HOT WATER VAPORIZER "FEED-BACK"

Size: px
Start display at page:

Download "HOT WATER VAPORIZER "FEED-BACK""

Transcription

1 HOT VAPORIZER "FEED-ACK" "CALOVAP" Unit CALOrific for hot water VAPorizer Safety device on water circuit PREVENT THE LPG TO PASS IN THE HOT CIRCUIT IN CASE OF LEAK IN THE EXCHANGE TUE OF THE VAPORIZER For Propane, utane or LPG-Mixtures Conforms to CODAP (Pressure Vessel Codes) All-Welded Design Flanged connections Factory primed, painted, tested Complete with all controls and safeties "VAPINDUS" Hot Water FEED-ACK Vaporizer Safe : No liquid entering the vapour supply (No Solenoid valve and no float for liquid carryover protection) Zone Industrielle Nord-Est 5, Rue des Petits Ruisseaux VERRIERES LE UISSON FRANCE Phone : [33] (0) Fax : [33] (0) engigaz@wanadoo.fr Web :

2 HOT VAPORIZER "FEED-ACK" VAPINDUS OPERATION The vaporizer FEED-ACK VAPINDUS works on the principle of natural convection where natural heat influx is supplemented by the vaporizer, increasing the vapor pressure within the storage tank to provide sufficient vapor for the heating load. Heat required to vaporize the LP-Gas liquid is supplied by an external hot water source such an ENGIGAZ CALOVAP. This hot water source (provide by a water pump) is turned on and off by a regulation pressure switch that controls storage pressure. During the operation, hot water enters in the heat exchanger at the temperature rated 85 C (). When liquid LPG inside the vaporizer shell comes in contact with the tube bundle, boiling of the LPG results.the cooled water returns to the hot water heater after passing through the tube bundle. The vaporized LPG passes throught the heat exchanger and exists througt the outlet to the tank. Optionals pressures switches (low and high pressure) ensure the safety of the vaporizer in case of faulty operation of regulation pressure switch, water pump and hot water heater(s). The water network system must be filled with a mixture of fresh clean water and anti-freeze (glycol containing anticorrosion liquids). eg : for Propane, the regulation pressure switch is setting between 4 bar and 4,5 bar (Differential of the pressure switch is adjustable - setting : 0,5 b). If storage pressure is below 4 bar Water pump : ON If storage pressure is above 4,5 bar Water pump : OFF This on-off cycle is always repeated to maintain the tank pressure between 4 and 4,5 bar regardless of the LPG consumption NON EEx ZONE EEx ZONE CALOrific unit for VAPorizer CALOVAP First Stage Regulator Chemney P Remote Control Panel Pump Expansion Vase Gas ox - Regulator - Stop valve Pressure switches j P P P Hot Water Heater Safety device

3 Safety HOT VAPORIZER "FEED-ACK" R E Safety Relief Valve C D Pressure switch LPG Vapour ØJ S Cooled T X L G H W I K P ØV F LPG Liquid * Vaporizer VAPINDUS are rated for : Propane liquide : 0 C Pressure to maintain inside Tank(s) : 4 bar Hot Water : : 85 C - : 65 C Q Hot U N O M Designs and specifications are subject to change without notice or obligation FLOW * A STANDARD FEATURES Designed and manufactured per CODAP95 pressure vessel codes LPG Vessel : 37,5 bar Explosion-proof (EEx) meets EN & EN50018 Features and outlet ball valves EEx Regulation pressure switch Safety relief valves Safety device water circuit CONCRETE C D E F G H I J K L M N O P Q R S T FIXING U V W X Ø axis "M 1"F Ø Ø Ø axis Ø * 50 * 168 axis Ø14 Additional Features EEx Excess pressure switch (acting as overpressure protection, interrupting all water circulation to the unit) EEx Low pressure switch (acting as an remote alarm)

4 CALORIFIC UNIT FOR VAPORIZER G H I C D LPG Vapour M A J L N K F Hot E Cooled MODEL HOT HEATERS x 40 Kwh x 40 Kwh x 40 Kwh x 2 x 40 Kwh x 3 x 40 Kwh CHASSIS Ø GAS Ø CAINET ALUMINIUM CONCRETE MODEL A C D E PN25 DN CALOVAP FIXING F G H I J K L M N Ø (1) PN25 DN / M / M / M / M /4 50 * 50 * M16 STANDARD FEATURES Circulating water pump Water pressure switch Water safety relief valve,automatic air vents Expansion vase Manual filling pump Pressure & temperature gauge Hot water heater(s) (with temperature safeties) Regulator (for hot water heater(s) Control panel Chimney(s) Electric emergency stop & LP-gas emergency valve Electric cabling & connection box & cables tray

5 HOT VAPORIZER "FEED-ACK"

GFT-060/40/H2. Designed and built According AD-2000 regulation Homologation and branded CE According to the European Directive CE

GFT-060/40/H2. Designed and built According AD-2000 regulation Homologation and branded CE According to the European Directive CE Item 1) TWO THERMAL OIL HEATERS OF 1200 kw EACH 1.1) THERMAL OIL HEATER BODY Brand PIROBLOC Model GFT-060/40/H2 Power 1200 kw Delta Temperature 40 ºC Execution Horizontal Designed and built According AD-2000

More information

BELTEXCO GLOVES 18 PSIG SNG (LPG AIR MIX) PROJECT BY DEA

BELTEXCO GLOVES 18 PSIG SNG (LPG AIR MIX) PROJECT BY DEA BELTEXCO GLOVES 18 MMBTU@15 PSIG SNG (LPG AIR MIX) PROJECT BY DEA Dynamic Engineering & Automation Leader in Energy Technologies Web: www.dea.com.pk Installation, Commissioning and Startup of state of

More information

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents Boiler specifications A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents Burner General: Q. Burner and burner safeguards shall comply with the CGA

More information

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata EKS/HE Refrigerant R410A GWP=2.088 Scroll Compressor Shell & Tube exchanger Axial fan Brazed plate heat exchanger MultiScroll Air-cooled liquid chillers High efficiency Solution B - Base I - Integrata

More information

Waste/Multi Oil Boilers from Flexiheat

Waste/Multi Oil Boilers from Flexiheat Waste/Multi Oil Boilers from Flexiheat At a time of rising fuel costs, the Flexiheat FMOB universal/waste oil boiler range, which can burn nearly all vegetable, animal, conventional and waste oil, will

More information

Performance and safety features of a 2 x cbm LPG-import terminal built in China

Performance and safety features of a 2 x cbm LPG-import terminal built in China Performance and safety features of a 2 x 50.000 cbm LPG-import terminal built in China Dr. Manfred Kuver Christof Fey Li Qin Yi Executive Vice President Tractebel Gas Engineering GmbH Deputy Engineering

More information

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL VS SERIES NH3 STEAM VAPORIZERS Revised March 1997 OPERATION MANUAL CONTENTS PAGE 1. GENERAL................................... 1 Figure 1-1 - VS Series Vaporizer......................... B How to Select

More information

Flange immersion heaters

Flange immersion heaters Flange immersion heaters for ATEX/IECEx hazardous areas or in non-atex version HEATING GASES HEATING LIQUIDS MAINTAINING A CONTINUOUS TEMPERATURE CETAL flange immersion heaters are designed and manufactured

More information

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb) CO 2 Vaporising Atmospheric ASCO CO 2 Vaporiser The atmospheric ASCO CO 2 Vaporiser has been developed to drastically reduce CO 2 vaporisation costs. Ambient air, which is available at no cost, is used

More information

Phillips. HORIZONTAL AND VERTICAL ASSEMBLIES For Ammonia (R-717) and Halocarbon Refrigerants

Phillips. HORIZONTAL AND VERTICAL ASSEMBLIES For Ammonia (R-717) and Halocarbon Refrigerants Phillips REFRIGERATION MECHANICAL PUMP RECIRCULATORS BULLETIN MPR-03E Engineering Data VALVES VESSELS SYSTEMS CONTROLS HORIZONTAL AND VERTICAL ASSEMBLIES For Ammonia (R-717) and Halocarbon Refrigerants

More information

Chemical engineering range - 11/01 MULTI-FUNCTION DISTILLATION DVI/6000. Version presented DVI/6000 PIGNAT S.A.S. Subject to technical modifications

Chemical engineering range - 11/01 MULTI-FUNCTION DISTILLATION DVI/6000. Version presented DVI/6000 PIGNAT S.A.S. Subject to technical modifications Chemical engineering range - 11/01 MULTI-FUNCTION DISTILLATION Version presented 1 Chemical engineering range- 11/01 Technical description Distillation packing column: 1 20L polyethylene feeding tank.

More information

DRYPACK. Protecting installations Energy optimisation. Operating principle. Description. Biogas dehumidification system. Improved profitability.

DRYPACK. Protecting installations Energy optimisation. Operating principle. Description. Biogas dehumidification system. Improved profitability. Protecting installations Energy optimisation Improved profitability Flow rate of conditioned biogas: up to 6 000 Nm 3 /h Biogas efficient waste recovery Operating principle When produced, biogas contains

More information

Application Bulletin. LNG / LPG Facilities FLAME AND GAS DETECTION FOR LNG FACILITIES

Application Bulletin. LNG / LPG Facilities FLAME AND GAS DETECTION FOR LNG FACILITIES FLAME AND GAS DETECTION FOR LNG FACILITIES Liquefied natural gas (LNG) is a generic name for liquefied hydrocarbon gas composed primarily of methane. When natural gas is cooled to approximately -260 F,

More information

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

HYDROCIAT LW R407C. Water cooled chillers USE RANGE Screw compressors CIAT dry direct expansion shell and tubes evaporator HPS equipment (High Power System) cooling or heating Heat recovery ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT

More information

FLAT FLAME AND EXCESS AIR BURNERS

FLAT FLAME AND EXCESS AIR BURNERS FLAT FLAME AND EXCESS AIR BURNERS SIDEWINDER - SW SERIES FEATURES Bulletin E303 rev04 31/01/00 Mixer body: cast iron G2 Plate: cast iron G2 Gas tube: AISI304 Pre-heated air: up to 40 Suitable for different

More information

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version heating for a better future Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version HEATING GASES HEATING LIQUIDS The CETAL-developed Cast-In Circulation Heater Technology

More information

Kälte Klima. Water cooled water chillers from 200 kw to 1550 kw. Screw Compressor LCWX DE 56 01/16 12/13

Kälte Klima. Water cooled water chillers from 200 kw to 1550 kw. Screw Compressor LCWX DE 56 01/16 12/13 Water cooled water chillers from 200 kw to 1550 kw Screw Compressor Serie: Series: Emissione: Issue: LCWX Catalogo: Leaflet: Sostituisce: Supersedes: DE 56 01/16 12/13 Index Identification code Index...

More information

Refrigeration Technology in Building Services Engineering

Refrigeration Technology in Building Services Engineering Unit 70: Unit code: T/600/0459 QCF Level: 3 Credit value: 10 Guided learning hours: 60 Unit aim Refrigeration Technology in Building Services Engineering This unit develops an understanding of the principles,

More information

i-temp MAX Up to 150 C 12 to 360kW

i-temp MAX Up to 150 C 12 to 360kW wi ABOUT THE i-temp RANGE The Max wi collection has been developed to offer a large performance range by means of modular design with various combinations of heating and cooling elements which cater for

More information

Silhouette. Feedwater Heater. Boiler Feedwater

Silhouette. Feedwater Heater. Boiler Feedwater Roth Roth Low Low Silhouette Silhouette TRAY DEAERATORS Boiler Boiler Feedwater Feedwater Heater Heater Capacities Capacities to to 50,000 50,000 lb/hr lb/hr Model RDTV-150-5-1-2 vertical tray type deaerator

More information

Air-Drying Device. PROTEGO LA and LA/V. Function and Description LA/V. Figure 2 Figure 3

Air-Drying Device. PROTEGO LA and LA/V. Function and Description LA/V. Figure 2 Figure 3 Function and Description PROTEGO Air-drying device of types LA or LA/V is used when suction air must be dried for atmospheric venting of storage tanks where only little or no humidity is allowed to get

More information

Condensate Recovery and Return System SDR A

Condensate Recovery and Return System SDR A Condensate Recovery and Return System SDR A Condensate tank of rectangular design type SDR A with high-pressure centrifugal pump(s) installed next to the tank Condensate tanks are used to collect the condensate

More information

Moss MOSS TRAY DEAERATOR ECONOMICAL INDUSTRIAL DEAERATOR SYSTEMS

Moss MOSS TRAY DEAERATOR ECONOMICAL INDUSTRIAL DEAERATOR SYSTEMS Moss MOSS TRAY DEAERATOR ECONOMICAL INDUSTRIAL DEAERATOR SYSTEMS MOSS TRAY DEAERATOR DESIGNS WHY DEAERATE? Removal of corrosive oxygen and carbon dioxide from boiler feedwater Reduction in the use of oxygen

More information

Technical Discussion on

Technical Discussion on Technical Discussion on Closed drain system Knock Out Drum system Common venting system Water Seal Drum Remote Ignition system Flare system By D DAS Need of CD, KOD,Water Seal Drum,Remote Ignition system

More information

CRU-S Series Stainless Steel Condensate Recovery Unit

CRU-S Series Stainless Steel Condensate Recovery Unit IM-UK-CRU-S UK Issue 1 CRU-S Series Stainless Steel Condensate Recovery Unit 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Storage, shutdown and equipment protection

More information

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING

More information

Air-Cooling Evaporators

Air-Cooling Evaporators Air-Cooling Evaporators Types of construction Circuit Configurations Methods of Refrigerant Feed Methods of Air Circulation Methods of Defrost Type of Construction Bare tube Finned Tube Plate-surface Bare

More information

BuildingName The Description of the Project P DOCUMENTS

BuildingName The Description of the Project P DOCUMENTS ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION

More information

MSMCR. Counter-Rotating Blenders. I Application. I Principle of operation

MSMCR. Counter-Rotating Blenders. I Application. I Principle of operation MS I Application Counter-rotating blenders are used for mixing and homogenizing dispersed products at a controlled temperature with an optimum performance, regardless of the product viscosity. These units

More information

Construction Heat CH-02 (up to 400,000 BTU) Record of Training Curriculum Document

Construction Heat CH-02 (up to 400,000 BTU) Record of Training Curriculum Document Introduction: This TSSA document defines the required training curriculum content for CH-02 Record of Training programs under Ontario Regulation 215/01(Fuel Industry Certificates). Ontario Training Providers

More information

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance Installation Operation Commissioning Maintenance HOT AIR GENERATOR WITH GAS BURNER GGS NA11.45 A 06-2011 04-2011 CONTENTS 1. DESCRIPTION OF THE UNIT 2. INSTALLATION & CONNECTION 3. COMMISSIONING 4. CARE

More information

Intelligent Refrigeration Solutions

Intelligent Refrigeration Solutions Intelligent Refrigeration Solutions Stop Check Valves Suitable for all common refrigerants including R-717 (Ammonia), R-134a and others Temperature Range: -50 F to 240 F (-46 C to +116 C) Temperature Below:

More information

DISCALDIRT deaerator-dirt separator

DISCALDIRT deaerator-dirt separator DISLDIR deaerator-dirt separator 6 series REDIED ISO 900 M 6 ISO 900 No. 000 0/ G replaces dp 0/0 G unction Deaerators-dirt separators are used to continuously eliminate the air and dirt contained in the

More information

Submittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating

Submittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating The High Efficiency AYF60-119 units are 2 module appliances; each AYF is

More information

NKW. Heater series HEATERS

NKW. Heater series HEATERS HEATERS Heater series Applications Duct electrical heaters are designed for heating of supply air in rectangular ventilating system and are applicable in supply or supply and exhaust units. Design The

More information

Water chillers water/water type SIGMA Technical information manual

Water chillers water/water type SIGMA Technical information manual Water chillers water/water type SIGMA Technical information manual 2 INDEX Technical features 1 Versions 3 Accessory versions 4 Technical data 7 Electrical data 11 Cooling capacity 12 Heating capacity

More information

Technical Bulletin MODELS AFFECTED SW3, SW3T SW4, SW4T SW5, SW5T

Technical Bulletin MODELS AFFECTED SW3, SW3T SW4, SW4T SW5, SW5T Technical Bulletin BULLETIN NO. 20606 DATE: February 6, 2006 PRODUCT: SW Series FROM: Technical Service Department TITLE: Vent Proving Pressure Switch MODELS AFFECTED SW3, SW3T SW4, SW4T SW5, SW5T SITUATION

More information

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. Pipe and Pipe Fittings. B. Air compressor. C. Air receiver and accessories. D. Aftercooler. E. Refrigerated air dryer. F. Pressure reducing station. 1.02 RELATED

More information

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the

More information

OPERATION MANUAL 2000 RE SERIES LP-GAS ELECTRIC VAPORIZERS

OPERATION MANUAL 2000 RE SERIES LP-GAS ELECTRIC VAPORIZERS 2000 RE SERIES LP-GAS ELECTRIC VAPORIZERS OPERATION MANUAL CONTENTS PAGE 1. GENERAL................................... 1 Figure 1-1 - RE Series Vaporizer......................... B How to Select an Electric

More information

Condensate Recovery and Return System SDR A

Condensate Recovery and Return System SDR A Condensate Recovery and Return System SDR A Condensate tank of rectangular design type SDR A with high-pressure centrifugal pump(s) installed next to the tank condensate coming from steam users or flash

More information

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE INSTRUCTION MANUAL INSTALLATION AND SERVICING AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE About this manual These installation and maintenance instructions contain important information

More information

Brasch Hazardous Location Unit Heaters

Brasch Hazardous Location Unit Heaters Brasch Hazardous Location Unit Heaters BHUH Features Designed for rugged industrial applications in hazardous locations where the possibility of explosion or fire exists due to the presence of certain

More information

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED FUEL OIL DAY TANKS SST Series - Engineering Submittal SST Series - Advanced Line Day Tanks Construction: UL 142 aboveground steel tank all seam welded, square, atmospheric tank of heavy gauge steel with

More information

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS INDEECO Circulation Heaters are designed to provide years of trouble free operation if properly installed and maintained. Please read and follow these instructions for installing and maintaining the heater.

More information

Water Bath LPG Vaporizers with Smart Liquid Carryover Protection

Water Bath LPG Vaporizers with Smart Liquid Carryover Protection Alternate Energy Systems, Inc. A Corporation devoted to Energy-Oriented Needs Water Bath LPG Vaporizers with Smart Liquid Carryover Protection 08-Series 05-Series WB-458 in standard Configuration WB-2505

More information

15B Cast Iron Gas Fired Boilers For Forced Hot Water

15B Cast Iron Gas Fired Boilers For Forced Hot Water Models 5B05FE 5B070FE 5B0FE 5B0FE 5B5FE 5B70FE 5B5FE 5B5FE 5B5FE 5B Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS Ordering Instructions Order Parts through your nearest

More information

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass Product of Quality Best Performance Ball Float Controlled Steam Traps Auto Drain Traps Float Valve Air Vent Valves Feed Control Valve Drain Control Valve Thermo Dynamic(TD) Trap Safety Valve Condensate

More information

Installation and Operation of AST Equipment. Presenter: Steve Allwein Northeast Regional Sales Manager Morrison Bros. Co.

Installation and Operation of AST Equipment. Presenter: Steve Allwein Northeast Regional Sales Manager Morrison Bros. Co. Installation and Operation of AST Equipment Presenter: Steve Allwein Northeast Regional Sales Manager Morrison Bros. Co. HISTORY Morrison Bros. Co. Then Founded in 1855 Located in Dubuque, Iowa Originally

More information

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler HIGH POWER VICTRIX PRO 2 ErP High power, wall-hung condensation boiler MAIN INDEX INDEX 1 VICTRIX PRO 35-55 2 ErP SPECIFICATIONS...5 2 VICTRIX PRO 80-100-120 2 ErP SPECIFICATIONS...6 3 VICTRIX PRO 35-55

More information

Solar water heating system

Solar water heating system Solar water heating system Perhaps the most popular application of solar systems is for domestic water heating. The popularity of these systems is based on the fact that relatively simple systems are involved

More information

.2 Section Waste Management and Disposal.

.2 Section Waste Management and Disposal. Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

PIPING SYSTEM EQUIPMENTS

PIPING SYSTEM EQUIPMENTS PIPING SYSTEM EQUIPMENTS Introduction Equipments are devices that provide power, process and store materials. Equipments in piping systems depend on the specific industries using them. Specialized equipment

More information

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. General: 1. To obtain maintenance and repair standards for boiler burners (Section 15555A) and boiler tubes (Section 15555B), contact the DPS Project

More information

OWNER S MANUAL LOW-POWER SCREW-IN AND FLANGE-MOUNTED IMMERSION HEATERS (MAXIMUM 3 PINS)

OWNER S MANUAL LOW-POWER SCREW-IN AND FLANGE-MOUNTED IMMERSION HEATERS (MAXIMUM 3 PINS) 1/5 VULCANIC S.A. - 48, rue Louis Ampère Zone Industrielle des Chanoux - F 93330 NEUILLY / MARNE (France) Tél. (33) 01.49.44.49.20 - Fax (33) 01.49.44.49.41 OWNER S MANUAL LOW-POWER SCREW-IN AND FLANGE-MOUNTED

More information

BINDER Scientific Product Catalog

BINDER Scientific Product Catalog BINDER Scientific Product Catalog 36 Vacuum drying ovens Vacuum drying ovens 37 VD VDL VDL EX-Zone 2 Absolutely reliable drying Drying with no residues, no danger of incrustation, no oxidation all under

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a Air-Cooled Variable Speed Drive Screw Chillers Super Efficient Super Quiet Cooling Capacity Range 540-1405 kw R134a World s first low sound Air-Cooled variable speed drive screw chiller The recognition

More information

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier OM001 Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier These operating and maintenance instructions are for standard semi-storage calorifiers (vessels fitted with

More information

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program. 15682 CENTRIFUGAL WATER CHILLERS ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 236416 An optional

More information

INDIRECT SYSTEM FOR FROST LOCATIONS

INDIRECT SYSTEM FOR FROST LOCATIONS SOLAR WATER HEATING INDIRECT SYSTEM FOR FROST LOCATIONS EFFICIENT USE OF NATURAL SOLAR ENERGY FROM THE DOMESTIC SOLAR WATER HEATERS WITH SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES Solar Water Heaters

More information

Water Bath. LPG Vaporizers with Smart Liquid Carryover Protection

Water Bath. LPG Vaporizers with Smart Liquid Carryover Protection ISO9001:2008 REGISTERED Alternate Energy Systems, Inc. A Corporation devoted to Energy-Oriented Needs Water Bath UPDATE March 2015 LPG Vaporizers with Smart Liquid Carryover Protection 08-Series 05-Series

More information

5 HEAT EXCHANGER PROCESS PLANT COMPONENTS. P 305 e.3. Copyright 2007, QVF Engineering GmbH. All rights reserved.

5 HEAT EXCHANGER PROCESS PLANT COMPONENTS. P 305 e.3. Copyright 2007, QVF Engineering GmbH. All rights reserved. 5 HEAT EXCHANGER PROCESS PLANT COMPONENTS P 305 e.3 Copyright 7, QVF Engineering GmbH. All rights reserved. Introduction QVF heat exchangers provide the optimum solution for every requirement encountered

More information

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make. All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing

More information

BFM Balanced flue commercial water heater

BFM Balanced flue commercial water heater Balanced flue commercial water heater BFM 30/50/80/100/120 ide range of balanced fanned flue room-sealed water heaters for installation in almost any location Improved efficiency Removable control column

More information

Air/water - Heat pumps

Air/water - Heat pumps Air/water - Heat pumps Installation of a NIBE air/water heat pump can lead to your energy consumption for heating being reduced by up to 50%, in comparison to conventional heating systems. Areas of Use

More information

USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater

USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater Contents Section Page Major Components... 2 1 About Our Manual... 2 2 Refractory Handling...

More information

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE PFS APPROVED FOR NATURAL GAS OR PROPANE GAS Z21.50-2014 If your plans do not allow for the venting system as outlined previously in the installing chimney/vent

More information

Centrifugal Pumps with Shaft Sealing and Priming Stage Type HZS / HZSA

Centrifugal Pumps with Shaft Sealing and Priming Stage Type HZS / HZSA Centrifugal Pumps with Shaft Sealing and Priming Stage Type HZS / HZSA General The selfpriming multistage DICKOW-centrifugal pump is designed for handling hydrocarbons and other volatile liquids. Applications

More information

Submittal Data GAHP Line W LB Series Ground Source Gas Fired Absorption Heat Pump Heating and Cooling

Submittal Data GAHP Line W LB Series Ground Source Gas Fired Absorption Heat Pump Heating and Cooling GAHP Line W LB Series Ground Source Gas Fired Absorption Heat Pump Heating and Cooling GAHP is the acronym for Gas Absorption Heat Pump. The GAHP-W is a high efficiency water-cooled heat pump, utilizing

More information

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw TECHNICAL INSTRUCTIONS CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw CHG 1 CHG 1 8. kw. kw.7 kw 1. kw April 7 19 - GB - 2 MARKING This product marked conforms to the essential

More information

Circulation Heaters Selection Guidelines

Circulation Heaters Selection Guidelines Selection Guidelines Selecting a Circulation Heater Application Factors Corrosion Policy Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation

More information

Installing, Operating & Maintaining MUNCHKIN HIGH EFFICIENCY HEATER with the 925 Controller

Installing, Operating & Maintaining MUNCHKIN HIGH EFFICIENCY HEATER with the 925 Controller Installing, Operating & Maintaining MUNCHKIN HIGH EFFICIENCY HEATER with the 925 Controller WARNING If the information in this manual is not followed exactly, a fire or explosion may result causing property

More information

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function Anti-condensation recirculation and distribution unit 8 series ACCREDITED ISO 900 FM 654 ISO 900 No. 000 CALEFFI 04/4 GB Replaces dp 04/ GB GB Function The anti-condensation recirculation and distribution

More information

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo INSTALLATION, OPERATION AND MAINTENANCE Ariterm Vedo CONTENTS General...3 Installation...4-5 Laddomat 21 Connection diagram...6 Temperature control valve...7 About burning wood...8 Operation...9-11 Service

More information

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com Tray ST5 Pressurized and Atmospheric Deaerators Tray Type Deaerator Pressurized.005 cc/liter COUNTER FLOW TRAY design provides guaranteed removal of all dissolved oxygen in excess of.005 cc/liter from

More information

Installing, Operating & Maintaining MUNCHKIN HIGH EFFICIENCY 399M COMMERCIAL BOILER

Installing, Operating & Maintaining MUNCHKIN HIGH EFFICIENCY 399M COMMERCIAL BOILER Installing, Operating & Maintaining MUNCHKIN HIGH EFFICIENCY 399M COMMERCIAL BOILER WARNING If the information in this manual is not followed exactly, a fire or explosion may result causing property damage,

More information

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.00 kw -. kw PHRT.0 kw /.0 kw

More information

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions Pre-assembled skid system Back-to-Back heater models, SNA & SNAR High Flow Demand Safety Shower Applications 216-288 kw (737,000-983,000 BTUs) Temperature overshoot purge system NEMA 4 enclosure standard

More information

MFP14 Automatic pumps for condensate and other industrial fluids

MFP14 Automatic pumps for condensate and other industrial fluids MFP14 Automatic pumps for condensate and other industrial fluids Effective condensate management... an essential part of any steam plant If energy requirements are to be kept to a minimum, then efficient

More information

Operation Manual. WARNING!!! Read Before Using RES SERIES - LIQUID PETROLEUM GAS ELECTRIC VAPORIZERS. Engineering and Equipment Manufacturing

Operation Manual. WARNING!!! Read Before Using RES SERIES - LIQUID PETROLEUM GAS ELECTRIC VAPORIZERS. Engineering and Equipment Manufacturing Engineering and Equipment Manufacturing Operation Manual RES SERIES - LIQUID PETROLEUM GAS ELECTRIC VAPORIZERS WARNING!!! Read Before Using This equipment is designed for use with LP-Gas, flammable fuels

More information

FE1 Explosion-Proof Electric Air Heaters

FE1 Explosion-Proof Electric Air Heaters Explosion-Proof Electric Air Heaters The heater core assembly is contained in a sturdy, epoxy-coated, 14-gauge steel cabinet which also carries the motor and fan assembly. Adjustable louvers allow directional

More information

GASEOUS HYDROGEN SYSTEMS

GASEOUS HYDROGEN SYSTEMS CHAPTER 7 GASEOUS HYDROGEN SYSTEMS SECTION 701 GENERAL 701.1 Scope. The installation of gaseous hydrogen systems shall comply with this chapter and Chapters 30 and 35 of the Fire Compressed gases shall

More information

Installation, Operation and Maintenance Instructions for Electric Storage Calorifier

Installation, Operation and Maintenance Instructions for Electric Storage Calorifier OM004 Installation, Operation and Maintenance Instructions for Electric Storage Calorifier The operating and maintenance instructions contained within this package are for standard electric storage calorifiers

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status: IECEx INE 10.0013X Current

More information

SECTION DOMESTIC WATER HEATERS

SECTION DOMESTIC WATER HEATERS SECTION 223500 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

Repair instruction and handling for Isobutane (R600a) refrigerant.

Repair instruction and handling for Isobutane (R600a) refrigerant. Repair instruction and handling for Isobutane (R600a) refrigerant. Refrigerant Isobutane R600a Isobutane is a colourless gas with a slight odour. It is also known as cigarette lighter fuel and camping

More information

BOILER HOUSE PRODUCTS GMS

BOILER HOUSE PRODUCTS GMS GMS BOILER HOUSE PRODUCTS Contents Page 2 Introduction 3 Condensate Pumpsets 6 Blowdown Vessels 8 Boiler Feed Tanks Page 10 Chemical Dosing Pots 11 Vent Heads 11 De-Aerator Heads Introduction to Boiler

More information

Installing, Operating & Maintaining MUNCHKIN HIGH EFFICIENCY HEATER with the 925 Controller

Installing, Operating & Maintaining MUNCHKIN HIGH EFFICIENCY HEATER with the 925 Controller Installing, Operating & Maintaining MUNCHKIN HIGH EFFICIENCY HEATER with the 925 Controller WARNING If the information in this manual is not followed exactly, a fire or explosion may result causing property

More information

OPTIBAR DP 7060 Supplementary Instructions

OPTIBAR DP 7060 Supplementary Instructions OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,

More information

HEAT TRACING FOR THE REFRIGERATION INDUSTRY

HEAT TRACING FOR THE REFRIGERATION INDUSTRY Thermon South Africa (Pty) Ltd. HEAT TRACING FOR THE REFRIGERATION INDUSTRY THERMON TRACE HEATING CABLES THERMON self regulating trace heaters cover the complete range of applications from frost protection

More information

Permutadores de calor

Permutadores de calor refrigerados a água - Hypercool Aftercoolers can be installed immediately downstream of compressors or blowers in order to remove over 80 % of the condensate. Their function is to protect the entire compessed

More information

ULTRA-SAFE Explosion-proof Duct Heaters

ULTRA-SAFE Explosion-proof Duct Heaters Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer

More information

geothermal march 2011

geothermal march 2011 geothermal march 2011 General information Office hours: Monday to Friday 8.30am - 5.00pm. Prices: Prices are exclusive of VAT, and are subject to change without notice. All prices displayed are recognised

More information

MFP14 Automatic pumps. for condensate and other industrial fluids

MFP14 Automatic pumps. for condensate and other industrial fluids MFP1 Automatic pumps for condensate and other industrial fluids Effective condensate management... an essential part of any steam plant If energy requirements are to be kept to a minimum, then efficient

More information

KDE. PRESSURIZED STAINLESS STEEL CONDENSING BOILER FROM 124 kw TO 2160 kw

KDE. PRESSURIZED STAINLESS STEEL CONDENSING BOILER FROM 124 kw TO 2160 kw KDE PRESSURIZED STAINLESS STEEL CONDENSING BOILER FROM 124 kw TO 2160 kw Features Large water content condensing boiler for pressure jet modulating gas burners. 12 models from 124 to 2160 kw Very high

More information

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION STEAM TRAP CHECKING Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION Steam Traps Review - Mechanical Traps Float Inverted

More information

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C ALKON 50 C ALKON 70 C WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) OUTPUT RANGE from 50 to 560 kw (in battery) WORKING TEMPERATURE no limit on

More information

Auto Service Test Review. For the Most Effective Personal Review, Match the Following Questions to the On Line Study Guide Multimedia

Auto Service Test Review. For the Most Effective Personal Review, Match the Following Questions to the On Line Study Guide Multimedia Auto Service Test Review For the Most Effective Personal Review, Match the Following Questions to the On Line Study Guide Multimedia Auto Service Test Review Test #3 73 Questions from: Chapters 39 & 40

More information

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM BURNERS/ FLARES VAREC BIOGAS 4W Series WASTE GAS BURNER & IGNITION SYSTEM The Varec Biogas 4W Series Waste Gas Burner is a highly reliable flare and ignition system ideal for use in burning excess biogas.

More information