1 Enclave Printer Enclave ENCLAVE N-CLASS
2
3 This manual s objective is to familiarize clients with the operating procedure for the GDP range of Autoclaves 1. Enclave N-Class (12/16/22 Litres) 2. Enclave B-Class (12/16/22 Litres) 3. Encalve Elite It offers to the operator information that will allow him/her to obtain the best results in any step of the Sterilization. Following the given procedure will extend the eqiupment s lifespan Most of the biosafety information included in this manual was based on publication from reliable proferssors, providing you directives for complete safety and correct sterilization. Ant sort of damage due to negligence, misuse, non-authorized repairs, physical damage etc. will void your product s warranty. For reference, A warranty certificate is attached at the end of the manual. Please fill that form and return it to the company address. GDP Enclave comes in two major autoclave classes 1. Enclave B-Class with 6 Vacuum Cycles and Dry Cycle. 2. Enclave N-Class with 3 Thermal Purging Cycles and Dry Cycle.
4
5 Autoclaves work under pressure and high temperature and must be handled by skilled and trained operators who are well educated on how to properly operate the autoclave. It is Fundamental that each operator reads the complete instructions manual prior to the us of ENCLAVE Autoclaves.
6 The autoclave must be installed on a flat surface. The drainage point should be within 1.5 meter of the autoclave, or a bucket for collecting water should be placed near it. It is recommended to leave some space around the autoclave for ease of handling. Check the identification affixed on the back of the autoclave (Pic. 01) Make sure that the electric voltage is correct. Warning! Not using the correct voltage and amperage can cause serious damage or malfunction to your Autoclave. Dibya Industries India, It s Distributors or Dealers will not be liable for damage caused by improper and/or inadequate voltage/amperage.
7 Safety Release Valve (MCB) 1. DRAINAGE INSTALLATION The Enclave Comes with a drainage pipe and a connector elbow nozzle for installation. Connect the nozzle at the External Exit firmly and place the end of the pipe into a sink. Warning! The drain pipe should not be dipped in any stagnant water,nor should it have any form of bending. Make sure that the drainage pipe is installed without bends and out of stagnant water. The extremity of the tubing must be free of any obstruction. Drainage Pipe Drain Connector
8
9 Enclave 12/16/22 Liter autoclave provide the following safety mechanisms:
10 4. MCB (Circuit Breaker) - Provides safety from fluctuating voltage. 5.RTD - Internal Sensor of the Autoclave 6.Pressure Release Valve - Manual Pressure normalizing system provided for emergency and power cutoffs. 16L 22L 250 ML 350 ML 500 ML
11 d. Press the Start and the autoclave cycle initiates. Now the whole operation is completely automatic and requires no supervision. CYCLE-INFORMATION For ENCLAVE B-CLASS Autoclaves :- Switch on the Enclave and Power ON the MCB, you will get a message as given in the picture. Put your instruments inside and close the door. Press Start button. A) Pre-Heating Cycle will start to create pressure inside the chamber. The pressure gradually increases along with the temperature. B) 1st Thermal Purging Cycle is started at 95 C to purge out the air and steam with great force, to forcefully throw out air. Cycle Time : 60secs. C) 2nd Thermal Purging Cycle is started at 110 C to further push out air inside the chamber with the steam. Sudden release of pressure purges out the remaining air left. Cycle Time : 90secs. C) 3rd Thermal Purging Cycle is started at 115 C to saturate steam inside the instruments. Any air pockets left inside are completely erased. At this point only steam remains inside the chamber. Cycle Time : 90secs. D) Heating Cycle initiates with dynamic real time control of heater power to perfectly manage the temperature inside the chamber. E) At 121C the Sterilization Cycle starts and the heater power is constantly regulated to accurately maintain the parameters of Sterilization. The power consumption is extremely less compared to conventional methods. Cycle Time : 16Mins. Note: If you don't need Dry Cycle, then you can press CANCEL here to take out the sterilized instruments.
12 F) At the end of Sterilization, a buzzer sound is made to indicate the end of sterilization cycle. All the water and steam, is purged out through the drainage. A message for Sterilization Completion will be displayed. At this point, you can CANCEL the cycle if the Dry-Cycle is not required. Buzzer Time : 30Secs. G) Dry-Cycle Preheat starts and the heater starts heating the drum to 140 C. Dynamic power delivery is given to the heater, which leads to a much lower power consumption and prolonged heater life. H) Dry-Cycle starts at 120 C to completely dry the sterilized instruments. Temperature in the chamber and time will be displayed. Cycle Time : 16Mins. I) End of Cycle is displayed on the LCD. Now the instruments are now completely dry and sterilized. They are being kept in a sealed chamber and as long as they are in the chamber they are sterilized. PRESS CANCEL and wait for 60Secs to normalize the chamber pressure. Open the door and remove the trays through the tray holder. Switch off the Enclave Autoclave. NOTE!: The Autoclave should be turned OFF if not in use. Total Cycle-Time ~ 1 hour 5 mins. NOTE: Wait for atleast 30Mins for consecutive cycle in Enclave.
13
14 pressure. not indicate Negative Pressure generated during cooling of the Enclave. The Manometer does not indicate negative pressure. Power Cutoff /Faulty Valve and there is pressure/vacuum in the chamber. (60Secs) Remove the hose at the drainage exit from the back. Check the drainage pipe for any bends, obstructions. Check wether the pipe is in any stagnant water. Check if the pipe/hose are blocked. Clean the pipe and hose, reattach and check again. The pressure release valve at the back is provided for such an emergency. Pull the ring at the back for 30Secs to normalize the pressure inside the chamber, Then you can open the door. THE ENCLAVE T
15 plug at electric outlet Tripped MCB Power On the MCB provided at the back of Enclave
16 Regd Office: 13 Shrestha Vihar, Vikas Marg Extn, Delhi Manufacturing Unit : A-2/34, Site IV, Industrial Area,Sahibabad , Ghaziabad,U.P. Mob : , , gdpdental@gmail.com
17 Enclave - 12NP/ 12N/ 16NP/ 16N/ 22NP/ 22N Regd Office: 13 Shrestha Vihar, Vikas Marg Extn, Delhi Manufacturing Unit : A-2/34, Site IV, Industrial Area, Sahibabad , Ghaziabad, U.P. Mob : , , web : www. gdpdentalproducts.com /www dibyaindustries.com -gdpdental@gmail.com
18 Enclave - 12NP/ 12N/ 16NP/ 16N/ 22NP/ 22N Regd Office: 13 Shrestha Vihar, Vikas Marg Extn, Delhi Manufacturing Unit : A-2/34, Site IV, Industrial Area, Sahibabad , Ghaziabad, U.P. Mob : , , web : www. gdpdentalproducts.com /www dibyaindustries.com -gdpdental@gmail.com
APPENDIX 4. Thank you for choosing the Biomega BioClave steam sterilizer. HYDRAULIC DRAWING
Thank you for choosing the Biomega BioClave steam sterilizer. Your steam sterilizer has been CE certified and designed with durability, reliability, and safety in mind. It is your responsibility to install
More informationSX-300 SX-500 SX-700
OPERATOR'S MANUAL AUTOCLAVE SX-300 SX-500 SX-700 Before starting operation, read this manual thoroughly for a complete understanding of the autoclave and its correct operation. Carefully store this operation
More informationOperations Manual. Part Number: For Research Use Only
Operations Manual Part Number: 470230-598 For Research Use Only Ph: 1-800-962-2660 - Web: www.wardsci.com Thank you for choosing our Bench top sterilizers. Prior to operating this instrument, please read
More informationRELIABLE. The Midmark M9 and M11 UltraClave Automatic Sterilizers - make sterilization reliable and efficient.
Next M 9 & M 1 1 U LT R A C L AV E RELIABLE The Midmark and UltraClave Automatic Sterilizers - make sterilization reliable and efficient. Today, more than ever, you need reliable and easy to use products
More informationInstalling the Vacuklav 40-B / 44-B
Installing the Vacuklav 0-B / -B Please read the operating manuals of the autoclave and of the water purification unit first! The Vacuklav 0-B / -B are autoclaves with fractionating pulsed vacuum procedure.
More informationIMAGE PRESS & IMAGE PORCELAIN OVEN. 120V, 50/60 Hz Models and 230V, 50/60 Hz Models. Operator s Manual
IMAGE PRESS & IMAGE PORCELAIN OVEN 120V, 50/60 Hz Models and 230V, 50/60 Hz Models Operator s Manual TABLE OF CONTENTS Congratulations.. 3 Warranty. 3 Safety Notice. 4 Electrical Safety Notes.. 5 Knowledge
More informationSteam Fundamentals. (in heating & processing applications)
Steam Fundamentals (in heating & processing applications) Introduction Common Heat Energy conveyers: Thermal Oil Hot water Steam Electrical Electric Heaters Electrodes (High Current) Steam Fundamentals
More informationAUTOMATIC STERILIZERS
AUTOMATIC STERILIZERS MIDMARK DELIVERS WHAT YOU NEED IN INSTRUMENT PROCESSING. Our full line of sterilizers are designed to address all of your critical cleaning needs. In fact, we re sure you ll find
More informationlaboratory & sterilization technology
laboratory & sterilization technology NC 23B - NC 23S/32S BENCH TOP STEAM STERILIZERS Small steam sterilizers are widely used for the sterilization of the products used for medical purposes, e.g in general
More informationUpholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98)
32506 Upholstery and Drapery Cleaner Model No.: 32506 3 gal Extractor Operator and Parts Manual KLEENRITE 1122 MAPLE STREET MADERA CA 93637 U.S.A. FAX: 1-559-673-5725 CUSTOMER SERVICE: 1-800-241-4865 MNL32506
More informationAUTOMATIC MODULAR ICE FLAKER
AUTOMATIC MODULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24479 rev. 08 It is strictly forbidden to reproduce this instruction manual or any part thereof. 1 5 3 4 Mod. N. V. W 2 2 M8 18 8 18 M8 M8 3 ~ 200
More informationAUTOMATIC MODULAR ICE-CUBE MAKER
AUTOMATIC MODULAR ICE-CUBE MAKER INSTRUCTIONS AND WARNINGS 24851 ed. 06-2012 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on having
More informationInstruction Manual. Juice Extractor. Model: ESI Dezembro/2008
Instruction Manual Juice Extractor 36202.6- Dezembro/2008 Model: ESI 5. PROBLEMS ANALYSIS and SOLUTIONS 5. 1 Problems, Causes and Solutions The Juice Extractor Mod. ESI were designed to operate with the
More informationAUTOMATIC MODULAR ICE-CUBE MAKER WITH VERTICAL EVAPORATOR SYSTEM
AUTOMATIC MODULAR ICE-CUBE MAKER WITH VERTICAL EVAPORATOR SYSTEM INSTRUCTIONS AND WARNINGS 24481 ed. 11-2007 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear
More informationFINO JETSTEAM PRO 52072
Original FINO Germany FINO JETSTEAM PRO 52072 Dampfstrahlgerät Steam Cleaner Appareil à jet de vapeur Vaporizadora Vaporizzatrice Stoomstraalapparaat Parní čistička Ångstråleapparat Parownica Gőzsugár
More informationAUTOCLAVE STEAM STERILIZERS (BENCH TOP)
AUTOCLAVE STEAM STERILIZERS (BENCH TOP) Image: HS-1606VD Hanshin Bench Top Steam Sterilizer Small and easy to operate Three preset sterilization cycles Adjustable cycle presets Rapid heat up times Option
More informationPUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650
USER GUIDE PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650 AB0039 FOR RESIDENTIAL USE ONLY!! BROAN-NUTONE LLC; HARTFORD, WISCONSIN WWW.NUTONE.COM 1-888-336-3948 REGISTER YOUR PRODUCT ONLINE
More informationVANTAGE. Installation Manual. Release Date: April 16, 2003 Publication Number: INS Revision Date: January 22, 2015 Revision: E
VANTAGE Installation Manual Release Date: April 16, 2003 Publication Number: 3120031005INS Revision Date: January 22, 2015 Revision: E Visit the Cornelius web site at www.cornelius.com for all your Literature
More informationInstallation & Operating Guide
5-036 HOT WATER TANK Installation & Operating Guide Read all instructions thoroughly. Keep this guide for future reference. Proof of purchase is required for Warranty. Staple receipt or proof of purchase
More informationPortable Air Conditioner
AC-12200E AC-12200H Portable Air Conditioner OWNER S MANUAL v1.0 Read and save these instructions. 2 A Name You Can Trust Trust should be earned and we will earn yours. Customer happiness is the focus
More informationBluestone Industrial & Trading Limited
VA-SA35 600*410*1030 77 1. Full stainless steel structure 2. Automatic control in processes of filling water, heating, sterilization, steam e*haust and dryness. 3. Door safety lock system 4. Built-in water
More informationAUTOMATIC GRANULAR ICE FLAKER
AUTOMATIC GRANULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24480 rev. 01 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on choosing a
More informationPortable Air Conditioner AP8000W. Owner s Manual
Portable Air Conditioner AP8000W Owner s Manual For more information on other great EdgeStar products on the web, go to https://www.edgestar.com To use the EdgeStar self-diagnostic tool, go to https://support.edgestar.com
More informationB+N 18/23L LED. Ritter CleanTec with LED Display BB 18 + BB 23. Sterilizable Products:
Ritter CleanTec with LED Display BB 18 + BB 23 The CleanTec is available with an 18 to 23 liter chamber size and is a stand-alone autoclave with built-in water storage tank. It works with a fractionated
More informationInstruction Cum User Manual For EUROLITE
An ISO 9001:2008, 13485: 2012 Certified Company Instruction Cum User Manual Bacterial Filter Vacuum Gauge Connector for Patient use Float Valve Hi/Low Switch On/Off Switch Vacuum Control Knob 1 Ltr PC
More informationLGR Dehumidifier Owner s Manual
LGR Dehumidifier Owner s Manual 115v Model: DH 075 ORG Please read this owner s manual before operating and keep safe for future reference GENERAL INFORMATION Thank you for choosing our LGR Dehumidifier
More informationPOWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings
POWDER GUIDE From ASIAN PAINTS (I) LTD Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings Section A : Powder Application Problems Trouble Possible Causes Solutions 1. Poor charging
More informationINSTALLATION GUIDE Little Butler Hot Water Dispensing Faucets and Drinking Water Dispensing Faucets
INSTALLATION GUIDE Little Butler Hot Water Dispensing Faucets and Drinking Water Dispensing Faucets DW000 / LB00 Series LB00 Series DW00 / LB00 Series LB00 Series DW7000 / LB700 Series LB700 Series DW8000
More informationVertical Laboratory Autoclave A series:
Vertical Laboratory Autoclave A series: of Labtron Vertical Laboratory Autoclave LVA-A series is a top loading sterilizer which provides safe, Made up of SUS304 stainless steel Dual scale numerical pressure
More informationUser Guide. For THE SWIMSUIT DRYER. Swimsuit Dryer manual Final. Copyright 2014 Page of 20
User Guide For THE SWIMSUIT DRYER. Swimsuit Dryer manual Final Copyright 2014 Page of 20 1 Table of Contents 1 LOCATION & INFORMATION DIAGRAMS... 4 2 PURPOSE... 6 2.1 PROPER USAGE AND LIABILITY... 6 2.2
More informationTH100 Three in One Instant Hot Water Tap
TH100 Three in One Instant Hot Water Tap Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu
More informationBlueHeat AirTop 2000 Heater
BlueHeat AirTop 000 Heater Air Heater Installation Manual Ford E-Series 6.0L Diesel Beginning Model Year: 006 Special instructions for these models Part locations may differ slightly dependent on the vehicle
More informationGarment Steamer Model SC620
OWNER S MANUAL Garment Steamer Model SC620 For information or assistance: EURO-PRO Corporation 178 West Service Rd. Champlain, NY 12919 1-800-798-7398 www.euro-pro.com IMPORTANT SAFETY INSTRUCTIONS When
More informationProfessional sterilization systems
Professional sterilization systems Professional sterilization systems Newmed was created to satisfy the needs of customers who demand safety, reliability and simplicity all in one sterilization instrument.
More informationAC-12200E Portable Air Conditioner
AC-12200E Portable Air Conditioner OWNERS MANUAL Read and save these instructions. A Name You Can Trust Trust has to be earned and we will earn yours. Customer happiness is the focus of our business. 2
More informationSpecifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1
Specifications Rated voltage (V) AC 110-120V or 220-240V / 50-60Hz Vacuum motor power consumption(w/hp) 1200 / 1.6 Exhaust water pump power consumption(w/hp 800 / 1.1 Exhaust water pump flow (GPH/LPH)
More informationInstruction Manual. Automatic fuel oil de-aerator SMART-FLO 3/K B100 COMPATIBLE
Sid Harvey s 605 Locust Street Garden City, NY 11530 Instruction Manual Automatic fuel oil de-aerator SMART-FLO 3/K Read manual before use! Observe all safety information! Keep manual for future use! 05.2015
More informationAUTOMATIC ICE-CUBE MAKER
AUTOMATIC ICE-CUBE MAKER INSTRUCTIONS AND WARNINGS 24478 ed. 11-2007 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on having chosen
More informationPRE AND POST VACUUM CLASS B AUTOCLAVE
PRODUCT CATALOG PRE AND POST VACUUM CLASS B AUTOCLAVE www.biolabscientific.com PRE AND POST VACUUM CLASS B AUTOCLAVE Reliable and robust class B autoclaves intended to deliver highest quality of sterilization.
More informationMODULAR AUTOMATIC GRANULAR ICE FLAKER
MODULAR AUTOMATIC GRANULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24479 rev. 03 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on having
More informationKrishna engineering corporation
Krishna engineering corporation ABOUT US: Started in the year 2000, we at Krishna Engineering Corporation are engaged in manufacturing and exporting a wide range of Sterilizer s. Moreover, we also hold
More informationEVAPORATIVE COOLER W
EVAPORATIVE COOLER 972-1003-W USER MANUAL INTRODUCTION READ AND SAVE THESE INSTRUTIONS! 1 Thanks for your support and choice of our unique tower fan, in order to help you use the product more conveniently,
More informationTabletop 2340 EA-D Class S Autoclave 19 Litres
Tabletop 2340 EA-D Class S Autoclave 19 Litres Save time and improve efficiency in your clinic. Sterilisation in three simple steps: 1. Select the right program 2. Close the door 3. Press the Start Button
More informationUser and Installation Instructions. Electric Auto-Fill Water Boilers EB3F, EB4F, EB6F, EB6TF IS339 ECN3539
User and Installation Instructions Electric Auto-Fill Water Boilers EB3F, EB4F, EB6F, EB6TF IS339 ECN3539 Dear Customer Thank you for purchasing this Lincat product. With correct use and careful maintenance
More informationInstruction Manual. Bottle Cooler. Models HBC-50 (-S) HBC-65 (-S) HBC-80 (-S) HBC-95 (-S) hoshizakiamerica.com. Issued: Revised:
Instruction Manual Bottle Cooler Models HBC-50 (-S) HBC-65 (-S) HBC-80 (-S) HBC-95 (-S) hoshizakiamerica.com Issued: 06-11-2018 Revised: WARNING Only qualified service technicians should install and service
More informationMoisture inside the drum is due to final testing.
Safety instructions Scope of delivery depending on model Moisture inside the drum is due to final testing. Removing the transport braces Water connection depending on model The washing machine is heavy
More informationPORTABLE AIR CONDITIONER (LOCAL)
EN PORTABLE AIR CONDITIONER (LOCAL) OPERATING INSTRUCTIONS Read the instructions carefully before operating the appliance or carrying out maintenance work. Observe all the safety instructions; failure
More informationMULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H056
MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL Call 888.896.8786 Model #: H056 IMPORTANT SAFE T SAVE THESE INSTRUCTIONS When using an electrical appliance, basic safety precautions should always be observed,
More informationPriorclave Tactrol Controller Warning Lights and Fault Codes
Priorclave Tactrol Controller Warning Lights and Fault Codes Warning Lights The control panel has a series of hidden until active warning indicators that appear in the black bar beneath the Temperature
More informationInstallation and Operation Guide
Hot Water on Demand Installation and Operation Guide Thermostatic Series 18kW, 21kW, 24kW 118 º F www.atmorusa.com Table of Contents Description Page Safety Guidelines...2 Technical Information...3 Plumbing...
More informationInstallation & Operators Manual
Installation & Operators Manual Eco, Hydro and Duo under counter range Part number 902.0001 Revison B Installation and Operation instructions For Classeq under counter range of glass and dishwashers. Section
More informationAUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS
AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS Dear Customer, Congratulations on having chosen a quality product which will certainly fully meet your expectations. Thank you for having purchased
More informationViking Installation Guide
Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at
More informationVacuum Cleaner User's manual
User's manual SVC 52BK / SVC 52GR / SVC 52WH Before first use, please read all instructions contained in this user's manual carefully, even if you are already familiar with using similar products. Only
More informationVertical Autoclave Sterilizer Catalog. Picture Description Model No. Volume
1. Full stainless steel structure 2. Automatic control in processes of filling water, heating, sterilization, steam e*haust and dryness. 3. Door safety lock system 4. Built-in water tank 5. Preheating
More informationUSER MANUAL. Version: 1.0. ROBE Show Lighting s.r.o. Czech Republic
USER MANUAL Version: 1.0 ROBE Show Lighting s.r.o. Czech Republic www.robe.cz Table of contents 1.Introduction 4 2.Cautions 4 3. Unpacking & Inspection 5 4. Setup 5 5. Operation 5 5.1.Control Module Operation
More informationFDT11 FDT15 FDT18. DUCTED TYPE SPLIT SYSTEMS (3 Phase, Fixed Speed)
OPERA TION & I NSTALLAT I O N FDT11 FDT15 FDT18 MANUAL DUCTED TYPE SPLIT SYSTEMS (3 Phase, Fixed Speed) Read this operating & installation instruction carefully and keep it for future reference DUCTED
More informationPORTABLE AIR CONDITIONER OWNER S MANUAL
PORTABLE AIR CONDITIONER OWNER S MANUAL ASSEMBLY AND OPERATING INSTRUCTIONS MODELS: JHS-A018-10KR SKU#: 130004 JHS-A018-12KRH SKU#: 130005 WARNING: Read and follow all warnings and instructions in this
More information1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm
Safety instructions The washing machine is heavy - take care when lifting. Caution: frozen hoses may rip/burst. Do not install the washing machine in areas exposed to frost or outdoors. The washing machine
More informationEZ9Plus & EZ11Plus Instructions on: Operating
EZ9Plus & EZ11Plus Instructions on: Operating Step 1 Turn the unit on by setting the rocker switch mounted on the right side of the front panel to the On position. NOTE: The EZ11Plus has an automatic pre-heating
More informationUser Manual. Reflow Batch Oven Model: X-REFLOW305
MBR ELECTRONICS SOLDER TECHNOLOGY JONASTRASSE 8 CH-8636 WALD SWITZERLAND Internet:www.mbr.ch E-Mail: info@mbr.ch Tel: +41(0)55 246 2400 Fax: +41(0)55 246 2418 schafft Vorsprung User Manual Reflow Batch
More informationM9 M /M3 11/ Automatic Sterilizers
M9 M /M3 11/ Automatic Sterilizers What do you want in a sterilizer? n Patented, automatic-opening door for fast instrument drying n Fast and easy use for efficient instrument processing n Reliable and
More informationN-Wissen GmbH. Top Loading Autoclaves (95, 120, 135 L) Available top loading models: The Top Loading Autoclave range features:
Top Loading Autoclaves (95, 120, 135 L) The Top Loading Autoclave range features: A choice of 63, 95, 120 and 135 litres models A fully programmable 5,7 Touch Screen Colour Controller Timed/Pulsed Free
More informationPortable Air Conditioner AP12000S-1. Owner s Manual
Portable Air Conditioner AP12000S-1 Owner s Manual For more information on other great EdgeStar products on the web, go to https://www.edgestar.com To use the EdgeStar self-diagnostic tool, go to https://support.edgestar.com
More informationMODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER
USER S INFORMATION MANUAL MODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER NOTE TO INSTALLER: This manual must be left with the equipment user. WELCOME TO EFFICIENT HOME COOLING COMFORT Congratulations
More informationwww.indesit.com/register GB Contents Safety instructions, 3 Safeguarding the environment, 5 Setting up your oven, 6 Operation instruction, 7 Troubleshooting, 11 Installation instruction, 12 2 SAFETY INSTRUCTIONS
More informationPORTABLE AIR CONDITIONER (LOCAL)
EN PORTABLE AIR CONDITIONER (LOCAL) OPERATING INSTRUCTIONS Read the instructions carefully before operating the appliance or carrying out maintenance work. Observe all the safety instructions; failure
More informationINSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250
INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250 Release Date: March 24, 2004 Publication Number: 92181INS Revision Date: April 07, 2014 Revision: G Visit the Cornelius web site at www.cornelius.com
More informationK 2.97 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS
K 2.97 M High Pressure Washer Operator Manual Overview... 2 Important Precautions... 3-4 Assembly Instructions... 4 Operating Instructions... 5 GFCI Instructions... 6 Using the Accessories... 6 Working
More informationAC Portable Air Conditioner AC-14100E, AC-14100H OWNERS MANUAL. Read and save these instructions.
AC-14100 Portable Air Conditioner AC-14100E, AC-14100H OWNERS MANUAL Read and save these instructions. 2 A Name You Can Trust Trust has to be earned and we will earn yours. Customer happiness is the focus
More informationDEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference.
OWNER S MANUAL DEHUMIDIFIER ESPAÑOL FRANÇAIS Read this manual carefully before operating the appliance and retain it for future reference. Model : UD701KOG1 P/NO : MFL68026017 www.lg.com TABLE OF CONTENTS
More informationInstallation and Operation Guide
Hot Water on Demand Installation and Operation Guide Thermo-Pro Thermostatic Series 18kW, 21kW, 24kW, 27kW 118 º F www.atmorusa.com Table of Contents Description Page Safety Guidelines...2 Technical Information...3
More informationInstallation and Operation Guide
Hot Water on Demand Installation and Operation Guide Thermo Boost Instant Water Heater Digital electric tankless instant water heater provides endless supply of hot water while significantly conserving
More informationChapter 7 Checks and Maintenance
Chapter 7 Checks and Maintenance This chapter explains equipment checks and maintenance. To keep the chamber in good working condition, perform checks and maintenance periodically. 97 7.1 Check and Maintenance
More informationTheory of Operation: M9/D & M11/D
: M9/D & M11/D NOTE This document applies to the following models: M9/D (-020 thru -022) (-033 & -034) M11/D (-020 thru -022) (-033 & -034) Mode / System Page Power Up Mode... 2 Select Cycle Mode... 4
More informationINSTALLATION GUIDE Little Butler Hot Water Dispensing Faucets and Drinking Water Dispensing Faucets
INSTALLATION GUIDE Little Butler Hot Water Dispensing Faucets and Drinking Water Dispensing Faucets DW000 / LB00 Series LB00 Series DW00 / LB00 Series LB00 Series DW7000 / LB700 Series LB700 Series DW8000
More informationLABOKLAV. Autoclaves Made in Germany
LABOKLAV Autoclaves Made in Germany 2 LABOKLAV STEAM STERILIZERS Steam sterilization is the sterilization method with the widest range of applications efficient, safe, reproducible and environmentally
More informationVacuum Cleaner User's manual
Vacuum Cleaner User's manual EN Before first use, please read all instructions contained in this user's manual carefully, even if you are already familiar with using similar products. Only use this product
More informationMODEL 7000 SUCTION UNIT
MODEL 7000 SUCTION UNIT OPERATOR S MANUAL Caution Federal law restricts this device to sale by or on order of a physician, or any other practitioner licensed by the law of the State in which he practices
More informationMANUFACTURERS OF: INSTRUMENTS & SERVICES. Page:01
Page:01 Introduction: LAB CARE MAKE make Autoclaves are designed and fabricated for steam sterilization process to Kill micro-organism through the application of saturated steam under pressure to suit
More informationPortable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU
Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU OPERATING INSTRUCTIONS PCR-06-01 PCR-08-01 PCR-10-01 3058080 V170223 PURCHASE INFORMATION Thank you for choosing a Chigo Portable Air Conditioner.
More informationNC SERIES. Horizontal Steam Sterilizers
NC SERIES Horizontal Steam Sterilizers NC 300/430/570/710 HORIZONTAL STEAM STERILIZERS Our continuous investments in research and development have enabled us to develop our horizontal steam sterilizer
More informationSUPER CLEAN FILTER PUMP USER S MANUAL 29P414XX/29P415XX/29P416XX/29P417XX
FP13-15-GB SUPER CLEAN FILTER PUMP USER S MANUAL 29P414XX/29P415XX/29P416XX/29P417XX 1 Attention: Read all instructions carefully before installing filter pump. TABLE OF CONTENTS Instruction...... 2-3
More informationPRODUCT CATALOG MEDICAL AUTOCLAVE.
PRODUCT CATALOG MEDICAL AUTOCLAVE www.biolabscientific.com MEDICAL AUTOCLAVE Designed for sterilization of solid instruments, medical class N autoclave is a non vacuum sterilizer which removes air from
More informationMaxLite Polygon Linear LED Light
General Safety Information For Contractors: WARNING: Light fixtures should only be installed by qualified electricians. Be sure to use proper mounting method and hardware rated for the weight of the light
More informationHANDY/STICK 2-WAY VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H055
HANDY/STICK 2-WAY VACUUM INSTRUCTION MANUAL For Authentic Monster Replacement Parts Call 888.896.8786 Model #: H055 IMPORTANT SAFE T SAVE THESE INSTRUCTIONS When using an electrical appliance, basic safety
More informationOperating / User Manual
UniARM Surgical Support System Operating / User Manual Version 1.1 MITAKA KOHKI Co., Ltd. 1. Introduction Introduction Thank you for purchasing the UniARM for use in surgical procedures. To use the device
More informationSplit Air Conditioner
Change for Life Split Air Conditioner Installation Manual Residential Air Conditioners MODEL: GWH09MA-A3DNXXA GWC09MA-A3DNXXA GWH12MB-A3DNXXA GWC12MB-A3DNXXA GWH09MB-D3DNXXD GWC09MB-D3DNXXD GWH12MB-D3DNXXD
More informationSlim Line Service Manual
Slim Line Service Manual SLIM LINE Juice Machine Din återförsäljare / Your retail dealer S / EN...... Rev. 090914 List Of Contents Index Main Index List of contents page 2 General description page 3 Dispenser
More informationInstrument Processing. Midmark Animal Health Products
Instrument Processing Midmark Animal Health Products Midmark Sterilizers because your clients trust you. When your clients come to you, they are entrusting you with an important member of their family,
More informationINSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO VALVE
INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO--175 8 VALVE Release Date: March 24, 2004 Publication Number: 620917902INS Revision Date: April 08, 2014 Revision: E Visit the Cornelius web site
More informationEBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL CD425 (1018110) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News, VA 23606 Tel: 757 873 6800 Fax: 757 873 3632 Website: www.ebacusa.com
More informationP.N Rev A ELECTRIC HOT WATER DISPENSER User Manual BVSTWD7915 Series MODEL
User Manual MODEL ELECTRIC HOT WATER DISPENSER BVSTWD7915 Series www.oster.ca P.N. 166025 Rev A IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed
More information5) Do not start or stop the unit by inserting or pulling out the power plug.
3058080 V170306 PURCHASE INFORMATION Thank you for choosing a Soleus Air Portable Air Conditioner. This Owner s Manual will provide you with valuable information necessary for the proper care and maintenance
More informationClass B Autoclaves Instruction for Use
Master in Sterilization Class B Autoclaves Instruction for Use Table of Contents General Scope of Manual... 3 Intended Us... 3 General Safety Instructions... 3 Standards and Directives... 3 Symbols...
More informationInstallation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)
Installation Viking Range, LLC Front Street Greenwood, Mississippi 890 USA (66) 455-00 For product information, call -888-845-464 or visit the Viking Website at vikingrange.com U L C U L 4 Series Built-In
More informationSN210/310/510, SQ510/810C
Laboratory Autoclave SN210/310/510, SQ510/810C SN210/310/510, SQ510/810C The highest temperature of 135deg.C Upwards opening lid SN210/310/510 SQ500(low height type) SQ510/810C 1 / 5 Features 1.Featured
More informationModel No.: PS08-01 PS10-01 Ref: KY80 KY100
8,000/10,000/12,000 BTU Portable Air Conditioner Operating Instructions Model No.: PS08-01 PS10-01 Ref: KY80 KY100 Model No.: PS12-03 Ref: KY120 3119233 V160310 Thank you for choosing a Soleus Air Portable
More informationDELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4
DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4 Congratulations on your purchase of an Aquaport Executive Filtered Water Cooler This unit is easy to install and provides great tasting chilled
More informationThe Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.
The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury. The Warning signal alerts you to potential hazards or unsafe practices which,
More information