE AS IT IS COMPACT! Configured

More information

Address of your installer

Address of your installer User Manual VB0038 HRV / ERV Ventilation Systems PROTECH MODELS 84-HRV100 84-HRV200 84-ERV100 84-ERV200 Address of your installer 04187-03/11/15 ABOUT THIS MANUAL/PRODUCT The purpose of this manual is

More information

Tech to Tech May 07 HRV s & ERV s

Tech to Tech May 07 HRV s & ERV s Tech to Tech May 07 HRV s & ERV s Make daily deposits to your box of knowledge, soon it will have many reference cards. --Randal S. Ripley With the cost of energy going up all the time, home owners and

More information

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible HRU ECO 4 System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible Weight As a result of the unique clamping construction in combination with the plastic/synthetic

More information

10-year industry best core warranty. 5-year warranty on balance of unit.

10-year industry best core warranty. 5-year warranty on balance of unit. MODEL TR MODEL FTURES MERV-8 filters Less than 1 watt stand-by power consumption Transformer/relay package allowing simple on/off control Plastic double collars for 6 or 8 direct duct connection (TR300

More information

Indoor Air Quality Product Brochure.

Indoor Air Quality Product Brochure. Indoor Air Quality Product Brochure Ventilation: A vital system for a healthy home All homes require adequate ventilation for the safety of their occupants and to remove excess humidity, airborne pollutants

More information

TEVHR. Heat Recovery Ventilator

TEVHR. Heat Recovery Ventilator TEVHR Heat Recovery Ventilator Contents Teknogen Who we are, what we do? TEVHR... 1 Unit Specifications... 2 Performance Data... 3 Technical Specification... 5 Components... 6 Dimensions... 7 Duct Connection

More information

INDOOR AIR QUALITY KITS AND ACCESSORIES /2014. Supersedes 06/2014

INDOOR AIR QUALITY KITS AND ACCESSORIES /2014. Supersedes 06/2014 INDOOR AIR QUALITY KITS AND ACCESSORIES 507363-01 08/2014 Supersedes 06/2014 HEALTHY CLIMATE HRV & ERV VENTILATORS INSTALLATION INSTRUCTIONS & HOMEOWNERS GUIDE FOR HEALTHY CLIMATE HEAT RECOVERY VENTILATOR

More information

PHRV(R) Series. Heat Recovery Ventilator PHRV 140 PHRV 150 PHRV 200 PHRVR 155 PHRVR 160 PHRVR 205 PHRVR 210 PHRVR 305

PHRV(R) Series. Heat Recovery Ventilator PHRV 140 PHRV 150 PHRV 200 PHRVR 155 PHRVR 160 PHRVR 205 PHRVR 210 PHRVR 305 PHRV(R) Series Heat Recovery Ventilator PHRV 140 PHRV 150 PHRV 200 PHRVR 155 PHRVR 160 PHRVR 205 PHRVR 210 PHRVR 305 IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation,

More information

SHR & VHR Models. SHR & VHR Series. Installation Manual. Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

SHR & VHR Models. SHR & VHR Series. Installation Manual. Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT Installation Manual IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will operate if connected to any other

More information

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WGERV-A3 WGERV-C3 WGERV-A5 WGERV-C5 BARD MANUFACTURING COMPANY Bryan, Ohio 4356 Since 1914...Moving ahead, just as planned. Manual:

More information

FOR MODELS: VENMAR 1.3, 1.8 & 2.6 HE VENMAR 3055 & 5585 COMPACT vänee 1000, 2000 & 3000 HE

FOR MODELS: VENMAR 1.3, 1.8 & 2.6 HE VENMAR 3055 & 5585 COMPACT vänee 1000, 2000 & 3000 HE Installation Manual FOR MODELS: VENMAR 1.3, 1.8 & 2.6 HE VENMAR 3055 & 5585 COMPACT vänee 1000, 2000 & 3000 HE VB0021 10/2004 04435 Table of contents 1.0 Sizing.............................................................3

More information

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2. RANGE HOODS ATTIC VENTILATORS AIR EXCHANGERS DELUXE RANGE HOODS For more than 25 years, Venmar Ventilation has been one of North America s leading manufacturers of innovative Indoor Air Quality products

More information

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating. capacity: Heating capacity: 20,8 to 135,1 kw 22,6 to 144,7 kw Scroll compressors R-410A refrigerant Confi guration fl exibility Silent operation DESCRIPTION The AirDuo cooling units and are units which

More information

Offices. Conference halls. Kindergartens Libraries. Restaurants. Schools. Sport halls. Shops

Offices. Conference halls. Kindergartens Libraries. Restaurants. Schools. Sport halls. Shops Offices Conference halls Kindergartens Libraries Restaurants Schools Sport halls Shops 2 VENTS. SOUND-INSULATED VENTILATION TT SILENT-M 5-213 WWW.VENTILATION-SYSTEM.COM «NOISY LIFE» Our life is daily filled

More information

Ventilation Solutions IAQ Canada

Ventilation Solutions IAQ Canada Ventilation Solutions IAQ Canada 2 IAQ Canada Indoor Air Quality Keep your family safe What s All The Talk About Indoor Air Quality? What The Experts Say: You ve heard it on TV and read about it in magazines.

More information

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС HEAT RECOVERY AIR HANDLING UNITS Series VUT R TN H ЕС VUT R TN EH ЕС HEAT-RECOVERY VENTILATION Two-Stage Energy Saving System: HEATING COOLING Stage 1: Heat energy recovery by means of the rotary heat

More information

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater SUPPLY UNITS Series VENTS PA E Series VENTS PA W A13 control panel A13 control panel Suspended air supply units with the air capacity up to 3350 m 3 /h in the sound- and heat-insulated casing with the

More information

INDOOR AIR QUALITY KITS AND ACCESSORIES /12 Supersedes 05/12

INDOOR AIR QUALITY KITS AND ACCESSORIES /12 Supersedes 05/12 INDOOR AIR QUALITY KITS AND ACCESSORIES 506239 01 Supersedes 05/12 Litho U.S.A. HEALTHY CLIMATE HRV & ERV VENTILATORS INSTALLATION INSTRUCTIONS & HOMEOWNERS GUIDE FOR HEALTHY CLIMATE HEAT RECOVERY VENTILATOR

More information

SH, VH & SE Series. Installation, Operation and Maintenance Manual. Heat & Energy Recovery Ventilators SH 704 VH 704 SE 704

SH, VH & SE Series. Installation, Operation and Maintenance Manual. Heat & Energy Recovery Ventilators SH 704 VH 704 SE 704 Installation, Operation and Maintenance Manual Item #: 403165 Rev Date: 2017-09-26 SH, VH & SE Series Heat & Energy Recovery Ventilators SH 704 VH 704 SE 704 Your ventilation system should be installed

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS User Manual READ AND SAVE THESE INSTRUCTIONS VB0140 vänee 2000 HE 3000 HE VENMAR 1.8 HE 2.6 HE These products earned the ENERGY STAR by meeting strict energy efficiency guidelines set by Natural Resources

More information

Heat Recovery Energy Recovery Total Recovery Ventilators. Balanced Ventilation for Residential and Commercial Buildings. Advancing Ventilation

Heat Recovery Energy Recovery Total Recovery Ventilators. Balanced Ventilation for Residential and Commercial Buildings. Advancing Ventilation Heat Recovery Energy Recovery Total Recovery Ventilators Balanced Ventilation for Residential and Commercial Buildings Advancing Ventilation HRV-ERV-0517 May 2017 Common Ventilation Issues for Homes and

More information

WHHR Midi & Midi Lite

WHHR Midi & Midi Lite WHHR Midi & Midi Lite Residential Whole House Heat Recovery Units with Low Energy EC Motors Optional - Integral LCD Installation, Operating and Maintenance Instructions Image of model with LCD screen Page

More information

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE NEW ECO RANGE MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) Mechanical Ventilation with Heat Recovery Proud to Build British u Nuaire is a world leader in the design and manufacture of fans and ventilation

More information