NON-PROGRAMMABLE THERMOSTAT «ETN»

Size: px
Start display at page:

Download "NON-PROGRAMMABLE THERMOSTAT «ETN»"

Transcription

1 N-PROGRAMMABLE THERMOSTAT «ETN» Installation instructions Electrical Handling and Connecting 9 Cool Auto Fan o C Order no.: AM October-05. Replacing order no.: New The manufacturer reserves the right to make any modifications without prior notice. Code XK01J010N

2 Please read this manual carefully before installaton and use 1.- General features and Accessories..- Installation instructions. 3.- Sizes. 4.- Electrical conections. Temperature range Marking Inflammability Inlet temperature Weight 1.- General Features from 10 ºC to 35 ºC CE UL94V-0 Sonda 50 K a 5 ºC 0.15 Kg CTENTS 5.- Micro switches. 6.- Operating manual. 7.- Technical Adjustments. 8.- Wiring Diagrams. 1.- Accesories (*) Remote NTC atmospheric probe 50 K NTC duct probe 50 K (*).- See availability ALARMS: INTERCNECTI BETWEEN THE THERMOSTAT AND THE UNITS WITH MASTER LINK-I LY VALID FOR WIRING DIAGRAMS: REF.-ETN AND 16 FREE VOLTAGE CTACT UNITS FREE VOLTAGE CTACT UNITS AND ELECTRICAL HEATERS B B1 B4 K1 K B3 K3 K4 B K5 K6 B1 PA1/PA B B1 B4 K1 K B3 K3 K4 B K5 K6 B1 PA1/PA.- Installation instructions E E THERMOSTAT TERMINALS E E THERMOSTAT TERMINALS A.- Separe the front panel from the rear by pressing down on the tab on top of the thermostat

3 ALARMS: INTERCNECTI BETWEEN THE THERMOSTAT AND THE UNITS WITH MASTER LINK-I LY VALID FOR WIRING DIAGRAMS: REF.-ETN AND 16 UNITS WITHOUT ELECTRICAL HEATERS UNITS WITH ELECTRICAL HEATERS B.- Remove rear panel. B B1 B4 K1 K B3 K3 K4 B K5 K6 B1 PA1/PA B B1 B4 K1 K B3 K3 K4 B K5 K6 B1 PA1/PA 73 (*) C.- Pass the connection wiring through the hole marked with 1. Secure the rear panel to a standard recessed box using the two screws marked with or to wall or flat surface using the three screws marked with 3. Make the electrical connections as shown in the attached wiring diagrams. E E THERMOSTAT TERMINALS PA1 / PA Expansion Board required for interconnection THERMOSTAT E E TERMINALS Disconnect wiring 73 from terminal and connect this end to one of terminal E on the thermostat terminal strip. If this connection is made, the bridge marked with must be made (*). The other thermostat terminal E is connected from the K5 on the board or from terminal 70. D.- Mount from thermostat panel on rear, firt using the two tabs at the bottom and then pushing until the top tab fits into the rear part secured to the wall

4 3.- Dimensions ( mm.) Front Panel 9 Cool Heat Auto Fan 9 S E T AUX On / Off Mode Fan 80 N-PROGRAMMABLE THERMOSTAT MODELS «50RHE » Y1 G Y S S W E E W 1 O C R Y G AL1 AL W O C R (Heat pump Models) MICROS BLOCK S REF.- ETN

5 N-PROGRAMMABLE THERMOSTAT MODELS «38UQZ + 40ALZ » Y 1 G Y S S W E E W 1 O C R Dimensions ( mm.) Rear Panel Spacing for connection wiring. Holes for screwing the Thermostat to a standard recessed box. Y 1 G W O C R (Heat pump Models) MICROS BLOCK S REF.- ETN Grooves 5.5 x 3.5 Groove 6.5 x Holes o Connection terminals 3 Grooves for screwing the Thermostat to a wall or flat surface.

6 4.- Electrical connections Indication of the meaning of the thermostat connections. TERMINAL BLOCKS FUNCTI R C E E O W1 W S S Y G Y1 4 Vac 0 Vac Alarm (inlet for NA power-free contact Alarm (inlet for NA power-free contact) Reversible valve Electrical heater Electrical heater Atmospheric sensor or remote return Atmospheric sensor or remote return Compressor (Cold / Heat) Ventilation Compressor 1 (Cold / Heat) IMPORTANT! Before making any modification to the Micro-switches, disconnect any power to the air conditioning unit N-PROGRAMMABLE THERMOSTAT MODELS «38XTZ + 40ABZ » Y 1 G Y S S W E E W 1 O C R Y 1 G Y C R (Cooling only Models) MICROS BLOCK S (*) (*).- Set Micro no 5 on Block S to when the Unit starts up the Hot Water Coil. REF.- ETN

7 N-PROGRAMMABLE THERMOSTAT MODELS «38XTZ + 40ALZ 014» 5.- Micro-switches Location of micro-switch blocks S1 - S. Y 1 G Y S S W E E W 1 O C R (Cooling only Models) MICROS BLOCK S (*) (*).- Set Micro nº 5 on Block S to when the Unit starts up the Hot Water Coil. S S Micro-switch position Each block has 6 micro-switches. Each micro-switch can be set to or. Example micros 1 and 6 to and micros, 3, 4 and 5 to REF.- ETN Micro-switches Blocks «S1» and «S» DIP

8 5. Configuring the Micro-switches of micro-switches on Block S1: Micro n o must be set to Micros n o must be set to Note: Micro sets Heat and Aux. mode. Heat on screen and the possibility of user selection. of micro-switches on Block S: PROBE TYPE internal remote (Atmospheric or return) UNIT TYPE Heat Pump Cold + Electrical Heater Cold + Hot water Coil -SCREEN DISAY Set Temp. Atmospheric or return temp. MICRO POSITI MICRO POSITI 4 5 MICRO POSITI 6 N-PROGRAMMABLE THERMOSTAT MODELS «38XTZ + 40ALZ 011» Y 1 G Y S S W E E W 1 O C R Y 1 G W 1 C R (Cooling only Models) MICROS BLOCK S (*) (*).- Set Micro no 5 on Block S to when the Unit starts up the Hot Water Coil. REF.- ETN

9 N-PROGRAMMABLE THERMOSTAT MODELS «50PZ / 38PZ + 40PZ » Y 1 G Y S S W E E W 1 O C R IMPORTANT: To check if the Unit has a jumper befween «R & 16» or «R & 17». If yes, this jumper must be removed before doing new thermostat connections. The micro-switches are factory configured by default in the following position: 5.3 Atmospheric or remote return sensor connection (optional) NTC Sensor: Temperature~Resistance Features Temp ºC Resist. k BLOCK S1 1, 3, 4, 5, BLOCK S 1, 3, 6, 4, Y 1 G Y W 1 O C R (Heat pump Models) Factory configuration includes an internal sensor. Disconnect the 4 vac power supply to the thermostat. Set micro-switches 1,, 3 on block S as required. Connect the temperature sensor to terminals S and S. Reconnect the 4 vac. power supply. MICROS BLOCK S Use shielded-type wiring to connect the sensor. REF.- ETN

10 N-PROGRAMMABLE THERMOSTAT MODELS «50PZ / 38PZ + 40PZ » «50YZ / 38BZ + 40BZ » OPERATING MANUAL AND TECHNICAL ADJUSTMENT Y 1 G Y S S W E E W 1 O C R Y 1 G W 1 O C R (Heat pump Models) IMPORTANT: To check if the Unit has a jumper befween «R & 16» or «R & 17». If yes, this jumper must be removed before doing new thermostat connections MICROS BLOCK S REF.- ETN

11 N-PROGRAMMABLE THERMOSTAT MODELS «50VZ / 38VZ + 40PZ » 9 Cool O F F 6. Thermostat Screens This screen will appear once all the necessary electrical connections have been made between the thermostat and the Unit. Y 1 G Y S S W E E W 1 O C R IMPORTANT: To check if the Unit has a jumper befween «R & 16» or «R & 17». If yes, this jumper must be removed before doing new thermostat connections. AutoFan 9 Coll O N 6.1 / Press the On/Off button to switch the thermostat on. This screen will appear. To turn the thermostat off, press the On/Off button again. Y 1 G Y W W 1 C R (Cooling only Models) MICROS BLOCK S (*) (*).- Set Micro no 5 on Block S to when the Unit starts up the Hot Water Coil. Auto Fan 3 Cool Auo Fan REF.- ETN O N 6. Temperature adjustment Press (+) or (-) to set the temperature. This will flash for 3 seconds and the atmospheric or set temperature will then appear, according to the position of micro-switch 6 on block S.

12 3 Heat O N Auto Fan On / Off M o d e F a n 3 O N Heat Aux Auto Fan On / Off M o d e F a n 6.3 Unit operating mode selection Press the Mode button to choose the operating mode: 1.- When pressed once, Heat will appear on screen (Heat Mode).- When pressed twice, Cool / Heat will appear on screen (Auto Mode) 3.- When pressed 3 times, Fan will appear on screen (Fan Mode) 4.- When pressed 4 times, Cool will appear on screen (Cool Mode) The operating mode will flash on the thermostat screen. While the thermostat is timed, the operating mode will be permanently displayed Emergency heating, can only be selected on Heat pump units. This is enabled by pressing the Mode button for 5 seconds. To cancel emergency heating and return to heat pump mode, press the Mode button for 5 seconds. N-PROGRAMMABLE THERMOSTAT MODELS «50VZ / 38VZ + 40PZ » «50TZ / 38FZ + 40BZ / TZ » Y 1 G Y S S W E E W 1 O C R Y 1 G W 1 C R IMPORTANT: To check if the Unit has a jumper befween «R & 16» or «R & 17». If yes, this jumper must be removed before doing new thermostat connections. 3 Cool O N Fan 6.4 Fan/Auto Fan operating. Press the Fan button to change the Fan/Auto Fan operating mode. In Auto Fan mode the fan will only operate when there is a demand for heat or cold, i.e. when the unit compressors and fans are working (Cooling only Models) MICROS BLOCK S (*) (*).- Set Micro no 5 on Block S to when the Unit starts up the Hot Water Coil. REF.- ETN

13 N-PROGRAMMABLE THERMOSTAT MODELS «50HZ » WITH FREE COOLING Temperature and probe reading adjustments. Press the On/Off button for 7 seconds and 50 will appear on screen. Press the (+) button until 55 appears. Y 1 G Y S S W E E W 1 O C R K K 1 K (*) (*) (*) 8 3 Y 1 G 8 Y 7 O C R (Heat pump Models) MICROS BLOCK S LEGEND K.- Two-contact 4V. relay. (To be installed). K1 / K.- Relay contacts. ( * ).- Relay connection. REF.- ETN S E T Cool 6 S E T Heat 7.1 Temperature limit for cold operations. Press the On/Off button again and Cool and Set will appear. Press (+) or (-) to adjust the set limit required. The temperature range is from 10 ºC to 30 ºC Recommended 19 ºC. (By default 10 ºC). 7. Temperature limit for heat operations. Press the On/Off button again and Heat and Set will appear. Press (+) or (-) to adjust the set limit required. The temperature range is from 10 ºC to 30 ºC Recommended 6 ºC. (By default 30 ºC). IIMPORTANT Users can change the settings on the thermostat screen without taking the temperature limits into account, although the thermostat will work according to the settings established (Sections 7.1 and 7.)

14 0 S E T UL On / Off M o d e F a n LC On / Off M o d e F a n 7.3 Calibrating the probe reading. Press the On/Off button again. SET will appear on screen. Adjust the probe reading value using buttons (+) and (-). The calibration range is from -6 ºC to 6 ºC Value by default 0 ºC. 7.4 Locking the thermostat buttons. Press the On/Off button for 7 seconds and 50 will appear on screen. Press the (-) button until 45 appears. Press the On/Off button and UL will appear on screen (unlocked). Then press the (+) button and Lc (locked) will appear on screen. 7.5 Unlocking the thermostat buttons. Press the On/Off button for 7 seconds and 50 will appear on screen. Press the (-) button until 45 appears. Press the On/Off button and Lc will appear on screen (locked). The press the (-) button and UL (unlocked) will appear on screen. N-PROGRAMMABLE THERMOSTAT MODELS «50HZ 016» WITH FREE-COOLING Y 1 G Y S S W E E W 1 O C R 83 G 8 O 7 W 1 C R This Unit can exceptionally be configured as Cooling only, despite it including a Heat Pump (Heat pump Models) MICROS BLOCK S REF.- ETN

15 N-PROGRAMMABLE THERMOSTAT MODELS «50HZ » WITHOUT FREE-COOLING Y 1 G Y S S W E E W 1 O C R Y 1 G Y 7 O C R (Heat pump Models) MICROS BLOCK S - - REF.- ETN S E T FI O N EC S E T O N 7.6 Filter alarm adjustment. Press the On/Off button for 7 seconds. 50 will appear on screen. Press the (+) button until 80 appears, then press the On/Off button. The number of hours that the Unit has been running since the last reset made will appear on screen. Press the (+) or (-) buttons to adjust the filter change alarm. (Range: 0, 100, 00,..., 900 hours). This is 400 hours by default. The adjustment displays the number of hours divided by 10 (e.g. «40» are 400 hours). If the value 0 is set, the filter alarm option is cancelled. When the thermostat reaches the time indicated, the screen will flash, showing the atmospheric temperature and «FI» alternatively. To cancel the alarm, keep the Fan button pressed down for 15 seconds. 7.7 «EC» alarm signal. The bushing marked with the letter «E» are for free voltage contact (normally open). When an alarm is triggered, the thermostat screen will show the atmospheric temperature and «EC» alternatively. Once the problem on the Unit has been solved, the thermostate will automatically return to its operating mode. No alarm is displayed when the thermostate is switched

16 N-PROGRAMMABLE THERMOSTAT MODELS «50HZ 016» WITHOUT FREE-COOLING Y 1 G Y S S W E E W 1 O C R CNECTI DIAGRAMS BETWEEN THE THERMOSTAT AND THE UNIT Y 1 G O 7 W 1 C R This Unit can exceptionally be configured as Cooling only, despite it including a Heat Pump (Heat pump Models) MICROS BLOCK S REF.- ETN

17 N-PROGRAMMABLE THERMOSTAT MODELS «50GZ » WITH FREE-COOLING N-PROGRAMMABLE THERMOSTAT MODELS «50GZ 016» WITHOUT FREE-COOLING Y 1 G Y S S W E E W 1 O C R Y 1 G Y S S W E E W 1 O C R 83 G C R (Cooling only Models) MICROS BLOCK S (*) (*).- Set Micro no 5 on Block S to when the Unit starts up the Hot Water Coil. Y 1 G 71 7 C R (Cooling only Models) REF.- ETN MICROS BLOCK S (*) (*).- Set Micro no 5 on Block S to when the Unit starts up the Hot Water Coil. REF.- ETN

18 N-PROGRAMMABLE THERMOSTAT MODELS «50GZ » WITHOUT FREE-COOLING N-PROGRAMMABLE THERMOSTAT MODELS «50GZ 016» WITH FREE-COOLING Y 1 G Y S S W E E W 1 O C R Y 1 G Y S S W E E W 1 O C R Y 1 G Y 71 7 C R (Cooling only Models) MICROS BLOCK S (*) (*).- Set Micro no 5 on Block S to when the Unit starts up the Hot Water Coil. REF.- ETN G C R (Cooling only Models) MICROS BLOCK S (*) (*).- Set Micro no 5 on Block S to when the Unit starts up the Hot Water Coil. REF.- ETN

ETN-24-SUPER-SF Series

ETN-24-SUPER-SF Series Meitav-tec Ltd (Contel group) Tel: +972 (3) 962 6462 Fax: +972 (3) 962 6620 www.meitavtec.com - support@meitavtec.com ETN-24-SUPER-SF Series Owner s Manual Installation and Operating Instructions Please

More information

Please read this manual carefully before installation and use.

Please read this manual carefully before installation and use. Doylestown, PA 18902 USA Phone: 215-766 1487 - Fax: 215-766 1493 Email: support@scillc.com - www.scillc.com FMT-24-SUPER-PROG With freeze protection Owner s Manual Installation and Operating Instructions

More information

ETN24-P/PD-FC-SUPER2. Owner's Manual - Installation and Operating Instructions

ETN24-P/PD-FC-SUPER2. Owner's Manual - Installation and Operating Instructions ETN24-P/PD-FC-SUPER2 Owner's Manual - Installation and Operating Instructions Rev. 1 04.08 itav-tec Ltd (Contel group) Tel: +972-3-9626462 Fax: +972-3-9626620 www.meitavtec.com - support@meitavtec.com

More information

ETN-24-SUPER-PROG (US Program - Celsius)

ETN-24-SUPER-PROG (US Program - Celsius) Meitavtec Ltd (Contel group) Tel: 972 (3) 962 6462 Fax: 972 (3) 962 6620 www.meitavtec.com support@meitavtec.com ETN24SUPERPROG (US Program Celsius) Owner s Manual Installation and Operating Instructions

More information

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control O M N I S T A T ELECTRONIC COMMUNICATING THERMOSTAT Installation Manual RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control Document Number 13I00-5 November, 1997 CONTENTS

More information

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings ETNC-FC-BAC-PIR- Rev. Index Operating instructions....- Turning the thermostat and OFF Selecting temperature scale Adjusting the Set point temperature (for set point and set points configurations) Selecting

More information

ELECTRONIC COMMUNICATING THERMOSTAT

ELECTRONIC COMMUNICATING THERMOSTAT O M N I S T A T ELECTRONIC COMMUNICATING THERMOSTAT Installation Manual RC-81 Single Stage Heat/Cool Real Time Pricing System Document Number 13I00-2 January, 1997 Copyright 1997 Home Automation, Inc.

More information

THERMOSTAT i-basic 3 USER MANUAL Rev.100

THERMOSTAT i-basic 3 USER MANUAL Rev.100 USER MANUAL Thank you for trusting the Hitecsa Products. Our company has been offering the market an extended range of specialized units for air conditioning and cooling installations for over 35 years.

More information

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page. INSTALLATION MANUAL This manual covers the following models: T915 Thermostat Applications Guide Des cription Gas or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency Heat) Heat Pump (with Aux.

More information

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool O M N I S T A T ELECTRONIC COMMUNICATING THERMOSTAT Installation Manual RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool Document Number 13I00-4 January, 1997 Copyright 1997 Home Automation,

More information

DPC-1 Programmable digital thermostat with communication Versión 2.0. Technical Information. Ref: N

DPC-1 Programmable digital thermostat with communication Versión 2.0. Technical Information. Ref: N DPC-1 Programmable digital thermostat with communication Versión 2.0 Ref: N-27360 1108 Technical Information I S O 9 0 0 1 ER-0028/1991 Johnson Controls Manufacturing España, S.L. is participating in the

More information

CEM-24 Series. Owner's Manual - Installation and Operating Instructions

CEM-24 Series. Owner's Manual - Installation and Operating Instructions CEM-24 Series Owner's Manual - Installation and Operating Instructions Rev. 6.4 01.10 Pipersville, PA 18947 USA Phone: (215) 766-1487 - Fax: (215) 766-1493 Email: support@scillc.com - www.scillc.com Please

More information

INSTALLATION & USER MANUAL

INSTALLATION & USER MANUAL INSTALLATION & USER MANUAL HC Digital Automatic Humidistat (Y3760) CONTROLS 506808-01 3/2016 Supersedes 6/2011 picture goes here THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE NOTICE

More information

T-32-TS Touchscreen Thermostat. Installation Manual

T-32-TS Touchscreen Thermostat. Installation Manual T-32-TS Touchscreen Thermostat Installation Manual TABLE OF CONTENTS Introduction...4 Getting Started...5 Installing the Thermostat...6, 8 Disassembly...6 Thermostat Location...6 Mounting the Subbase...6,

More information

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422 ºF / º C Rooftop Thermostat Controller Model TRT2422 Description The TRT2422 is a combination controller and thermostat with a built-in scheduler, which is designed for simple and accurate control of single

More information

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page.

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page. INSTALLATION MANUAL This manual covers TopTech models: TT-N-851 Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency Heat) Heat Pump (with Aux. or

More information

ERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135

ERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135 ERV-24 Technician Settings & Operating Manual Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135 1 Introduction brief description General The ERV-24-HC11

More information

Table 1. Serie of Digital Room Thermostats.

Table 1. Serie of Digital Room Thermostats. Digital Room Thermostats INSTALLATION MANUAL APPLICATION DR is a serie of Digital Room Thermostats, provides a single stage, temperature control. Table 1 shows all the available models. All models can

More information

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL 1. INTROUCTION Zone control is a two pieces fan coil thermostat available for Heat/Cool versions. Its application is for the duct type system

More information

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help? INSTALLATION MANUAL This manual covers the following models: T955W Master Thermostat Base Module Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency

More information

ETN1000/MIGA - Operating manual

ETN1000/MIGA - Operating manual o C ETN1000/MIGA - Operating manual Cool Heat Fan Hi Med Lo SET ON OFF AUX Auto Fan 1. Switching the unit ON/OFF On/Off Mode Fan Press the ON/OFF button to activate or deactivate the thermostat - ON or

More information

JDDT1 - Single Stage Digital Thermostat

JDDT1 - Single Stage Digital Thermostat JDDT1 - Single Stage Digital Thermostat CAUTION NOTICE: The thermostat must be installed by authorized professionals. It should be located in a place free of vibrations, impacts, and corrosive gases. SET

More information

CERTIFIED PERFORMANCE

CERTIFIED PERFORMANCE Compact Horizontal Air-Air Heat Pump Model RTH-7 to B/G Ref.: TRTHBBE Technical information ACCORDING TO ISO 9 STANDARDS ER-//9 ACCORDING TO ISO STANDARDS CGM-97/ EUROVENT CERTIFIED PERFORMANCE Clima Roca

More information

Installation Instructions Read and become familiar with these instructions before beginning installation.

Installation Instructions Read and become familiar with these instructions before beginning installation. KSAIC005 (5V) KSAIC00230 (208-230V) 24V Interface Kit for Ductless Systems Installation Instructions Read and become familiar with these instructions before beginning installation. SAFETY CSIDERATIS Read

More information

Touch Screen Thermostat. MTSC/SUPER, MTSC24/SUPER Series. MTS/SUPER, MTS24/SUPER Series. Owner s manual and technician settings

Touch Screen Thermostat. MTSC/SUPER, MTSC24/SUPER Series. MTS/SUPER, MTS24/SUPER Series. Owner s manual and technician settings Touch Screen Thermostat MTSC/SUPER, MTSC24/SUPER Series MTS/SUPER, MTS24/SUPER Series Owner s manual and technician settings -2 - Index 1. Owner s Manual... 4 1.1 Quick Guide. 4 1.2 Turning the unit ON

More information

FMT24-SUPER-2S-FP-PROG-F Owner s manual & Technician Settings. Installation

FMT24-SUPER-2S-FP-PROG-F Owner s manual & Technician Settings. Installation Installation The FMT24-SUPER-2S-FP-PROG is designed for flush mounting in the room to be controlled. It should be located where the occupant can easily read the LCD display and use the controls. If the

More information

Smart Temp. ApolloP/n Installation Manual. Version 1.0

Smart Temp. ApolloP/n Installation Manual. Version 1.0 Smart Temp ApolloP/n 44-800 Installation Manual Version 1.0 TABLE OF CONTENTS Introduction...6 Getting started...7 Installing the thermostat...8 Disassembly...8 Thermostat location...8 Mounting the subbase...8,

More information

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power. Technical Information Electric Slide-In Range JES8850ACB/S/W JES9750ACB/W JES9800ACB/S/W JES9860ACB/S/W Due to possibility of personal injury or property damage, always contact an authorized technician

More information

Installation and Advanced Programming Instructions. HP8211-1RJ and HP8321-1RJ Heat Pump Thermostats

Installation and Advanced Programming Instructions. HP8211-1RJ and HP8321-1RJ Heat Pump Thermostats Installation and Advanced Programming Instructions HP8211-1RJ and HP8321-1RJ Heat Pump Thermostats These instructions are intended for installation and first time set up of the thermostat. For day to day

More information

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions DESCRIPTION The RC-90 is a precision digital thermostat designed for 24 VAC single stage heating and

More information

Touch Screen Thermostat. MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series. MTS/SUPER/CO2, MTS24/SUPER/CO2 Series. Owner s manual and technician settings

Touch Screen Thermostat. MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series. MTS/SUPER/CO2, MTS24/SUPER/CO2 Series. Owner s manual and technician settings Touch Screen Thermostat MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series MTS/SUPER/CO2, MTS24/SUPER/CO2 Series Owner s manual and technician settings Rev. 2.4 Index 1. Owner s Manual... 3 1.1 Quick Guide. 4 1.2

More information

RC-122BZ Two Stage Heat/Cool 2 Stage Heat / 2 Stage Cool Thermostat Installation Instructions

RC-122BZ Two Stage Heat/Cool 2 Stage Heat / 2 Stage Cool Thermostat Installation Instructions RC-122BZ Two Stage Heat/Cool 2 Stage Heat / 2 Stage Cool Thermostat Installation Instructions DESCRIPTION The RC-122BZ is a precision digital thermostat designed for 24 VAC two-stage heating and cooling

More information

USER'S OPERATING INSTRUCTIONS

USER'S OPERATING INSTRUCTIONS SAT-2 Thermostat COOL FAN DRY HEAT AUTO SLEEP SWING AUTO ZONE SUN MON TUE WED THU FRI SAT HEATER ON OFF ERR UNIT USER'S OPERATING INSTRUCTIONS CONTENTS Page Introduction 3 Features Summary 3 Display 4

More information

Indicates incorrect room temperature. No second stage or AUX heating. Emergency heat does not turn on

Indicates incorrect room temperature. No second stage or AUX heating. Emergency heat does not turn on Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please

More information

Comfort System T-21-P Touchscreen Thermostat Installation Manual

Comfort System T-21-P Touchscreen Thermostat Installation Manual Comfort System T-21-P Touchscreen Thermostat Installation Manual Version 1.40 INTRODUCTION The Comfort System T-21-P is a feature-rich touchscreen thermostat that can be battery powered or hardwired to

More information

ETN-24-HC21-PROG Econo-Vent

ETN-24-HC21-PROG Econo-Vent ETN-24-HC21-PROG Econo-Vent Owner's Manual - Installation and Operating Instructions Cat. G030121 Rev. 3.1 02.06 Meitav-tec Ltd (Contel group) Tel: 972-3-9626462 ax: 972-3-9626620 www.meitavtec.com - support@meitavtec.com

More information

ONX908MTW-0/24V MULTI STAGE THERMOSTAT

ONX908MTW-0/24V MULTI STAGE THERMOSTAT ONX908MTW-0/24V MULTI STAGE THERMOSTAT Application: 24VAC,2Heat/2cool Installation and operation instructions SPECIFICATION: Electrical Rating 24VAC Terminal Load 3.0 A per terminal (terminal Y1, W1, G:

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 50A55-474 & 50A55-571 Integrated Furnace Controls INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE

More information

OWNER S MANUAL Venstar Inc. 08/07

OWNER S MANUAL Venstar Inc. 08/07 Digital Thermostat residential THERMOSTAT T1 900 7-DAY MABLE up to 3-heat & 2-cool HEAT COOL HEAT PUMP with HUMIDITY CONTROL Control up to 3 Heat & 2 Cool Stages 3 Configurable Outputs Adjustable 2nd &

More information

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16 TraceTek TTSIM-1A TraceTek Sensor Interface Module with Relay Installation/OPERATION Instructions Approvals and Certifications TYPE NM General Signaling Equipment 76LJ Only AC versions are UL listed and

More information

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page.

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page. INSTALLATION MANUAL This manual covers the following models: T725 Thermostat Applications Guide Des cription Gas or Oil Heat Electric Furnace Heat Pump ( Aux. or Emergency Heat) Heat Pump (with Aux. or

More information

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page. INSTALLATION MANUAL This manual covers the following models: T755 Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency Heat) Heat Pump (with Aux. or

More information

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification Dual Technology Wall Switch Occupancy Sensor Manual & Specification PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES Douglas Lighting Controls Page 1 November 19, 2014 1. INTRODUCTION

More information

IntelliSync Thermostat / Mobile App Frequently Asked Questions

IntelliSync Thermostat / Mobile App Frequently Asked Questions IntelliSync Thermostat / Mobile App Frequently Asked Questions This FAQ page addresses the most common questions on Deriva IntelliSync. Why bother setting a heating and cooling schedule? What is ENERGY

More information

HEAT HEAT HEAT COOL COOL

HEAT HEAT HEAT COOL COOL OWNER S MANUAL AUTO 74 COOL 7 2 HEAT T O T A L I N E HEAT COOL COMMERCIAL THERMOSTAT P/N P374-2700 HEAT PUMP NON-PROGRAMMABLE DIGITAL THERMOSTAT 3 Configurable Outputs Control up to 2 Heat & 2 Cool Stages

More information

Installation Instructions Read and become familiar with these instructions before beginning installation.

Installation Instructions Read and become familiar with these instructions before beginning installation. KSAIC020230 (208-230V) 24V Interface Kit for Ductless Outdoor Single Zone matched with Air Handler Installation Instructions Read and become familiar with these instructions before beginning installation.

More information

OPERATION MANUAL. ComfortSense 3000 Series Model No. L3011C Non-Programmable Thermostat. Table of Contents. L3011C Thermostat

OPERATION MANUAL. ComfortSense 3000 Series Model No. L3011C Non-Programmable Thermostat. Table of Contents. L3011C Thermostat 2008 Lennox Industries Inc. Dallas, Texas, USA OPERATION MANUAL ComfortSense 3000 Series Model No. L3011C Non-Programmable Thermostat RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE L3011C Thermostat The

More information

E U R O V E N T CERTIFIED PERFORMANCE

E U R O V E N T CERTIFIED PERFORMANCE Compact Horizontal Air-Air Heat Pump Model RTH-7K to 3K Ref.: Y-R719 7 Technical information E U R O V E N T CERTIFIED PERFORMANCE I S O 9 1 ER-8/1991 Clima Roca York S.L. is participating in the EUROVENT

More information

OPERATION MANUAL. ComfortSense 3000 Series Model No. L3021H Non Programmable Thermostat. Table of Contents. Description. Initial Thermostat Power up

OPERATION MANUAL. ComfortSense 3000 Series Model No. L3021H Non Programmable Thermostat. Table of Contents. Description. Initial Thermostat Power up 2018 Lennox Industries Inc. Dallas, Texas, USA OPERATION MANUAL ComfortSense 3000 Series Model No. L3021H Non Programmable Thermostat CONTROLS 506078-02 9/2018 Supersedes 5/2017 THIS MANUAL MUST BE LEFT

More information

T7200D,E Series 2000 Commercial Microelectronic Thermostats

T7200D,E Series 2000 Commercial Microelectronic Thermostats T7200D,E Series 2000 Commercial Microelectronic Thermostats INSTALLATION INSTRUCTIONS APPLICATION The T7200D,E Thermostats provide electronic control of 24 Vac commercial single-zone heating, ventilating

More information

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

ELECTRIC POSITION for electric heat, then confirm with Fan Test below. Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please

More information

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS GENERAL INFORMATION Please read these instructions and keep them in a safe place. These instructions must

More information

OWNER S MANUAL Venstar Inc. 08/07

OWNER S MANUAL Venstar Inc. 08/07 Digital Thermostat residential THERMOSTAT T1 800 7-DAY PROGRAMMABLE up to 3-heat & 2-cool HEAT COOL HEAT PUMP Control up to 3 Heat & 2 Cool Stages 3 Configurable Outputs Adjustable 2nd & 3rd Stage Timers

More information

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide.

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide. INSTALLATION MANUAL This manual covers TopTech models: TT-N-721 and T721 Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump ( Aux. or Emergency Heat) Heat Pump (with Aux.

More information

Auto-Changeover: Cool Setpoint: Deadband: Dehumidify: Differential: Heat Setpoint: Humidify: Icon: Mode: Non-Programmable Thermostat:

Auto-Changeover: Cool Setpoint: Deadband: Dehumidify: Differential: Heat Setpoint: Humidify: Icon: Mode: Non-Programmable Thermostat: SM CAUTION Follow the Installation Instructions before proceeding. Set the thermostat mode to OFF prior to changing settings in setup or restoring Factory Defaults. This Explorer thermostat has the ability

More information

Fan Coil Thermostat. Specification & Installation Instructions TFC54F3Y1. Technical Data

Fan Coil Thermostat. Specification & Installation Instructions TFC54F3Y1. Technical Data Fan Coil Thermostat Features: Selectable pipe or 4 pipe system Selectable control mode Selectable fan speed contact Selectable Fahrenheit or Celsius scale Manual Night Set Back override (programmable)

More information

Safety & Installation Instructions

Safety & Installation Instructions Model 8476 Thermostat with Event-Based Air Cleaning Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS Table of contents Installation Installation location recommendations... 3 Outdoor

More information

Technicians Manual Single Compressor

Technicians Manual Single Compressor Technicians Manual Single Compressor HAC-FF-D WALL PAD Operating Manual Version PCB Version V2.3.5 Version wall pad Version Manual Page 1 Contents 1. Main features 2. Main technical data 3. Wall pad 4.

More information

PARAGON Commercial Refrigeration Controls

PARAGON Commercial Refrigeration Controls PARAGON Commercial Refrigeration Controls ERC 2 Electronic Refrigeration Control The ERC 2 Electronic Refrigeration Control is a microprocessor-based electronic controller designed to control both the

More information

Cat. No TPT44. Installation & Operating Instructions

Cat. No TPT44. Installation & Operating Instructions Underfloor Heating Controller Cat. No TPT44 Installation & Operating Instructions 1 General The ProgramaSTAT TPT44 combines the elements of timeswitch and room thermostat in a single compact, economical

More information

Safety & Installation Instructions

Safety & Installation Instructions 8400 Series Thermostats Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS 61000652C 8400 Tstat Install.indd 1 10/13/09 11:08:56 AM Table of contents Installation Installation location

More information

HEAT COOL. Meets Commercial California Title 24

HEAT COOL. Meets Commercial California Title 24 Digital Thermostat commercial THERMOSTAT T2900 7-DAY MABLE up to 3-heat & 2-cool HEAT COOL HEAT PUMP Control up to 3 Heat & 2 Cool Stages 3 Configurable Outputs Adjustable 2nd & 3rd Stage Timers & Deadbands

More information

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55 96239823 SWITCHLITE MRE SLD MAN 96239821 SWITCHLITE MRE SLD IP55 Overview The SWITCHLITE MRE SLD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

Networkable Fan Coil Controller Specification and Installation Instructions

Networkable Fan Coil Controller Specification and Installation Instructions Controller Models EFCB10T-OE1 (24Vac / 0 relays) EFCB12T-OE1 (240Vac / 0 relays) EFCB10TU4-OE1 (24Vac / 4 relays) EFCB12TU2-OE1 (240Vac / 2 relays) EFCB12TU4-OE1 (240Vac / 4 relays) TFL Series Thermostat

More information

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction. Introduction The UL listed Phone-A-Stat (model # 7632 ) is designed and approved for the safe operation of remotely controlling four independent loads, such as a sprinkler system or a water heater via

More information

HEAT PUMP PROGRAMMABLE THERMOSTAT

HEAT PUMP PROGRAMMABLE THERMOSTAT HEAT PUMP PROGRAMMABLE THERMOSTAT SA PM 3 COOL TEMP Form 44014-01 r010408 Model 43168 Owners Manual 1 Congratulations! Heat Pump Programmable Thermostat Model 43168 THERMOSTAT CONTROLS Switches & Buttons...15

More information

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1 Model TRO24T4XYZ1 Description The TRO24T4XYZ1 is a combination controller and thermostat. The VAV Thermostat Controller is designed for simple and accurate control of any variable air volume box in a number

More information

GreenCon On/Off Room Thermostat

GreenCon On/Off Room Thermostat Description Features: Scandinavian design with white backlight; User-friendly interactive interface; Room temperature display and settings; 12 or 24 hour clock display and settings; Three-speed manual/automatic

More information

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE OWNER S MANUAL COMMERCIAL THERMOSTAT P/N P374-2800 I 2 : 0 0 Su AUTO Pm 74 COOL 7 2 HEAT T O T A L I N E HEAT COOL 7-DAY HEAT PUMP PROGRAMMABLE DIGITAL THERMOSTAT 3 Configurable Outputs Control up to 2

More information

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required. TTSIM-1A TraceTek Sensor Interface Module with Relay Installation Items (not supplied) General Information Installation/Operation Instructions Please read these instructions and keep them in a safe place.

More information

Installation Instructions

Installation Instructions T2 -PAC01 -A, T2 -NAC01 -A T2 -PHP01 -A, T2 -NHP01 -A LEGACYt SERIES THERMOSTATS Installation Instructions A07047 Legacy Series Programmable Thermostat A07046 Legacy Series Non-Programmable Thermostat

More information

GreenCon On/Off Room Thermostat

GreenCon On/Off Room Thermostat Description Features: Scandinavian design with white backlight; User-friendly interactive interface; Room temperature display and settings; 12 or 24 hour clock display and settings; Three-speed manual/automatic

More information

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference 3100 Premier Series Non-Programmable 2 Heat / 2Cool & Heat / Cool Digital Thermostat OWNERS MANUAL Compatible with low voltage multi-stage heat / cool systems with up to two stages of heating and two stages

More information

Label Displayed temperature Pb1 if the P4 parameter is set to 0, 1 or 2, room temperature if the P4 parameter is set to 3, incoming air temperature

Label Displayed temperature Pb1 if the P4 parameter is set to 0, 1 or 2, room temperature if the P4 parameter is set to 3, incoming air temperature EVCO S.p.A. EV3B24 Data sheet ver. 1.0 Code 1043B24E104 Page 1 of 6 PT 12/15 EV3B24 Basic controller for low temperature bottle coolers, cabinets, refrigerated cabinets, tables and pizza counters, with

More information

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC Viega Zone Control Applications The Viega Zone Control is a wiring and switching center for individual and / or multi- room control. The Zone Control simplifies wiring between Thermostats and Powerheads.

More information

Safety & Installation Instructions

Safety & Installation Instructions Model 8800 Universal Communicating Thermostat Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS Table of contents Installation Installation location recommendations... 2 Thermostat mounting...

More information

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features Product Guide MWS6-PRM Ceiling microwave presence/absence detector Overview The MWS6-PRM microwave presence detector provides automatic control of lighting loads with optional manual control. The MWS6-PRM

More information

RE-PR3-E-27 3-Phase Panel Mount 27kW

RE-PR3-E-27 3-Phase Panel Mount 27kW Page 1 of 6 RE-PR3-E-27 3-Phase Panel Mount 27kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting

More information

FX BLAST CHILLER ISO ISO 9001

FX BLAST CHILLER ISO ISO 9001 FX BLAST CHILLER ISO 14001 ISO 9001 Contents Environmental Management Policy 1 Disposal Requirements 1 Cabinet description 2 Controller Description Controller Operation 2 to 3 Alarms & Warnings 4 Parameter

More information

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

EBC20. Instructions for fitting, installation and operation. Read and save these instructions! EBC20 UK Instructions for fitting, installation and operation Read and save these instructions! 2 3002878 EBC20 UK 290415 1. Product information............................................... 4 1.1 Delivery.............................................................

More information

Model TZ43. ZWave Thermostat INSTALLATION AND OPERATION MANUAL DCN: /22/08 *** IMPORTANT NOTICE ***

Model TZ43. ZWave Thermostat INSTALLATION AND OPERATION MANUAL DCN: /22/08 *** IMPORTANT NOTICE *** RCS Model TZ43 ZWave Thermostat INSTALLATION AND OPERATION MANUAL DCN: 141-01652-03 9/22/08 *** IMPORTANT NOTICE *** DO NOT USE THIS PRODUCT FOR BUILDING FREEZE PROTECTION! YOU ARE ADVISED TO INSTALL A

More information

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Ceiling PIR HS presence detector. Product Guide. Overview. Features Product Guide 796-2047 Ceiling PIR HS presence detector Overview The 796-2047 (passive infrared) presence detector provides automatic control of lighting loads with optional manual control. This is a high

More information

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING Tempered Water Logic Control OPERATION l TROUBLE SHOOTING English For MPE Multiple Chiller Units Control Panel TEMPERED WATER SYSTEMS L-2199 Rev. 20080223 Revision: L-2199 20101104 *** IMPORTANT NOTICE

More information

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS VENSTAR FAN COIL THERMOSTAT FAN COIL THERMOSTAT T1070 NON- PROGRAMMABLE 2 OR 4 PIPE SYSTEMS Remote sensor ready 3 speed fan control Self-prompting adjustment Auto 2-pipe changeover when used with ACC-SENFC

More information

Digital Thermostat. Models: VS35W and VS35B INSTALLER / USER MANUAL

Digital Thermostat. Models: VS35W and VS35B INSTALLER / USER MANUAL Digital Thermostat Models: VS35W and VS35B INSTALLER / USER MANUAL Contents Contents Box Contents Introduction Product Compliance Installation User Guide Parameter Settings Installers Notes Warranty Icons

More information

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw Vertical Air-Cooled Split-System Cooling Units Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. 50VZ (40PZ/38VZ)

More information

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC Product Guide EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC Ceiling PIR presence/absence detector Overview The EBDSPIR-PRM-VFC PIR (passive infrared) presence detector provides automatic control of lighting loads

More information

WSK300 Multifunction Wall Control

WSK300 Multifunction Wall Control WSK300 Multifunction Installation & Operating Instructions WARNING Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions: Installation and

More information

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

Table of Contents. SLIMLINE Series MODEL: SLIMLINE Table of Contents Product Image 1 Table of Contents 2 What is a Programmable Room Thermostat? 3-4 Installation Procedure 5-6 LCD Display 7-8 Setting the Clock 9 Temperature Display 10 Setting the Comfort

More information

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings 0932EN October 2017 CHARACTERISTIC DATA Air flow rate [m 3 /h] 200 Pressure available (factory configuration) [Pa] 15 Moisture removed (26 C - 65% R.H. - inlet water 15 C) [l/24h] 24,7 Max. absorbed electric

More information

DXM CONTROLS. DXM Digital Heat Pump Controllers. Application, Operation, & Maintenance. Table of Contents

DXM CONTROLS. DXM Digital Heat Pump Controllers. Application, Operation, & Maintenance. Table of Contents Table of Contents DXM CONTROLS DXM Electronic Controls Features Comparison 2 DXM Electronic Heat Pump Controls 3 DXM Physical Dimensions & Layout 4 DXM Controls 5 DXM Service & Application Notes 13 Troubleshooting

More information

Heat Pump Defrost Board Replacement Kit

Heat Pump Defrost Board Replacement Kit Bard Manufacturing Company, Inc. Bryan, Ohio 43506 8620-223 Heat Pump Defrost Board Replacement Kit KIT FEATURES This kit is made up of the current defrost control board 8201-129 and a new defrost sensor.

More information

SAS6000UTK-7 UNIVERSAL THERMOSTAT

SAS6000UTK-7 UNIVERSAL THERMOSTAT SAS6000UTK-7 UNIVERSAL THERMOSTAT Used with Single Stage, Multi-Stage, Heat pump Installation and operation instructions SPECIFICATION: Power Supply Dual Power 24VAC (18-30VAC,50/60Hz) or Battery Powered

More information

T8011R Programmable Heat Pump Thermostat

T8011R Programmable Heat Pump Thermostat T8011R Programmable Heat Pump Thermostat FEATURES PRODUCT DATA APPLICATION The T8011R Heat Pump Thermostat provides 24 Vac control of a two-stage heating and one-stage cooling heat pump system with manual

More information

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits CommStat 4 PRODUCT DATA SHEET Controller for Redundant Telecom HVAC Systems General Description The CommStat 4 is an HVAC controller designed specifically for controlling two redundant air conditioners,

More information

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features Product Guide VITMR-EBDSPIR-PRM PIR Presence/Absence Detector IR with Ceiling Rose Overview The VITMR-EBDSPIR-PRM PIR (passive infrared) presence detector provides automatic control of lighting loads.

More information

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB Summary 1 CONNECTIONS... 3 1.1 TEMPERATURE PROBES...3 1.2 LOW VOLTAGE DIGITAL INPUTS...3 1.3 LIVE DIGITAL INPUTS...4 1.4 RELAY OUTPUTS...5 2 POWER SUPPLY... 6 3 SERIAL CONNECTIONS... 6 4 SOFTWARE... 7

More information

OWNER S MANUAL Venstar Inc. 08/07

OWNER S MANUAL Venstar Inc. 08/07 Digital Thermostat commercial SCHOOL THERMOSTAT T2900SCH MABLE up to 3-heat & 2-cool HEAT COOL HEAT PUMP Energy Saving Operation Morning Warm-up Period Programmable Override Unoccupied until button press

More information

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features Product Guide PPAD-C-230V Ceiling PIR presence/absence detector Overview The PPAD-C-230V passive infrared presence detector provides automatic control of lighting loads with optional manual control. The

More information

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY Table of Contents Non-Programmable Heat Pump Thermostat Installation Manual 97B0082N06 Revised: 16 September, 2013 Safety Considerations 3 General 3 Package Contents 3 Installation Considerations 3 Power

More information