Le Bon Table Z-CAC. Controlled Atmosphere Container

Size: px
Start display at page:

Download "Le Bon Table Z-CAC. Controlled Atmosphere Container"

Transcription

1 Le Bon Table Z-CAC Controlled Atmosphere Container

2 The Industry Standard for Quality, Reliability, and Performance.

3 TIMES HAVE CHANGED With the Le Bon Table Z-CAC, growers can harvest their product closer to maturity and peek flavor, place their inventory in our container, close the door and literally suspend the maturation of their goods. It gives shippers better flexibility when transporting goods to distant markets. And, it improves quality and increases consumer appeal. The Le Bon Table Z-CAC Controlled Atmosphere Container (CAC) stands above any other. As you re aware, airfreight is expensive and cost prohibitive. And, nitrogen gas injections, which are costly per trip degrades over time, and is not available worldwide. Integrated into the Le Bon Table Z-CAC refrigeration unit is a controlled atmosphere system which provides continuous protection for perishable cargo and minimizes costs. Integrated into the Z-CAC, our unit produces its own nitrogen, continuously controlling the atmospheric conditions inside the container. To appreciate the real value of this technology, you have to understand how it works. Continuous, precise management of gasses in the atmosphere surrounding a growers cargo as such as produce, significantly reduces product respiration of ethylene and slows natural ripening. This extends product life, minimizes product degradation and spoilage, and ensures maximum quality on delivery. It also inhibits bacterial growth and help control insect infestation. Basically, the Z-CAC adds weeks, even months of shelf life to specific perishables such as fruits and vegetables. What makes the Z-CAC stands alone in the industry is the inner container lining. Sure, all of the conglomerate Cargo transport companies claim to have controlled atmosphere containers, but none of these conglomerate containers comes close to the Z-CAC. Our secret is in the inner lining of the container. It is permeated with a natural mineral compound which seeks out and destroys any ethylene gas before it destroys product. Suspended animation virtually.

4 The Japanese have unwittingly used this Mineral for years, as they stored their vegetables in mountainside caves on Mount Fuji, retarding the aging process of their produce. They ve always presumed that it was the coolness of the mountain (which was covered in snow year round) that preserved their crops. But, in the laboratory, it was discovered that this mineral, which is found to be on the inside of the walls of the caves, and, when it is used in a controlled environment such as the Le Bon Table Z-CAC, it literally suspended the ripening of a load of apples adding a couple of months to its normal shelf life. Thus, the grower can leave their crops to ripen longer and harvest later. Imagine the possibilities? Crops are larger, weightier, higher in sugar content, better tasting, and higher in nutritional value. For the shipper, premium cargo care means premium quality, satisfied customers and greater revenue. At Le Bon Table, our exclusive controlled atmosphere container will do its utmost to ensure field-ripe flavor on delivery. Virtually a smooth operation and dependable performance would make it the first choice of growers, shippers, and importers worldwide. Because, they know our quality product won t just bring their cargo in It brings revenue in added revenue. SAFE PASSAGE AND STORAGE is why so many people should be depending on the Le Bon Table Z-CAC for years to come. The Z-CAC is delivered to your site fully equipped with a Carrier

5 Thin Line Cooling System which houses a unique 06D semi hermetic compressor. The compressors proven reliability has made it the workhorse of the industry. The 06D stroke has been increased to move more refrigerant through its interior, keeping a constant, cool temperature throughout he voyage of the cargo. Designed to handle the rigors of container refrigeration, the 06D has become the standard throughout the industry. 06D facts: Exclusive canted valves and contoured pistons reduce clearance volume to maximize volumetric efficiency, especially at low box temperatures. Vented connecting rods improve bearing lubrication. Crankcase pressure equalizing tube and spinner tube assembly, balance crankcase and system pressures to maintain a high oil level in the compressor, even during startup. Lube oil passages on bearing surfaces increase oil circulation to internal bearing and running gear surfaces under all operating conditions. Oil pressure regulator maintains constant oil pressure to ensure optimum lubrication of all moving parts. The compressor is backed by a three year warranty to protect you from expensive repairs. The Z-CAC facts: Advanced Carrier 06D semi hermetic compressor Data recorder Back lit LCD displays Time delay motor start sequence Zero ODP Refrigerant Exclusive stepper modulation capacity control High efficiency evaporator and condenser coils Electro-statically coated all copper condenser coil System is wired for 380/460 volt-3ph-50/60hz power Safe 24 volt AC control circuit with fuse protection Cool, Heat, Defrost, In Range, Alarm indicator lights

6 Main power circuit breaker 60 ft. power cable with attached CEE-17 plug Electric heat Manual defrost initiation switch Energy saving Condenser Pressure Control Energy saving Economy mode evaporator motor logic Composite control box Ever Fresh Advanced cargo protection maintains a constant balance of oxygen and carbon dioxide Rechargeable power up battery pack Remote monitoring receptacle System temperature sensors Pressure transducers Fresh air vent positioning sensors Emergency bypass system MICRO LINK, temperature control unit Available in 40 Container lengths. Le Bon Table will also build stationary units to your specifications. TEMPERATURE CONTROL ATMOSPHERE CONTROL HUMIDITY CONTROL PEST CONTROL ETHYLENE CONTROL Extends Life of Perishable Products: From To (Example) Red Washington Delicious Apples 4 weeks 12 weeks Avocados 6 weeks 16 weeks Banana 4 weeks 10 weeks Bing Cherries 3 weeks 9 weeks For Further Information Contact Gino (888) A product of Le Bon Table Brand Foods Corp. (a publicly traded company LBTF )

ThinLINE. The industry standard for quality, reliability, and performance.

ThinLINE. The industry standard for quality, reliability, and performance. ThinLINE The industry standard for quality, reliability, and performance. ThinLINE More growers and shippers depend on the ThinLINE unit. Safe passage under all conditions. That s why so many people depend

More information

NaturaLINE The world s first natural refrigerant unit for container refrigeration.

NaturaLINE The world s first natural refrigerant unit for container refrigeration. NaturaLINE NaturaLINE The world s first natural refrigerant unit for container refrigeration. The NaturaLINE container refrigeration unit was purposefully designed for shipping lines seeking sustainable

More information

Air-Cooled Condensing Units with Compact Screw Compressors

Air-Cooled Condensing Units with Compact Screw Compressors LK-SCUTB March 2015 Air-Cooled Condensing Units with Compact Screw s Technical Bulletin Models SSV DSV Table of Contents Nomenclature Chart... 2 Introduction... 3 Bitzer TM s... 4 Magnum TM Microprocessor...

More information

Postharvest Goals. Postharvest Physiology and Quality of Horticultural Crops

Postharvest Goals. Postharvest Physiology and Quality of Horticultural Crops Postharvest Physiology and Quality of Horticultural Crops Mark Ritenour University of Florida Indian River Research and Education Center What is Postharvest Biology? A Pragmatic (practical) science. Primarily

More information

Postharvest Physiology & Quality of Horticultural Crops

Postharvest Physiology & Quality of Horticultural Crops Postharvest Physiology & Quality of Horticultural Crops Mark Ritenour Indian River Research and Education Center, Fort Pierce Causes of Postharvest Loss Environmental Factors Temperature Physical damage

More information

Postharvest technologies for the developing world

Postharvest technologies for the developing world Postharvest technologies for the developing world Forum on postharvest practices UC Washington Center Michael Reid, UC Davis Food supply depends on better postharvest technology Losses are high Perishables

More information

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features. Spot Cooling Systems, Inc. 120 Century Drive Suite 00 Carrollton, TX 7006 00-6-776 Operation Manual SCT1B and SCT1B Warning! Improper installation, adjustment, alteration, service, or maintenance can cause

More information

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

DOWNLOAD PDF DESIGN OF COLD STORAGE FOR FRUITS AND VEGETABLES

DOWNLOAD PDF DESIGN OF COLD STORAGE FOR FRUITS AND VEGETABLES Chapter 1 : Cold Storage Fruit: Cold Room Panels for Fruit Cold Storage The cold storage of dried/dehydrated vegetables in order to maintain vitamin C, storage temperature can be varied with storage time

More information

Astronaut ice cream, anyone

Astronaut ice cream, anyone Reading Practice Astronaut ice cream, anyone Breezedrying is a technique that can help to provide food for astronauts. But it also has other applications nearer home. Freezedrying is like suspended animation

More information

.2 Section Waste Management and Disposal.

.2 Section Waste Management and Disposal. Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

Carrier Transicold GENESIS. MAXIMUM performance. and PROTECTION. in multi-temperature trailers.

Carrier Transicold GENESIS. MAXIMUM performance. and PROTECTION. in multi-temperature trailers. Carrier Transicold GENESIS MAXIMUM performance and PROTECTION in multi-temperature trailers. GENESIS. Nothing PROTECTS your multi-temp cargoes BETTER. The growing complexity of the grocery business has

More information

Postharvest Handling of Berries

Postharvest Handling of Berries Postharvest Handling of Berries Eleni D. Pliakoni, Ph.D Assistant Professor, Kansas State University http://www.organicauthority.com/organic-berries-and-bagged-salads-top-organic-produce-sales/ Berries

More information

EliteLINE. Premium cargo protection. Premium environmental responsibility.

EliteLINE. Premium cargo protection. Premium environmental responsibility. EliteLINE Premium cargo protection. Premium environmental responsibility. EliteLINE The inspiration for a system that s safer for nature came from nature. Chambered Nautilus Nautilus Pompilius The chambered

More information

Chapter-8 Capacity Control of Refrigeration Systems

Chapter-8 Capacity Control of Refrigeration Systems Chapter-8 Capacity Control of Refrigeration Systems Chapter-8 Capacity Control of Refrigeration Systems ၈.၁ Compressor Control Chiller Control and Chilled Water Plant Control Refrigeration system control

More information

STAR YOUR OWN COLD STORAGE UNIT

STAR YOUR OWN COLD STORAGE UNIT STAR YOUR OWN COLD STORAGE UNIT SPECIAL FEATURES OF COLD STORAGE PROJECT Priority Sector as per Govt. Policy Easy Financing Facilities Easy to Manage Only Fixed Assets Investments High Rate of Return High

More information

Clean, Silent and Efficient Refrigeration Solutions for Distribution and City Operations

Clean, Silent and Efficient Refrigeration Solutions for Distribution and City Operations Clean, Silent and Efficient Refrigeration Solutions for Distribution and City Operations Trailer Refrigeration Multi Temperature Truck Refrigeration Single and Multi Temperature Lowest environmental impact

More information

With the world-renowned SIGMA PROFILE

With the world-renowned SIGMA PROFILE www.kaeser.com Rotary Screw Compressors BSD/CSD/CSDX T SFC Series With the world-renowned SIGMA PROFILE Free air delivery 0.87 to 16.10 m³/min, Pressures 5.5 to 15 11 What do you look for in a compressor

More information

Post-harvest Asparagus Handling

Post-harvest Asparagus Handling Post-harvest Asparagus Handling Your produce much less perishable Su producto mucho menos perecedero November 2010 Ivo Tunchel Minimize Temperature Damage Immediately After Harvest Pack in well ventilated

More information

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump Catalogue MAC-D-2013 (50Hz) MAC-D R410A Series Air-cooled Modular Chiller/Heat pump Model: Refrigerant: Cooling Capacity: Heating Capacity: MAC210D5-MAC1680D5 MAC230D5-MAC1840D5 MAC210DR5-MAC1680DR5 MAC230DR5-MAC1840DR5

More information

30GT FLOTRONIC AIR-COOLED CHILLERS

30GT FLOTRONIC AIR-COOLED CHILLERS 30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed

More information

Air Conditioning Operation and Troubleshooting Matt Dunham

Air Conditioning Operation and Troubleshooting Matt Dunham Air Conditioning Operation and Troubleshooting Matt Dunham Major Components (10 Minutes) Compressor heart of the system, causes refrigerant to flow by increasing the pressure of the refrigerant Metering

More information

of the year it can be used as a tabletop oven. GUIDELINES Speed

of the year it can be used as a tabletop oven. GUIDELINES Speed Food Drying Basics Drying is the oldest method of preserving food. The early American settlers dried foods such as corn, apple slices, currants, grapes, and meat. Compared with other methods, drying is

More information

Postharvest Deterioration and Losses

Postharvest Deterioration and Losses Principles of Postharvest Horticulture University of Florida Postharvest Deterioration and Losses Mark Ritenour Indian River Research and Education Center, Fort Pierce Jeff Brecht Horticultural Science

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

PDF Created with deskpdf PDF Writer - Trial ::

PDF Created with deskpdf PDF Writer - Trial :: Instruction Manual Index Introduction Uncrating and Checking for Damage Locating Your Unit Installation Fill Tank Process Connections Pre Startup Startup Sequence Trouble Shooting Chart Operating Lights

More information

Air-Cooled Condensing Units with Bitzer Compressors

Air-Cooled Condensing Units with Bitzer Compressors CH-CUBZTB JAN 2018 Replaces CH-CUBZTB APRIL 2011 Air-Cooled Condensing Units with Bitzer s Technical Guide s BLV BDVS JLD JDDS Table of Contents Floating Tube Coil... 3 Beacon II Options... 4 Adjustable

More information

30GN FLOTRONIC II AIR-COOLED CHILLERS

30GN FLOTRONIC II AIR-COOLED CHILLERS 30GN-19SB 30GN040-110 FLOTRONIC II AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GN-19SB Supersedes 30GN-6SB, 30GN-7SB, 30GN-8SB, Printed

More information

AQUASNAP JUNIOR 30RHV

AQUASNAP JUNIOR 30RHV High-Efficiency Air-To-Water Heat Pumps Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. AQUASNAP JUNIOR 3RHV 6-11

More information

OIL-FREE ROTARY SCREW COMPRESSORS Fixed Speed Regulated Speed (RS) D75 D275 INTELLIGENT AIR TECHNOLOGY

OIL-FREE ROTARY SCREW COMPRESSORS Fixed Speed Regulated Speed (RS) D75 D275 INTELLIGENT AIR TECHNOLOGY 03 OIL-FREE ROTARY SCREW COMPRESSORS Fixed Speed Regulated Speed (RS) D75 D275 INTELLIGENT AIR TECHNOLOGY D75 D275 OIL-FREE ROTARY SCREW COMPRESSORS AIR & WATER COOLED FIXED & REGULATED SPEED The CompAir

More information

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: 40-158 kw Nominal heating capacity: 41-159 kw Carrier China Carrier Corporation is a subsidiary of the United Technologies

More information

PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer

PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer 5/16 Rev. A 57-02509 2 Contents INTRODUCTION... 4 WARNING LABELS AND SAFETY INSTRUCTIONS... 5 PS SERIES PARALLEL

More information

Challenges in Postharvest Handling of Tropical Fruit. Beth Mitcham University of California

Challenges in Postharvest Handling of Tropical Fruit. Beth Mitcham University of California Challenges in Postharvest Handling of Tropical Fruit Beth Mitcham University of California Characteristics of Horticultural Crops High water content Easily damaged Alive a biological system Deterioration

More information

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw) Product Data 38AH024-134 Commercial Air-Cooled Condensing Units 50/60 Hz 20 to 130 Nominal Tons (63 to 390 Nominal kw) a38-4143ef 38AH044-134 These dependable split systems match Carrier s 40RM or 39 Series

More information

Premium Efficient OIL-FREE Compressors

Premium Efficient OIL-FREE Compressors Oil-Free, Rotary Screw Air Compressors Premium Efficient OIL-FREE Compressors Two-Stage Air-Cooled Water-Cooled Fixed Speed or VFD 20-500 HP 72-2400 SCFM 40-150 PSIG knw-series.com Rogers Machinery Company,

More information

High Speed Turbo: the new benchmark for oil-free compressed air

High Speed Turbo: the new benchmark for oil-free compressed air The food and drink sector relies heavily on compressed air systems to power its process, production and packaging lines, with the compressed air system of choice often being designated as oil-free. Oil-free

More information

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw AIR-COOLED LIQUID CHILLER REVERSIBLE AIR-TO-WATER HEAT PUMP PRO-DIALOG PLUS 30RB/RQ 039S-60S Refrigerant HFC-40A Nominal cooling capacity 40-58 kw Nominal heating capacity 4-59 kw The new generation of

More information

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

HYDROCIAT LW R407C. Water cooled chillers USE RANGE Screw compressors CIAT dry direct expansion shell and tubes evaporator HPS equipment (High Power System) cooling or heating Heat recovery ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT

More information

50TM TFF COMBINATION HEATING/COOLING UNITS

50TM TFF COMBINATION HEATING/COOLING UNITS 50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York

More information

Wiring Diagrams Units Produced After April 20, 2009

Wiring Diagrams Units Produced After April 20, 2009 UNIT 38AH 0-034 Wiring Diagrams Units Produced After April 20, 2009 (Includes Variable Air Volume ModuPanel Control) ELECTRICAL CHARACTERISTICS (V-Ph-Hz) 208/-3-60, 460-3-60 575-3-60 380-3-60-3-50, 380/415-3-50

More information

An efficient solution for more comfortable environments

An efficient solution for more comfortable environments ROOFTOP AHU AIR CONDITIONERS PACKAGE AIR CONDITIONERS An efficient solution for more comfortable environments Grande Rooftop Package Air Conditioners With R410A (50HZ) ROOF TOP PACKAGE AIR CONDITIONERS

More information

Air Cooled Packaged Systems AIRAH Back to Basics

Air Cooled Packaged Systems AIRAH Back to Basics Air Cooled Packaged Systems AIRAH Back to Basics What s changed? New Refrigerants R410a MEPS EER / AEER / SEER Manufacturing Technologies Research, Development and Testing New technologies, controls, reliability

More information

50TM COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS 50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form

More information

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems.

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems. Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems. The DRY-30 Series Dehumidifiers, like all equipment manufactured by DryAire Systems combines more standard features

More information

The Book of AERMEC NRL Sequence of Operation

The Book of AERMEC NRL Sequence of Operation The Book of AERMEC NRL Sequence of Operation Heating and cooling operation. 2 Sequence of operation Aermec air to water chiller/heat pump use Hydronic s in conjunction with refrigerant to provide heating

More information

Daikin LXE10E Technical Information

Daikin LXE10E Technical Information Daikin LXE10E Technical Information Model shown above is the DAIKIN LXE10E-A15 (Fitted with Transfresh Provision option.) Page 1 of 9 23/11/2006 The most important part of any refrigeration machine is

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION MODULAR AIR HANDLER MODEL: N*AH CONTENTS GENERAL... 1 INSPECTION... 2 REFERENCE... 2 LIMITATIONS... 2 LOCATION... 2 BLOWER/COIL ASSEMBLY UPFLOW AND HORIZONTAL INSTALLATIONS...

More information

Unit D: Fruit and Vegetable Crop Production. Lesson 4: Growing and Maintaining Tree Fruits

Unit D: Fruit and Vegetable Crop Production. Lesson 4: Growing and Maintaining Tree Fruits Unit D: Fruit and Vegetable Crop Production Lesson 4: Growing and Maintaining Tree Fruits 1 Terms Bud scars Budding Double dwarf trees Dwarf trees Fruit thinning Fruiting habit Grafting Heading back (tipping)

More information

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems.

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems. Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems. The DRY-40A Series Dehumidifiers, like all equipment manufactured by DryAire Systems combines more standard features

More information

Why Modify the Environment?

Why Modify the Environment? Dr. Richard G. Snyder Dr. Richard G. Snyder Professor & Vegetable Specialist Greenhouses are for Environmental Modification temperature light insects, diseases, and weeds air pollutants water Why Modify

More information

Be sustainable while protecting your business

Be sustainable while protecting your business Be sustainable while protecting your business Aquaflair 50Hz Air-cooled chillers and free-cooling chillers with double screw compressors and HFO R1234ze refrigerant (400V/3ph/50Hz) 300-1000 kw Aquaflair

More information

13 GEP A L P - 1 A

13 GEP A L P - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800

More information

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement. AHF / AHK SERIES AIR HANDLING UNITS INSTALLATION GUIDE GENERAL The AHF / AHK series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the

More information

V-Series. Superior Temperature Control for Small Trucks and Vans

V-Series. Superior Temperature Control for Small Trucks and Vans V-Series Superior Temperature Control for Small Trucks and Vans Modern compact platform User-friendly Direct Smart Reefer Increased reliability Easy maintenance, service and installation Enhanced performance

More information

Cycling Evaporator Fans to Reduce Energy Costs in Controlled Atmosphere Storage

Cycling Evaporator Fans to Reduce Energy Costs in Controlled Atmosphere Storage ~~ Cycling Evaporator Fans to Reduce Energy Costs in Controlled Atmosphere Storage C ontrolled atmosphere refrigeration systems are sized to rapidly remove field heat from fruit after harvest. Afterfield

More information

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION CONDITIONERS DRY CHARGE UNITS PRODUCT SPECIFICATIONS Bulletin No. 20636 May 204 Supersedes March 202.5 to 5 Tons MODEL NUMBER IDENTIFICATION L C S 3 DC - 036-230 - 2 Lennox Minor Revision Number Air Conditioner

More information

30HXC-HP Water-to-water Screw Heat Punp. Nominal cooling capacity: 460~1283 kw Nominal heating capacity: 498~1591 kw

30HXC-HP Water-to-water Screw Heat Punp. Nominal cooling capacity: 460~1283 kw Nominal heating capacity: 498~1591 kw Water-to-water Screw Heat Punp Nominal cooling capacity: 460~1283 kw Nominal heating capacity: 498~1591 kw Carrier China Carrier Corporation is a subsidiary of the United Technologies Corp. (UTC), which

More information

CONTAINER REFRIGERATION UNIT TECHNICAL SPECIFICATIONS. Model 69NT

CONTAINER REFRIGERATION UNIT TECHNICAL SPECIFICATIONS. Model 69NT CONTAINER REFRIGERATION UNIT TECHNICAL SPECIFICATIONS Model 69NT40-541-500 Jan 2015 TABLE OF CONTENTS 1. UNIT PERFORMANCE... 1 1.1. Net R-134a Refrigeration Cooling Capacity... 1 1.2. Evaporator Airflow

More information

Emerging Technologies: VFDs for Condensers. Douglas T. Reindl Director, IRC University of Wisconsin-Madison. University of Wisconsin-Madison

Emerging Technologies: VFDs for Condensers. Douglas T. Reindl Director, IRC University of Wisconsin-Madison. University of Wisconsin-Madison Emerging Technologies: VFDs for Condensers Douglas T. Reindl Director, IRC University of Wisconsin-Madison University of Wisconsin-Madison 1 We ve looked at VFDs on Evaporators and compressors, what is

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

V Series. Superior Temperature Control. Small trucks and vans

V Series. Superior Temperature Control. Small trucks and vans V Series Superior Temperature Control Small trucks and vans Modern compact platform User friendly Direct Smart Reefer Increased reliability Easy maintenance, service and installation Content Introduction

More information

Final Exam 200 points possible

Final Exam 200 points possible PRINCIPLES OF POSTHARVEST HORTICULTURE Final Exam 200 points possible 2018 NAME: Total of 200 points possible. I. COMMODITY SECTION (99 points) FINAL EXAM (11 points) SUBTROPICAL FRUITS (MAR) (1 point)

More information

HVAC/R Refrigerant Cycle Basics

HVAC/R Refrigerant Cycle Basics HVAC/R Refrigerant Cycle Basics This is a basic overview of the refrigeration circuit and how it works. It isn t a COMPLETE description by any means, but it is designed to assist a new technician or HVAC/R

More information

AE R1 March 1993 Reformatted November Compressor Overheating

AE R1 March 1993 Reformatted November Compressor Overheating AE17-1260 R1 March 1993 Reformatted November 2010 Compressor Overheating It is ironic that in an industry whose product is cooling and refrigeration, the most serious field problems arise from overheating

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with NOVATIONt Coil Sizes 08, 12, 14 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED

More information

InstructIon Manual KrEs EQuIPMEnt stands

InstructIon Manual KrEs EQuIPMEnt stands Instruction Manual Instruction Manual SELF-CONTAINED AND REMOTE Kairak KRES model refrigerated equipment stand units are available in many lengths from 36 to 120 inches long. These units are available

More information

30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz

30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz 30GXN-3SB 30GXN,R080-528 AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz PERFORMANCE DATA S FIELD WIRING DIAGRAMS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form 30GXN-3SB

More information

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N PROAIR Air Conditioner CR29 Model INSTRUCTION MANUAL Rev. I P/N 89104461 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

SINGLE STAGE MULTI STAGE NANO MICRO

SINGLE STAGE MULTI STAGE NANO MICRO SINGLE STAGE Single stage air-cooled chillers are built with a compact design that is simple to operate and maintain. All chillers are built on a rugged and fully welded, powder coated steel platform,

More information

Booster Compressors N Series. Pressures to 650 psig Capacities 9.5 to 724 cfm

Booster Compressors N Series. Pressures to 650 psig Capacities 9.5 to 724 cfm Booster Compressors N Series Pressures to 650 psig Capacities 9.5 to 724 cfm High Pressure Systems from Kaeser PET plastics, molding, leak testing and other special applications require higher pressures

More information

3 0 H X C A - H P 2

3 0 H X C A - H P 2 3 0 H X C 1 3 0 A - H P 2 Max. Leaving Water Temperature (Heating Mode) 1 for 47 O C,2 for 60 O C Water-to-Water Screw Heat Pump 3 rd Generation Global Water Cooled Chiller Norminal Capacity (USRT) Carrier

More information

Commercial Maintenance Agreement (CMA) Benefits

Commercial Maintenance Agreement (CMA) Benefits Commercial Maintenance Agreement (CMA) A Program Designed to Reduce Your Utility and Repair Costs Benefits DISCOUNT: The Company will provide a 10% discount on all repair parts. Emergency labor will be

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS CROWN Boiler Co Santa-Fe Series Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS These instructions must be affixed on or adjacent to the air handler Models: SAC049A20 SAC059A25

More information

APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models)

APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models) 4-1280 Application Engineering Bulletin AE-1280R4 Revised April, 1995 APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models) Introduction The Compliant Scroll Compressor has been

More information

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT 50HJQ-11SB 50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

SECTION AIR COMPRESSORS AND ACCESSORIES

SECTION AIR COMPRESSORS AND ACCESSORIES PART 1 GENERAL 1.01 WORK INCLUDED SECTION 11370 AIR COMPRESSORS AND ACCESSORIES A. This specification includes air compressors with air dryers. B. Furnish, install, start-up, and test air compressors and

More information

HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI

HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI NO. S051-800 ISSUED: MAR. 26, 2010 REVISED: HOSHIZAKI COUNTER SHOWCASE MODEL HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B SERVICE MANUAL IMPORTANT This manual should be read carefully

More information

9. Temperature, Relative humidity (% RH) control and use of the Psychrometric chart.

9. Temperature, Relative humidity (% RH) control and use of the Psychrometric chart. 4.3.1 8. Cooling Cold requirement of Apples and Pears Certain pears have a cold requirement that must be overcome or met during storage. For most pear cultivars, direct cooling and packing provides adequate

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N PROAIR Air Conditioner CR23 Model INSTRUCTION MANUAL Rev. D P/N 89112522 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM LABORATORY FREE ZERS LABORATORY FREEZERS -30 O C i.series TM Horizon Series TM introduction LABORATORY FREEZERS -30 O C helmer laboratory freezers provide the following benefits: Programmable Defrost Times

More information

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ E3FB090/E1FB120/F3EH090 & 120 7-1/2 & 10 NOMINAL TONS (60 HZ) 7 & 9 NOMINAL TONS (50 HZ) (9.0-9.2 EER) 208/230/460 VOLT ONLY 208/230 VOLT ONLY DESCRIPTION YORK has

More information

Technical Review. Remote Condenser Cuber. Enhanced Refrigeration and Water Systems. CM 3 Technology. of a. with. using. models included are:

Technical Review. Remote Condenser Cuber. Enhanced Refrigeration and Water Systems. CM 3 Technology. of a. with. using. models included are: Technical Review of a Remote Condenser Cuber with Enhanced Refrigeration and Water Systems using CM 3 Technology models included are: CME1356 shown on BH900 CME456, CME1056, CME1356, CME1656 and CME2006

More information

A Design for True Performance and Energy Savings In Refrigerated Compressed Air Dryers The Digital Scroll Dryer

A Design for True Performance and Energy Savings In Refrigerated Compressed Air Dryers The Digital Scroll Dryer A Design for True Performance and Energy Savings In Refrigerated Compressed Air Dryers The Digital Scroll Dryer Introduction By Timothy J. Fox, P.E. Hankison, an SPX Brand Canonsburg, Pennsylvania Refrigerated

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

Call us today! (800)

Call us today! (800) 150 TON AIR-COOLED CHILLER PA-ACCTR-150 Call us today! (800)341-4297 The 150-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

G124X - G234X - G334X Atmospheric Gas Boilers

G124X - G234X - G334X Atmospheric Gas Boilers G124X - G234X - G334X Atmospheric Gas Boilers Setting the Standard for Efficiency High Efficiency: Full line of Atmospheric Gas Boilers Flexible, Corrosion Resistant GL-180M Cast Iron Limited Lifetime

More information

RoofPak Applied Rooftop Systems

RoofPak Applied Rooftop Systems RoofPak Applied Rooftop Systems RoofPak Applied Rooftop Systems Design flexibility, energy efficiency, system performance and reliability make Daikin RoofPak applied rooftop systems the ideal solution

More information

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration Calhoon MEBA Engineering School Study Guide for Proficiency Testing Refrigeration 1. To prevent an injury when working with refrigerants, what safety precautions are necessary? 2. When halogens are in

More information

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units. SECTION 15650 REFRIGERATION PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units. 4. Air

More information

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS 48HJ-13SB Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT

More information

Contour TM Screw Compressors

Contour TM Screw Compressors Contour TM Screw Compressors Semi-Hermetic Compact Operating Instruction SCH1 High Temp Compressors Form No. 99-77 1. Introduction This series of semi-hermetic compact screw compressors is designed for

More information

Ripening Temperature Management

Ripening Temperature Management (c) 25 Postharvest Technology Center, UC Davis Ripening Temperature Management Jeff Brecht Horticultural Sciences Department University of Florida jkbrecht@ufl.edu Fruit Ripening and Retail Handling Workshop

More information

Emerson Superheat Control. The smart solution for your application

Emerson Superheat Control. The smart solution for your application Emerson Superheat Control The smart solution for your application Trust in Emerson Climate Technologies for reliable, precise and efficient superheat control. When it comes to superheat control, Emerson

More information

Plant Growth Chamber MPGR14

Plant Growth Chamber MPGR14 Plant Growth Chamber Product Overview/Applications The provides a 14 ft2 growth area and a 58 inch growth height making this chamber suitable for a range of applications including plant science, bioengineering,

More information