GRIMM Aerosol Technik

Size: px
Start display at page:

Download "GRIMM Aerosol Technik"

Transcription

1 GRIMM Aerosol Technik Existing technologies and improvements Environmental Measurement Instruments by Eng. Wolfgang Brunnhuber General features Mobile Systems Stationary Systems WRAS Systems MAIN FEATURES ENVIRONMENTAL * 31 channel size distribution * Different measurements simultaneously * No probe heating only dehuminifiaction * No loss of Semi-Volatile compounds * Chemical specification possible #107 Portable Dust Monitor with glas bottle and filter with PTFE Filter chamber #165 Weather Housing * Includes #107 * Fiber glas case * 47mm PTFE Filter Small and portable solution for dust measurment in outdoor areas 1

2 #165 main parts DEHUMIDIFICATION EDM165 Humidity Temperature Sensor Sample Pipe Dryer Operating Principle Reserve Monitor #365 Mobile Dust Monitor Grimm Photo von Environment Canada, Ontario * Stainless steal housing * Long term measurement * 47mm PTFE Filter possible #180 stationary ambient monitor Stationary Systems EN12341 certified * Certified for PM10 according to EN12341 * 19zoll rack mount * Special NAFION dehumidification system * GESYTEC MODE for networks * Long time measurement * Very low TCO s 2

3 Sampling pipe with Nafion tube Nafion - The Perfect Drying Material Nafion is a copolymer of tetrafluoroethylene (Teflon ). Like Teflon, Nafion is highly resistant to chemical attack, but the presence of its exposed sulfonic acid groups confers unusual properties. Sulfonic acid has a very high water-of-hydration, absorbing 13 molecules of water for every sulfonic acid group in the polymer; consequently, Nafion absorbs 22% by weight of water. Unlike micro-porous membrane permeation, which transfers water through a relatively slow diffusion process, Nafion removes water by absorption as waterof-hydration. This absorption occurs as a First Order Kinetic reaction, so equilibrium is reached very quickly (typically with in milliseconds). Because this is a specific chemical reaction with water, gases being dried or processed are usually entirely unaffected. 19 Stationary Dust Monitor / Size Distribution Jorge Anjos GRIMM # 190 Aerosol Spectrometer Counts with 31 Size Channels or Fine Dust Monitor with the same specifications as the #180 #265 semi volutile compounds Data from the E-SVC *specification of the semi volutile sompounds in ambient air * Stainless steal housing * Long term measurement * 47mm PTFE Filter possible µg/m ³ E-SVC Heater: 100 C, Intervall 20 min Ein / 40 min Aus 07:13 07:39 08:05 08:31 08:57 09:23 09:49 10:15 10:41 11:07 11:33 11:59 12:25 12:51 13:17 13:43 14:09 14:35 15:01 15:27 PM PM-2.5 Heater C

4 System Integration of GRIMM ENVIRONcheck ENVIRONMENTAL DATA IN REAL TIME Installation examples of STAND-ALONE GRIMM ENVIRONcheck Mobile Systems Stationary Systems SVC Systems WRAS Systems Particle Concentration in 15at(or Channels continuous PM-10 and PM-2.5 values the31) same time with one unit 4

5 Wide Range Aerosol Spectrometer E-WRAS Combination of the size distribution from a SMPS and a Spectrometer SMPS: 3 nm nm, 44 channels Spectrometer: 0.25 µm...30 µm, 31 channels E-WRAS: Range from 3 nm to nm (30 µm) 75 different channels 19 Rack-mounted E-WRAS Sample pipe Spectrometer # CPC + DMA #565 environmental WIDE RANGE * Count distribution from 5nm up to 31µm * 72 channels * Stainless steal housing * Long term measurement Combined Size Distribution WRAS N/cm³ mittlerer WRAS DMA 180er Kanäle [nm] N/cm³ mittlerer DMA 180er Kanäle [nm] 5

6 SVC-Semi-Volatile Compounds Field Test in Austria Particles in the ambient air consist of solid and semi-volatile components. Semi-volatile compounds make up 20% to 50% of the PM2.5 Common samplers are losing semi-volatiles due to the ongoing sampling from the filter or by heating the sample probe to prevent condensation. Result: most measurements are underestimated. 6

APPROVED by U.S. EPA As a Class III Equivalent Method Designation for the measurement of PM 2.5

APPROVED by U.S. EPA As a Class III Equivalent Method Designation for the measurement of PM 2.5 19 Stationary Dust Monitor EDM 180 APPROVED by U.S. EPA As a Class III Equivalent Method Designation for the measurement of PM 2.5 Automated Equivalent Method: EQPM-0311-195 Federal Register: Vol. 76,

More information

GAW - WCCAP recommendation for aerosol drying

GAW - WCCAP recommendation for aerosol drying GAW - WCCAP recommendation for aerosol drying Alfred Wiedensohler and Wolfram Birmili Leibniz Institute for Tropospheric Research Humidity control One particular problem during summertime or in warm and

More information

The Complete Guide to Gas Sample Drying for Your Analyzer or Process

The Complete Guide to Gas Sample Drying for Your Analyzer or Process The Complete Guide to Gas Sample Drying for Your Analyzer or Process Perma Pure LLC 8 Executive Dr. Tel. 732 244 0010 Fax 732 244 8140 The Complete Guide to Gas Sample Drying Creating a dry gas sample

More information

Thermo Scientific Model 1160 Principle of Operation

Thermo Scientific Model 1160 Principle of Operation Thermo Scientific Model 1160 Principle of Operation Thermo Scientific's Model 1160 Zero Air Supply converts ambient air to pollutant-free air. Table 1 describes the pollutants that can be removed, the

More information

CEM Istanbul - Turkey. True trace emission monitoring system

CEM Istanbul - Turkey. True trace emission monitoring system CEM 2014 Istanbul - Turkey True trace emission monitoring system Flue Gas - Can be dirty, wet, sour, hot etc. - Some species are reactive, some are soluble, some are unstable in mixtures of others - However,

More information

Audit Report. Global GAW station Pallas, Finland

Audit Report. Global GAW station Pallas, Finland Audit Report Global GAW station Pallas, Finland February 25, 2015 Prof. Dr. Alfred Wiedensohler, Dr. Thomas Tuch General: This station audit was a re-audit of the audit performed in August 2004. As in

More information

Membrane Dryers KMM Series

Membrane Dryers KMM Series www.kaeser.com Membrane Dryers KMM Series Flow volume at inlet up to. m /min Why is it necessary to dry compressed air? The atmospheric air drawn into a compressor is a mixture of gases that always contains

More information

Membrane Dryers KMM Series

Membrane Dryers KMM Series www.kaeser.com Membrane Dryers KMM Series Flow volume at inlet up to.0 m /min Why is it necessary to dry compressed air? The atmospheric air drawn into a compressor is a mixture of gases that always contains

More information

Simultaneous Real-Time Dust Mass Measurement with the

Simultaneous Real-Time Dust Mass Measurement with the Occupational Spectrometer and Fine Dust Monitor DUSTcheck Model 1.108 Simultaneous Real-Time Dust Mass Measurement with the Model 1.101 of * Inhalable, * Thoracic and * Alvelolic Part And with the model

More information

ACTIVITIES OF THE MEASURING GROUP

ACTIVITIES OF THE MEASURING GROUP ACTIVITIES OF THE MEASURING GROUP TABLE OF CONTENTS 1. Introduction 2. Flow measurements 3. Temperature measurements 3.1 Temperature profile of tunnel kiln loads 3.2 Other temperature measurements 4. Power

More information

Alphasense Application Note AAN 106 HUMIDITY EXTREMES: DRYING OUT AND WATER ABSORPTION

Alphasense Application Note AAN 106 HUMIDITY EXTREMES: DRYING OUT AND WATER ABSORPTION AAN 106 HUMIDITY EXTREMES: DRYING OUT AND WATER ABSORPTION Alphasense electrochemical toxic gas sensors are low power devices with excellent resolution, dynamic range and selectivity. These electrochemical

More information

gas monitoring system

gas monitoring system www..com gas monitoring system Photon S is s most recent and most sophisticated apparatus. It was created based on portable gas analyser - Photon. As its sucessor it also uses gas sensors as the main measurement

More information

Gas Samplers. Compact, user-friendly devices for physically correct gas volume measurements in accordance with the VDI guidelines

Gas Samplers. Compact, user-friendly devices for physically correct gas volume measurements in accordance with the VDI guidelines Gas Samplers Compact, user-friendly devices for physically correct gas volume measurements in accordance with the VDI guidelines Gas Samplers Gas Flow Sampling of gases and air pollutants Gas flow diagram

More information

Thermo Scientific TVA2020 Introduction

Thermo Scientific TVA2020 Introduction Thermo Scientific TVA2020 Introduction The Thermo ScientificT TVA2020 Toxic Vapor Analyzer, is an advanced design, portable, organic/inorganic vapor monitor for the gas survey industry. The analyzer uses

More information

DP 300 mobile dew point instrument

DP 300 mobile dew point instrument Instruction manual DP 300 mobile dew point instrument For measuring pressure, dew point and atmospheric dew point in different applications: Compressed air plants (refrigeration/ adsorption dryer) Granulate

More information

TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION

TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION Having an understanding of why water forms in your compressed air piping system will help you in evaluating the type of air drying system

More information

UNITY 2 TM. Air Server Series 2 Installation Manual. Version September 2012

UNITY 2 TM. Air Server Series 2 Installation Manual. Version September 2012 UNITY 2 TM Air Server Series 2 Installation Manual Version 1.12 September 2012 1. Installation...2 1.1. Tools required...2 1.2. Procedure...2 1.3. Requirement for a sample pump (U-ASPMP1 / U-ASPMP2)...8

More information

Characterization of Fine Particle Concentrations in an Engine Plant

Characterization of Fine Particle Concentrations in an Engine Plant Characterization of Fine Particle Concentrations in an Engine Plant William Heitbrink, Ph. D. CIH 1 Thomas Peters, Ph. D. 1 Douglas Evans, Ph. D 2 Thomas Slavin 3 1 University of Iowa, Iowa City, IA; 2

More information

Absorber products have the property of absorbing up to 500 times their weight in distilled water and they become gels.

Absorber products have the property of absorbing up to 500 times their weight in distilled water and they become gels. Human activities require more and more resources among them water is certainly the most precious. Modern agriculture consumes almost two thirds of the waters pumped worldwide. For this reason, more and

More information

A Continuous Air Monitoring Sampler for 125 I - RIS-125

A Continuous Air Monitoring Sampler for 125 I - RIS-125 A Continuous Air Monitoring Sampler for 125 I - RIS-125 S.Levinson, I.Belaish, T.Kravchik, U.German, O.Pelled, Y. Laichter, Y.Mazor, U.Wengrowicz, E.Dolev, H.Assido, D.Tirosh Nuclear Research Center Negev,

More information

LMM-H04 Mass Air FLow Sensor

LMM-H04 Mass Air FLow Sensor Mass Air FLow Sensor Product Description LMM-H04 is a thermodynamic sensing element for the unidirectional measurement of mass air flow in a well defined channel. It is dedicated for applications with

More information

Product data sheet Palas Fidas 200 S

Product data sheet Palas Fidas 200 S Product data sheet Palas Fidas 200 S Applications Regulatory environmental monitoring in measuring networks Ambient air measurement campaigns Oriented indicative measurements (spot checks) Long-term studies

More information

Diffusion Dryer Model 250

Diffusion Dryer Model 250 Accessories Diffusion Dryer Model 250 Instruction Manual P/N 1800114, Revision C December 2012 Contents Sections Introduction... 1 Unpacking... 3 Installation... 3 The Diffusion Dryer Components... 4

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland']B:' Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Ceriificate No.: 0000028733 02 AMs designation: Manufacturer: SWAM 5a Dual Channel Monitor, SWAM 5a Dual Channel Hourly Mode

More information

LMM-H03 Mass Air FLow Sensor

LMM-H03 Mass Air FLow Sensor Mass Air FLow Sensor Product Description LMM-H03 is a thermodynamic sensing element for the bidirectional measurement of mass air flow in a well defined channel. It is dedicated for applications with high

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate number: 0000028733_01 Certified AMS: Manufacturer: SWAM 5a Dual Channel Monitor for PMio and PM2,5 FAl lnstruments s.r.l.

More information

Measuring Stokes shift. Easy, fast and reliable

Measuring Stokes shift. Easy, fast and reliable raman Measuring Stokes shift Solutions Easy, fast and reliable Solutions in Raman spectroscopy Avantes, the leading Raman spectroscopy manufacturer and designer, is the choice for high quality and high

More information

INSTRUMENTATION FOR MARINE BLACK CARBON MEASUREMENTS

INSTRUMENTATION FOR MARINE BLACK CARBON MEASUREMENTS INSTRUMENTATION FOR MARINE BLACK CARBON MEASUREMENTS Workshop on Marine Black Carbon Emissions, Ottawa, 9-10 th of September 2014 1 Outline IMO Measurement Methods and Definitions for Black Carbon Selectivity

More information

Membrane Technologies DMD Series Dryers ESM Series Dryers

Membrane Technologies DMD Series Dryers ESM Series Dryers Membrane Technologies DMD Series Dryers ESM Series Dryers Membrane Technologies Energy Saving Compressed Air Dryers People around the globe have relied on Deltech to deliver energy efficiency and value

More information

Cyclonic Separator. Condensate Separator. No Air Loss Drain. Condensate Management. People. Passion. Performance.

Cyclonic Separator. Condensate Separator. No Air Loss Drain. Condensate Management. People. Passion. Performance. Cyclonic Separator Condensate Separator No Air Loss Drain Condensate Management People. Passion. Performance. Removal of Contaminants in Compressed Air Condensate During the compression process, contaminants

More information

? Radiation. Radiation. How does heat energy get from the Sun to the Earth?

? Radiation. Radiation. How does heat energy get from the Sun to the Earth? How does heat energy get from the Sun to the Earth? Radiation There are no particles between the Sun and the Earth so it can not travel by conduction or by convection.? Radiation Radiation Thermal radiation

More information

portable gas analyser

portable gas analyser www..com portable gas analyser The largest of s analysers equipped with electrochemical cells. It can fit even up to 7 EC cells and up to 3 sensors. GA-60 has a large (320*240), graphical LCD with backlighting.

More information

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu) PART 1 - GENERAL A. RELATED DOCUMENTS SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu) Federal, State, and local requirements as applicable. Attached Permit Attached drawings B. SUMMARY 1. Provide

More information

VM-3000 Mercury Vapor Monitor

VM-3000 Mercury Vapor Monitor MERCURY INSTRUMENTS ANALYTICAL TECHNOLOGIES VM-3000 Mercury Vapor Monitor Continuous mercury measurement in air and other gases Direct reading mercury vapor meter Portable, integrated battery for 6 hours

More information

Mini Spray Dryer B-290 Technical data sheet

Mini Spray Dryer B-290 Technical data sheet Mini Spray Dryer B-290 Technical data sheet The Mini Spray Dryer B-290 is the world leading laboratory scale Spray Dryer since many years. It is designed to visualize your Spray Drying process for wide

More information

Quality and Technology - Made in Germany -

Quality and Technology - Made in Germany - Quality and Technology - Made in Germany - TRACERLAB GmbH Aachener Str. 1354 50859, Koeln, Germany Tel.: +49 (0) 2234-942397 Fax.: +49 (0) 2234-942398 E-mail: asktracerlab@tracerlab.com Internet: www.tracerlab.com

More information

ANNEX I. Technical specifications for: Supply of various Trace Explosive Detection Systems

ANNEX I. Technical specifications for: Supply of various Trace Explosive Detection Systems EUROPEAN COMMISSION JOINT RESEARCH CENTRE Institute for Reference Materials and Measurements (Geel) ANNEX I Technical specifications for: Supply of various Trace Explosive Detection Systems TABLE OF CONTENTS

More information

Three categories of instruments

Three categories of instruments Instrument Descriptions Part 2 of 2 Three categories of instruments are discussed in this report: optical real-time, continuous particulate monitors, mass quantifying real-time continuous particulate monitors,

More information

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture meas. according to ISO 8573 Residual oil content - particles - moisture DS 500 - the intelligent chart recorder of the next generation. The centerpiece of compressed air quality measurement is the chart

More information

FIDAS FINE DUST MONITORING SYSTEMS

FIDAS FINE DUST MONITORING SYSTEMS FIDAS FINE DUST MONITORING SYSTEMS Fidas 200 S The world s only certified optical fine dust measurement system with single particle analysis for PM 2. 5 PM 10 1 APPLICATIONS Measurements at workplaces

More information

CMMD Series Membrane Air Dryer

CMMD Series Membrane Air Dryer CMMD Series Membrane Air Dryer NEW Engineered to Save CMMD Series Compressed Air Dry Air Membrane Drying CompAir s CMMD Series membrane air dryer offers a pointofuse alternative for low dew point applications

More information

Membrane Dryer. Air inflow rate KMM Series to m 3 /min

Membrane Dryer. Air inflow rate KMM Series to m 3 /min Membrane Dryer Air inflow rate KMM Series 0.08 to. m /min Why is it necessary to dry compressed air? The atmospheric air drawn into a compressor is a mixture of gases that always contains water vapour.

More information

VENTING IS ALL AROUND US

VENTING IS ALL AROUND US VENTING IS ALL AROUND US Vents are everywhere in our cell phones and computer hard drives, in the brakes and headlights on our cars, even in our shampoo and detergent bottles. They re often hidden from

More information

Unit THE NATURE OF HEAT

Unit THE NATURE OF HEAT Unit 5.0 - THE NATURE OF HEAT Heat is a form of energy, in the form of infrared radiation. Heat from the sun travels through space at the speed of 300,000,000 m/s. Upon arriving on earth, much of the radiant

More information

A white paper. Engineering GREAT Solutions. Compressed Air Dryers for the rail industry

A white paper. Engineering GREAT Solutions. Compressed Air Dryers for the rail industry A white paper Engineering GREAT Solutions Compressed Air Dryers for the rail industry 02 A white paper A white paper 03 Executive Summary The use of compressed air technology in the rail industry has always

More information

Mercury Vapor Monitor VM-3000

Mercury Vapor Monitor VM-3000 Member of the envea Group Mercury Vapor Monitor VM-3000 Continuous mercury measurement in air and other gases Direct reading mercury vapor meter Proven reliable detection method: UV absorption (CVAAS)

More information

Apex E Quick Installation Guide

Apex E Quick Installation Guide ELEMENTAL SCIENTIFIC INC. Apex E Quick Installation Guide Apex E Quick Installation Guide ã Elemental Scientific Inc. 2440 Cuming Street Omaha, NE 68131 USA Phone 402.991.7800 Fax 402.991.7799 Table of

More information

Low-Frequency Raman Spectroscopy Enabling Affordable Access to the Terahertz Regime

Low-Frequency Raman Spectroscopy Enabling Affordable Access to the Terahertz Regime Low-Frequency Raman Spectroscopy Enabling Affordable Access to the Terahertz Regime James Carriere and Frank Havermeyer Ondax, Inc: Booth #48 SCIX/FACSS: 10/3/2012 Paper 532 Motivation Low-frequency Raman

More information

Product data sheet Palas Promo 2000

Product data sheet Palas Promo 2000 Product data sheet Palas Promo 2000 Applications Emission monitoring of installations Control of grinding and classification processes Monitoring of production processes in the food, pharmaceuticals and

More information

AEROSOL SPECTROMETERS

AEROSOL SPECTROMETERS AEROSOL SPECTROMETERS Top resolution, the best classification accuracy, coincidence detection and correction of the individual signal 1 APPLICATIONS Research and development, environmental measurements

More information

Application Note. Measuring Hot Liquid Samples AN

Application Note. Measuring Hot Liquid Samples AN Application Note AN 1030.00 Measuring Hot Liquid Samples Abstract When a material is in the form of a solid, powder or crystal, detecting small color differences can be made easier by dissolving the sample

More information

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

Laser Analyzers for NH3 Safety Monitoring and Leak Detection Laser Analyzers for NH3 Safety Monitoring and Leak Detection Boreal s Worldwide Clients Over 450 systems in 42 Countries Holland Belgium France Germany Italy England Scotland Norway Iceland Canada United

More information

International comparison of validation methods for dust concentration measurement

International comparison of validation methods for dust concentration measurement International comparison of validation methods for dust concentration measurement Validation of dust monitors can be divided into 2 steps: 1. Validation of a generic dust monitor as an instrument (Type

More information

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207 EN - english Instructions for installation and operation Mobile humidity meter DP 207 Dear customers, Thank you very much for deciding in favour of the mobile humidity measuring instrument DP 207. Please

More information

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications Data Sheet 907020 Page 1/9 Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications For measuring relative humidity and temperature For versatile climatic applications and ventilation

More information

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer Model 6650SP Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer 6650SP - OVERVIEW The Model 6650SP is the next generation in-water Analyzer. The 6650SP incorporates the most advanced, state-of-the-art

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the GC 866 PID airtoxic (Model A73022) manufactured by: Chromatotec / airmotec 15, Rue d Artiguelongue Saint -Antoine 33240 Val de Virvée France has

More information

integrated sludge treatment combined sludge drying and incineration

integrated sludge treatment combined sludge drying and incineration integrated sludge treatment combined sludge drying and incineration combined sludge drying and incineration Sludge is the unwanted by-product of the wastewater treatment process. After mechanical dewatering

More information

VM-3000 Mercury Vapor Monitor

VM-3000 Mercury Vapor Monitor MERCURY INSTRUMENTS Analytical Technologies VM-3000 Mercury Vapor Monitor Continuous mercury measurement in air and other gases Direct reading mercury vapor meter Proven reliable detection method: UV absorption

More information

Company profile. ANKERSMID is a privileged partner of several companies like Siemens, BASF, Bayer, Umicore, Dräger and many more.

Company profile. ANKERSMID is a privileged partner of several companies like Siemens, BASF, Bayer, Umicore, Dräger and many more. ANKERSMID is well-known on the market for more than 30 years now and subsidiaries in several countries (Belgium, Netherlands, France, China, Romania, Germany etc.) with more than 100 employees world-wide

More information

Background. Totech dry cabinet

Background. Totech dry cabinet Background Moisture and Surface Mount Components do not mix Plastic packaging material very often is permeable to moisture If moisture levels become critical, component damage may occur when heated during

More information

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions. Personal Alpha/Beta Continuous Air Monitor (CAM) The pocamon (personal online continuous air monitor) monitors continuously the breathing air to detect airborne radioactive aerosols (LLRD). Typical application

More information

Gaseous detectors. 1

Gaseous detectors.  1 Gaseous detectors Very important class of detectors with many applications charged particle, x- & gamma rays, visible light detection applications in many areas of research, & commercial particle & nuclear

More information

Complete Gas Analysis

Complete Gas Analysis Complete Gas Analysis A complete range of gas analysers, systems and accessories for emissions, air quality, research and process monitoring. The Signal Group, incorporating the gas analysis business of

More information

Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated. Beaker

Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated. Beaker Lab Equipment Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated. Beaker Erlenmeyer Flask Erlenmeyer flasks hold solids or liquids

More information

METPOINT THE COMPLETE RANGE OF PRECISION CONTROL DEVICES FOR COMPRESSED AIR DEW POINT, FLOW, AND LEAKAGE

METPOINT THE COMPLETE RANGE OF PRECISION CONTROL DEVICES FOR COMPRESSED AIR DEW POINT, FLOW, AND LEAKAGE THE COMPLETE RANGE OF PRECISION CONTROL DEVICES FOR COMPRESSED AIR DEW POINT, FLOW, AND LEAKAGE METPOINT DPM DEW POINT MONITORS Moisture in compressed air can cause severe damage. Malfunctions in a production

More information

METPOINT OCV. e. g. SAFE PROCESS THROUGH MONITORING. FOR CHALLENGING COMPRESSED-AIR APPLICATIONS Pharmaceuticals. Food Chemical Coating

METPOINT OCV. e. g. SAFE PROCESS THROUGH MONITORING. FOR CHALLENGING COMPRESSED-AIR APPLICATIONS Pharmaceuticals. Food Chemical Coating SAFE PROCESS THROUGH MONITORING FOR CHALLENGING COMPRESSED-AIR APPLICATIONS Pharmaceuticals Food Chemical Coating e. g. PAYS ATTENTION MONITORED FREEDOM FROM OIL Oil-contaminated compressed-air is a concern

More information

Model 850 Investigator s Aid Accelerant and Gas Detector Operation and Maintenance

Model 850 Investigator s Aid Accelerant and Gas Detector Operation and Maintenance Model 850 Investigator s Aid Accelerant and Gas Detector Operation and Maintenance www.graceindustries.com M850TM1215 December 2015 1 1. Cover 2. Table of Contents 3. Top View 4. Features & Benefits 5.

More information

How The Air Oasis Air Purifiers Work The Air Oasis Mini, 1000, 3000, 3000 Xtreme, 5000 Commercial and Air Oasis Induct air purifiers utilize a

How The Air Oasis Air Purifiers Work The Air Oasis Mini, 1000, 3000, 3000 Xtreme, 5000 Commercial and Air Oasis Induct air purifiers utilize a How The Air Oasis Air Purifiers Work The Air Oasis Mini, 1000, 3000, 3000 Xtreme, 5000 Commercial and Air Oasis Induct air purifiers utilize a state-ofthe-art, patent-pending high-performance metallic

More information

_03 / 28 July 2015

_03 / 28 July 2015 Test report: 936/21221789/B of 19 March 2013 Initial certification: 02 August 2010 Certificate: renewal (previous certificate 0000027277_02 of 20 August 2013 valid until 01 August 2015) Date of expiry:

More information

SYNRAD Technical Bulletin # 0015d

SYNRAD Technical Bulletin # 0015d Page 1 of 6 SYNRAD Technical Bulletin # 0015d Technical Issue: Purge Gas Conditioning for f201/f400, i401, & p100/p250 Lasers Date: 30 July 2014 Description: This Technical Bulletin describes how to prevent

More information

Emission Monitoring System

Emission Monitoring System Advance Cemas-FTIR Multi-component Emission Monitoring System System Description 30/23-200-1 EN System Overview Measurement principle The Advance Cemas FTIR is a multi-component emission monitoring system

More information

clean and quiet laboratory

clean and quiet laboratory clean and quiet laboratory clean air for your lab JUN-AIR introduced the first compressor almost 50 years ago and started the development of the technology and design, which has made JUN-AIR compressors

More information

ISO AIR FILTERS FOR GENERAL VENTILATION: DETERMINING FRACTIONAL EFFICIENCY

ISO AIR FILTERS FOR GENERAL VENTILATION: DETERMINING FRACTIONAL EFFICIENCY ISO 16890-2 AIR FILTERS FOR GENERAL VENTILATION: DETERMINING FRACTIONAL EFFICIENCY APPLICATION NOTE AFT-005 (US) Contents Introduction to ISO 16890... 1 How ISO 16890 Compares to EN 779 and ASHRAE 52.2...

More information

IR25 Dual Gas Series Datasheet

IR25 Dual Gas Series Datasheet SGX Europe Sp. z o.o. IR25 Dual Gas Series Datasheet Infrared Dual Gas Sensor for Mining (Portable and Fixed Systems) The SGX infrared sensors use the proven Non-Dispersive Infrared (NDIR) principle to

More information

Active Dry Air Venting for Water Contamination Control

Active Dry Air Venting for Water Contamination Control . PO Box 1299 Minneapolis, MN 5544 USA Industrial Hydraulics 1-8-846-1846 grphydfilters@donaldson.com Active Dry Air Venting for Contamination Control While required for biological life, water can be extremely

More information

Oil Mist Eliminators PMR Series

Oil Mist Eliminators PMR Series Oil Mist Eliminators PMR Series Section 60 Bulletin A-6 Pneumatech s Mist Eliminators combine superior performance in particle elimination with an unmatched service life. Typically used as the pre-filter

More information

Refrigeration Dryers TG TI Series

Refrigeration Dryers TG TI Series www.kaeser.com Refrigeration Dryers TG TI Series Flow rate. to. m³/min Why is it necessary to dry compressed air? The atmospheric air drawn into a compressor is a mixture of gases that always contains

More information

Nano Spray Dryer B-90 HP Technical data sheet

Nano Spray Dryer B-90 HP Technical data sheet Nano Spray Dryer B-90 HP Technical data sheet Gently processing of small sample amounts into sub-micron particles with little loss are the key features characterizing the Nano Spray Dryer B-90. The 2 nd

More information

Certificate: / 29 April 2014

Certificate: / 29 April 2014 Test report: 936/21209885/F of 20 September 2013 Initial certification: 01 April 2014 Date of expiry: 31 March 2019 Publication: BAnz AT 01 April 2014 B12, chapter IV, No. 6.3 Approved application The

More information

Hygro/hygrothermal transducers (hygrometric)

Hygro/hygrothermal transducers (hygrometric) Data Sheet 907031 Page 1/7 Hygro/hygrothermal transducers (hygrometric) for measuring relative humidity and temperature for mounting indoors, outdoors, and in air ducts with resistance, current or voltage

More information

Removing the moisture contents of coal using solar drying

Removing the moisture contents of coal using solar drying Case Study 2 Removing the moisture contents of coal using solar drying Implementing the technology A wall and floor tiles industry uses spray dryers for the formation of granules. The hot gases to the

More information

How To Use Spawn Bags

How To Use Spawn Bags Midwest Grow Kits Revision 4.1; 2018 How To Use Spawn Bags This guide will show you how to properly Inoculate and Grow your Rye or 5-Grain Spawn Bags Each bag has a self-healing injector site, which closes

More information

Waveguide Dehydrators

Waveguide Dehydrators Waveguide Dehydrators Clean & Dry Air For Clear Communications Rugged & Reliable Compressed Air Systems for: TV and Radio Broadcast Applications Satellite Radar Aerospace Telecommunications Military Custom

More information

VarioDry SPN

VarioDry SPN Dryer VarioDry Technologies SPN 0003-0063 Membrane Air Dryers VarioDry SPN 0003-0063 MAIN FEATURES & BENEFITS: Very low purge air Lightweight design Nine types with 3,0 up to 63 Dew point reduction down

More information

SCHEUCH ELECTROSTATIC PRECIPITATORS INNOVATIVE TECHNOLOGIES FOR DEDUSTING FLUE GASES

SCHEUCH ELECTROSTATIC PRECIPITATORS INNOVATIVE TECHNOLOGIES FOR DEDUSTING FLUE GASES SCHEUCH ELECTROSTATIC PRECIPITATORS INNOVATIVE TECHNOLOGIES FOR DEDUSTING FLUE GASES THE FORMULA FOR CLEAN AIR THE BASIC ELECTROSTATIC PRINCIPLE PARTICLE CHARGING AND SEPARATION The particle separation

More information

Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated. Beaker

Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated. Beaker Lab Equipment Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated. Beaker Erlenmeyer Flask Erlenmeyer flasks hold solids or liquids

More information

Operate the Mutli-Gas Monitor PID

Operate the Mutli-Gas Monitor PID TASK: Operate the Multi-Gas Monitor Learning Objective CONDITION: In a classroom environment, given a fully charged Multi-gas Monitor with the manufacturer operator s manual, all monitor components/accessories,

More information

Chemical warfare agent detection. Lesson topic 4.2

Chemical warfare agent detection. Lesson topic 4.2 Chemical warfare agent detection Lesson topic 4.2 Enabling Objectives Perform the procedures to detect and classify chemical agent stimulants Describe the characteristics and capabilities of shipboard

More information

HP 101A Series Humidity Temperature Probes INSTRUCTION MANUAL

HP 101A Series Humidity Temperature Probes INSTRUCTION MANUAL HP 101A Series Humidity Temperature Probes INSTRUCTION MANUAL -2- CONTENTS DESCRIPTION... 3 OPERATION... 4 MEASUREMENT... 5 MAINTENANCE... 7 CALIBRATION BASICS... 8 CALIBRATION PROCEDURE... 10 SPECIFICATIONS...

More information

FEEDGAS FOR MODERN HIGH-PERFORMANCE OZONE GENERATORS. Bruce T. Stanley. Ozonia Ltd Duebendorf, Switzerland 1999

FEEDGAS FOR MODERN HIGH-PERFORMANCE OZONE GENERATORS. Bruce T. Stanley. Ozonia Ltd Duebendorf, Switzerland 1999 FEEDGAS FOR MODERN HIGH-PERFORMANCE OZONE GENERATORS Bruce T. Stanley Ozonia Ltd Duebendorf, Switzerland 1999 Abstract The traditional way of producing ozone is by means of Dielectric Barrier Discharge

More information

CONFIRMATION of Product Conformity (QAL1)

CONFIRMATION of Product Conformity (QAL1) CONFIRMATION of Product Conformity (QAL1) AMS designation: Manufacturer: Test Laboratory: Fidas 200 S, Fidas 200 and Fidas 200 E for suspended particulate matter PM 10 and PM 2,5 PALAS GmbH Greschbachstraße

More information

AirCel. AG Aluminum. SH Steel. Industrial Filter Housings

AirCel. AG Aluminum. SH Steel. Industrial Filter Housings AirCel AG Aluminum SH Steel Industrial Filter Housings Ultradri water separators at compressor aftercoolers AG Superplus coalescing prefilter before compressed air dryer AG Superplus particulate afterfilter

More information

CLEARPOINT THE WINNING COMBINATION FOR CLEAN COMPRESSED AIR

CLEARPOINT THE WINNING COMBINATION FOR CLEAN COMPRESSED AIR CLEARPOINT THE WINNING COMBINATION FOR CLEAN COMPRESSED AIR CLEARPOINT COST SAVINGS BASED ON ENERGY COST REDUCTION THE BIGGEST POTENTIAL FOR SAVINGS IS IN THE REDUCTION OF YOUR ENERGY AND MAINTENANCE COSTS.

More information

Division III Process Gas Treatment Equipment

Division III Process Gas Treatment Equipment ASME AG-1 Committee on Nuclear Air and Gas Treatment Division III Process Gas Treatment Equipment Chairman, SC Gas Process Treatment August 2008 - p 1 ASME AG-1 Division I General Requirements Division

More information

Desiccant Dryers DC Series (Heatless regenerated) Air flow rates 0.15 to m³/min.

Desiccant Dryers DC Series (Heatless regenerated) Air flow rates 0.15 to m³/min. Desiccant Dryers DC Series (Heatless regenerated) Air flow rates.5 to 5.5 m³/min www.kaeser.com Why is it necessary to dry compressed air? The atmospheric air drawn into a compressor is a mixture of gases

More information

Hemi Anechoic Chamber Number:

Hemi Anechoic Chamber Number: 1 of 6 Hemi Anechoic Chamber Architecture: 2 of 6 * Concrete floor and walls * Control room dimensions = 20 x 15 X 10 Feet. 3 of 6 Inner View / Features (not limited to below listing): * only a representative

More information

High Inlet Temperature Air Dryer. Desiccant Air Dryer. Membrane Air Dryer After-Clooler. Air Filter. Oil-Water Separator Automatic Drain Value

High Inlet Temperature Air Dryer. Desiccant Air Dryer. Membrane Air Dryer After-Clooler. Air Filter. Oil-Water Separator Automatic Drain Value High Inlet Temperature Air Dryer Membrane Air Dryer After-Clooler Oil-Water Separator Automatic Value 1 2 3 4 5 6 7 8 9 1 HYD model Control Panel 1. on HYD-150 and smaller - It is equipped with a low pressure

More information

RAID-S2. Innovation with Integrity. Stationary Rapid Alarm and Identification Device. Defence CBRNE

RAID-S2. Innovation with Integrity. Stationary Rapid Alarm and Identification Device. Defence CBRNE RAID-S2 Stationary Rapid Alarm and Identification Device Innovation with Integrity Defence CBRNE General Specification Proved IMS technology The RAID-S2 is a gas trace detector for the detection of chemical

More information

VOCs in soil remediation

VOCs in soil remediation A buyer s guide to measuring VOCs in soil remediation Typical photoionisation detectors measure volatile organic compounds and other gases in concentrations from sub parts per billion to 10 000 parts per

More information