1 Service & Installation Instructions Keep this booklet for Future Reference BLF SERIES BLF-CR SERIES BLF-RB SERIES KBC SERIES For Additional Copies Please Contact: Hillphoenix Barker Specialty Products 703 Franklin Street P.O. Box 478 Keosauqua, Iowa Tel: 319/ Fax: 319/ Or Visit: Updated 09/23/11

2 Table of Contents General Information Case Descriptions Shipping Information Case Sections BLF Service Series BLF Self-Service Series BLF Cake Deco Series BLF-RB Series KBC Service Series KBC Self-Service Series Mechanical View Installation Instructions Location Crate Removal Compressor Drain, Electrical and Refrigeration Connections for remote Cases Cases Exterior Loading Leveling Joining Lineup Doors Glass Adjustment Shelving Installation Checklist Cart Bumper Installation Electrical Information Amperage Information Wiring Color Code Timers Ballast Information Maintenance Information Cleaning Light Bulb Replacement Load Limits Service Evaporator Coil Layout Compressor Layout Service Cases Preventative Maintenance Trouble Shooting Guide Service Department Parts Warranty Refrigeration Information Case Operation Typical Component Settings Refrigeration Loads Electronic Thermostat IMPORTANT!! KEEP FOR FUTURE REF - ERENCE

3 General Information This booklet contains information on: BLF SERVICE SERIES BLF-D Non-Refrigerated, 49 Service Bakery Case with Front Lifting Glass BLF-SC Self-Contained, 49 Service Bakery Case with Front Lifting Glass BLF-R Remote, 49 Service Bakery Case with Front Lifting Glass BLF SELF SERVICE SERIES BLF-SD Non-Refrigerated, 49 Self-Service Bakery Case BLF-SS Self-Contained, 49 Self-Service Bakery Case BLF-SR Remote, 49 Self-Service Bakery Case BLF-BB Non-Refrigerated, 49 Self-Service Bakery Case BLF-RB Non-Refrigerated, 49 Self-Service Bakery Case BLF-CD Non-Refrigerated, 49 Self-Service Bakery Case BLF-CS Self-Contained, 49 Self-Service Bakery Case BLF-CR Remote, 49 Self-Service Bakery Case KBC SERVICE SERIES KBC-D Non-Refrigerated, 54 ¾ Service Bakery Case KBC-S Self-Contained, Refrigerated 54 ¾ Service Bakery Case KBC-R Remote, Refrigerated 54 ¾ Service Bakery Case KBC SELF-SERVICE SERIES KBC-SD Non-Refrigerated, 54 ¾ Self-Service Bakery Case KBC-SS Self-Contained, Refrigerated 54 ¾ Self-Service Bakery Case KBC-SR Remote, Refrigerated 54 ¾ Self-Service Bakery Case The BLF & KBC Series has been approved for the following standards: Shipping Information IMPORTANT! FOR YOUR PROTECTION PLEASE READ AND OBSERVE THE FOLLOWING INSTRUCTIONS: Transportation companies assume all liability from the time a shipment is received by them until the time it is delivered to the consumer. Our liability ceases at the time of shipment. All shipments leaving our plant have been carefully inspected. If a shipment arrives with the crating or packaging damaged, have the carrier note the condition on the receipt. Check as soon as possible for concealed damage. If it is found that the shipment has been damaged in transit, please DO NOT return it to us, but notify and file a claim with the carrier at once. FAILURE TO FOLLOW THIS PROCEDURE WILL RESULT IN REFUSAL BY THE CARRIER TO HONOR ANY CLAIMS WITH A CONSEQUENT LOSS TO THE CONSUMER. If a UPS shipment has been damaged, retain the damaged material and the carton and notify us at once. WE will file a claim. GOODS SHOULD NOT BE RETURNED FOR CREDIT UNLESS AUTHORIZED BY OUR SALES DEPARTMENT.

4 Case Drawings BLF Series BLF-SD Series BLF-SS Mechanical

5 BLF-CR Series BLF-RB Series BLF-RB Dry Series

6 KBC Series KBC-SS Series BLF Mechanical KBC Mechanical

7 Installation Instructions Location This refrigerated display case has been designed for displaying and the storage of perishable food product. It is engineered for air-conditioned stores with a maximum ambient of 75 F and 50% relative humidity. When selecting the location for placement of this case, avoid the following conditions: Excessive air movement Doors Air-conditioned vents Other air sources Excessive heat Windows Sun Flood lamps 8 feet or less from the product Other heat sources NOTE: A 12" clearance is necessary for condenser coil to run correctly. Do not block. Crate Removal Move case as close as possible to its location. Loosen the plastic dust cover from the pallet, but leave cover over the case to protect it while removing the case from the pallet. Carefully lift case up and off pallet being careful that leveling pads clear the pallet. Slide pallet from under case. Shipping blocks are attached to pallet and do not need to be removed. Note: Locate the horizontal supports underneath of unit before removing from pallet, damage to the finished metal will occur if correct lift points are not identified prior to removal. Drain, Electrical and Refrigeration Connections on Remote Cases NOTE: Barker remote units are shipped with a dry nitrogen charge of approximately 10 lbs. pressure in the evaporator coil. During installation if nitrogen charge is not present, leak check accordingly 1. See the mechanical views on Page 5 for drain access locations. Connect the PVC drains (or the copper drains) to existing floor drains. Traps are shipped at the factory within the case. ALL DRAINS MUST BE TRAPPED. Provide as much downhill slope as possible and avoid long runs of drain lines. Do not install condensate drains in contact with non-insulated suction lines in order to prevent condensate from freezing. 2. Electrical connections are made through the power supply box of each case, which can be accessed by removing the back panel. Voltage requirements and component amperage can be found in the electrical section of this manual, but always check the data tag located on the exterior of the case. CASE MUST BE GROUNDED. 3. Refrigeration connections are made through the refrigeration access cut out (see mechanical views). See refrigeration information section of this manual for caseloads and recommended settings. Refrigeration lines may be headed together for all cases in a lineup, if desired, by lines through the access area under the case. Refrigeration lines need to be connected in the lower refrigeration compartment or through the toe kick area. Do not run lines through the evaporator coil area shown to the right. ALL LINES MUST BE CORRECTLY SIZED. For proper refrigeration performance, PRODUCT MUST NOT BE PLACED IN A POSITION WHERE IT MAY AFFECT THE AIR CURTAIN. Air discharge and return air vents must remain unobstructed. Compressor All Self-Contained cases are equipped with a shipping block under the compressor. This block must be removed upon installation. Failure to remove the block will result in excessive noise, refrigeration leaks and will void warranty protection. Loosen all four nuts on the compressor hold down screws. Lift or pry the compressor up and remove the shipping block. Do not retighten screws, as the compressor should be left free to float on the spring mounts.

8 Case Exterior Loading These cases are not designed for excessive external weight. DO NOT WALK ON TOP OF THE CASE. Walking on top of cases could cause personal injury and damage to the case. Leveling To ensure proper operation of the refrigeration system and drainage of the condensate, THE CASE MUST BE LEVEL. Use a carpenter level-to-level front to back and side to side. Use the adjustable leveling legs to level case. Joining Lineups 1. Begin all lineups leveling from the highest point of the store floor. 2. To access bolt-holes, remove outside back lower panel, bottom deck, and top bolt cover located in the canopy of the case. 3. Apply foam tape to facing ends of lineup. Level second case to first case and seal with a good grade silicone on all edges of each case. 4. Line up bottom bolt holes in lower front and back of case (bolts are shipped in the case). Slide cases together. Insert lower bolts and place nuts on bolts. Tighten. THE FRONT OF THE CASES MUST BE FLUSH! 5. Remove the top bolt cover, located in the canopy of the case. Ensure that case is properly leveled so that the bolt holes align over the bolt holes in the adjoining case. Shim as necessary. 6. Tighten bolt in case top and replace bolt cover. Ensure all bolts are fastened tightly. Doors Rear doors are shipped inside the case. Push the top of the doors all the way into top door tracks. Push bottom of door over bottom door tracks and lower over tracks. Doors are labeled inside and outside for easy installation. Glass Adjustment The front lift glass on this case is installed at the factory with the case perfectly level. If adjustments need to be made to align the glass first check to insure the case was properly leveled during installation. NOTE: THIS IS A 2-PERSON OPERATION. ONE PERSON MUST HOLD THE GLASS AT ALL TIMES. 1. Lift the glass to its highest position as shown in drawing to the right. 2. Loosen allen screws. See profile left. 3. Slide glass right or left until the glass is even and is recessed into the aluminum extrusion. 4. Tighten the right allen screw while holding the left side of the glass firmly. Be careful to keep the glass level. 5. Tighten the remaining allen screws. 6. Lower glass into position. Repeat as necessary until glass is completely level. Remove access cover Remove bottom shelf to Lift hard - Remove lower back

9 Shelving Shelving is shipped separately. 1. Remove brackets, bars, lights, and/or tag molding from packaging. 2. Insert brackets into Lozier channel at desired height (Photo 1). Insert by angling up and then down. Begin with bottom shelf brackets. Insert middle and then top brackets. 3. Place support bars over screws. (Photo 2) There may be 1 to 3 bars per shelf depending on the width of the shelf. Fit from back of shelf to front. Note: If fitting for wire shelves, some bars will have clips on the center of the bar to hold the wire shelves in place. For shelves less than 18" wide, the clip should be placed in the back position. For shelving more than 18" wide, the clip should be positioned in the middle. All clips should face the back of the case. 4. Place tag molding on the front of the brackets in the same manner as the bars. 5. Under-shelf lights are not interchangeable. Determine bottom, middle and top light by lining up lights by cord length. Place longest cord length on bottom shelf, middle length on middle shelf and shortest cord on top shelf. Place light over brackets and behind the tag molding as shown (Photo 3). 6. Plug in lights. (Photo 4) Plug must be fully seated for lights to work. If one plug is loose, all lights will fail. Place cord in clip on bracket. 7. Place glass shelving on shelf brackets and bars. If wire shelves are used, place shelf over clip to hold in place. Photo 1 Photo 2 Photo 3 Photo 4 Installation Checklist Before supplying electrical power and starting case check the following: 1. Compressor Area (For Self-contained cases). Remove shipping block on units with semihermetic compressors. Check location of controls. 2. Evaporator Area. Check to ensure evaporator fan pressure plates are secure and in proper position NOTE: Hinged portion of pressure plates are secured for shipping with mounting screws. Screws do not have to be removed for case operation but must be removed to use hinge. 3. Lighting System Check to ensure male plugs are completely inserted in female sockets and that all lamps are securely seated in light fixture. 4. Case Leveling Visually check case. If lift glass is out of adjustment or case looks out of square, use a carpenter's level and shim as needed. After supplying power to the case and starting unit: 1. Check to ensure all fans are operational. 2. Check all lights. 3. Check case temperature and adjust thermostat as needed. See refrigeration section of this manual for case settings.

10 Cart Bumper Installation Note: If merchandiser is ordered with cart bumper, step 1 & 2 are completed at the factory. then snap bottom portion into place and slide bumper against the end cap for a flush fit. Continue to hook bumper onto base track with your hand or using a rubber mallet until you reach other end cap. NOTE: Cover mallet with a cloth to prevent marring the bumper finish. Cut plastic base to desired length of fixture. When using end caps be sure to cut base 3/4 short of fixture edge. When using corners, be sure to cut base so that it is flush with fixture edge. secure base to fixture with screws every 4 on center. Make sure to put a screw 3/8 away from the cut end of base. Mark and cut tail end of flexible bumper at least 1/8 longer then beyond the end cap position. NOTE: Make sure the end cut is straight and square for proper fit. Slightly retract the bumper in order to feed cut end into the end cap as you finish hooking the top and bottom edges of the bumper onto the base track. You should feel and hear the bumper snap into place for a snug fit. SNAP end caps or corners onto the base extrusion. Secure with #8 flat head phillips screws. Finally, check for proper fit and attachment along the entire length of bumper which is either on the wall or a fixture. Make sure you have a smooth and flush fit against the end caps. NOTE: Clean any dust or debris with a cloth and non abrasive cleaner. When installing flexible bumper top, the cut ends need to be as straight as possible. To mount on a curved or flat surface, start at one end and attach bumper to base by hooking bumper top onto track, Helpful Hints: Set the uncoiled flexible vinyl at room temperature 24 hours prior to installation. Over cut the flexible vinyl and compression fit. Adding the additional material will compensate for stretching which occurs during installation. Use a clean, dry cloth and any mild household cleaner or soap solution; spray and wipe clean

11 Refrigeration Information Case Operation Refrigeration The refrigeration in this case is thermostatically controlled. The case refrigerates until the cut out point on the thermostat is reached. The thermostat opens, cutting power to the liquid line solenoid. The compressor continues to run, the system pumps down causing the pressure switch to open, cutting power to the compressor. NOTE: Some cases may be ordered with EPR valves to control case temperature. Defrost These cases have two different types of defrost; hot gas and off cycle. The hot gas defrost system is time initiated; temperature and time terminated. The defrost timer energizes the defrost solenoid and de-energizes the liquid line solenoid. When the temperature in the case reaches 40, the defrost terminator thermostat de-energizes the hot gas solenoid. The system pumps down and the pressure switch cuts power to the compressor. The unit stays in off cycle defrost until the defrost timer re-energizes the liquid solenoid. NOTE: The evaporator fan runs continuously. With the off cycle defrost system, the timer cuts the power to the liquid solenoid causing the compressor to pump down to the cut out point on the pressure switch. The unit stays in off cycle defrost until the defrost timer re-energizes the liquid solenoid. NOTE: The evaporator fan runs continuously. Typical Component Settings 1. Thermostat cut out: 26-28, 2 differential Refrigeration Loads BLF-S and KBC-S Service Series BTU: 650 per linear foot Evap. Temperature: +20 Off Cycle Defrost 20"/4 hours BLF-SS and KBC-SS Self-Service Series BTU: 1150 per linear foot Evap. Temperature: +20 Off Cycle Defrost: 20"/4 hours BLF-CS BTU: 800 per linear foot (Wedge 3200) Evap. Temperature: +20 Off Cycle Defrost: 20"/4 hours NOTE: Remote Cases Defrost Cycle - 20"/ 4 HR Electronic Thermostat The electronic thermostat is located in the inside back of a self-service case (see photo 1) and in the rear lower refrigeration area in a service case (see photo 2). The thermostat is equipped with a liquid crystal display providing a constant readout of the sensed temperature. NOTE: The LCD display will be blank during defrost. A touch keypad that allows the users to select the set point temperature, differential and the heating/cooling modes. 2. Defrost Termination Thermostat: Bakery 40 Produce Evap Temperature: CRO valve: 404A A N/A 5. TXV: 8-10 Superheat 6. Pressure switch: 404A Low - 20 lb/ 55 lb High lb 134A Low - 7 lb/ 25 lb High lb NOTE: The above settings are approximate and will vary slightly with product load, lighting, store ambient conditions, etc. Evaporator fans run constantly.

12 Programming Steps for the ETC, Electronic Temperature Control All thermostats are pre-set and cycle checked at the factory. STEP 1: STEP 2: STEP 3: STEP 4: STEP 5: Press the set key once to access the Fahrenheit/Celsius mode. The display will display either F degrees Fahrenheit or C for degrees Celsius. Press the up arrow or the down arrow so the display indicates F. Press the set key again to gain access to the set-point. The LCD will display the current Set-point and the S1 will be blinking. Press the up arrow to increase or the down arrow to decrease the temperature setting. Press the set key again to gain access to the differential. The LCD will display the current differential and the DIF 1 will be blinking. This should be set at 2 F. Press the set key again to gain access to the cooling or heating mode. The LCD will display the current mode. Press either the up arrow or the down arrow to set the display in the C1, cooling mode. Press the set key once more and the programming is complete. Set the lock to keep the set point. STEP DISPLAY INDICATION F or C S1 (blinking) DIF (blinking) C1/H1 DESCRIPTION Fahrenheit or Celsius Scale Set-point Temperature Differential Temperature Cooling or Heating Mode

13 Electrical Information Remote Case Data - Electrical 120 Volt Model Evap Fans Cornice Lts Shelf Lts Anti-Sweat Heater HP Voltage 404A RLA/LRA 134A RLA/LRA Cond Fan Pan Heater Aux Glass Fans SERVICE BLF SERIES BLF NA 0.92 NA 1/ /51 9.1/ BLF NA 0.92 NA 1/ /51 9.1/ BLF NA 1.52 NA 1/ /51 9.1/ BLF NA 1.84 NA 3/ /60 13/ BLF NA 1.84 NA 3/ NA 5.3/ BLF NA 2.76 NA /40 NA BLF NA 2.76 NA /40 NA SELF-SERVICE BLF SERIES - FULL HEIGHT AND COUNTER HEIGHT BLF-48 SS NA 1/ /51 NA NA BLF-59 SS NA 3/ /60 13/ NA BLF-77 SS NA /40 NA NA BLF-96 SS NA 1 1/ /40 NA NA BLF-120 SS NA /55 NA NA BLF-144 SS NA /55 NA NA BLF-EW SS 0.43 NA 0.49 NA NA NA NA NA NA NA BLF-IW SS 0.43 NA 0.49 NA NA NA NA NA NA NA BLF CAKE DECO SERIES BLF-48 CR 0.43 NA / /51 9.1/ NA BLF-59 CR 0.43 NA / /51 9.1/ NA BLF-77 CR 0.86 NA / /60 13/ NA BLF-96 CR 0.86 NA /40 NA NA BLF-120 CR 1.72 NA / /40 NA NA BLF-144 CR 1.72 NA / /40 NA NA BLF-CR EW 1.72 NA NA NA NA NA NA NA SERVICE KBC SERIES Aux. Glass Fans KBC NA 0.92 NA 1/ /51 9.1/ KBC NA 0.92 NA 1/ /51 9.1/ KBC NA 1.52 NA 1/ /51 9.1/ KBC NA 1.84 NA 3/ /6 13/ KBC NA 1.84 NA 3/ NA 5.3/ SELF-SERVICE KBC SERIES KBC-48 SS NA 1/ /51 NA NA KBC-59 SS NA 3/ /60 13/ NA KBC-77 SS NA /40 NA NA KBC-96 SS NA 1 1/ /40 NA NA KBC-113 SS NA /55 NA NA DRY CASES - USE LIGHTING SPECIFICATIONS FROM REMOTE CASE DATA Additional Loads for Self-Contained Units Wiring Color Code Green Ground Black Hot White Neutral Red /220 Only Brown Interlock System Orange Thermostat Orange Liquid Solenoid Purple Hot Gas Defrost Purple Defrost Terminator Gray Light Switch Black/White Pressure Switch Off Cycle Timer Grasslin 1. White - Neutral 2. Black - Hot 3. Black - 4. Orange - Liquid Solenoid Parragon 1. White - Neutral 2. Black - Hot 3. Black - 4. Orange - Liquid Solenoid

14 Ballast Wiring Red Lights Yellow Lights Blue Lights NOTE: Case must be grounded SEE BALLAST DIAGRAM FOR EACH CASE Ballast Information Model Ballast Type Model Ballast Type BLF-48D BLF-59D BLF-77D BLF-96D BLF-113D (2) IOP-4P32SC 35TM (2) IOP-4P32SC 35TM BLF-48RB BLF-59RB BLF-77RB BLF-96RB BLF-118RB (1) IOP-3P32SC 35TM BLF-48CS BLF-59CS BLF-77CS BLF-96CS BLF-120CS BLF-144CS (1) IOP-3P32SC 35TM (1) IOP-3P32SC 35TM (1) IOP-3P32SC 35TM (3) IOP-3P32SC 35TM BLF-48CR BLF-59CR BLF-77CR BLF-96CR BLF-120CR BLF-144CR (1) IOP-3P32SC 35TM (1) IOP-3P32SC 35TM (1) IOP-3P32SC 35TM BLF-48SD BLF-59SD BLF-77SD BLF-96SD BLF-120SD BLF-132SD BLF144SD (2) IOP-4P32SC 35TM (2) IOP-4P32SC 35TM (2) IOP-4P32SC 35TM (3) IOP-4P32SC 35TM BLF-48SS BLF-59SS BLF-77SS BLF-96SS BLF-120SS BLF-132SS BLF144SS (1) IOP-3P32SC 35TM (1) IOP-3P32SC 35TM (3) IOP-3P32SC 35TM KBC-48D KBC-59D KBC-77D KBC-96D (2) IOP-4P32SC 35TM KBC-48R KBC-59R KBC-77R KBC-96R (2) IOP-4P32SC 35TM KBC-48S KBC-59S KBC-77S KBC-96S

15 Maintenance Information Cleaning Case Exterior Clean surfaces frequently with warm water and mild detergent. Do not use strong alkali solutions, steel wool, or abrasive cleanser. Non-Glare Glass Non-glare glass surfaces are coated to reduce the glare from lighting. Care must be taken not to scratch the coating. Use the following products only. Cleaning Cloths Scotch-Brite High Performance Cloth - manufactured by 3M and available in most grocery stores under the name Scotch-Brite Microfiber Cleaning Cloth in a 12" x14" size. This cloth is washable and may be reused as long as it remains clean. Spontex Microfibre Cleaning Cloth - distributed by Spontex and available in most grocery stores under the same name in a 15.75" x 12" size. This cloth is washable and may be reused as long as it remains clean. The cleaning cloths named above will normally remove dust, grease, oil and fingerprints without the need for cleaning fluids. A light spray of the cleaning fluids listed below will reduce the time required for cleaning. Cleaning Fluid - for more difficult cleaning jobs, these products are recommended: Windex - standard product only (extrastrength or specialty products may not be suitable) Glass-Plus - standard product only (extra-strength or specialty products may not be suitable) Warm Water DO NOT USE the following types of materials for cleaning glass with anti-reflective coatings. Coarse Paper Towels Scouring Pads or Powders Steel wool or Steel Fiber Materials Blades Acidic or highly Alkaline detergents Fluorine based detergents Plexiglas Use Novus 1 and Novus 2 to clean. Use Brillianize to polish. Contact factory to order. DO NOT use strong alkali solutions, steel wool, or abrasive cleanser. Evaporator Coil Clean as needed. Condenser Coil Clean condenser coil every three months or as needed with a whisk broom or vacuum. DISCON- NECT POWER WHEN SERVICING. FINS ON CONDENSER COIL ARE SHARP! Condensate Heater Add scale remover to condensate heater pan once every three months or as needed. Heater is designed for 75 and 50% relative humidity. The condensate pan may overflow if design limits are exceeded. Light Replacement The fluorescent lights in this case are furnished with plastic safety shields and end caps. When replacing fluorescent lamps, be certain to reinstall safety shield and caps. (See illustration). If the bulb is not fully seated the lights will not operate. BE SURE BULBS ARE FULLY SEATED. The light switch is mounted to the right side of the ceiling. See mechanical drawing for ballast box location. To remove bulb, grasp lamp holder on either end of the bulb and with equal pressure pull down. lamp holder cap A. bulb in safety tube B. Install new bulb into the plastic safety tube protector. Insert bulb into end cap. C. Position the bulb and cap under the lamp holder and with even pressure press the bulb into the light fixture. Caution: Failure to install bulb fully into light socket will cause premature bulb life and may cause damage to light fixture Load Limits DO NOT place product in the merchandiser until all refrigeration controls have been adjusted and are at the proper operating temperature. DO NOT place product above load limits or in such a way that the discharge or return air grill are blocked. This will effect the performance of the case and effect the defrost system Indicates load limit. Load Limit

16 Service WARNING! DISCONNECT THE ELECTRICAL POWER WHEN SERVICING OR REPLAC - ING ANY ELECTRICAL COMPONENT. Evaporator Coil Area 1. To gain access to evaporator area, remove bottom deck by lifting up and out to expose pressure plate cover and evaporator fans. 2. Remove screws as shown and lift pressure plate cover up as shown below. 3. Remove TXV cover to expose TXV. Typical BLF/KBC Self-Service Series Compressor Area B. D. E. H. F. G. I. J. A. C. A. Dissipater Pan B. Ballast Box C. Junction Box D. Compressor E. Receiver F. Thermostat G. Pressure Switch H. Filter Drier I. Site Glass J. Coil

17 Preventative Maintenance 1. Read the installation and Service manual. 2. See the trouble-shooting guide in the event of problems. 3. Contact Barker Company for an authorized service person in your area. Service Department - (319) Trouble Shooting Guide Problem: Action Case temperature is too warm. Case is in defrost. Review T-State Settings Product load may be over its limits Check case position in store. Ambient conditions may be affecting the case operation. Case temperature is too cold. The T-Stat Temp is set too low. Check case position in the store. Ambient conditions may be affecting the case operation. Case has condensation on glass. Check grill on die board for adequate airflow over the glass. Product load may be over its limits Check case position in the store. Ambient conditions may be affecting the case operation. Water has pooled under the case. Airflow is limited. Check the floor drain for clogs. check PVC drains under case for leaks. check condensate pan for malfunctioning parts. Check float, element, and switch. Product load may be restricting air flow. Check evaporator fans. Iced evaporator may impede airflow. Proximity to air ducts, opening window and doors may cause airflow to be disrupted. Self-Contained case makes excessive noise. Check to make sure that the shipping block under the compressor has been removed. Check that compressor mounting screws are not tight. Refrigerant leak Check to make sure that the shipping block under the compressor has been removed. Check that compressor mounting screws ar not tight.

18 Hillphoenix Barker Specialty Products Service Department IMPORTANT INFORMATION! FOR PROMPT SERVICE WHEN CONTACTING THE FACTORY FOR SUPPORT, BE SURE TO HAVE CASE MODEL AND SERIAL NUMBER HANDY. (THIS INFORMATION IS LOCATED ON THE DATA TAG ATTACHED TO THE CASE. SEE BELOW FOR DATA TAG LOCATIONS) For any warranty or service issues not covered by this manual, for tech support, or for warranty service calls, please contact the Barker Specialty Products Service Department at: (319) Parts Ordering Procedure 1. Contact the Service Parts Department Melissa Marshall 703 Franklin Street PO Box 478 Keosauqua, IA Tel: Fax: Provide the serial number of the case containing the part. To locate the serial number look on the data tag located on the customer left, outside back of the case, the customer left, inside top of the case, or contact the factory for location. BEFORE SERVICING ALWAYS DISCONNECT ELECTRICAL POWER AT THE MAIN DISCONNECT WHEN SERVICING OR REPLACING ANY ELECTRICAL COMPONENT. 3. If parts are to be returned for credit, contact the Parts Department. Do not send parts without authorization.

19 WARRANTY HEREINAFTER REFERRED TO AS MANUFACTURER FOURTEEN MONTH WARRANTY. MANUFACTURER S PRODUCT IS WARRANTED TO FREE FROM DEFECTS IN MATERIAL AND WORKMANSHIP UNDER NORMAL USE AND MAINTENANCE FOR A PERIOD OF FOURTEEN MONTHS FROM THE DATE OF ORIGINAL SHIPMENT. A NEW OR REBUILT PART TO REPLACE ANY DEFECTIVE PART WILL BE PROVIDED WITHOUT CHARGE. PROVIDED THE DEFECTIVE PART IS RETURNED TO MANUFACTURER. THE REPLACEMENT PART ASSUMES THE UNUSED PORTION OF THE WARRANTY. WARRANTY CLAIMS: All claims should include: the serial number of the cabinet, proof of purchase, date of installation, and all pertinent information supporting the existence of the alleged defect. Any action for breach of these warranty provisions must be commenced within one (1) year after that cause of action has accrued. All warranty service work must be pre-authorized by Barker Specialty Products ( ). Barker Specialty Products reserves the rights to designate the service provider, time in which labor is to be performed and specify amount of time per warranty problem. This warranty does not include labor or other costs incurred for repairing, removing, installing, shipping, servicing or handling of either defective parts or replacement parts. The fourteen month warranty shall not apply: 1. To any unit or any part thereof which has been subject to accident, alteration, negligence, misuse or abuse, operation on improper voltage, or which has not been operated in accordance with the manufacturer s recommendation, or if the serial number of the unit has been altered, defaced, or removed. 2. When the unit, or any part thereof, is damaged by fire, flood, or other act of God. 3. Outside the continental United States. 4. To labor cost for replacement parts, or for freight, shipping expenses, sales tax or upgrading. 5. When the operation is impaired due to improper installation 6. When installation and startup forms are not properly complete or returned within two weeks after startup. THIS PLAN DOES NOT COVER CONSEQUENTIAL DAMAGES. Manufacturer shall not be liable under any circumstances for any consequential damages, including loss of profit, additional labor cost, loss of any delay in its performance hereunder due to causes beyond its control. The foregoing shall constitute the sole and exclusive remedy of any purchases and the sole and exclusive liability of Manufacturer in connection with this product. The Warranties are Expressly in Lieu of All Other Warranties, Express of Implied and All Other Obligations or Liabilities on Our Part. The Obligation to Repair or Replace Parts or Components Judged to be Defective in Material or Workmanship States Our Entire Liability Whether Based on Tort, Contract or Warranty. We Neither Assume Nor Authorize any Other Person to Assume for Us Any Other Liability in connection with Our Product. Mail approved warranty claims to the address listed below: Hillphoenix Barker Specialty Products 703 Franklin Street, PO Box 478 Keosauqua, IA Tel: /Fax:

For Additional Copies Please Contact:

For Additional Copies Please Contact: Service & Installation Instructions Keep this booklet for Future Reference BWU SERIES BWU-BCC SERIES BWU-RB SERIES For Additional Copies Please Contact: Hillphoenix Barker Specialty Products 703 Franklin

More information

For Additional Copies Please Contact:

For Additional Copies Please Contact: Service & Installation Instructions Keep this booklet for Future Reference CWC SERIES CW SERIES HW SERIES SB SERIES SBI SERIES For Additional Copies Please Contact: Hillphoenix Barker Specialty Products

More information

For Additional Copies Please Contact:

For Additional Copies Please Contact: Service & Installation Instructions Keep this booklet for Future Reference BMD-48 SERIES BMD-51 SERIES BMD-54 SERIES BSD SERIES For Additional Copies Please Contact: Hillphoenix Barker Specialty Products

More information

Service & Installation Instructions Keep this booklet for future reference

Service & Installation Instructions Keep this booklet for future reference Service & Installation Instructions Keep this booklet for future reference BSD-SW SERIES BSD-T SERIES For Additional Copies Please Contact: Barker Specialty Products by Hill PHOENIX 703 Franklin Street

More information

For Additional Copies Please Contact:

For Additional Copies Please Contact: Service & Installation Instructions Keep this booklet for Future Reference PT SERIES PTD SERIES PTD-G SERIES PTD-H SERIES SD SERIES SD-G SERIES SD-H SERIES For Additional Copies Please Contact: Hillphoenix

More information

Service & Installation Instructions Keep this booklet for future reference

Service & Installation Instructions Keep this booklet for future reference Service & Installation Instructions Keep this booklet for future reference DLP SERIES GMD SERIES GSD SERIES SMD SERIES SSD SERIES For Additional Copies Please Contact: Barker Specialty Products by Hill

More information

Horizontal Bottle Cooler Installation and Operation Manual

Horizontal Bottle Cooler Installation and Operation Manual Speeds Up the Pace of Innovation Horizontal Bottle Cooler Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! TBC-50SD, 50SB/ TBC-95SD,

More information

RPI Industries, Inc.

RPI Industries, Inc. RPI Industries, Inc. AIR SCREEN and SELF-SERVE OPERATION AND SERVICE MANUAL WARRANTY INFORMATION For Models Olympus Bandit Bravo SCAS36R SCRFC3660R SCRFC3648R SCAS48R SCRFC4860R SCRFC4848R SCAS60R SCRFC6060R

More information

HANDBOOK O3EIF MEAT CASES INSTALLATION & OPERATION

HANDBOOK O3EIF MEAT CASES INSTALLATION & OPERATION HANDBOOK INSTALLATION & OPERATION O3EIF MEAT CASES Table of Contents General Information... 2 Using Casters... 3 Case Dimensions... 4 Case Operations... 5 Line Up & Trim Out... 6 Piping: Refrigeration

More information

RPI Industries, Inc.

RPI Industries, Inc. IMPORTANT: THE FOLLOWING INFORMATION SHOULD BE RETAINED FOR FUTURE REFERENCE RPI Industries, Inc. building a better case for sales BAKERY and DELI USE AND SERVICE MANUAL WARRANTY INFORMATION SPECIFICATIONS

More information

WCPT-3 and WCPT-4. Effective Date: 2017 IMPORTANT INFORMATION READ BEFORE USE. Drop-in Display Cases

WCPT-3 and WCPT-4. Effective Date: 2017 IMPORTANT INFORMATION READ BEFORE USE. Drop-in Display Cases WCPT-3 and WCPT-4 Service and Installation Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately.

More information

Field Top Mounted Condensing Unit

Field Top Mounted Condensing Unit Field Top Mounted Condensing Unit INSTALLATION & OPERATIONS MANUAL RF/RF-N, RM/RM-N IMPORTANT Keep in store for future reference! REVISION HISTORY VERSION 1.0 New manual This manual is specific to the

More information

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Turbo Air Speed up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Underbar Equipment Back Bars Installation and Operation Manual Please read this manual completely

More information

InstructIon Manual KrEs EQuIPMEnt stands

InstructIon Manual KrEs EQuIPMEnt stands Instruction Manual Instruction Manual SELF-CONTAINED AND REMOTE Kairak KRES model refrigerated equipment stand units are available in many lengths from 36 to 120 inches long. These units are available

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL INSTALLATION AND OPERATING MANUAL Refrigerated Merchandisers with Air-Over Displays Refrigerated Low-Profile Mobile Merchandiser Refrigerated High-Profile Mobile Merchandiser Refrigerated Grab-N-Go Merchandiser

More information

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual For service information call 800-544-3057 Please have the following information available before calling. Information can be found on

More information

RPI Industries, Inc.

RPI Industries, Inc. RPI Industries, Inc. AIR SCREEN and SELF-SERVE OPERATION AND SERVICE MANUAL WARRANTY INFORMATION For Models Stratus SCRFC48R-SSI SCRFC60R-SSI SCRFC72R-SSI SCRFC48R-SSII SCRFC72R-SSII SCRFC48R-SSIII SCRFC72R-SSIII

More information

ref. com Owner s Manual for models: A Step Above the Standard Thank you for choosing EVEREST

ref. com Owner s Manual for models: A Step Above the Standard Thank you for choosing EVEREST www.everest ref. com Owner s Manual for models: Back Bar Coolers " Deep Back Bar Coolers Glass Door Back Bar Coolers " Deep Galss Door Back Bar Coolers " Deep Galss Sliding Door Back Bar Coolers EBB3,

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL INSTALLATION AND OPERATING MANUAL Refrigerated Island Merchandiser FOR PARTS & SERVICE Contact: Piper Products, Inc. Phone: (800) 544-3057 Ask for Service Department IMPORTANT! This manual contains important

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL INSTALLATION AND OPERATING MANUAL Salad Bars Olive Bars Food Prep Cases Refrigerated Cases with Air-Over Displays Refrigerated Cases with Coppered Cold Well Displays Cases with Under-Counter Refrigerators

More information

RPI Industries, Inc.

RPI Industries, Inc. IMPORTANT: THE FOLLOWING INFORMATION SHOULD BE RETAINED FOR FUTURE REFERENCE RPI Industries, Inc. building a better case for sales CONFECTIONERY USE & SERVICE MANUAL WARRANTY INFORMATION For Models Bradford

More information

DELI MODEL: OSA & OSAG INSTALLATION & OPERATION HANDBOOK P052392H. Rev /09 COMPONENT

DELI MODEL: OSA & OSAG INSTALLATION & OPERATION HANDBOOK P052392H. Rev /09 COMPONENT DELI C A S E S MODEL: OSA & OSAG INSTALLATION & OPERATION HANDBOOK COMPONENT P052392H Rev. 14 05/09 Welcome to the Hill PHOENIX display case family. We re very pleased you joined us. This installation

More information

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER G-Series Cooler GCG-10 UPRIGHT COOLER Manual is for the following models: GCG-10-N33EB G-10-N33EB Instruction Manual Manual is for the following models: GCG-10-N33EB G-10-N33EB Instruction Manual GCG-10

More information

Milk Coolers Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

Milk Coolers Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! Turbo Air Speed up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Milk Coolers Installation and Operation Manual Please read this manual completely before attempting

More information

COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL

COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL Model No.: TGM-69R FEATURE CHART ADVERTISING PANEL FLOURESCENT SWITCH COOLING FAN FLOURESCENT LAMP EVAPORATOR INNER DRAIN PAN SHELF DOOR HANDLE GLASS DOOR CONDENSER

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL INSTALLATION AND OPERATING MANUAL Refrigerated Cases with Air-Over Displays Refrigerated High Profile Grab-N-Go FOR PARTS & SERVICE Contact: Piper Products, Inc. Phone: (800) 544-3057 Ask for Service Department

More information

ISLAND PRODUCE MODELS: OIP, OIPB, &OIPBB INSTALLATION & OPERATION HANDBOOK. P054956H Rev. 7 11/06 COMPONENT

ISLAND PRODUCE MODELS: OIP, OIPB, &OIPBB INSTALLATION & OPERATION HANDBOOK. P054956H Rev. 7 11/06 COMPONENT ISLAND PRODUCE C A S E S MODELS: OIP, OIPB, &OIPBB INSTALLATION & OPERATION HANDBOOK COMPONENT P054956H Rev. 7 11/06 Welcome to the ORIGIN 2 display case family. We re very pleased you joined us. This

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS SPECIALTY REFRIGERATED TRANSPORT CABINETS FOR SATELLITE LOCATIONS RBQ-96 Caution: Read the instructions before using the machine. CONGRATULATIONS......and thank you for purchasing

More information

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- 8610 Production Avenue San Diego, California 92121 (858) 566-7465 Fax (858) 566-1943 WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- Thank you for choosing a BREEZAIRE cooling unit. We believe

More information

GENERAL PURPOSE REFRIGERATORS ABT-9R, ABT-14R, ABT-17R, ABT-20R, ABT-30R

GENERAL PURPOSE REFRIGERATORS ABT-9R, ABT-14R, ABT-17R, ABT-20R, ABT-30R GENERAL PURPOSE REFRIGERATORS ABT-9R, ABT-14R, ABT-17R, ABT-20R, ABT-30R OWNER S INSTRUCTIONS This manual describes how to operate and care for your appliance to get the best, most efficient, performance.

More information

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers Blue Air Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers Please read this manual completely before installing or operating this unit! BACF11 BACF15 BACRF14 Blue Air reserves

More information

SERIES NIM. Low Temperature Merchandisers PLEASE READ THIS MANUAL BEFORE USING THE PRODUCT

SERIES NIM. Low Temperature Merchandisers PLEASE READ THIS MANUAL BEFORE USING THE PRODUCT SERIES NIM Low Temperature Merchandisers PLEASE READ THIS MANUAL BEFORE USING THE PRODUCT Hussmann Monterrey, Mexico Carretera Mexico-Laredo KM. 1009 Cienga de Flores, Nuevo Leon 65550 Mexico Phone: (52)

More information

IMPORTANT PLEASE RETAIN FOR YOUR RECORDS

IMPORTANT PLEASE RETAIN FOR YOUR RECORDS Beverage Air IMPORTANT INFORMATION FOR H SERIES HR/HF/HPR/HPF This cooler has passed the QUALITY CONTROL INSPECTION And meets the high standards at Beverage-Air This inspection includes complete refrigeration

More information

INSTRUCTIONS FOR OPERATION AND CARE OF. P.O. Box 3527 City of Industry, CA, , U.S.A

INSTRUCTIONS FOR OPERATION AND CARE OF. P.O. Box 3527 City of Industry, CA, , U.S.A INSTRUCTIONS FOR OPERATION AND CARE OF GLACIERFREEZE GF-12 P.O. Box 3527 City of Industry, CA, 91744-0527, U.S.A. 800-782-7706 626-968-6681 www.whitehallmfg.com Member of 6702-488-000 August 2012 WARNING

More information

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA G-Series Cooler COUNTERTOP COOLER Part No.11IPA-061000 Instruction Manual FOR YOUR FUTURE REFERENCE This easy-to-use manual will guide you in getting the best use of your cooler. Remember to record the

More information

Refrigerator Freezer Installation and Operation Manual

Refrigerator Freezer Installation and Operation Manual Speeds Up the Pace of Innovation CAUTION! Refrigerator Freezer Installation and Operation Manual PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Please read this manual completely before attempting

More information

INSTRUCTIONS! DO NOT DISCARD!

INSTRUCTIONS! DO NOT DISCARD! INSTRUCTIONS! DO NOT DISCARD! CAUTION! Do NOT install where injury might occur due to Moving parts, Sharp corners, Hot surfaces or electrical components dcn0620 Page 1 of 12 INSTALLATION INSTRUCTIONS CAUTION

More information

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER G-Series Cooler UPRIGHT COOLER Manual is for the following models: -N13EB G-9-N13EB -B13EB Instruction Manual FOR YOUR FUTURE REFERENCE This easy-to-use manual will guide you in getting the best use of

More information

INSTRUCTIONS! DO NOT DISCARD!

INSTRUCTIONS! DO NOT DISCARD! INSTRUCTIONS! DO NOT DISCARD! CAUTION! Do NOT install where injury might occur due to Moving parts, Sharp corners, Hot surfaces or electrical components dn0521 Page 1 of 12 INSTALLATION INSTRUCTIONS CAUTION

More information

Installation & Operation Manual Ice Cream Freezers

Installation & Operation Manual Ice Cream Freezers Installation & Operation Manual Ice Cream Freezers Please read this manual completely before installing or operating this unit! BACF11 BACF15 Blue Air reserves the right to make product modification at

More information

Glass Door Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

Glass Door Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! Turbo Air Speed up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Glass Door Merchandiser Installation and Operation Manual Please read this manual completely

More information

Installation and Operations Manual for HORIZONTAL DISPLAY MERCHANDISERS

Installation and Operations Manual for HORIZONTAL DISPLAY MERCHANDISERS Installation and Operations Manual for HORIZONTAL DISPLAY MERCHANDISERS 143539 Rev. A 07/11 TABLE OF CONTENTS INTRODUCTION 3 STORE CONDITIONS 3 WARNING LABELS AND SAFETY INSTRUCTIONS 4 PRE-INSTALLATION

More information

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA G-Series Cooler UPRIGHT COOLER Part No.11IPA-062800 Instruction Manual FOR YOUR FUTURE REFERENCE Thank you for using our product. This manual will guide you in getting the best use of your cooler. Remember

More information

WIRING DIAGRAM. This manual describes the unit features and explains how to set-up, operate and maintain these AirPac Models. COOLIT2600 COOLIT2900

WIRING DIAGRAM. This manual describes the unit features and explains how to set-up, operate and maintain these AirPac Models. COOLIT2600 COOLIT2900 WIRING DIAGRAM This manual describes the unit features and explains how to set-up, operate and maintain these AirPac Models. COOLIT2600 COOLIT2900 17 THANK YOU! WARRANTY INFORMATION Thank you for choosing

More information

Refrigerator Freezer Installation and Operation Manual

Refrigerator Freezer Installation and Operation Manual Speeds Up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING FREEZER Refrigerator Freezer Installation and Operation Manual Please read this manual completely before attempting

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MOBILE HEATED DISH CABINET TM HDC Series Stores, heats, and holds dishes. CONGRATULATIONS... HDC-252-I Heated model shown with flip back top opened....and thank you for purchasing

More information

User Manual. Commercial School Milk Cooler User s Manual. Commercial School Milk Coolers: MC34, MC49, MC58

User Manual. Commercial School Milk Cooler User s Manual. Commercial School Milk Coolers: MC34, MC49, MC58 Commercial School Milk Cooler User s Manual Commercial School Milk Coolers: MC34, MC49, MC58 12/2015 Please read the manual thoroughly prior to equipment set-up, operation and maintenance. - 1 - Exploded

More information

This manual describes how to operate and care for your appliance to get the best, most efficient, performance. READ THIS BOOK!

This manual describes how to operate and care for your appliance to get the best, most efficient, performance. READ THIS BOOK! STANDARD LABORATORY REFRIGERATORS ABT-10B, ABT-12B, ABT-19B, ABT-23B, ABT-26B, ABT-33B, ABT-35B, ABT-37B, ABT-41B, ABT-45B, ABT-47B, ABT-49B, ABT-69B, ABT-72B, ABT-30RG OWNER S INSTRUCTIONS This manual

More information

This manual describes how to operate and care for your appliance to get the best, most efficient, performance. READ THIS BOOK!

This manual describes how to operate and care for your appliance to get the best, most efficient, performance. READ THIS BOOK! GENERAL PURPOSE DUAL TEMP REFRIGERATOR / FREEZER MODEL NUMBERS: ABT-RFC-3M, ABT-RFC-12M, ABT-RFC-16M, ABT-RFC-17A, ABT-RFC-20A, ABT-RFC-30M OWNER S INSTRUCTIONS This manual describes how to operate and

More information

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com Read and Save These Instructions Horizon Galaxy - Installation and Operations Manual Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC 27505 www.horizondehumidif iers.com 1 Safety Notes: The Horizon

More information

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL www.polartemp.com TABLE OF CONTENT Disclaimer.......................................... Page 3 Inspection, unpacking and FMU setup.................. Page

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl100rnl, BFL125RNL Item Stock Number(s): BFL100RNL, BFL125RNL IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING

More information

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5 TABLE OF CONTENTS Warnings 2 Installation Instructions 3 Wiring Instructions 3 Mounting Instructions 4 Replacement Element Installation 5 Replacement Parts 5 Heater Coverage Areas 6 General Notes 6 Maintenance

More information

REFRIGERATOR AND FREEZER UNITS FOR HAZARDOUS LOCATIONS MODEL: LABH 30RX, 30FX, 30DTX, 20RX, 20FX, 17RX, 17FX, 14RX, 14FX OWNER S INSTRUCTIONS

REFRIGERATOR AND FREEZER UNITS FOR HAZARDOUS LOCATIONS MODEL: LABH 30RX, 30FX, 30DTX, 20RX, 20FX, 17RX, 17FX, 14RX, 14FX OWNER S INSTRUCTIONS REFRIGERATOR AND FREEZER UNITS FOR HAZARDOUS LOCATIONS MODEL: LABH 30RX, 30FX, 30DTX, 20RX, 20FX, 17RX, 17FX, 14RX, 14FX OWNER S INSTRUCTIONS This manual describes how to operate and care for your appliance

More information

3-DECK ISLAND PRODUCE INSTALLATION & OPERATION HANDBOOK. P053096D Rev. 9 11/10 COMPONENT

3-DECK ISLAND PRODUCE INSTALLATION & OPERATION HANDBOOK. P053096D Rev. 9 11/10 COMPONENT 3-DECK ISLAND PRODUCE C A S E S M O D E L S : O 3 I P & O 3 I P B INSTALLATION & OPERATION HANDBOOK COMPONENT P053096D Rev. 9 11/10 Welcome to the Hill PHOENIX display case family. We re very pleased

More information

G-10f/GCG-10f UPRIGHT COOLER

G-10f/GCG-10f UPRIGHT COOLER G-Series Cooler G-10f/GCG-10f UPRIGHT COOLER Manual is for the following models: G-10F, G-10-F33EB GCG-10F, GCG-10-F33EB GCG-10F2, GCG-10-F233EB G-10-F33EB-HC, GCG-10-F33EB-HC GCG-10-F233EB-HC Instruction

More information

QM5, QM5G Multi-Deck Meat Display Case. Part Number: 31E03028 Date: 08/13/2007

QM5, QM5G Multi-Deck Meat Display Case. Part Number: 31E03028 Date: 08/13/2007 Part Number: 31E03028 Date: 08/13/2007 5201 Transport Boulevard Columbus, GA. 31907 706-568-1514 Installation & Operation Manual QM5, QM5G Multi-Deck Meat Display Case IMPORTANT KEEP IN STORE FOR FUTURE

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS HLC WITH DIXELL CONTROLS Quick Start On Page 7 Detailed Operating Manual for Controller Included Separately HLC SERIES WITH RADIANT HEAT SYSTEM FWE HLC WITH DIXELL CONTROLS HLC-SL1826-5L

More information

Installation & Operations Manual

Installation & Operations Manual Installation & Operations Manual J - Version Master-Bilt Products 908 Highway 15 North New Albany, MS 38652 Phone: (800) 684-8988 5/16 Rev. E 029-91000 5/16 Rev. E 029-91000 2 TABLE OF CONTENTS INTRODUCTION....

More information

Glass Door Merchandiser Refrigerator and Freezer

Glass Door Merchandiser Refrigerator and Freezer Glass Door Merchandiser Refrigerator and Freezer (Swing and Sliding Door ) Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment.

More information

DELI MODELS: OSI, OWSI, OSIO & OWSIO INSTALLATION & OPERATION HANDBOOK. P052971K Rev. 8 7/04 COMPONENT

DELI MODELS: OSI, OWSI, OSIO & OWSIO INSTALLATION & OPERATION HANDBOOK. P052971K Rev. 8 7/04 COMPONENT DELI C A S E S MODELS: OSI, OWSI, OSIO & OWSIO INSTALLATION & OPERATION HANDBOOK COMPONENT P05971K Rev. 8 7/04 Welcome to the ORIGIN display case family. We re very pleased you joined us. This installation

More information

GCG-26c. Instruction Manual. G-Series Cooler

GCG-26c. Instruction Manual. G-Series Cooler G-Series Cooler UPRIGHT COOLER Manual is for the following models: GCG-26-C14N7 GCG-26-C14NG GCG-26-C14NI GCG-26-C14NM GCG-26-C14NJ GCG-26 G-26-C14N7 G-26-C14NG G-26-C14NI G-26-C14NM G-26-C14NJ G-26 Instruction

More information

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS INSTALLATION and OPERATION INSTRUCTIONS SINGLE DOOR freezer MODEL NOS. FN FS Finished Stainless Steel Top Non-Finished Top FS FN IMPORTANT INFORMATION This manual has been prepared to assist you in the

More information

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill

More information

COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL

COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL Model No.: TGM-50RS TGM-72RS FEATURE CHART Before operating this unit, please read these instructions completely. HOW TO INSTALL In good ventilation. Place the

More information

Wax Base Heater & Dispenser

Wax Base Heater & Dispenser Wax Base Heater & Dispenser Service Manual Models: IDWB2/0900, IDWB2/0775, IDWB3/0900, IDWB3/0775, IDWB4/0900, IDWB4/0775 Introduction............................................................................

More information

Cincinnati, OH USA

Cincinnati, OH USA Heated Portion Pack Display Case Instruction Manual Model #5580BV1, Model #5588 and Model #5581 Part No. 74797 Revised April 2000 Cincinnati, OH 45241-4807 USA e-mail: goldme19@eos.net www.gmpopcorn.com

More information

Manual is for the following models: G-26 GCG-26 GCG-26-C31N* G-26-C31N* GCG-26-C231N* GCG-26-CA31N* *G,I,M,7,J plug. Instruction Manual.

Manual is for the following models: G-26 GCG-26 GCG-26-C31N* G-26-C31N* GCG-26-C231N* GCG-26-CA31N* *G,I,M,7,J plug. Instruction Manual. G-Series Cooler G-26c/GCG-26c UPRIGHT COOLER Manual is for the following models: G-26 GCG-26 GCG-26-C31N* G-26-C31N* GCG-26-C231N* GCG-26-CA31N* *G,I,M,7,J plug Instruction Manual Manual is for the following

More information

INSTALLATION and OPERATING. INSTRUCTIONS for. SMZP26 Series. elf-contained Freezers

INSTALLATION and OPERATING. INSTRUCTIONS for. SMZP26 Series. elf-contained Freezers S elf-contained Freezers INSTALLATION and OPERATING INSTRUCTIONS for Series ZERO ZONE Zero Zone, Inc. 110 N. Oakridge Dr. North Prairie, WI 53153-9792 1-800-247-4496 FAX: 1-414-392-6450 www.zero-zone.com

More information

Bottle Coolers. Manual for installation, use and Maintenance

Bottle Coolers. Manual for installation, use and Maintenance Bottle Coolers. Manual for installation, use and Maintenance 1 RECEIVING AND INSPECTING Upon receiving your new Fagor Equip, check the package and the machine for any damages that may have occurred during

More information

INSTALLATION AND OPERATION INSTRUCTIONS STANDARD BACK BAR COOLERS, SELF CONTAINED MODEL NOS.

INSTALLATION AND OPERATION INSTRUCTIONS STANDARD BACK BAR COOLERS, SELF CONTAINED MODEL NOS. INSTALLATION AND OPERATION INSTRUCTIONS STANDARD BACK BAR COOLERS, SELF CONTAINED MODEL NOS. CS Series IMPORTANT INFORMATION Fill out the enclosed warranty card and mail to the Perlick Corporation to register

More information

INSTALLATION AND SERVICE MANUAL REMOTE TYPE DISPLAY CASE

INSTALLATION AND SERVICE MANUAL REMOTE TYPE DISPLAY CASE Multi-Deck Self Service Fresh Meat Merchandiser Multi-Deck Self Service Fresh Meat Merchandiser FPW-EXA085 FPW-EXA085 FPW-EXA025 FPW-EXA025 INSTALLATION AND SERVICE MANUAL REMOTE TYPE DISPLAY CASE TABLE

More information

COUNTER TOP REFRIGERATION MODEL SERIES HUBM-2RB/HUBM-2FB/HUBM-3.5RB/HUBM-3.5FB HUBM-2R/HUBM-2F/HUBM-3.5R/HUBM-3.5F

COUNTER TOP REFRIGERATION MODEL SERIES HUBM-2RB/HUBM-2FB/HUBM-3.5RB/HUBM-3.5FB HUBM-2R/HUBM-2F/HUBM-3.5R/HUBM-3.5F HUBM-2R HUBM-2F HUBM-3.5R HUBM-3.5F HUBM-2RB HUBM-2FB HUBM-3.5RB HUBM-3.5FB Please read this manual completely before attempting to install or operate this equipment. Notify carrier of damage! Inspect

More information

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual This owner s manual provides instructions on safe installation use, and troubleshooting assistance. Please read it carefully and save it for reference

More information

CHEST FREEZER INSTRUCTION MANUAL. Model No.: EWCF5WBX EWCF7WBX

CHEST FREEZER INSTRUCTION MANUAL. Model No.: EWCF5WBX EWCF7WBX CHEST FREEZER INSTRUCTION MANUAL Model No.: EWCF5WBX EWCF7WBX To ensure proper use of this appliance and your safety, please read the following instructions completely before operating this appliance.

More information

BOTTOM MOUNT REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

BOTTOM MOUNT REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions BOTTOM MOUNT REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the Bill of Lading

More information

Instruction Manual. Window AC 12000BTU. Energy- Saving Mode. Wards.com MODEL: 12000BTU Item No.: V~, 60Hz, 1060W

Instruction Manual. Window AC 12000BTU. Energy- Saving Mode. Wards.com MODEL: 12000BTU Item No.: V~, 60Hz, 1060W Energy- Saving Mode Window AC 12000BTU MODEL: 12000BTU 11.2 Montgomery Ward Customer Service 1112 7th Avenue, Monroe, WI 53566 8:00 am to Midnight, Monday through Friday Wards.com 1 888 557 3848 Instruction

More information

SERIES NAV S Display Merchandisers

SERIES NAV S Display Merchandisers SERIES NAV S Display Merchandisers Medium Temperature Merchandisers PLEASE READ THIS MANUAL BEFORE USING THE PRODUCT Installation & Operation Manual P/N 2400204D NAV S Series May 2006 HUSSMANN CORPORATION

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl50uq, BFL60UQ, BFL70, BFL85 Item Stock Number(s): BFL50UQ, BFL60UQ, BFL70, BFL85 IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY

More information

INSTRUCTIONS! DO NOT DISCARD!

INSTRUCTIONS! DO NOT DISCARD! INSTRUCTIONS! DO NOT DISCARD! CAUTION! Do NOT install where injury might occur due to Moving parts, Sharp corners, Hot surfaces or electrical components d N0417 Page 1 of 10 INSTALLATION INSTRUCTIONS CAUTION

More information

BACK BAR REFRIGERATION Installation, Operation and Maintenance Instructions

BACK BAR REFRIGERATION Installation, Operation and Maintenance Instructions BACK BAR REFRIGERATION Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the Bill of Lading to ensure all crates

More information

SLIDER CASEMENT AIR CONDITIONER

SLIDER CASEMENT AIR CONDITIONER OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS SLIDER CASEMENT AIR CONDITIONER ROTARY CONTROL P/N 309000854 (11/03) ROOM AIR CONDITIONER WARRANTY Your product is protected by this warranty Your appliance

More information

Cincinnati, OH USA

Cincinnati, OH USA Heated Portion Pack Display Case Instruction Manual Model #5580BV1, Model #5588 and Model #5581 Part No. 74797 Revised April 2000 Cincinnati, OH 45241-4807 USA e-mail: goldme19@eos.net www.gmpopcorn.com

More information

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

IMPORTANT INSTRUCTIONS - OPERATING MANUAL IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: AK80LSL, AK100LSL Exhaust Fan READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.

More information

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- 8610 Production Avenue San Diego, California 92121 (858) 566-7465 Fax (858) 566-1943 WWW.BREEZAIRE.COM WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- Thank you for choosing a BREEZAIRE cooling

More information

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS INSTALLATION and OPERATION INSTRUCTIONS Single Door cooler series MODEL NOS. CS32SB CS32SG CS32SS CS32ST IMPORTANT INFORMATION To register your product, visit our web site at (www.perlick.com). Click on

More information

e Heater/Exhaust Fan/Light User s Guide

e Heater/Exhaust Fan/Light User s Guide e Heater/Exhaust Fan/Light User s Guide abflh70l, BFLH85L Item Stock Number(s): BFLH70L, BFLH85L IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING

More information

Ui REFRIGERATOR SPEC SHEET

Ui REFRIGERATOR SPEC SHEET Ui REFRIGERATOR SPEC SHEET ISOMETRIC VIEW 19 7/8 20 1/2 32 3/4 FRONT VIEW NOTES: 1. CUTOUT DIMENSIONS: 20 1/2"W X 33"L X 20 3/4"D 2. CUTOUT DIMENSIONS ARE FOR REFRIGERATOR ONLY. REFER TO STAINLESS STEEL

More information

AIR CONDITIONER ELECTRONIC CONTROL

AIR CONDITIONER ELECTRONIC CONTROL READ AND SAVE THESE INSTRUCTIONS AIR CONDITIONER ELECTRONIC CONTROL ROOM AIR CONDITIONER WARRANTY Your product is protected by this warranty Your appliance is warranted by Electrolux. Electrolux has authorized

More information

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4-5. Replacement Element Installation 5. Replacement Parts 5-6

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4-5. Replacement Element Installation 5. Replacement Parts 5-6 TABLE OF CONTENTS Warnings 2 Installation Instructions 3 Wiring Instructions 3 Mounting Instructions 4-5 Replacement Element Installation 5 Replacement Parts 5-6 Heater Coverage Areas 6 General Notes 6

More information

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide Installation Manual and Owner s Guide IAQ Series Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application PCOB-09012-0--A - 9" PCO BULB PCOB-14024-0--A - 14" PCO BULB 67202220344 Revised 07-12

More information

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International 11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions Model No. PE4-11R-03 2006 Soleus Air International Thank you for choosing a Soleus Air Portable Air Conditioner.

More information

User Manual / Installation Instructions

User Manual / Installation Instructions User Manual / Installation Instructions Outdoor Refrigerator MODEL: L24REF Lynx Professional Grills 5895 Rickenbacker Rd., Commerce, CA 90040 Service: (888) 289-5969 Tel: (323) 838-1770 Fax: (323) 838-1778

More information

HD-26, HD-36, HD-48 Heated Displays

HD-26, HD-36, HD-48 Heated Displays HD-26, HD-36, HD-48 Heated Displays This manual contains important information regarding your Admiral Craft unit. Please read this manual thoroughly prior to equipment set-up, operation and maintenance.

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl125rok Item Stock Number(s): BFL125ROK IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL,

More information

Ice Cream Freezer Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

Ice Cream Freezer Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! Turbo Air Speed up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Ice Cream Freezer Installation and Operation Manual Please read this manual completely before

More information

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the Bill of Lading to ensure all crates

More information

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call Service Manual Design Basics Hot Food Tables Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF For Service Information, Call 800-544-3057 Please provide the following information: - Model number - Serial

More information

INSTALLATION USE & CARE MANUAL ALL WEATHER W-SERIES AND WD-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

INSTALLATION USE & CARE MANUAL ALL WEATHER W-SERIES AND WD-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL ALL WEATHER W-SERIES AND WD-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS Warnings 2 Installation Instructions 3 Wiring Instructions 3 Mounting Instructions

More information

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5 Introduction The Scotsman Compact Refrigerator is a unique product, capable of being built into a cabinet because of its front vented, forced-air cooling system. It s also designed to be a companion to