MHTR1D Resistance humidity sensor. MHTR1D humidity and temperature sensor module Data sheet
|
|
- Baldwin Carter
- 5 years ago
- Views:
Transcription
1 Resistance humidity sensor Humidity and temperature sensor module Manufacturer: Ningbo Jiangbei Junrong Electron Technology Co., Ltd Phone: , , Web site: Address: no.7 nijiayan road, jiangbei district, Ningbo China Name Model Humidity and temperature sensor module Ningbo jiangbei junrong electron technology Co., ltd product developed department Frame Emend Emend Emend
2 1. General The is designed by Ningbo Junrong Electron. This product with characteristics of stable, best price, good crossing-over and with temperature retrieves performance. It is also ideal to measure temperature and humidity in air-conditioning, dehumidifier,humidifier. 2. Application Air-conditioning, dehumidifier,humidifier, Electron, pharmaceutical industry, food processing, warehouses, tobacco, textile, weather, libraries and museum. 3. Shape 4. Model Model encapsulation shape without shell detail to the picture There are three models according to with or without Temperature and humidity sensor Specification humidity measuring module, without temperature element temperature and humidity measuring module, with NTC heat sensitive resistance temperature and humidity measuring module, with LM35 temperature sensor (1) Power supply (vin) DC 5V±5% (2) Electrical current 1.6MA (max 3mA) (3) Temperature operating range 0 ~ 50 (4) Humidity operating range under 95%RH (5) Humidity measuring range 30 ~ 90%RH (6) Temperature storing range 0 ~ 70 (7) Humidity storing range lower 95%RH (non dew point) (8) Humidity measuring Accuracy ±5%RH ( at 25, 60%RH vin=5.0v 1.65`1.95V ) (9) Typical humidity data responding to output Based as the power supplied by 5.0V,at 25 Humidity (%RH) Voltage (V) Humidity (%RH) Voltage (V) Remark: standard voltage output can adjust according to the customer desire. (10) Temperature testing feature 1 ±2% R (25 )=10KΩ B=3950 ±2% V/ accuracy: ±1.5 (11) Temperature dependence (reference) ±5%RH (5.00V DC, 40 80%RH, at 25, 0-50 ) (12) Voltage dependence (reference) ±5%RH (at 25,40 80%RH,5.00V (13) Measure: 34.7x21.5x10 mm DC, V)
3 6. Note (1) Avoid using when dew point (2)Avoid putting the product in the erode atmosphere environment for long time (3)please be careful when connecting, no electrode protecting (4) Storage condition Temperature range 10 ~ 40 Humidity range under 60%RH Chart1. exterior picture( type). Electric connecting Electric tie-in Content 1 Power supply DC 5V 2 Humidity output 3 GND 4 Temperature output Chart 2. Connection example Humidity measure circuit Hot sensitive resisitance
4 Chart 3. Electric connection. Chart 4. Standard characteristic picture Output voltage V DC 1. +5V(red) 2.Hout(yellow) 4.Tout(white or green) 3.Gnd(black)
5 Table2.Hot sensitive resistance standard data table ::10KΩ 3950:: R-T Sub-degree table T R T R T R T R
Relative Humidity Transmitters
Relative Humidity Transmitters Standard Accuracy Series 730,732, ± 2% RH or Low Cost 733 and 734 Design ± 3 % RH Analog : 2-Wire (4-20mA) or User-Selectable (0-1V, 0-5V, 0-10V or 0-1mA) CE-approval TYPICAL
More informationIntelligent Infrared Carbon Dioxide Module (Model: MH-Z14A)
Intelligent Infrared Carbon Dioxide Module (Model: MH-Z14A) User s Manual V1.01 Valid from Sep 24 th, 2015 Zhengzhou Winsen Electronics Technology CO., LTD. Statement The copyright of this manual belongs
More informationHUM-M2 Humidity Sensor Module Description
HUM-M2 Humidity Sensor Module Description Humidity Sensor Modules are designed for environment monitoring and controlling in industrial, commercial and other buildings. These transmitters can be used for
More informationInfrared Carbon Dioxide Sensor Module CM1106SL
Infrared Carbon Dioxide Sensor Module CM1106SL Application Ventilation system Central air-conditioning IAQ monitor Agricultural Planting, Plant growing Brief introduction Single Beam (Single light source,
More informationAir-Quality Detection Module. User s Manual
Air-Quality Detection Module (Model:ZP07-MP901) User s Manual Version: 1.1 Valid from 2014-11-10 Zhengzhou Winsen Electronics Technology Co., Ltd Statement This manual s copyright belongs to Zhengzhou
More informationHTF3000LF PVH-3.3 TEMPERATURE AND HUMIDITY MODULE
TEMPERATURE AND HUMIDITY MODULE Compliant with RoHS recommendations Based on the rugged HS1101LF humidity sensor, HTF3000LF PVH-3.3 is a dedicated humidity and temperature transducer designed for OEM applications
More informationRoom Air Quality Sensors
1 961 1961P1 1961P2 QPA2 QPA2D Room Air Quality Sensors QPA2 With maintenance-free photoacoustic CO 2 sensing element and depending on the type of sensor VOC 1) sensing element, based on a heated tin dioxide
More informationDuct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.
Features Humidity and Temperature outputs in same unit With or without display Humidity output 0-10 Vdc or 4-20 ma Temperature output 0-10 Vdc or 4-20 ma As option passive direct temperature output PT1000,
More informationAir-Quality Detection Module. User s Manual
Air-Quality Detection Module (Model:ZP01-MP503) User s Manual Version: 1.4 Valid from 2014-11-01 Zhengzhou Winsen Electronics Technology Co., Ltd ISO9001 Certificated Company Statement This manual s copyright
More informationCO2 Gas Sensor Module (#27929)
Web Site: www.parallax.com Forums: forums.parallax.com Sales: sales@parallax.com Technical: support@parallax.com Office: (916) 624-8333 Fax: (916) 624-8003 Sales: (888) 512-1024 Tech Support: (888) 997-8267
More informationFIS SMART SENSOR U (Draft 1) June 25, 2001
FIS200-0 SPECIFICATIONS (Draft ) MODEL PARTS NAME SPECIFICATION No. DATE OF ISSUE FIS200-0 SMART SENSOR U-004-0 (Draft ) June 25, 200 Distribution Number of copies Date Customer Distributor FIS Signatures
More informationInfrared Carbon Dioxide Sensor Module CM1107-Dual Beam
Infrared Carbon Dioxide Sensor Module CM1107-Dual Beam CM1107 Specification Working temperature -10 ~+50, 5~95%RH Introduction Dual beam (single light source, dual wavelength) CM1107 CO2 gas sensor module
More informationIT COOLING CLOSE CONTROL AIR CONDITIONERS PRECISION AIR CONDITIONERS WITH INVERTER TECHNOLOGY FOR STABLE ROOM CONDITIONS
IT COOLING CLOSE CONTROL AIR CONDITIONERS PRECISION AIR CONDITIONERS WITH INVERTER TECHNOLOGY FOR STABLE ROOM CONDITIONS IT COOLING CLOSE CONTROL AIR CONDITIONERS Extreme precision in temperature and humidity
More informationScanning Laser Range Finder Smart-URG mini UST-10LN Specification
Date: 2016.3.24 Scanning Laser Range Finder Smart-URG mini UST-10LN Specification Symbol Amended Reason Pages Date Corrector Amendment No Approved by Checked by Drawn by Designed by UST-10LN Specification
More informationOzone Gas Sensor. (Model:MQ131 High Concentration) Manual. Version: 1.4. Valid from: Zhengzhou Winsen Electronics Technology Co.
Ozone Gas Sensor (Model:MQ131 High Concentration) Manual Version: 1.4 Valid from: 2015-03-10 Zhengzhou Winsen Electronics Technology Co., Ltd Statement This manual copyright belongs to Zhengzhou Winsen
More informationRoom air quality sensors
1 961 1961P01 QPA20 QPA20 D 1961P02 Room air quality sensors QPA20 Use With maintenance-free CO 2 sensing element based on optical infrared absorption measurement (NDIR 1) ) and depending on the type of
More informationDuct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering
Duct Humidity and Temperature Transmitter DHT Apr. 17 Features Humidity and Temperature outputs in same unit Humidity output 0-10 Vdc or 4-20 ma Temperature output 0-10 Vdc or 4-20 ma As option passive
More informationNTC THERMISTOR SENSOR PERFORMANCE
NTC THERMISTOR SENSOR PERFORMANCE Accuracy, Interchangeability, Beta Tolerance, Tolerance Comparison, Stability, Drift, and Moisture Induced Failure When designing the best temperature probe for a specific
More informationSensepoint XCL Fixed Gas Detector
Gas Detec on Sensepoint XCL Fixed Gas Detector Quick Start Guide Sensepoint XCL Fixed Gas Detector Quick Start Guide Read and understand the Sensepoint XCL Operating Instructions before installing, operating
More informationSelecting the right humidity sensor for your application
Selecting the right humidity sensor for your application Humidity is the presence of water in the air. The amount of vapour can affect human comfort as well as many manufacturing processes. Monitoring
More informationProduct Classroom. Smart sensor, photoelectric sensor, inudctive proximity sensor, laser displacement sensor, area sensor
Title Delta Smart Sensors Date March, 2017 Related Products Key words Smart sensor, photoelectric sensor, inudctive proximity sensor, laser displacement sensor, area sensor Smart sensor, photoelectric,
More informationU86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS
SPECIFICATIONS Mountable with O-ring seal Stainless Steel wetted surfaces Amplified ASIC calibrated Absolute, sealed gage Cable option Analog output SENT Output Optional (contact factory for details) FEATURES
More informationDuct Air Quality Sensors
1 962 QPM2102D QPM2160D, QPM2162D QPM2100, QPM2102 QPM2160, QPM2162 Duct Air Quality Sensors QPM21 With maintenance-free CO 2 sensing element based on optical infrared absorption measurement (NDIR 1 )
More informationLaser Particle Sensor Module PM2008M
Laser Particle Sensor Module PM2008M Application Air purifier, air quality monitor Ventilation system, air conditioner with purifying function Auxiliary product of consumer electronic products Environmental
More informationQFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature
1 864 1864P01 Symaro Duct Sensors for relative humidity and temperature QFM21 Operating voltage AC 24 V / DC 13535 V Signal output DC 010 V / 420 ma for relative humidity Signal output DC 010 V / 420 ma
More informationLaser Particle Sensor Module PM2008M
Laser Particle Sensor Module PM2008M Application Air purifier, air quality monitor Ventilation system, air conditioner with purifying function Auxiliary product of consumer electronic products Environmental
More informationDuct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature
1 882 1882P01 Symaro Duct Sensors for relative humitidy (high accuracy) and temperature QFM31 Use Examples Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 4 20 ma for relative humidity and
More informationan ISO9001 company APPLICATION NOTES FOR TGS2611 Application Notes for Methane Gas Detectors using TGS2611
Application Notes for Methane Gas Detectors using TGS2611 an ISO9001 company The TGS2611 methane gas sensor has been presorted into groupings which will allow users to simplify the manufacturing process
More informationElectro Optical Components, Inc.
Electro Optical Components, Inc. 5464 Skylane Boulevard, Suite D, Santa Rosa, CA 95403 Toll Free: 855-EOC-6300 www.eoc-inc.com info@eoc-inc.com Technical Note GUVx-T1XC-3LWx GUVx-T11GC-I8LWx Probe Application
More informationThermohygrometer with Single Type K Input and Superheat Function
User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Thermohygrometer with Single Type K Input and Superheat Function with
More informationPrecision air conditioners with inverter technology for stable room conditions
Precision air conditioners with inverter technology for stable room conditions Extreme precision in temperature and humidity control In laboratories, archives, museums, the tobacco, textile and pharmaceutical
More informationan ISO9001 company APPLICATION NOTES FOR TGS2610 Application Notes for LP Gas Detectors using TGS2610
Application Notes for LP Gas Detectors using TGS2610 an ISO9001 company The TGS2610 LP gas sensor has been presorted into groupings which will allow users to simplify the manufacturing process for LP gas
More informationQFM21... Duct sensors. Symaro. for relative humidity and temperature
1 864 1864P01 Symaro Duct sensors for relative humidity and temperature QFM21... Operating voltage AC 24 V / DC 13.5...35 V Signal output DC 0...10 V / 4 20 ma for relative humidity Signal output DC 0...10
More informationQFM21... Duct Sensors. Siemens Building Technologies HVAC Products
For latest prices and delivery to your door visit MyTub Ltd - 0845 303 8383 - wwwmytubcouk - info@mytubcouk 1 864 1864P01 Symaro Duct Sensors for relative humidity and temperature QFM21 Use Operating voltage
More informationEL-OEM-3 OEM Packaged Voltage Data Logger
OEM Packaged Voltage Data Logger ORDERING INFORMATION Standard Data Logger (Data Logger only. EasyLog software available from ) EL-OEM-3 FEATURES PCB Mounted (2.54mm pitch, header sockets) 0-2.4 Volt d.c.
More informationProduct Specifications
For Reference Only Product Specifications HIS-06-N Humidity HIS-06-N Specification 2004/02/23 1/7 Contents 1. Application 2. Type Designation 3. Outline Dimensions 4. Ratings 5. Electrical Characteristic
More information(HR) Heating Resistors
Version: January 12, 2017 (HR) Heating Resistors Token Electronics Industry Co., Ltd. Web: www.token.com.tw Email: rfq@token.com.tw Taiwan: No.137, Sec. 1, Zhongxing Rd., Wugu District, New Taipei City,
More informationTrueAlarm Analog Sensing
TrueAlarm Analog Sensing UL, ULC Listed* Addressable Duct Sensor Housings with TrueAlarm Photoelectric Sensor; Available with Multiple Relay Features Compact air duct sensor housing with clear cover to
More informationHumidity Measurement Technology pros & cons. Helping you make a better measurement.
Humidity Measurement Technology pros & cons Helping you make a better measurement. Webinar Presenters & Humidity Experts Bruce McDuffee Michael Boetzkes Agenda & Takeaways Agenda Parameter review Mechanical
More informationQFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature
1 864 1864P01 Symaro Duct Sensors for relative humidity and temperature QFM21... Use Type summary Operating voltage AC 24 V or DC 13.5...3 Signal output DC 0...10 V for relative humidity Signal output
More informationPiezo-electric Devices Precaution Usage
Version: January 16, 2017 Piezo-electric Devices Precaution Usage Token Electronics Industry Co., Ltd. Web: www.token.com.tw Email: rfq@token.com.tw Taiwan: No.137, Sec. 1, Zhongxing Rd., Wugu District,
More informationLaser Particle Sensor Module PM2009
Laser Particle Sensor Module PM2009 Application Air purifier, air quality monitor Ventilation system, air conditioner with purifying function Auxiliary product of consumer electronic products Environmental
More informationDOMESTIC HOT WATER Follow operational sequence
DOMESTIC HOT WATER Follow operational sequence Turn Winter/Summer selector to Summer position. The display is switch on. Go to section A Error 110 flashing Error 131 flashing Turn the selector to reset
More informationRoom Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature
1 858 1858P01 1858P02 1859P02 Symaro Room Sensors for relative humidity (high accuracy) and temperature AQF3150 QFA31 Use Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 4 20 ma for r h and
More informationEasyLog Data Logger Series
EasyLog Data Logger Series Overview EasyLog model EL-USB series products are a line of low cost, compact, battery-operated data loggers with built-in memory and USB interface. Each product in the line
More informationDescription of Functions
Quality is our message Chapter 3 Description of Functions Contents Page 1. Function Tables...3-2 2. Function Descriptions...3-4 3. Truth Tables...3-11 4. IPM Block Diagrams...3-13 5. Timing Charts...3-21
More informationUsing the DewMaster Deluxe Dew Point/ Humidity Hygrometer
JAN 0 ::0 AM SERVOLOCK APPLICATION NOTE 0_0_ Rev Using the Deluxe Dew Point/ Humidity Hygrometer The Model is a versatile, multi-function, optical chilled mirror hygrometer designed to continuously measure
More informationAIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW
AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW Row Cooling Precision Air Conditioner Cooling Capacity: 26.2kW~68.6kW CHILLROW is installed closely with the server cabinets and refrigerating independently. The
More informationTEMPERATURE SENSORS FOR OUTDOOR USAGE 08.12a
TEMPERATURE SENSORS FOR OUTDOOR USAGE 08.12a DESCRIPTION AND APPLICATION These resistance-type sensors are intended for contact temperature measurement of gaseous substances. The sensor consists of a metal
More informationheatersteam unprecedented precision and reliability
heatersteam unprecedented precision and reliability Electric heater humidification Reliable and precise technology for high-tech applications. Steam production is modulated with the highest precision,
More informationHygro and Hygrothermo Transducers (capacitive) for climatic applications
Data sheet 907020 Page 1/7 Hygro and Hygrothermo Transducers (capacitive) for climatic applications To measure relative humidity and temperature For versatile climatic applications and ventilation For
More informationInstruments Div. Rev.1 Sensing Module Approval Check Drawer Rev.2 Rev.3 RHI-112A
PRODUCT SPECIFICATION RHI-112 A SP-03-D-080** 1 PRODUCT MODEL NO. SHINYEI KAISHA Electronic Issued Jan. 30, 2008 Temperatur&Humidity Instruments Div. Rev.1 Sensing Module Approval Check Drawer Rev.2 Rev.3
More information1. Product description
1. Product description Technical data sheet clima DL-110 Available inputs and outputs The clima DL-110 is a universal room controller. It is suitable for controlling static heating/cooling systems (like
More informationMS4525DO SPECIFICATIONS FEATURES APPLICATIONS
FEATURES PSI Pressure Ranges PCB Mountable Digital Output Barbed Pressure Ports APPLICATIONS Blocked Filter Detection Altitude and Airspeed Measurements Medical Instruments Fire Suppression System Panel
More informationINSTALLATION & USER MANUAL
INSTALLATION & USER MANUAL HC Digital Automatic Humidistat (Y3760) CONTROLS 506808-01 3/2016 Supersedes 6/2011 picture goes here THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE NOTICE
More informationIntroduction Portable Meters Transmitter Probes RELATIVE HUMIDITY
S E C T I O N 10 C O N T E N T S N A V I G A T I O N Introduction.................... 10.2 Portable Meters................. 10.3 Transmitter..................... 10.9 Probes......................... 10.10
More informationInstallation Guide IM 1248
Installation Guide IM 1248 BACnet Thermostat for Heat Pump Units Group: Controls Part Number: IM 1248 Date: August 2015 Table of Contents Installation Guide Heat Pump.... 2 Applicable Models... 2 Mounting
More informationEST User Manual. (Please read this manual carefully before using)
EST-1000 Handheld Intelligent Toxic Gas Detector User Manual (Please read this manual carefully before using) ENVIRONMENTAL SENSOR TECHNOLOGY CO.INC. Contents I. Product Overview...1 II. Product Description...1
More informationSERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION
R SERIES 35-703 120 VAC Microprocessor-Based Intermittent Pilot Ignition Control F-35-703 July 2016 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge and inter-purge timings
More informationFTK+ Application. Types Available. Duct sensor for humidity and temperature. Datasheet
FTK+ Duct sensor for humidity and temperature Datasheet Subject to technical alteration Issue date: 03.04.2018 A002 Application Duct humidity and temperature sensor in new hinged lid enclosure USE for
More informationSpecification Document. Heat-resisting Type Water Leakage Sensor FR-AD
TS-KS-W1164-8 To: Specification Document Heat-resisting Type Water Leakage Sensor FR-AD Date:( ) System Equipment Division Electronic Materials & System Equipment Group TATSUTA Electric
More informationMEMS Carbon Monoxide Gas Sensor. (Model No.:GM-702B) Manual. Version: 1.1. Valid from: Zhengzhou Winsen Electronics Technology Co.
MEMS Carbon Monoxide Gas Sensor (Model No.:GM-702B) Manual Version: 1.1 Valid from: 2017.11.23 Zhengzhou Winsen Electronics Technology Co., Ltd Statement This manual copyright belongs to Zhengzhou Winsen
More informationSpecification Document. Color-changing Recovery Type Water Leakage Sensor AD-RS
TS-KS-W11608-1 To: Specification Document Color-changing Recovery Type Water Leakage Sensor AD-RS Date:( ) System Equipment Division Electronic Materials & System Equipment Group TATSUTA
More informationAmmonia Gas Sensor. (Model:MQ137) Manual. Version: 1.4. Valid from: Zhengzhou Winsen Electronics Technology Co., Ltd
Ammonia Gas Sensor (Model:MQ137) Manual Version: 1.4 Valid from: 2015-03-10 Zhengzhou Winsen Electronics Technology Co., Ltd Statement This manual copyright belongs Zhengzhou Winsen Electronics Technology
More informationLCF Touch (from firmware version 1.7)
LCF Touch (from firmware version 1.7) Electronic Fan Coil Thermostat with Touch Display (Flush mounting) Datasheet Subject to technical alteration Issue date: 26.1.216 Application Modern design flush mounting
More informationEasyLog Data Logger Series
EasyLog Data Logger Series Overview EasyLog model EL-USB series products are a line of low cost, compact, battery-operated data loggers with built-in memory and USB interface. Each product in the line
More information973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS
Portable Industrial Chilled Mirror Hygrometer Fundamental drift free humidity measurement Integral frost/dew point measuring head Internal sample pump Optimal Response Injection System for fast measurement
More informationManual Zhengzhou Winsen Electronics Technology Co., Ltd
ZP04 Flammable Gas Detection Module Manual Zhengzhou Winsen Electronics Technology Co., Ltd Statement This manual s copyright belongs to Zhengzhou Winsen Electronics Technology Co., LTD. Without the written
More informationSHIMADEN DIGITAL INDICATORS
Shimaden, Temperature and Humidity Control Specialists C %RH MICROPROCESSOR-BASED SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.25% High Accuracy Indication User-Selectable
More informationSmoke Sensor. (Model:MQ-2) Manual. Version: 1.4. Valid from: Zhengzhou Winsen Electronics Technology Co., Ltd
Smoke Sensor (Model:MQ-2) Manual Version: 1.4 Valid from: 2015-03-10 Zhengzhou Winsen Electronics Technology Co., Ltd Statement This manual copyright belongs to Zhengzhou Winsen Electronics Technology
More informationTechnical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application
Document No. CE1N1961 QPA20 Room CO 2 and Air Quality Sensors Description The Q-Series Room Carbon Dioxide (CO 2 ) and Air Quality Sensors are especially suited for applications where precise, stable carbon
More informationRoom Temperature Controller
3 022 Room Temperature Controller for two-pipe fan coil units with electrical heater RCC20 Outputs for on / off valve actuator and electrical heater Output for three-speed fan Control depending on the
More informationZP04 Flammable Gas Detection Module (Model:ZP04) Manual V1.1. Zhengzhou Winsen Electronics Technology Co., Ltd
ZP04 Flammable Gas Detection Module (Model:ZP04) Manual V. Zhengzhou Winsen Electronics Technology Co., Ltd Statement This manual s copyright belongs to Zhengzhou Winsen Electronics Technology Co., LTD.
More informationDuct and Rough Service Carbon Monoxide Sensor
Product Identification and Overview Duct and Rough Service Carbon Monoxide Sensor BAPI s Carbon Monoxide Sensor offers enhanced electrochemical sensing with outstanding accuracy at low concentrations.
More informationHM1520LF Relative Humidity Module
SPECIFICATIONS Tubular form for through wall mounting Product free from Lead, Cr(6+), Cd and Hg Calibrated, linear voltage for easy electronic interface Typical 1 to 1.6 Volt DC output for 0 to 20% RH
More informationHygro and hygrothermo transducers (capacitive) for HVAC monitoring
Data Sheet 90.7021 Page 1/6 Hygro and hygrothermo transducers (capacitive) for HVAC monitoring for measuring relative humidity and temperature for HVAC applications as indoor, wall and duct versions special
More informationChapter 7. Troubleshooting
Chapter 7 Troubleshooting Table of Contents Page 1 Troubleshooting... 7-2 2 Failure analysis charts... 7-2 3 Alarm factor tree analysis chart... 7-8 7-1 1 Troubleshooting An IPM has various integrated
More informationRoom Temperature Controllers
3 021 Room Temperature Controllers for two-pipe fan coil units RCC10 Output for on / off valve actuator Outputs for three-speed fan Control depending on the room or return air temperature (RCC10) Automatic
More informationHygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications
Data Sheet 907020 Page 1/9 Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications For measuring relative humidity and temperature For versatile climatic applications and ventilation
More informationOX100, OX102. Limiting-current type Oxygen Analyzer OX100, OX102. Bulletin 11M10A01-03E
Limiting-current type Oxygen Analyzer OX00, OX02 OX00, OX02 Limiting-current type Oxygen Analyzer One Instrument measures 00 ppm to 25% Oxygen Simple "One Touch" Calibration Self Diagnostics Assure High
More informationTS105-10L5.5MM Thermopile Sensor
SPECIFICATIONS Thermopile IR-Sensor For Contactless Temperature Measurement Single Element For Industrial Pyrometers Silicon Lens Accurate Reference Sensor Thermopiles are mainly used for contactless temperature
More informationADVANCED CLIMATE CONTROL & DRY STORAGE SOLUTIONS FOR WAREHOUSES & HANGARS W W W. K N O L L T E C H. C O M
ADVANCED CLIMATE CONTROL & DRY STORAGE SOLUTIONS FOR WAREHOUSES & HANGARS W W W. K N O L L T E C H. C O M COMPANY PROFILE 2016 Knolltech Ltd- established at 1994. The company manufacture specialty products
More informationHumidity Measurement Technology Pros & Cons. Helping you make a better measurement.
Humidity Measurement Technology Pros & Cons Helping you make a better measurement. Webinar Presenters & Humidity Experts Bruce McDuffee Michael Boetzkes Agenda & Takeaways Agenda Parameter review Mechanical
More informationTECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2
FEATURES: Closed Loop Design (Class A Wiring) Microprocessor Based System Intelligent Distributed System Structure Quick Response Time Fire Alarm in
More informationMICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011
MICHELL GROUP Advanced Industrial Hygrometry and Process Instrumentation Company Profile, 2011 Who is the Michell Group? Leading in the world of solutions for humidity and gas analysers More than 30 years
More informationRoom Temperature Controller
3 22 Room Temperature Controller for two-pipe fan coil units with electrical heater RCC2 Outputs for on / off valve actuator and electrical heater Output for three-speed fan Control depending on the room
More informationPRODUCT SPECIFICATION
Document No.:JSS144.2016 Revision:A0 PRODUCT SPECIFICATION ALKALINE AAA SIZE BATTERY Type Designation : LR03UP/AAA Prepared by : Checked by : Approved by : Issued Date : 2016-04-03 Zhongyin (Ningbo) Battery
More informationLCF Touch Modbus Datasheet Application Security Advice Caution
LCF Touch Modbus Electronic Fan Coil Thermostat with Touch Display (Flush mounting) Datasheet Subject to technical alteration Issue date: 3.11.214 Application Modern design flush mounting fan coil room
More informationWall-mounted room thermostat with LCD
3 182 Wall-mounted room thermostat with LCD for VAV heating and cooling systems RDG400 Modulating PI control Control depending on the room or the return air temperature Output for DC 0 10 V actuator and
More information5230IG. Thermotouch 3.2aP Wireless Heating Thermostat
5230 Thermotouch 3.2aP Wireless Heating Thermostat 1 Introduction Thermotouch 3.2aP wireless thermostat Thermotouch 3.2aP is a wireless thermostat, which is designed for electric floor heating systems
More informationDigital Control Module Replacement Manual
Digital Control Module Replacement Manual Commercial Backbars Z2440 Rev. 10.28.16 REMOVAL INSTRUCTIONS - Digital Control Removal Tools needed for digital control removal. 1. Screwdriver 2. Wire Cutters
More informationEL-USB-TC Thermocouple Data Logger with USB Interface
Thermocouple Data Logger with USB Interface ORDERING INFORMATION Standard Data Logger EL-USB-TC (Data Logger, Measurement Leads, Software on CD and Battery) Replacement Battery K-type Probe BAT 3V6 1/2AA
More informationWeb Base Home Monitoring System
Web Base Home Monitoring System Group B: Jon Carver Jason Heintz Dennis Seda Sean Willis Term: Fall 2010 Agenda Goals and Objectives Specifications Implementation and Design Test Plan Successes Design
More informationUNISONIC TECHNOLOGIES CO., LTD 88NXX
UNISONIC TECHNOLOGIES CO., LTD 88NXX BUILT-IN DELAY HIGH-PRECISION OLTAGE ECTOR DESCRIPTION The UTC 88NXX is a high-precision voltage detector developed basing on CMOS technology. The detection voltage
More informationMS4525 SPECIFICATIONS
SPECIFICATIONS PCB Mounted Pressure Transducers Amplified Ratiometric Analog Output Differential, Gage, Absolute, Compound, & Vacuum Temperature Compensated 3.3 or 5.0 V DC Supply Voltage The MS4525 is
More informationDETECTORS, REMOTE CONTROLS & VARIOUS ACCESS.
Description Code Page DETECTORS, REMOTE CONTROLS & VARIOUS ACCESS. TEMPERATURE & HUMIDTY DETECTORS ROOM TEMPERATURE DETECTORS SAB - SCB 9.2 INDUSTRIAL-TYPE ROOM TEMPERATURE DETECTORS SAA... 9.2 OUTSIDE
More informationSERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)
R SERIES 35-70 120 VAC Microprocessor-Based Direct Spark Ignition Control F-35-70 November 2015 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge and inter-purge timings
More informationLCF Touch. Electronic Fan Coil Thermostat with Touch Display (Flush mounting) Datasheet. Application. Security Advice Caution.
LCF Touch Electronic Fan Coil Thermostat with Touch Display (Flush mounting) Datasheet Subject to technical alteration Issue date: 3.11.214 Application Modern design flush mounting fan coil room thermostat,
More informationNH Series. Electric Steam Humidifiers. Designed for installation flexibility while maintaining precise humidification control
NH Series Electric Steam Humidifiers Designed for installation flexibility while maintaining precise humidification control NORTEC NH Series humidifiers resolve demanding application needs. commercial
More informationDräger Polytron 5700 IR Detection of flammable gases and vapours
Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive
More information