CASE HISTORY NO. U1609 / U1640 FEB. / SEPT. 2009
|
|
- Kerry Horton
- 5 years ago
- Views:
Transcription
1 NO. U1609 / U1640 FEB. / SEPT ESKOM Koeburg Nuclear Power Station Cape Town, South Africa UNITS: Generator Hydrogen Coolers (13) 108 finned tubes per cooler, Admiralty Brass 24mm OD x 1.2mm wall thickness End-step erosion caused by plastic inserts and high-flow erosion/corrosion at tube ends. Installation of 2,808 Shield/Seals, 200 mm long, into inlet and outlet tube ends. Material used was 70/30 CuNi, required due to the extent of erosion/corrosion of the Brass tubes.
2 NO. U-3057 MAY 2009 Lower Colorado River Authority TC Ferguson Power Plant Marble Falls, TX Turbine Surface Main Condenser Air Cooling Section Two Waterboxes with 391 tubes each, 304SS 1 O.D. x.035 w.t. x long Air Cooling section of both waterboxes suffering from advanced erosion/corrosion and related tube pluggage. LCRA cut a large enough hole in both waterboxes to enable CTI Technicians to install and hydraulically expand 782 Full Length Tube Liners manufactured from 316L SS material into all designated tubes in both waterboxes. All previously plugged tubes were returned to service enabling this section of the condenser to operate at full capacity. Resultant success of this installation has led plant engineers to consider installing Liners in the main body of this unit.
3 NO. U-3110 DECEMBER, 2009 Winnetka Electric Plant Village of Winnetka, IL Main Condenser 2,180 Admiralty Brass tubes 7/8 O.D. x 18 BWG x 15 long Severe full-length problems from both pitting and also ammonia grooving. The problem is compounded by a total lack of access to the condenser because of a recently installed Caterpillar Diesel Generator located only feet from the tubesheet. CTI was able to restore over 225 previously plugged tubes to full service by installing our Full Length Tube Liners through the crank-case of the large diesel generator. The flexibility of the thin-walled Brass Liners allowed for 100% of the targeted tubes to be restored. A re-tubing of the condenser would have been impossible without moving the generator.
4 NO. R-3019 APRIL, 2009 Chevron Performance Contractors Pascagoula Refinery Pascagoula, MS Overhead Condenser 220 tubes per unit, 8 units 1 O.D. x 14 BWG x 36 long finned SA-179 tubes Severe wall loss and full-length pitting on the tube ID s, resulting in an overage of plugged tubes. CTI installed over 270 Full Length Tube Liners constructed from Alloy C-276 material into failed tubes only, returning them to normal operating service. All work was performed in-situ at the elevated overhead exchangers. The tube ID s had been gritblasted and Eddy Current tested prior to our arrival and work was completed though inlet and outlet header box plug holes.
5 NO. R3223 DECEMBER 2009 ESSO (via Foure Lagadec Mediteranee OEM) Fos Sur Mer Refinery Fos Sur Mer, France E-2212 Fin-fan units (2) 243 tubes each, Carbon Steel 1 O.D. x 14 BWG x 30 long Integrity of existing bundles forced the plant to modify their design. The original tube wall thickness was reduced from 10 BWG to 14 BWG and included the addition of CTI Full Length Tube Liners with.028 wall thickness. CTI fitted 486 Full Length Tube Liners into new fin-fan units, made of Alloy C276 in order to increase reliability and extend the life of the Carbon Steel units. All work was performed through header box plug holes.
6 NO. R3074 DECEMBER 2009 ExxonMobil Baytown Refinery Baytown, TX WHB E-701 Claus D Boiler 475 tubes, SA178 Carbon Steel 2½ O.D. x.134 MW Sulfitic corrosion attacking the original Carbon Steel tubes at the inlet end resulting in premature failures and tube replacement. Installation of 475 CTI Shield/Seals manufactured from 316SS,.049 wall thickness x 36 in length. These Shields were hydraulically expanded into the new parent tubes the entire 36 and then mechanically expanded at both the tubesheet and exit end of the Shield. Ceramic tube ferrules, 10 in length were then installed inside the CTI Shields by a local contractor. This installation was critical path and completed in two back-toback 12 hour shifts.
7 NO. R3062 JUNE 2009 Flint Hills Resources Corpus Christi Refinery Corpus Christi, TX E03 10A Units A thru H fin-fan bundles 8 units with 233 tubes each (1864 total tubes) SA214 Carbon Steel 1 O.D. x.125 MW x 32 long Design Pressure: 45 psig Design Temperature: 350 F Eddy Current examination on 100% of the tubes revealed unexpected, excessive corrosion ranging from 25% to 75% tube wall loss. On an emergency basis, CTI was contracted to install 1864 Full Length Tube Liners manufactured from 316L material into all 8 bundles. Flint Hills engineers isolated two bundles at a time enabling CTI Technicians to remain at the site until all 8 bundles were completed. The repair was a resounding success and site Engineers posted a job review of the installation for access by all FHR personnel systemwide.
8 NO. R3099 AUGUST 2009 Singapore Refining Company Singapore Crude OH Fin-Fan Condensers (6) 178 tubes each, Carbon Steel 1½ O.D. x 12 BWG x 31 4 long Units have history of inlet-end erosion of Carbon Steel tubes. SRC elected to manufacture new tube bundles, then install CTI Shields into all inlet ends (1068) of the new tubes. Shields were 12 long with a wall thickness, made of 316SS. Based on the success of this installation, CTI returned to the same plant to install another 768 Shields in September `09, into newly retubed fin-fan units.
9 NO. I2104 JANUARY 2009 Shell Philippines Exploration (SPEX) Malampaya On Shore Gas Plant Batangas, Philippines E 211 Inlet Gas Heater 193 U tubes, A179 Carbon Steel 1 O.D. x 10 BWG x 11 2 straight leg Shell Side (St eam) Tube Side (Sour Gas) Operating Temperat ure 162º C 73º C Operating Pressure 3.5 barg 128 barg Severe external corrosion of bottom half of the unit, between the tubesheet and first support sheet. Additional damage was also detected up to the 4 th support sheet. Installation of CTI Shields made of 321SS, 10 6 long. Two wall thicknesses (.022 /.028 ) were supplied, using the heavier walled Shields into the more damaged tubes. All Shields were hydraulically expanded their full length followed by mechanical expansions. Plant removed/cut out existing division plate for unobstructed access to the tubesheet/tubes. (see photo) Upon completion of the job and a successful hydrotest, Shell s Sr. Maintenance Engineer said There will be no question about using the services of CTI again in the near future ( On Feb. 17, Shell awarded CTI a Purchase Order for the repair of another Gas Heater at Batangas)
10
11 NO. I JANUARY 2009 Qatar Electricity and Water Commission Ras Abu Fontas Distillation Plant Doha, Qatar UNITS: Multi-Stage Flash Evaporators (6) 14,406 tubes, Aluminum Brass 1-1/8 OD x.039 wt x 41 7 long Severe inlet-end erosion leading to tube leaks. Installation of 14,406 CTI Shields via hydroswage, 8 long made of 70/30 CuNi material. Due to the extent of erosion, collars were required on 15% of the tubes.
12 NO. I3089 JULY 2009 Celanese (Nanjing) Chemical Co. Nanjing, China HE 323 Vertical Acid Reboiler 812 tubes, Alloy C276 3/4 O.D. x.065 wall Thinning of outlet tube ends (hottest section) with up to 65% wall loss. Tubesheet/ligaments have active corrosion with tube to tubesheet welds corroded completely in some spots, weakening the joints and creating leaks. In an extremely critical situation, CTI fabricated within 48 hours over 800 tube end Shields,.028 wall thickness x 6 long, made of C276 material. Collars were also fabricated due to the extreme erosion/corrosion at the tube openings. Celanese expedited the air freight of material direct to Nanjing. CTI personnel hand carried all tools and equipment to China, arriving in Nanjing before a Purchase Order could even be issued. All Shields/Collars were installed via mechanical expansion into the outlettube ends and the unit then successfully hydrotested. CUSTOMER COMMENTS: I would like to extend my sincere thanks, on behalf of Celanese, to CTI for their understanding and timely support in this critical matter.you assisted us immensely in very prompt production of the inserts and timely shipment/packaging efforts which had to be worked through to ensure uninterrupted shipment into Nanjing. Thank you again for the valiant and supportive effort.
13 NO. I3012 MARCH 2009 Samsung Fine Chemicals Ulsan, Korea Flue Gas Heater EA tubes, 316SS 1 OD x 12 BWG x 15 long Inlet-end erosion/corrosion due to flue gas (SO3) CTI Korea installed 480 Shields,.028 wall thickness x 16 long, made of Alloy C276. Collars were required on all Shields due to extent of erosion in the tubesheet area.
BASCO U-TUBE & TANK IMMERSION HEAT EXCHANGERS. ...world leaders in heat transfer technology
BASCO U-TUBE & TANK IMMERSION HEAT EXCHANGERS...world leaders in heat transfer technology BW-533.indd 1 6/7/07 5:33:16 PM Standard Heat Exchanger Designs Deliver Cost Effective Performance To address the
More informationINDUSTRIAL HEAT EXCHANGERS
INDUSTRIAL HEAT EXCHANGERS COILS / INDUSTRIAL HEAT EXCHANGERS / NUCLEAR PRODUCTS Overview Certifications CRN Applications / Products Air Dryers Compressed Natural Gas Economizers Engine & Turbine Exhaust
More information1 Tan Chek Zin 2 Ng Wei Sing 3 Arni R. Tharakaram. ExxonMobil, Singapore. 4 Satoshi Koguchi Hitachi Japan 1
Author 1 Tan Chek Zin 2 Ng Wei Sing 3 Arni R. Tharakaram Organization ExxonMobil, Singapore 4 Satoshi Koguchi Hitachi Japan 1 Presenter Author Position Working Experience Organization 1 Tan Chek Zin Machinery
More informationINDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction
INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER Compact Design High Recovery Energy Efficient Stainless Alloy Construction Factory Packaged Integral Safety System ASME Constructed & Stamped
More informationFORTUNE SMART INDUSTRIL LIMITED PRODUCT CATALOGUE
FORTUNE SMART INDUSTRIL LIMITED PRODUCT CATALOGUE 2015.02 Version 6 Jimmy Chan FORTUNE SMART INDUSTRIAL LIMITED 8F International Garden B No.160 Tianmushan Road Hangzhou China Tel:86-571-85023341 Fax:86-571-85023549
More informationSB Series Brazed Plate Heat Exchanger Installation Manual
SB Series Brazed Plate Heat Exchanger Installation Manual HOT COLD Exploded view of Schmidt SB Brazed Plate Heat Exchanger. WARNING Before proceeding with installation and operation read entire manual
More informationModule 3: Liquid Fossil Fuel (Petroleum) Lecture 25: Refinery Equipments
1 P age Module 3: Liquid Fossil Fuel (Petroleum) Lecture 25: Refinery Equipments 2 P age Keywords: Pipe still heater, heat exchangers, distillation tower, pumps Refinery equipments Introduction In refinery,
More informationCONDENSER TUBE COMPARISON WINYAH 2. Leif Svensen P.E. Santee Cooper One Riverwood Drive Moncks Corner, SC 29461
CONDENSER TUBE COMPARISON WINYAH 2 By Leif Svensen P.E. Santee Cooper One Riverwood Drive Moncks Corner, SC 29461 CONDENSER TUBE COMPARISON WINYAH 2 By Leif Svensen P.E. Santee Cooper One Riverwood Drive
More informationSECTION PLUMBING EQUIPMENT
PART 1 GENERAL 1.1 SECTION INCLUDES A. Water heaters B. Packaged water heating systems C. Water storage tanks D. Water softeners E. Pumps F. Circulators 1.2 REFERENCES SECTION 22 30 00 PLUMBING EQUIPMENT
More informationNuclear Plant Efficiently Removes Calcium Carbonate From Condenser Tubes
Close Nuclear Plant Efficiently Removes Calcium Carbonate From Condenser Tubes Teresa Hansen, Section Editor The South Texas Project (STP) Nuclear Power Plant in Wadsworth, Texas, was put into operation
More informationMUE162 HEAT EXCHANGER
MUE162 HEAT EXCHANGER Design, Operation, Performance, Inspection, Maintenance and Repair H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E www.ictd.ae ictd@ictd.ae Course Introduction:
More informationBORSIG WASTE HEAT BOILERS FOR NITRIC ACID, CAPROLACTAM AND FORMALDEHYDE PLANTS PROCESS HEAT EXCHANGER. A Member of KNM Group Berhad
BORSIG PROCESS HEAT EXCHANGER WASTE HEAT BOILERS FOR NITRIC ACID, CAPROLACTAM AND FORMALDEHYDE PLANTS A Member of KNM Group Berhad The Company BORSIG Process Heat Exchanger GmbH (a member of the BORSIG
More informationFlammable Liquid: A liquid whose flashpoint is greaterless than 100 F when tested by closed-cup test methods.
ANSI/IIAR 2-2014 Addendum A Standard for Safe Design of Closed-Circuit Ammonia Refrigeration Systems Public Review Draft #3 Reviewers of Addendum A are welcome to comment on the changes in the standard,
More informationPIP PNE00004 Steam Trap Guidelines
July 2016 Piping PIP PNE00004 Steam Trap Guidelines PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities, this Practice has been prepared from
More informationMarine Heat Exchangers SALES SERVICE REPAIR
Marine Heat Exchangers SALES SERVICE REPAIR Heat Transfer Equipment THE BROADEST SELECTION AVAILABLE FOR GENERAL HEATING AND COOLING. PRODUC 104-32 Shell & Tube Heat Exchangers PRE-ENGINEERED FOR GENERAL
More informationHigh Capacity Instantaneous Steam Fired Water Heater
MODEL F High Capacity Instantaneous Steam Fired Water Heater Features Compact High Capacity Design Packaged System Water heater is factory assembled on an all welded steel mounting frame to save time and
More informationCONSIDERATIONS IN CONVERTING A DUAL SHELL OR A DUAL PRESSURE COAL FIRED PLANT CONDENSER INTO A COMBINED CYCLE PLANT CONDENSER
Proceedings of the ASME 2013 Power Conference POWER2013 July 29-August 1, 2013, Boston, Massachusetts, USA POWER2013-98062 CONSIDERATIONS IN CONVERTING A DUAL SHELL OR A DUAL PRESSURE COAL FIRED PLANT
More informationDesign and Construction Standards SECTION PLUMBING EQUIPMENT
SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES: A. Water heaters. B. Packaged water heating systems. C. Water storage tanks. D. Water softeners. E. Pumps. F. Circulators. 1.2 REFERENCES
More informationSafario Cooling Factory LLC
Safario Cooling Factory LLC Since 1999, Safario Cooling Factory LLC has been maintaining as a leading manufacturer of Commercial and Industrial HVAC coils, chilled water coils, chiller coils, steam coils,
More informationHeat Transfer Equipment
Heat Transfer Equipment THE BROADEST SELECTION AVAILABLE FOR GENERAL HEATING AND COOLING. PR ODUC Shell & Tube Heat Exchangers PRE-ENGINEERED FOR GENERAL APPLICATIONS SX2000 Pre-engineered fixed tubesheet
More informationMAGNETIC DRIVE PUMPS AMERICA S MOST VERSATILE LINE OF CENTRIFUGAL PUMPS THINK QUALITY...THINK DELIVERY...THINK PRICE
MAGNETIC DRIVE PUMPS AMERICA S MOST VERSATILE LINE OF CENTRIFUGAL PUMPS THINK QUALITY...THINK DELIVERY...THINK PRICE Seal-less Design Price Pump magnetically driven, seal-less pumps provide a leak-proof
More informationPotts Welding & Boiler Repair Co., Inc.
Potts Welding & Co., Inc. Welcome Potts Welding was founded by Walter Potts in 1929 as a boiler repair business. It was incorporated in 1965 in the state of Delaware and operated essentially unchanged
More information+91-8071681962 Pioneer Engineering Works http://www.heatexchangerpioneer.com/ We are engaged in Industry of Manufacturing & Supplying of heat exchangers, oil coolers, heat exchangers in Coimbatore, oil
More informationTechnically Driven Heat Exchangers
JC Equipments Pvt. Ltd Technically Driven Heat Exchangers Profile JC is the leading ISO-9001-2008 certified, ASME U & S Stamp Authorized Designer, Manufacturer and Exporter of Industrial Cooling Towers
More informationEnvironmentally Safe No Emissions
Safe, Sealless, 100% Leakproof Mixing for the Chemical & Sanitary Industries Environmentally Safe No Emissions Safe Mixing for the Chemical & Sanitary Industries Sealless Makes Sense Magnetic Drives offer
More informationSECTION ROTARY SCREW WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower
SECTION 15684 ROTARY SCREW WATER CHILLERS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15240 - Vibration Isolation. 2. 15540 - Pumping Equipment (HVAC) 3. 15711 - Induced Draft Cooling Tower B.
More informationSOFTWARE DEVELOPMENT FOR MECHANICAL DESIGN OF SHELL AND TUBE HEAT EXCHANGER
SOFTWARE DEVELOPMENT FOR MECHANICAL DESIGN OF SHELL AND TUBE HEAT EXCHANGER Dhaval. B. Upadhyay 1 1 Department of Mechanical Engineering,Sir Bhavshinhji Polytechnic institute Bhavnagar, Gujarat, Abstract
More informationInstallation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils
Installation, Operation and Maintenance Guide Steam Coil Installation, Operation and Maintenance Guidelines for the installation, operation and maintenance of the Heatcraft brand of steam heating coils
More informationFigure 1. Ejector cross-sectional drawing. Figure 2. Precondenser to left of vacuum flasher. pressure.
LESSONS FROM THE FIELD - EJECTOR SYSTEMS James R. Lines, Graham Corporation, USA, presents the problems associated with ejector system performance and subsequent solutions. Figure 1. Ejector cross-sectional
More informationD-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS
D-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS GENERAL: This document provides performance requirements and guideline information for Heat Exchanger equipment for Colorado College only, and is not
More informationExchangers. Air-cooled Heat. Exchangers
Hamon Process Heat Exchangers Air-cooled Heat Exchangers Hamon in a few words Hamon D Hondt factories Hamon offices and factories Hamon started its industrial activities in Europe (Belgium and France)
More informationFlo-Rite-Temp Instantaneous Steam/Water Heater
Steam/Water Heaters Steam/water heaters are typically classified as instantaneous, semi-instantaneous and tank-type. Temperature control can be defined as either feed-forward or feedback. Feedback systems
More informationSCHMIDT- BRETTEN GASKETED PLATE HEAT EXCHANGERS
SCHMIDT- BRETTEN GASKETED PLATE HEAT EXCHANGERS API Schmidt-Bretten Leadership in plate heat exchangers since 1879. API Schmidt-Bretten traces its roots to 1879 in Germany when company founder Wilhelm
More informationEXTREME VISION ENGINEERING CO.,LTD
COMPANY PROFILE EXTREME VISION ENGINEERING CO.,LTD Address:- 220/1, Moo 1, T.Nongbua, A Bankhai, Rayong, 21120, Thailand Tel:- +6638-961481 Fax:- +6638-961481 Email:- marketing@extremevision-thai.com Website:-
More informationSouth Seas Inspection (S) Pte Ltd
PRESENTATION October 2009 SSI, your essential business partner for comprehensive & professional Derrick Building, Inspection, Maintenance, Repair & Operational Services to the Oil & Gas, Marine & General
More informationA. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.
15684 ROTARY SCREW WATER CHILLERS ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 236423 An optional
More informationCity of Richland Stormwater Management Plan
City of Richland Stormwater Management Plan City of Richland Public Works Department 840 Northgate Drive Richland, WA 99352 2015 Nancy Aldrich Special Projects Coordinator City of Richland Public Works
More informationGROUP PRESENTATION 2016
GROUP PRESENTATION 2016 ABOUT US International Oil & Gas engineering group operating on two market segments : Downstream: Process Fired Heaters (Heurtey Petrochem) Upstream: Gas Treatment (Prosernat) PROCESS
More informationThere are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are:
Heating of Crude Oil 1.Introduction: There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are: Heat Exchangers. Tube Still Heaters (Furnaces).
More informationMechanical Engineering Department Sheet (1)
Benha University Heat and Mass Transfer Faculty of Engineering at Shoubra 3 rd Year (Power) Mechanical Engineering Department Sheet (1) (1) What is heat exchanger? Mention with brief description and sketches
More informationDiocese of Cleveland Facilities Services Corporation
Diocese of Cleveland Facilities Services Corporation BOILER MAINTENANCE and SERVICING SEASONAL MAINTENANCE - to be performed by trained boiler technician or boiler contractor only: 1. Disassemble the low
More informationE. Baffle Tray Column (or, Termed Shower Deck, No Holes, Caps, or Other Contact Devices)
252 Applied Process Design for Chemical and Petrochemical Plants E. Baffle Tray Column (or, Termed Shower Deck, No Holes, Caps, or Other Contact Devices) For counter flow, gas flowing up a column through
More informationPROVIDING PROCESS EQUIPMENT SOLUTIONS TO CUSTOMERS FOR OVER 160 YEARS
PROVIDING PROCESS EQUIPMENT SOLUTIONS TO CUSTOMERS FOR OVER 160 YEARS 160 YEARS OF EXCELLENCE SINCE ITS INCEPTION, STRUTHERS WELLS has grown into an internationally respected name for reliable process
More informationEnergy recovery from exhaust gases using Heat Pipe technology
Energy recovery from exhaust gases using Heat Pipe technology Energy recovery from industrial flue and exhaust gases can provide large amounts of valuable energy savings, together with significant reductions
More informationFlo-Rite-Temp Instantaneous Steam/Water Heater
Steam/Water Heaters Steam/water heaters are typically classified as instantaneous, semi-instantaneous and tank-type. Temperature control can be defined as either feed-forward or feedback. Feedback systems
More informationEfficiency & Savings through On-Line Chemical Cleaning
Efficiency & Savings through On-Line Chemical Cleaning SENTRO Technologies provides innovative cleaning services to the Refining, Petrochemical & Pipeline industries www.sentro-technologies.com USA UK
More informationIN THE MARINE INDUSTRY
H E A T E X C H A N G E R S BULLETIN NO. TIS-108A PRIME SURFACE HEAT EXCHANGERS PLATE & FRAME HEAT EXCHANGERS ALL-WELDED PLATE HEAT EXCHANGERS IN THE MARINE INDUSTRY THE heat transfer people H E A T E
More informationBoiler Basics: Design & Application Differences. Presented by Steve Connor July 30, 2014
Boiler Basics: Design & Application Differences Presented by Steve Connor July 30, 2014 What We Are Covering Today Understanding Boiler Load Boiler Manufacturing Requirements Design & Construction Details
More informationSECTION ROTARY SCREW WATER CHILLERS. B. Removal of Existing Refrigerant in Existing Chiller:
SECTION 15684 ROTARY SCREW WATER CHILLERS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15240 - Vibration Isolation. 2. 15540 - Pumping Equipment (HVAC). 3. 15711 - Induced Draft Cooling Tower. B.
More informationwww.greenspower.com.sg 1company profile G reens Power have been at the forefront of Waste Heat Recovery Technology since Edward Green first patented the Fuel Economiser in 1845. The business developed
More informationCase 6 Impact of Fouling Factor and Special Material for Heat Exchanger
Case 6 Impact of Fouling Factor and Special Material for Heat Exchanger Copy Right By: Thomas T.S. Wan ) Sept. 17, 2010 All Rights Reserved Case Background: A screw refrigeration system was originally
More informationEliminating Condensation and Resulting Corrosion. Sulphur Tail Gas and De-Gas Lines
Eliminating Condensation and Resulting Corrosion In Sulphur Tail Gas and De-Gas Lines By David R. Hornbaker, Controls Southeast, Inc. and Graham M. MacPherson, P.Eng., Millenia Resource Consulting Abstract
More informationLONGEVITY SOLUTIONS FEEDWATER HEATERS CONDENSERS HEAT EXCHANGERS PRESSURE VESSELS AIR PREHEATERS ISOLATION DAMPERS AFTERMARKET SERVICES AND PARTS
LONGEVITY SOLUTIONS FEEDWATER HEATERS CONDENSERS HEAT EXCHANGERS PRESSURE VESSELS AIR PREHEATERS ISOLATION DAMPERS AFTERMARKET SERVICES AND PARTS EXPERIENCE. KNOW-HOW. COMMITMENT. SPX HEAT TRANSFER AFTERMARKET
More information(2) 325 tpd York Chlorine Liquefier Systems
(2) 325 tpd York Chlorine Liquefier Systems The liquefier is a split bundle and serves as both the primary liquefier and the secondary liquefier. The total for each York system is 325 tons liquid Cl2,
More informationBASCO TYPE ES EXTENDED SURFACE PLATE FIN HEAT EXCHANGERS. ...world leaders in heat transfer technology
BASCO TYPE ES EXTENDED SURFACE PLATE FIN HEAT EXCHANGERS...world leaders in heat transfer technology Everything you want in a heat exchanger and less API Heat Transfer Basco Type ES Extended Surface Plate
More informationthe new standard in Heat Transfer Equipment Century Series Heat Exchangers
the new standard in Heat Transfer Equipment Century Series Heat Exchangers Pre-engineered & custom-engineered heat exchangers, designed to TEMA specs. Century Series HEAT Exchangers Design flexibility
More informationLIST OF MAJOR PROJECTS EXECUTED IN GAS STORAGE
Page 3 of 8 LIST OF MAJOR PROJECTS EXECUTED IN GAS STORAGE Sr. Name of the Customer Location EPC Contractor / TPI Agency Year 1 SAIL Bhilai Steel Plant Bhilai, India TUV 2011-12 (Paul Wurth India Pvt.
More informationLIFE MANAGEMENT OF FEEDWATER HEATERS AT KCPL
LIFE MANAGEMENT OF FEEDWATER HEATERS AT KCPL Bryan R. Becker, Ph.D., P.E. Associate Professor of Mechanical Engineering University of Missouri-Kansas City Kansas City, Missouri Richard E. Pearce Project
More informationOil and Gas Sector one stop solution provider
DPI SIMBA LTD Oil and Gas Sector one stop solution provider Specialised Engineering Services (SES) ISO CERTIFIED COMPANY www.dpisimba.com DPI SIMBA LTD ISO CERTIFIED COMPANY www.dpisimba.com Oil and Gas
More informationGandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]
Experiment 1 Study of fundamentals of Fluid Flow and Heat Transfer associated with Heat Exchangers Review questions (1) Significance of dimensionless numbers. (2) Define overall heat transfer coefficient.
More informationIn the first years of the 1950 decade, the MSF system was developed by the U.S.A. navy.
MULTI STAGE FLASH In the first years of the 1950 decade, the MSF system was developed by the U.S.A. navy. It showed a much better operation conditions than MED, specially in the scaling behavior, and was
More informationInstallation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers
Bulletin 1200/4 (Revised 5/12) Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers INNOVATORS IN HEAT TRANSFER I. INSTALLATION OF HEAT EXCHANGERS A. HEAT EXCHANGER SETTINGS 1)
More informationA. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.
B B11.0 DIVISION 08 - OPENINGS SECTION 08 17 00 INTEGRATED DOOR OPENING ASSEMBLIES Specifier Note: Coordinate and edit articles and paragraphs below to suit project requirements. Add section numbers and
More informationDOLPHIN FRESH WATER SHELL AND TUBE EVAPORATOR
DOLPHIN FRESH WATER SHELL AND TUBE EVAPORATOR INTRODUCTION Dolphin offers Shell & Tube Evaporators. These components utilize the latest technology tubing available. FRESH WATER DX SHELL & TUBE EVAPORATORS
More information4 route 147, C.P.33 Coaticook, Qc J1A 2S8
4 route 147, C.P.33 Coaticook, Qc J1A 2S8 TABLE OF CONTENTS INSTALLATION Nozzles p.3 Clearance for dismantling p.4 Foundations p.4 Foundation bolts p.5 Leveling p.5 Bolted joints p.5 Recommended bolt tightening
More informationA. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.
SECTION 23 70 00- CENTRAL HVAC EQUIPMENT PART 1: GENERAL 1.1 PURPOSE: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.
More informationBHEL Steam Generators Material Selection Overview by Veerendar Aluvala DM/BHEL/Trichy
BHEL Steam Generators Material Selection Overview by Veerendar Aluvala DM/BHEL/Trichy Presentation Summary Pulverised Coal Combustion (PCC) Design Aspects Boiler Parameters Drum Type Boilers OTSC Boilers
More informationProducts & Application
Products & Application 1 Agenda 1. Gasketed Plate Heat Exchanger 2. Wide Gap Plate Heat Exchanger 3. Semi-Welded Plate Heat Exchanger 4. LHEBloc (Welded PHE) 5. Spiral Heat Exchanger 6. Plate & Shell Heat
More informationModern Heat Exchanger - A Review
Modern Heat Exchanger - A Review Mr. Irfan Aiyubbhai Vohra 1, Prof. Azim Aijaj 2, Dr. B.B. Saxena 3 1 M.Tech Student, P.C.S.T. Bhopal,M.P. 2 Assosiate Professor, P.C.S.T. Bhopal,M.P. 3 H.O.D.Mechanical
More informationTube Skin Temperature Sensors
Tube Skin Temperature Sensors Flexible HEATER, FURNACE, & BOILER Temperature Sensors Tube Skin Temperature Monitoring for BOILERS, FURNACES, & HEATERS DAILY THERMETRICS ENGINEERED S by Daily Thermetrics
More informationCascade Refrigeration System for LPG Subcooling. Related Technical Data and Information for the Case:
Case-16 Cascade Refrigeration System for LPG Subcooling Copy Right By: Thomas T.S. Wan ( ) Mar. 28, 2003 All Rights Reserved Case Background: This is a case of using a cascade refrigeration system to subcool
More informationDaikin Water Cooling, Heating, and High Capacity Booster Coils
Installation and Maintenance Manual IM 900 Daikin Water Cooling, Heating, and High Capacity Booster Coils Group: Applied Air Part Number: IM 900 Date: February 2008 Types HI-F5, E-F5 2008 Daikin International
More informationSECTION PLUMBING EQUIPMENT
PART 1 GENERAL 1.01 SECTION INCLUDES A. Water heaters. B. Packaged water heating systems. C. Domestic water heat exchangers. D. Water storage tanks. E. Water softeners. F. Reverse osmosis equipment. G.
More information4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions
4201 Lien Rd Madison, WI 53704 TS-140F Revised 09-10 Owner s Manual Therma-Stor III Heat Recovery System Installation, Operation & Service Instructions Read and Save These Instructions Table Of Contents
More informationCHX Heat Recovery THE Solution. Steam Plant Systems, Inc.
S P S CHX Heat Recovery THE Solution Steam Plant Systems, Inc. Steam Plant Systems, Inc. 2 CHX THE SOLUTION Welcome & Introduction What is a Condensing Heat Exchanger? Design Considerations & Corrosion
More informationLESSONS LEARNT FROM TROUBLESHOOTING
LESSONS LEARNT FROM TROUBLESHOOTING INTRODUCTION A boiler with trouble can make the industry sick. It is necessary to stop living with problems. Interactions with manufacturer could help to find solutions.
More informationFT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS
STEAM TRAPS Steam Traps Steam Trap Model * Sizes 3/4, 1, 1 1 /2, 2, 3, 4 Connections NPT, SW, FLG Body Material Carbon Steel or 316SS Options Live Orifice Air Vent PMO Max. Operating Pressure 450 PSIG
More informationSemi-Instantaneous Indirect Fired Water Heater
MODEL BWX Semi-Instantaneous Indirect Fired Water Heater Use Boiler Water Or HTHW To Heat Domestic Water Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone
More informationGAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont.
ODV-B GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont. N8A5E5 TABLE OF CONTENTS HORIZONTAL PIPING... PAGES 1-10 WARNINGS...
More informationGreenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing
Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs 3/8, 1/2 and 5/8 inch OD Tubing March 2010 Custom Coils Custom Coils Configured to Meet Your Needs Greenheck is proud to offer a complete
More informationSERVICE MANUAL. For Service & Parts please call APK THERMAL at or SAFETY INSTRUCTION
SERVICE MANUAL Installation, Operation and Maintenance Manual for Standrd Pre-Engineered Shell & Tube Models BCF, HCF, HFF, SSCF & SX2000 Fixed Tube Sheet Heat Exchangers For Service & Parts please call
More information+91-8049676600 Unitech Heat Exchangers & Fabricators http://www.unitechheatexchangers.com/ We are the topmost manufacturer engaged in offering Heat Exchanger, Oil Cooler, Heat Exchanger Spare Parts and
More informationEXHAUST SYSTEMS COMMERCIAL CHIMNEY LINING SYSTEMS.
www.jeremiasinc.com GENERAL INFORMATION COMMERCIAL CHIMNEY LINING If an existing chimney is showing signs of wear and tear due to its age or no longer fulfills the requirements of a modern heating system,
More informationB - BEST O - ORIGINAL. R - Renown. N - Name. I n H e a t e r s
B - BEST O - ORIGINAL R - Renown N - Name I n H e a t e r s Comprehensive, Cost-Effective and Super-Efficient The Born Range of Products and Services Specialist Furnaces Hydrocracking Steam Reforming Sulfur
More informationOACS Outdoor Air-Cooled Central Chillers
OACS Outdoor Air-Cooled Central Chillers Proudly Made In The USA since 1977 A Complete Central Chiller System Complete Central Chiller system with Integrated Reservoir and Pump all mounted on a single
More informationThanks for your interest in. People and Products for Specialty Machining and Welding. Field Services Equipment Rental
Thanks for your interest in People and Products for Specialty Machining and Welding Field Services Equipment Rental Equipment Sales Custom Design George Sandora President Tony Sandora General Manager Exp:
More informationPIPING SYSTEM EQUIPMENTS
PIPING SYSTEM EQUIPMENTS Introduction Equipments are devices that provide power, process and store materials. Equipments in piping systems depend on the specific industries using them. Specialized equipment
More informationSECTION AIR COILS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 82 16 AIR COILS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in the section
More informationKM-900MAH KM-900MWH KM-900MRH KM-900MRH3
ISSUED: FEB. 21, 2001 REVISED: SEPT. 25, 2001 TM HOSHIZAKI MODULAR CRESCENT CUBER MODELS KM-900MAH KM-900MWH KM-900MRH KM-900MRH3 INSTRUCTION MANUAL IMPORTANT Only qualified service technicians should
More informationCORTEC. CORTEC
Case Study 1 How do you cut lay-up costs...25%... 50%... even 75%? A large processing plant in Texas was going to take a system out of service for two years and then bring it back on line. The system contains
More informationInstruction Manual HWR MODEL RESISTO-FLO ELECTRIC BOILER
Page 1 of 16 Instruction Manual HWR MODEL RESISTO-FLO ELECTRIC BOILER Page 2 of 16 FOREWORD The HWR Resisto-Flo Electric Hot Water Boiler is designed to provide a compact packaged unit requiring a minimum
More informationIf you have any questions, please feel free to contact me at (405) or via at
Marketing News M-183-2007 Date: August 7, 2007 To: All Branch Managers, Branch Sales and Service Managers, Distributor Principals, Distributor Sales and Service Managers, Regional Sales Managers and Regional
More informationwww. ElectricalPartManuals. com \/' INSTRUCTIONS WESTINGHOUSE RADIATORS DESCRIPTION '- INSTALLATION MAINTENANCE
FIG. 1. Westinghouse Single Radiators Mounted Perpendicular to the Wall of a Rectangular Tank on a 6,000 KVA Transformer THE WESTINGHOUSE RADIATOR is a highly efficient cooling unit which is designed for
More informationMedupi Unit 6 ACC hot cleaning: Method and results
Medupi Unit 6 ACC hot cleaning: Method and results Johannes Pretorius and Pieter Rosslee China International ACC user s group meeting 13-16 October 2015 Overview Background Medupi ACC hot cleaning - general
More informationTop performance when the going gets tough
Top performance when the going gets tough The Alfa Laval DuroShell plate-and-shell heat exchanger Sub-headline coming soon DuroShell plate-and-shell made tougher Alfa Laval DuroShell is a specially engineered
More informationSECTION CENTRIFUGAL WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower
SECTION 15682 CENTRIFUGAL WATER CHILLERS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15240 - Vibration Isolation. 2. 15540 - Pumping Equipment (HVAC) 3. 15711 - Induced Draft Cooling Tower B. Removal
More informationTechniques of Heat Transfer Enhancement and their Application. Chapter 4. Performance Evaluation Criteria for Two-Phase Heat Exchangers
Chapter 4 Performance Evaluation Criteria for Two-Phase Heat Exchangers Prof. Min Zeng 1/50 1. Introduction 2. Operating Characteristics of Two-phase Heat Exchangers 3. Enhancement in Two-Phase Heat Exchange
More informationBoiler Condensate Return Basics. Presented by Steve Connor February 24, 2016
Boiler Condensate Return Basics Presented by Steve Connor February 24, 2016 What We Are Covering Today? Brief review of the total steam system Why a proper condensate return system is so important Condensate
More informationOPERATING INSTRUCTIONS
TECHNICAL INFORMATION OPERATING INSTRUCTIONS BITZER AUSTRALIA BUFFALO TRIDENT HEAT EXCHANGE Models PS1LE016 PS2LE233 Content 1 Important Recommendations 2 Safety Recommendations 3 Application Ranges 4
More informationCAT-SAC-2009(0) SARAVEL AIR COOLED CONDENSERS
CAT-SAC-2009(0) SARAVEL AIR COOLED CONDENSERS TABLE OF CONTENTS 2 Introduction....3 Selection Procedure.....4 Ratings.... 5-9 Correction Factors.....10-11 Application Data...12 Physical & Electrical Data...13
More information