Technical Data Sheet for Sunergy SOLAR ENERGY PROCESSOR Model SEP3G10

Size: px
Start display at page:

Download "Technical Data Sheet for Sunergy SOLAR ENERGY PROCESSOR Model SEP3G10"

Transcription

1 Technical Data Sheet for Sunergy SOLAR ENERGY PROCESSOR Model SEP3G1 Minus7 equipment and Systems are to be designed, installed and maintained by Minus7 personnel only. Contents General Description! 2 Performance characteristics! 3 Heat pump performance! 3 Sound characteristics 3 Electrical Characteristics 3 Operating Range 4 Protection devices fitted! 4 Instructions for installation! 5 Instructions for maintenance 5 Schematic - Endothermic System! 6 Pump Data sheet! 7 Document Revision data! 9 1 of 9 SEP Technical Data sheet rev 2.4.pages

2 General Description The Minus7 Solar Energy Processor is the plant for generating, harvesting and distributing thermal energy. The plant consists of a Heat Pump Module, endothermic heat collection module, domestic hot water module, heat distribution interface with back-up heater and master control system. Minus7 Solar Energy Processor Model number SEP3G1 Power supply 23 vac - 5 hz - single phase Incorporates Brine to water heat pump model number HPM1 (see HPM data sheet for details) Brine circuit pump - Wilo Stratos Para.85 watts at 23 vac 5 hz single phase Water circuit pump - Wilo Stratos Para.85 watts at 23 vac 5 hz single phase Collector circuit pump - Wilo Stratos Para.85 watts at 23 vac 5 hz single phase Heat exchangers - AlfaLaval AlfaNova 14 stainless steel fused plate heat exchangers. These are used for heat transfer into the following circuits: 1:Collector to Brine circuit. 2:Collector to water circuit. 3: water to space heating circuit and 4: water to domestic hot water pre-heat circuit. Brine solution THERMOX DTX at 3% conc by volume. Frost protection to -18 C. Although based on Ethylene Glycol, THERMOX DTX has been tested and classified as Non-Toxic by an EPA certified laboratory. DeTox prevents Ethylene Glycol from being metabolised (during digestion) into toxic byproducts, which cause kidney failure, blindness and death. Tests carried out on THERMOX DTX confirmed the toxicity was so low that it was impossible to determine an LD5 value.thermox DTX contains synergistic corrosion inhibitors to protect metals commonly found in such systems. It has been tested in accordance with BS5117 and found to meet BS658 corrosion standards for mild & stainless steel, aluminium, copper, brass and cast iron. Zinc or galvanised components are not recommended for use with closed loop cooling or heating systems. THERMOX DTX also contains scale and biological inhibitors to help prevent fouling thus promoting long operational life and high thermal efficiency. THERMOX DTX mixtures are readily biodegradable (9% over ten days) and will not remain in the environment or bio-accumulate. THERMOX DTX is miscible with water in all proportions. SEP Dimensions 1mm wide x 6mm deep x 85mm tall Weight approx 225kg dry Approx water content in all circuits Brine circuit approximately 5.2 litres Water circuit approximately 3.8 litres DHW circuit approximately 2 litres Space heating circuit approximately 1 litres The domestic hot water circuit consists of a flow meter to to detect and monitor flow in the circuit, a plate heat exchanger to transfer heat from the hot store into the heating circuit mains water supply, a pressure regulating valve set to deliver water at 2 bar together with a flow regulating valve, a UV purifier and a pair of in line immersion heaters. The water is pre-heated by means of the plate heat exchanger taking heat from the hot store, then treated using a Silverline UV-DS15 UV purifier to eliminate legionella prior to being delivered to the regulated in-line immersion heaters. The output temperature is regulated to 44 C by the DHW controller. The flow meter is fitted in the circuit to act as a demand switch and to monitor the flow rate. 2 of 9 SEP Technical Data sheet rev 2.4.pages

3 Space heating circuit consists of a flow meter to to detect and monitor flow in the circuit, a plate heat exchanger to transfer heat from the hot store into the heating circuit and a back-up in line immersion heater. Solar collector circuit consists of a flow meter, circulating pump, two plate heat exchangers, and a pressure relief valve. The brine circuit consists of a flow meter, a circulating pump, a three port motorised valve a plate heat exchanger connected to the solar collector circuit and the evaporator heat exchanger. Performance characteristics Heat pump performance Test results as per the requirements of BS EN14511: 27 Air Conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling Parts 1 to 4 These ratings apply to a new unit with clean heat exchangers when fitted into Sunergy Solar Energy Processor (SEP) and allows for pump overheads. Test condition COP Heating capacity Total Power input Standard rating test / 3 C kw kw Test 2 / 4 C kw 3.17 kw Test 3 5 / 3 C kw kw Test 4 1 / 3 C kw kw Sound characteristics The A-weighted sound power level (LwA) according to BS EN ISO 3744: dB(A) when in enclosure. Compressor sound power level without sound enclosure or jacket - 73dB(A) Compressor sound 1m - 62dB(A) minus 5dB(A) for fitted sound jacket Electrical Characteristics Maximum starting current heat pump mode Normal run current heat pump mode Maximum Operating Current heat pump mode Locked rotor current heat pump compressor Start Winding Resistance heat pump compressor 26 ampere at 23vac 5hz 14.3 ampere at 23vac 5hz 25 ampere at 23vac 5 hz 18 ampere 1.9 ohms Winding Resistance heat pump compressor.6 ohms Control system 5 watts Normal run current solar thermal 1.26 ampere Maximum run current DHW 33 ampere 3 of 9 SEP Technical Data sheet rev 2.4.pages

4 Maximum run current Space heating backup 16 ampere UV steriliser (optional) 15 watt Danfos 3 port valves 6 watt Wilo Stratos Para pumps (see data sheet) 8 watt (Condenser pump, Evaporator pump and Collector pump) Note an additional collector Booster pump rated at 4 watts Wilo Yanos Pico is added when the second and third 2 sqm panels are added. Operating Range Temperature range of source fluid Temperature range of heated fluid (Load) -6 C to +2 C +3 to +4 C Flow rate of primary circuit (source) Flow rate of secondary circuit (Load) Flow rate of Collector circuit (solar) Flow rate DHW circuit (regulated) Delivery pressure DHW (regulated).656 l/s to.277 l/s.484 l/s to.277 l/s.484 l/s to.277 l/s 6 litres / minute 2 bar Protection devices fitted Gas circuit Electrical Heat pump compressor low pressure cutout. High pressure cutout. High temperature cutout 32a type D circuit breaker Thermal cutout. (Auto re-set) The Heat-pump circuit is fitted with a low pressure cut-out (29) switch. In the event of this operating the system shuts down the compressor and displays a solid red light on the control panel. If the LP condition clears the system will clear the fault state at the next timed run period or it can be cleared by the operator by toggling the reset button on the control panel. The Heat-pump circuit is fitted with a high pressure cut-out (28). In the event of the HP cut-out operating the system shuts the compressor down and the system displays a solid red light on the control panel. This HP cutout is mechanically latched. It can only be cleared by the operator reseting the electro-mechanical switch. When cleared the control system must be cleared by toggling the reset button on the panel. The system after detecting this failure state will continue to allow the collection of thermal energy to be delivered to the hot and cold stores HP cutout reset button Heat pump module Control system, status display, system fault reset button and circuit fuses 4 of 9 SEP Technical Data sheet rev 2.4.pages

5 Protection for pumps is provided by the monitoring the flow in the individual circuits and turning the pumps off when the flow falls below the set point. Hot water generator safety cutout is thermal cutout on each immersion DHW back-up heater safety cutout is thermal cutout on the immersion. Instructions for installation See Sunergy installation manual for full details. Electrical connections are to be made on site to the two independent 32 ampere power supplies. These are to be protected with type D circuit breakers. Cable size to be 6 mm sq minimum for the SEP and 1mm sq for the DHW generator circuit. Flow and return circuit to the collector Flow and return to the hot store Flow and return to the cold store Mains water feed Connection to the DHW distribution circuit for the building Flow and return to the heat distribution circuit Sensor connections to the temperature sensors on the collector, the hot store, the cold store and ambient air temperature. Instructions for maintenance There are no user serviceable items in the plant Annual service by qualified technician to comprise Heat pump module: Check satisfactory operation of compressor For a unit containing between 3Kg and 29Kg of HFC, maintenance and leak testing are required a minimum of every 12 months. SEP: Check satisfactory operation of pump circuits Check satisfactory calibration of temperature sensors Check satisfactory fluid levels Check satisfactory operation of control system Check satisfactory operation of all immersions Check satisfactory operation of DHW generator system 5 of 9 SEP Technical Data sheet rev 2.4.pages

6 Schematic - Endothermic System Incorporating heat pump module HPM1 6 of 9 SEP Technical Data sheet rev 2.4.pages

7 Pump Data sheet /min - 1 V /min - 9 V /min - 8 V /min - 7 V /min - 6 V /min - 5 V /min - 4 V 14 1 /min - 3 V 1 v ,5 1 1,5 2 2,5 H/m P1/W n= const H/m ,4,8 1,2 1,6 2, V 9 V 8 V 7 V 6 V 3 V 5 V 4 V Wilo-Stratos 25/1-6 Wilo-Stratos 3/1-6 1~23 V - Rp 1 / Rp 1¼ Rp 1 m/s Rp 1¼ p/kpa Q/l/s Q/Igpm p/kpa Wilo-Stratos 25/1-6 Wilo-Stratos 3/ ~23 V - Rp 1 / Rp 1¼ P1/W Δp-c 8 4 P1/W Δp-v ,4,8 1,2 1,6 2, max. 6m 5m 6m 5m 4m 4m 3m min. min. max. max m 2m min. 2m 1m max. Q/l/s Q/Igpm of 9 SEP Technical Data sheet rev 2.4.pages

8 8 of 9 SEP Technical Data sheet rev 2.4.pages

9 Document Revision data Date Revision Signature Monday, 4 July AH Monday, 8 August AH Wednesday, 28 March AH Wednesday, 13 June AH Tuesday, 28 August AH Wed 3 rd April AH Tues 23 rd April AH 9 of 9 SEP Technical Data sheet rev 2.4.pages

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient PRODUCT SELECTION DATA Easy and fast installation Compact, reliable and efficient Class A variable speed circulator available Air-Cooled Liquid Chillers 0RB 008-015 CARRIER participates in the ECP programme

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control. product selection data Compact comfort module DHW management possibility Multi zone option control Easy installation Comfort module with two-zone kit Single-zone comfort module Comfort Module Range for

More information

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

Nominal thermal power kw

Nominal thermal power kw Nominal thermal power 11 118 kw High efficiency air/water and water/water heat pumps with CO 2 refrigerant R744 index 1 Introduction p. 5 2 AIR-WATER 2.1 Technical features p. 15 2.2 Technical specifications

More information

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil Ducted Three Phase Packaged Air Conditioner Technical Data, 0, 180 Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.0 kw 18.5 kw JUNE 5 , 0, 180 DUCTED PACKAGED ROOF TOP AIR CONDITIONERS

More information

Solar heating systems

Solar heating systems 03 energy efficiency Compact, "ALL-IN-ONE" solar system Solar panel for swimming pools Hydraulic components Drain-Unit: dual hydraulic unit with drain back system Drain-Unit: hydraulic unit with drain-back

More information

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features Comfort Module Range for Monobloc Heat Pumps Quality Management Systems Comfort module with two-zone kit Single-zone comfort module 8HMA Nominal heating capacity 4- kw Nominal cooling capacity 4- kw The

More information

LZA High efficiency air to water heat pumps with HP compressor

LZA High efficiency air to water heat pumps with HP compressor High efficiency air to water heat pumps with HP compressor -10 C +43 C +60 C HP C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5

More information

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet: PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL Operation and Maintenance THERMAL INTEGRATION LTD. Tel: 0845 2411441 Internet: www.heatweb.com Introduction The District Pandora Heat Bank provides hot

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating

More information

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS TC SERIES OPTIONS TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15,, 5 AIR COOLED PACKAGED WATER CHILLERS CONTENTS EQUIPMENT AND COMPONENT DETAILS PERFORMANCE AND TECHNICAL DATA SCHEMATIC FLOW & SYSTEM

More information

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or

More information

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water. Temperature Control Units Water & Oil 30-500 F Portable Chillers Air & Water-Cooled 20-70 F Central Chillers Air & Water-Cooled Packages & Modules 20-70 F Pump Tank Stations Chilled or Tower Water 200-3600

More information

AQUASNAP JUNIOR 30RHV

AQUASNAP JUNIOR 30RHV High-Efficiency Air-To-Water Heat Pumps Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. AQUASNAP JUNIOR 3RHV 6-11

More information

Trade Product List 2013 BIOMASS ACCESSORIES

Trade Product List 2013 BIOMASS ACCESSORIES Trade Product List 2013 BIOMASS ACCESSORIES BIOMASS SYSTEM COMPONENTS Constant Temperature Control Accessories CONSTANT TEMPERATURE CONTROL PRODUCTS Order Code Description of Package and Contents Pictures

More information

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2 UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2 Version: 2018_07_19_v2.2 Abstract This is a quick reference guide for selecting the UniQ range of heat batteries for the required application. For designing a

More information

TOSHIBA AIR CONDITIONING

TOSHIBA AIR CONDITIONING Introduction The following specification describes the Toshiba Estia Air to Water Heat Pump system(s) to be installed at the site below: (ADD SITE NAME) The system(s) shall consist of the following components.

More information

30RH B Nominal cooling capacity kw Nominal heating capacity kw

30RH B Nominal cooling capacity kw Nominal heating capacity kw Air-to-Water Heat Pumps with Integrated Hydronic Module AQUASNAP Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products.

More information

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors -15 +63 E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

CHILLER. Operator s & Installation Manual

CHILLER. Operator s & Installation Manual CHILLER MODELS: CH1001-A Operator s & Installation Manual Release Date: August 9, 2002 Publication Number: 620914301 Revision Date: May 6, 2010 Revision: E Visit the IMI Cornelius web site at www.cornelius.com

More information

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual u Air-to-Water Reverse Cycle Heat Pumps AQH 40 to 130 40 to 131 kw 45 to 141 kw Engineering Data Manual EDM AQH-W.3GB Date : November 2007 Supersedes : TM AQH-W.2GB/03.04 Specifications The Aqu@Logic air-to-water

More information

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors High Efficiency ir to Water Split System Heat Pumps With E.V.I. ompressors -20 +43 +65 HP E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor

More information

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:

More information

Technical Data Ducted Three Phase Split System Air Conditioner

Technical Data Ducted Three Phase Split System Air Conditioner ENERGY EFFICIENT ISD / OSA 2 Technical Data Ducted Three Phase Split System Air Conditioner EXTRA LONG LIFE EPOXY COATED OUTDOOR COIL Nominal Cooling Capacity 26.5 kw (Total) JUNE 4 ISD / OSA 2 DUCTED

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Installation, Operation and Maintenance Manual Packaged Chiller Models CC 6601, 6501, 6401, 6301, 6201, 6101 For Service, please contact Pfannenberg Service Company: U.S.A. Pfannenberg Inc. 68 Ward Road.

More information

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions EN 0 / 0 / 00 / 800 Installation, Operating and Servicing Instructions excellence in hot water EN Y000.D EN INDEX Warnings Who should read these instructions Symbols Recommendations Applicable standards

More information

30GN FLOTRONIC II AIR-COOLED CHILLERS

30GN FLOTRONIC II AIR-COOLED CHILLERS 30GN-19SB 30GN040-110 FLOTRONIC II AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GN-19SB Supersedes 30GN-6SB, 30GN-7SB, 30GN-8SB, Printed

More information

WZH Ground source heat pumps

WZH Ground source heat pumps Ground source heat pumps infolinia: +48 691 262 691 +60 C C.O.P. 5,1 HP heat pumps are particularly suitable for applications that utilise well water or ground source probes. These units have been designed

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 +43 +65 E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION 100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest

More information

OPTA-PERIPH 8 Av. de Bretteville Neuilly - France 33(0) Fax : 33(0) Document: IM By PB Date: 18/11/2005

OPTA-PERIPH 8 Av. de Bretteville Neuilly - France 33(0) Fax : 33(0) Document: IM By PB Date: 18/11/2005 OPTA-PERIPH 8 Av. de Bretteville 92 200 Neuilly - France 33(0)6 85 43 82 78 - Fax : 33(0)6 07 18 28 07 User: AIR CONDITIONER ATEX CE II 3G Supplier : OPTA-PERIF Ref : Q/N 0510278 Rev.: 0 Document: IM 050312

More information

30GK. Air-Cooled Liquid Chillers. Nominal cooling capacity kw

30GK. Air-Cooled Liquid Chillers. Nominal cooling capacity kw Air-Cooled Liquid Chillers Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. 30GK Nominal cooling capacity 238-725

More information

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45 Plug & Heat heat pump Quick and easy to install For new homes or boiler backup operation 50 HFC R410A CERTIFIED BY CERTITA Heating capacity: 5.5 to 22 kw option CERTIFIED BY CERTITA 30/35-40/45 USE The

More information

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3 INSTALLATION MANUAL Domestic hot water tank for air to water heat pump system EKHWE50AV EKHWET50AV EKHWE00AV EKHWE00AV EKHWE00AZ EKHWE00AZ 4 5 6 7 x x x 4x x x x EKHWE50~00 EKHWET50 50 50 0 0 00 50 700

More information

High temperature air-to-water heat pumps

High temperature air-to-water heat pumps Designed to replace conventional boilers and produce domestic hot water 4 High temperature hot water (+65 C) 4 Winter operation (-20 C) 4 High energy efficiency (CP) 4 Compact and quiet 4 Scroll compressors

More information

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions ENGLISH 0 / 0 / 0 / 0 / 00 Installation, Operating and Servicing Instructions FRANCAIS NEDERLANDS ESPAÑOL Y000.A EN ESPAÑOL NEDERLANDS FRANCAIS ENGLISH INDEX WARNING Who should read these instructions

More information

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts GTIP60 ISO GT Series, Inch Pounds 60 Hz GT010070 (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts Rev: 903 Rev 1 Revisions: 31103 Changed HZ dwg to field convertible 5902 changed Unit

More information

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES 60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,

More information

INDIRECT SYSTEM FOR FROST LOCATIONS

INDIRECT SYSTEM FOR FROST LOCATIONS SOLAR WATER HEATING INDIRECT SYSTEM FOR FROST LOCATIONS EFFICIENT USE OF NATURAL SOLAR ENERGY FROM THE DOMESTIC SOLAR WATER HEATERS WITH SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES Solar Water Heaters

More information

Comfort. Description. Applications

Comfort. Description. Applications Blower Heater 3-35 kw 10,00-119,40 Btuh 40 to 90 Volts, 50/0 Hz 31 Stainless Steel Case Shown 3 Phase ATEX, GOST, CE IIG Exd IIB T3 Description Type is designed to heat areas classified as hazardous locations

More information

30RBV/30RQV Inverter Air-Cooled Liquid chillers & Reversible Air to Water Heat Pumps PRODUCT SELECTION DATA INSTALLATION, OPERATION AND

30RBV/30RQV Inverter Air-Cooled Liquid chillers & Reversible Air to Water Heat Pumps PRODUCT SELECTION DATA INSTALLATION, OPERATION AND PRODUCT SELECTION DATA INSTALLATION, OPERATION AND Easy and fast installation MAINTENANCE INSTRUCTIONS Hydronic module available Inverter technology compressor and fans Superior reliability Inverter Air-Cooled

More information

SYSTEM DESIGN REQUIREMENTS

SYSTEM DESIGN REQUIREMENTS P a g e 1 SYSTEM DESIGN REQUIREMENTS WFC-S SERIES WATER-FIRED SINGLE-EFFECT ABSORPTION CHILLERS / CHILLER-HEATERS Yazaki WFC-S Series water-fired chillers and chiller-heaters are available with nominal

More information

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd Abstract This paper presents the design approach adopted for the expansion of a large existing

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES LS ir cooled water chillers with axial fans + LS The LS water chiller range has been designed for small and medium residential and commercial applications. They are suitable for generating chilled water

More information

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata EKS/HE Refrigerant R410A GWP=2.088 Scroll Compressor Shell & Tube exchanger Axial fan Brazed plate heat exchanger MultiScroll Air-cooled liquid chillers High efficiency Solution B - Base I - Integrata

More information

Technical data. Danfoss DHP-L

Technical data. Danfoss DHP-L Technical data Danfoss DHP-L Heat pump with the same features as Danfoss DHP-H, but with separate hot water tank. Can reduce heating costs by more than 50 percent. Main parts... 2 Bipack contents... 3

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

1.1 Controller General Information

1.1 Controller General Information 1.1 Controller General Information The Aestiva S1000 controller is differential controller specifically designed for forced circulation solar system. It incorporates a microprocessor driven PCB board and

More information

30XAS A Air-Cooled Liquid Chillers. Nominal cooling capacity kw 50 Hz. Features and advantages. Very economical operation

30XAS A Air-Cooled Liquid Chillers. Nominal cooling capacity kw 50 Hz. Features and advantages. Very economical operation Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Unit with option 279 (compressor enclosure) 30XAS A 242-482 Nominal cooling capacity 232-486 50 Hz The 30XAS Aquaforce liquid

More information

Date: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days

Date: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days Proposal Trane A Division of American Standard Inc. Prepared For: John Weston Desmet Ballestra Job Name: LAUER1 Biodiesel Chiller Pennsylvania Date: August 21, 2006 Proposal Number: G1-95502-1 Engineer:

More information

Technical Data. Danfoss DHP-C. Provides heating, cooling and hot water TWS technology provides hot water quickly with low operating

Technical Data. Danfoss DHP-C. Provides heating, cooling and hot water TWS technology provides hot water quickly with low operating Technical Data Danfoss DHP-C Provides heating, cooling and hot water TWS technology provides hot water quickly with low operating costs A built in 180 litre water tank Main parts... 2 Bipack contents...

More information

COMMERCIAL SOLAR SOLUTIONS

COMMERCIAL SOLAR SOLUTIONS Worldwide experience Biggest range of options Total package solutions 52 Commercial Solar NPT200 collectors provide hot water to Urbanest Student Accommodation Cleveland Street, Redfern NSW COMMERCIAL

More information

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps. Air/water cooled chillers and heat pumps 41 303 kw General BETA ECHOS is a range of chillers and ductable air-water heat pumps. Configurations HP: Reversible heat pump LE: For connection to remote evaporator

More information

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY Easy and fast installation Hydronic module available Compact, reliable and efficient Nominal cooling capacity : 8-40 kw Nominal heating capacity : 17-40 kw 50 410A Cooling or heating USE The air-to-water

More information

RAYPAK HOT WATER & HEATING

RAYPAK HOT WATER & HEATING All copper & bronze construction On/Off & modulating models High temperature applications RAYPAK HOT WATER & HEATING Raypak is a compact, efficient heating design which is the ideal way to heat large quantities

More information

30GX - 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

30GX - 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER 30G - 50 Hz Nominal cooling capacity 384-03 kw The 30G units are air-cooled chillers, designed from the ground up to meet the needs of today and

More information

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water Designed to replace a conventional boiler and produce domestic hot water Heating capacity : 16 to 25 Heating Hydraulic module ENVIRONMENTALLY HFC R4A PROTECTION DE FRIENDLY L'ENVIRONNEMENT USE CIAT is

More information

1/8. Field settings table. Applicable indoor units. *GSQH10S18AA9W ThermaliaC12* Notes - *GSQH10S18AA9W / ThermaliaC12* 4P C

1/8. Field settings table. Applicable indoor units. *GSQH10S18AA9W ThermaliaC12* Notes - *GSQH10S18AA9W / ThermaliaC12* 4P C 1/8 Applicable indoor units *GSQH1S18AA9W ThermaliaC12* Notes - *GSQH1S18AA9W / ThermaliaC12* 4P359382-1C - 214.3 2/8 3/8 User settings Preset values Room temperature 7.4.1.1 Comfort (heating) R/W [3-7]~[3-6],

More information

Providing sustainable energy solutions worldwide. Installation and Maintenance Manual CTC EcoHeat V 3N~ / 230V 1N~

Providing sustainable energy solutions worldwide. Installation and Maintenance Manual CTC EcoHeat V 3N~ / 230V 1N~ 162 105 30-2 2013-09-23 Providing sustainable energy solutions worldwide Installation and Maintenance Manual CTC EcoHeat 400 400V 3N~ / 230V 1N~ Removing the cooling module 1. Disconnect the cooling module

More information

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation. Air-Cooled Liquid Chillers with Integrated Hydronic Module www.eurovent-certification.com www.certiflash.com Model shown is with low-noise option 30RB 162-802 Nominal cooling capacity 162-774 The Aquasnap

More information

30HXC - 50 HZ. Water-Cooled Screw Compressor Liquid Chillers. Nominal cooling capacity kw

30HXC - 50 HZ. Water-Cooled Screw Compressor Liquid Chillers. Nominal cooling capacity kw Water-Cooled Screw Compressor Liquid Chillers Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. 0HC - 50 HZ Nominal

More information

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module PRODUCT SELECTION DATA. Compact design

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module PRODUCT SELECTION DATA. Compact design PRODUCT SELECTION DATA Compact design Alluminium micro-channel heat exchanger technology Fully equipped hydronic module Partial heat reclaim Total heat reclaim Direct expansion free-cooling Air-Cooled

More information

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017 Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air

More information

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump PRODUCT SELECTION DATA Monobloc inverter Compact, reliable and efficient More than a Heat Pump Reversible Air to Water Heat Pump 0AW CARRIER participates in the ECP programme for LCP/HP Check ongoing validity

More information

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09 I N S P I R E D E F F I C I E N C Y Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION Issue 11/09 Technical data Description Extreme 200 Extreme 300 Extreme 500 Weight (empty) kg 63 77

More information

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER

More information

Water-Cooled Dual Compressor Screw Chiller

Water-Cooled Dual Compressor Screw Chiller Installation Manual IM 692-1 Group: Chiller Part Number: 629955 Effective: May 1997 Supersedes: IM663-1 IM683 IM692 Water-Cooled Dual Compressor Screw Chiller Installation Manual PFS 155C through PFS 210C,

More information

30GT FLOTRONIC AIR-COOLED CHILLERS

30GT FLOTRONIC AIR-COOLED CHILLERS 30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed

More information

HIGH-POWER HEAT PUMPS. Up to 300 kw

HIGH-POWER HEAT PUMPS. Up to 300 kw HIGH-POWER HEAT PUMPS Up to 300 kw 1 2 NEW GENERATION OF HEAT PUMPS GORENJE 4 COMPLETE RANGE OF NEW GENERATION HIGH-POWER HEAT PUMPS 8 MODERN CONTROL UNIT HEAT PUMPS AIR-WATER 10 Heat pumps AEROGOR COMPACT

More information

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED Just feel well Renewable Energy MADE IN EUROPE A ++ + PRODUCTS High efficiency: ηs %. High flexibily due to DC Inverter compressor: operation optimised

More information

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

HEAT INTERFACE UNITS (Sanitary Hot Water Only) HEAT INTERFACE UNITS (Sanitary Hot Water Only) T-FAST i20 (Sanitary Hot Water Only) 20 The T-Fast i20 is an instantaneous domestic hot water production module that produces a flow rate of 20L per/min at

More information

YCAL-SB Millennium AIR COOLED LIQUID CHILLER R407C REFRIGERANT. COOLING CAPACITIES 141 kw to 360 kw

YCAL-SB Millennium AIR COOLED LIQUID CHILLER R407C REFRIGERANT. COOLING CAPACITIES 141 kw to 360 kw YCAL-SB Millennium AIR COOLED LIQUID CHILLER R407C REFRIGERANT COOLING CAPACITIES 141 kw to 360 kw YORK YCAL-SB Millennium air cooled scroll liquid chillers provide chilled liquid for all air conditioning

More information

Technical description. Atec.

Technical description. Atec. www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.

More information

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS R Products That Perform...By People Who Care FORM NO: MS0455A WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS R134a HXWC SERIES 205 to 560 Tons 60Hz INTRODUCTION Dunham-Bush's HXWC water cooled

More information

30RB/RQ Air-Cooled Liquid Chillers/Air-to-Water Heat Pumps. product selection data

30RB/RQ Air-Cooled Liquid Chillers/Air-to-Water Heat Pumps. product selection data product selection data Easy and fast installation Hydronic module available Economical operation Superior reliability Air-Cooled Liquid Chillers/Air-to-Water Heat Pumps 30RB/RQ 017-040 CARRIER participates

More information

Installation, operating and servicing instructions

Installation, operating and servicing instructions English 57-115 - 144-1 - 259 Installation, operating and servicing instructions ITALIA EN 1 ITALIA English INDEX WARnINGS 3 Who should read these instructions 3 Symbols 3 Recommendations 3 Importants notes

More information

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the

More information

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWS150B3V3 EKHWS200B3V3 EKHWS300B3V3 EKHWS200B3Z2 EKHWS300B3Z2

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWS150B3V3 EKHWS200B3V3 EKHWS300B3V3 EKHWS200B3Z2 EKHWS300B3Z2 INSTALLATION MANUAL Domestic hot water tank for air to water heat pump system EKHWS50BV EKHWS00BV EKHWS00BV EKHWS00BZ EKHWS00BZ 4 5 6 x x x 4x x + x 00 7 05 0 45 5 400 5 6 00 /4" FBSP 6 H 0 H4 H 0 H 0

More information

Vertical self-contained air conditioner

Vertical self-contained air conditioner Compact and sleek Broad range of functions and performance Energy efficient (EC motor) and self-regulating control Easy to install ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling

More information

WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES

WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES Ground source heat pumps +60 C C.O.P. 5,1 heat pumps are particularly suitable for applications that utilise ground source probes.these units have been designed for use with radiant floor heating systems

More information

Precision Storage Vessels ELECTRIC WATER HEATERS

Precision Storage Vessels ELECTRIC WATER HEATERS Precision Storage Vessels ELECTRIC WATER HEATERS High Capacity Electric Water Heaters Electric calorifiers are one of the easiest method of generating hot water for both domestic and industrial application.

More information

C1N & C2N SERIES Fluid heating for light industrial applications

C1N & C2N SERIES Fluid heating for light industrial applications Keltech Electric Tankless Water Heaters C1N & CN SERIES Fluid heating for light industrial applications Contents Keltech Electric Tankless Water Heaters C1N & CN Series Overview Standard Features 6 Optional

More information

INSTALLATION MANUAL. Domestic hot water tank with option kit for air to water heat pump system EKHWSU150B3V3 EKHWSU200B3V3 EKHWSU300B3V3 EKUHWB

INSTALLATION MANUAL. Domestic hot water tank with option kit for air to water heat pump system EKHWSU150B3V3 EKHWSU200B3V3 EKHWSU300B3V3 EKUHWB INSTALLATION MANUAL Domestic hot water tank with option kit for air to EKHWSU50BV EKHWSU00BV EKHWSU00BV EKUHWB EKUHWWB EKHWSU50BV EKHWSU00BV EKHWSU00BV EKUHWB EKUHWWB CONTENTS Page INTRODUCTION Introduction...

More information

Model 17A00 Expansion Enclosure

Model 17A00 Expansion Enclosure HOME AUTOMATION, INC. Model 17A00 Expansion Enclosure Installation Manual Document Number 17I00-1 Rev A March, 2002 Home Automation, Inc. Model 17A00 Expansion Enclosure Installation Manual Document Number

More information

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

HYDROCIAT LW R407C. Water cooled chillers USE RANGE Screw compressors CIAT dry direct expansion shell and tubes evaporator HPS equipment (High Power System) cooling or heating Heat recovery ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT

More information

TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE:

TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE: TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE: 560955 CE Directive 2006/95/CEE British Standard EN 60335-1 (C 73800) 1 CONTENTS Page 1) INTRODUCTION 1.1) Description 3 1.2) Dimensions & connections

More information

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING

More information

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls Specification General The Powerex Laboratory Scroll Enclosed Air Compressor System is designed to provide clean, dry air for

More information

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a Air-Cooled Variable Speed Drive Screw Chillers Super Efficient Super Quiet Cooling Capacity Range 540-1405 kw R134a World s first low sound Air-Cooled variable speed drive screw chiller The recognition

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs next generation C precision controlled industrial process chillers cooling capacity: 6824 -,255,668 BTU /hr (0.6-04.6 tons) cooling capacity: 6,824 -,254,303 BTU/hr (0.6-04.5 tons) precision controlled

More information