Installation/Care/Use Manual

Size: px
Start display at page:

Download "Installation/Care/Use Manual"

Transcription

1 HTHB8*, HTHBLR*, HTHB8*, HTHB8*3, HTHBLR* HTHB8NF*, HTHBLRNF*, HTHB8NF*, HTHB8NF*3, HTHBLRNF* Installation/Care/Use Manual Hydroboost In Wall Bottle Filling Station HTHB8* HTHB8NR* HTHB_LR* HTHB_LRNR* Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these instructions inside the fountain for future reference. IMPORTANT ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON IMPORTANT! INSTALLER PLEASE NOTE. THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM. WE SUGGEST THAT THE BOTTLE FILLER BE PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER (GFCI) /" O.D. TUBE WATER INLET TO COOLER 3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY BUILDING WATER INLET NOTE: WATER FLOW DIRECTION SERVICE STOP (NOT FURNISHED) FIG. FIG C (Rev. E 6/0)

2 HTHB8*, HTHBLR*, HTHB8*, HTHB8*3, HTHBLR* HTHB8NF*, HTHBLRNF*, HTHB8NF*, HTHB8NF*3, HTHBLRNF* HTHP8*, HTHBLR*, HTHP8NR*, HTHBLRNR* ROUGH IN FIG C (Rev. E 6/0) PAGE

3 HTHB8*, HTHBLR*, HTHB8*, HTHB8*3, HTHBLR* HTHB8NF*, HTHBLRNF*, HTHB8NF*, HTHB8NF*3, HTHBLRNF* INSTALLATION INSTRUCTIONS. Install mounting frame. See mounting frame instructions.. Install remote chiller. See chiller instructions. 3. EWF3000 WATERSENTRY PLUS FILTER INSTALLATION (Filtered units only. For non filtered units proceed to step b) NOTICE: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. )These filter kits must be installed in compliance with all state and local laws and regulations governing the installation and use of this product. Maximum inlet water temperature 00 F (38 C). ) See filter instructions for filter assembly. Insert 3/8" elbow fitting into the inlet side of filter head, insert /" polytube or /" x 90 elbow into outlet of filter head prior to mounting the filter head assembly into the remote chiller 3) Mount filter head to the side of the remote chiller using the filter mounting bracket and screws supplied. CAUTION: If supply pressure will ever exceed 00 psi, install a pressure regulator to limit the inlet pressure to the filter to 00 psi or below. DO NOT ATTACH HOT WATER LINE TO FILTER. To make connections on the filter head, loosen locknut. Push the tube end past both orings to a positive stop in the filter head recess approx. ", locknut may have to be backed out a little more. Screw the locknut hand tight to seal (See Fig. 5). Ends of tubing must be cut square and free of burrs and sharp ends that could cut or nick the orings. NOTE: SCREW THE LOCKNUT HAND TIGHT TO SEAL FIG. 5 a. Make water supply connections for Fltered units. Install a shutoff valve and union connection to building water supply (valve and union not provided). Turn on the water supply and flush the line thoroughly. b. Make water supply connections for Non Fltered units. Install a shutoff valve and union connection to building water supply (valve and union not provided). Turn on the water supply and flush the line thoroughly. intsall the inline strainer between the valve and the cooler. The inline stainer is not installed on filtered units. 5. (Filtered units only. For non filtered units proceed to step 7) Make connection between filter head and building supply line. Insert the 3/8" water line into the inlet side of the filter head by pushing it in until it reaches a positive stop, approximately 3/" (9mm). Install two /" x /" unions (provided) on the chiller. One on the inlet tube, and the other on the outlet tube. 6. Make connection between the filter head and the remote chiller. Insert end of /" O.D. poly tubing from the filter head (provided) into union on chiller inlet 7. Mount the upper panel to the mounting frame, aligning holes in the hinge brackets with holes in the mounting frame (three places). Mount with adaquete size screws (Not provided) Close the door and verify that the lock brackets on the side and bottom of the panel align with the slots on the mounting frame. Also verify that the panel is hanging high enough that it covers the top of the mounting frame. If adjustments need to be made, open the door and loosen the three screws on the hinge and adjust accordingly and then retighten the screws. 8. Connect water line from the water station by inserting the /" O.D. poly tubing into the union on the chiller outlet. 9. Close the upper door and attach the drain fittings to drain tube. Reattach elbow to ptrap and cut waste tube to required length using plumbing hardware and trap as a guide. TO BOTTLE FILLER PLUMBING DIAGRAM FIG. 6 TO BOTTLE FILLER INLET STRAINER CHILLER INLET FILTERED CHILLER FILTER NON FILTERED PAGE C (Rev. E 6/0)

4 HTHB8*, HTHBLR*, HTHB8*, HTHB8*3, HTHBLR* HTHB8NF*, HTHBLRNF*, HTHB8NF*, HTHB8NF*3, HTHBLRNF* 0. Lock the door in place using two set screws (provided) on the side of the panel,and a ¼ x 0 bolt thru the front of the panel into the nut in the frame.. (Filtered nits only) Install filter cartridge, remove filter from carton, remove protective cap, attach filter to filter head by firmly inserting into head and rotating filter clockwise.. Turn water supply on and inspect for leaks. Fix all leaks before continuing. 3. Once unit has been inspected for leaks, and any leaks found corrected, plug Bottle Filler into wall (power cord not supplied on 0V models). Be sure to reinstall fuse to the circuit or switch the circuit breaker back to the ON position. a. (Filtered units) Once power is applied to Bottle Filler, the GREEN LED light should illuminate showing good filter status along with the LCD Bottle Counter. b.(non Filtered units) Once power is applied to Bottle Filler, the LCD Bottle Counter should illuminate. 5. Verify proper dispensing by placing cup, hand, or any opaque object in front of sensor area and verify water dispenses. Note: the first initial dispenses might have air in line which may cause a sputter. This will be eliminated once all air is purged from the line. A steady stream of water assures all air is removed. The sensor has a 30 second maximum ON time. It may be necessary to step away from beam a few times to allow chiller tank to refill. Check for leaks. 6. Mount the lower panel to the mounting frame, aligning holes in the hinge brackets with holes in the mounting frame (three places). Mount with adaquete size screws (Not provided) Close the door and verify that the lock brackets on the side of the panel align with the slots on the mounting frame. If adjustments need to be made, open the door and loosen the three screws on the hinge and adjust accordingly and then retighten the screws. 7. Lock the lower door in place using two set screws (provided) on the side of the panel. HINGE BRACKETS MOUNTING FRAME UPPER PANEL DRAIN LOCATION LOWER PANEL FILTER LOCATION OPTIONAL CHILLER FIG C (Rev. E 6/0) PAGE

5 HTHB8*, HTHBLR*, HTHB8*, HTHB8*3, HTHBLR* HTHB8NF*, HTHBLRNF*, HTHB8NF*, HTHB8NF*3, HTHBLRNF* VERIFY CONTROL BOARD SOFTWARE ) To verify the software program of the control board the unit will need to be shut down and restarted. The chiller (if present) does not need to be shut down and restarted. ) The units lower panel must be open to access the power cord and wall outlet. 3) Shut down the unit by unplugging the power cord from the wall oulet. ) Restart the unit by plugging the power cord back into the wall outlet. 5) Upon start up the bottle count display will show the software designation of BF6, BF7, BF8 or BF9. 6) Reference the BF6BF7BF8 or BF9 instructions for setting the control board. ACCESSING THE PROGRAMING BUTON ) To access the program button the lower panel of the unit must be must be opened. The programming button is loacted at the bottom right corner of the upper panel. This area of the unit is concealed by the lower panel. RESET THE FILTER MONITOR ) Instructions apply to filtered units only. ) Depress the program button for approximately seconds until the display changes then release. The display will change and scroll through three messages: RST FLTR Reset Filter Status LED RST BCNT Reset Bottle Count RNG SET Range Set for IR Sensor If the program button is not pushed again the display will scroll through the three messages above for three cycles and then default back to bottle count and be back in run mode. 3) When the display changes to "RST FLTR", depress the button again. The display will change to show "FLT=". Depress the button again and the display will show "FLTR=0". ) The green LED shoud now be illuminated indicating that the visual filter monitor has been reset. BF6BF7BF8 PROGRAMS SETTING THE CONTROL BOARD RESETTING BOTTLE COUNT ) Depress the program button for approximately seconds until the display changes then release. The display will change and scroll through two messages: RST FLTR Reset Filter Status LED RST BCNT Reset Bottle Count RNG SET Range Set for IR Sensor If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode. ) When the display changes to "RST BCNT", depress the button again. The display will change to show current bottle count value i.e. "BC003383". 3) Depress the button again and the display will change to "BTLCT=0" for approximately seconds and then return to run mode displaying ) You can test the bottle counter by running water approximately 5 seconds to see bottle counter advance. SETTING RANGE OF THE IR SENSOR ) Depress the program button for approximately seconds until the display changes then release. The display will change and scroll through three messages: RST FLTR Reset Filter Status LED RST BCNT Reset Bottle Count RNG SET Range Set for IR Sensor ) If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode. 3) When display shows RNG SET push program button once the display will show current value (can be 0) i.e. RNG = 3. ) Once display shows current value push the program button to scroll through value of 0. Select the desired range setting. 5) Once range is selected allow approximately seconds to pass and then the display will go back to bottle counter and be in run mode. 6) Test bottle filler by placing bottle or hand in front of sensor to make sure water is dispensed C (Rev. E 6/0)

6 HTHB8*, HTHBLR*, HTHB8*, HTHB8*3, HTHBLR* HTHB8NF*, HTHBLRNF*, HTHB8NF*, HTHB8NF*3, HTHBLRNF* VERIFY CONTROL BOARD SOFTWARE ) To verify the software program of the control board the unit will need to be shut down and restarted. The chiller (if present) does not need to be shut down and restarted. ) The units lower panel must be open to access the power cord and wall outlet. 3) Shut down the unit by unplugging the power cord from the wall oulet. ) Restart the unit by plugging the power cord back into the wall outlet. 5) Upon start up the bottle count display will show the software designation of BF6, BF7, BF8 or BF9. 6) Reference the BF6BF7BF8 or BF9 instructions for setting the control board. ACCESSING THE PROGRAMING BUTON ) To access the program button the lower panel of the unit must be must be opened. The programming button is loacted at the bottom right corner of the upper panel. This area of the unit is concealed by the lower panel. RESET THE FILTER MONITOR ) Instructions apply to filtered units only. ) Depress the program button for approximately seconds until the display changes then release. The display will change and scroll through two messages: RST BCNT Reset Filter Monitor SETTINGS System Settings Sub Menu If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode. 3) When the display changes to RST FLTR, depress the button again. The display will change to show FLT =. Depress the button again and the display will show FLTR =0 ) The Green LED should be illuminated indicating that the visual filter monitor has been reset. SETTING RANGE OF THE IR SENSOR ) Depress the program button for approximately seconds until the display changes then release. The display will change and scroll through two messages: RST FLTR Reset Filter Status LED SETTINGS System Settings Sub Menu If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode. ) When the display changes to SETTINGS, depress the button again. The display will change to show RNG SET Range set for IR sensor. UNIT TYPE Type of unit (REFRIG or NONREFRIGE) RST BCNT Reset bottle count 3) When display shows RNG SET push program button once the display will show current value (can be 0) i.e. RNG = 3. ) Once display shows current value push the program button to scroll through value of 0. Select the desired range setting. 5) Once range is selected allow approximately seconds to pass and then the display will go back to bottle counter and be in run mode. 6) Test bottle filler by placing bottle or hand in front of sensor to make sure water is dispensed. BF9 PROGRM SETTING THE CONTROL BOARD SETTING UNIT TYPE ) Depress the program button for approximately seconds until the display changes then release. The display will change and scroll through two messages: RST FLTR Reset Filter Status LED SETTINGS System Settings Sub Menu If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode. ) When the display changes to SETTINGS, depress the button again. The display will change to show RNG SET Range set for IR sensor. UNIT TYPE Type of unit (REFRIG or NONREFRIGE) RST BCNT Reset bottle count 3) When display shows UNIT TYPE push program button once the display will show current value Can be REFRIG or NONREFRIG ) Push buton once to change value. Once value is selected the display will show the new value. (Can be REFRIG or NONREFRIG) REFRIG stands for refrigerated product. In this setting the flow rate is estimated at.0 gallon per minute. NONREFRIG stands for nonrefrigerated product. In this setting the flow rate is estimated at.5 gallons per minute. Both REFIG and NONREFRIG simutate bottle equal to 0 oz. 5) Allow approximately seconds to pass and the display will return to bottle counter and be in run mode. RESETTING BOTTLE COUNT ) Depress the program button for approximately seconds until the display changes then release. The display will change and scroll through two messages: RST FLTR Reset Filter Status LED SETTINGS System Settings Sub Menu If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode. ) When the display changes to SETTINGS, depress the button again. The display will change to show RNG SET Range set for IR sensor. UNIT TYPE Type of unit (REFRIG or NONREFRIGE) RST BCNT Reset bottle count If the button is not pushed again the display will scroll through the three messages above for the cycles and return to run mode. 3) When display shows RST BCNT push program button once the display will show current value i.e. BC ) Once display shows current value push the program button once more to reset back to 0. The display will show BTLCT = 0 for approximately seconds and then return to run mode showing bottles. 5) To test bottle counter, you can place bottle or hand in front of sensor for approx 5 seconds to see bottle counter count (This is based on filling a 6 oz bottle) 98558C (Rev. E 6/0) PAGE 5

7 HTHB8*, HTHBLR*, HTHB8*, HTHB8*3, HTHBLR* HTHB8NF*, HTHBLRNF*, HTHB8NF*, HTHB8NF*3, HTHBLRNF* WATERSENTRY PLUS FILTER PARTS LIST (See Fig. 8) LISTA DE PIEZAS DEL FILTRO (Vea Fig. 8) LISTE DES PIÈCES DU FILTRE (Voir Fig. 8) ITEM NO. PART NO. DESCRIPTION DESCRIPCIÓN DESCRIPTION C 7079C 7083C 708C 55898C 7088C 90C Filter Head Assy. Screw #88 x.75 PH Fitting Superseal 3/8 (0 mm) Fitting Superseal / (6 mm) Filter Assy Elbow 3/8 (0mm) Bracket Ensamblado de la Cabeza del Filtro Tornillo #88 x.75 PH Accesorio Supersello 3/8" (0mm) Accesorio Supersello /" (6 mm) Ensamblado del Filtro Codo 3/8" (0 mm) Fijador Ens. de tête de filtre Vis #88 x.75 hp Raccord Superseal 3/8" (0mm) Raccord Superseal /" (6mm) Ens. filtre Coude 3/8" (0mm) Support WATER FILTER EXPLODED VIEW FIG. 7 FIG. 8 REPLACEMENT PART KITS PART NO. 9853C 985C 9855C 9856C 9859C 9863C 9863C DESCRIPTION Kit Electrical Package Kit EE Sensor Kit Solenoid Valve Replacement Kit Aerator Replacement Kit Hardware & Waterway Parts Kit Electrical Package 0V Kit Solenoid Valve Replacement 0V CAMDEN COURT OAK BROOK, IL PRINTED IN U.S.A. FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR VISIT OUR WEBSITE PARA PIEZAS DE REEMPLAZO PÓNGASE EN CONTACTO CON SU DISTRIBUIDOR LOCAL O VISITE NUESTRO SITIO DE WEB POUR VOUS PROCURER DES PIOCES, CONTACTEZ VOTRE DISTRIBUTEUR LOCAL OU VISITEZ NOTRE SITE WEB A L ADRESSE PAGE C (Rev. E 6/0)

8 HALSEY TAYLOR OWNERS MANUAL OVL TM Series BarrierFree Water Coolers Refrigerated Fountains with Back Panel Figure OVLII ERQ Figure OVLII SRQ Figure 3 OVLII SERQ Figure OVLII ESRQ Figure 3 Model OVLII ERQ OVLII SRQ OVLII SERQ OVLII ESRQ Description OVLII Series Extended Reach OVLII Series Standard Reach OVLII Series Dual Installation OVLII Series Dual Installation INSTALLER Review these instructions before beginning installation. Be sure that installation conforms to all plumbing, electrical and other applicable codes. When installation is complete, ensure these instructions are left in the plastic bag provided inside the installed unit for future reference. Service to be performed by authorized service personnel only. NOTE: It is common practice to ground electrical hardware such as telephones, computers and other devices to available water lines. This can, however, cause electrical feedback in the plumbing circuit, which results in an electrolysis effect occurring in the fountain. This may result in water which has a metallic taste to it or has a noticeable increase in the metallic content of the water. When inspecting plumbing circuit, remember the line may be grounded some distance from the installation, and may occur outside the building or area in which the unit is being installed. This condition can be avoided (in most cases) by using recommended materials during installation. Any drain fittings provided by the installer should be made of plastic which will electronically isolate the fountain from the remainder of the building s plumbing circuits. 9788C (Rev. F 6/0)

9 /" O.D. TUBE WATER INLET TO COOLER 3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY BUILDING WATER INLET Installation Package The components for installation are packed in three separate boxes, regardless of the type of unit being installed. The boxes contain the following: NOTE: WATER FLOW DIRECTION SERVICE STOP (NOT FURNISHED) Box No. : Wall Frame(s) Box No. : Remote Chiller, SJ8Q Box No. 3: Fountain(s), Arm(s) and Panels Figure 5 Water Supply Connections Item Part No. Description 6990C Bottom Cover Standard Reach 6988C Bottom Cover Extended Reach 55836C Push Arm Actuator 5599C Push Arm Actuator A.G C Bubbler S.S. 5396C Bubbler A.G. Bubbler EasyFlex (option) 5878C Bubbler Smart Flow Bubbler Gasket Strainer Plate S.S. 500C Strainer Plate A.G Drain Gasket C Packing Ring Drain Nut Friction Ring Drain Plug S.S. 5398C Drain Plug A.G. 5683C Drain Tube 568C Drain Tube Waste Tube Gasket Slip Nut 63C Regulator C Regulator Holder C Basin S.S. 73C Basin A.G. Basin Galaxy Gray Marblyte (option) Basin Golden Sand Marblyte (option) Basin Black Onyx Marblyte (option) C Basin Liner S.S. 73C Basin Liner A.G C Screw #0 X C Top Plate Actuator C Bottom Plate Actuator 700C Extended Reach Arm S.S. 7338C Extended Reach Arm A.G. 700C Standard Reach Arm S.S. 730C Standard Reach Arm A.G. 838C Regulator Mounting Bracket C Nut Retaining 9788C (Rev. F 6/0) Additional materials, as noted in the Parts List, are also shipped in these boxes. Parts List Number Required OVLII ERQ OVLII SRQ OVLII SERQ 8 OVLII ESRQ 8 See Fig , ,6,

10 Parts List Continued Item Part No. Description NS c 7008C 70856C 7085C 5098C 5667C 8C 836C 797C 7886C 799C 7888C 6958C 7890C 795C 789C 89C 895C 896C 6833C 789C 706C 7896C 55996C 70683C 7068C 5609C 5659C 5009C 609C Hex Nut Unplated Reaction Bracket Screw #0 x.38 PHMS Rod Pivot Bushing Snap Bumper Regulator Valve Assy Arm Regulator Activating Arm Regulator Adjustment Upper Panel (OVLII ER) S.S. Upper Panel (OVLII ER) A.G. Upper Panel (OVLII SR) S.S. Upper Panel (OVLII SR) A.G. Upper Panel (OVLII SER) S.S. Upper Panel (OVLII SER) A.G. Upper Panel (OVLII ESR) S.S. Upper Panel (OVLII ESR) A.G. Upper Panel (OVLII ERGRN) S.S. Upper Panel (OVLII SERGRN) S.S. Upper Panel (OVLII ESRGRN) S.S. Lower Panel (OVLII ER/SR) S.S. Lower Panel (OVLII ER/SR) A.G. Lower Panel (OVLII SER/ESR) S.S. Lower Panel (OVLII SER/ESR) A.G. Strainer (Supplied with Chiller) Union / Tee / Poly Tubing / (Cut To Length) Bubbler Nipple Assembly Bubbler Nipple (Smart Flow ) Screen (Smart Flow Bubbler) OVLII ERQ OVLII SRQ OVLII SERQ 8 If Filtered OVLII ESRQ 8 If Filtered See Fig.,5 3, 7 3, 7 3, 7 3, 7 3, 7 3, 7 3, 7 3, 7 3, 7 3, 7 3, 7 5, 7 5, 7 5, 7 5, 7, 8 7,9,0 8,0 7,8,9,0 6 6 NOTE: S.S. means Stainless Steel A.G. means Aztec Gold NS means not shown C (Rev. F 6/0)

11 Models OVLII SERQ OVLII ESRQ. Cut a rectangular wall opening / (953 mm) W x 3/ H (959 mm) and / ( mm) above the floor line (see Figure 7). The dimensions are required to obtain proper rim and bubbler heights for compliance with ANSI standard A7... Reinforce the wall opening on all sides to adequately support the water fountain. This reinforcement must support up to 50 lbs. static load and provide a means for securing the frame assembly in place. NOTE: Building construction must allow for adequate air flow on both sides and top of remote chiller unit a minimum of (0 mm) is required. 3. Install plumbing and electrical roughins. A junction box for a (3) wire, 0 amp branch circuit is provided on the inside of the chiller. (Standard 0 Volts, 60 Hz, and single phase.) Figure 6 OVLII SERQ RoughIn. Remove frames and related hardware from packaging. Release the two shelf rods by cutting cable ties. Attach the two frames together through the upright supports with () 5/6 x 3/ (9 mm) long bolts and nuts (provided). Tighten securely. MAKE SURE FRAME CONFIGURATION MATCHES THE COOLER TO BE INSTALLED REVERSED CONFIGURATION: HIGHER UNIT ON THE RIGHT STANDARD CONFIGURATION: HIGHER UNIT ON THE LEFT Figure 7 RoughIn Assembly DualStation Mounting Frames 9788C (Rev. F 6/0)

12 5. Install the frame assembly squarely in wall opening with frame upright support edges flush with the finished wall face. Secure the frame to the wall through holes with () 5/6 bolts or screws (not provided). Tighten securely. NOTE: Be sure that frame is squared in location. Do not use less than required screw quantity and size. MODEL OVLSER SHOWN 6. Attach the chiller shelf support rods to the right side of the frame uprights at the second set of holes counting from the bottom and to the shelf at the () side holes. Line up the other shelf holes with the frame bottom holes and fasten the assembly to the wall opening using appropriately sized screws or bolts and nuts (not provided). MODEL OVLESR Legend Item A B C D Description / O.D. Tube Water Outlet Connection 3/8 O.D. Tube Water Inlet Connection / O.D. Waste Tube Electrical Inlet on Chiller Figure 8 OVLII SERQ/OVLII ESRQ RoughIn Dimensions C (Rev. F 6/0)

13 Models OVLII ERQ OVLII SRQ. Cut a rectangular wall opening 83/ (75 mm) W x 3/ H (959 mm) and / ( mm) above the floor line (see Figure 0). The dimensions are required to obtain proper rim and bubbler heights for compliance with ANSI standard A7... Reinforce the wall opening on all sides to adequately support the water fountain. This reinforcement must support up to 50 lbs. static load and provide a means for securing the frame assembly in place. NOTE: Building construction must allow for adequate air flow on both sides and top of remote chiller unit. Minimum of (0 mm) is required. 3. Install plumbing and electrical roughins. A junction box for a (3) wire, 0 amp branch circuit is provided on the inside of the chiller. (Standard 0 Volts, 60 Hz, and single phase.) Figure 9 OVLII ERQ/OVLII SRQ RoughIn. Remove frame and related hardware from packaging. Release the two shelf rods by cutting cable ties. 9788C (Rev. F 6/0) Figure 0 RoughIn Assembly SingleStation Mounting Frames 6

14 5. Install the frame squarely in wall opening with frame upright edges flush with the finished wall surface. Place shelf inside frame and line up the () holes on each. Insert loose ends of rods into holes on sides of shelf panel. Using appropriately sized screws or bolts (not provided), fasten the shelf and frame to the bottom of wall opening. Secure the frame sides and top to the wall opening using (0) 5/6 bolts or screws (not provided). NOTE: Be sure that frame is squared in location. Do not use less than the required screw quantity and size. MODEL OVLER MODEL OVLSR Legend Item A B C D Description / O.D. Tube Water Outlet Connection 3/8 O.D. Tube Water Inlet Connection / O.D. Waste Tube Electrical Inlet on Chiller Figure OVLII ERQ/SRQ RoughIn Dimensions C (Rev. F 6/0)

15 REQUIRED TOOLS AND MATERIALS These tables show special tools and/or additional materials (not provided) which are necessary to complete installation of these units: Special Tools Item Description Quantity NONE 5. Install fountain. Remove access cover plate on underside of fountains and SAVE the screws. Mount the fountains to the upper panel and frame with () 5/6 x 3/ (9mm) long bolts and nuts provided. Tighten securely. Additional Materials Item Description Quantity Unplated copper inlet pipe Service Stop OVLII ERQ/SRQ/SERQ/ESRQ INSTALLATION. Assemble and place frame in wall as shown on preceding pages.. Install chiller: Remove front panel of chiller. Remove and discard cardboard inner pack from between compressor and side panel. Slide chiller onto the shelf and position it to the left within the guides on the shelf. NOTE: Building construction must allow for adequate air flow on both sides, top and back of chiller. A minimum of (0mm) on both sides and top is required. See chiller installation for additional instructions. Figure 3 Upper Panel Installation Note: With OVLII SERQ or OVLII ESRQ models, the standard reach fountain must be mounted at the upper position on panel. Figure Chiller Installation 3. Make water supply connections. Inlet port is marked on the chiller (/ O.D. copper tube). Bend the copper tube (provided) at an appropriate length from the chiller to opening in frame. Install the inline strainer (provided with chiller) by pushing it in until it reaches a positive stop, approximately 3/ (9mm) on the marked chiller inlet port. Attach an unplated and deburred copper water inlet line and a service stop (not provided) to the chiller. Turn on the water supply and flush the line thoroughly.. Hang the upper panel on the mounting frame hanger. Align holes in the panel with the holes in the mounting frame. Be sure that panel is engaged with hanger at top of frame before releasing it. 9788C (Rev. F 6/0) 8 Figure Fountain Installation 6. Connect the fountain drain waste tube to the building sanitary sewer system. Connection should be made in compliance with local plumbing code requirements. (Note: Plumbing trap is not included with the fountain). 7. Make connection between remote chiller outlet tube and fountain(s). Outlet port is marked on the chiller (/ O.D. copper tube). Install a / union/tee (provided) on the marked chiller outlet port. Insert the / poly tubing coming from the fountain(s) into the union/tee. Turn on water supply and check for leaks.

16 DO NOT SOLDER tubes while inserted into the strainer as damage to orings may result. 8. These products are designed to operate on 005 PSIG supply line pressure. If inlet pressure is above 05 PSIG, a pressure regulator must be installed in the supply line. Any damage caused by connecting these products to a supply line with pressure lower than 0 PSIG or higher than 05 PSIG IS NOT covered under warranty. 9. Make electrical connections to the chiller. See chiller instructions. 0. Check stream height from bubbler. Stream height is factory set at 350 PSI. If supply pressure varies greatly from this, remove items, 9, and 0 (push arm and the bottom and the top actuator plates Figure 0) by removing the screws holding assembly together and adjust the screw on the regulator (Item Figs. & ). Clockwise adjustment will raise stream height and counterclockwise movement will lower stream height. For best adjustment, stream height should be approximately / (38mm) above the bubbler guard. (See Figure 6).. Mount lower panel. Loosen the two () #0 x 5/8 (6mm) screws at frame bottom lip. Slide upper tongue of lower panel under lower edge of already installed upper panel. Tighten previously loosened screws securely.. Replace bottom access panel to fountain basin using screws provided. Tighten securely. TO BUBBLER 35 CHILLER OUTLET Figure 6 Stream Height 3 Figure 7 OVLII ERQ/SRQ Tube Routing CHILLER INLET TO BUBBLER 36 CHILLER OUTLET 3 CHILLER INLET Figure 5 Lower Panel Installation Figure 8 OVLII SERQ/ESRQ Tube Routing C (Rev. F 6/0)

17 TO BUBBLER 35 CHILLER OUTLET 35 WATER INLET. Install chiller: Remove front panel of chiller. Remove and discard cardboard inner pack from between compressor and side panel. Slide chiller onto the shelf and position it to the left as per dimensions in Figure. Note: Building construction must allow for adequate air flow on both sides, top and back of chiller. A minimum of (0mm) on both sides and top is required. See chiller installation for additional instructions.. Make water supply connections. Install a shutoff valve and union connection to building water supply (valve and union not provided). Turn on water supply and flush the line thoroughly. TO BUBBLER OVLERQGRN Tube Routing Figure 9 3. OVLERQGRN: Make connection between remote chiller and building supply line. Inlet port is marked on the chiller (/ O.D. copper tube). Bend the copper tube (provided) at an appropriate length from chiller to opening in frame. Install the inline strainer (provided with chiller) by pushing it until it reaches a positive stop, approximately 3/ (9mm) on the marked chiller inlet port. Connect building supply line to strainer. (See Figure 9) 36 CHILLER OUTLET 35 WATER INLET Caution: DO NOT SOLDER tubes inserted into the strainer as damage to orings may result.. OVLSERQGRN & OVLESRQGRN: Mount filter head assembly to side of chiller (See Figure 0). Make connections between filter and building supply line (3/8 O.D. tube not provided). Inlet port is marked on the chiller (/ O. D. copper tube). Install a / x / union (provided) on the marked chiller inlet port. Insert the / poly tubing (provided) into the fitting on filter and connect the union to the chiller. (See Figure 0) OVLSERQGRN / OVLESRQGRN Tube Routing Figure 0 Caution: DO NOT SOLDER tubes inserted into the strainer as damage to orings may result. 7 When provided 3 6 WATERSENTRY FILTER PARTS LIST (See Fig. ) ITEM NO. PART NO. DESCRIPTION C 7079C 7083C 708C 55897C 7088C 90C Filter Head Assy. Screw #88 x.75 PH Fitting Superseal 3/8 (0 mm) Fitting Superseal / (6 mm) Filter Assy Elbow 3/8 (0mm) Bracket Water Filter Detail Figure 9788C (Rev. F 6/0) 0

18 TROUBLESHOOTING & MAINTENANCE Orifice Assembly: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice by poking with a small round file not over /8 diameter, or using a small diameter wire. DO NOT file or cut orifice material. Stream Regulator: If orifice is clean, regulate flow as in Step 0 of the installation instructions. If replacement is necessary, see parts list for correct regulator part number. To preserve the quality and keep this AZTEC GOLD finish clean and spot free, clean this surface with only mild detergent or window cleaner and polish with a soft cloth. DO NOT use any abrasive cleaners or harsh chemicals. They WILL damage the finish! Figure 3 Push Arm Mechanism Actuation of Quick Connect Water Fittings: Cooler is provided with leadfree connectors which utilize an oring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing. (See Figure ) To insert tubing, push tube straight into fitting until it reaches a positive stop (approximately 3/ ) Figure Quick Connect Fittings Stream Height Adjustment 7 5 Figure Regulator Mounting Mechanism 9788C (Rev. F 6/0)

19 REGULATOR MOUNTING BRACKET 39 Figure 5 Regulator Assembly Fig. 6 Smart Flow Bubbler Detail 3 6 3, See Fig. 7 See Fig See Fig CAMDEN COURT OAK BROOK, IL Figure 7 Fountain Assembly Side View FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR VISIT OUR WEBSITE C (Rev. F 6/0)

Installation/Care/Use Manual EZH20 In Wall Bottle Filling Station

Installation/Care/Use Manual EZH20 In Wall Bottle Filling Station Installation/Care/Use Manual EZH20 In Wall Bottle Filling Station LZWSM8* LZWSMD* LZWSM8P* LZWSMDP* EZWSM8* EZWSMD* EZWSM8P* EZWSMDP* Installer To assure you install this model easily and correctly, PLEASE

More information

Halsey Taylor Owners Manual

Halsey Taylor Owners Manual Halsey Taylor Owners Manual OVL Fountains with Dual Stream Bubbler and HydroBoost Bottle Filler INSTALLER Review these instructions before beginning installation. Be sure that installation conforms to

More information

Installation/Care/Use Manual EZH20 In Wall Bottle Filling Station

Installation/Care/Use Manual EZH20 In Wall Bottle Filling Station Installation/Care/Use Manual EZH20 In Wall Bottle Filling Station LZWSM8* LZWSMD* LZWSM8P* LZWSMDP* EZWSM8* EZWSMD* EZWSM8P* EZWSMDP* Installer To assure you install this model easily and correctly, PLEASE

More information

Installation and Use Manual

Installation and Use Manual Installation and Use Manual HTHB-HAC Retrofit Hydroboost Bottle Filling Station IMPORTANT THIS IS AN INDOOR APPLICATION ONLY. ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON. TOOLS REQUIRED

More information

LZWSRK -EZH2O IMPORTANT

LZWSRK -EZH2O IMPORTANT INSTALLATION, CARE & USE MANUAL LZWSRK -EZH2O TM RETRO-FIT BOTTLE FILLING UNIT IMPORTANT THIS IS AN INDOOR APPLICATION ONLY. ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON. TOOLS REQUIRED

More information

Installation and Use Manual

Installation and Use Manual Installation and Use Manual EMABFWS-RF and LMABFWS-RF Retrofit Bottle Filling Stations IMPORTANT THIS IS AN INDOOR APPLICATION ONLY. ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON. TOOLS REQUIRED

More information

INSTALLATION, CARE & USE MANUAL

INSTALLATION, CARE & USE MANUAL INSTALLATION, CARE & USE MANUAL LVRC8WS, LVRC8WSJO, LVRCTL8WS, LVRCTL8WSJO, Factory Prep EZH2O Bottle Filling Station and Cooler Model LVRC8WS IMPORTANT THIS IS AN INDOOR APPLICATION ONLY. ALL SERVICE

More information

LZWSRK -EZH2O IMPORTANT

LZWSRK -EZH2O IMPORTANT INSTALLATION, CARE & USE MANUAL LZWSRK -EZH2O TM RETRO-FIT BOTTLE FILLING UNIT IMPORTANT THIS IS AN INDOOR APPLICATION ONLY. ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON. TOOLS REQUIRED

More information

Installation/Care/Use Manual

Installation/Care/Use Manual Installation/Care/Use Manual EMABFWS-RF LMABFWS-RF Retrofit Bottle Filling Station IMPORTANT THIS IS AN INDOOR APPLICATION ONLY. ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON. TOOLS REQUIRED

More information

INSTALLATION and USE MANUAL Models (L)VRC8WS, (L)VRC8WSJO Factory Prep ezh2o Bottle Filling Station and Cooler

INSTALLATION and USE MANUAL Models (L)VRC8WS, (L)VRC8WSJO Factory Prep ezh2o Bottle Filling Station and Cooler INSTALLATION and USE MANUAL Models (L)VRC8WS, (L)VRC8WSJO Factory Prep ezh2o Bottle Filling Station and Cooler IMPORTANT THIS IS AN INDOOR APPLICATION ONLY. ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED

More information

EZ & LZ Series Bottle Filling Stations & Coolers

EZ & LZ Series Bottle Filling Stations & Coolers ITALLATION, CARE & USE MANUAL TM TM EZ & LZ Series Bottle Filling Stations & Coolers Page 000005 (Rev. B - 0/6) Note: Danger! Electric shock hazard. Disconnect power before servicing unit. Uses HFC-4A

More information

Installation/Care/Use Manual

Installation/Care/Use Manual Installation/Care/Use Manual EZH20 Surface Mount Bottle Filling Station IMPORTANT THIS IS AN INOOR APPLICATION ONLY! ALL SERVICE TO BE PERFORME BY AN AUTHORIZE SERVICE PERSONNEL. TOOLS/ITEMS REQUIRE BUT

More information

EZWSRK -EZH2O IMPORTANT

EZWSRK -EZH2O IMPORTANT INSTALLATION, CARE & USE MANUAL EZWSRK -EZH2O TM RETRO-FIT BOTTLE FILLING UNIT IMPORTANT THIS IS AN INDOOR APPLICATION ONLY. ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON. TOOLS REQUIRED

More information

EZWSRK -EZH2O LZWSRK -EZH2O

EZWSRK -EZH2O LZWSRK -EZH2O INSTALLATION, CARE & USE MANUAL EZWSRK -EZ2O LZWSRK -EZ2O TM TM RETRO-FIT BOTTLE FILLING UNIT RETRO-FIT BOTTLE FILLING UNIT IMPORTANT TIS IS AN INDOOR APPLICATION ONLY. ALL SERVICE TO BE PERFORMED BY AN

More information

Cooler Mounted Bottle Fillers

Cooler Mounted Bottle Fillers BF Series Bottle Filler, Sensor Operated TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:.800.9.960 Technical Assistance Fax:.66.8.89 NOTES TO INSTALLER:. Please leave this documentation with the owner

More information

Series Barrier-Free Water Coolers

Series Barrier-Free Water Coolers INSTALLATION, CARE & USE MANUAL VRC TM Series Barrier-Free Water Coolers 0 20 Uses HFC-34A refrigerant 38, 39 54 6, 7, 22, 4 5 50 42 59, 60 23, 6, 62 42 6, 4 25 See Fig. 4 See Fig. 3 24, 30 43 8 33 49

More information

Series Barrier-Free Water Coolers

Series Barrier-Free Water Coolers INSTALLATION, CARE & USE MANUAL VRC TM Series Barrier-Free Water Coolers 10 Uses HFC-134A refrigerant 20 54 43 38, 39 7, 22, 41 6 51 42 23, 30 14, 17, 18 42 16 1, 4 25 50 24 See Fig. 4 See Fig. 3 8 19

More information

Model H1011.8/H1011.8HPS Water Cooler

Model H1011.8/H1011.8HPS Water Cooler 455 Kleppe Lane Sparks, NV 8943-6467 (775) 359-472 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model H0.8/H0.8HPS Water Cooler INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

More information

A112408B/S-VR-UBL TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: Technical Assistance Fax:

A112408B/S-VR-UBL TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: Technical Assistance Fax: INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Vandal Resistant Refrigerated Universal Bi-Level AquaAccess Barrier Free, Wall Mounted Water Cooler OR Alternate Configuration A112408B/S-VR-UBL TECHNICAL

More information

MODEL 6430T, 6460 & 6460T POTATO PEELER

MODEL 6430T, 6460 & 6460T POTATO PEELER MODEL 6430T, 6460 & 6460T POTATO PEELER MODEL ML-137602 6430T ML-19630 6460 ML-137604 6460T ML-104562 6460C ML-137606 6460CT 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 37005 (Apr. 2006) Installation,

More information

Cooler Mounted Bottle Fillers

Cooler Mounted Bottle Fillers BF & BF Bottle Filler Series Pushbutton Actuated Sensor Operated BF BF Please visit www.murdockmfg.com for most current specifications. TABLE OF CONTENTS Dimensional Data/Rough-Ins................................................

More information

HID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service

HID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service HID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service What you will learn Introduction Installation Operation Maintenance Take It Apart Diagnostics HID Ice Maker-Dispensers HID models

More information

INSTALLATION, CARE & USE MANUAL VRC8WS, VRC8WSJO, VRCTL8WS, VRCTLR8WS Factory Prep EZH2O Bottle Filling Station and Cooler

INSTALLATION, CARE & USE MANUAL VRC8WS, VRC8WSJO, VRCTL8WS, VRCTLR8WS Factory Prep EZH2O Bottle Filling Station and Cooler INSTALLATION, CAR & US MANUAL VRC8WS, VRC8WSJO, VRCTL8WS, VRCTLR8WS Factory Prep ZH2O Bottle Filling Station and Cooler Model VRC8WS IMPORTANT THIS IS AN INDOOR/OUTDOOR APPLICATION. ALL SRVIC TO B PRFORMD

More information

A152.8 Series Barrier Free, Bi-Level, Wall Mounted Drinking Fountain

A152.8 Series Barrier Free, Bi-Level, Wall Mounted Drinking Fountain Series Barrier Free, Bi-Level, Wall Mounted Drinking Fountain A52408S / A52408S-SO TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:.800.59.9360 Technical Assistance Fax:.626.855.4894 NOTES TO INSTALLER:.

More information

Installation & Operation Manual

Installation & Operation Manual Installation & Operation Manual Adjustable Push Button and Battery Operated Infrared CWBF-1 Table of Contents Pre-Installation Information...2 Standard Bottle Filler Configurations...3 Physical Dimensions...4

More information

Water Runs Continuously out of the Bubbler. Water Quality Problem (taste and odor) Water Flow is Intermittent or Erratic

Water Runs Continuously out of the Bubbler. Water Quality Problem (taste and odor) Water Flow is Intermittent or Erratic No Water Flow out of Bubbler No water flow No power to outlet Confirm cooler is plugged into electrical outlet. Check if circuit ***No water flow from bubbler on products with a refrigeration system. Water

More information

VERSAFILLER Model PWEBF (retro fit) and P*EBF Family of Drinking Fountains/VersaFiller. combo Installation Instructions

VERSAFILLER Model PWEBF (retro fit) and P*EBF Family of Drinking Fountains/VersaFiller. combo Installation Instructions VERSAFILLER Model PWEBF (retro fit) and P*EBF Family of Drinking Fountains/VersaFiller combo Installation Instructions The Hands-Free VersaFiller is an extension of the Aqua Pointe product line that mounts

More information

VERSAFILLER Model PWSBF (retro fit) and P*SBF Family of Drinking Fountains/VersaFiller. combo Installation Instructions

VERSAFILLER Model PWSBF (retro fit) and P*SBF Family of Drinking Fountains/VersaFiller. combo Installation Instructions VERSAFILLER Model PWSBF (retro fit) and P*SBF Family of Drinking Fountains/VersaFiller combo Installation Instructions The VersaFiller is an extension of the Aqua Pointe product line that mounts directly

More information

A132.8 Series Barrier Free, Wall Mounted Electric Drinking Fountain

A132.8 Series Barrier Free, Wall Mounted Electric Drinking Fountain Series Barrier Free, Wall Mounted Electric Drinking Fountain ** U.S. DESIGN PATENT D545,607 (Bowl Design) A12408S / A12408S-SO TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 1.800.591.960 Technical Assistance

More information

52 Lacey LED. Instruction Manual. 6 Speed DC Wall Control System

52 Lacey LED. Instruction Manual. 6 Speed DC Wall Control System 6 Speed DC Wall Control System 52 Lacey LED HIGH EFFICIENCY DC MOTOR Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Customer Service 866.558.5706 8:30 AM to

More information

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Refrigerated Bi-Level, Sensor Operated, AquaAccess Barrier Free, Wall Mounted Water Cooler

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Refrigerated Bi-Level, Sensor Operated, AquaAccess Barrier Free, Wall Mounted Water Cooler INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Refrigerated Bi-Level, Sensor Operated, AquaAccess Barrier Free, Wall Mounted Water Cooler A112108F-SO / A112108B-SO / A112408F-SO / A112408B-SO TECHNICAL

More information

OUTDOOR DRINKING FOUNTAINS OPERATIONS MANUAL

OUTDOOR DRINKING FOUNTAINS OPERATIONS MANUAL OUTDOOR DRINKING FOUNTAINS OPERATIONS MANUAL Installation & Operation Manual Stainless Steel Series One-, Two-, and Three-station Outdoor Drinking Fountains MADE IN THE U.S.A. Table of Contents Pre-Installation

More information

A172108F-UBL / A172408F-UBL / A172108F-SO / A172408F-SO TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

A172108F-UBL / A172408F-UBL / A172108F-SO / A172408F-SO TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: Series Refrigerated Universal Bi-Level Barrier Free, Wall Mounted Water Cooler OR Alternate Configuration Standard Configuration A172108F-UBL / A172408F-UBL / A172108F-SO / A172408F-SO TECHNICAL ASSISTANCE

More information

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades. 1 1. SAFETY RULES 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning. 2. All wiring must be in accordance with the National

More information

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: Remote Water Chiller, 8 GPH A9100080-A / A9100080-A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 1.800.591.9360 Technical Assistance Fax: 1.626.855.4894 NOTES TO INSTALLER: 1. Please leave this

More information

Installation Guide BI-98 Ice Maker www.u-lineservice.com Phone (414) 354-0300 FAX (414) 354-7905 Service & Parts Tech Lines Phone (800) 779-2547 FAX (414) 354-5696 OnlineService@U-Line.com 2005 U-Line

More information

Installation Instructions 36 Inch Refrigerator

Installation Instructions 36 Inch Refrigerator Installation Instructions 36 Inch Refrigerator For Use With Models: EF36BNNF, IF36BNNF, PF36BNNF Francis - Voir Page 9 Part No. 106177 Rev. B/13036906 Refrigerator Safety...1 Proper Disposal of Your Refrigerator...1

More information

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Sensor Operated AquaAccess Barrier Free, Wall Mounted Water Cooler

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Sensor Operated AquaAccess Barrier Free, Wall Mounted Water Cooler INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Sensor Operated AquaAccess Barrier Free, Wall Mounted Water Cooler A111108F-SO / A111108B-SO / A111408F-SO / A111408B-SO TECHNICAL ASSISTANCE TOLL FREE

More information

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL CEILING FAN OWNER'S MANUAL READ AND SAVE THESE INSTRUCTIONS MODEL: 52-135-5WA-13 FAN RATING AC 120V. 60Hz CUL LISTED MODEL : AC-552OD 1. TOOLS AND MATERIALS REQUIRED Philips screw driver Blade screw driver

More information

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. Irene 52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. 60Hz TABLE OF CONTENTS Tools and Materials Required... 1 Package Contents... 1 Safety Rules... 2 Mounting Options... 3 Hanging

More information

installation and operation manual for Hunter Ceiling Fans

installation and operation manual for Hunter Ceiling Fans For Your Records and Warranty Assistance Model Name: Catalog/Model No.: Serial No.: Date Purchased: Where Purchased: For reference also attach your receipt or a copy of your receipt to the manual. installation

More information

60" Hatteras BayTM. Patio. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

60 Hatteras BayTM. Patio. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan Includes our new Wall Control System 60" Hatteras BayTM Patio A Kichler Décor ceiling fan Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Customer Service 866.558.5706

More information

FOR PRODUCT/WARRANTY REGISTRATION Go to Click on SUPPORT at the top of homepage Click on PRODUCT REGISTRATION

FOR PRODUCT/WARRANTY REGISTRATION Go to   Click on SUPPORT at the top of homepage Click on PRODUCT REGISTRATION Salvajor Commercial Disposers For All Models: 75, 00, 50, 200, 300, 500, 750 Models 75-200 Models 300-750 2 Typical Installations & Installation of Cone Bowl or Sink Collar 3 Attaching Disposer to Cone

More information

Undercounter Refrigeration

Undercounter Refrigeration INSTALLATION GUIDE Undercounter Refrigeration Contents Undercounter Refrigeration..................... 3 Undercounter Specifications.................... 4 Site Preparation..............................

More information

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL CEILING FAN OWNER'S MANUAL MODEL: Pelham HVFC# 2299 Old Bronze Satin Nickel Polished Nickel READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. 60Hz. CUL LISTED MODEL: AC-554SY05-7S WEIGHT OF THE FAN:

More information

LIVIN THE DOG LIFE DRINKING FOUNTAINS INSTALLATION & OPERATION MANUAL

LIVIN THE DOG LIFE DRINKING FOUNTAINS INSTALLATION & OPERATION MANUAL LIVIN THE DOG LIFE TM DRINKING FOUNTAINS INSTALLATION & OPERATION MANUAL Installation & Operation Manual Stainless Steel Series One-, Two-, and Three-station Outdoor Drinking Fountains MADE IN THE U.S.A.

More information

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S. Patent Pending Orrin A Kichler Select ceiling fan Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010

More information

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL A171.8 Series Barrier Free, Wall Mounted Water Cooler

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL A171.8 Series Barrier Free, Wall Mounted Water Cooler INSTALLATION, OPERATIONS & MAINTENANCE MANUAL A171.8 Series Barrier Free, Wall Mounted Water Cooler MERIDIAN 3791 A171108F / A171408F / A171108F-SO / A17408F-SO TECHNICAL ASSISTANCE TOLL FREE TELEPHONE

More information

Installation & Operation Manual

Installation & Operation Manual Installation & Operation Manual Outdoor Bottle Fillers Table of Contents Pre-Installation Information...2 Physical Dimensions...4 Rough-In Dimensions...5 Hardware Identification Chart...6 Installation

More information

CircoloTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

CircoloTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection. CircoloTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S. Patent

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS BUILT-IN BOTTOM MOUNT REFRIGERATOR/FREEZER DBRTGK72SS-GRILLE KIT (FOR designer SERIES ONLY) VIKING RANGE CORPORATION 111 Front Street Greenwood, Mississippi (MS) 38930 USA (662)

More information

Installation Instructions for. OmniFount

Installation Instructions for. OmniFount Installation Instructions for OmniFount Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when properly installed and

More information

KimberleyTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

KimberleyTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection. KimberleyTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S. Patent

More information

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades. 1 1. SAFETY RULES 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning. 2. All wiring must be in accordance with the National

More information

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. 60Hz Please do not use any electric or battery powered tools in the assembly and installation of this or any Matthews Fan Company

More information

SS1095 Ice Maker.

SS1095 Ice Maker. Installation Guide SS1095 Ice Maker www.u-lineservice.com Phone (414) 354-0300 FAX (414) 354-7905 Service & Parts Tech Lines Phone (800) 779-2547 FAX (414) 354-5696 OnlineService@U-Line.com 2008 U-Line

More information

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels Installation Instructions For the 18 Built-In Dishwasher and Front Color Panels Printed in USA 154232102 Before You Begin DO NOT INSTALL DISHWASHER UNTIL YOU HAVE READ ALL INSTRUCTIONS. FOR YOUR SAFETY,

More information

52 DorsetTM. Instruction Manual. Basic Function Wall Control System Included. A Kichler Decor ceiling fan

52 DorsetTM. Instruction Manual. Basic Function Wall Control System Included. A Kichler Decor ceiling fan Basic Function Wall Control System Included 52 DorsetTM II A Kichler Decor ceiling fan Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Customer Service 866.558.5706

More information

Installation & Operation Manual

Installation & Operation Manual Installation & Operation Manual Table of Contents Pre-Installation Information...2 Physical Dimensions...4 Rough-In Dimensions...5 Hardware Identification Chart...6 Installation Instructions...7 Step 1:

More information

Installation. Built-in Full Height Wine Cellar VCWB301

Installation. Built-in Full Height Wine Cellar VCWB301 Installation Built-in Full Height Wine Cellar VCWB301 Table of Contents Warnings & Important Information _ 3 Dimensions _ 5 Specifications _ 6 Cutout Dimensions 7 Cabinet Information _ 8 Cabinet Information

More information

Water Boilers ME10EN, ME15EN. Table of Contents

Water Boilers ME10EN, ME15EN. Table of Contents Water Boilers ME10EN, ME15EN Operator Manual Model ME15EN Model ME10EN Safety Information...2 Rough-In Drawing...3 Installation...4 Priming...5 Cleaning...5 Table of Contents Adjustments...6 Maintenance...7

More information

Owner s Guide and Installation Manual

Owner s Guide and Installation Manual For Your Records and Warranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. Model Name Type 8 Models Owner s Guide and Installation Manual Model No. Catalog

More information

Installation and Operation Manual MG-304. Please read this manual carefully before use.

Installation and Operation Manual MG-304. Please read this manual carefully before use. Installation and Operation Manual MG-304 Please read this manual carefully before use. 1 P a g e Important Safety Instructions: Warning! Use this unit only for its intended purposes or as described in

More information

BLAST-IT-ALL BUMPER BLASTER

BLAST-IT-ALL BUMPER BLASTER LARRY HESS AND ASSOCIATES, INC 185 PIPER LANE / SALISBURY, NC 28147 PHONE: 1-800-535-2612 / FAX: 1-704-638-9311 WWW.BLAST-IT-ALL.COM BLAST-IT-ALL BUMPER BLASTER SUCTION BLAST CABINET NOTE: It is the responsibility

More information

B.I.C.A Built-In Coffee Appliance

B.I.C.A Built-In Coffee Appliance B.I.C.A Built-In Coffee Appliance Automatic Coffee Brewer Parts & Service Models: 1033510, 1033510S & 1033511 3828 S. Main St. Los Angeles, CA 90037-1491 800-421-6860 310-787-5444 Fax 310-787-5412 e-mail:

More information

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999 TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO. 8801469 EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999 THE MILK COOLING SYSTEMS SPECIALISTS TM FRE-HEATER Part No. 8801469 Table

More information

SCN60 Residential Nugget Ice Machine

SCN60 Residential Nugget Ice Machine SCN60 Residential Nugget Ice Machine SCN60 Nugget Ice Nugget Ice What it isn t: Ice frozen in a mold What it is: A chewable ice, formed continuously by forcing soft ice thru tapered holes. Components Compared

More information

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE COVE DISHWASHER Contents 3 Cove Dishwasher 4 Specifications 7 Door Panel 9 Installation 15 Troubleshooting Features and specifications

More information

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis Installation And Service Manual Watts Pure Water 1725 W. Williams Dr. C-20., Phoenix, Arizona 85027 Phone: 888-774-7405 Fax: 602-588-0356 www.wattspurewater.com

More information

CORALAIS BODYSPA BATH AND SHOWER FAUCET

CORALAIS BODYSPA BATH AND SHOWER FAUCET CORALAIS BODYSPA BATH AND SHOWER FAUCET 1. BEFORE YOU BEGIN HOW TO USE THESE INSTRUCTIONS Please read these instructions carefully to familiarize yourself with the required tools, materials, and installation

More information

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL CEILING FAN OWNER'S MANUAL READ AND SAVE THESE INSTRUCTIONS MODEL: 52-854-5RV-234 52-854-5RV-CH 52-854-5RV- FAN RATING AC 120V. 60Hz CUL LISTED MODEL : AG-962MC 1. TOOLS AND MATERIALS REQUIRED Philips

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS CEILING FAN INSTALLATION AND OPERATION INSTRUCTION FAN RATING AC 120V. 60Hz UL LISTED MODEL: AC-552OD WEIGHT OF FAN: 6.82 KGS 1. TOOLS AND MATERIALS REQUIRED Philips screw

More information

ValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

ValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S. ValkyrieTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you

More information

Owner's Manual. WS Series. Water Softener

Owner's Manual. WS Series. Water Softener Owner's Manual WS-165-150 Series Water Softener Table of Contents WHAT'S INCLUDED 3 OPERATING CONDITIONS 4 ASSEMBLY INSTRUCTIONS 6 FLUSHING THE WATER LINES 13 MASTERPROGRAMMING 14 PROGRAMMING KEYAND GENERAL

More information

Remote Water Quality System Standard Equipment (supplied by EPI) Remote Water Quality System Optional Equipment (supplied by EPI)

Remote Water Quality System Standard Equipment (supplied by EPI) Remote Water Quality System Optional Equipment (supplied by EPI) Page 1 of 11 Parts List Remote Water Quality System Standard Equipment (supplied by EPI) 20sq ft Skimmer-Filter Remote Water Quality Plumbing Kit Heater-Controller Keypad Control 220V 3/4HP Circulation

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide Viking Range, LLC 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-(845-4641) or visit the Viking Web site at vikingrange.com

More information

Helpful Tip: NOTE:

Helpful Tip: NOTE: Grounded electrical supply required. Do not run drain lines, water lines or electrical wiring where they can interfere with or contact dishwasher motor or legs. The location where the dishwasher will be

More information

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL Distinctive Lighting and Ceiling Fans CEILING FAN OWNER'S MANUAL MODEL: 52CW2L5-GM 52CW2L5-OBB READ AND SAVE THESE INSTRUCTIONS FOR CEILING FAN PARTS AND SERVICE, CALL 1-877-902-5588 FAN RATING AC 120V.

More information

ChicagoTM. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

ChicagoTM. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S. Patent Pending ChicagoTM A Kichler Decor ceiling fan Kichler Lighting 7711 East Pleasant Valley Road P.O. Box

More information

Installation & Operating Guide

Installation & Operating Guide 5-036 HOT WATER TANK Installation & Operating Guide Read all instructions thoroughly. Keep this guide for future reference. Proof of purchase is required for Warranty. Staple receipt or proof of purchase

More information

60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

60 Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan 60" Lyndon Patio TM 310140 A Kichler Decor ceiling fan Includes wall mount control system Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Instruction Manual Customer

More information

Advanced Two-Stage Drinking Water Filter

Advanced Two-Stage Drinking Water Filter OWNER'S MANUAL E L I T E Advanced Two-Stage Drinking Water Filter MODEL NO. 625.385010 Caution: Read and follow all safety rules and operating instructions before first use of this product. Questions?

More information

Installation Manual PS-225 & PS-275

Installation Manual PS-225 & PS-275 Installation Manual PS-225 & PS-275 Table of Contents Pre-Uncrating Checklist... 1 Verifying System Requirements... 2 Verifying System Direction... 2 Verifying the Electrical Requirements... 2 Removal

More information

A171.8 Series Barrier Free, Wall Mounted Water Cooler

A171.8 Series Barrier Free, Wall Mounted Water Cooler Series Barrier Free, Wall Mounted Water Cooler A171108F / A171408F / A171108S / A17408S TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 1.800.591.9360 Technical Assistance Fax: 1.626.855.4894 NOTES TO

More information

EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS

EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS 0.0 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation

More information

Select. Sutter PlaceTM. Instruction Manual. A Kichler Select ceiling fan

Select. Sutter PlaceTM. Instruction Manual. A Kichler Select ceiling fan Sutter PlaceTM A Kichler ceiling fan Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Customer Service 866.558.5706 8:30 AM to 5:00 PM EST, Monday - Friday Instruction

More information

Hanson LED C e i l i n g F a n

Hanson LED C e i l i n g F a n Hanson LED C e i l i n g F a n model no. 052-8398-2 Toll-free 1-866-827-4985 IMPORTANT: For your safety please read and understand this manual before installing or operating this product. OWNER S MANUAL

More information

INSTALLATION. Glass Panel Doors (select models) CAUTION

INSTALLATION. Glass Panel Doors (select models) CAUTION Location Do not install refrigerator near oven, radiator or other heat source. If not possible, shield refrigerator with cabinet material. Do not install where temperature falls below 55 F (13 C) or rises

More information

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio 42 Kevlar Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Customer Service 866.558.5706 8:30 AM to 5:00 PM EST, Monday - Friday Instruction Manual 1 1. SAFETY

More information

Sunburst. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

Sunburst. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan Includes our new Wall Control System Sunburst A Kichler Décor ceiling fan Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Customer Service 866.558.5706 8:30 AM

More information

475 PRO SERIES Reverse Osmosis System Installation & Operation Manual

475 PRO SERIES Reverse Osmosis System Installation & Operation Manual PLEASE READ ALL INSTRUCTIONS BEFORE INSTALLING AND USING THIS SYSTEM 475 PRO SERIES Reverse Osmosis System Installation & Operation Manual Model STAGE 1 STAGE 2 STAGE 3 STAGE 4 OUTPUT 475 SEDIMENT CARBON

More information

Owner s Guide and Installation Manual

Owner s Guide and Installation Manual For Your Records and Warranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. Model Name Type 2 Models Owner s Guide and Installation Manual Model No. Date Purchased

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 67000 6700 MODEL: SPRITZ 67000 (RH-600) 6700 (RH-600X) REV.C Restoration Hardware Faucet Product Size Specification Diagram Recommended Deck Hole Size -/8 Diameter Dimensions

More information

PRO 48 INSTALLATION INSTRUCTIONS

PRO 48 INSTALLATION INSTRUCTIONS PRO 48 INSTALLATION INSTRUCTIONS CONTENTS PRO 48 Installation Recommendations 3 PRO 48 Overall Dimensions 4 PRO 48 Installation Specifications 5 PRO 48 Installation Instructions 6 PRO 48 Installation Checklist

More information

54" Skye. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

54 Skye. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan 54" Skye TM 300167 A Kichler Decor ceiling fan Includes wall mount control system Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Instruction Manual Customer

More information

Installation Manual PS-200 & PS-201

Installation Manual PS-200 & PS-201 Installation Manual PS-200 & PS-201 Table of Contents Pre-Uncrating Checklist... 1 Verifying System Requirements... 2 Verifying System Direction... 2 Verifying the Electrical Requirements... 2 Removal

More information

IJ3000 IJ3000 Flushing System N Revision B Installation Instructions Page 1 of 10

IJ3000 IJ3000 Flushing System N Revision B Installation Instructions Page 1 of 10 IJ3000 IJ3000 Flushing System 5760-029N Revision B Installation Instructions Page 1 of 10!! WARNING: Do not turn on until all plumbing and electrical connections have been made. WARNING: The flushing system

More information

FitchTM. Instruction Manual. Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go!

FitchTM. Instruction Manual. Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go! Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go! FitchTM A Kichler Décor ceiling fan U.S. Patent Pending Kichler Lighting 7711 East Pleasant Valley Road

More information

Highland ManorTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

Highland ManorTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection. Highland ManorTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

More information