2M-W353 Rev. I 1/07/ S IL1381

Size: px
Start display at page:

Download "2M-W353 Rev. I 1/07/ S IL1381"

Transcription

1 SELECTRONIC ELECTRIC GRIDDLE Commercial & Marine S, SHE, SCHE S, S-SC, SHE S, SHE, SR 0S, 0SHE, 0SR, 0S-SC S, SR, SC Installation and Operation Instructions M-W Rev. I /0/0 IL S

2 SAFETY SYMBOL These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance. FOR YOUR SAFTEY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINTIY OF THIS OR ANY OTHER APPLIANCE. POST IN PROMINENT LOCATION INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS. THIS INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER. AS A MINIMUM, TURN OFF THE GAS AND CALL YOUR GAS COMPANY AND YOUR AUTHORIZED SERVICE AGENT. EVACUATE ALL PERSONNEL FROM THE AREA. WARNING IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT. WARNING RISK OF FIRE OR ELECTRIC SHOCK DO NOT OPEN WARNING, TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE CONTROL PANEL. NO USER-SERVICABLE PARTS INSIDE. REPAIRS SHOULD BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY. NOTICE Using any part other than genuine Lang factory supplied parts relieves the manufacturer of all liability. Lang reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment. Due to periodic changes in designs, methods, procedures, policies and regulations, the specifications contained in this sheet are subject to change without notice. While Lang exercises good faith efforts to provide information that is accurate, we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifications. By using the information provided, the user assumes all risks in connection with such use. MAINTENANCE AND REPAIRS Contact your local dealer for service or required maintenance. Please record the model number, serial number, voltage and purchase & Installation Information in the area below and have it ready when you call to ensure a faster service. Model No.: Serial No.: Voltage: Purchased From: Location: Purchase Date: -Phase or Phase: Installed Date:

3 PROBLEMS, QUESTIONS or CONCERNS Before you proceed consult you authorized Lang service agent directory or Call the Lang Technical Service & Parts Department at --. TABLE OF CONTENTS Specifications Equipment Description Unpacking Installation Leg Installation Ventilation & Clearence Electrical Connection Technical Data Phasing Initial Start-Up Pre-Power On Power On Seasoning Cooking Surface Operation General Operations Suggested Times and Temperatures Maintenance Cleaning Troubleshooting Symptoms / Possible Causes Possible Causes / Test Wiring Diagram 0/0VAC VAC VM V, w/cse Hoods Exploded View & Parts List NOTICE Service on this or any other Lang appliance must be performed by qualified personnel only. Consult your Lang Authorized Service Agent Directory. You can call our tech service number -- or visit our website for the service agent nearest you.

4 EQUIPMENT SPECIFICATIONS Model 0 Height x Width x Depth Clearance from Weight (Not including legs) combustible surface Actual Shipping.0" x.0" x." lbs. 0 lbs. mm x 0mm x mm 0 kg kg.0" x.0" x." lbs. 0 lbs. mm x mm x mm kg kg.0" x.0" x." Sides: " lbs. lbs. mm x mm x mm Back: " 0 kg kg.0" x 0.0" x." lbs. lbs. mm x mm x mm kg 0 kg.0" x.0" x." lbs. 00 lbs. mm x 0mm x mm kg kg Freight Class. Elec. Connect. Elec. Connect. (0 & only) W D H (0.mm) IL. Elec. Connect.

5 EQUIPMENT SPECIFICATIONS Current Model Volts AC Hz. PHASE Supply Kw Amp Amp Ph Supply Supply Kw Amp Amp Ph Supply Wire Wire Wire Wire TOT. PH. TOT. PH. PH L L L PH PH L L L PH S 0/0 0 / 0 SC 0/0 0 / 0 S-0V 0 0 SHE 0/0 0 / 0 SHE-0F 0 0 SCHE 0/0 0 / 0 S 0/0 0 / S-0V 0 0/ S-0V 0 0 SHE-0V SB-WB 0/0 0 / SHE 0/0 0 / SCHE 0/0 0 / SC 0/0 0 / S-SC 0/0 0 / SC 0V S 0/0 0 / 0 S-0V 0 0/0 S-0V 0 0 SHE-0V 0 0 S-SC 0/0 0 / 0 0S 0/0 0 / S-0V 0 0 0SC 0/0 0 / SHE 0/0 0 / SHE-0V 0 0 0SCHE-0V 0 0 0SR 0/0 0 / S-SC 0/0 0 / S-WB 0/0 0 / S 0/0 0 / S-0V 0 0 SR 0/0 0 / S-SC 0/0 0 / Current Model Volts AC Hz. Ph. Supply Amp Ph Supply Supply Amp Ph Supply Kw Amp Kw Amp Wire Wire Wire Wire TOT. PH TOT. PH PH L L L PH PH L L L PH S-0VM 0/0 0 / 0 S-0VM 0V 0/ S-0VM 0V 0 SC-0VM 0/0V 0 / S-0VM 0V S-0VM SC-0VM 0V 0... S-0VM 0V 0 S-0VM 0V 0 0S-M 0/0V 0 / S-0VM 0V SM 0/0V 0 / S-0VM 0V 0 SPECIFICATIONS MARINE MARINE EQUIPMENT IS APPROVED FOR INSTALLATION ONLY ON VESSELS GREATER THAN FEET IN LENGTH, IN ACCORDANCE WITH USCG REGULATIONS IN TITLE CFR 0-. ANY WIRING USED IN THE INSTALLATION OF THIS APPLIANCE MUST BE STRANDED COPPER.

6 EQUIPMENT DESCRIPTION Griddle Surface Rear Gutter (certian models) Gutter Grease Pan Legs IL Main Section Power Switch Section Power Switch Section Temp. Dial Exterior Construction The griddle dimensions are (.cm) High, 0 (.0cm) Deep, and width is dependent on the actual model number. The Sides, Bottom, and Rear wall are constructed of double wall stainless steel, which allows closer installation to combustible surfaces. The griddle surface is made of thick, highly polished steel to reduce hot and cold spots, recovery problems, warping, and ensure even heat to the edges of the griddle. Controls Each twelve-inch section has its own temperature selector switch that snaps into place to lock in any temperature from F to 0 F ( C to C) in increments. Each twelve-inch section of the griddle is controlled by an area sensitive RTD probe, which can sense and react to a temperature change of +/- F. Each twelve-inch section has a set of K.W. elements for high efficiency, quick recovery and outstanding performance Technical The 00 Series Selectronic griddle operates on either 0/0V or 0V, at either single or three phase. This must be specified when ordering. Minimum clearances: from side and back NOTICE The data plate is on the right side of the griddle. The oven voltage, wattage, serial number, wire size, and clearance specifications are on the data plate. This information should be carefully read and understood before proceeding with the installation.

7 UNPACKING Receiving the Griddle Upon receipt, check for freight damage, both visible and concealed. Visible damage should be noted on the freight bill at the time of delivery and signed by the carrier s agent. Concealed loss or damage means it does not become apparent until the merchandise has been unpacked. If concealed loss or damage is discovered upon unpacking, make a written request for inspection by the carrier s agent within days of delivery. All packing material should be kept for inspection. Do not return damaged merchandise to Star Manufacturing Company. File your claim with the carrier. Location Prior to un-crating, move the oven as near to its intended location as practical. The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways. Un-crating The griddle will arrive completely assembled inside a wood frame and strapped to a skid. Cut the straps and remove the wood frame. The oven can now be removed from the skid. THE UNIT IS EXTREMELY HEAVY. FOR SAFE HANDLING, INSTALLER SHOULD OBTAIN HELP AS NEEDED, OR EMPLOY APPROPRIATE MATERIALS CAUTION HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY, OR PALLET JACK) TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO THE PLACE OF INSTALLATION. ANY STAND, COUNTER OR OTHER DEVICE ON WHICH OVEN WILL BE LOCATED MUST BE DESIGNED TO SUPPORT THE WEIGHT OF THE GRIDDLE. SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.

8 INSTALLATION IL Std Leg Above: typical leg installation. Marine Bolt Down Leg DANGER: WARNING NOTICE: NOTICE: CAUTION Leg Installation There are four, legs provided for, and foot griddles.. There are eight legs provided for and foot griddles. The legs are shipped in the grease drawers of the griddle. Install them into the threaded For bolt down legs see above illustration for dimensions. holes on the underside of the griddle body. Leveling adjustment may be done by screwing the bottom portion of the leg in and out. THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL PROVIDED. FAILURE TO GROUND THE APPLIANCE COULD RESULT IN ELECTROCUTION AND DEATH. INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT. UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES. The data plate is located behind access panel between controls and grease drawer. The grill voltage, wattage, serial number, wire size, and clearance specifications are on the data plate. This information should be carefully read and understood before proceeding with the installation. The installation of any components such as a vent hood, grease extractors, fire extinguisher systems, must conform to their applicable National, State and locally recognized installation standards. ALWAYS KEEP THE AREA NEAR THE APPLIANCE FREE FROM COMBUSTIBLE MATERIALS. KEEP FLOOR IN FRONT OF EQUIPMENT CLEAN AND DRY. IF SPILLS OCCUR, CLEAN IMMEDIATELY, TO AVOID THE DANGER OF SLIPS OR FALLS. IL0

9 INSTALLATION cont. Ventilation and Clearances Standard minimum clearance from combustible construction is as follows. from side from back These griddles may be set directly, without legs, on a curbed base or non-combustible surface. If the griddle is set without legs on a non-combustible floor or a curbed base, maintain a -inch back clearance. Do not install the griddle directly against a non-combustible back wall or surface. Do not install the griddle closer than inches from an uncontrolled heat source (char broiler etc.). Keep the appliance area free and clear of combustible material and do not obstruct the flow of combustion or ventilation air. Electrical Connection There is one power supply connection on the,, and -foot griddles. There are two power supply connections on and -foot griddles. Refer to the power supply chart in the Technical Data portion of this manual, for proper power supply size. There is () one /-inch conduit knockout on, and -foot griddles located at the rear of the griddle, through the back and the bottom of the griddle body. There are () two /-inch conduit knockouts provided on the and -foot griddles. Use a supply wire suitable for at least 0 degree centigrade. This Selectronic griddle is shipped from the factory, wired for 0/0 or 0 volts, the 0/0 griddle is a dual voltage design. Jumper wires on terminal strip next to the main power supply connection determine the griddle voltage. For a 0-volt power supply, leave the jumpers in place. For a 0-volt power supply disconnect the jumpers as indicated on the tag on the terminal strip. The 0-volt griddle can be operated on 0 volts only and must be specified when ordering. Technical Data NOMINAL AMPS PER LINE THREE PHASE SINGLE PHASE 0 Volt 0 Volt 0 Volt MODEL TOTAL NUMBER K.W. L L L L L L L L L 0V 0V # # # # Phasing All griddles are shipped from the factory set up for a three-phase service. Rearrange the wires in the power supply terminal block to convert the griddle to single phase. Re-phasing the griddle is not chargeable to Lang Manufacturing Company as warranty. To convert to single-phase have a Lang Authorized Service Agent, follow this chart. MODEL NUMBER PHASING BY WIRE NUMBER THREE PHASE SINGLE PHASE LINE LINE LINE LINE LINE S,,, S,,,,,,, S,,,,,,,,,,,, 0S #,,,,,,, 0S #,,, S #,,,,,,, S #,,,,,,,

10 INITIAL START UP Pre-Power On Before starting the griddle for the first time, clean the griddle body and cooking surface. Use a mild soap and water solution, then rinse with clear water and dry. Power On Set the main power switch, located at the far left of the control panel, to the ON (up) position (there are two ON switches on and foot griddles). Set each cooking section s power switch, located next to each temperature dial, to the ON (up) position. Set the temperature dials to 00 F. Heat the griddle at 00 F ( C) for hours to evaporate any moisture that may be in the elements. After hours at 00 F ( C), turn the temperature up to 0 F ( C) for ½ hour. After the griddle reaches 0 F ( C) for ½ hour, turn the griddle up another 0 F (0 C) for another ½ hour and repeat this until it is at 0 F ( C) for ½ hour. The unit may emit a small amount of smoke as the cooking surface passes the 00 F ( C) point. Do not be alarmed as the smoke is caused by oils associated with the manufacturing process and will stop when the griddle reaches 0 F ( C). Seasoning Cooking Surface (Non-Chrome Only) The cooking surface must be seasoned in order to eliminate product sticking during cooking. To season, heat the griddle to 0 F ( C). Once at 0 F ( C), coat the cooking surface with non-salted vegetable oil. Allow the griddle to stand at 0 F ( C) until the cooking surface looks dry then coat it again. Heat the griddle to 0 F ( C) and repeat the procedure. NOTICE: During the first few hours of operation you may notice a small amount of smoke coming off the griddle, and a faint odor from the smoke. This is normal for a new griddle and will disappear after the first few hours of use. 0

11 OPERATION General The suggested time and temperature chart (below) is provided as a guide for the products listed only. If different temperature settings are to be used, select one side of the griddle and operate at the lowest temperature. Adjoining sections should be set at progressively higher temperatures. Do not try to operate the end sections hot and the center sections cool. ALWAYS KEEP THE AREA NEAR THE APPLIANCE FREE FROM COMBUSTIBLE MATERIALS. CAUTION KEEP FLOOR IN FRONT OF EQUIPMENT CLEAN AND DRY. IF SPILLS OCCUR, CLEAN IMMEDIATELY, TO AVOID THE DANGER OF SLIPS OR FALLS. Operations An understanding of how the griddle sections are controlled will be a valuable aid in loading product on your unit. Each -inch section of your griddle is independently controlled by a temperature controller. The temperature control sensor is mounted in the center of each cooking section under the griddle plate. If the product is loaded directly over the temperature sensor, that section will turn on and the burner will heat the entire cooking section. If the product is loaded to the side, front or back of the temperature sensor, the thermostat will react to the temperature change much slower. During slow periods with minimal loads, do not load directly over the thermostat sensors as this will unnecessarily turn the burners on and overheat the remainder of the section not being utilized. SUGGESTED TIMES AND TEMPERATURES PRODUCTS TEMPERATURE F / C TIME (MIN) HAMBURGER patties per LB 0 F / C to patties per LB to patties per LB to STEAKS / to / inch thick, cooked medium to F / 0 C / to inch thick, cooked medium to 0 Turn the product and continue cooking until it has reached its desired degree of doneness. Remove the product from the griddle. When reloading the griddle, first use the griddle surface on which a previous load was not placed. This will help insure the proper griddle temperature. Lamb Chops to 0 F / C Pork Chops to Salmon 0 F / C to Halibut to F / C Snapper to Hash Brown Potatoes F / 0 C to Bacon to 0 F / C Sausage Links or Patties to Ham (Pre-cooked) F / 0 C Eggs F / C to Note: The times and temperatures in this chart are intended as a general guide and starting point. Your actual times and temperatures may vary from this chart.

12 MAINTENANCE & CLEANING Cleaning Always start with a cold griddle. The stainless exterior can easily be cleaned using a good non-abrasive cleaner. Always follow the cleaner manufacturer s instructions when using any cleaner. Always apply these cleaners when the griddle is cold and rub in the direction of the metal s grain. Griddle Surface Care (non-chromium surfaces) It takes very little time and effort to keep the griddle attractive and performing at top efficiency. If grease is permitted to accumulate, it will form a gummy cake and then carbonize into a hard substance which is extremely difficult to remove. To prevent this condition, the following suggestions for cleanliness should be followed: After each use, scrape the griddle with a scraper or flexible spatula to remove excess grease and food. A waste drawer is provided for the scrapings. If there is an accumulation of burned on grease and food, the griddle should be thoroughly scoured and re-seasoned. Use pumice or griddle stone while the griddle is warm. Do not use steel wool because of the danger of steel slivers getting into the food. Griddle Care (Chromium Surfaces) It takes very little time and effort to keep this Industrial Chromium griddle surface sparkling clean and performing at top efficiency. DO NOT allow grease to accumulate as it will carbonize and become difficult to remove. To prevent this condition the following cleaning suggestions should be followed:. Remove excess grease and food regularly with a (00mm) wide Razor Sharp type scraper and wipe surface with a damp cloth if desired.. Following the scraping, for end of the day cleaning, a damp cloth and a non-silicated, nonabrasive, non-chlorinated cleaner such as Bon-Ami may be used to wipe surface clean, followed by wiping with a clean wet cloth.. Follow steps and from Griddle Care (Non-Chromium Surfaces) above. CAUTION. Never use pumice, griddle stones, or abrasives on a chromium surface.. Never strike a chromium griddle surface with a sharp instrument or spatula edge.. Never use steel wool.. Never use commercial liquid grill cleaner on the griddle surface.. Abusing surface voids the warranty. KEEP WATER AND SOLUTIONS OUT OF CONTROLS. NEVER SPRAY OR HOSE CONTROL CONSOLE. WARNING CAUTION NOTICE: MOST CLEANERS ARE HARMFUL TO THE SKIN, EYES, MUCOUS MEMBRANES AND CLOTHING. PRECAUTIONS SHOULD BE TAKEN TO WEAR RUBBER GLOVES, GOGGLES OR FACE SHIELD AND PROTECTIVE CLOTHING. CAREFULLY READ THE WARNING AND FOLLOW THE DIRECTIONS ON THE LABEL OF THE CLEANER TO BE USED. Never leave a chlorine sanitizer in contact with stainless steel surfaces longer than 0 minutes. Longer contact can cause corrosion.

13 TROUBLESHOOTING Symptoms What follows is a chart of symptoms and possible causes to aid in diagnosing faults with the griddle. Refer to the Symptoms column to locate the type of failure then to the possible cause for the items to be checked. To test for a possible causes refer to the TEST section and locate the possible cause then refer to test to identify test procedures. SYMPTOM Whole Griddle will not heat One Section will not heat POSSIBLE CAUSE No Power to Griddle Failed Power switch Failed Transformer. Failed Power switch (for that section) Failed Probe Failed Circuit board Failed -position switch Failed contactor Failed Element. Product left on griddle too long Product Burning Product Under cooked Failed Probe Failed Circuit board Failed -position switch Product removed too soon Failed Probe Failed Circuit board Failed -position switch

14 TROUBLESHOOTING continued NOTICE: Service on this, or any other, LANG appliance must be performed by qualified personnel only. Consult your Lang Authorized Service Agent Directory or call the factory at --, or For the service agent nearest you. BOTH HIGH AND LOW VOLTAGES ARE PRESENT INSIDE THIS APPLIANCE WHEN THE UNIT IS PLUGGED/WIRED INTO A LIVE RECEPTACLE. BEFORE WARNING REPLACING ANY PARTS, DISCONNECT THE UNIT FROM THE ELECTRIC POWER SUPPLY. If an item on the list is followed by an asterisk (*), the work should be done by a factory authorized service representative. POSSIBLE CAUSE Product is cooked too long Failed Probe Failed Circuit board Failed Transformer Failed Contactor Failed Element TEST No test available, operational condition Check probe for proper resistance* Confirm that Circuit board is getting correct voltage and putting out correct voltage* Check both Primary and Secondary coils for correct voltage* Remove the wires from the contactor coil and check for continuity across the contactor coil connection* Ensure the contactor moveable points move freely up and down* Confirm that Elements are getting correct voltage and have continuity* CAUTION USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY LANG OR THEIR AUTHORIZED DISTRIBUTORS CAN CAUSE BODILY INJURY TO THE OPERATOR AND DAMAGE TO THE EQUIPMENT AND WILL VOID ALL WARRANTIES.

15 ELEMENT HOOKUP 0V 0V INSTALL JUMPER REMOVE JUMPER GRIDDLE ELEMENTS GRIDDLE PILOT LAMP CONTACTOR JUMPER TERMINAL BLOCK TEMP. CONTROL BOARD TOGGLE TRANSFORMER 0 PROBE L L L NOTE: 0 & HAVE TWO POWER SUPPLY CONNECTIONS 0 : CONN # USE LG CONN # USE LG : CONN # USE LG CONN # USE LG SERVICE CONNECTIONS DWN. BY : DLG DWN. DATE : -0-0 DESCRIPTION: W/D GRIDDLE 0/0VAC CAD FILE : FROM ACAD DWG. NO: - SHEET OF REV: B MODEL K.W. L-L L-L L-L TOTAL THREE PHASE L L,,,,,,, SINGLE PHASE L L L,,,,,,,,,,,,,, Note: LG LG. Add one more section for a single connection. Add two more sections for a 0. This wiring diagram shows / section for a model. Do not use more than contactors to one transformer GRIDDLE ELEMENTS GRIDDLE PILOT LAMP CONTACTOR JUMPER TERMINAL BLOCK TEMP. CONTROL BOARD TOGGLE TRANSFORMER 0 PROBE 0V NOTE: SOME AND ALL 0 & GRIDDLES HAVE TWO POWER SUPPLY CONNECTIONS : CONN # USE LG CONN # USE LG V 0 : CONN # USE LG CONN # USE LG : CONN # USE LG CONN # USE LG 0 L L L DWN. BY : SRC DWN. DATE : 0-- DESCRIPTION: LANG-GRIDDLE 0VAC SELECTRONIC CAD FILE :FROM ACAD DWG. NO: - SHEET OF REV: C

16 D R E V IS IO N S R E V D E S C R IP TIO N R E V B Y R E V D A TE C H K B Y C H K D A TE - E C O, IN ITIA L R E LE A S E, R E P LA C E D - D JS //00 A E C O R evis e w ire num bers to m atc h produc tion, add w ire nuts to m atc h produc tion D JS 0//00 B E C O 0. R em oved O vertem p S tats D JS /0/0 D Note:. Add one more section for a single connection LG- (S). Add two more sections for a LG-0 (0S). This wiring diagram shows / section for a LG- (S) model. Do not use more than contactors to one transformer 0 LG or S 0 LG or S 0 C GRIDDLE ELEMENTS C GRIDDLE PILOT LAMP CONTACTOR JUMPER TERMINAL BLOCK TEMP. CONTROL BOARD TOGGLE TRANSFORMER, CLASS 0 PROBE 0V NOTE: SOME LG (S) AND ALL LG0 (0S) & LG (S) HAVE TWO POWER SUPPLY CONNECTIONS B LG (S): CONN # USE LG (S) CONN # USE LG (S) LG0 (0S): CONN # USE LG (S) CONN # USE LG (S) LG (S): CONN # USE LG (S) CONN # USE LG (S) YEL V BLU B A AMP TOTAL SERVICE CONNECTIONS M odel L L L M odel Three P has e L L L,,,, 0,,,,, L L L 0 A UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. TOLERANCES ARE: DECIMALS ANGLES.X = ±.0 ±..XX = ±.0.XXX = ±.0 MATERIAL PART # : DWN. BY : DJS DWN. DATE : //0 REV. BY : REV. DATE : CHK. BY : DESCRIPTION: MATERIAL TYPE : LANG-GRIDDLE 0VAC SELECTRONIC BLANK DIMS. : CHK. DATE : X BLANK AREA: sq in CAD FILE : SHEET OF DWG. NO: M--W0 REV: B

17 GRIDDLE ELEMENTS GRIDDLE PILOT LAMP-0V CONTACTOR - GRIDDLE PWR CONNECT TERM BLK TEMP CONTROL BOARD TOGGLE TRANSFORMER, CL PROBE 0 OVERTEMP STAT - GRID TERMINAL BLOCK HOOD PILOT LAMP HOOD OVERTEMP STAT # FUSES CONTACTOR - HOOD TIMER PLUGS HOOD ELEMENTS HOOD TILT HOOD OVERTEMP STAT # 0 HOOD OVERTEMP STAT # CLAMSHELL PILOT LAMP-0V GRIDDLE PILOT LAMP-V SEE NOTES & STAR MANUFACTURING INTERNATIONAL INC. # 0 SUNNEN DRIVE ST. LOUIS, MO., USA THIS DRAWING CONTAINS INFORMATION CONFIDENTIAL TO STAR MFG. INT'L INC. NO REPRODUCTION OR DISCLOSURE OF ITS CONTENTS IS PERMITTED MATERIAL FINISH DR : DJS CK. DATE : TOLERANCE: UNLESS NOTED:.xxx ±.0 ANGLES SEE NOTES & 0//00 REVISIONS MODEL NO. PART NO. M--W TITLE W/D ' SELECTRONIC ELECT GRID W/ CSE HOODS - 0V REV. DATE/ECO DESCRIPTION OF CHANGE DR 0 0 0V R TRANSFORMER 0V V TRANSFORMER V GRIDDLE FIELD WIRING NOTE: THREE PHASE L -, L - L - 0 GRIDDLE FIELD WIRING NOTE: THREE PHASE L -, L -, L -, GRIDDLE RIGHT TO CONNECTION POINT A ON ND & RD HOOD CONTACTOR BOX CLAMSHELL HOOD NOTES:. FUSE BLOCK PAIR REQUIED FOR EVERY OR CLAMSHELL COMBINATION ON EACH POWER CONNECTION.. OVERTEMP STATS ARE LOCATED ON THE UNDERSIDE OF THE GRIDDLE PLATE.. SEE TABLE FOR ITEM, & 0 USAGE DASHED COMPONENTS ARE REQURED ONLY WHEN HOODS ARE USED ON ONE POWER CONNECTION.. CLAMSHELL VOLTAGE MAY BE DIFFERENT THAN GRIDDLE VOLTAGE. SEE CLAMSHELL NAMEPLATE FOR PROPER VOLTAGE FOR CLAMSHELL. HOOD # HOOD # TO ND HOOD TILT TO RD HOOD TILT TO CONNECTION POINT B ON ND HOOD CONTACTOR BOX TO CONNECTION POINT C ON ND HOOD CONTACTOR BOX GRIDDLE LEFT TO CONNECTION POINT B ON RD HOOD CONTACTOR BOX TO CONNECTION POINT C ON RD HOOD CONTACTOR BOX CLAMSHELL HOOD BOX CONTACTOR L -, L -, CONTACTOR BOX TO CONNECTION POINT B ON ND HOOD CONTACTOR BOX TO CONNECTION POINT C ON ND HOOD CONTACTOR BOX TO CONNECTION POINT A ON ND HOOD CONTACTOR BOX 0 CLAMSHELL FIELD WIRING NOTE OR PHASE THREE PHASE L - L -, L - TO ND HOOD TILT B C A B C A 0 0 BLU/W R/W R/W GRIDDLE WIRES ONLY TO TERMINAL GRIDDLE WIRES ONLY TO TERMINAL BLOCK BLU/W UP DOWN OVERTEMP STAT ITEM # HOOD # BLOCK HOOD # TOP VIEW OF GRIDDLE OVERTEMP STAT ITEM # HOOD # FRONT OF GRIDDLE L - L - OVERTEMP STAT ITEM #0,0,0,0,0 0,,0,0,0 CLAMSHELL FIELD WIRING NOTE SINGLE PHASE TABLE HOOD # USE OVERTEMP STAT ITEM # 0 0,,,,,0,,0,,,,,,,,,,,,,, UP DOWN TABLE HOOD # USE OVERTEMP STAT ITEM #,,,0,,,0,,,0,,,0,,,,0,,,,0 ALL OTHER COMBINATIONS, & 0

18 0 SOME ITEMS ARE INCLUDED FOR ILLUSTRATIVE PURPOSES AND IN CERTAIN INSTANCES MAY NOT BE AVAILABLE For individual parts SEE DETAIL A This drawing contains information confidential to Star Manufacturing International, Inc. No reproduction or disclosure of it's contents is permitted. Model: S - S Selectronic Control Electric Griddle LG Electric Griddle Accu-Temp Control SK Rev. C //

19 PARTS LIST July, 0, Rev H Model: S, S-0V, SHE, SCHE, Selectronic Electric Griddle FIG NO. PART NO. QTY DESCRIPTION APPLICATION K-XL-- PLATE ASY SEL. GRV S, S-0V K-XL-- PLTEASY SEL.GRVW/XLH SHE K-XL--C PLT ASSY SEL. GRV CHR SCHE K-XL--W PLATE ASSY SEL.. GRV SC E-00- TEMP PROBE SEL LG GRIDDLE S, S-0V, SHE K-XL- BUCKET SLIDE ASSY ALL K-LG-BODY- BLANK BODY LG & XL FT ALL A-Z0 FOOT, DIE CAST S, S-0V, SHE A-00-0 LEG W/BOLT DOWN ADJ MARINE K-LGPS-C PNEL XL-LG SEL 0/0V S K-LGPS-C-W PNEL SEL 0/0V W/CSE SHE K-LGPS-U PNEL XL-LG SEL 0V S-0V K-00-0 GREASE DRAWER LG/XL ALL K-XL- PROBE HOLDER SELECTRONIC ALL 0 K-XL- ELEMENT PAN ASSEMLBY ALL H-XL- ELEMENT PAN INSULATION ALL K-XL- ELEMENT PAN Z ASSEMBLY ALL N-00- ELE GRD 0/0V.KW/KW S, S-0V & VM, SHE, SCHE N-00- ELMNT GRID 0V W S-0V, SHE-0V N-00- ELE GRD 0V W XL/LG S-0VM N-00-0 ELMNT GRID 0V W S, S-0VM, S-0V, SHE, SCHE NI K-00- GRAB BARASSY XL-LG MARINE NI E TRM STRP POLE 0A 00V S, S-0V, SHE NI E TRM BLOCK PLELRGE AMP S, S-0V, SHE NI E-00-0 TERM STRP POLE W/PUSH S, S-0V, SHE NI P GROOVED GRIDDLE CLEANING ALL NI P GRVED GRDLE BRUSH REPL ALL NI P GRVED GRDLE BRUSH REPL ALL NI P-000- GRIDDLE SCRAPER CROME UNITS NI P RE-FILL REPLACEMENTS CROME UNITS NI P-000- BOM AMI CLEANER CROME UNITS NI P PALMYRA BRUSH CROME UNITS IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE INCLUDE MODEL AND SERIAL NUMBER OF Some items are included for illustrative purposes only and in certain instances may not be available.

20 PARTS LIST July, 0, Rev H Model No: S, S-SC, SHE, SCHE, S-0VM, S-0V Selectronic Electric Griddle FIG NO PART NO. QTY DESCRIPTION APPLICATION K-XL-- PLATE ASY SEL. GRV S K-XL--W PLATE ASY SEL. GRV CHR SC K-XL-- PLATE ASY SEL. GRV SHE K-XL--C PLATE ASY SEL. GRV CHR SCHE K-XL-- PLATE ASY SEL REAR SR E-00- TEMP PROBE SEL LG GRIDDLE ALL K-XL- BUCKET SLIDE ASSY ALL K-XL--0 BKT SLIDE ASSY REAR GUTER SR K-LG-BODY- BLANK BODY LG & XL FT ALL K-LG-BODY-WB BLANK BODY REAR GUTTER SR A-Z0 FOOT, DIE CAST S, 0V A-00-0 LEG W/BOLT DOWN ADJ MARINE A-00 LEG,. METAL S-SC K-LGPS-C PANEL XL-LG SEL 0/0V S K-LGPS-CWB PNELXL-LG SEL 0/0V SR K-LGPS-K PANEL CL-LG SEL 0V S-0VM K-LGPS-U PANEL XL-LG SEL 0V S-0V K-00- ACCESS PANEL ASSY S, SB, SC K-XL-- GREASE BUCKET ASSY S/S ALL K-XL--0 GREASE BKT ASY REAR GUTER SR K-XL- PROBE HOLDER SELECTRONIC ALL 0 K-XL- ELEMENT PAN ASSEMLBY ALL H-XL- ELEMENT PAN INSULATION ALL K-XL- ELEMENT PAN Z ASSEMBLY ALL N-00- ELE GRD 0/0V.KW/KW S N-00-0 ELMNT GRID 0V W S-0V, 0VM N-00- ELMNT GRID 0V W S-0V, SHE-0V N-00- ELE GRD 0V W XL/LG S-0VM N-00-0 ELMNT GRID 0V W S K-00- GRAB BARASSY XL-LG SR, MARINE NI E TRM STRP POLE 0A 00V S, 0V NI E TRM STRP POLE 0A 00V S, 0V NI P GROOVED GRIDDLE CLEANING ALL NI P GRVED GRDLE BRUSH REPL ALL NI P GRVED GRDLE BRUSH REPL ALL NI P-000- GRIDDLE SCRAPER CROME UNITS NI P RE-FILL REPLACEMENTS CROME UNITS NI P-000- BOM AMI CLEANER CROME UNITS NI P PALMYRA BRUSH CROME UNITS IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE INCLUDE MODEL AND SERIAL NUMBER OF Some items are included for illustrative purposes only and in certain instances may not be available. 0

21 PARTS LIST July, 0, Rev H Model No: S, S-0V, S-SC, S-WB Selectronic Electric Griddle FIG NO PART NO. QTY DESCRIPTION APPLICATION K-XL-- PLATE ASY SEL REAR GUTR S-WB, SR K-XL-- PLATE ASY SEL. GRV S K-XL-- PLTEASY SEL.GRVW/XLH SHE-0V E-00- TEMP PROBE SEL LG GRIDDLE ALL K-XL- BUCKET SLIDE SUPPORT S, S-SC K-XL--0 BUCKET WRAP REAR GUTTER S-WB, SR K-XL-- BODY ASSEMBLY XL ALL A-Z0 FOOT, DIE CAST S, S-SC A-00-0 LEG W/BOLT DOWN ADJ MARINE A-00 LEG,. METAL S-SC K-LGPS-CWB- PNL LG-S 0/0V WB BDY S-WB, SR K-LGPS-C PANEL XL-LG SEL 0/0V S K-LGPS-U PANEL XL-LG SEL 0V S-0V, S-SC K-LGPS-U-W PANEL XL ASSY-LG SEL SHE-0V K-XL-- GREASE BUCKET ASSY S/S S K-XL--0 GREASE BKT ASY REAR GUTER S-WB, SR K-XL- PROBE HOLDER SELECTRONIC ALL 0 K-XL- ELEMENT PAN ASSEMLBY ALL H-XL- ELEMENT PAN INSULATION ALL K-XL- ELEMENT PAN Z ASSEMBLY ALL N-00- ELE GRD 0/0V.KW/KW S N-00- ELEM GRID 0V W S-0V N-00- ELMNT GRID 0V W S-0V N-00-0 ELMNT GRID 0V W S NI K-00- GRAB BAR ASSY XL-LG S-WB, SR, MARINE NI E TRM STRP POLE 0A 00V S-WB, SR NI E TRM STRP POLE 0A 00V S NI E TRM BLOCK PLELRGE AMP S NI E TRM BLOCK PLELRGE AMP S-WB, SR NI E-00-0 TERM STRP POLE W/PUSH S, S-SC NI E-00-0 TERM STRP POLE W/PUSH S-WB, SR NI P GROOVED GRIDDLE CLEANING ALL NI P GRVED GRDLE BRUSH REPL ALL NI P GRVED GRDLE BRUSH REPL ALL NI P-000- GRIDDLE SCRAPER CROME UNITS NI P RE-FILL REPLACEMENTS CROME UNITS NI P-000- BOM AMI CLEANER CROME UNITS NI P PALMYRA BRUSH CROME UNITS IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE INCLUDE MODEL AND SERIAL NUMBER OF Some items are included for illustrative purposes only and in certain instances may not be available.

22 PARTS LIST January 0, 0, Rev I Model No: 0S, 0S-0V, 0S-SC, 0S-WB, 0SHE Selectronic Electric Griddle FIG NO PART NO. QTY DESCRIPTION APPLICATION K-XL-- PLATE ASY SEL REAR GUTR 0S-WB, 0SR K-XL-- PLATE ASY SEL. GRV 0S K-XL-- PLATE ASY GRV W/ XLH 0SHE K-XL--- PLATE ASY SEL..GRV 0SCHE E-00- TEMP PROBE SEL LG GRIDDLE 0S,0S-SC, 0SHE K-XL- BUCKET SLIDE SUPPORT 0S K-XL--0 BUCKET WRAP REAR GUTTER 0S-WB, 0SR K-LG-BODY- BLANK BODY LG & XL FT K-LG-BODY- BLANK BODY LG & XL FT ALL A-Z0 FOOT, DIE CAST 0S,0S-SC, 0SHE A-00-0 LEG W/BOLT DOWN ADJ MARINE A-00 LEG,. METAL 0S-SC K-LGPS-C PANEL XL-LG SEL 0/0V 0S, 0S-SC, 0SHE K-LGPS-CWB PANEL XL-LG SEL 0/0V WB 0S-WB, 0SR K-LGPS-U PANEL XL-LG SEL 0V 0S-0V K-LGPS-C PANEL XL-LG SEL 0/0V 0S, 0S-SC K-LGPS-U PANEL XL-LG SEL 0V 0S-0V K-00- ACCESS PANEL ASSY 0S, 0S-M, 0S-SC, 0SHE, 0SB K-XL-- GREASE BUCKET ASSY S/S 0S, 0SHE K-XL--0 GREASE BKT ASY REAR GUTER 0S-WB, 0SR K-XL- PROBE HOLDER SELECTRONIC ALL 0 K-XL- ELEMENT PAN ASSEMLBY ALL H-XL- ELEMENT PAN INSULATION ALL K-XL- ELEMENT PAN Z ASSEMBLY ALL N-00- ELE GRD 0/0V.KW/KW 0S, 0SHE N-00- ELMNT GRID 0V W 0S-0V, 0SHE-0V N-00-0 ELMNT GRID 0V W 0S, 0SHE K-00- GRAB BARASSY XL-LG MARINE NI E TRM STRP POLE 0A 00V 0S, 0SHE NI E TRM STRP POLE 0A 00V 0S, 0SHE NI E TRM BLOCK PLELRGE AMP 0S, 0SHE NI E-00-0 TERM STRP POLE W/PUSH 0S, 0SHE NI E-00-0 TRM STRP POLE W/PUSH 0S, 0SHE NI P GROOVED GRIDDLE CLEANING NI P GRVED GRDLE BRUSH REPL NI P GRVED GRDLE BRUSH REPL NI K-00- GRAB BAR ASSY XL-LG 0S-WB, 0SR NI P-000- GRIDDLE SCRAPER CROME UNITS NI P RE-FILL REPLACEMENTS CROME UNITS NI P-000- BOM AMI CLEANER CROME UNITS NI P PALMYRA BRUSH CROME UNITS IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE INCLUDE MODEL AND SERIAL NUMBER OF Some items are included for illustrative purposes only and in certain instances may not be available.

23 PARTS LIST January 0, 0, Rev I Model No: S, S-0V, S-SC, S-0VM Selectronic Electric Griddle FIG NO PART NO. QTY DESCRIPTION APPLICATION K-XL-- PLATE ASY SEL. GRV ALL E-00- TEMP PROBE SEL LG GRIDDLE ALL K-XL- BUCKET SLIDE SUPPORT ALL K-XL-- BODY ASSEMBLY XL ALL A-Z0 FOOT, DIE CAST S A-00-0 LEG W/BOLT DOWN ADJ MARINE A-00 LEG,. METAL S-SC K-LGPS-C PANEL XL-LG SEL 0/0V S, S-SC K-LGPS-U PANEL XL-LG SEL 0V S-0V K-00- ACCESS PANEL ASSY S, S-CP, SB, SM K-XL-- GREASE BUCKET ASSY S/S ALL K-XL- PROBE HOLDER SELECTRONIC ALL 0 K-XL- ELEMENT PAN ASSEMLBY ALL H-XL- ELEMENT PAN INSULATION ALL K-XL- ELEMENT PAN Z ASSEMBLY ALL N-00- ELE GRD 0/0V.KW/KW S N-00- ELMNT GRID 0V W S-0V, S-0VM N-00- ELE GRD 0V W XL/LG S-0VM N-00-0 ELMNT GRID 0V W S K-00- GRAB BARASSY XL-LG MARINE K-XL-- PANEL COVER ASSY - CP S-CP NI E TRM STRP POLE 0A 00V S NI E TRM BLOCK PLELRGE AMP S NI E-00-0 TRM STRP POLE W/PUSH S NI P GROOVED GRIDDLE CLEANING NI P GRVED GRDLE BRUSH REPL NI P-000- GRIDDLE SCRAPER CROME UNITS NI P RE-FILL REPLACEMENTS CROME UNITS NI P-000- BOM AMI CLEANER CROME UNITS NI P PALMYRA BRUSH CROME UNITS IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE INCLUDE MODEL AND SERIAL NUMBER OF Some items are included for illustrative purposes only and in certain instances may not be available.

24 0 0 DETAIL A Control Panel Assembly (LPGS-C shown) SK0 Rev. B //0

25 PARTS LIST January 0, 0, Rev I Detail A: Control Panel Assembly, Selectronic Electric Griddle Model Number Qty Description Control Panel Assembly S, S-0VM PNEL XL-LG SEL 0/0V LGPS-C-W, LGPSE-C (marine) S-0V, S-0VM PNEL XL-LG SEL 0V LGPS-U-W, LPGS-U (marine) SHE, SCHE PNEL SEL 0/0V W/CSE LGPS-C-W S PANEL XL-LG SEL 0/0V LGPS-C-W S-SC PANEL XL-LG SEL 0/0V LGPS-C-W S-0VM PANEL CL-LG SEL 0V LGPS-K S-0V, SC-0V PANEL XL-LG SEL 0V LGPS-U SHE PNEL SEL 0/0V W/CSE LGPS-C-W S, S-SC PANEL XL-LG SEL 0/0V LGPS-C S-0V PANEL XL-LG SEL LGPS-K S-0V, S-0/0VM PANEL XL-LG SEL 0V LGPS-U SHE-0V PANEL SL ASSY-LG SEL LGPS-U-W S-WB, SR PNL LG-S 0/0V WB BDY LGPS-CWB- 0S, 0S-SC, 0SHE PANEL XL-LG SEL 0/0V LGPS-C-W 0S, 0S-SC, 0SHE PANEL XL-LG SEL 0/0V LGPS-C-W 0S-0V, 0SHE-0V PANEL XL-LG SEL 0V LGPS-U-W 0S-0V, 0SHE-0V PANEL XL-LG SEL 0V LGPS-U-W 0S-WB, 0SR PANEL XL-LG SEL 0/0V WB LGPS-CWB S, S-SC PANEL XL-LG SEL 0/0V LGPS-C-W S-0V PANEL XL-LG SEL 0V LGPS-U-W Control Panel Parts Listing Fig No Part Number Qty Description Control Panel Assembly K-XL--0 ELECT BOX ASY LG SEL LGPS-C, LGPS-U K-XL--00 ELECT BOX ASY LG SEL LGPS-CWB- K-XL--00 ELECT BOX ASY LG SEL LGPS-CWB- K-XL--0 ELECT BOX ASY LG SEL LGPS-CWB K-XL--0-W ELE BOX ASSY SEL W/CSE LGPS-C-W K-XL--0 ELECT BOX ASY LG SEL LGPS-C, LGPS-U, LGPS-K K-XL--0 ELECT BOX ASY SEL W/CSE LGPS-C-W K-XL-- ELECT BOX ASY LG SELECT LGPS-C, LGPS-U K-XL-- ELEC BOX ASSY SEL LGPS-U-W LGPS-C, LGPS-U C-00-0 SCRW SM PLT 0 X. PHLSL LGPS-C, LGPS-U, LGPS-C-W, LGPS-K LGPS-C, LGPS-U, LGPS-U-W, LGPS-K K-00-0 SNAP BUSH / SB- LGPS-C, LGPS-U, LGPS-K LGPS-C, LGPS-U E-00-0 SWT PLATE ON/OFF LGPS-C, LGPS-U, LGPS-C-W, LGPS-K LGPS-C, LGPS-U, LGPS-U-W, LGPS-K LGPS-C, LGPS-U E-00-0 SWT TOG ON-ON DPDT BLK LGPS-C, LGPS-U, LGPS-K LGPS-C, LGPS-U, LGPS-U-W, LGPS-K LGPS-C, LGPS-U R-00- KNB BLK /BUSHSETSCW@0 LGPS-C, LGPS-U, LGPS-K LGPS-C, LGPS-U, LGPS-K LGPS-C, LGPS-U M-00- PNLLBL SELCT SWTDIAL 0o LGPS-C, LGPS-U LGPS-C, LGPS-U, LGPS-K

26 PARTS LIST January 0, 0, Rev I Fig No Part Number Qty Description Control Panel Assembly LGPS-C, LGPS-U E-00- SWTCB-0oFW/00- LGPS-C, LGPS-U, LGPS-K LGPS-C, LGPS-U, LGPS-U-W, LGPS-K LGPS-C J-0-0 PILOT LT 0V LEAD BLK LGPS-C, LGPS-U LGPS-C LGPS-U J-0-0 PILOT LT 0V LEAD BLK LGPS-U, LGPS-K LGPS-U, LGPS-U-W, LGPS-K Y-0-0- PILOT LT V W/TIN CLIP LGPS-U, LGPS-U, LGPS-U-W, LGPS-K LGPS-C, LGPS-U 0 E-00-0 CONTC POLE 0A VAC LGPS-C, LGPS-U, LGPS-K LGPS-C, LGPS-U, LGPS-U-W, LGPS-K K-XL-- CPMTACT. MNT PLT SEL LGPS-C, LGPS-U K-XL-- CNTR MT PLT SLCTRNC LG LGPS-C, LGPS-U, LGPS-K K-XL-- CONT. MNT PLT SELEC LG LGPS-C, LGPS-U, LGPS-K LGPS-U K-00-0 SNAP BUSH / SB0-0 LGPS-C, LGPS-U, LGPS-K LGPS-C, LGPS-U, LGPS-K LGPS-C, LGPS-U E-00-W CIRBD SI TEMP CNTRL NO LGPS-C, LGPS-U, LGPS-K LGPS-C, LGPS-U, LGPS-U-W, LGPS-K LGPS-C, LGPS-U K-00-0 SPACER SUPPORT /LG LGPS-C, LGPS-U, LGPS-K LGPS-C, LGPS-U, LGPS-K K-XL--0 CIRC BRD MNT LGPS-C, LGPS-U, LGPS-K K-XL-- CIRCUIT BOARD MOUNT LGPS-C, LGPS-U K-XL-- CIRC BOARD MOUNT LGPS-C, LGPS-U C-00-0 LGPS-C, LGPS-U, LGPS-C, LGPS-C-W, LGPS-U SCRW PHD ST -X. PLTD LGPS-C, LGPS-U, LGPS-U-W K-XL-0- ELECT BOX CVER SEL LGPS-U-W K-XL-- ELECT BOX CVER SPT SEL LGPS-C, LGPS-U, LGPS-K K-XL-- ELECT BOX CVER SPT SEL LGPS-C, LGPS-U, LGPS-K K-XL-- ELECT BOX CVER SPT SEL LGPS-C, LGPS-U E-00-0 XFORMR0-0-0/V0VA LGPS-C, LGPS-C, LGPS-C E-00- XFORMR 0/VAC 0VA U/L LGPS-K LGPS-U, LGPS-U-W, LGPS-U, LGPS-U-W, LGPS-U, E-00-W XFRNR 0V/V CL 0VA LGPS-U-W C-00- SCRW MS PLT 0- X. ALL 0 C-00- NUT HEX 0- PLTD ALL NI E-00-0 TRM STRP POLE W/PUSH LGPS-K E-00-0 TRM STRP POLE W/PUSH LGPS-K NI T-00- STAT FXD 00 F DEG OPEN LGPS-C, LGPS-C-, LGPS-C-W, LGPS-CWB, LGPS- CWB-, LGPS-U NI T-00- STAT FXD 00 F DEG OPEN LGPS-C, LGPS-C-W, LGPS-CWB, LGPS-U, LGPS-K NI T-00- STAT FXD 00 F DEG OPEN LGPS-C, LGPSA-C-W, LGPS-U, LGPS-U-W

27

28 STAR INTERNATIONAL HOLDINGS INC. COMPANY Star - Holman - Lang - Wells - Bloomfield - Toastmaster 0 Sunnen Drive, St. Louis, MO U.S.A.

THERMOSTATIC DROP-IN ELECTRIC GRIDDLE 136TDI, 148TDI, 160TDI

THERMOSTATIC DROP-IN ELECTRIC GRIDDLE 136TDI, 148TDI, 160TDI THERMOSTATIC DROP-IN ELECTRIC GRIDDLE 6TDI, 8TDI, 60TDI Installation and Operation Instructions M-W6 Rev. D /7/ IL7 60TDI SAFETY SYMBOL These symbols are intended to alert the user to the presence of important

More information

Electric Cruise Line Single Broiler w/ Cabinet Base CLB V CLB V

Electric Cruise Line Single Broiler w/ Cabinet Base CLB V CLB V Electric Cruise Line Single Broiler w/ Cabinet Base CLB36-1-400V CLB36-1-440V Installation and Operation Instructions 2M-W1256 Rev. A 1/2/2009 CLB36-1-440V SAFETY SYMBOL These symbols are intended to alert

More information

Electric Cruise Line Double Broiler w/ Oven Base CLB36S-2-440V CL36B2OLF440

Electric Cruise Line Double Broiler w/ Oven Base CLB36S-2-440V CL36B2OLF440 Electric Cruise Line Double Broiler w/ Oven Base CLB36S-2-440V CL36B2OLF440 Installation and Operation Instructions 2M-W1281 Rev. B 10/26/2011 CLB36S-2-440V SAFETY SYMBOL These symbols are intended to

More information

Installation, Operation, Maintenance, & Troubleshooting Model: CLS36-440V Electric Cruise Line Salamander Serial:

Installation, Operation, Maintenance, & Troubleshooting Model: CLS36-440V Electric Cruise Line Salamander Serial: Installation, Operation, Maintenance, & Troubleshooting Model: CLS36-440V Electric Cruise Line Salamander Serial: Lang Manufacturing Company 10 Sunnen Dr, St. Louis, MO 63143 Part No: 2M-W1257, Rev. -

More information

Installation, Operation, Maintenance, & Troubleshooting Model: CLG-36-S Electric Cruise Line Griddle Serial:

Installation, Operation, Maintenance, & Troubleshooting Model: CLG-36-S Electric Cruise Line Griddle Serial: Installation, Operation, Maintenance, & Troubleshooting Model: CLG-36-S Electric Cruise Line Griddle Serial: Lang Manufacturing Company 6500 Merrill Creek Parkway Everett, WA 98203 Phone: 425-349-2400

More information

Installation, Operation, Maintenance and Service Instructions. Fryer Model: 130F

Installation, Operation, Maintenance and Service Instructions. Fryer Model: 130F Installation, Operation, Maintenance and Service Instructions Fryer Model: 130F Star Manufacturing International 10 Sunnen Drive St. Louis, MO.63143-3800 Part Number: 2M-W478 Ph: 314-781-2777 Fax: 314-781-2714

More information

Installation, Operation, & Maintenance Model: MM24, MM36 and MM48, Electric Cheese Melter

Installation, Operation, & Maintenance Model: MM24, MM36 and MM48, Electric Cheese Melter Installation, Operation, & Maintenance Model: MM24, MM36 and MM48, Electric Cheese Melter THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED

More information

Installation, Operation, & Maintenance. Electric Cheese Melter. Model: 124CM, 136CM and 148CM

Installation, Operation, & Maintenance. Electric Cheese Melter. Model: 124CM, 136CM and 148CM Installation, Operation, & Maintenance Electric Cheese Melter Model: 124CM, 136CM and 148CM Lang Manufacturing 10 Sunnen Drive St. Louis, MO 63143 Rev. B Phone: (314) 678-6315 Fax: (314) 781-2714 Part

More information

Installation, Operation, Maintenance, & Troubleshooting Model: EQS-AP Quarter Size Convection Oven

Installation, Operation, Maintenance, & Troubleshooting Model: EQS-AP Quarter Size Convection Oven Installation, Operation, Maintenance, & Troubleshooting Model: EQS-AP Quarter Size Convection Oven Lang Manufacturing Company 6500 Merrill Creek Parkway Everett, WA 98203 Part Number: 60800-34 Phone: 425-349-2400

More information

ELECTRIC CLAMSHELL CSE12-208VCD, CSE12A-1, CSE12A-2

ELECTRIC CLAMSHELL CSE12-208VCD, CSE12A-1, CSE12A-2 ELECTRIC CLAMSHELL CSE12-208VCD, CSE12A-1, CSE12A-2 Glass Surface CSE12A-1G thru CSE12A-6G Contact Clam CCSE12A-208 Installation and Operation Instructions 2M-W363 Rev. F 3/19/2015 CSE12A SAFETY SYMBOL

More information

ELECTRIC GRIDDLES TMGE24, TMGE36, TMGE48. Installation and Operation Instructions 2M-Z12971 Rev. - Oct. 1, 2009 MODEL TMGE36 IL1880

ELECTRIC GRIDDLES TMGE24, TMGE36, TMGE48. Installation and Operation Instructions 2M-Z12971 Rev. - Oct. 1, 2009 MODEL TMGE36 IL1880 ELECTRIC GRIDDLES MODEL,, TMGE48 Installation and Operation Instructions M-Z1971 Rev. - Oct. 1, 009 IL1880 CAUTION SAFETY SYMBOLS These symbols are intended to alert the user to the presence of important

More information

STAR-MAX PROPANE GAS GRIDDLE

STAR-MAX PROPANE GAS GRIDDLE Star Manufacturing International Inc. 10 Sunnen Drive St. Louis, MO 63143 Phone: (314) 781-2777 Fax: (314) 781-3636 Installation and Operating Instructions 2M-Z3793 Rev. B 3/28/03 STAR-MAX PROPANE GAS

More information

STAR-MAX GAS GRIDDLES MODELS 615MA 624MA 636MA 648MA 615TA 624TA 636TA 648TA 624TSPA 636TSPA 648TSPA

STAR-MAX GAS GRIDDLES MODELS 615MA 624MA 636MA 648MA 615TA 624TA 636TA 648TA 624TSPA 636TSPA 648TSPA Star Manufacturing International Inc. 10 Sunnen Drive St. Louis, MO 63143 Phone: (314) 781-2777 Fax: (314) 781-3636 Installation and Operating Instructions 2M-Z1351 Rev. B 4/23/04 STAR-MAX GAS GRIDDLES

More information

Installation, Operation, Maintenance, & Troubleshooting Model: R60S Standard Bake Oven Range

Installation, Operation, Maintenance, & Troubleshooting Model: R60S Standard Bake Oven Range Installation, Operation, Maintenance, & Troubleshooting Model: R60S Standard Bake Oven Range Star Manufacturing International 10 Sunnen Drive St. Louis, MO.63143-3800 Part Number: 2M-W822 Ph: 314-781-2777

More information

Installation, Operation, & Maintenance Model: 236CM, 248CM, Gas Infrared Cheesemelter

Installation, Operation, & Maintenance Model: 236CM, 248CM, Gas Infrared Cheesemelter Installation, Operation, & Maintenance Model: 236CM, 248CM, Gas Infrared Cheesemelter Lang Manufacturing 10 Sunnen Drive, St. Louis, MO 63143 Part # 2M-60803-02 Phone:314-678-6315 Fax: 314-781-2714 Rev.

More information

Installation, Operation, and Maintenance Instructions with Troubleshooting Electric Full Size Economy Convection Oven Models: FCOFL-AT (Lower)

Installation, Operation, and Maintenance Instructions with Troubleshooting Electric Full Size Economy Convection Oven Models: FCOFL-AT (Lower) Installation, Operation, and Maintenance Instructions with Troubleshooting Electric Full Size Economy Convection Oven Models: FCOFL-AT (Lower) FCOF-AT (Upper) Lang Manufacturing 10 Sunnen Drive St. Louis,

More information

Installation, Operation, & Maintenance Model: PPP, Electric Air Door Pizza Oven

Installation, Operation, & Maintenance Model: PPP, Electric Air Door Pizza Oven Installation, Operation, & Maintenance Model: PPP, Electric Air Door Pizza Oven Lang Manufacturing Company 6500 Merrill Creek Parkway Everett, WA 98203 Part # Phone: 425-349-2400 Fax: 425-349-2733 Rev.

More information

Model: CSG24. Installation. Operation. Maintenance. Troubleshooting. Add-on Clamshell Hood

Model: CSG24. Installation. Operation. Maintenance. Troubleshooting. Add-on Clamshell Hood Installation Operation Maintenance Troubleshooting Model: CSG24 Add-on Clamshell Hood Star Manufacturing International 0 Sunnen Drive St. Louis, MO 6343 Part Number: 2M-W36 Phone: 800-438-5264 Fax: 34-78-274

More information

ULTRA-MAX GAS RADIANT CHARBROILER. ULTRA-MAX GAS LAVA ROCK CHARBROILER MODELS 8024CBB, 8036CBB, 8048CBB, 8060CBB, and 8072CBB

ULTRA-MAX GAS RADIANT CHARBROILER. ULTRA-MAX GAS LAVA ROCK CHARBROILER MODELS 8024CBB, 8036CBB, 8048CBB, 8060CBB, and 8072CBB Star Manufacturing International Inc. 10 Sunnen Drive St. Louis, MO 63143 Phone: (314) 678-6303 Fax: (314) 781-2714 Installation and Operating Instructions 2M-Z20327 Rev. A 10/05/15 ULTRA-MAX GAS RADIANT

More information

TM... TECHNICAL MANUAL. Fryer, Deep-Fat, Electric w/solid State Controls NSN:

TM... TECHNICAL MANUAL. Fryer, Deep-Fat, Electric w/solid State Controls NSN: TM... TECHNICAL MANUAL MODEL USN-50 150F-440VMN DESCRIPTION Fryer, Deep-Fat, Electric w/solid State Controls 440 Volt, 60 HZ, 3 Phase NSN: Star Manufacturing International 10 Sunnen Drive St. Louis, MO.63143-3800

More information

Electric Griddle. Owner s Manual

Electric Griddle. Owner s Manual Electric Griddle Owner s Manual Models T, T, T, 0T, T, TC, TC, TC, 0TC, TC, S, S, S, 0S, S, SC, SC, SC, 0SC, SC This manual includes material related to installation, use, cleaning, and care. Exploded

More information

REFRIGERATED CONDIMENT RAIL

REFRIGERATED CONDIMENT RAIL REFRIGERATED CONDIMENT RAIL MODEL RCR-4 Installation and Operation Instructions 2M-Z19984 Rev. - 2/13/15 RCR-4 SAFETY SYMBOL These symbols are intended to alert the user to the presence of important operating

More information

BROIL-O-DOG MODEL 174CBA, 174SBA 175CBA, 175SBA. Installation and Operation Instructions 2M-Z3755 Rev. J 10/26/11 175CBA.

BROIL-O-DOG MODEL 174CBA, 174SBA 175CBA, 175SBA. Installation and Operation Instructions 2M-Z3755 Rev. J 10/26/11 175CBA. BROIL-O-DOG MODEL 174CBA, 174SBA 175CBA, 175SBA Installation and Operation Instructions 2M-Z3755 Rev. J 10/26/11 175CBA (120V Only) SAFETY SYMBOL These symbols are intended to alert the user to the presence

More information

ELECTRIC GRIDDLES MODELS CHROME MODELS 724TA, 736TA, 748TA, 760TA, 772TA 724TCHSA, 736TCHSA, 748TCHSA, 760TCHSA, 772TCHSA

ELECTRIC GRIDDLES MODELS CHROME MODELS 724TA, 736TA, 748TA, 760TA, 772TA 724TCHSA, 736TCHSA, 748TCHSA, 760TCHSA, 772TCHSA IL ELECTRIC GRIDDLES MODELS 7TA, 7TA, 78TA, 70TA, 77TA CHROME MODELS 7TCHSA, 7TCHSA, 78TCHSA, 70TCHSA, 77TCHSA 7TA Installation and Operation Instructions M-Z Rev. A // MODELS 70TA- & 77TA- Not approved

More information

HOT FOOD HUMIDITY CABINET

HOT FOOD HUMIDITY CABINET HOT FOOD HUMIDITY CABINET MODEL HFD- Installation and Operation Instructions M-Z Rev. L // HFD- SAFETY SYMBOL These symbols are intended to alert the user to the presence of important operating and maintenance

More information

ELECTRIC GRIDDLES MODELS CHROME MODELS 724TA, 736TA, 748TA, 760TA, 772TA 724TCHSA, 736TCHSA, 748TCHSA, 760TCHSA, 772TCHSA

ELECTRIC GRIDDLES MODELS CHROME MODELS 724TA, 736TA, 748TA, 760TA, 772TA 724TCHSA, 736TCHSA, 748TCHSA, 760TCHSA, 772TCHSA IL ELECTRIC GRIDDLES MODELS 7TA, 7TA, 78TA, 70TA, 77TA CHROME MODELS 7TCHSA, 7TCHSA, 78TCHSA, 70TCHSA, 77TCHSA 7TA Installation and Operation Instructions M-Z Rev. A // MODELS 70TA- & 77TA- Not approved

More information

CONVEYOR TOASTER MODEL QCS QCS Installation and Operation Instructions 2M-HG0657 Rev. D 6/13/05

CONVEYOR TOASTER MODEL QCS QCS Installation and Operation Instructions 2M-HG0657 Rev. D 6/13/05 CONVEYOR TOASTER MODEL QCS-2-800 QCS-3-1000 Installation and Operation Instructions 2M-HG0657 Rev. D 6/13/05 SAFETY SYMBOLS These symbols are intended to alert the user to the presence of important operating

More information

SHIPBOARD ELECTRIC CONVECTION OVEN ECOD-AT, ECODL-AT ECOF-AT, ECOFL-AT

SHIPBOARD ELECTRIC CONVECTION OVEN ECOD-AT, ECODL-AT ECOF-AT, ECOFL-AT SHIPBOARD ELECTRIC CONVECTION OVEN ECOD-AT, ECODL-AT ECOF-AT, ECOFL-AT Installation and Operation Instructions 2M-W483 Rev. E 3/8/3 ECOF-AT SAFETY SYMBOL These symbols are intended to alert the user to

More information

GAS CHARBROILER. Installation and Operation Instructions

GAS CHARBROILER. Installation and Operation Instructions GAS CHARBROILER Installation and Operation Instructions 2M-W1649 Rev. A 4/07/11 IL1883a WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury

More information

USER MANUAL Gas Countertop Charbroilers

USER MANUAL Gas Countertop Charbroilers Gas Countertop Charbroilers REVISED 2/209 382799 LAVA BRIQUETTE MODELS: 35CLCPG5NL, 35CLCPG24NL, 35CLCPG36NL, 35CLCPG48NL, 35CLCPG60NL, 35CLCPG72NL Congratulations on your purchase of Cooking Performance

More information

GAS FULL SIZE COMPUTERIZED CONVECTION OVEN GCOF-T

GAS FULL SIZE COMPUTERIZED CONVECTION OVEN GCOF-T GAS FULL SIZE COMPUTERIZED CONVECTION OVEN GCOF-T Installation and Operation Instructions 2M-W1349 Rev. A 10/27/15 GCOF-T SAFETY SYMBOL These symbols are intended to alert the user to the presence of important

More information

OWNER S MANUAL INSTRUCTIONS, INSTALLATION, OPERATION, MAINTENANCE RHPE & RTGE SERIES (ELECTRIC COUNTERTOPS) RETAIN THIS MANUAL FOR FUTURE REFERENCES.

OWNER S MANUAL INSTRUCTIONS, INSTALLATION, OPERATION, MAINTENANCE RHPE & RTGE SERIES (ELECTRIC COUNTERTOPS) RETAIN THIS MANUAL FOR FUTURE REFERENCES. 3245 Corridor Drive, Eastvale, CA 91752 800.769.2414 951.360.1600 951.360.7500 (Fax) OWNER S MANUAL INSTRUCTIONS, INSTALLATION, OPERATION, MAINTENANCE RHPE & RTGE SERIES (ELECTRIC COUNTERTOPS) FOR YOUR

More information

ELECTRIC COMPACT DECK OVEN INSTALLATION - OPERATION - MAINTENANCE

ELECTRIC COMPACT DECK OVEN INSTALLATION - OPERATION - MAINTENANCE 1415 ELECTRIC COMPACT DECK OVEN INSTALLATION - OPERATION - MAINTENANCE BLODGETT OVEN COMPANY www.blodgett.com 44 Lakeside Avenue, Burlington, Vermont 05401 USA Telephone: (802) 658-6600 Fax: (802)864-0183

More information

ELECTRIC DECK OVENS INSTALLATION & OPERATING MANUAL

ELECTRIC DECK OVENS INSTALLATION & OPERATING MANUAL ELECTRIC DECK OVENS INSTALLATION & OPERATING MANUAL MODELS: EDO 2136-1, EDO-42-1, EDO 57-1, EDO 42-3, EDO 57-3 FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE

More information

Mobile Hot Food Merchandiser Series. Series: MHB Operation Manual

Mobile Hot Food Merchandiser Series. Series: MHB Operation Manual Mobile Hot Food Merchandiser Series Series: MHB Operation Manual BKI LIMITED WARRANTY Grandview Drive Simpsonville, SC 0 USA () - Toll Free: (00) - Fax: () - WHAT IS COVERED WHO IS COVERED COVERAGE PERIOD

More information

INSTALLATION, OPERATION & MAINTENANCE MANUAL

INSTALLATION, OPERATION & MAINTENANCE MANUAL INSTALLATION, OPERATION & MAINTENANCE MANUAL MODELS 2 GRD 2 HP 3 GRD 3 HP 2 and 3 STEAM Griddles For additional information on American Griddle products, or to locate an authorized parts and service provider

More information

Installation, Operation, and Maintenance Manual RTE14S & RTE14S-2. For the Taco Bell "Rethermalizer" Model Numbers

Installation, Operation, and Maintenance Manual RTE14S & RTE14S-2. For the Taco Bell Rethermalizer Model Numbers Installation, Operation, and Maintenance Manual For the Taco Bell "Rethermalizer" Model Numbers RTE14S & RTE14S-2 NOTICES There are three different types of notices that you should be familiar with, a

More information

USER MANUAL Gas Step Up Hot Plate

USER MANUAL Gas Step Up Hot Plate USER MANUAL Gas Step Up Hot Plate MODELS: CK HPSU, CK HPSU, CK HPSU 0 / 07 IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment. For Warranty

More information

IRCS2-SBD Conveyor Toasters

IRCS2-SBD Conveyor Toasters MODEL IRCS2-SBD Conveyor Toasters IL2707 Electronic Controls Conveyor Toasters Installation Instructions These symbols are intended to alert the user to the presence of important operating and maintenance

More information

S6161-KW-FSE-010/ LP

S6161-KW-FSE-010/ LP S6161-KW-FSE-010/34931 0910-LP-327-9700 OPERATION AND SERVICE MANUAL FOR SHIPBOARD ELECTRIC CONVECTION OVENS MODEL NUMBERS ECO-6M, ECO-7M, ECO-8M, and ECO- 9M LANG MANUFACTURING COMPANY 6500 MERRILL CREEK

More information

OWNER'S MANUAL. FRY Holding Unit (FHU) MODELS FHU1 FHU2. Duke Manufacturing Company

OWNER'S MANUAL. FRY Holding Unit (FHU) MODELS FHU1 FHU2. Duke Manufacturing Company OWNER'S MANUAL FRY Holding Unit (FHU) Patent(s) Pending MODELS FHU FHU IMPORTANT INFORMATION, READ BEFORE USE. PLEASE SAVE THESE INSTRUCTIONS. This manual is Copyright 04 Duke Manufacturing Company. All

More information

CART & TROUGH ASSEMBLY for BRAISING PAN UNITS

CART & TROUGH ASSEMBLY for BRAISING PAN UNITS OPERATOR MANUAL IMPORTANT INFORMATION, KEEP FOR OPERATOR This manual provides information for: CART & TROUGH ASSEMBLY for BRAISING PAN UNITS Stainless Steel THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.

More information

Operators and Service Manual

Operators and Service Manual Operators and Service Manual Hot Dry Channel Holding Unit For information or technical assistance, call: TOLL FREE (800) 735-DUKE (3853) or (314) 231-1130 Rev 08/22/2008 1 of 14 228987 214 DRY CHANNEL

More information

ELECTRIC COUNTERTOP DECK OVEN INSTALLATION & OPERATING MANUAL

ELECTRIC COUNTERTOP DECK OVEN INSTALLATION & OPERATING MANUAL ELECTRIC COUNTERTOP DECK OVEN INSTALLATION & OPERATING MANUAL MODELS: CT-301 and CT-302 FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY

More information

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions Please read this manual completely prior to installing and operating this equipment. This manual describes how

More information

BROIL-O-DOG MODEL 174CBA, 174SBA 175CBA, 175SBA. Installation and Operation Instructions 175CBA. 2M-Z3755 Rev. L 10/01/2015.

BROIL-O-DOG MODEL 174CBA, 174SBA 175CBA, 175SBA. Installation and Operation Instructions 175CBA. 2M-Z3755 Rev. L 10/01/2015. BROIL-O-DOG MODEL 174CBA, 174SBA 175CBA, 175SBA Installation and Operation Instructions 2M-Z3755 Rev. L 10/01/2015 175CBA (120V Only) SAFETY SYMBOL These symbols are intended to alert the user to the presence

More information

TECHNICAL MANUAL TM... Fryer, Deep-Fat, Electric w/solid State Controls 440 Volt, 60 HZ, 3 Phase NSN:

TECHNICAL MANUAL TM... Fryer, Deep-Fat, Electric w/solid State Controls 440 Volt, 60 HZ, 3 Phase NSN: TM... TECHNICAL MANUAL MODEL USN-50 DESCRIPTION Fryer, Deep-Fat, Electric w/solid State Controls 440 Volt, 60 HZ, 3 Phase NSN: Commercial & Marine Cooking Equipment Gas & Electric Last Updated September

More information

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor AQUATEMP TM HUMIDITY CONVECTION and RETHERM OVENS with MICROPROCESSOR CONTROLS

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor AQUATEMP TM HUMIDITY CONVECTION and RETHERM OVENS with MICROPROCESSOR CONTROLS 9 Heisley Road Mentor, OH 0- Rev. (6/0) Page of INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor AQUATEMP TM HUMIDITY CONVECTION and RETHERM OVENS with MICROPROCESSOR CONTROLS ROFWB-Q COFWUAB-Q

More information

OWNER S MANUAL PREMIER SERIES HIGH PERFORMANCE ELECTRIC CONVECTION OVEN. MODELS: m 3000 m 3092

OWNER S MANUAL PREMIER SERIES HIGH PERFORMANCE ELECTRIC CONVECTION OVEN. MODELS: m 3000 m 3092 OWNER S MANUAL PREMIER SERIES HIGH PERFORMANCE ELECTRIC CONVECTION OVEN MODELS: m 000 m 092 WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury

More information

Electric Griddles OPERATING/INSTALLATION INSTRUCTIONS

Electric Griddles OPERATING/INSTALLATION INSTRUCTIONS PART #335376 Electric Griddles OPERATING/INSTALLATION INSTRUCTIONS CAUTION INSPECT CONTENTS IMMEDIATELY AND FILE CLAIM WITH DELIVERING CARRIER FOR ANY DAMAGE. SAVE YOUR BOX AND ALL PACKING MATERIALS. YOU

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL DRAWER WARMERS CHIP WARMERS MODELS: CHIP WARMERS: 200-1-CW 200-2-CW DRAWER WARMERS: CAFÉ : 200-1R-C 200-2R-C 200-3R-C 200-4R-C CAFE BUILT-IN: 200-1R-BI-C 200-2R-BI-C 200-3R-BI-C 200-3R-BI-C INSTALLATION

More information

Product Identification

Product Identification Operation Manual Split Lid Contact Grill Product Identification Single Top Split Top LIMITED WARRANTY This product is warranted to be free from defects in material and/or workmanship for a period of 1

More information

Installation. Operation. Maintenance LA 36 Deck Oven

Installation. Operation. Maintenance LA 36 Deck Oven Installation Operation Maintenance LA 36 Deck Oven Lang Manufacturing Company 6500 Merrill Creek Parkway Everett, WA 98203 Part Number: 60804-01 Phone: 425-349-2400 Fax: 425-349-2483 03/30/00 TABLE OF

More information

RW1HD RW2HD RW3HD RWN1 RWN2 RWN3

RW1HD RW2HD RW3HD RWN1 RWN2 RWN3 WELLS MANUFACTURING 10 Sunnen Dr., St. Louis, MO 63143 telephone: 314-678-6314 fax: 314-781-2714 www.wellsbloomfield.com 041 OWNERS MANUAL FREE STANDING DRAWER WARMERS with THERMOSTATIC CONTROL Model RW2HD

More information

DESIGN CLASS FUNCTION

DESIGN CLASS FUNCTION PROFESSIONAL QUALITY COOKING EQUIPMENT INSTALLATION MANUAL FOR MEDALLION DUAL FUEL RANGES MODEL NUMBERS: ARR-304DF, ARR-366DF, ARR-364GDDF, ARR-364GRDF, ARR-486GDDF, ARR-486GRDF, ARR-4822GDDF, ARR-484X2GRDF,

More information

OPERATION MANUAL COUNTERTOP ELECTRIC CHAR BROILERS. for. Models: B-40 B-44 B-50. includes: INSTALLATION, USE and CARE

OPERATION MANUAL COUNTERTOP ELECTRIC CHAR BROILERS. for. Models: B-40 B-44 B-50. includes: INSTALLATION, USE and CARE WELLS BLOOMFIELD, LLC 2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439 telephone: 775-689-5703 fax: 775-689-5976 www.wellsbloomfield.com 161 Model B-40 OPERATION MANUAL for COUNTERTOP ELECTRIC CHAR BROILERS

More information

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions Please read this manual completely prior to installing and operating this equipment. This manual describes how to install,

More information

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER Rev. 1 (1/16) Page 1 of 12 INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER REVOLUTION FOODS MODEL CO151027 Rev. 1 (1/16) Page 2 of 12 TABLE OF CONTENTS SUBJECT PAGE INSTALLATION

More information

R-RCM & R-RSB SERIES

R-RCM & R-RSB SERIES R-RCM & R-RSB SERIES CHEESEMELTER & SALAMANDER BROILERS INSTALLATION - OPERATION - MAINTENANCE CHEESEMELTERS R-RCM-24 R-RCM-36 R-RCM-48 R-RCM-60 SALAMANDERS R-RSB-24 R-RSB-36 R-RSB-48 Telephone: (802)

More information

Insta-Therm Series Service, Installation and Operation Manual

Insta-Therm Series Service, Installation and Operation Manual Insta-Therm 16000 Series Service, Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components

More information

OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions

OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions 634 10 Sunnen Drive St. Louis, MO 63143 telephone: 314-678-6336 fax: 314-781-2714 www.bloomfieldworldwide.com OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901 Includes: Installation

More information

INSTRUCTIONS. Installation, operation and care of HD SERIES HOT DELI DISPLAY CASES. MODEL HD5 Full-Service IMPORTANT READ BEFORE USING DISPLAY CASE

INSTRUCTIONS. Installation, operation and care of HD SERIES HOT DELI DISPLAY CASES. MODEL HD5 Full-Service IMPORTANT READ BEFORE USING DISPLAY CASE INSTRUCTIONS Installation, operation and care of HD SERIES HOT DELI DISPLAY CASES MODELS Full-Service Humidified Full-Service Self-Service HD3 HD4 HD5 HD7 HD3 HD4 HD5 HD7 HD3 HD4 HD5 MODEL HD5 Full-Service

More information

Model LRC7 Rethermalizing Oven OPERATION, INSTALLATION, SERVICE and PARTS MANUAL

Model LRC7 Rethermalizing Oven OPERATION, INSTALLATION, SERVICE and PARTS MANUAL Model LRC7 Rethermalizing Oven OPERATION, INSTALLATION, SERVICE and PARTS MANUAL LBC Bakery Equipment, Inc. 6026 31 st Ave NE Tulalip, WA 98271, USA Phone: 888-RACKOVN (888-722-5686) Email: parts@lbcbakery.com

More information

VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016

VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016 VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016 HOODMART 172 REASER COURT ELYRIA, OH 44035 PHONE: (800)-715-1014 FAX: (800)-716-1214 1 THIS PAGE LEFT BLANK INTERNTIONALLY 2 LIMITED

More information

BROIL-O-DOG MODEL 174CBA, 174SBA 175CBA, 175SBA. Installation and Operation Instructions 175CBA. 2M-Z3755 Rev. L 10/01/2015.

BROIL-O-DOG MODEL 174CBA, 174SBA 175CBA, 175SBA. Installation and Operation Instructions 175CBA. 2M-Z3755 Rev. L 10/01/2015. BROIL-O-DOG MODEL 74CBA, 74SBA 75CBA, 75SBA Installation and Operation Instructions 2M-Z3755 Rev. L 0/0/205 75CBA (20V Only) SAFETY SYMBOL These symbols are intended to alert the user to the presence of

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL VW & VSL SERIES DRAWER WARMERS VCW1, VCW2 CHIP WARMERS MODELS: CHIP WARMERS: VCW1 ML-138038 VCW2 ML-138041 DRAWER WARMERS: CAFÉ : VW1S ML-126500 VW2S ML-126502 VW3S ML-126504

More information

Installation Instructions

Installation Instructions 50ES--A, 50EZ--A, 50VG--A, B, 50VL--A, B, 50VR--A, 50VT--A, B 604D-- --A, 607C-- --A, B, 607E-- --A, 704D-- --A, 707C-- --A, B, 707E-- --A PA3G -- -- A, PH3G -- -- A, PA4G, PH4G PAD3, PHD3, PAD4, PHD4,

More information

DRAWER ROLL/ BUN WARMER

DRAWER ROLL/ BUN WARMER DRAWER ROLL/ BUN WARMER MODEL SST-20 SST-30 SST-50 SST-75 Installation and Operation Instructions 2M-Z3235 Rev. G 2/5/200 IL889 SST-75 SAFETY SYMBOL These symbols are intended to alert the user to the

More information

HOT FOOD HUMIDITY CABINET

HOT FOOD HUMIDITY CABINET HOT FOOD HUMIDITY CABINET MODEL HFD-1 Installation and Operation Instructions M-Z0 Rev. J 10//07 HFD-1 1 SAFETY SYMBOL These symbols are intended to alert the user to the presence of important operating

More information

Water Boilers ME10EN, ME15EN. Table of Contents

Water Boilers ME10EN, ME15EN. Table of Contents Water Boilers ME10EN, ME15EN Operator Manual Model ME15EN Model ME10EN Safety Information...2 Rough-In Drawing...3 Installation...4 Priming...5 Cleaning...5 Table of Contents Adjustments...6 Maintenance...7

More information

Installation Instructions Dual Fuel Ranges

Installation Instructions Dual Fuel Ranges Installation Instructions Dual Fuel Ranges E30DF74EPS E36DF76EPS E48DF76EPS 5995447082 2 Safety IMPORTANT SAFETY INSTRUCTIONS Safety Precautions Do not attempt to install or operate your unit until you

More information

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER Rev. 0 (4/14) Page 1 of 11 INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER REVOLUTION FOODS MODEL CO15102 Rev. 0 (4/14) Page 2 of 11 TABLE OF CONTENTS SUBJECT PAGE INSTALLATION

More information

Installation Instructions

Installation Instructions 50ES---A, 50EZ---A, 50VL---A, 50VG---A, 50VR---A, 50VT---A, 604D--- ---A, 607C--- ---A, 607E,--- ---A, 704D--- ---A, 707C--- ---A, 707E--- ---A PA3G --- --- A, PH3G --- --- A SMALL PACKAGED PRODUCTS Electric

More information

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor RADIANT OVENS

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor RADIANT OVENS FL--D 595 Heisley Road Mentor, OH 440-8 Rev. 0 (5/) Page of INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor RADIANT OVENS 000-CH-SS-D 000-CH-AL-D 000-CH-SS-SPLIT-D 000-CH-AL-SPLIT-D 000-CH-SS-SPLIT-D0

More information

DESIGN CLASS FUNCTION

DESIGN CLASS FUNCTION PROFESSIONAL QUALITY COOKING EQUIPMENT INSTALLATION MANUAL FOR PERFORMER SLIDE-IN COOK TOPS MODEL NUMBERS: AROBSCT-424, AROBSCT-242GD, AROBSCT-24X2GR, AROBSCT-430, AROBSCT-636, AROBSCT-436GD, AROBSCT-436GR,

More information

HOT FOOD HUMIDITY CABINET

HOT FOOD HUMIDITY CABINET HOT FOOD HUMIDITY CABINET MODEL HFD- Installation and Operation Instructions 2M-Z02 Rev. M 8//20 HFD- SAFETY SYMBOL These symbols are intended to alert the user to the presence of important operating and

More information

Installation Instructions

Installation Instructions EHNA Electric Heaters 5-20kW For 60 Hz Small Packaged Products MODELS: PAD3, PHD3, PAD4, PHD4, PAD5, PHD5, WPA3, WPH3 Installation Instructions NOTE: Read the entire instruction manual before starting

More information

INSTALLATION, OPERATION & MAINTENANCE AVANTCO SERIES 177AG OWNER S MANUAL

INSTALLATION, OPERATION & MAINTENANCE AVANTCO SERIES 177AG OWNER S MANUAL INSTALLATION, OPERATION & MAINTENANCE AVANTCO SERIES 177AG OWNER S MANUAL Manual Griddles: Radiant Charbroilers: Hot Plates: 177AG24MG 177AG36MG 177AG24RC 177AG36RC 177AGR212 All equipment manufactured

More information

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40 INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40 CROWN FOOD SERVICE EQUIPMENT LTD. 70 OAKDALE ROAD, DOWNSVIEW, (TORONTO), ONTARIO, CANADA, M3N 1V9 TELEPHONE: (416) 746-2358, FAX: (416)

More information

Seaward Products. OWNER S MANUAL Installation Operation - Maintenance. Princess Gourmet Model 345. Built-in Electric Oven ELECTRIC WALL OVEN

Seaward Products. OWNER S MANUAL Installation Operation - Maintenance. Princess Gourmet Model 345. Built-in Electric Oven ELECTRIC WALL OVEN Seaward Products ELECTRIC WALL OVEN OWNER S MANUAL Installation Operation - Maintenance Princess Gourmet Model 345 Built-in Electric Oven IMPORTANT: Read all instructions before operating Oven. Save the

More information

Glass Door Merchandiser Refrigerator and Freezer

Glass Door Merchandiser Refrigerator and Freezer Glass Door Merchandiser Refrigerator and Freezer (Swing and Sliding Door ) Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment.

More information

TRI-STAR INC SOUTH STANDARD AVENUE, SANTA ANA, CA Ph: Fax: MODEL #. OWNER S MANUAL

TRI-STAR INC SOUTH STANDARD AVENUE, SANTA ANA, CA Ph: Fax: MODEL #. OWNER S MANUAL TRI-STAR INC 2205 SOUTH STANDARD AVENUE, SANTA ANA, CA 92707 Ph: 714 424 9380 Fax: 714 424 9385 MODEL #. OWNER S MANUAL INSTALLATION OPERATION MAINTENANCE All equipments manufactured by Tri-star Inc. for

More information

OWNERS MANUAL INSTALLATION, OPERATION, & MAINTENANCE INSTRUCTIONS

OWNERS MANUAL INSTALLATION, OPERATION, & MAINTENANCE INSTRUCTIONS OWNERS MANUAL INSTALLATION, OPERATION, & MAINTENANCE INSTRUCTIONS 1128 Sherborn Street Corona, CA 92879-2089 (951) 281-1830 FAX (951) 281-1879 ELECTRIC RESTAURANT RANGES WARNING: Improper installation,

More information

Instruction Manual for the Globe Electric Countertop Griddles Model PG24E & PG36E

Instruction Manual for the Globe Electric Countertop Griddles Model PG24E & PG36E Serial #: Model PG36E Shown Instruction Manual for the Globe Electric Countertop Griddles Model PG24E & PG36E For Service on Your Griddle: 1. Visit our website at www.globeslicers.com (select the Parts

More information

BROIL-O-DOG MODEL 174CBA, 174SBA 175CBA, 175SBA. Installation and Operation Instructions 2M-Z3755 Rev. J 10/4/06 175CBA.

BROIL-O-DOG MODEL 174CBA, 174SBA 175CBA, 175SBA. Installation and Operation Instructions 2M-Z3755 Rev. J 10/4/06 175CBA. BROIL-O-DOG MODEL 174CBA, 174SBA 175CBA, 175SBA Installation and Operation Instructions 2M-Z3755 Rev. J 10/4/06 175CBA (120V Only) 1 SAFETY SYMBOL These symbols are intended to alert the user to the presence

More information

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call Service Manual Design Basics Hot Food Tables Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF For Service Information, Call 800-544-3057 Please provide the following information: - Model number - Serial

More information

ELECTRIC UNIT HEATER REGULAR DUTY

ELECTRIC UNIT HEATER REGULAR DUTY ELECTRIC UNIT HEATER REGULAR DUTY Installation Form RGM 428 (MI500 Revision 0) APPLIES TO: Model EGE INDEX (by page number) Clearance to Combustibles... 3 Dimensions... 4 Electrical... 4 Fan Motor... 4

More information

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 12kW QUIKTHERM RETHERM OVENS

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 12kW QUIKTHERM RETHERM OVENS Rev. 2 (7/13) Page 1 of 11 INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 12kW QUIKTHERM RETHERM OVENS RO151029 Rev. 2 (7/13) Page 2 of 11 TABLE OF CONTENTS SUBJECT PAGE INSTALLATION INSTRUCTIONS...

More information

MANUFACTURING NUMBERS: CORN CAROUSEL. Model CC-19 Series P/N /99. Owner s Manual

MANUFACTURING NUMBERS: CORN CAROUSEL. Model CC-19 Series P/N /99. Owner s Manual MANUFACTURING NUMBERS: 9500410 9500412 C US Model CC-19 Series 9500400 P/N 1010730 10/99 Owner s Manual A.J. Antunes & Co. Owner Information...1 General...1 Warranty Information...1 Service/Technical Assistance...2

More information

E-Chef Hot Food Table Installation and Operation Manual

E-Chef Hot Food Table Installation and Operation Manual E-Chef Hot Food Table Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately.

More information

Owner s Information Manual

Owner s Information Manual 48ES---A and 48VL---A Comfort and Performance 13 and 14 SEER Single Packaged Air Conditioner and Gas Furnace System With Puron (R---410A) Refrigerant Single and Three Phase 2---5 Nominal Tons (Sizes 24---60)

More information

BUILT-IN OVEN MODEL: EBO-D7080D(SS) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference.

BUILT-IN OVEN MODEL: EBO-D7080D(SS) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference. BUILT-IN OVEN MODEL: EBO-D7080D(SS) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference. Record model number and serial number of the set. See the

More information

Solid Door Top Mount Reach-In Freezer

Solid Door Top Mount Reach-In Freezer Solid Door Top Mount Reach-In Freezer Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment. Notify carrier of damage! Inspect

More information

CINCINNATI, OH USA

CINCINNATI, OH USA INSTRUCTION MANUAL Part No. 89731 Revised October 1997 CINCINNATI, OH 45241-4807 USA GAS SAFETY PRECAUTIONS Instructions on what to do when a user smells gas can be obtained from the local gas supplier.

More information

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 8kW QUIKTHERM RETHERM OVENS

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 8kW QUIKTHERM RETHERM OVENS Rev. 1 (6/13) Page 1 of 11 INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 8kW QUIKTHERM RETHERM OVENS REVOLUTION FOODS MODEL RO151033 Rev. 1 (6/13) Page 2 of 11 TABLE OF CONTENTS SUBJECT PAGE

More information

Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator

Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment. Notify

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL V SERIES FOOD HOLDING & TRANSPORTATION CABINETS MODELS: VB90 VB96 VB150 VBP5I VBP7I VBP13I VBP15I VBP33 VBP77I VBS15 VHA9 VHA18 VHDP5 VHFA9 VHFA18 VHP3 VHP7 VHP8 VHP15 VHP20

More information

COUNTER TOP REFRIGERATION MODEL SERIES HUBM-2RB/HUBM-2FB/HUBM-3.5RB/HUBM-3.5FB HUBM-2R/HUBM-2F/HUBM-3.5R/HUBM-3.5F

COUNTER TOP REFRIGERATION MODEL SERIES HUBM-2RB/HUBM-2FB/HUBM-3.5RB/HUBM-3.5FB HUBM-2R/HUBM-2F/HUBM-3.5R/HUBM-3.5F HUBM-2R HUBM-2F HUBM-3.5R HUBM-3.5F HUBM-2RB HUBM-2FB HUBM-3.5RB HUBM-3.5FB Please read this manual completely before attempting to install or operate this equipment. Notify carrier of damage! Inspect

More information

Technical Manual and Replacement Parts List. Mobile Freezer

Technical Manual and Replacement Parts List. Mobile Freezer Technical Manual and Replacement Parts List Mobile Freezer MODEL SKFS2 1600 Xenium Lane North, Minneapolis, MN 55441-3787 Phone (763) 923-2441 1 Specifications Subject to Change Without Notice. TECHNICAL

More information

INSTALLATION MANUAL. Double Electric Wall Oven

INSTALLATION MANUAL. Double Electric Wall Oven INSTALLATION MANUAL Double Electric Wall Oven 799258 BLUESTAR INSTALLATION INSTRUCTIONS FOR THE RESIDENTIAL ALL ELECTRIC WALL OVEN FOR THE HOME MODELS DEWO THIS APPLIANCE WAS DESIGNED FOR EASE OF INSTALLATION

More information