Boiler and Its Tangential Fuel Firing System

Size: px
Start display at page:

Download "Boiler and Its Tangential Fuel Firing System"

Transcription

1 International Journal of Automation and Control Engineering (IJACE) Volume 3 Issue 3, August 2014 doi: /ijace Boiler and Its Tangential Fuel Firing System Sharukh khan & Shahabaz Khan Electronics & Communication Engineering & Electrical Engineering, SIND - JNTUH SIND- JNTUH, Andhra Pradesh, INDIA Sharukhan472@gmail.com, shahabaz100@gmail.com Abstract Boiler can also be called as the Burner.The main Function of the Boiler is to Burn the Fuel and Make Combustion possible. In this project we are going to study how coal is pulverized and burnt in order to gain more heat. Most coal fired power station boilers use pulverized coal. This technology is well developed, and there are thousands of units around the world, accounting for well over 90% of coal fired capacity. The coal is pulverized to a fine powder, so that less than 2% is +300 micro meter (μm) and % is below 75 microns, for a bituminous coal. This system has many advantages such as ability to fire varying quality of coal, quick responses to changes in load, use of high pre-heat air temperatures etc. One of the most popular systems for firing pulverized coal is the tangential firing using four burners corner to corner to create a fireball at the centre of the furnace. Keywords Rankine Cycle; Condenser; Dearator; Economiser; Reheater; Recipitator & Pulveriser Introduction A thermal power station works on the basic principle that heat liberated by burning fuel is converted into mechanical work by means of a suitable working fluid. The mechanical work is converted into electrical energy by means Of generator. In a steam power station, heat is realized by burning fuel, this heat is taken by water, which works as the working fuel. Water is converted into steam as it receives heat in the boiler. The steam then expands in turbine producing mechanical work, which is then converted into electrical energy through a generator. The exhaust steam from the turbine is then condensed in the condenser and the condensate is there after pumped to the boiler where it again receives heat and the cycle is repeated. The basic theoretical working cycle is of a steam power plant is THE RANKINE CYCLE. The modern steam power plant uses MODIFIED RANKINE CYCLE, which includes reheating, superheating and regenerative feed water heating. 71

2 International Journal of Automation and Control Engineering (IJACE) Volume 3 Issue 3, August 2014 Principle of Power Generation at Coal Based Power Plant The main function of oil and coal burning system is to convert chemical energy into heat energy, which is utilized by the components of the boiler to convert water into the steam, which drives the turbine. The combustion element of fuel consists of carbon, hydrogen and small amount of sulphur. The exhaust gases released after combustion contains CO2, SO2 and CO, etc. When the coal is burnt with oxygen following reaction takes place and large amount of heat is released. CC + OO 2 CCOO 2 SS + OO 2 SSOO 2 CC + OO 2 2CCCC The average composition of air is 79% nitrogen and 21% oxygen by volume 77% nitrogen and 23% oxygen by weight During combustion process nitrogen does not burn but passes through the chimney. The amount of air required to burn any fuel can be calculated if the amount of the elements present in the fuel are known. The amount of air to burn is known as theoretical air. If this quantity is not sufficient for complete combustion process then extra amount of air is supplied, known as excess air. In combustion process, turbulence, time, temperature and combustion efficiency are the important parameters to be considered. The maximum combustion efficiency depends on 1. Design of boiler 2. Fuel used 3. Skill in obtaining combustion within the minimum amount of excess air. Boiler (Steam Generator) Boiler or the steam generator is the main part in the power generation process. Boiler acts as a medium in which the water is converted into the steam by using the heat released in the process of combustion of coal in the presence of oxygen. Categorization of Boilers Boilers are generally categorized as follows: Steel boilers Fire Tube type Water tube type Horizontal Straight tube Bent tube Natural Circulation Positive Circulation Shell type Cast Iron Boilers Special Design Boilers Nuclear Reactors The steam generator is a natural circulation, single drum type, corner fired, and natural draft unit of water tube type. In water tube boiler, boiler feed water flows through the tubes and enters the boiler drum. The circulated water is heated by the combustion of gases and converted into steam at the vapor space in the drum. These boilers are selected when the steam demands as well as the steam pressure requirements are high as in the case of process cum power boilers. The steam generating boiler is designed for following conditions. 1. Main steam flow kg/hr. 2. Main steam pressure 157 kg/cccc 2 3. Main steam temperature 540 ºC 4. Reheat steam flow kg/hr. 5. Reheat steam temperature 540 ºC The features of water tube boilers are: Forced, induced and balanced draft provisions help to improve combustion efficiency. Less tolerance for water quality calls for water treatment plant. Higher thermal efficiency levels are possible. There are many mountings to the boiler, which are compulsory for the safe run of the boiler. Also, there are accessories, which increase the efficiency of the boile Arrangement of Main Boiler The illustration given in figure below shows a symbolic arrangement of various accessories of a Boiler. These accessories include 1. Economizer 2. Boiler drum 3. Down Comers 4. Water walls 5. Water wall platen (used for Low Pressure Boilers) 72

3 International Journal of Automation and Control Engineering (IJACE) Volume 3 Issue 3, August Primary super heater 7. Platen super heater 8. Final super heater 9. Reheater 10. Burner 11. Igniters Supporting Structures: Boilers supporting structure consists of a systematic arrangement of columns stiffened with horizontal beams and vertical diagonal bracings and comprise of Low carbon steel material. It is composed of 18 main columns and 12 auxiliary columns. The main columns support the main boiler components viz. drum, water wall, Membrane, panels, superheaters, Reheater, economizer s, air preheater, burners and galleries at various levels. The auxiliary columns, supports the boiler platforms and other ducts coming in that region.the total weight of supporting structures is about 970 M.T. Galleries and Stairways: Galleries and stairways around the combustion and heat recovery areas are provided for proper approach to the boiler. Stairways on both the side of boiler are provided. All the floors are covered with floor gratings of required depth for walkway and are tig welded to the structure. The total weight of Galleries and stairway are 900 M.T. Furnace FIG. SHOWING BOILER BLOCK DIAGRAM Boiler Structural: The boiler structural is divided into two parts. Supporting Structure Galleries and stair ways A boiler furnace is that space under or adjacent to a boiler in which fuel is burned and from which the combustion products pass into the boiler proper. It provides a chamber in which the combustion reaction can be isolated and confined so that the reaction remains a controlled force. In addition it provides support or enclosurefor the firing equipment FIG. SHOWING FURNACE INTERNAL STRUCTUR 73

4 International Journal of Automation and Control Engineering (IJACE) Volume 3 Issue 3, August 2014 Boiler Drum The function of steam drum is to separate the water from the steam generated in the furnace walls and to reduce the dissolved solid contents of the steam to below the prescribed limit of 1 ppm. The drum is located on the upper front of boiler. of radiant parallel flow type. The third stage superheater pendant spaced is of convection parallel flow type. The outlet temperature and pressure of the steam coming out from the superheater are 540 C and 157 Kg/Cm2 respectively for H.P.units. Economiser The purpose of economizer is to preheat the boiler feed water before it is introduced into the steam drum by recovering heat from the flue gases leaving the boiler. The Economiser is located in the boiler rear gas pass below the rear horizontal superheater. The economizer is continuous unpinned loop type and water flows in upward direction and gas in the downward direction. Reheater FIG. SHOWING SUPER HEATER OF BOILER The function of Reheater is to reheat the steam coming out from high pressure turbine to a temperature of 540 C. The Reheater is composed of two sections, the front pendant section and the rear pendant section. The rear pendant section is located above the furnace arc and the rear water wall and front pendant section is located between the rear water hanger tubes and the superheater platen section. FIG. SHOWING ECONOMIZER INTERNAL TUBES Super Heater There are three stages of superheater besides the side walls and extended sidewalls. The first stage consists of horizontal superheater of convection mixed flow type with upper and lower banks located above economizer assembly in the rear pass. The upper bank terminates into hanger tubes, which are connected to outlet header of the first stage superheater. The second stage superheater consists of pendant platen which is Burners FIG. SHOWING REHEATER WITH 600 NIPPLES There are total twenty four pulverized coal burners for corner fired C.E. type boilers and twelve oil burners provided each in between two pulverized fuel burner. 74

5 International Journal of Automation and Control Engineering (IJACE) Volume 3 Issue 3, August The pulverized coal burners are arranged in such a way that six mills Supply the coal to the burners at 4 corners, of the furnace. All the nozzles of the burners are inter Linked and can be tilted as a single unit from +30 to - 30.The oil burners are fed with heavy fuel oil till boiler load reaches to about 25%. boiler. The atomizing air for igniters is taken from plant air compressors at 7 Kg/cm2 (gauge). The burners are located at three elevations. Each elevation has four oil burners and igniters. These elevations are normally known as AB elevation, CD elevation and EF elevation. Igniters are used for lighting the main oil gun. There are two igniter air fans supply air for combustion of igniter oil. Mainly two types of igniters are used. 1. Eddy Plate Igniter 2. High Energy Arc Type Ignite FIG. SHOWING BURNER OF A BOILER Igniters There are twelve side eddy plate oil/h.e.a igniters per Boiler Auxilliaries FIG. SHOWING EDDY PLATE IGNITER 75

6 International Journal of Automation and Control Engineering (IJACE) Volume 3 Issue 3, August 2014 Coal Bunker These are in process storage silos used for storing crushed coal from the coal handling system. Generally, these are made up of welded steel plates. There are totally eight bunkers, four on each side of the boiler. Normally, there are six such bunkers supplying coal to the corresponding mills. These are located on top of the mills so as to aid in gravity feeding of coal. Coal Feeders Each mill is provided with a drag link chain/rotary/gravimetric feeder to transport raw coal from the bunker to the inlet chute, leading to mill at a desired rate. Mills There are six mill (25% capacity each), for every 200 MW unit, located adjacent to the furnace at '0' M level. These mills pulverize coal to the desired fineness to be fed to the furnace for combustion. P.A. Fan The primary air fans (2 per unit - 50% capacity each) are designed for handling atmospheric air up to a temperature of 50 ºC. These fans are located at 0 M level near the boiler. Air Pre-heater Air pre-heater transfers heat from flue gases to cold primary and/ or secondary air by means of rotating heating surface elements. Beneath these regenerative type air pre-heaters, there exists a steam coil air preheater. Wind Box These act as distributing media for supplying secondary/excess air to the furnace for combustion. These are generally located on the left and right sides of the furnace while facing the chimney. Electrostatic Precipitator These are generally two plate type located between boiler and the chimney. The precipitator is arranged for horizontal gas flow and is constructed with welded steel casings. ID Fans There are two induced draft fans per boiler located between the Electrostatic precipitator and the chimney. These fans are used for sucking flue gas from furnace. Chimney These are tall RCC structures with single/multiple flues (one flue per 200 MW Unit). The heights of these chimneys vary depending on the location considerations; anywhere between 150 m. to 220 m. Seal Air Fan These are used for supplying seal air to the mills to prevent ingress of coal dust into gear box lubrication oil. There are two fans per boiler for 200MW units. Soot Blowers These are located in the secondary pass of the furnace at a height of around 16 M level. Each 200 MW unit is provided with two such air pre-heaters. Burners As evident from the name itself, these are used for burning pulverized coal or oil. Every unit has a set of such burners located at different elevations of the furnace. F.D.Fan The forced draft fans (2 per unit - 50% capacity each) are designed for handling secondary air for the boiler. These fans are located at '0' M level near the PA Fan. FIG. SHOWING CORNER OF A TANGENTIAL BURNER Following three types of soot blowers, in requisite numbers, are provided: 76

7 International Journal of Automation and Control Engineering (IJACE) Volume 3 Issue 3, August i. Long retractable soot blowers ii. Wall blower iii. Air heater blower Superheated steam is tapped from super heater for the purpose of soot blowing. The pressure is reduced to 31 Kg/cm2 at 330 ºC by means of pressure reducing valve. The soot blowers are used for efficient on-load cleaning of furnace, super heaters, reheaters and regenerative air heaters. Fuel Firing System Most coal fired power station boilers use pulverized coal, and many of the larger industrial water tube boilers also use this pulverized fuel. This technology is well developed, and there are thousands of units around the world, accounting for well over 90% of coal fired capacity. The coal is pulverized to a fine powder, so that less than 2% is +300 micro meter (μm) and % is below 75 microns, for a bituminous coal. It should be noted that too fine a powder is wasteful of grinding mill power. On the other hand, too coarse a powder does not burn completely in the combustion chamber and results in higher unburnt losses. The pulverized coal is blown with part of the combustion. Air into the secondary boiler plant through 2 series of burner nozzles. Secondary and tertiary air may also be added. Combustion takes place at temperatures from ºC, depending largely on the coal grade. Particle residence time in the boiler is typically ₐ to 5 seconds, and the particles must be small enough for complete combustion to have taken place during this time.this system has many advantages such as ability to fire varying quality of coal, quick responses to changes in load, use of high pre-heat air temperatures etc. One of the most popular systems for firing pulverized coal is the tangential firing using four burners corner to corner to create a fireball at the center of the furnace. Fuels There are two types of fuels which play a vital role in fuel firing system. They are: 1. Coal 2. Oil Coal Fuel (coal) is fed from mines to the boiler through the fuel feeding plant commonly known as Coal handling plant. Selection of proper methods of coal supply from the mines to the power station depends upon the system capacity in the tons/hour, location of available outsides storage and overhead coal bunkers. The unloading will take place by Merry Go Round system in which loading and unloading will take place within minutes. Coal is crushed to the sizes of 25mm in the crusher house before it is fed to the bunkers of individual units. The coal from CHP is transferred to the bunkers through the conveyer belts via turning points. The storage capacity of bunkers in terms of time is 14 hours. The coal from the bunkers enters the mills through the coal feeders by gravity action. The quantity of coal reaching the coal mill is controlled by feeders by altering the speed of DC motors as per the requirements of the unit. Coal Bunker These are in process storage silos used for storing crushed coal from the coal handling system. Generally, these are made up of welded steel plates. Normally, there are six such bunkers supplying coal of the corresponding mills. These are located on top of the mills so as to aid in gravity feeding of coal. Coal Feeders In most of the power stations the types of feeders used for transporting coal from Raw Coal bunker to the mills are: 1. Volumetric feeders 2. Gravimetric type feeders Mills Pulverised fuel firing is a method whereby the crushed coal, generally reduced to fineness such that 70-80% passes through a 200 mesh sieve, is carried forward by air through pipes directly to burners or storage bins from where it is passed to burners. When discharged into combustion chamber, the mixture of air and coal ignites and burns in suspension. The economic motives for the introduction and development of pulverised fuel firing are: 77

8 International Journal of Automation and Control Engineering (IJACE) Volume 3 Issue 3, August 2014 i. Efficient utilization of cheaper low grade coals. ii. iii. iv. Flexibility in firing with ability to meet fluctuating loads. Elimination of banking losses. Better reaction to automatic control. v. Ability to use high combustion air temperature; increasing the overall efficiency of boiler. vi. High availability. The only disadvantage is that the initial cost of equipment for preparation of pulverised coal will be high. c) Low sulphur heavy stock (LSHS). The boiler is equipped with equipment for heavy oil firing at elevation AB, CD and EF. Heavy oil guns are used for stabilizing flame at low load carrying. Warm up oil guns are used for cold boiler warm up during cold start up and igniter are used for start-up and oil flame stabilizing. This system requires maximum total output of the oil burners is 30% of the boiler MCR heat input with HFO and 7.5 % of the boiler MCR heat input with LFO. This corresponds to synchronisation needs before firing coal burners. For the preparation of fuel oil, pumping the oil and heating are the major preparatory functions to remove any dust, dirt, sediment, sludge, etc. Fuel oil atomisation is the process of spraying the fuel oil into fine mist for better mixing of fuel with combustion air. By passing through the spray nozzles of the oil gun, the pressure Energy of the oil converts into fine particles. Fuel Data Oils A coal fired unit incorporates oil burners to a firing capacity of 30% of boilers load for following reasons: a) To provide necessary ignition energy to light off coal burner. b) To stabilise the coal flame at low boiler/burner loads. c) As a safe start-up fuel and for controlled heat input during light off. The types of oil used in the oil burners are: a) Light Diesel Oil b) Heavy fuel oil Firing Systems: This can be broadly classified into direct firing system and indirect firing or intermediate bunker system. Both the systems can use any type of mill. Either hot gas or air can be used for drying and transporting the coal. Direct Firing System In this type of firing system, coal is fed to the mill at controlled quantity. Hot air whose temperature 78

9 International Journal of Automation and Control Engineering (IJACE) Volume 3 Issue 3, August can be controlled with the help of cold air is permitted to flow through the mill. The air dries the coal and picks up the milled product and flows through the classifier where higher size particle is rejected back to the mill. The fine coal is carried by the air through the coal burner to the combustion chamber. The flow through the system is carried out by primary air fan or by exhauster. In case of hammer mills forced draft itself can do the purpose of primary air fan. This system is simple involving minimum equipment hence minimum initial cost and maintenance cost. As there is no fine coal storage the mill load is varied according to the boiler load. Hence part load operation of mill is essential and this means increase in power consumption and maintenance per tonne of coal. Mill outage will result in reduction of boiler output if spare mills are not provided or available. This is best suited to use with high speed and medium speed mills as the mill power consumption varies in direct proportion to the mill load. Tube ball mills with this system is also used but to a limited extent. Indirect Firing System In this system, mills are operated independent of boiler loading and pulverised coal is stored in the intermediate bunker. From the bunker it is taken to combustion chamber with the help of primary air fan. Boiler loading is controlled by the amount of pulverised fuel fed to boiler. Hot air or gas is used for drying and transporting. Cyclone type separators are used to separate the fine coal from coal, air/gas mixture for storing in fine coal bunker. As fine coal dust cannot be completely removed by cyclone type separators, a certain portion of very fine particle is carried along by air/vapour. This necessitates admissions of vapour/air into the combustion chamber to utilise the heating value of fine coal dust carried along with vapour/air. This can be done by providing separate vapour burners or the air can be used as primary air for carrying the fine coal. This system using gas as drying medium requires one additional can called vapour fan for each mill. If air is used for drying, one fan called mill fan can be designed to carry out both the functions of primary air fan and vapour fan. This system favours the following advantages: a) Mill can be operated always at full load, thus saving in power, maintenance cost per tonne of coal for the selected mill. Hence this system is adopted normally for tube ball mill. b) Separate spare mill is not necessary for carrying out the maintenance. Certain percentage as spare capacity on total basis is normally enough. c) Mills can be operated during off peak hours only and hence higher power out during the peak period. Methods of Fuel Firing There are many ways of firing the coal in furnace. They are: a) Vertical firing b) Horizontal firing c) Impact firing d) Corner or tangential firing Vertical Firing In vertical firing, a number of rectangular fan shaped nozzles are set across the width of the furnace in an arc immediately under the boiler setting. The pulverised fuel mixture ignites under the arc and is directed vertically downwards to the bottom of the furnace where the gases are made to turn upwards to pass through the combustion chamber this gives a long path to the flame and is particularly suitable for coals of low volatile content. Horizontal Firing (Front Firing) Horizontal firing with the turbulent type of burner is set up usually in the front (front wall fired) or rear walls of the furnace. This burner consists of an inner cone for primary air and fuel which is given a rotary motion as it passes through the burner. This mixes with a stream of rotating secondary air before burning. Impact Firing This is the arrangement with the type of burner used with slag tap furnaces where the ash is kept in a molten state on the furnace floor and tapped off as and 79

10 International Journal of Automation and Control Engineering (IJACE) Volume 3 Issue 3, August 2014 when necessary. Corner or Tangential Firing Tangential firing is a method of firing a fuel to heat air, which is the most common one in thermal power Stations.The flame envelope rotates ensuring thorough mixing within the furnace, providing complete combustion and uniform heat distribution. The most effective method for producing intense turbulence is by the impingement of one flame on another. This action is secured through the use of burners located in each of the four corners of the furnace, close to the floor or the water-screen. The burner nozzles are so directed that the streams of coal and air are projected along a line tangent to a small circle, lying in a horizontal plane, at the centre of the furnace. Intensive mixing occurs where these streams meet. A scrubbing action is present which assures contact between the combustible and oxygen, thus promoting rapid combustion and reducing carbon loss. A relative motion, similar to that of a cyclone, is imparted to the flame body, which spreads out and fills the furnace area. The ignition at each burner is aided by the flame from the preceding one. With tangential firing the furnace is essentially the burner, consequently air and coal quantities need not be accurately proportional to the individual fuel nozzle assemblies. Turbulence produced in the furnace cavity is sufficient to combine all the fuel and air. This continuously insures uniform and complete combustion so that test performance can be maintained throughout daily operation. With other types of firing the fuel and air must be accurately proportioned to individual burners making it difficult to always equal test results. With this type of firing, combustion is extremely rapid and short flame length results. The mixing is so intense that combustion rates exceeding 35,000 Btu/ (ft 3 h) or 360 kw/m 3 are practical under certain conditions. However, since there is considerable impingement of flame over the furnace walls it is absolutely necessary that they be fully watercooled. This sweeping of the water-cooled surfaces, in the furnace, by the gas increases the evaporation rate. Thus, in addition to absorption by radiation from the flame envelope, there is transfer by convection, and the resulting furnace temperatures are lower than with other types of burners, even though the heat liberation rates may be somewhat higher. Tangentially-fired furnaces are usually clean in the upper zone and, as a result, both the furnace and the boiler are comparatively free from objectionable slag deposits. Brief Explanation of Tangential Fuel Firing System In this system, burners are set at each corner of the furnace and are directed to strike the outside of an imaginary circle in the centre of the furnace. Because the streams of fuel so strike each other, extremely good mixing is obtained. Since the body of the flame produced is given a rotary motion it leads to a longer flame travel and the gases spread out-and flows through combustion chamber. Burners and Burner Arrangement Coal burners mainly comprise of coal nozzle, steel tip, seal plate and tilting link mechanism. These are housed in coal compartment in all four corners of the furnace and connected with coal pipes. Coal nozzle's one end (outlet) is rectangular and another end is cylindrical. The rectangular end which forms the nozzle is connected with nozzle tip by pivot pin. The tip can be tilted on this pivot. The nozzle tip is divided into several sectors to form separate coal and air 80

11 International Journal of Automation and Control Engineering (IJACE) Volume 3 Issue 3, August passages. Again coal and air passages are divided into several parts for uniform distribution of flow. To seal the air and coal passage a seal plate is provided. Oil Burner Design Considerations The essential requirements for an oil burner design are: a) It must completely atomise the oil without -drooling, fouling or clogging. b) The jet must be so shaped that it will completely mix with the air necessary for combustion. c) Maintenance of atomisation over a comparatively wide capacity range. d) Combustion must be complete and excess air at a minimum over the entire operating range. e) A ready accessibility for effecting repairs, thereby minimising burner outage as well as maintenance costs. c) Mechanically atomised burners Air Atomising System The air atomising system uses compressed air at 7 kg/ sq.cm. The quantity of air required depends on design of burner, degree of atomisation required, grade of oil, its pressure and temperature. The air used in the system should be free of condensate. Air atomising systems are not recommended for heavy oil system as they tend to chill the oil and decrease atomisation quality. The guns used in this system have two main components for atomisation. They are: a) Mixing plate b) Spray Plate. The role of mixing plate is to mix the air and oil properly and the role of spray plate is to inject this mixture uniformly into the furnace. Mechanical Atomisation Oil under pressure is supply to the burner gun and enters the atomiser tip through slots cut tangentially to the periphery of the Whirling. The drop pressure is converted into velocity causing the oil to enter the whirling chamber at a very high speed, thus establishing a rapid rotation of the oil in the whirling chamber. Atomisation Atomisation breaks the fuel into fine particles that readily mixes with the air for combustion. Oil should be divided up into small particles for effective atomisation. The advantages of atomisation are: a) Atomising burners can be used with heavier grades of oil. b) Can be adopted to large applications because of large capacity range. c) Complete combustion.is assured by the ability of the small particles to penetrate turbulent combustion. Classification Oil burners are classified according to the method used for atomization, as follows: a) Air-atomised burners b) Steam-atomised burners Since the mechanical atomisation oil guns are limited in range they are generally selected for boiler operating at fixed loads. Steam Atomisation This system uses auxiliary steam to assist in the atomisation of the oil. The steam used in this method should be slightly superheated and free of moisture. As in the air atomising system, the steam used for atomising as well as the fuel pass through the tip and into the furnace. The main advantages of steam atomising burners over other are: a) Simplicity of its design b) Initial cost of installation is low c) Low pumping pressure d) Low preheating temperature. The only disadvantage is the steam consumption in burners. Refer the figure below for air / steam atomised oil gun compartment with wind box assembly. 81

12 International Journal of Automation and Control Engineering (IJACE) Volume 3 Issue 3, August 2014 Burner Arrangement There are twenty four pulverised coal burners arranged on the corners at a height of 18 to 25 meters and twelve oil burners provided each in between two pulverised fuel burners. The pulverised coal burners are arranged in such a way that six mills supply the coal to burners at 4 corners, of the furnace, all the nozzle of the burners are inter linked and can be tilted as a single unit from +30 deg. to -30 degree. The oil burners are fed with heavy fuel oil till boiler load reaches to about 25%. There are four wind boxes fixed at 4 corners of the furnace. There are 13 nozzles in each wind box 6 for coal and 7 for air. In tangentially fired boilers, four tall wind boxes are arranged at each corner of the furnace. The coal burners are located at different elevations of wind boxes. The numbers of coal nozzles elevations are equivalent to the number of coal mills. The same elevations of coal nozzles at four corners are fed from a single coal mill. The coal nozzle is sandwiched between air nozzles or compartments. That is, nozzles are arranged between coal nozzles, one below the bottom coal nozzle and above the top coal nozzle. If there are n numbers of coal nozzles per corner there will be (n+1) number of air nozzles per corner. The coal fuel and combustion air streams from these nozzles directed tangential to imaginary circle at the center of the furnace. This creates turbulent vortex motion of the fuel, air and the hot gases which promotes the mixing, ignition energy availability and thus combustion efficiency. All the nozzles of the burners are interlinked and can be tilted as a single unit from +30º to -30º. The air nozzles in between are termed as Auxiliary air nozzles, and the topmost and the bottommost air nozzles are termed as End air nozzles. The coal nozzles elevations are designed as A, B, C, D, E, F, G, and H from bottom to top, the bottom end air nozzles as AA, and the top end air nozzles as HH. The auxiliary air nozzles are designated by the adjacent coal nozzles as, like AB, BC, CD, DE, EF, FG, GH and HH from bottom to top. The four furnace corners are designated as 1, 2, 3 and 4 in clockwise direction looking from the top, and counting front water wall left corner as 1, as shown in the figure below. Each pair of coal nozzle elevation is served by one elevation of oil burners located in between the auxiliary air nozzles. In this with the eight mills or eight elevations of coal nozzles, there are 16 oil guns arranged in four elevations at auxiliary air nozzles at AB, CD, EF and GH. Heavy fuel oil can be fired at the oil gun elevations and L.D.O can be fired only in AB elevation. Each oil gun is associated with an igniter arranged at the side. 82

13 International Journal of Automation and Control Engineering (IJACE) Volume 3 Issue 3, August Typical Corner Arrangement for a Tangentially Fired System S.NO CORNER -1, 2, 3, 4 MILLS 1 H H AIR 2 H COAL 3 G H OIL G H 4 G COAL 5 F G AIR 6 F COAL 7 E F OIL E F 8 E COAL 9 D E AIR 10 D COAL 11 C D OIL C D 12 C COAL 13 B C AIR 14 B COAL 15 A B OIL A B 16 A COAL 17 A A AIR Coal Nozzel Nozzle are the place from where primary air and coal sent to Boiler. In a power Station there are two type of coal nozzle used. 1) Impellor: - Impellor type nozzle is used in first stage unit. It is based on Italian design. Oil gun is used in impellor type nozzle In impellor the upper side is diamond shaped. The length of impellor is 1900 mm no electrode rod is used for welding in impellor type nozzle. For patching 6013 no electrode rod is used. 2) Tangential: - Tangential coal nozzle is used in 4 th, 83

14 International Journal of Automation and Control Engineering (IJACE) Volume 3 Issue 3, August th, 6 th and 7 th unit.it is used in corner firing. Details of Nozzle Weight: The weight of nozzle is 991kg. Length: Tip to nozzle is 2400mm. Tip: Tip of nozzle is 800mm square Nozzle Outer Diameter: The outer diameter of nozzle is 640mm. Filler 1 IGNITER GUNS 4 X 8 = 32 2 OIL GUNS 4 X 4 = 16 3 COAL BURNERS 4 X 8 = 32 4 SCANNERS IR (COAL) 4 X 4 = 16 5 SCANNERS UV (OIL) 4 X 4 = 16 Cobal Arc is used as filler. For metallic filler 7018 no electrode rod is used. For joining divider 604 no electrode rod is used. For welding stainless steel 308 and309 no electrode rod is used. For making diamond shape 604 no electrode rod is used for preventing from erosion. Cost of Tangential Coal Nozzle The cost of one tangential coal nozzle is Rs Cost of one nozzle = Rs Total no of nozzle used in one boiler = 32 Hence, total cost = 32x = Rs The cost for repairing one nozzle is approximately Cost of repairing one nozzle = Rs Total no of nozzle = 32 Hence, total repairing cost = Rs As for new nozzle Rs is required and its life is 2 years. But for repairing it costs Rs. Hence saving = = Rs. Conclusion A thorough examination and keen study on the various fuel igniters, burners and the fuel firing systems have been observed in UNIT 4 & 5 of stage II in RSTPS. In addition, we have also observed the various flow processes taking place in the boiler and its auxiliaries. REFERENCES Wikipedia Few other sources available online Total number of nozzle used in one boiler is

Boiler Basics. Design and operation

Boiler Basics. Design and operation Boiler Basics Design and operation A boiler is an enclosed vessel that provides a means for combustion heat to be transferred into water until it becomes heated water or steam. The hot water or steam under

More information

MODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel.

MODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel. MODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) Q 1. a) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel. 2) steam turbine- It is a device that extract

More information

WHAT IS A BOILER? BOILER IS AN EQUIPMENT WHICH PRODUCES STEAM AT THE REQUIRED PRESSURE AND TEMPERATURE. BOILER DESIGN, MANUFACTURE & INSTALLATION ARE

WHAT IS A BOILER? BOILER IS AN EQUIPMENT WHICH PRODUCES STEAM AT THE REQUIRED PRESSURE AND TEMPERATURE. BOILER DESIGN, MANUFACTURE & INSTALLATION ARE Your Logo Here TRAINING ON BOILERS PRESENTED AT M/S. MAGADI SODA COMPANY, MAGADI, KENYA LIMITED 1 WHAT IS A BOILER? BOILER IS AN EQUIPMENT WHICH PRODUCES STEAM AT THE REQUIRED PRESSURE AND TEMPERATURE.

More information

Boiler. Fire tube Boiler:

Boiler. Fire tube Boiler: Boiler What is Boiler? A closed metallic vessel in which the water is heated beyond the boiling temperature by the application of heat by the combustion of fuels to convert it into steam. The function

More information

APPLICATION PROFILE EXPLOSIONS IN CEMENT PLANTS EXPLOSIONS IN CEMENT PLANTS CEMENT PLANT EQUIPMENT WITH HIGHEST EXPLOSION POTENTIAL. Form No.

APPLICATION PROFILE EXPLOSIONS IN CEMENT PLANTS EXPLOSIONS IN CEMENT PLANTS CEMENT PLANT EQUIPMENT WITH HIGHEST EXPLOSION POTENTIAL. Form No. APPLICATION PROFILE EXPLOSIONS IN CEMENT PLANTS Cement manufacturing is one of the largest mineral commodity industries in the United States, with an estimated production capacity of greater than 73 million

More information

Sootblowers. Learning Outcome. Learning Objectives. When you complete this module you will be able to: Discuss sootblowers.

Sootblowers. Learning Outcome. Learning Objectives. When you complete this module you will be able to: Discuss sootblowers. Sootblowers Learning Outcome When you complete this module you will be able to: Discuss sootblowers. Learning Objectives Here is what you will be able to do when you complete each objective: 1. Describe

More information

AUTOMATION OF BOILERS USING LABVIEW

AUTOMATION OF BOILERS USING LABVIEW I J L S C M 4(1), 2012, pp. 49-53 AUTOMATION OF BOILERS USING LABVIEW A. MICHAEL SIDDHARTHA AND S. NAVEEN KUMAR Under Graduate Student, Department of Electronics and Communication Engineering Thiagarajar

More information

Solution of I Mid Term Steam Engineering 6ME5A

Solution of I Mid Term Steam Engineering 6ME5A 1(a) Discuss the working principle of LaMont high pressure boiler This boiler works on basic principle of forced convection. If the water is circulate by a pump inside the tube, the heat transfer rate

More information

CHAPTER 2: PROPERTIES OF STEAM AND STEAM POWER

CHAPTER 2: PROPERTIES OF STEAM AND STEAM POWER CHAPTER 2: PROPERTIES OF STEAM AND STEAM POWER Steam produced from water forms one of the most important working fluids in engineering energy conversion systems. The advantages of using steam (water) as

More information

PESIT-Bangalore South Campus

PESIT-Bangalore South Campus USN PESIT Bangalore South Campus Hosur road, 1km before Electronic City, Bengaluru -560-100 Department of Mechanical Engineering INTERNAL ASSESSMENT TEST 2 Date : 03/04/2018 Max Marks : 50 Subject & Code

More information

Module 5: Combustion Technology. Lecture 38: Combustion Burners

Module 5: Combustion Technology. Lecture 38: Combustion Burners 1 P age Module 5: Combustion Technology Lecture 38: Combustion Burners 2 P age Keywords : Atmospheric burner, atomizer, rotating cup burner, swirl type burner, nozzle design 5.7 Combustion Burners Types

More information

Boiler Draft Equipment

Boiler Draft Equipment Boiler Draft Equipment Learning Outcome When you complete this module you will be able to: Discuss, sketch and describe the basic equipment used to supply combustion air to a boiler furnace. Learning Objectives

More information

CHP-turbine room. CHP can capture almost EXTRACTED STEAM 20 PSI HIGH-PRESSURE STEAM 1250 PSI HEAT EXCHANGER HOT WATER SUPPLY F

CHP-turbine room. CHP can capture almost EXTRACTED STEAM 20 PSI HIGH-PRESSURE STEAM 1250 PSI HEAT EXCHANGER HOT WATER SUPPLY F 5 6 HIGH-PRESSURE STEAM is routed from the wood-chp boiler to the turbine. TURBINE BLADES spin at nearly 00 revolutions per second. Steam acting on the turbine blades creates mechanical energy in the TURBINE.

More information

OPTIMISATION OF SOOT BLOWER OPERATION IN BOILER TO IMPROVE EFFICIENCNY

OPTIMISATION OF SOOT BLOWER OPERATION IN BOILER TO IMPROVE EFFICIENCNY OPTIMISATION OF SOOT BLOWER OPERATION IN BOILER TO IMPROVE EFFICIENCNY K.Vijay 1, Dr. B. Karthikeyan 2 1PG Student, Department of Mechanical Engineering, Annamalai University, chidambaram. 2Associate professor,

More information

Problem Cause Remedial action. Gauge glass There was excess chemical dosage The normal ph recommended was 9.5 to See photo 3 & 4.

Problem Cause Remedial action. Gauge glass There was excess chemical dosage The normal ph recommended was 9.5 to See photo 3 & 4. CASE STUDIES OF STEAM SYSTEM AUDIT IN SOME PLANTS By K.K.Parthiban, Venus Energy Audit System Introduction This article outlines the outcome of auditing of steam system conducted in process Industries.

More information

ROTARY DRYER CONSTRUCTION

ROTARY DRYER CONSTRUCTION ROTARY DRYER The Rotary Dryer is a type of industrial dryer employed to reduce or to minimize the liquid moisture content of the material it is handling by bringing it into direct contact with a heated

More information

Attention is drawn to the following places, which may be of interest for search:

Attention is drawn to the following places, which may be of interest for search: CPC - F22B - 2017.02 F22B METHODS OF STEAM GENERATION; STEAM BOILERS (steam engine plants where engine aspects predominate F01K; domestic central-heating systems using steam F24D; heat exchange or heat

More information

B.Tech. First Semester Examination Basics of Mechanical Engineering (ME-101F)

B.Tech. First Semester Examination Basics of Mechanical Engineering (ME-101F) B.Tech. First Semester Examination Basics of Mechanical Engineering (ME-101F) Q. 1. (a) Differentiate between water tube boiler and fire tube boiler. Ans. Comparison Between 'Fire-tube and Water tube'

More information

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass Product of Quality Best Performance Ball Float Controlled Steam Traps Auto Drain Traps Float Valve Air Vent Valves Feed Control Valve Drain Control Valve Thermo Dynamic(TD) Trap Safety Valve Condensate

More information

THERMAL ENGINEERING & GAS DYNAMICS ME-6002

THERMAL ENGINEERING & GAS DYNAMICS ME-6002 SAGAR INSTITUTE OF RESEARCH & TECHNOLOGY, BHOPAL DEPARTMENT OF MECHANICAL ENGINEERING THERMAL ENGINEERING & GAS DYNAMICS ME-6002 1 UNIT I STEAM GENERATOR SYLLABUS Steam generators: classification, conventional

More information

The equipment and materials shall be designed and constructed in accordance with the ASME code section I 2001 ED A02 and Chinese Standards.

The equipment and materials shall be designed and constructed in accordance with the ASME code section I 2001 ED A02 and Chinese Standards. Steam Boiler Type S50-3.82/450 Traveling grate stoker 50t/h x 3.82 pa x 450 Degree C 1. Basic use of the boiler The boiler can be used for industrial power generation, or thermal power station for enterprises

More information

There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are:

There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are: Heating of Crude Oil 1.Introduction: There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are: Heat Exchangers. Tube Still Heaters (Furnaces).

More information

Steam Fundamentals. (in heating & processing applications)

Steam Fundamentals. (in heating & processing applications) Steam Fundamentals (in heating & processing applications) Introduction Common Heat Energy conveyers: Thermal Oil Hot water Steam Electrical Electric Heaters Electrodes (High Current) Steam Fundamentals

More information

2x58 MW Coal Fired Power Plant at Mauritius

2x58 MW Coal Fired Power Plant at Mauritius 2x58 MW Coal Fired Power Plant at Mauritius The coal-fired power plant produces electricity by the burning of coal and air in a Circulating Fluidized Bed Combustion Boiler (CFBC), where it heats water

More information

PIPING SYSTEM EQUIPMENTS

PIPING SYSTEM EQUIPMENTS PIPING SYSTEM EQUIPMENTS Introduction Equipments are devices that provide power, process and store materials. Equipments in piping systems depend on the specific industries using them. Specialized equipment

More information

TMCI Padovan Evaporators

TMCI Padovan Evaporators TMCI Padovan Evaporators Evaporators Our range includes 4 types of evaporators: Forced Circulation Falling Film Evaporators Plates Thin Film Concentration systems Evaporator choosing criteria: product

More information

PERFORMANCE EVALUATION AND RECURRING JAMMING PROBLEM ANALYSIS OF AIR PREHEATER IN COAL-FIRED POWER PLANTS

PERFORMANCE EVALUATION AND RECURRING JAMMING PROBLEM ANALYSIS OF AIR PREHEATER IN COAL-FIRED POWER PLANTS PERFORMANCE EVALUATION AND RECURRING JAMMING PROBLEM ANALYSIS OF AIR PREHEATER IN COAL-FIRED POWER PLANTS M.Srinivasa Rao M.Tech Student, Department of Mechanical Engineering, GMRIT, Srikakulam, AP, India.

More information

HEAT EXCHANGE IN GENERAL

HEAT EXCHANGE IN GENERAL XXXX F28 HEAT EXCHANGE IN GENERAL Note(s) (1) In this class, the following expressions are used with the meanings indicated: heat exchange means the heating or cooling of a fluid or fluent solid by direct

More information

ASSSIGNMENT 3. Textbook Assignment: Boilers, chapter 4, pages 4-1 through 4-15, and Steam Turbines, chapter 5, pages 5-1 through 5-1.

ASSSIGNMENT 3. Textbook Assignment: Boilers, chapter 4, pages 4-1 through 4-15, and Steam Turbines, chapter 5, pages 5-1 through 5-1. ASSSIGNMENT 3 Textbook Assignment: Boilers, chapter 4, pages 4-1 through 4-15, and Steam Turbines, chapter 5, pages 5-1 through 5-1. 3-1. What is the function of a boiler in the steam cycle? 1. To convert

More information

FLUIDIZED BED BOILERS

FLUIDIZED BED BOILERS FLUIDIZED BED BOILERS Proven technology for burning fuels on solid grate with a fountain fluidized layer; The possibility of burning a wide variety of solid fuels - with large heated value range coal,

More information

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful Harnessing Energy Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful Vapor Power Cycle The vast majority of electrical generating plants are variations of vapor power

More information

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS 6.1 Types of Heating Systems 6.2 Heating Energy Sources 6.3 Furnaces and Air Heaters 6.4 Boilers 6.5 District Heating 6.6 Selection of Medium- Steam

More information

ecodry Figure 1 - Process Diagram ecodry B General Process Description

ecodry Figure 1 - Process Diagram ecodry B General Process Description ecodry The process principal of the ecodry system is centered around the concept of drying in a closed steam loop, with a process-integrated thermal oxidation. The separation of flue gas from the drying

More information

BHEL Steam Generators Material Selection Overview by Veerendar Aluvala DM/BHEL/Trichy

BHEL Steam Generators Material Selection Overview by Veerendar Aluvala DM/BHEL/Trichy BHEL Steam Generators Material Selection Overview by Veerendar Aluvala DM/BHEL/Trichy Presentation Summary Pulverised Coal Combustion (PCC) Design Aspects Boiler Parameters Drum Type Boilers OTSC Boilers

More information

MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers

MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING Sample Questions and Answers CHAPTER 5 EVAPORATORS 1. What is Evaporator? Classify the various types of evaporator. Evaporator

More information

Boiler Technical Specifications (2013)

Boiler Technical Specifications (2013) ACT Bioenergy Boiler Dimensions 0.5-0.85 Million Btu/h (150-250kW) Model CP500 CP600 CP750 CP850 Heat Output in MBtu/h (kw) 510 (150) 610 (180) 750 (220) 850 (250) Height ft (mm) 6 1 (1855) 6 1 (1855)

More information

ANNEXURE 1 KEY PLAN. Project site. Application Form 1 for Amendment in Environmental Clearance for M/s. Windson Chemical Pvt. Ltd.

ANNEXURE 1 KEY PLAN. Project site. Application Form 1 for Amendment in Environmental Clearance for M/s. Windson Chemical Pvt. Ltd. ANNEXURE 1 KEY PLAN Project site Application Form 1 for Amendment in Environmental Clearance for M/s. Windson Chemical Pvt. Ltd. 18 ANNEXURE 2 PLANT LAY-OUT Application Form 1 for Amendment in Environmental

More information

Development of Boiler Design

Development of Boiler Design Development of Boiler Design Learning Outcome When you complete this module you will be able to: Discuss historical developments of, and the general requirements for proper boiler design. Learning Objectives

More information

Document Code: 1 (15) Issuing date: Status:

Document Code: 1 (15) Issuing date: Status: Document Code: 1 (15) Project : MULTI FUEL CFB BOILER SIMULATOR Author: Approved: Language: HSK Document title: SYSTEM DESCRIPTION BOILER WATER SYSTEM Submitted for: Customer reference: Other information:

More information

When you complete this module you will be able to: Describe various watertube boiler designs, including large generating units.

When you complete this module you will be able to: Describe various watertube boiler designs, including large generating units. Watertube Boilers Learning Outcome When you complete this module you will be able to: Describe various watertube boiler designs, including large generating units. Learning Objectives Here is what you will

More information

DELTA-TE III. Nozzle-mix line burner

DELTA-TE III. Nozzle-mix line burner 4-21.7-1 DELTA-TE III Nozzle-mix line burner Combines excellent flexibility with extreme low emissions for direct firing Especially designed for firing in low oxygen, high humidity and/or inert process

More information

Department of Mechanical and Production Engineering Ahsanullah University of Science and Technology (AUST) Lab Manual on ME 4202

Department of Mechanical and Production Engineering Ahsanullah University of Science and Technology (AUST) Lab Manual on ME 4202 Department of Mechanical and Production Engineering Ahsanullah University of Science and Technology (AUST) Lab Manual on ME 4202 Applied Thermodynamics Sessional Credit Hours: 0.75 General Guidelines:

More information

PROFILE AMBICA. Multi Fuel Three Pass, Fire Cum Water Tube Steam Boiler Mfg. Range From 0.5 TPH to 35 TPH Working Pressure up to 50Kg / cm2

PROFILE AMBICA. Multi Fuel Three Pass, Fire Cum Water Tube Steam Boiler Mfg. Range From 0.5 TPH to 35 TPH Working Pressure up to 50Kg / cm2 PROFILE AMBICA B O I L E R www.ambicaboilers.com Multi Fuel Three Pass, Fire Cum Water Tube Steam Boiler Mfg. Range From 0.5 TPH to 35 TPH Working Pressure up to 50Kg / cm2 Company Pro le We are a reputed

More information

Glass Wool Production Line

Glass Wool Production Line Glass Wool Production Line Glass wool is a kind of insulation materials which is made of natural ores, such as quartzite, dolomite, feldspar, limestone and so on. With the features of low density, convenient

More information

1. Raw Material Handling: 2. Roaster Furnace: 4. Waste Heat Boiler: 5. Boiler Chain Conveyors:

1. Raw Material Handling: 2. Roaster Furnace: 4. Waste Heat Boiler: 5. Boiler Chain Conveyors: 1. Raw Material Handling: The concentrate storage capacity is 40,000 MT and day bins are having 3 x 400 MT capacity. 2. Roaster Furnace: The Roaster is having 77 Sqr.Mtr hearth area of M./s Lurgi make

More information

Coal Handling and Processing. Advanced Solutions for Coal-Related Environmental Dust Control. Better Air is Our Business

Coal Handling and Processing. Advanced Solutions for Coal-Related Environmental Dust Control. Better Air is Our Business Coal Handling and Processing Advanced Solutions for Coal-Related Environmental Dust Control Better Air is Our Business Coal Handling and Processing Industry Leader Our Qualifications For more than 85 years,

More information

Boiler Division HPS. Triveni Boiler

Boiler Division HPS. Triveni Boiler HPS Three Pass, Fire & Water Tube Steam Boiler From 1 Ton / hour to 36 Ton / hour Steam Production Capacity & up to 50Kg Triveni Boiler Triveni Boiler Triveni Boiler Pvt. Ltd. Boiler Division Company Profile

More information

MECHANICAL SCIENCE Module 2 Heat Exchangers

MECHANICAL SCIENCE Module 2 Heat Exchangers Department of Energy Fundamentals Handbook MECHANICAL SCIENCE Module 2 Heat Exchangers Heat Exchangers DOE-HDBK-1018/1-93 TABLE OF CONTENTS TABLE OF CONTENTS LIST OF FIGURES... ii LIST OF TABLES... iii

More information

CHAPTER 3 BASIC STEAM CYCLE

CHAPTER 3 BASIC STEAM CYCLE CHAPTER 3 BASIC STEAM CYCLE To understand steam generation, you must know what happens to the steam after it leaves the boiler. A good way to learn the steam plant on your ship is to trace the path of

More information

Boiler Mountings. Engr. Omar Sadath, Maritme Lecturer & Trainer, Bangladesh

Boiler Mountings. Engr. Omar Sadath, Maritme Lecturer & Trainer, Bangladesh Boiler Mountings Engr. Omar Sadath, Maritme Lecturer & Trainer, Bangladesh overview Mountings are crucial without which the operation of boilers is unsafe. Proper maintenance and care of the mountings

More information

COOPERATIVE PATENT CLASSIFICATION

COOPERATIVE PATENT CLASSIFICATION CPC F COOPERATIVE PATENT CLASSIFICATION MECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING (NOTE omitted) LIGHTING; HEATING F28 HEAT EXCHANGE IN GENERAL (NOTES omitted) F28D HEAT-EXCHANGE APPARATUS,

More information

WATER TUBE SOLID FUEL SERIES YOSHIMINE CO., LTD

WATER TUBE SOLID FUEL SERIES YOSHIMINE CO., LTD YOSHIMINE WATER TUBE BOILERS SOLID FUEL SERIES YOSHIMINE CO., LTD Yoshimine Boilers Proven Quality Worldwide Since its foundation in 1937, Yoshimine has been specializing in the development and manufacture

More information

BOILER CLEANING SYSTEMS. for Improved Availability of Waste Incineration Boilers

BOILER CLEANING SYSTEMS. for Improved Availability of Waste Incineration Boilers BOILER CLEANING SYSTEMS for Improved Availability of Waste Incineration Boilers BOILER EFFICIENCY ENERGY RECOVERY MATERIALS HANDLING Clean Energy Solutions Range of Services for On-load Boiler Cleaning

More information

Division III Process Gas Treatment Equipment

Division III Process Gas Treatment Equipment ASME AG-1 Committee on Nuclear Air and Gas Treatment Division III Process Gas Treatment Equipment Chairman, SC Gas Process Treatment August 2008 - p 1 ASME AG-1 Division I General Requirements Division

More information

LIMESTONE HANDLING AND LIME MILLING SYSTEM

LIMESTONE HANDLING AND LIME MILLING SYSTEM LIMESTONE HANDLING AND LIME MILLING SYSTEM PURPOSE TO REDUCE THE SOx LEVEL AS PER STATUTARY REQUIREMENT TO REDUCE CORROSION EFFECT ON APH TUBES AND FLUE GAS PATH TO FEED THE LIME POWDER TO BUNKER AFTER

More information

Efficient Steam System Design

Efficient Steam System Design Efficient Steam System Design The word Efficient is often used to describe the general performance of a system. However it is important to distinguish between efficiency and effectiveness. Efficiency is

More information

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2 Modern Applied Science; Vol. 9, No. 13; 2015 ISSN 1913-1844 E-ISSN 1913-1852 Published by Canadian Center of Science and Education The Design of a Shell-Tube Heat Exchanger as Evaporator an Absorption

More information

BOILERS CHAPTER 4. Fireroom The fireroom is a compartment containing boilers and the operating station for firing the boilers.

BOILERS CHAPTER 4. Fireroom The fireroom is a compartment containing boilers and the operating station for firing the boilers. CHAPTER 4 BOILERS The function of a boiler in the steam cycle is to convert water into steam. Reliability in operating naval boilers and associated equipment is important for the power plant to operate

More information

AIM OF THE EXPERIMENT:- Study of boilers (fire tube, water tube) APPARATUS REQUIRED: - SL.NO NAME OF THE APPARATUS SPECIFICATION QUANTITY 01 Fire tube

AIM OF THE EXPERIMENT:- Study of boilers (fire tube, water tube) APPARATUS REQUIRED: - SL.NO NAME OF THE APPARATUS SPECIFICATION QUANTITY 01 Fire tube LABORATORY MANUAL ON STUDY OF FIRE TUBE AND WATER TUBE BOILERS Prepared By Prof. (Dr.) M. K. Roul Professor and Principal, Gandhi Institute for Technological Advancement (GITA), Bhubaneswar 752054 June

More information

BENSON Boilers Experience in Nearly 1000 Plants and Innovative Design Promise Continuing Success Manfred Klein, Rudolf Kral, Eberhard Wittchow

BENSON Boilers Experience in Nearly 1000 Plants and Innovative Design Promise Continuing Success Manfred Klein, Rudolf Kral, Eberhard Wittchow Products BENSON Boilers Experience in Nearly 1000 Plants and Innovative Design Promise Continuing Success Manfred Klein, Rudolf Kral, Eberhard Wittchow The unique advantages of the are its suitability

More information

Beneficial Use of Landfill Gas for Leachate Evaporation and Power Generation

Beneficial Use of Landfill Gas for Leachate Evaporation and Power Generation Beneficial Use of Landfill Gas for Leachate Evaporation and Power Generation Efficient use of Energy Turning waste to energy, liabilities to assets and visions into reality. Table of Contents BENEFICIAL

More information

Math & Physics. Complete combustion requires an Air-FuelRatio of 14.7 to 1 for combustion.

Math & Physics. Complete combustion requires an Air-FuelRatio of 14.7 to 1 for combustion. Plant OPS Math & Physics Complete combustion requires an Air-FuelRatio of 14.7 to 1 for combustion. Math & Physics Increasing oxygen levels by 9 to 15% improves boiler efficiency. Math & Physics Draft

More information

CASE STUDY ON EFFICIENCY & AVAILABILITY DETERIORATION IN AN AFBC BOILER

CASE STUDY ON EFFICIENCY & AVAILABILITY DETERIORATION IN AN AFBC BOILER CASE STUDY ON EFFICIENCY & AVAILABILITY DETERIORATION IN AN AFBC BOILER By K.K.Parthiban / Venus Energy Audit System & Sri Devi Boiler Equipment and Spares. Introduction This case study is about various

More information

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes. Introduction to Hydronics A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes. Hydronic heating systems use hot water or steam to deliver the

More information

High Performance Diesel Fueled Cabin Heater. Abstract

High Performance Diesel Fueled Cabin Heater. Abstract High Performance Diesel Fueled Cabin Heater Tom Butcher and James Wegrzyn Energy Science and Technology Division Building 526 Upton, N.Y. 11973 Brookhaven National Laboratory Abstract Recent DOE-OHVT studies

More information

ELECTRO STATIC PRECIPITATOR [ESP]

ELECTRO STATIC PRECIPITATOR [ESP] ELECTRO STATIC PRECIPITATOR [ESP] Fußzeilentext 1 Controlling Air Pollution Clean Air is an essential resource to the people surrounding the industrial belts. Air pollution is one of the major contributor

More information

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid. HEAT EXCHANGERS Heat Exchanger Heat exchanger is an apparatus or an equipment in which the process of heating or cooling occurs. The heat is transferred from one fluid being heated to another fluid being

More information

A chimney system Re-designing to increase boiler efficiency against fouling.

A chimney system Re-designing to increase boiler efficiency against fouling. A chimney system Re-designing to increase boiler efficiency against fouling. Prof. M. P. Pandagale 1, Rohit Atugade 2, Dhiraj chendkale 3, Shubham Kalshetty 4, Hitesh Adik 5, 1 Asst. Prof. Department of

More information

HOW TO BOOST THE PERFORMANCE OF FIRED HEATERS

HOW TO BOOST THE PERFORMANCE OF FIRED HEATERS Originally appeared in: November 1989 issue, pgs 239-244 CHEMICAL ENGINEERING Reprinted with publisher s permission. HOW TO BOOST THE PERFORMANCE OF FIRED HEATERS Selective revamping can hike thermal efficiency

More information

9707 Key West Avenue, Suite 100 Rockville, MD Phone: Fax:

9707 Key West Avenue, Suite 100 Rockville, MD Phone: Fax: 9707 Key West Avenue, Suite 100 Rockville, MD 20850 Phone: 301-740-1421 Fax: 301-990-9771 E-Mail: awt@awt.org Part of the recertification process is to obtain Continuing Education Units (CEUs). One way

More information

Solutions to Pollution

Solutions to Pollution Evaporator Information Solutions to Pollution Eliminate waste oils Eliminate or reduce energy costs Eliminate or reduce disposal costs Excellence in Technology, Quality & Service 1 1.0 INOV8 Evaporators

More information

Woody Biomass Fuel Drying

Woody Biomass Fuel Drying Information Sheet 12 Woody Biomass Fuel Drying Introduction Extracting useful heat energy from wood involves processing the wood in a combustor or a gasifier. Prior to combustion it can be left to dry

More information

Lecture 5 Particulate emission control by electrostatic precipitation

Lecture 5 Particulate emission control by electrostatic precipitation Lecture 5 Particulate emission control by electrostatic precipitation ELECTROSTATIC PRECIPITATORS The electrostatic precipitator is one of the most widely used collection devices for particulates. An electrostatic

More information

HEAT EXCHANGERS. Heat exchangers are broadly classified based on the following considerations.

HEAT EXCHANGERS. Heat exchangers are broadly classified based on the following considerations. HEAT EXCHANGERS INTRODUCTION The devices that are used to facilitate heat transfer between two or more fluids at different temperatures are known as heat exchangers. Different types and sizes of heat exchangers

More information

Evaporation The process in which a liquid dissipates or emits vapor, fumes, or invisible minute particles.

Evaporation The process in which a liquid dissipates or emits vapor, fumes, or invisible minute particles. 35 Evaporation of waste wash water occurs during normal operation of the pressure, steam or automatic vehicle wash system. It is generally assumed that 10-30% of wash water is lost to evaporation. Accelerated

More information

ASH MEASUREMENT AT NRG HUNTLEY USING HIGH TEMPERATURE STRAIN GAUGES

ASH MEASUREMENT AT NRG HUNTLEY USING HIGH TEMPERATURE STRAIN GAUGES Proceedings of ASME Power: ASME Power April 5-7, 2005, Chicago, Illinois PWR2005-50203 ASH MEASUREMENT AT NRG HUNTLEY USING HIGH TEMPERATURE STRAIN GAUGES Charlie Breeding/Clyde Bergemann Joe Schmitt/NRG

More information

STEAM & POWER ENGINEERS

STEAM & POWER ENGINEERS Page 1 STEAM & POWER ENGINEERS Project Site: M/s. Jamkhandi Sugars Ltd. INDIA.(Karnataka) Boiler Capacity: 90 TPH X 72.4 kg/cm2 Traveling Grate Boiler Resister Office Address: A-4/306, Rakshak Nagar Gold,

More information

2How does a vibratory fluid-bed dryer work?

2How does a vibratory fluid-bed dryer work? As appeared in April 2011 PBE Copyright CSC Publishing www.powderbulk.com Answers to five common questions about vibratory fluid-bed dryers Doug Schieber Carrier Vibrating Equipment A vibratory fluid-bed

More information

By, Mohammad Sarfaraz Khan DGM (Technical) Faran Sugar Mills Limited Shaikh Bhirkio, District Tando Mohammad Khan, Sindh.

By, Mohammad Sarfaraz Khan DGM (Technical) Faran Sugar Mills Limited Shaikh Bhirkio, District Tando Mohammad Khan, Sindh. By, Mohammad Sarfaraz Khan DGM (Technical) Faran Sugar Mills Limited Shaikh Bhirkio, District Tando Mohammad Khan, Sindh. 1. Faran Sugar Mills commissioned during 1983 with two bagasse-fired boilers of

More information

A FREAK INCIDENT OF A BED SUPERHEATER FAILURE

A FREAK INCIDENT OF A BED SUPERHEATER FAILURE A FREAK INCIDENT OF A BED SUPERHEATER FAILURE Case studies are interesting. This case is very interesting one. The customer had a bed SH failure. At the time of the visit, the failed bed SH tube was not

More information

Unit Design Data. Fossil Steam

Unit Design Data. Fossil Steam Fossil Steam Units Appendix E Unit Design Data Forms Unit Design Data Fossil Steam Instructions Use these forms to report design and installed equipment information for FOSSIL (steam) units. FOSSIL units

More information

www.greenspower.com.sg 1company profile G reens Power have been at the forefront of Waste Heat Recovery Technology since Edward Green first patented the Fuel Economiser in 1845. The business developed

More information

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas HVAC Guideline Specifications WHISPER-JET: SET SERIES Two Stage Positive Pressure Gas-Fired Infrared Radiant Tube Type Heater Commercial/Industrial Applications Technical Summary Input Range: 80,000/60,000

More information

Ontario Fire Code SECTION 5.10 COMBUSTIBLE DUST PRODUCING PROCESSES. Illustrated Commentary. Office of the Ontario Fire Marshal

Ontario Fire Code SECTION 5.10 COMBUSTIBLE DUST PRODUCING PROCESSES. Illustrated Commentary. Office of the Ontario Fire Marshal Ontario Fire Code SECTION 5.10 COMBUSTIBLE DUST PRODUCING PROCESSES Illustrated Commentary Office of the Ontario Fire Marshal Combustible Dust Illustrated Commentary 1 Mechanical Exhaust Systems 5.10.1.1.

More information

Analysis And Improving Of 10TPH Briquette Boiler Efficiency

Analysis And Improving Of 10TPH Briquette Boiler Efficiency ISSN: 78 011 (Online) Analysis And Improving Of 10TPH Briquette Boiler Efficiency B. Divya B.Tech In Mechanical Engineering P. Rajani B.Tech In Mechanical Engineering Abstract: Boiler is one of the important

More information

Hollywell kW. I ve been working with wood burners for 24 years and I've never seen a flame picture as good as this

Hollywell kW. I ve been working with wood burners for 24 years and I've never seen a flame picture as good as this Hollywell 4105 5kW I ve been working with wood burners for 24 years and I've never seen a flame picture as good as this First customer to view the product. Hollywell 4105 5kW With optional log store base.

More information

Reactor-Boiler and Auxiliaries - Course 433 BOILER STEAM AND WATER SYSTEMS

Reactor-Boiler and Auxiliaries - Course 433 BOILER STEAM AND WATER SYSTEMS Lesson 433.60-1 Reactor-Boiler and Auxiliaries - Course 433 BOILER STEAM AND WATER SYSTEMS It was noted in an earlier lesson, that the reactor is a source of heat, and serves the purpose of a "furnace"

More information

Biomass Energy Systems

Biomass Energy Systems Biomass Energy Systems Direct Fired Furnaces Dieffenbacher USA has developed direct fired biomass combustion systems for dryers, lumber dry kilns, steam boilers, and thermal oil heaters. The conservative

More information

NFPA 85 COMPLIANCES OF BMS: A CASE STUDY OF BOILER CONTROL AT SBM OFFSHORE MALAYSIA COMPANY 1. AHMED ABOUELRISH 2 Universiti Teknologi Petronas

NFPA 85 COMPLIANCES OF BMS: A CASE STUDY OF BOILER CONTROL AT SBM OFFSHORE MALAYSIA COMPANY 1. AHMED ABOUELRISH 2 Universiti Teknologi Petronas Journal of Contemporary Issues in Business Research ISSN 2305-8277 (Online), 2013, Vol. 2, No. 4, 109-123. Copyright of the Academic Journals JCIBR All rights reserved. NFPA 85 COMPLIANCES OF BMS: A CASE

More information

Variable speed hydraulic coupling and drive unit of hydraulic coupling

Variable speed hydraulic coupling and drive unit of hydraulic coupling Variable speed hydraulic coupling and drive unit of hydraulic coupling I. Model designation YO / / / Modificait on code Output speed of drive unit (r/min) Input speed of coupling or drive unit (r/min)

More information

"HC" AIRFLO. In-duct firing line burner

HC AIRFLO. In-duct firing line burner "HC" AIRFLO In-duct firing line burner -.- High heat release up to.5 MW per unit of burner length (05 mm) Clean combustion with low CO and NO x emission levels Minimal process air pressure drops locally

More information

Trade of Plumbing. Module 2: Domestic Hot and Cold Water Service Unit 10: Hot Water Supply Phase 2

Trade of Plumbing. Module 2: Domestic Hot and Cold Water Service Unit 10: Hot Water Supply Phase 2 Trade of Plumbing Module 2: Domestic Hot and Cold Water Service Unit 10: Hot Water Supply Phase 2 Table of Contents List of Figures... 4 List of Tables... 5 Document Release History... 6 Module 2 Domestic

More information

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad- 500 043 B.Tech (III II SEM) MECHANICAL ENGINEERING REFRIGERATION AND AIR CONDITIONING Prepared by, Dr. CH V K N S N Moorthy, Professor

More information

Efficiency and Design Improvements in Multiple Hearth & Fluid Bed Incinerators

Efficiency and Design Improvements in Multiple Hearth & Fluid Bed Incinerators Efficiency and Design Improvements in Multiple Hearth & Fluid Bed Incinerators CBE Chavond-Barry Engineering 400 Rt. 518, Blawenburg, NJ 08504 Outline Fluid Bed Incinerators (FBI s) - Reversible Bed Resizing

More information

Removing the moisture contents of coal using solar drying

Removing the moisture contents of coal using solar drying Case Study 2 Removing the moisture contents of coal using solar drying Implementing the technology A wall and floor tiles industry uses spray dryers for the formation of granules. The hot gases to the

More information

Design of Air Pre-Heater for Blast Furnace Gas Fired Boiler

Design of Air Pre-Heater for Blast Furnace Gas Fired Boiler Design of Air Pre-Heater for Blast Furnace Gas Fired Boiler R.Venkateshkumar, Kishor Kumar, B.Prakash, R.Rahul Department of Mechanical Engineering, M.Kumarasamy College of Engineering, Thalavapalayam,

More information

Document Code: 1 (13) Issuing date: Status:

Document Code: 1 (13) Issuing date: Status: Document Code: 1 (13) Project : MULTI FUEL CFB BOILER SIMULATOR Author: Approved: Language: JJA Document title: SYSTEM DESCRIPTION REHEAT STEAM SYSTEM Submitted for: Customer reference: Other information:

More information

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

POWER VENTER SYSTEM. Model: PVO-300, PVO-600 POWER VENTER SYSTEM Model: PVO-300, PVO-600 Included is one ETL and cetl listed Power Venter to be used primarily with a single 120VAC controlled oil fired furnace, boiler, or water heater. The PVO may

More information

Typical damages to Boilers & Economizers

Typical damages to Boilers & Economizers Typical damages to Boilers & Economizers A guide how to discover and prevent. Most commonly seen damages Boiler water side - Damages caused by : Contamination with oil Scales and Sludge Oxygen Corrosion

More information

BASIC BOILERS NAME :- DATE :-

BASIC BOILERS NAME :- DATE :- BASIC BOILERS NAME :- DATE :- This examination was conducted under conditions that allowed a fair and honest test of the candidate s knowledge and ability. Exam supervisor C:\Tassie Steam\N01basicboiler

More information